    DATA CENTER

    Brocade VDX/VCS Data Center

    Layer 2 Fabric Design Guide for Brocade

    Network OS v2.1.1

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    2/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 2 of 32

    CONTENTS

    Introduction..........................................................................................................................................................................................................................................4

    Building a Multi-Node VCS Fabric ................................................................................................................................................................................................4

    Design Considerations ....................................................................................................................................................4

    Topology....................................................................................................................................................................4

    Clos Fabrics..............................................................................................................................................................4

    Mesh Fabrics............................................................................................................................................................5

    VCS-to-VCS Connectivity ..........................................................................................................................................6

    Switch Platform Considerations..............................................................................................................................7

    Oversubscription Ratios ..........................................................................................................................................7

    Scalability .................................................................................................................................................................8

    Implementation ...............................................................................................................................................................8

    VCS Nuts and Bolts (Within the Fabric)...................................................................................................................................................................................10

    Deciding Which Ports to Use for ISLs...........................................................................................................................10

    ISL Trunking............................................................................................................................................................10

    Brocade ISL Trunk..................................................................................................................................................12

    Brocade Long Distance ISL ...................................................................................................................................12

    ECMP Load Balancing ...................................................................................................................................................12

    Configurable Load Balancing ................................................................................................................................12

    Operational Considerations...................................................................................................................................12

    Brocade VDX Layer 2 Features (External to Fabric) ...........................................................................................................................................................13

    Active-Standby Connectivity..........................................................................................................................................13

    Active-Active Connectivity..............................................................................................................................................13

    vLAG Enhancements .....................................................................................................................................................13

    vLAG Configuration Guidelines with VMware ESX Server and Brocade VDX.............................................................14

    vLAG Minimum Links.....................................................................................................................................................14

    LACP SID and Selection Logic.......................................................................................................................................14

    LACP SID Assignment....................................................................................................................................................14

    LACP Remote Partner Validation ..................................................................................................................................14

    Operational Consideration............................................................................................................................................15

    show lacp sys-id: ....................................................................................................................................................15

    Edge Loop Detection (ELD) ...........................................................................................................................................16

    Connecting the Fabric to Uplinks .................................................................................................................................16

    Upstream Switches with MCT................................................................................................................................16

    Upstream Switches Without MCT .........................................................................................................................16

    Connecting the Servers to Fabric..........................................................................................................................18

    Rack Mount Servers ..............................................................................................................................................18

    Blade Servers.........................................................................................................................................................18

    Manual Port Profiles ..............................................................................................................................................18

    Dynamic Port Profile with VM Aware Network Automation .................................................................................18

    Data Center Network and vCenter........................................................................................................................18

    Network OS Virtual Asset Discovery Process .......................................................................................................18

    VM-Aware Network Automation MAC Address Scaling........................................................................................19

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    3/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 3 of 32

    Authentication........................................................................................................................................................19

    Port Profile Management ......................................................................................................................................19

    Usage Restriction and Limits ................................................................................................................................19

    Third-Party Software ..............................................................................................................................................20

    User Experience .....................................................................................................................................................20

    Building a 2-Switch ToR VCS Fabric.........................................................................................................................................................................................21

    Design Considerations ..................................................................................................................................................21

    Topology..................................................................................................................................................................21

    Licensing.................................................................................................................................................................21

    Implementation......................................................................................................................................................21

    Building a 2-switch Aggregation Layer Using VCS..............................................................................................................................................................23

    Design Considerations ..................................................................................................................................................23

    Topology..................................................................................................................................................................23

    Licensing.................................................................................................................................................................23

    Implementation......................................................................................................................................................23

    Building the Fabric.................................................................................................................................................24

    24-Switch VCS Reference Architecture..................................................................................................................................................................................25

    Appendix A: VCS Use Cases........................................................................................................................................................................................................26

    VCS Fabric Technology in the Access Layer.................................................................................................................26

    VCS Fabric Technology in the Collapsed Access/Aggregation Layer .........................................................................27

    VCS Fabric Technology in a Virtualized Environment..................................................................................................28

    VCS Fabric technology in Converged Network Environments ....................................................................................29

    Brocade VDX 6710 Deployment Scenarios.................................................................................................................30

    Glossary..............................................................................................................................................................................................................................................31

    Related Documents ......................................................................................................................................................................................................................31

    About Brocade.................................................................................................................................................................................................................................32

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    4/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 4 of 32

    INTRODUCTION

    This document describes and provides high-level design considerations for deploying Brocade VCSFabric

    technology using the Brocade VDXseries switches. It explains the steps and configurations needed to deploy the

    following:

