Buses Y Discos

Embed Size (px)

Citation preview

  • 8/7/2019 Buses Y Discos

    1/19

    BUS IDE

    IDE = Integrated Drive Electronis.

    Denominacin: 40 PIN IDC Macho.

    40 PIN IDC Hembra.

    En el disco y controlador (Macho)

    En el Cable (Hembra)

    Pin Name Dir Description

    1 /RESET Reset

    2 GND Ground

    3 DD7 Data 7

    4 DD8 Data 8

    5 DD6 Data 66 DD9 Data 9

    7 DD5 Data 5

    8 DD10 Data 10

    9 DD4 Data 4

    10 DD11 Data 11

    11 DD3 Data 3

    12 DD12 Data 12

    13 DD2 Data 2

    14 DD13 Data 13

    15 DD1 Data 1

    16 DD14 Data 14

    17 DD0 Data 0

    18 DD15 Data 15

    19 GND Ground

  • 8/7/2019 Buses Y Discos

    2/19

    20 KEY - Key

    21 n/c - Not connected

    22 GND Ground

    23 /IOW Write Strobe

    24 GND Ground

    25 /IOR Read Strobe

    26 GND Ground

    27 IO_CH_RDY

    28 ALE Address Latch Enable

    29 n/c - Not connected

    30 GND Ground

    31 IRQR Interrupt Request

    32 /IOCS16 ? IO ChipSelect 1633 DA1 Address 1

    34 n/c - Not connected

    35 DA0 Address 0

    36 DA2 Address 2

    37 /IDE_CS0 (1F0-1F7)

    38 /IDE_CS1 (3F6-3F7)

    39 /ACTIVE Led driver

    40 GND Ground

  • 8/7/2019 Buses Y Discos

    3/19

    SCSI

    SCSI=Small Computer System Interface.

    CENTRONICS 50

    Denominacin: 50 PIN CENTRONICS Hembra.

    50 PIN CENTRONICS Macho.

    Lado del Controlador y Dispositivos(Hembra)

    Lado del Cable (Macho)

    SINGLE-ENDED

    N de Pin Nombre Dir Descripcin

    1-25 GND Ground

    26 DB0 Data Bus 0

    27 DB1 Data Bus 1

    28 DB2 Data Bus 2

    29 DB3 Data Bus 3

    30 DB4 Data Bus 4

    31 DB5 Data Bus 5

    32 DB6 Data Bus 6

    33 DB7 Data Bus 7

    34 PARITY Data Parity (odd Parity)

    35 GND Ground

    36 GND Ground

  • 8/7/2019 Buses Y Discos

    4/19

    37 GND Ground

    38 TMPWR Termination Power

    39 GND Ground

    40 GND Ground

    41 /ATN Attention

    42 n/c - Not connected

    43 /BSY Busy

    44 /ACK Acknowledge

    45 /RST Reset

    46 /MSG Message

    47 /SEL Select

    48 /C/D Control/Data

    49 /REQ Request50 /I/O Input/Output

    DIFERENCIAL

    N de Pin Nombre Dir Descripcin

    01 GND Ground

    02 +DB0 +Data Bus 0

    03 +DB1 +Data Bus 1

    04 +DB2 +Data Bus 2

    05 +DB3 +Data Bus 3

    06 +DB4 +Data Bus 4

    07 +DB5 +Data Bus 5

    08 +DB6 +Data Bus 6

    09 +DB7 +Data Bus 7

    10 +DBP +Data Bus Parity (odd Parity)

    11 DIFFSENS ? ???12 res - Reserved

    13 TERMPWR Termination Power

    14 res - Reserved

    15 +ATN +Attention

    16 GND Ground

  • 8/7/2019 Buses Y Discos

    5/19

    17 +BSY +Bus is busy

    18 +ACK +Acknowledge

    19 +RST +Reset

    20 +MSG +Message

    21 +SEL +Select

    22 +C/D +Control or Data

    23 +REQ +Request

    24 +I/O +In/Out

    25 GND Ground

    26 GND Ground

    27 -DB0 -Data Bus 0

    28 -DB1 -Data Bus 1

    29 -DB2 -Data Bus 230 -DB3 -Data Bus 3

    31 -DB4 -Data Bus 4

    32 -DB5 -Data Bus 5

    33 -DB6 -Data Bus 6

    34 -DB7 -Data Bus Parity7

    35 -DBP -Data Bus Parity (odd Parity)

