When it comes to protecting patients, staff and instruments, which system will you choose? The EVOTECH ® ECR is a highly automated endoscope reprocessor, which helps provide safety, consistency, and compliance. Built with Safety in Mind C O N S I S T E N C Y C O M P L I A N C E S A F E T Y 060134-180508

Built with Safety in Mind...When it comes to protecting patients, staff and instruments, which system will you choose? The EVOTECH® ECR is a highly automated endoscope reprocessor,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Built with Safety in Mind...When it comes to protecting patients, staff and instruments, which system will you choose? The EVOTECH® ECR is a highly automated endoscope reprocessor,

When it comes to protecting patients, staff and instruments, which system will you choose? The EVOTECH® ECR is a highly automated endoscope reprocessor, which helps provide safety, consistency, and compliance.

Built with Safety in Mind CON

SISTEN

CY

COMPLIANCE

SAF

ETY

060134-180508

Page 2: Built with Safety in Mind...When it comes to protecting patients, staff and instruments, which system will you choose? The EVOTECH® ECR is a highly automated endoscope reprocessor,

PATIENT SAFETY:• Each endoscope channel is connected to a separate pump for

proper perfusion based on endoscope make and model, allowing for automatic leak and blockage detection*

• Clamshell basin minimizes mated scope surfaces• CIDEZYME® XTRA Multi Enzymatic Detergent contains multiple

enzymes for rapid, effective removal of bioburden• Provides automated cleaning and high-level disinfection of

endoscopes*

STAFF SAFETY:• Integrated minimum effective concentration (MEC) reduces

healthcare worker exposure to chemicals• CIDEX® OPA Concentrate Solution requires no pouring and is odor-free

ENDOSCOPE SAFETY:• Helical tube shields protect delicate distal end from damage• Positive pressure mitigates against leaks*

• Multi-channel leak test at start and end of every cycle

* Automatic leak and block detection may not apply to all scopes or cycles. Please refer to the EVOTECH® ECR User’s Guide and specific connection diagrams for more detailed information regarding cycle capabilities.

060134-180508

SAFETY

Page 3: Built with Safety in Mind...When it comes to protecting patients, staff and instruments, which system will you choose? The EVOTECH® ECR is a highly automated endoscope reprocessor,

* Automatic leak and block detection may not apply to all scopes or cycles. Please refer to the EVOTECH® ECR User’s Guide and specific connection diagrams for more detailed information regarding cycle capabilities.

060134-180508

CONSISTENCY

SINGLE-SHOT CHEMISTRY, FRESH DISINFECTANT FOR EVERY SCOPE, EVERY TIME

INTEGRATED MEC, NO TEST STRIPS

REQUIRED

AUTOMATION MEANS CONFIDENCE FROM

START TO FINISH

INDIVIDUAL CHANNEL MONITORING*

FINISH

Fina

l Rin

se

Alcohol F

lush Leak Test Leak Test Pre-Rinse

Wash

Disinfect/MEC Monitoring

R

inse

XTRA

Multi Enzym

atic Detergent

Page 4: Built with Safety in Mind...When it comes to protecting patients, staff and instruments, which system will you choose? The EVOTECH® ECR is a highly automated endoscope reprocessor,

Have the confidence and peace of mind that reprocessing steps are completed and documented.

COMPLIANCE

The EVOTECH® ECR monitors critical cycle information, which is recorded and printed out for easy and accurate recordkeeping.

032473-150402

EVOTECH(tm) System S/N 5041100223Mon 12/06/11 12:38:43Ver. 7.A.1

SW Part No.: 04−52230−7−001 Rev.AResource SW No. :100117−15A.1

State Medical CenterEndoscopy1

Basin : ADaily A Cycle#: 8Total A Cycle#: 55Total Cycle# : 105Manufacturer : ABCModel No. : EC−450HL5Serial No. : 1C375A003Scope ID : WHITEPatient ID : ABC123Physician ID : Dr. ShafferOperator ID : M.T.

Process Start : 12/06/11 12:08:41Process End : 12/06/11 12:38:42Total Time : 30:01Status : Completed

CIDEX OPA−C Concentrate MEC : Pass Expiry : Feb 2012 Lot No. : 140710/450 Available : 32 CyclesDetergent Exp.: Jan 2013Endoscope Leak Rate : 1.84 mBar/min

Stage Time−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−Leak Test 1 00:53Wash 10:54Disinfect 15:17 HLD Time 05:10 HLD Min Temp. 51.4 C HLD Requirements AchievedAlc. Flush 01:28Leak Test 2 01:27

Validated By :____________________

SAMPLE PRINTOUT

M.T.M.T.

Records patient, physician and operator IDs (optional feature)

Automated MEC monitoring eliminates the need for test strips and subjectivity of

human interpretation

Records the Operator that removed the endoscope

Verifies the high-level disinfection contact time and temperature

Endoscope information is automatically entered

The EVOTECH® ECR monitors critical cycle information, which is recorded and printed out for easy and accurate record keeping. It provides the most comprehensive documentation suggested by guidelines from leading organizations ie; SGNA, AORN and the Multisociety Guideline, 2011.

GET CONNECTEDwith Digital Transfer Interface (DTI)

DTI allows your EVOTECH® ECR to connect with your facility’s IT network. This network connection allows for automatic data transfer and storage of cycle records, improving and simplifying the process of data management.

Without DTI, you can manually access cycle data electronically via a USB stick for the previous 100 cycles

For complete product details, please see Instructions for Use.