Bulletin of the JSME Journal of Biomechanical Science and Engineering Vol.12, No.3, 2017 © 2017 The Japan Society of Mechanical Engineers J-STAGE Advance Publication date: 21 February, 2017 Paper No.16-00267 [DOI: 10.1299/jbse.16-00267] Demineralization of cortical bone for improvement of Charpy impact fracture characteristics Kazuhiro FUJISAKI*, Ayumi HASEGAWA*, Hiroya YOKOYAMA* and Kazuhiko SASAGAWA* * Department of Intelligent Machines and System Engineering, Hirosaki University 3, Bunkyo-cho, Hirosaki, Aomori, 0368561, Japan E-mail: [email protected] Abstract Bone tissue is a composite structure of apatite particles distributed in collagen fibril matrix on a nano-size scale. Mechanical properties of cortical bone are determined by the apatite-collagen composition. The amount and specific orientation of apatite crystals strongly affect the mechanical properties of macroscopic bone tissue such as anisotropic elastic modulus and fracture toughness. The progression of mineralization with tissue aging results in a reduction of fracture toughness due to embrittlement of tissue caused by excessive increase of apatite density. This study focused on the change of impact fracture characteristics of cortical bone tissue with reduction of apatite concentration (demineralization). A compact-sized impact loading device for Charpy tests was developed to measure the absorbed energy for impact fracture of bone specimens in the 0.5 and 1.0 J input energy range. Cortical bone specimens of 3 × 3 × 30 mm were prepared from shaft of bovine femurs. Differences relating to the anisotropy in axial and circumferential direction of the femur were observed in the absorbed energy values. The values of the axial specimens were greater than the circumferential specimens. Axial bone specimens were demineralized in ethylenediaminetetraacetic acid (EDTA) solution at 5°C. The demineralization progressed slowly from surfaces of the specimen. The 24-hour demineralization created a collagen layer at the surface of specimen and the demineralized specimen showed higher absorbed energy than unprocessed specimens. The absorbed energy in defective specimens with a square shaped small slit of 0.5 × 0.5 mm increased after local demineralization process. The time for effective demineralization could be reduced to 2 hours in the case of 37°C condition. The demineralization process improved the fracture characteristics of both intact and defective cortical bone tissue. Key words : Bone tissue, Fracture, Charpy impact test, Apatite, Demineralization 1. Introduction The likelihood of living a long life of more than one hundred years has been increased by the great innovations of medical technology in recent years. However, maintaining the ability to walk by own legs over the long lifetime has never been ensured. The risk of bone fracture increases steadily with age due to brittleness of bone structures as typified by osteoporosis. Many kinds of tissues may be regenerated and replaced by stem cells or artificial organs in the near future. Improvement of bone structure also may be performed in the tissue engineering. However the application of tissue engineering for repair and reconstruction of the bone tissue remains to be a challenge. Although bone remodeling usually occurs in our internal structure, the cycle requires a long period of several months. Bone regeneration also depends on the time scale of the cycle. Living bone tissue has a structural adaptation function responding to external loads (Currey, 2003). If people stay in bed for the long time waiting for the regeneration process after bone fracture, it induces bone weakening caused by lack of stress stimulation. Thus the improvement of bone tissue should be performed in a rapid process. Mechanical properties of bone tissue are strongly affected by hierarchal structure formed by oriented materials and their combination on various scales (Fratzl and Weinkamer, 2007). This study focused on the structural interaction of microscopic components of bone tissue to discuss how to improve the fracture characteristics. 1 Received: 30 April 2016; Revised: 1 December 2016; Accepted: 13 February 2017

Bulletin of the JSME Journal of Biomechanical Science and

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Bulletin of the JSME Journal of Biomechanical Science and

Bulletin of the JSME

Journal of Biomechanical Science and EngineeringVol.12, No.3, 2017

© 2017 The Japan Society of Mechanical EngineersJ-STAGE Advance Publication date: 21 February, 2017Paper No.16-00267

[DOI: 10.1299/jbse.16-00267]

Demineralization of cortical bone for improvement of Charpy

impact fracture characteristics

Kazuhiro FUJISAKI*, Ayumi HASEGAWA*, Hiroya YOKOYAMA* and Kazuhiko SASAGAWA* * Department of Intelligent Machines and System Engineering, Hirosaki University

