45
Building Owners Roofing System Inspection and Maintenance

Building Owners Roofing System Inspection and Maintenance

  • Upload
    greg

  • View
    45

  • Download
    1

Embed Size (px)

DESCRIPTION

Building Owners Roofing System Inspection and Maintenance. Why Inspect and Maintain the Roofing System?. Periodic inspection and maintenance is needed in order for the roof to perform as designed . - PowerPoint PPT Presentation

Citation preview

Page 1: Building Owners  Roofing  System  Inspection and  Maintenance

Building Owners Roofing System Inspection and Maintenance

Page 2: Building Owners  Roofing  System  Inspection and  Maintenance

Why Inspect and Maintain the Roofing System?

• Periodic inspection and maintenance is needed in order for the roof to perform as designed.

• Inspection and maintenance is typically required by roofing manufacturers to keep roofing warranties in full force and effect.

Page 3: Building Owners  Roofing  System  Inspection and  Maintenance

Proactive vs Reactive Maintenance

• Reactive Maintenance: is a response to a existing problem:– Leaks– Repairs after damage due to weather events– Changes in the rooftop (relocated RTUs, new

adjacent construction, etc.)

Page 4: Building Owners  Roofing  System  Inspection and  Maintenance

Proactive vs Reactive Maintenance

• Proactive Maintenance: stopping potential problems before they impact the roofing system - can create significant savings and extend the service life of the roofing system:

The above cost analysis was prepared by a development firm owning in excess of 550 million square feet of commercial space.

Page 5: Building Owners  Roofing  System  Inspection and  Maintenance

When Should the Roof Be Inspected?

• Make a roof inspection plan part of the overall maintenance of the facility– Schedule regular inspections by on-site facility

management team– Schedule twice-annual inspections by Roofing

Professionals– Inspect following weather events (wind, hail,

etc.)– Inspect when leaks or damage occurs

Page 6: Building Owners  Roofing  System  Inspection and  Maintenance

Who Should Perform the Inspection?

• The local facility staff can perform casual inspections:– Observe and record the status of the roofing system.– Use data gathered to direct a Roofing Professional to

problem areas• A Roofing Professional should perform a

thorough inspection:– At least twice a year.– Whenever repairs is required.

Page 7: Building Owners  Roofing  System  Inspection and  Maintenance

Who Should Perform Maintenance?

• Local facility management staff: – Clean single-ply membranes– Remove debris, especially from

drains/scuppers/gutters– Locate areas of damage/leaks and safely mark them

• Roofing Professionals: – Repair leaks and perform reactive maintenance– Perform proactive maintenance– Provide estimates for future roofing maintenance

needs– Use manufacturer-licensed roofing contractors to protect your warranty

Page 8: Building Owners  Roofing  System  Inspection and  Maintenance

Inspection ChecklistsWhere to Look - What to Look For -

Remedial Actions

• Rooftop Traffic Areas• Contaminants• Drainage Components• Wind Storm Damage• Moisture Infiltration• Roof Membrane Seams• Base Attachments

Page 9: Building Owners  Roofing  System  Inspection and  Maintenance

Rooftop Traffic Areas• Where to Look:

– Roof Hatch area or roof access points– Walkways and “natural” paths– Mechanical Equipment

• What to Look For:– Cuts & punctures– Compressed/crushed insulation– Always monitor and log rooftop traffic

Displaced walkway pads

Page 10: Building Owners  Roofing  System  Inspection and  Maintenance

Rooftop Traffic Areas• Remediation:

– Emergency repair of cuts and punctures• Duct tape open areas of single-ply

membrane/flashing• Seal open asphalt membrane with plastic roof

cement• Cover repaired area with tarp if possible

– Permanent repair of cuts and punctures• Contact manufacturer’s licensed Roofing

Professional– Crushed insulation

• Have Roofing Professional replace with new insulation

Page 11: Building Owners  Roofing  System  Inspection and  Maintenance

Rooftop Traffic Areas

• Preventative Actions:– Add or enhance Roof Walkways– Register all rooftop traffic on a Roof Access

Log

Keep debris cleared!(…always remove ducks…!)