    36 GND Ground

    37 res - Reserved

    38 TERMPWR Termination Power

    39 res - Reserved

    40 -ATN -Attention

    41 GND Ground

    42 -BSY -Bus is busy

    43 -ACK -Acknowledge

    44 -RST -Reset

    45 -MSG -Message

    46 -SEL -Select

    47 -C/D -Control or Data

    48 -REQ -Request

    49 -I/O -In/Out

    50 GND Ground

  • 8/7/2019 Buses Y Discos

    6/19

    D-SUB 25

    Denominacin: 25 PIN D-SUB Hembra.

    25 PIN D-SUB Macho.

    Lado del Controlador (Hembra)

    Lado del Cable (Macho)

    Pin Name Dir Description

    1 /REQ Request

    2 /MSG Message

    3 I/O Input/Output

    4 /RST Reset

    5 /ACK Acknowledge

    6 BSY Busy

    7 GND Ground

    8 DB0 Data Bus 0

    9 GND Ground

    10 DB3 Data Bus 3

    11 DB5 Data Bus 5

    12 DB6 Data Bus 6

    13 DB7 Data Bus 7

    14 GND Ground

    15 C/D Control/Data

    16 GND Ground

    17 /ATN Attention

    18 GND Ground

    19 /SEL Select

    20 PARITY Data Parity

  • 8/7/2019 Buses Y Discos

    7/19

  • 8/7/2019 Buses Y Discos

    8/19

    09 +DB3 +Data Bus 3

    10 -DB3 -Data Bus 3

    11 +DB4 +Data Bus 4

    12 -DB4 -Data Bus 4

    13 +DB5 +Data Bus 5

    14 -DB5 -Data Bus 5

    15 +DB6 +Data Bus 6

    16 -DB6 -Data Bus 6

    17 +DB7 +Data Bus 7

    18 -DB7 -Data Bus Parity7

    19 +DBP +Data Bus Parity (odd Parity)

    20 -DBP -Data Bus Parity (odd Parity)

    21 DIFFSENS ? ???22 GND Ground

    23 res - Reserved

    24 res - Reserved

    25 TERMPWR Termination Power

    26 TERMPWR Termination Power

    27 res - Reserved

    28 res - Reserved

    29 +ATN +Attention

    30 -ATN -Attention

    31 GND Ground

    32 GND Ground

    33 +BSY +Bus is busy

    34 -BSY -Bus is busy

    35 +ACK +Acknowledge

    36 -ACK -Acknowledge

    37 +RST +Reset

    38 -RST -Reset

    39 +MSG +Message

    40 -MSG -Message

    41 +SEL +Select

    42 -SEL -Select

    43 +C/D +Control or Data

  • 8/7/2019 Buses Y Discos

    9/19

    44 -C/D -Control or Data

    45 +REQ +Request

    46 -REQ -Request

    47 +I/O +In/Out

    48 -I/O -In/Out

    49 GND Ground

    50 GND Ground

    SINGLE-ENDED

    Pin Name Dir Description

    2 DB0 Data Bus 0

    4 DB1 Data Bus 1

    6 DB2 Data Bus 2

    8 DB3 Data Bus 3

    10 DB4 Data Bus 4

    12 DB5 Data Bus 5

    14 DB6 Data Bus 6

    16 DB7 Data Bus 7

    18 PARITY Data Parity (odd Parity)

    20 GND Ground

    22 GND Ground

    24 GND Ground

    26 TMPWR Termination Power

    28 GND Ground

    30 GND Ground

    32 /ATN Attention

    34 GND Ground

    36 /BSY Busy38 /ACK Acknowledge

    40 /RST Reset

    42 /MSG Message

    44 /SEL Select

    46 /C/D Control/Data

  • 8/7/2019 Buses Y Discos

    10/19

    48 /REQ Request

    50 /I/O Input/Output

  • 8/7/2019 Buses Y Discos

    11/19

    SCSI II

    Denominacin: 50 PIN HI-DENSITY D-SUB Hembra.