3, Bunkyo-cho, Hirosaki, Aomori, 0368561, Japan

E-mail: [email protected]

Abstract

Bone tissue is a composite structure of apatite particles distributed in collagen fibril matrix on a nano-size

scale. Mechanical properties of cortical bone are determined by the apatite-collagen composition. The amount

and specific orientation of apatite crystals strongly affect the mechanical properties of macroscopic bone tissue

such as anisotropic elastic modulus and fracture toughness. The progression of mineralization with tissue aging

results in a reduction of fracture toughness due to embrittlement of tissue caused by excessive increase of

apatite density. This study focused on the change of impact fracture characteristics of cortical bone tissue with

reduction of apatite concentration (demineralization). A compact-sized impact loading device for Charpy tests

was developed to measure the absorbed energy for impact fracture of bone specimens in the 0.5 and 1.0 J input

energy range. Cortical bone specimens of 3 × 3 × 30 mm were prepared from shaft of bovine femurs.

Differences relating to the anisotropy in axial and circumferential direction of the femur were observed in the

absorbed energy values. The values of the axial specimens were greater than the circumferential specimens.

Axial bone specimens were demineralized in ethylenediaminetetraacetic acid (EDTA) solution at 5°C. The

demineralization progressed slowly from surfaces of the specimen. The 24-hour demineralization created a

collagen layer at the surface of specimen and the demineralized specimen showed higher absorbed energy than

unprocessed specimens. The absorbed energy in defective specimens with a square shaped small slit of 0.5 ×

0.5 mm increased after local demineralization process. The time for effective demineralization could be

reduced to 2 hours in the case of 37°C condition. The demineralization process improved the fracture

characteristics of both intact and defective cortical bone tissue.

Key words : Bone tissue, Fracture, Charpy impact test, Apatite, Demineralization

1. Introduction

The likelihood of living a long life of more than one hundred years has been increased by the great innovations of

medical technology in recent years. However, maintaining the ability to walk by own legs over the long lifetime has

never been ensured. The risk of bone fracture increases steadily with age due to brittleness of bone structures as

typified by osteoporosis. Many kinds of tissues may be regenerated and replaced by stem cells or artificial organs in the

near future. Improvement of bone structure also may be performed in the tissue engineering. However the application

of tissue engineering for repair and reconstruction of the bone tissue remains to be a challenge. Although bone

remodeling usually occurs in our internal structure, the cycle requires a long period of several months. Bone

regeneration also depends on the time scale of the cycle. Living bone tissue has a structural adaptation function

responding to external loads (Currey, 2003). If people stay in bed for the long time waiting for the regeneration process

after bone fracture, it induces bone weakening caused by lack of stress stimulation. Thus the improvement of bone

tissue should be performed in a rapid process. Mechanical properties of bone tissue are strongly affected by hierarchal

structure formed by oriented materials and their combination on various scales (Fratzl and Weinkamer, 2007). This

study focused on the structural interaction of microscopic components of bone tissue to discuss how to improve the

fracture characteristics.

1

Received: 30 April 2016; Revised: 1 December 2016; Accepted: 13 February 2017

Page 2: Bulletin of the JSME Journal of Biomechanical Science and

2© 2017 The Japan Society of Mechanical Engineers

Fujisaki, Hasegawa, Yokoyama and Sasagawa, Journal of Biomechanical Science and Engineering, Vol.12, No.3 (2017)

[DOI: 10.1299/jbse.16-00267]

Bone tissue is a composite material consisting of hydroxyapatite-like mineral particles and proteins principally

involved in type I collagen production on a nano-size scale. The mineral, protein, and water content of bone is 65, 25,

and 10 wt.%, respectively (Olszta et al., 2007). The mechanical properties of bone tissue were well investigated and

focused on the characteristics of the mineral-collagen scale. The crystal structure of apatite is inhomogeneous (Raquel,

1981, Matsushima et al., 1986) and particle sizes are varied in bone regeneration processes, (Liu et al., 2010). The

microscopic structure of the apatite and collagen network is an indicator of bone quality, affecting the mechanical

properties of aged bone. The crystal orientation of apatite in bone tissue was used to evaluate the bone quality (Nakano

et al., 2002, 2012). The alignment of apatite crystals determines the anisotropy of bone tissue (Sasaki et al., 1989,