    A 6-switch VCS Fabric topology providing physical or virtual server connectivity with iSCSI/NAS

    A 2-switch Top of Rack (TOR) topology

    A 2-switch VCS topology in Aggregation, aggregating 1 GbE switches

    A 24-switch VCS topology

    The target audience for this document includes sales engineers, field sales, partners, and resellers who want to

    deploy VCS Fabric technology in a data center. It is assumed the reader of this document is already aware of the

    VCS Fabric technology, terms, and nomenclatures. Explaining the VCS nomenclature is beyond the scope of this

    document, and the reader is advised to peruse the publically available documents to become familiar with Brocade

    VCS Fabric technology.

    BUILDING A MULTI-NODE VCS FABRIC

    Design Considerations

    Topology

    Please note that for all illustrations, the Brocade MLXis shown as the aggregation switch of choice, which is the

    current Brocade recommendation. However, Brocade VCS is fully standards-compliant and can be deployed with any

    standards-compliant third-party switch.

    Multi-node fabric design is a function of the number of devices connected to the fabric, type of server/storage

    connectivity (1 GbE/10 GbE), oversubscription and target latency. There are always tradeoffs that need to be made

    in order to find the right balance between these four variables. Knowing the application communication pattern will

    help you tailor the network architecture to maximize network performance.

    When designing a fabric with VCS technology, which is topology agnostic, it is important to decide early in theprocess what the performance goal of the fabric is. If the goal is to provide a low-latency fabric with the most path

    availability, and scalability is not a priority, then full mesh is the most appropriate topology. However, if a balance

    between latency, scalability, and availability is the goal, then a Clos topology is more appropriate. There are multiple

    combinations possible in between these two, including partial mesh, ring, star, or other hybrid networks, which can

    be designed to handle the tradeoffs between availability and latency. However, Brocade recommends that either a

    full-mesh or a Clos topology be used to design VCS Fabrics to provide resilient, scalable, and highly available Layer 2

    fabrics.

    Multi-node fabrics have several use case models. Appendix 1 provides details of various such models for which

    multi-node fabrics are targeted. Up to and including Network OS v2.0.1, direct connectivity between two separate

    VCS fabrics is not supported. It is currently required that you place a L2/L3 switch as a hub with multiple VCS fabrics

    in a spoke, to prevent loops in a network.

    Clos Fabrics

    Figure 1 shows a two-tier Clos Fabric. Generally, the top row of switches acts as core switches and provides

    connectivity to the edge switches. A Clos Fabric is a scalable architecture with a consistent hop count (3 maximum)

    for port-to-port connectivity. It is very easy to scale a Clos topology by adding additional switches in either the core or

    edge. In addition, as a result of the introduction of routing at Layer 2 with VCS technology, traffic load is equally

    distributed among all equal cost multipaths (ECMP). There are two or more paths between any two edge switches in

    a resilient core-edge topology.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    5/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 5 of 32

    Figure 1:2-Tier Clos Fabric

    Mesh Fabrics

    Figure 2 shows a full-mesh fabric built with six switches. In a full-mesh topology, every switch is connected directly to

    every other switch. A full-mesh topology is a resilient architecture with a consistently low number of hop counts (2

    hops) between any two ports. A full mesh is the best choice when a minimum number of hops is needed and a

    future increase in fabric scale is not anticipated, since a change in mesh size can be disruptive to the entire fabric.

    For a mesh to be effective, traffic patterns should be evenly distributed with low overall bandwidth consumption.

    Figure 2:Full-Mesh Fabric

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    6/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 6 of 32

    VCS-to-VCS Connectivity

    VCS-to-VCS connectivity is supported in Network OS v2.1.0 release. VCS-to-VCS connectivity is supported for only a

    certain set of topologies, due to the lack of a loop detection mechanism. It is highly recommended that VCS-to-VCS

    connectivity be restricted to the following topologies only:

    ELD, which is available in Network OS v2.1.1, can be used as a loop detection mechanism between

    VCS fabrics. Prior to Network OS v2.1.1 the topology could not have any loops. Also, prior to NetworkOS v2.1.1, any local loop even within a single cluster caused broadcast storms and brought down the

    network. A local loop in one cluster impaced the other cluster.

    Two VCS clusters can be directly connected to each otherone at the access layer and the other at the

    aggregation layer.

    Figure 3:VCS-to-VCS Cluster

    One VCS cluster at the aggregation layer can be directly connected to up to 16 VCS clusters at the

    access layer; however, access clusters must notbe connected to each other.