Page 12: Building Owners  Roofing  System  Inspection and  Maintenance

Contaminants

Membrane split

Membrane swelling

Page 13: Building Owners  Roofing  System  Inspection and  Maintenance

Contaminants• Where to Look:

– Kitchen Exhaust Fans– HVAC Compressors

Membrane swelling

Page 14: Building Owners  Roofing  System  Inspection and  Maintenance

Contaminants

• Remediation: – Membrane which has cracked, split, or swelled

should be replaced by a Roofing Professional• Preventative Actions:

– If grease traps are not present, consider installing grease traps

– If sacrificial layer of membrane is not present, consider installing additional layer over waterproofing layer

Page 15: Building Owners  Roofing  System  Inspection and  Maintenance

Drainage Components

Roof Drain & Overflow Drain blocked by debris

Open scupper flashings

Page 16: Building Owners  Roofing  System  Inspection and  Maintenance

Drainage Components

Blocked Drain Debris in gutter, broken gutter straps, open fastener holes

Page 17: Building Owners  Roofing  System  Inspection and  Maintenance

Drainage Components• Where to Look:• Mid-span of Roof Beams & Joists• Around Rooftop Units (RTUs)• At Drains, Scupper, Gutters, Downspouts

• What to Look For:• Debris• “Ponding,” Sagging, or Deflection• Discoloration at Curbs and Walls• Damage to Drainage Components

Page 18: Building Owners  Roofing  System  Inspection and  Maintenance

Drainage Components• Remediation:

– Remove Debris - bag and dispose– Drainage components – have Roofing Professional

replace defective drainage components and flash them, according to manufacturer’s approved details.

Blocked Drain

Page 19: Building Owners  Roofing  System  Inspection and  Maintenance

Drainage Components

• Preventative Actions:– Add roof drains– Add Tapered Insulation (“saddles and

crickets”)– Add a redundant layer of membrane

Page 20: Building Owners  Roofing  System  Inspection and  Maintenance

Wind Damage

Page 21: Building Owners  Roofing  System  Inspection and  Maintenance

Wind Damage

“Tented” and Backed-Out Fasteners

Displaced Insulation Boards

Page 22: Building Owners  Roofing  System  Inspection and  Maintenance

Wind Damage• Where to Look:

– Roof Edge – metal, gutters, downspouts– Rooftop Units– Roof Membrane surface– Flashings – metal and membrane flashings

Damaged Metal Coping

Page 23: Building Owners  Roofing  System  Inspection and  Maintenance

Wind Damage

What to Look For:• All Systems:

– Loose or missing sheet metal flashing components, especially at the roof edge

– Deflection or distortion of insulation boards– Large cuts or slices in the roof membrane

• Ballasted systems – displaced rock/pavers, displaced insulation boards under membrane

• Adhered systems – disbonded membrane, “tented” fasteners and plates

• Mechanically Attached systems – “tented” fasteners

Page 24: Building Owners  Roofing  System  Inspection and  Maintenance

Wind Damage

“Tented” Fasteners

Disbonded Membrane, Failed Base Attachments

Page 25: Building Owners  Roofing  System  Inspection and  Maintenance

Wind Damage

• Remediation:– Remove all debris– Replace any displaced ballast – carefully to

avoid puncture– Seal small cuts and punctures– Have Roofing Professional resecure detached

flashings and sheet metal– Have Roofing Professional make permanent

repairs to membrane and reinstall/replace displaced/damaged insulation

Page 26: Building Owners  Roofing  System  Inspection and  Maintenance

Wind Damage

Displaced Ballast

Damaged Metal Coping

Page 27: Building Owners  Roofing  System  Inspection and  Maintenance

Wind Damage

• Preventative Actions:– Add additional roof ballast to ballasted systems– Review roofing system design – have a Roof

Consultant, engineer, or architect review the design and recommend changes to protect against future wind damage

Page 28: Building Owners  Roofing  System  Inspection and  Maintenance

Moisture Infiltration• Where to Look:• Building Walls and Parapets• Large RTUs• Skylights

Moisture infiltrating around RTU

Page 29: Building Owners  Roofing  System  Inspection and  Maintenance

Moisture Infiltration• What to Look For:

– “Soft” Roof Insulation– Cracking, Spalling, or Discoloration of Walls– Loose Metal Wall Flashings– Covered “Weep Holes”– Missing or Broken Weather Seals on RTU s– Cracked or Sunken Sealants/Caulking

Page 30: Building Owners  Roofing  System  Inspection and  Maintenance

Moisture Infiltration• Remediation:

– Replace wet roof insulation (should only be performed by a Roofing Professional)

– Reattach and re-seal/caulk metal components (either by Roofing Professional or trade professional)