Sasaki and Sudoh, 1997, Giri et al., 2009), and the highest elastic modulus is observed along the axial direction in the

shaft of long bones (Yamamoto et al., 2012). The strain behavior of apatite crystals in bone tissue has been investigated

using X-ray diffraction (Gupta et al., 2006, Fujisaki et al., 2006, Almer et al., 2007, Giri et al., 2012). It was confirmed

that the hardness of apatite components and strain sharing ratio of apatite phases determine the elastic modulus of

macroscopic bone tissue (Fujisaki and Tadano, 2007). The change in apatite density in cortical bone strongly affects the

rigidity because the elastic modulus of apatite is more than one hundred times greater than that of the collagen matrix

(Zamiri and De, 2011). The reduction of elastic modulus of cortical bone in demineralization processes was confirmed

in stress-strain measurements of static tensile loading (Todoh et al., 2009). However, demineralized collagen fibers give

high bendability of the structure. An appropriate balance between collagen and apatite content is essential for

maintaining the desired material properties. Hence, excessive mineralization due to tissue aging increases brittleness

and reduces toughness of the tissue (Currey et al., 1996, Currey, 2004, Roschger et al., 2008). In this study,

demineralization is used as a chemical treatment of bone tissue in order to change the impact fracture characteristics. A

compact-sized impact loading device for Charpy-type tests is developed to evaluate the impact fracture characteristics

of cortical bone specimens. The effect of apatite eliminations on the impact behavior is investigated in the fracture tests

and observations of demineralized tissue. In addition, bone structural damage causes a stress concentration and brittle

fracture of the structure. We propose a method for improving the impact fracture characteristics of bone tissue with the

structural defect by means of local demineralization processes.

2. Materials and Methods

2.1 Charpy impact tests

A Charpy-type impact loading device was designed taking into considerations of the range of absorption energy

during fracture of cortical bone specimens. An impact load was applied under three-point bending condition with two

support points at a distance of 24 mm; 12 mm on either side of the impact point. The input load was applied at the

center of the longitudinal axis of the bone specimens. Figure 1 shows the impact loading device developed here. The

input energy of the impact tests was set to either 1.0 or 0.5 J by changing the arm part of the impact hammer. The

specifications of the testing device are listed in Table 1. The impact rates of both conditions were designed to be around

3 m/s. The absorption energy was measured as the reduction of potential energy during the hammer swing before and

after specimen destruction. The impact fracture toughness of bone tissue relates to the value of absorption energy. The

angle change of the hammer swing was tracked by observing the rotation indicator by means of high-speed camera with

200 fps. The absorbed energy, WC, was calculated by using Eq. (1),

𝑊𝐶 = 𝑀𝐻(cos 𝛼𝑅 − cos𝛼0) −𝑊𝑓 (1)

Where, MH is the hammer moment determined by hammer weight and distance from the center of rotation to the

weighted center of the hammer arm. The angles α0 and αR are measured at the initial and the end positions of the

hammer swing, respectively. The friction loss Wf was measured without specimen destruction, and the loss was below

1° in the swing system.

2

Page 3: Bulletin of the JSME Journal of Biomechanical Science and

2© 2017 The Japan Society of Mechanical Engineers

Fujisaki, Hasegawa, Yokoyama and Sasagawa, Journal of Biomechanical Science and Engineering, Vol.12, No.3 (2017)

[DOI: 10.1299/jbse.16-00267]

2.2 Sample preparation

Cortical bone samples were prepared from bovine femurs extracted from mature cows of 22 month old (sample 1)

and 28 month old (sample 2). Column-shaped specimens 3 × 3 × 30 mm in size were formed using a low speed wheel

saw (Model 650, South Bay Technology Inc.) under wet conditions with physiological saline applied to prevent sample

desiccation and heat generation. Impact loading tests were conducted under the three point bending condition. The long

axes of the specimens were selected along with each direction corresponding to the bone axial (specimen A) and

circumferential (specimen C) direction, as shown in Fig. 2. There were obvious differences in mechanical properties

between samples A and C because the cortical bone at mid-shaft of long bone shows strong anisotropy (Fujisaki et al.,

2006). The difference of these two specimens can be mainly used to confirm the performance of the impact testing

device. The acrylic specimens in same size were also prepared for reference materials without individual differences.