    All links connecting to the two clusters must be a part of a single vLAG, and all multicast control traffic

    and data traffic should be limited to 10 Gbps within the vLAG. This limitation is due to the fact that

    there is no distribution of multicast trafficmulticast traffic is always sent out on a primary link.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    7/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 7 of 32

    Figure 4:VCS-to-VCS Cluster

    Switch Platform Considerations

    Brocade VCS Fabrics can be designed with the Brocade VDX 6720-24 (16/24 port), VDX 6720-60 (40/50/60 port)

    switches, VDX 6710 (48!1 GbE Copper + 6!10GbE SFP+), VDX 6730-32 (24!10 GbE SFP+, 8!8 GbE FC ports), and

    VDX 6730-76 (60!10 GbE SFP+, 16!8 GbE FC ports). The Brocade VDX 6720-24 switch provides a single ASIC-

    based architecture delivering constant latency of ~600ns port-to-port. The Brocade VDX 6720-60 switch is multi-

    ASIC based, with latencies ranging from 600 ns to 1.8 us. When designing a Clos topology, using the higher port

    count switches in the core enables greater scalability. The Brocade VDX 6710 provides cost-effective VCS fabricconnectivity to 1 GbE servers, while the Brocade VDX 6730 connects the VCS fabric to the Fibre Channel (FC)

    Storage Area Network (SAN).

    In addition, it is important to consider the airflow direction of the switches. The Brocade VDX is available in both

    port-side exhaust and port-side intake configurations. Depending upon the hot-aisle, cold-aisle considerations, you

    can choose the appropriate airflow.

    Please note that the Brocade VDX 6710 does not require Port On Demand (POD) or Fibre Channel over Ethernet

    (FCoE) License, and the VCS fabric mustbe through 10 GbE ports. However, 10 GbE ports may be used to connect

    to servers. These server-facing ports will not support Data Center Bridging (DCB). Lastly, VCS fabric is supported

    only with Brocade VDX 6710.

    Oversubscription Ratios

    Brocade VDX switches do not have dedicated uplinks. Any of the available 10 GbE ports can be used as uplinks to

    provide desired oversubscription ratios. When designing a mesh network, the oversubscription ratio is directly

    dependent on the number of uplinks and downlinks. For example, a 120-port, non-blocking mesh can be designed

    with four 60-port Brocade VDX switches. Each Brocade VDX switch has 30 downstream ports and 30 upstream ports

    (10 connected to each of three Brocade VDX switches). In this case, the oversubscription ratio is 1:1, as there are 30

    upstream ports serving 30 downstream ports. In the case of a two-tier Clos topology, there are two levels of

    oversubscription, if the fabric uplinks are connected to the core layer. For North-South traffic, oversubscription is the

    product of the oversubscription of core switches and edge switches. For example, if the core switch with 60 ports

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    8/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 8 of 32

    has 20 uplinks and 40 downlinks, then it has an oversubscription ratio of 2:1 (40:20). Furthermore, if the edge

    switch also has the same oversubscription, then the fabric oversubscription for North-South traffic is 4:1. For East-

    West traffic, or if the uplinks are also connected at the edge, the oversubscription is dependent only on the

    oversubscription of the edge switches, in other words, 2:1 in this example.

    Scalability

    When designing the fabric, it is important to consider the current scalability limits mentioned in the release notes of

    the software running on the switches. These scalability numbers will be improved in future software releases without

    requiring any hardware upgrades. This can be referenced in the release notes.

    The Brocade VDX series of switches allows for the creation of arbitrary network topologies. Because of this flexibility,

    it is not possible to cover all architectural scenarios. Therefore, the scope of this document is to provide a baseline

    of architectural models to give the reader a sense of what can be built.

    Implementation

    Now that the topology, switch, oversubscription, and other variables have been decided, you can decide how to build

    this network. As mentioned earlier, the Brocade VDX series of switches allows for the creation of arbitrary network

    topologies. Because of this flexibility, it is not possible to cover all architectural scenarios. Therefore, the scope of

    this document is to provide a baseline of architectural models, to give the reader a sense of what can be built. This

    document describes one such modelhow to build a core-edge network using 4!24 port edge switches and 2!24

    port switches in core with a 4:1 oversubscription ratio. This document discusses how to connect various types of

    servers and storage to this fabric and how to connect the fabric to upstream devices. Figure 5 shows the basic

    design of this topology, and Table 1 lists the equipment required for this design.

