8
Bulkscan LMS511 Flow sensor PRODUCTINFORMATION

Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

Bulkscan LMS511

Flow sensor

PR

OD

Uc

TIN

FO

RM

ATI

ON

Page 2: Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

ABCDEF

HIJKLMNOPQRST F L U I D S e N S O R S | S I c K 8015028/2012-05-08

Subject to change without notice

Flow sensors

2

Bulkscan LMS511

Product descriptionThe Bulkscan LMS511 uses time-of-flight technology for non-contact measurement of volume flow on conveyor belts. Using the multi-echo technology, the Bulkscan can combine time-of-flight data with the belt speed to generate a reliable volume flow signal, regardless of the bulk mate-rial's properties or weather conditions. Aside from calculating total quantities and mass flow, the Bulkscan can moni-tor the operation of the conveyor belt without coming into physical contact with

it and promptly gives warning of any belt slippage. The integrated center-of-gravity calculator can be used to detect uneven loading of the bulk material and avoid excessive belt wear. Its tough industrial housing is well suited to rugged operat-ing conditions. An integrated heater also ensures safe operation at low ambient temperatures. Discrete signals as well as Ethernet TCP/IP can be used to connect the measuring system to a host commu-nication system.

At a glance • Non-contact measurment of volume

and mass flow of bulk material • Laser pulses with high angular

resolution ensure outstanding image resolution

• 5-echo pulse evaluation produces highly reliable measurements

• Offers non-contact belt monitoring

• Integrated center-of-gravity calculator • Robust structure for harsh ambient

conditions • Can also measure at low tempera-

tures thanks to integrated heater • Compact housing with enclosure rat-

ing IP67

Your benefits • Maximizes conveyor throughput • Reduces maintenance costs by pre-

venting belt slippage • Increases the conveyor belt’s service

life • Reduces loading time

• Increases efficiency by optimizing belt capacity

• Simple installation • Low maintenance costs • Offers savings through minimized

energy consumption

Non-contact and maintenance-free sensor for measuring volume flow

Multi-echotechnologyMulti-echotechnology

Additional informationDetailed technical data. . . . . . . . . . . . .3

Ordering information. . . . . . . . . . . . . . .4

Dimensional drawings . . . . . . . . . . . . .4

Accessories . . . . . . . . . . . . . . . . . . . . . .6 - www.mysick.com/en/Bulkscan_LMS511

For more information, just enter the link and get direct access to technical data, CAD design models, operating instruc-tions, software, application examples and much more.

Page 3: Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

ABCDEF

HIJKLMNOPQRSTF L U I D S e N S O R S | S I c K8015028/2012-05-08

Subject to change without notice

Flow sensors

3

Bulkscan LMS511

Detailed technical data

Features

Light source Infrared (905 nm)

Laser class 1, eye-safe (IEC 60825-1 (2007-6))

Field of view 190°

Scanning frequency 35 Hz, 50 Hz, 75 Hz

Heating Yes

Operating range 0.5 m ... 10 m

Amount of evaluated echoes 5

Performance

Response time 13 ms, 20 ms, 28 ms

Average filter 0 s ... 3,600 s

Accuracy ± 3 %, under perfect conditions≤ ± 5 %, depending on the profile

Max. conveyor speed ≤ 30 m/s

Interfaces

Auxiliary interface

Protocol USB 2.0

Data transmission rate ≤ 500 kBaud

Serial host interfaces

Protocol RS-232/RS-422

Data transmission rate ≤ 500 kBaud

ethernet

Protocol TCP/IP

Data transmission rate 100 Mbit/s

cAN

Protocol CANopen, CSN (SICK CAN sensor network)

Data transmission rate ≤ 1,000 kbit/s

Switching inputs 2, 2 Encoder

Switching outputs 6

Optical indicators 5 LEDs (additional 7-segment display)

Mechanics/electronics

electrical connection M12 5-pin plug-in connector

Supply voltage scanner/heater 19.2 V ... 28.8 V

Prohibited residual ripple ± 5 %

Switch-on peak current 2 A

Operating current scanner 1,3 A

Power consumption 22 W, + 55 W heating (typical)