The specimen A was used to investigate the fracture characteristics considering with bending situations of long bones

and the effect of chemical treatments for demineralization on the bending fracture characteristics. Defective specimens

were created using an additional removal machining process. A small size 0.5 × 0.5 mm square-shaped slit, as shown in

Fig. 2, was created using the low speed wheel saw at the center of the surface experiencing tensile strain under the

three-point bending, which was on the opposite side of the impact point as shown in Fig. 1.

Fig. 2 Cortical bone specimens cut out from a bovine femur. A square shaped small slit was added to the surface of

specimen A. Tensile stress applied to the defect area in three point bending condition in Charpy impact test.

Fig. 1 A compact-sized Charpy-type loading device. The input energy can be selected at 0.5 or 1.0 J by changing the

hammer arm. This picture shows the device having 0.5 J arm.

Input energy [J] 0.5 1.0

Hammer weight [kg] 0.512 0.752

Distance of weight center [mm] 82.9 98.0

Hammer moment [Nm] 0.416 0.723

Initial angle [deg] 103 112

Impact rate [m/s] 3.03 2.94

Table 1 Specification of Charpy loading device set for 0.5 and 1.0J input energy.

3

Page 4: Bulletin of the JSME Journal of Biomechanical Science and

2© 2017 The Japan Society of Mechanical Engineers

Fujisaki, Hasegawa, Yokoyama and Sasagawa, Journal of Biomechanical Science and Engineering, Vol.12, No.3 (2017)

[DOI: 10.1299/jbse.16-00267]

2.3 Chemical treatment

Bone demineralization was performed in 10% (w/v) ethylenediaminetetraacetic acid (EDTA) - water solution in a

300 ml vessel. Two types of demineralization conditions were used in this experiment. In the first condition, bone

specimens were dipped in EDTA solution at 5°C under agitating with a magnetic stirrer for the duration of treatment.

The chemical reaction progressed gradually for several days. The second condition utilized the EDTA solution at a

physiological temperature of 37°C which was expected to reduce the treatment time and to confirm the clinical

relevancies. The EDTA was saturated in both conditions. In the case of defective bone study, the specimens were

masked to limit the treatment area near the slit and then placed in the EDTA solution with agitating. The mechanical

properties of intact, defected and local demineralized bone specimens were measured in both the static and the impact

loading tests.

3. Results

3.1 Evaluation of impact testing

Charpy impact loading tests were conducted for specimens A and C without notch cut out from sample 1. The

fractures occurred at the center of the specimen during the three-point bending in the impact test. The direction of crack

propagation on the fractured surface was irregular in the specimen A and straight in the specimen C. Figure 3 shows the

absorbed energy measured in each specimen under the 1.0 J input energy condition in Charpy impact loading test. The

values (mean ± S.D. (n=5)) were 55.3 ± 3.0 mJ in the axial (specimen A), 20.0 ± 3.0 mJ in the circumferential

(specimen C) specimens, and 61.2 ± 2.8 mJ in the referenced acrylic specimens. The specimen A had significantly

larger absorption energy than the specimen C. The repeatable accuracy of the experiment using this device can be

evaluated from the value of standard deviation of acrylic results which is thought to have little individual difference.

Although the bone specimens usually have individual differences even if the specimens are taken from same bovine

femur, the standard deviation values of the both bone specimens were almost same comparing with the acrylic result in

this experiment.

3.2 Demineralization process

The bone axial specimens (specimen A) were chemically treated. Demineralization gradually progressed from the

surface of the specimen in the 5°C temperature condition. The cross-sectional images of the 24 h treated are shown in

Fig. 4(a). The demineralization layer was created at the surface of specimen. The thickness of the obvious

demineralized area which was recognized in the optical image was 90 μm after 24 h, and then up to 180 μm after 48 h

Fig. 3 Anisotropic fracture characteristics of cortical bone obtained from axial (specimen A) and circumferential

(specimen C) directions cut out from bovine femur (sample 1). An acrylic specimen was used as a reference.

The absorbed energy values (mean ± S.D. (n=5)) were measured in the impact loading tests.

