59
THE NATIONAL BUILDING CODE (CONDO) DE GUZMAN, SUSHMITA SEN C. GUERRIN, GLADYS ANNE MEJIA, ELAND JETHRO PUZON, DANE STEFI MARIE P. SANTOS, KITT TEMPLO, CHARMAINE Y.

Building Code presentation

Embed Size (px)

DESCRIPTION

101

Citation preview

Page 1: Building Code presentation

THE NATIONAL BUILDING CODE

(CONDO)DE GUZMAN, SUSHMITA SEN C.

GUERRIN, GLADYS ANNEMEJIA, ELAND JETHRO

PUZON, DANE STEFI MARIE P.SANTOS, KITT

TEMPLO, CHARMAINE Y.

Page 2: Building Code presentation

National Building Code of the Philippines

CLASSIFICATION AND GENERAL REQUIREMENTS OF ALL

BUILDINGS BY USE OR OCCUPANCYUSE OR OCCUPANCY UNIT AREA PER OCCUPANT

(Sq. m.)Minimum of Two Exits other than elevators are required

where number of occupant is over

A. Dwellings 28 10B. Hotels 18.6 10 Apartments 18.6 10 Dormitories 18.6 10

Page 3: Building Code presentation

National Building Code of the Philippines

GROUP ARESIDENTIA

L DWELLINGS

GROUP BRESIDENTIA

L, HOTEL, AND

APARTMENTS

OCCUPANCY TYPE• Section 701

• Section 702

No change shall be made in the character of occupancy of any building.

• Section 703

One-storey building with more than one occupancy each portion shall conform to the requirement of each.

Page 4: Building Code presentation

http://continuingeducation.construction.com/article.php

TYPES OF OCCUPANCY SEPARATION

1.) One – Hour Fire Resistive Operation

2.) Two – Hour Fire resistive Operation

3.) Three – Hour Fire Resistive Operation

4.) Four – Hour Fire Resistive Operation

Page 5: Building Code presentation

LOCATION ON PROPERTYNo buildings shall be constructed unless it adjoins a

street

National Building Code of the Philippines

Page 6: Building Code presentation

LOCATION ON PROPERTY

National Building Code of the Philippines

Page 7: Building Code presentation

LOCATION ON PROPERTY

National Building Code of the Philippines

Page 8: Building Code presentation

LOCATION ON PROPERTY

National Building Code of the Philippines

Page 9: Building Code presentation

MAXIMUM HEIGHT OF BUILDINGS

National Building Code of the Philippines

Page 10: Building Code presentation

MAXIMUM HEIGHT OF BUILDINGS

National Building Code of the Philippines

Page 11: Building Code presentation

MEASUREMENT AND PERCENTAGE OF SITE

OCCUPANCY

National Building Code of the Philippines

Page 12: Building Code presentation

MEASUREMENT AND PERCENTAGE OF SITE

OCCUPANCY

National Building Code of the Philippines

Page 13: Building Code presentation

MEASUREMENT AND PERCENTAGE OF SITE

OCCUPANCY

National Building Code of the Philippines

Page 14: Building Code presentation

SETBACK REQUIREMENT

National Building Code of the Philippines

YARDType of Residential Use / OccupancyR - 1(meters)

R - 2 R - 3 R - 4(individual lot / unit meters)

R - 5(meters)Basic

(meters)Maximum(meters)

Basic (meters)

Maximum(meters)

Front 4.50 3.00 8.00* 3.00 8.00* 4.50 6.00Side 2.00 2.00** 2.00** *** 2.00

(optional)2.00(optional)

3.00

Rear 2.00 2.00 2.00 *** 2.00 2.00 3.00

Page 15: Building Code presentation

PARKING REQUIREMENT

National Building Code of the Philippines

• 3.60m * 12.00m – bus/tracks

Page 16: Building Code presentation

PARKING REQUIREMENT

National Building Code of the Philippines

Page 17: Building Code presentation

PARKING REQUIREMENT

National Building Code of the Philippines3.70 M

1.20 M

Page 18: Building Code presentation

ELEVATOR

National Building Code of the Philippines

10.1 ACCESSIBLE ELEVATOR SHOULD BE LOCATED NOT MORE THAN 30.00 M FROM THE ENTRANCEAND SHOULD BE EASY TO LOCATE WITH THE AID OF SIGNS

10.2 ACCESSIBLE ELEVATORS SHALL HAVE A MINIMUM DIMENSION OF 1.10 M. x 1.4 M.

Page 19: Building Code presentation

National Building Code of the Philippines

CEILING HEIGHTS

Min. 2.40 m

Min. 2.70m

Min. 2.40 m

Min. 2.10 m

Page 20: Building Code presentation

National Building Code of the Philippines

CEILING HEIGHTS

MEZZANINE FLOORS

Min. 2.70 m

Stairways 1

Min. 1.80 m.