    Figure 5:Topology for Reference Architecture

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    9/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 9 of 32

    Hardware Quantity Comments

    BR-VDX 6720-24 (-F or R) 6 Network OS v2.1.0

    10G-SFPP-TWX-0508 24 (6x4) For ISLs

    10G-SFPP-TWX-0308 8 Depends on number of servers connected

    10G-SFPP-SR 32 (4x8) For Brocade VDX side, assuming that Brocade MLXalready has connectivity and fiber cables

    BR-VDX6720-24VCS-01 6

    BR-VDX6720-24FCOE-01 6

    iSCSI Initiators As needed

    iSCSI Targets As needed

    FCoE Initiators As needed

    FCoE Targets As needed

    Table 1:Equipment required for a 6-Switch VCS Fabric Solution

    The topology used in the above example is a sample topology. Brocade VCS fabrics can be built with a mix and match

    of any number of switches within the scalability limits of the software version running.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    10/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 10 of 32

    VCS NUTS AND BOLTS (WITHIN THE FABRIC)

    Deciding Which Ports to Use for ISLs

    Any port can be used to form an Inter-Switch Link (ISL) on the Brocade VDX series of switches. No special

    configuration is required to create an ISL. There are two port types supported on the Brocade VDX switchesedge

    ports and fabric ports. An edge port is used for any non-VDX-to-VDX connectivityregardless of whether that is a

    network switch external to the Brocade VDX when running in VCS mode or whether the port is used for end-device

    connectivity. A fabric port is used to form an ISL to another Brocade VDX switch and can participate within a Brocade

    VDX ISL Trunk Group.

    ISL Trunking

    When determining which ports to use for ISL Trunking, it is important to understand the concept of port groups on

    Brocade VDX switches, as shown in

    Figure 6. ISL Trunks can only be formed between ports of the same port group. In addition, the cable length should

    be the same to connect the ports forming the ISLs.

    Figure 6:Port Groups on the Brocade VDX 6720-60

    Figure 7:Port Groups on the Brocade VDX 6720-24

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    11/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 11 of 32

    Figure 8:Port Groups on the Brocade VDX 6710-54

    Figure 9:Port Groups on the Brocade VDX 6730-32

    Figure 10:Port Groups on the Brocade VDX 6730-76

    When building a fabric, it is very important to think in terms of ISL bandwidth. Brocade ISL Trunks can be formed

    using up to 8 links providing up to 80 Gbps of bandwidth. The throughput of ISLs are, however, limited to 80 mpps

    (million packets/sec), which results in lower bandwidth for small-size packets.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    12/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 12 of 32

    Once it has been decided which ports you will use to form an ISL, VCS needs to be enabled, and the RBridge ID must

    be defined. The VCS ID needs to be assigned for each switch that will become part of the fabric. The default VCS ID is

    1, and the default RBridge ID is 1. Keep in mind that it is disruptive to change these parameters, and a switch

    reboot will be required. During the reboot process, if there is no predefined fabric configuration, the default fabric

    configuration will be used upon switch bring-up. Once the switches are in VCS mode, connect the ISLs and the VCS

    fabric will form. Lastly, please also reference the section on Upgrade/Downgrade ConsiderationsVCS FabricFunctionality.

    Brocade ISL Trunk

    A Brocade Trunk is a hardware-based Link Aggregation Group (LAG). Brocade Trunks are dynamically formed

    between two adjacent switches. The trunk formation, which is not driven by Link Aggregation Control Protocol (LACP),

    is instead controlled by the same FC trunking protocol that controls the trunk formation on FC switches that use the

    Brocade Fabric OS (FOS). When connecting links between two adjacent Brocade VDX 6720s, Brocade Trunks are

    enabled automatically, without requiring any additional configuration. Brocade Trunking operates at Layer 2 and is a

    vastly superior technology compared to the software-based hashing used in standard LAG, which operates at Layer

    2. Brocade Trunking evenly distributes traffic across the member links on a frame-by-frame basis, without the need

    for hashing algorithms, and it can coexist with standard IEEE 802.3ad LAGs.

    Brocade Long Distance ISL

    Normally, an ISL port with Priority Flow Control (PFC) is supported for a 200 m distance on eAnvil-based platforms.

    The longdistance-isl command extends that support up to a distance of 10 km, including 2 km and 5 km links.

    For a 10 km ISL link, no other ISL links are allowed on the same ASIC. For 5 km and 2 km ISL links, another short-

    distance ISL link can be configured. A maximum of three PFCs (per Priority Flow Control) can be supported on a long-

    distance ISL port.

    To configure a long-distance ISL port, use the long-distance-islcommand in interface configuration mode.