4

Page 5: Bulletin of the JSME Journal of Biomechanical Science and

2© 2017 The Japan Society of Mechanical Engineers

Fujisaki, Hasegawa, Yokoyama and Sasagawa, Journal of Biomechanical Science and Engineering, Vol.12, No.3 (2017)

[DOI: 10.1299/jbse.16-00267]

in the EDTA solution. The demineralization rate slowed after 48 h. The complete demineralization required a longer

period of more than two weeks in the 5°C temperature condition. The same demineralization thickness of around 90 μm

could be obtained within 2 h in the 37°C temperature condition, as shown in Fig. 4(b). The demineralization was also

progressed from the surface of the specimen in these conditions. The treatment area could be limited by using vinyl

tape masks. An unmasked area was located at the center of specimen with 4 mm width (BS) which was demineralized

at the both sides of tensile and compressive deformation in bending. And an unmasked area with 2 mm only on the

tensile side at the center of specimen (TS) was used for performing the locally focused demineralization.

3.3 Absorbed energy in demineralized specimen

Figure 5 shows the absorbed energy of specimen A in sample 1 without defect (Sample 1_intact) prepared under

different demineralization treatment times of 12, 24, 48 and 72 h in the 5°C temperature condition. The experiments

were conducted under an input energy of 1.0 J. The absorbed energy increased after 24 h demineralization. Although

the prolonged treatments of more than 48 h reduced the absorbed energy, indestructible areas were observed at the

demineralized layer on the compressive surface of specimens. The specimen that was demineralized for more than one

month had high bendability with low elastic resistances and could not break under the impact loading condition.

The experiments for defective specimens were conducted under 0.5 J input energy. The masks with 4 mm

unmasked at the center of specimens were used to limit the treatment area. The addition of a slit-shaped defect

significantly reduces the impact fracture strength because of both the stress concentration around structural defect and

the reduction of cross sectional area at the impact point. The time-dependent effects of demineralization at 5°C on the

absorbed energy measured in both samples are shown in Fig. 5. And there were individual differences between the

specimens taken from sample 1 and sample 2. The absorbed energy values increased even after 72 h treatment

compared with untreated state in both sample.

Figure 6 shows the absorbed energy of demineralized specimens (sample 2) with the structural defect and treated at

37°C for 2 h. Two types of masks were used here, expressed in Fig. 6, one with a 4 mm exposed area including both the

tensile and compression sides of specimens (BS) and another one with a 2 mm exposed area on the tensile (defected)

side only (TS). The values (mean ± S.D. (n=5)) were 8.4 ± 4.0 mJ in initial condition (W/O), 25.5 ± 6.4 mJ in BS, and

21.2 ± 5.0 mJ in TS specimens. The significant differences (P<0.01) in two-sample unequal variance t-test between

W/O and BS, W/O and TS were obtained with P-values (one-sided) of 0.0007, 0.001, respectively. There were obvious

increases in the absorbed energy values after demineralization under both the BS and TS conditions. The results

showed that the demineralization improved the impact fracture resistance even if the treatment was limited to the local

area in the immediate vicinity of small defect (TS).

The load-deflection curve with 0.1 mm/min loading rate of typical bone specimens were shown in Fig. 7. These

static loading behaviors were obtained from the specimen without defect (intact_0h) and the defected specimens before

treatment (defect_0h) and after treatment (TS_2h). Both the maximum load and the maximum deflection obviously

decreased by creating the small slit. The fracture behaviors were brittleness in the case of before treatment. Although

the elastic modulus decreased in the demineralized specimen case, static bendability was higher than the before

treatment.

Fig. 4 Microscopic images of the cross-sectional area of an intact cortical bone specimen after 24 h

demineralization in EDTA solution at 5°C (a), a defective specimen after 2 h demineralization at 37°C (b).

5

Page 6: Bulletin of the JSME Journal of Biomechanical Science and

2© 2017 The Japan Society of Mechanical Engineers

Fujisaki, Hasegawa, Yokoyama and Sasagawa, Journal of Biomechanical Science and Engineering, Vol.12, No.3 (2017)

[DOI: 10.1299/jbse.16-00267]

Figure 8 shows the scanning electron microscope (SEM) images of fracture surfaces of impact loading and static

loading specimens with and without demineralization treatment in the TS condition. The demineralize tissue effects

were confirmed at the edge of defected area, as shown in (b) and (d). The fracture surfaces showed distinguishing

pattern in each situation. The fracture surfaces in impact fracture cases were smoother than in static cases. The osteon

patterns with Haversian canals were recognized in the demineralization case under impact loading (b).

Fig. 5 The absorbed energy of specimens prepared in different demineralization treatment times. “Sample1_intact” means

specimen A taken from sample 1 without defect measured at 1.0 J input energy. “Sample1_defect” and

“Sample2_defect” mean specimen A with a defect taken from sample 1 and 2, respectively, measured at 0.5 J input

energy.