    50 PIN HI-DENSITY D-SUB Macho.

    Lado del Controlador y Dispositivos (Hembra)

    Lado del Cable (Macho)

    SINGLE-ENDED

    N de Pin Nombre Dir Descripcin

    1-25 GND Ground

    26 DB0 Data Bus 0

    27 DB1 Data Bus 1

    28 DB2 Data Bus 2

    29 DB3 Data Bus 3

    30 DB4 Data Bus 4

    31 DB5 Data Bus 5

    32 DB6 Data Bus 6

    33 DB7 Data Bus 7

    34 PARITY Data Parity (odd Parity)

    35 GND Ground

    36 GND Ground

    37 GND Ground

    38 TMPWR Termination Power

    39 GND Ground

    40 GND Ground

    41 /ATN Attention

    42 n/c - Not connected

    43 /BSY Busy

  • 8/7/2019 Buses Y Discos

    12/19

  • 8/7/2019 Buses Y Discos

    13/19

    24 +I/O +In/Out

    25 GND Ground

    26 GND Ground

    27 -DB0 -Data Bus 0

    28 -DB1 -Data Bus 1

    29 -DB2 -Data Bus 2

    30 -DB3 -Data Bus 3

    31 -DB4 -Data Bus 4

    32 -DB5 -Data Bus 5

    33 -DB6 -Data Bus 6

    34 -DB7 -Data Bus Parity7

    35 -DBP -Data Bus Parity (odd Parity)

    36 GND Ground37 res - Reserved

    38 TERMPWR Termination Power

    39 res - Reserved

    40 -ATN -Attention

    41 GND Ground

    42 -BSY -Bus is busy

    43 -ACK -Acknowledge

    44 -RST -Reset

    45 -MSG -Message

    46 -SEL -Select

    47 -C/D -Control or Data

    48 -REQ -Request

    49 -I/O -In/Out

    50 GND Ground

  • 8/7/2019 Buses Y Discos

    14/19

    SCSI III

    Denominacin: 68 PIN HI-DENSITY D-SUB Hembra.

    68 PIN HI-DENSITY D-SUB Macho.

    Lado del Controlador y Dispositivos (Hembra)

    Lado del Cable (Macho)

    SINGLE-ENDED

    Pin Name Dir Description

    1-16 GND Ground

    17 TERMPWR Termination Power

    18 TERMPWR Termination Power

    19 res reserved

    20-34 GND Ground

    35 DB12 Data Bus 12

    36 DB13 Data Bus 13

    37 DB14 Data Bus 14

    38 DB15 Data Bus 15

    39 DPB1 Data Parity (odd Parity)

    40 DB0 Data Bus 0

    41 DB1 Data Bus 1

    42 DB2 Data Bus 2

    43 DB3 Data Bus 3

    44 DB4 Data Bus 4

    45 DB5 Data Bus 5

    46 DB6 Data Bus 6

  • 8/7/2019 Buses Y Discos

    15/19

    47 DB7 Data Bus 7

    48 DPB Data Parity (odd Parity)

    49 GND Ground

    50 GND Ground

    51 TERMPWR Termination Power

    52 TERMPWR Termination Power

    53 res reserved

    54 GND Ground

    55 /ATN Attention

    56 GND Ground

    57 /BSY Busy

    58 /ACK Acknowledge

    59 /RST Reset60 /MSG Message

    61 /SEL Select

    62 /C/D Control/Data

    63 /REQ Request

    64 /I/O Input/Output

    65 DB8 Data Bus 8

    66 DB9 Data Bus 9

    67 DB10 Data Bus 10

    68 DB11 Data Bus 11

    DIFERENCIAL

    Pin Name Dir Description

    1 +DB12 Data Bus 12

    2 +DB13 Data Bus 13

    3 +DB14 Data Bus 144 +DB15 Data Bus 15

    5 +DPB1 Data Parity (odd Parity)