Housing color Gray (RAL 7032)

enclosure rating IP 67 (EN 60529, Section 14.2.7)

Protection class III

Page 4: Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

ABCDEF

HIJKLMNOPQRST F L U I D S e N S O R S | S I c K 8015028/2012-05-08

Subject to change without notice

Flow sensors

4

Bulkscan LMS511

Weight 3.7 kg

Dimensions 160 mm x 155 mm x 185 mm

Distance of the sensor to the bulk solid ≥ 0.5 m

Switch-on time ≤ 60 s

Ambient data

electromagnetic compatibility (eMc) EN 61000-6-2:2005 / EN 61000-6-3 (2001-10)

Ambient operating temperature –30 °C ... +50 °C

Storage temperature –30 °C ... +70 °C

Ambient light safety 70,000 lx

Ordering informationModel name Part no.

Bulkscan LMS511-20190 1059529

Dimensional drawingsLMS511

159(6.26)

93(3.66)

55 (2.1

7)

21

120

(4.7

2)32 (1.2

6)

137(5.39)

147(5.79)

3155

(6.10)

11 (0.4

3)18

5(7

.28)

63 (2.4

8)

(3.05)77.5

91(3.58)

43 (1.6

9)

190°

1 4 screw holes M8 x 92 Do not obstruct front window3 4 screw holes M6 x 8

2

All dimensions in mm (inch)

Page 5: Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

ABCDEF

HIJKLMNOPQRSTF L U I D S e N S O R S | S I c K8015028/2012-05-08

Subject to change without notice

Flow sensors

5

Bulkscan LMS511

Mounting bracket

1 2

1 Mounting bracket2 Mounting set for LMS2xx Part no. 2018303

Pole mounting bracket

1

2

1 Pole mounting bracket2 Adapter bracket

Page 6: Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

ABCDEF

HIJKLMNOPQRST F L U I D S e N S O R S | S I c K 8015028/2012-05-08

Subject to change without notice

Flow sensors

6

Bulkscan LMS511

Mounting set 3

4 1 2 3

1 Mounting set 12 Mounting set 23 Mounting set 34 Product

Accessories

Measuring wheel encoder

Model name Part no.

Illustration may differ

DFV60A-22PK65536 1051331

Mounting brackets/plates

Brief description Model name Part no.

Mounting bracket for LMS5xx (for retrofitting, if 2018303 is already in use) Mounting bracket 2059271

Mounting bracket for direct mounting, from the rear, on wall or machine, not adjustable Mounting kit 1 2015623

Mounting bracket for rear mounting on wall or machine, adjustable longitudinal and lateral axes, only in conjunction with mounting kit 1 (2015623) Mounting kit 2 2015624

Mounting bracket for rear mounting on wall, floor, or machine, adjustable longitudinal and lateral axes, only in conjunction with mounting kit 1 (2015623) and 2 (2015624) Mounting kit 3 2015625

Power supply units/ power cord connectors

Terminal and alignment brackets

Brief description Model name Part no.

Pole bracket (additionally required: adapter bracket 2059271 for LMS5xx / mounting set 2018303 for LD-LRS) Alignment bracket 2018304

Page 7: Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

ABCDEF

HIJKLMNOPQRSTF L U I D S e N S O R S | S I c K8015028/2012-05-08

Subject to change without notice

Flow sensors

7

Bulkscan LMS511

Model name Part no.

Power supply DC 24 V / 4 A Power supply 6010362

Power supply DC 24 V / 10 A Power supply unit 6020875

Optics cloths

Brief description Model name Part no.

Lens cloth Lens cloth 4003353

Programming/Configuration ToolBrief description Model name Part no.

Scan finder, receiver to localize infra red scans LASER-SUCHER LS-70 6020756

Other mounting accessoriesBrief description Model name Part no.