Fig. 7 Static bending behavior of typical specimens (Sample 2, specimen A) of intact and defected with and without

demineralization treatment. The load-deflection curves were measured in three points bending as the same

geometry of the impact loading test.

Fig. 6 Absorbed energy (mean ± S.D. (n=5)) of defective specimens (Sample 2, specimen A) after 2 h of

demineralization under 37°C with different masking conditions. “BS” is 4 mm of unmasked width on both the

compressive and tensile strain sides of the specimen, “TS” is 2 mm unmasked width on the tensile loading side of

the specimen.

6

Page 7: Bulletin of the JSME Journal of Biomechanical Science and

2© 2017 The Japan Society of Mechanical Engineers

Fujisaki, Hasegawa, Yokoyama and Sasagawa, Journal of Biomechanical Science and Engineering, Vol.12, No.3 (2017)

[DOI: 10.1299/jbse.16-00267]

4. Discussion

Impact fracture characteristics of cortical bone specimens with a slit shaped defect were explored in this study. We

used a compact sized Charpy type loading device which can work with the small impact energy of 0.5 J, and the

differences of absorption energy of each specimen were measured. Both the defected specimens based on specimen A

and the intact specimen C absorbed the energy only less than 25 mJ during the impact fractures, expressed in Fig. 3 and

6. Reliability of the value could be confirmed by considering with the static fracture absorption energy calculated from

the areas of load-deflection curves for specimen A with defect. However this input energy level is too small to discuss

the detail process of deformation behavior at the impact moment. A more accurate impact test with small input energy

is required for analyzing the function of demineralized collagen layer. The fracture surfaces inclined with the

perpendicular direction of bending axis. And non-smooth fracture surfaces were obtained in bone axial specimens

because of bone axial oriented osteon structures. Osteon structures of bovine femoral bone often show plexiform

patterns. There is a possibility that the crack propagation into the bone tissue is to be complex behaviors compared with

human bone constructed with circular osteon structures. The cross sectional areas directly correspond to the absorption

energy especially in bone axial and circumferential without slit cases.

Fracture toughness of bone is greatly affected by water content, amount of tissue, porosity, osteon generation, and

mineral content (Aerssens et al., 1998). The mineral content of bone can be manipulated by using chemical treatments.

The demineralization by means of chemical treatment usually progresses from the outer surface of the bone, which was

observed in this study. The surface strain has the maximum value during bending of the cortical shell. The stress

reduction based on elimination of stress-strain concentrations was resulted in the demineralization process. Although

the obvious demineralized area was less than 100 μm in the suitable condition here, the absorption energy increased in

both intact and defective specimens. The fracture surface of demineralized specimen was extensively different from the

fracture surface of untreated specimen. The osteon patterns with Haversian canals were observed in the SEM image of

fracture surface of the demineralized specimen as shown in Fig. 8. Thus demineralization effects from the surface

might be progressed mainly though the boundary of osteons. The fracture surfaces are also depending on the strain rate

in bending for bone axial specimen (Zimmermann et al., 2014). Fracture surface observations are important for

evaluation of the effectiveness of demineralization treatments in our future works.

The demineralization process is often used to observe the anisotropic structure of collagen matrix in bone tissue

(Novitskaya et al., 2011). For example, microscopic observation of the apatite structure and the collagen orientations in

bone tissue can be conducted in deproteinization and demineralization treatments, respectively. As expected, the

mechanical properties can be strategically changed as a result of these usual treatment processes. We insist that the

widely used demineralization technique is available not only to analyze the bone structure but also to improve the

impact fracture characteristics of bone. The bending load usually acts to the specific part such as femoral neck, mid part

of long bone and the stress concentration often causes bone fracture. Thus, the locally-controlled demineralization of

micro-scale area is expected to reduce the risk of bone fracture without reduction of macroscopic rigidity of the area. In

Fig. 8 SEM images of fracture surfaces of impact loading specimens (a) without treatment and (b) with 2 h treatment in

tensile side(TS), and static loading specimens (c) without treatment and (d) with 2 h treatment in TS.