    6 GND Ground

    7 +DB0 Data Bus 0

    8 +DB1 Data Bus 1

  • 8/7/2019 Buses Y Discos

    16/19

    9 +DB2 Data Bus 2

    10 +DB3 Data Bus 3

    11 +DB4 Data Bus 4

    12 +DB5 Data Bus 5

    13 +DB6 Data Bus 6

    14 +DB7 Data Bus 7

    15 +DPB Data Parity (odd Parity)

    16 DIFFSENSE ? Diff Sense?

    17 TERMPWR Termination Power

    18 TERMPWR Termination Power

    19 res reserved

    20 +ATN Attention

    21 GND Ground22 +BSY Busy

    23 +ACK Acknowledge

    24 +RST Reset

    25 +MSG Message

    26 +SEL Select

    27 +C/D Control/Data

    28 +REQ Request

    29 +I/O Input/Output

    30 GND Ground

    31 +DB8 Data Bus 8

    32 +DB9 Data Bus 9

    33 +DB10 Data Bus 10

    34 +DB11 Data Bus 11

    35 -DB12 Data Bus 12

    36 -DB13 Data Bus 13

    37 -DB14 Data Bus 14

    38 -DB15 Data Bus 15

    39 -DPB1 Data Parity (odd Parity)

    40 GND Ground

    41 -DB0 Data Bus 0

    42 -DB1 Data Bus 1

    43 -DB2 Data Bus 2

  • 8/7/2019 Buses Y Discos

    17/19

    44 -DB3 Data Bus 3

    45 -DB4 Data Bus 4

    46 -DB5 Data Bus 5

    47 -DB6 Data Bus 6

    48 -DB7 Data Bus 7

    49 -DPB Data Parity (odd Parity)

    50 GND Ground

    51 TERMPWR Termination Power

    52 TERMPWR Termination Power

    53 res reserved

    54 -ATN Attention

    55 GND Ground

    56 -BSY Busy57 -ACK Acknowledge

    58 -RST Reset

    59 -MSG Message

    60 -SEL Select

    61 -C/D Control/Data

    62 -REQ Request

    63 -I/O Input/Output

    64 GND Ground

    65 -DB8 Data Bus 8

    66 -DB9 Data Bus 9

    67 -DB10 Data Bus 10

    68 -DB11 Data Bus 11

  • 8/7/2019 Buses Y Discos

    18/19

    UNIDAD 3.5"

    Denominacin: 34 PIN IDC Macho.

    34 PIN IDC Hembra.

    Lado de la Unidad y la Placa (Macho)

    En el Cable (Hembra)

    Pin Name Dir Description

    2 /REDWC Density Select

    4 n/c Reserved

    6 n/c Reserved

    8 /INDEX Index

    10 /MOTEA Motor Enable A12 /DRVSB Drive Sel B

    14 /DRVSA Drive Sel A

    16 /MOTEB Motor Enable B

    18 /DIR Direction

    20 /STEP Step

    22 /WDATE Write Data

    24 /WGATE Floppy Write Enable

    26 /TRK00 Track 0

    28 /WPT Write Protect

    30 /RDATA Read Data

    32 /SIDE1 Head Select

    34 /DSKCHG Disk Change

  • 8/7/2019 Buses Y Discos

    19/19

    La interfaz Serial-ATA

    Tabla 2

    Pin Designacin

    S1 G.

    S2 HT+ / DR+

    S3 HT- / DR-

    S4 G.

    S5 HR+ / DT+

    S6 HR- / DT-

    S7 G.

    Nomenclatura:

    HT+, HT-. Par de sealesdiferenciales de transmisin del ladodel host ("Host Transmitter").

    HR+, HR- dem de recepcin ("HostReceiver").

    DT+ y DT- par de sealesdiferenciales de transmisin del ladodel dispositivo ("Device Transmitter").

    DR+, DR-. dem de recepcin("Device Receiver").

    G. Tierra ("Ground").