1st Floor w/ Natural Ventilation

Page 21: Building Code presentation

National Building Code of the Philippines

SIZE AND DIMENSIONS OF

ROOMSMin. Area = 1.20 sq. m0.90 m

Page 22: Building Code presentation

National Building Code of the Philippines

PWD BATHROOM

30 M40 M

80 M

CLE

AR

TU

RN

IN

GS

PAC

E1.5

0X

1.

50

Page 23: Building Code presentation

National Building Code of the Philippines

KITCHEN

Page 24: Building Code presentation

National Building Code of the Philippines

WINDOW OPENING

10 % FLOOR AREA

Page 25: Building Code presentation

National Building Code of the Philippines

ARCADE

ARCADE

MIN

. 3.0

0 M

Page 26: Building Code presentation

National Building Code of the Philippines

BUILDING PROJECTION OVER

PUBLIC STREETS

Page 27: Building Code presentation

CORRIDORS

National Building Code of the Philippines

3.4 A MINIMUM CLEAR LEVEL SPACE OF 1.50 M X 1.50 M SHALL BE PROVIDED BEFORE EXTENDING BEYOND A DOOR; EXCEPTION: WHERE A DOOR SHALL OPEN ONTO BUT NOT INTO A CORRIDOR, THE REQUIRED CLEAR, LEVEL SPACE ON THE CORRIDOR SIDE OF THE DOOR MAY BE A MINIMUM OF 1.20M CORRIDOR WIDTH

3.5) PROTECTION SHOULD BE PROVIDED FROM DOORS THAT SWING INTO CORRIDORS

Page 28: Building Code presentation

National Building Code of the Philippines

RAMPS

1.20 M (MIN)

MAX 6

.00

M

1:12 RATIO

Page 29: Building Code presentation

National Building Code of the Philippines

STAIRWAYS

A B

C

Page 30: Building Code presentation

National Building Code of the Philippines

STAIR LANDING

Max. 1.20 m

max. 3.60 m

Min. 2.00 m

Page 31: Building Code presentation

National Building Code of the Philippines

HAND RAIL

0.80 m < x > 0.90 m

3 m3 m

Page 32: Building Code presentation

National Building Code of the Philippines

EXITS

EXIT 1

Occupant load of more than 10

EXIT 2

OCCUPANT LOAD NO. OF EXITS

Above first storeyMore than 10

2

500-999 3

1000 or more 4

Total Width of Exits > total occupant load served / 165

Page 33: Building Code presentation

National Building Code of the Philippines

500 – 999 Occupant LoadExit 1

Exit 2

EXIT

EXIT

< 1/5

EXIT DISTANCES

Page 34: Building Code presentation

National Building Code of the Philippines

60

M M

AX

45 M MAX

EXIT

Page 35: Building Code presentation

National Building Code of the Philippines

MIN OF 1.10 MMAX OF 6 M

10.7 lux

Page 36: Building Code presentation

National Building Code of the Philippines

Hazardous Areas/ 50 or more load

MIN 900 MM

MIN

O

F 2

M

90`

DOOR EXIT

Page 37: Building Code presentation

NATIONAL BUILDING CODEOF THE PHILIPPINES(Mall)

DE GUZMAN, SUSHMITA SEN C.GUERRIN, GLADYS ANNEMEJIA, ELAND JETHRO

PUZON, DANE STEFI MARIE P.SANTOS, KEITH L.

TEMPLO, CHARMAINE Y.