7

Page 8: Bulletin of the JSME Journal of Biomechanical Science and

2© 2017 The Japan Society of Mechanical Engineers

Fujisaki, Hasegawa, Yokoyama and Sasagawa, Journal of Biomechanical Science and Engineering, Vol.12, No.3 (2017)

[DOI: 10.1299/jbse.16-00267]

this study, the demineralization process was controlled by EDTA solution. The EDTA treatment is used for chemical

treatment of extracted human bone tissue. If we use this like demineralization technique for reducing the risk of living

bone, it is required to investigate the damage of surrounded living tissue and haw to supply and restrict the diffusion of

solution in vivo situations.

This study focused on only the apatite phase of bone tissue by decreasing apatite content via demineralization in

order to improve the fracture characteristics. Aged bone has not only excessive mineralization tissue but also damaged

collagen fibers (Manilay et al., 2013). The crosslinking of collagen fibrils is also a cause of bone brittleness.

Adjustments to both the apatite composition and collagen flexibility are required for repairing the aged bone tissue.

5. Conclusion

The impact fracture characteristics of bovine cortical bone specimens were evaluated using Charpy-type impact

loading tests. The anisotropic fracture characteristics measured as differences of absorbed energy values were clearly

obtained in this system. These values were higher in the axial bone specimens than in the circumferential specimens.

The demineralization using EDTA solution progressed from the surface of bone specimen and demineralized layer was

created in this process. The absorbed energy in the impact fracture tests for both the intact and the defective bone

specimens increased in the specific demineralization condition. The demineralization in the immediate vicinity of the

defective area was enough to improve the impact fracture characteristics of cortical bone tissue.

Acknowledgment

This work was partly supported by JSPS KAKENHI Grant-in-Aid for Scientific Research: No. 24500503 and

No.15H02207.

References

Aerssens, J., Boonen, S., Lowet, G. and Dequeker, J., Interspecies differences in bone composition, density, and

quality: potential implications for in vivo bone research, Endocrinology, Vol.139, No.2, (1998), pp. 663–670.

Almer, J.D. and Stock, S.R., Micromechanical response of mineral and collagen phases in bone, Journal of Structual

Biology, Vol.157, No.2 (2007), pp. 365–370.

Currey, J.D., Brear, K. and Zioupos, P., The effects of aging and changes in mineral content in degrading the toughness

of human femora, Journal of Biomechanics, Vol.29, No.2 (1996), pp. 257 260.

Currey. J.D., The many adaptations of bone, Journal of Biomechanics, Vol.36, No.10 (2003), pp. 1487–1495.

Currey, J.D., Tensile yield in compact bone is determined by strain, post-yield behavior by mineral content, Journal of

Biomechanics, Vol.37, No.4 (2004), pp. 549–556.

Fratzl, P. and Weinkamer, R., Nature’s hierarchical materials, Progress in Materials Science, Vol.52, No.8 (2007), pp.

1263–1334.

Fujisaki, K., Tadano, S. and Sasaki, N., A method on strain measurement of HAP in cortical bone from diffusive profile

of X-ray diffraction, Journal of Biomechanics, Vol.39, No.3 (2006), pp. 579–586.

Fujisaki, K. and Tadano, S., Relationship between bone tissue strain and lattice strain of HAp crystals in bovine cortical

bone under tensile loading, Journal of Biomechanics, Vol.40, No.8 (2007), pp. 1832–1838.

Giri, B., Tadano, S., Fujisaki, K. and Sasaki, N., Deformation of mineral crystals in cortical bone depending on

structural anisotropy, Bone, Vol.44, No.6 (2009), pp. 1111–1120.

Giri, B., Almer, J.D., Dong, X.N. and Wang, X., In situ mechanical behavior of mineral crystals in human cortical bone

under compressive load using synchrotron X-ray scattering techniques, Journal of Mechanical Behavior of

Biomedical Materials, Vol.14, (2012), pp. 101–112.

Gupta, H.S., Seto, J., Wagermaier, W., Zaslansky, P., Boesecke, P. and Fratzl, P., Cooperative deformation of mineral

and collagen in bone at the nanoscale, Proceedings of the National Academy of Sciences of the United States of

America, Vol.103, No.47 (2006), pp. 17741–17746.