– Repair deteriorated walls, parapets, substrates (should be performed by trade professional)

Moisture stain on parapet wall

Page 31: Building Owners  Roofing  System  Inspection and  Maintenance

Moisture Infiltration• Preventative Actions:

– Have a Roof Consultant perform a Moisture Survey (Thermal Imaging, and/or core cuts)

– Keep RTUs sealed to manufacturer’s standards– Log access to roof by RTU/HVAC maintainers

Moisture Scan Image

Page 32: Building Owners  Roofing  System  Inspection and  Maintenance

Roof Membrane Seams• Where to Look:

– T-Joints (membrane panel intersections)

– Angle changes (such as deck-to-wall)

• What to Look For:– Edge cavitation– Entrapped

moisture

“Fishmouth” in seam

Page 33: Building Owners  Roofing  System  Inspection and  Maintenance

Roof Membrane Seams• Remediation (Emergency Repairs):

– Modified Bitumen (asphalt) Systems: • Apply plastic roof cement to the seam edge

– Single-Ply Systems: • Gently clean the area, then cover the seam edge with

duct tape extending 1.0” in all directions from seam opening

• Remediation (Permanent Repairs)– Should only be made by Roofing Professionals

Open Lap

Page 34: Building Owners  Roofing  System  Inspection and  Maintenance

Base Attachments

Membrane “Bridging”

Failed Base Attachment

Page 35: Building Owners  Roofing  System  Inspection and  Maintenance

Base Attachments

• Where to Look: – Parapet Walls and Equipment Curbs– Roof Edge

• What to Look For:– “Bridging” – membrane pulled away from the

90-degree angle change or greater than 2:12, forming an angled “bridge” from horizontal to vertical

– Loose or “Tented” Fasteners

Page 36: Building Owners  Roofing  System  Inspection and  Maintenance

Base Attachments• Remediation:

– Emergency Repair:• If a leak is present, seal

the area with duct tape (single-ply systems) or plastic roof cement (asphalt systems)

– Permanent repair: • Base Tie-In and

Membrane should be reattached and restored by a Roofing Professional

Membrane Bridging

Page 37: Building Owners  Roofing  System  Inspection and  Maintenance

Roofing Inspection Checklist for use by on-site Facilities Managers

• See Page 13 of the “Firestone Inspection, Repair, and Maintenance Guide” for a reproducible Roofing Inspection Checklist to carry to the rooftop.

• Checklist contains a brief description of what to look for in all of the above conditions.

• Note “Conditions Observed,” and “Actions Recommended” on the Checklist, along with the location of the problem area.

• Reference completed Checklist when contact Roofing Manufacturer to report a leak or problem with the roofing system.

Page 38: Building Owners  Roofing  System  Inspection and  Maintenance

Roofing Inspection Checklist

Page 39: Building Owners  Roofing  System  Inspection and  Maintenance

Guide to Common Repair Methods

• See the “Firestone Inspection, Maintenance, and Repair Guide,” Section II, for drawings and explanations of what quality repairs by a Roofing Professional should look like.

Page 40: Building Owners  Roofing  System  Inspection and  Maintenance

Service Requests/Leak Reports

• Firestone Warranty Services– 1-800-830-5612 - Line answered 24/7– Fax information to 1-317-575-7210– Email information to

[email protected]

Page 41: Building Owners  Roofing  System  Inspection and  Maintenance

Service Requests/Leak Reports

• Provide the following information:– Building Name and Address– Building Owner Name– Name of contact on-site, fax number, and phone

number – Warranty Number (printed on front of warranty)– Date when leak was observed– Description of leak or issue

Page 42: Building Owners  Roofing  System  Inspection and  Maintenance

Fax Notification Form

Page 43: Building Owners  Roofing  System  Inspection and  Maintenance

Warranted Repairs

• Firestone issues a “Warranty Service Work Order” to the original installing contractor.

• Building Owner or on-site contact is faxed an acknowledgement letter with roofing contractor’s contact information

• Contractor will investigate and complete necessary repairs within 10 working days

Page 44: Building Owners  Roofing  System  Inspection and  Maintenance

Non-Warranted Repairs

• Roofing System Warranties typically cover repair of leaks

• Most other conditions are non-warranted• Building Owner is responsible for payment of

investigation and repair of non-warranted conditions

Page 45: Building Owners  Roofing  System  Inspection and  Maintenance

Questions?