Strap for mast bracket (sold by meter) Clamping strap 5306222

Strap lock Clamping strap lock 5306221

Plug connectors and cables

Brief description Model name Part no.

I/O connection cable, 12-pole, shielded, M12 plug, 12-pin (A-type encoded) / open end, 10 m

Connecting cable (plug-open) 6042733

I/O connection cable, 12-pole, shielded, M12 plug, 12-pin (A-type encoded) / open end, 5 m

Connecting cable (plug-open) 6042732

I/O connection cable, 12-pole, shielded, M12 plug, 12-pin (A-type encoded) / open end, 20 m

Connecting cable (plug-open) 6042734

Ethernet cable, 4-pole, shielded, M12 plug, 4-pin (D-type encoded) / RJ-45 plug, 8-pin, 5 m

Connecting cable (plug-plug) 6034415

Power supply cable, 4 x 0,75 mm², shielded, M12 socket, 5-pin (A-type encoded) / open end, 10 m

Connecting cable (socket-open) 6042565

Power supply cable, 4 x 0,75 mm², shielded, M12 socket, 5-pin (A-type encoded) / open end, 20 m

Connecting cable (socket-open) 6042564

Power supply cable, 4 x 0,50 mm², shielded, M12 socket, 5-pin (A-type encoded) / open end, 5 m

Connecting cable (socket-open) 6036159

Data (RS-232/-422) and I/O connection cable, 12-pole, shielded, M12 socket, 12-pin (A-type encoded) / open end, 5 m

Connecting cable (socket-open) 6042735

Data (RS-232/422) and I/O connection cable, 12-pole, shielded, M12 socket, 12-pin (A-type encoded) / open end, 10 m

Connecting cable (socket-open) 6042736

Data (RS-232/422) and I/O connection cable, 12-pole, shielded, M12 socket, 12-pin (A-type encoded) / open end, 20 m

Connecting cable (socket-open) 6042737

USB cable, 4-pole, shielded, plug type mini B / plug type A, 3 m Connection cable (plug-plug) 6042517

– SSL-2J04-G10ME 6030928

Ethernet cable, 4-pole, shielded, M12 plug, 4-pin (D-type encoded) / RJ-45 plug, 8-pin, 20 m SSL-2J04-G20ME 6036158

Page 8: Bulkscan LMS511 - Auser Oy · Prohibited residual ripple ± 5 % Switch-on peak current 2 A Operating current scanner 1,3 A Power consumption 22 W, + 55 W heating (typical) Housing

8015

028/

2012

-05-

08 ∙

SD (2

012-

05) ∙

WB

USm

od d

e37

SICK AG | Waldkirch | Germany | www.sick.com

Leading technologies

With a staff of more than 5,000 and over 50 subsidiaries and representa-tions worldwide, SICK is one of the leading and most successful manufac-turers of sensor technology. The power of innovation and solution competency have made SICK the global market leader. No matter what the project and industry may be, talking with an expert from SICK will provide you with an ideal basis for your plans – there is no need to settle for anything less than the best.

Unique product range

• Non-contact detecting, counting, classifying, positioning and measur-ing of any type of object or media

• Accident and operator protection with sensors, safety software and services

• Automatic identification with bar code and RFID readers

• Laser measurement technology for detecting the volume, position and contour of people and objects

• Complete system solutions for analy-sis and flow measurement of gases and liquids

Comprehensive services

• SICK LifeTime Services – for safety and productivity

• Application centers in Europe, Asia and North America for the develop-ment of system solutions under real-world conditions

• E-Business Partner Portal www.mysick.com – price and availabi-lity of products, requests for quotation and online orders

SIcK at a glance

Worldwide presence with subsidiaries in the following countries:

Australia Belgium/Luxembourg Brasil ceská Republika canada china Danmark Deutschland españa France Great Britain India Israel Italia Japan

México Nederland Norge Österreich Polska România Russia Schweiz Singapore Slovenija South Africa South Korea Suomi Sverige Taiwan Türkiye United Arab emirates USA

Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com