Liu, X. S, Cohen, A., Shane, E., Yin, P.T., Stein, E. M., Rogers, H., Kokolus, S.L., McMahon, D.J., Lappe, J.M.,

Recker, R.R., Lang, T. and Guo, X.E., Bone density, geometry, microstructure, and stiffness: Relationships

8

Page 9: Bulletin of the JSME Journal of Biomechanical Science and

2© 2017 The Japan Society of Mechanical Engineers

Fujisaki, Hasegawa, Yokoyama and Sasagawa, Journal of Biomechanical Science and Engineering, Vol.12, No.3 (2017)

[DOI: 10.1299/jbse.16-00267]

between peripheral and central skeletal sites assessed by DXA, HR-pQCT, and cQCT in premenopausal women,

Journal of Bone Mineral Research, Vol.25, No.10 (2010), pp. 2229–2238.

Manilay, Z., Novitskaya, E., Sadovnikov, E. and McKittrick, J., A comparative study of young and mature bovine

cortical bone, Acta Biomaterialia, Vol.9, No.2 (2013), pp. 5280–5288.

Matsushima, N., Tokita, M. and Hikichi, K., X-ray determination of the crystallinity in bone tissue, Biochimica et

Biophysica Acta, Vol.883, No.3 (1986), pp. 574–579.

Nakano, T., Kaibara, K., Tabata, Y., Nagata, N., Enomoto, S., Marukawa, E. and Umakoshi, Y., Unique alignment and

texture of biological apatite crystallites in typical calcified tissues analyzed by microbeam X-ray diffractometer

system, Bone, Vol.31, No.4 (2002), pp. 479–487.

Nakano, T., Kaibara, K., Ishimoto, T., Tabata, Y. and Umakoshi, Y., Biological apatite (BAp) crystallographic

orientation and texture as a new index for assessing the microstructure and function of bone regenerated by tissue

engineering, Bone, Vol.51, No.4 (2012), pp. 741–747.

Novitskaya, E., Chen, P.-Y., Lee, S., Castra-Cesena, A., Hirata, G., Lubarda, V.A. and McKittrick, J., Anisotropy in the

compressive mechanical properties of bovine cortical bone and the mineral and protein constituents, Acta

Biomaterialia, Vol.7, No.8 (2011), pp. 3170–3177.

Olszta, M.J., Cheng, X.G., Jee, S.S., Kumar, R., Kim, Y.Y., Kaufman, M.J., Douglas, E.P. and Gower, L.B., Bone

structure and formation: A new perspective, Materials Science and Engineering R, Vol.58, No.3-5 (2007), pp. 77–

116.

Raquel, Z.L., Apatites in biological systems, Progress in Crystal Growth and Characterization of Materials, Vol.4,

(1981), pp. 1–45.

Roschger, P., Paschalis, E.P., Fratzl, P. and Klaushofer, K., Bone mineralization density distribution in health and

disease, Bone, Vo.42, No.3 (2008), pp. 456–466.

Sasaki, N., Matushima, N., Ikawa, T., Yamamura, H. and Fukuda, A., Orientation of bone mineral and its role in the

anisotropic mechanical properties of bone – transverse anisotropy, Journal of Biomechanics, Vol.22, No.2 (1989),

pp. 157–164.

Sasaki, N. and Sudoh, Y., X-ray pole Fig. analysis of apatite crystals and collagen molecules in bone, Calcified Tissue

International, Vol.60, No.4 (1997), pp. 361–367.

Todoh, M., Tadano, S., Giri, B., Nishimoto and M., Effect of gradual demineralization on the mineral fraction and

mechanical properties of cortical bone, Journal of Biomechanical Science and Engineering, Vol.4, No.2 (2009),

pp. 230–238.

Yamamoto, K., Nakatsuji, T., Yaoi, Y., Yamato, Y., Yanagitani, T., Matsukawa, M., Yamazaki, K. and Matsuyama, Y.,

Relationships between the anisotropy of longitudinal wave velocity and hydroxyapatite crystallite orientation in

bovine cortical bone, Ultrasonics, Vol.52, No.3 (2012), pp. 377–386.

Zamiri, A. and De, S., Mechanical properties of hydroxyapatite single crystals from nanoindentation data, Journal of

Mechanical Behavior of Biomedical Materials, Vol.4, No.2 (2011), pp. 146–152.

Zimmermann, E.A., Gludovatz, B., Schaible, E., Busse B. and Ritchie, R.O., Fracture resistance of human cortical bone

across multiple length-scales at physiological strain rates, Biomaterials, Vol.35, No.21 (2014), pp. 5472–5481.