Page 38: Building Code presentation

Building Occupancy•Group E:

▫Business & Mercantile

National Building Code of the Philippines

Page 39: Building Code presentation

National Building Code of the Philippines

Page 40: Building Code presentation

PARKING REQUIREMENTS

National Building Code of the Philippines

Building Type Number of parking slot

Markets 1 slot/150 sq.m. of shopping floor area

Restaurants, Fast-food centers, bars and beerhouses

1 slot/30 sq.m. of customer area

Office buildings 1 slot/125 sq.m. of gross floor area

Other buildings in business/ commercial zones

1 slot/125 sq.m. of gross floor area

Public assembly buildings (theaters, cinemas,

auditorium, stadium, etc.)

1 slot/50 sq.m. of spectators area

Building Type (Recreational Facilities)

Number of parking slot

Bowling Alleys 1 slot/4 alleys

Amusement center 1 slot/50 sq.m. of gross floor area

Page 41: Building Code presentation

PARALLEL PARKING

2.00m

6.00m

5.00m

2.40m

PERPENDICULAR PARKING

National Building Code of the Philippines

Page 42: Building Code presentation

Truck and Bus

3.60m

12.00m

2.40m

5.00m

Diagonal Parking National Building Code of the Philippines

Page 43: Building Code presentation

PARKING FOR PWD 1 accessible parking slot for the handicapped per 50 parking lots

up to 150 slots and an additional slot for every 100 slots Maximum distance of accessible parking area from facility served.

Parking areas for the physically handicapped shall be within 60.00m of the facility being served.

FACILITY SERVED

WALKWAY

PARKING SLOT

PARKING SLOT

PARKING SLOT

PARKING SLOT

PARKING SLOT

National Building Code of the Philippines

Page 44: Building Code presentation

90 DEG. PARKING BAY ONE SIDE

13.50m

3.00m

7.20m

ONE WAYTWO WAY

5.70m

2.55m to 2.70m

Planning and Designers Handbook (Second Edition)Max B. Fajardo Jr.

Page 45: Building Code presentation

90 DEG. PARKING BAY TWO SIDES

3.00m7.20m

ONE WAY TWO WAY

5.70m

2.55m to 2.70m

19.00m to 19.50m

Planning and Designers Handbook (Second Edition)Max B. Fajardo Jr.

Page 46: Building Code presentation

D A B C X Y Z

90 18.60

5.70 7.20 18.60

5.70 7.20

60 18.00

6.30 5.40 16.65

5.65 5.40

45 15.80

5.80 3.90 13.85

4.97 3.90Planning and Designers Handbook (Second Edition)

Max B. Fajardo Jr.

Page 47: Building Code presentation

R = 17.00m to 21.00m

4.00m to 4.50m

4.00m to 4.50m

R = 15.60m

to 19.00m

DN

UP

Planning and Designers Handbook (Second Edition)Max B. Fajardo Jr.

Page 48: Building Code presentation

Bus

Planning and Designers Handbook (Second Edition)Max B. Fajardo Jr.

7.60m3.00m

17.60m

2.70m

2.10m

Page 49: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads

C – 1: Exit Door shall swing in the direction of travel.Double Acting Doors shall not be used as exits.

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 50: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads

• C-3: Exit doorway shall be of a size as to permit the installation of a door not less than 900mm and not less than 2.00m in height

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 51: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads•C-5: Revolving, sliding, and overhead

doors shall not be used as required exits.

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 52: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads•D-1: Every corridor or exit balcony shall

not be less than 1.10 meters in width

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 53: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads• D-3: When more than one exit is required, they

shall be arranged to allow going to either direction from any point in the corridor.

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 54: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads• Corridors and exterior exit balconies with dead

ends are permitted when the dead end does not exceed 6.00 meters in length

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 55: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads• E-1: Stairway widths• Occupant Load (X) = Minimum Width X > 50 = 1100MM X < 50 = 900MM X < 10 = 750MMTrim and handrails shall not reduce the required width

by more than 100MM

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 56: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads• E-3: Winding stairways may be used if the

required width of the run is provided at a point not more than 300MM from the side where the treads are narrower.

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 57: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads• E-5: Every landing shall be a dimension measured in

the direction of travel equal to the width of the stairway. Such dimension need not exceed 1.20m when the stairs has a straight run.

NATIONAL BUILDING CODE OF THE PHILIPINES

Page 58: Building Code presentation
Page 59: Building Code presentation

Section 1207. Stairs, Exits, and Occupant Loads•K: Exits shall be illuminated at any time

the building is occupied.

NATIONAL BUILDING CODE OF THE PHILIPINES