17
BTS3900 Configuration Level: internal 2009-7-2 Page1, Total17 BTS3900 Configuration Guideline Drafted by Quan Kuifa Date JUN.10.2009 Reviewed by Date Approved by Date Huawei Technologies Co., Ltd. All rights reserved.

BTS3900 Configuration

  • Upload
    anna86

  • View
    872

  • Download
    80

Embed Size (px)

Citation preview

Page 1: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page1, Total17

BTS3900 Configuration Guideline

Drafted by Quan Kuifa Date JUN.10.2009

Reviewed by Date

Approved by Date

Huawei Technologies Co., Ltd.

All rights reserved.

Page 2: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page2, Total17

This guide instructs that how to configur BTS3900 in the BSC6000.also that how to implement BTS swap.All the operations is based on the LMT and MML. The content of this guide is as below: 1, Main process of BTS configuration 2, Alarm configuration for BTS 3, Data configuration for BTS swap

Page 3: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page3, Total17

1. Main process of BTS configuration Keep the same configuartion with site “Batna CCLT 05503” in the Batna. Step1: add site

Step2: add cell

Page 4: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page4, Total17

Step3: set attributes

Page 5: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page5, Total17

Step4: add FMU and GATM board (Each BTS3900 is configured with 6 DRFU.1 FMU.1 GATM.1 BBU.) Add FMU in slot 8 and GATM in slot 17, because the monitor signal cable of FMU and GATM are connected to “MON0” and “MON1” of UPEU separately.which keeps the confiuration same with the practical installation.

Page 6: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page6, Total17

Step5: add RXU Chain

Page 7: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page7, Total17

Use the RF cable connection tool to generate the connection. For the site 05503(S4/4/4) is as below:

Page 8: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page8, Total17

Step6: add RXU (RFU) Principia for RXU’s name: PortX_SlotX_PosX. PortX: Port No. X of GTMU SlotX: Slot No. X of DRFU PosX: Position No.X of the DRFU in the chain.

Keep confiuration same with the practical connection.Finally the RXU chain topo is as below.

Page 9: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page9, Total17

Step7: bind logical TRX From Trx No.0 to Trx No.11

Step8: Set TRX attributes (Send Receive Mode)

Page 10: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page10, Total17

Set the “Send Receive Mode” due to pratical situation. Because just one ANT port of DRFU is used, the “Single Antenna Double Receiver” is chosen.

Step9: Set cell attributes Almost the configuration process is same with BSC32. One parameter should be cared, which is”Power Type”. “20W” is chosen due to the Send Receive Mode.

Page 11: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page11, Total17

2. Alarm configuration for BTS3900 The BBU can support 2 RS485 bus and 16 line of on-off alarm maximally. There are just 1 UPEU configured in BTS3900 in the packeting list. The No. of on-off alarm for UPEU is as below.

The monitor signal of DCDU-01 is connected to No.8 alarm of EXT-ALM0 of UPEU. Step1: set site attributes

Step2: set Alarm Shield Flag 2 (Hex) The 8 bits (from low to high) of alarm sheild flag 2 determines the No.8-15 on-off alarm. 0 means “shield”, 1 means “non-shield”. The alarm sheild flag 2 is set as “01” to enable the DCDU-01 arlarm.

Page 12: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page12, Total17

Step3: set Alarm Voltage Definition

Page 13: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page13, Total17

Step4: set external alarm port Set the external alarm port for the on-off alarm of the UPEU as below.

Step5: name the external alarm Click the “Alarm Matintenance” in the LMT mean

Find the No.5048 alarm.then right-click it.choose as below.

Page 14: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page14, Total17

Set the Alarm name.

Page 15: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page15, Total17

3. Data configuration for BTS swap Step1: configure the site with LMT in offline mode Note: Configure the site on the same slot and port as the site to be swapped.

Step2: export the site data in offline mode

It will take about 5 minutes to export one site data. Step3: backup the data of the swapped site in online mode Note: do this after blocking the site.

Page 16: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page16, Total17

The exported result is the format of text as above, which will be used to edit the adjacent cell for BTS3900 later. Step4: delete the swapped site in online mode

Step5: import the data in online mode

Page 17: BTS3900 Configuration

BTS3900 Configuration Level: internal

2009-7-2 Page17, Total17

The log above indicates that importing is successful. Step6: edit the MML script Use the “UltraEdit” tool to edit the exported file named”BTS3900 adjacent cell” above. Comman”ADD CELL2GNC” will be used to add adjacent cell. It’s very to edit the MML script with the “UltraEdit” tool in column mode. Take care the”Bidirectional Adjacent Cell”and”Single directional Adjacent Cell”! For the the”Bidirectional Adjacent Cell”, command” ADD CELL2GNC” should be executed twice to add adjacent cell in both cell. Step7: execute the MML script in batch Log in the MML and execute the script”BTS3900 adjacent cell” in batch.