    Please refer to the Network OS Command Reference and Network OS Administrators Guide, v2.1.1 formore

    information on long-distance (LD) ISL.

    ECMP Load Balancing

    Configurable Load Balancing

    Load balancing allows traffic distribution on static and dynamic LAGs and vLAG. Although it is not common, some

    traffic patterns fail to distribute, leading to only one ECMP path for the entire traffic. This causes underutilization of

    ECMP paths, resulting in a loss of data traffic, even though one or more ECMP paths are available to offload the

    traffic. In Network OS v2.1.0, a new command is introduced to configure ECMP load balancing parameters, in order

    to offer more flexibility to end users. This command allows users to select various parameters, which can then be

    used to create a hashing scheme. Please refer to the Network OS Administrators Guide, v2.1.1for more information

    on hashing scheme and usage guidelines.

    Operational Considerations

    The ECMP hash value is used to add more randomness in selecting the ECMP paths.

    The default value of ECMP hash is a random number, set during boot time.

    The default ECMP load balance hashing scheme is based on source and destination IP, MAC address,

    VLAN ID (VID), and TCP/UDP port.

    In the presence of a large number of traffic streams, load balancing can be achieved without any

    additional ECMP-related configuration.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    13/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 13 of 32

    VDX6720_1(config-rbridge-id-2)# fabric ecmpload-balance ?

    Possible completions:

    dst-mac-vid Destination MAC address and VID based load balancing

    src-dst-ip Source and Destination IP address based load balancing

    src-dst-ip-mac-vid Source and Destination IP and MAC address and VID based

    load balancingsrc-dst-ip-mac-vid-port Source and Destination IP, MAC address, VID and TCP/UDP

    port based load balancing

    src-dst-ip-port Source and Destination IP and TCP/UDP port based load balancing

    src-dst-mac-vid Source and Destination MAC address and VID based load balancing

    src-mac-vid Source MAC address and VID based load balancing

    VDX6720_2(config)# rbridge-id 2

    VDX6720_2(config-rbridge-id-2)# fabric ecmp load-balance dst-mac-vid

    VDX6720_2(config-rbridge-id-2)#

    VDX6720_2(config-rbridge-id-2)# fabric ecmp load-balance-hash-swap 34456

    VDX6720_2# show fabric ecmpload-balance

    Fabric EcmpLoad Balance Information

    ------------------------------------

    Rbridge-Id : 2

    BROCADE VDX LAYER 2 FEATURES (EXTERNAL TO FABRIC)

    Active-Standby Connectivity

    Active/Standby connectivity is used to provide redundancy at the link layer in a network. The most common protocol

    used at Layer 2 to provide Active/Standby connectivity is Spanning Tree Protocol (STP). The use of STP was

    historically acceptable in traditional data center networks, but as the densities of servers in data centers increase,

    there is a requirement to improve the bandwidth availability of the links by fully utilizing the available link capacity in

    the networks.

    Active-Active Connectivity

    MCT and vLAGMulti-Chassis Trunking (MCT) is an industry-accepted solution to eliminate spanning tree in L2

    topologies. Link Aggregation Group (LAG)-based MCT is a special case of LAG that is covered in IEEE 802.3ad, in

    which the LAG ends terminate on two separate chassis that are directly connected to each other. Virtual LAG (vLAG),

    a Brocade innovation, further extends the concept of LAG by allowing its formation across four physical switches that

    may not be directly connected to each other (but that participate in the same VCS fabric).

    vLAG Enhancements

    In Brocade Network OS v2.1, the vLAG feature is enhanced to remove several usage restrictions imposed in the

    previous Network OS releases. These are highlights of vLAG enhancement in Network OS v2.1:

    The ability to specify a minimum number of links that must be active on a vLAG before it can formaggregation is now supported in VCS mode. This was supported earlier only in standalone mode. The

    existing minimum-links Command Line Interface (CLI) under the port channel is now available in VCS

    mode.

    The ability to validate a remote partner for dynamic vLAG is also added.

    The maximum number of RBridges participating in a vLAG is now increased to 4.

    The maximum number of ports participating in a vLAG is 32, with 16 from a single RBridge.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    14/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 14 of 32

    vLAG Configuration Guidelines with VMware ESX Server and Brocade VDX

    VMware recommends configuring an EtherChannel when the admin chooses IP-based hashing as Network Interface

    Card (NIC) teaming. All other options of NIC teaming should use regular switch port configuration.

    vLAG Minimum Links

    The Minimum Links feature allows the user to specify the minimum number of links that must be active on the vLAG

    before the links can be aggregated. Until the minimum number of links is reached, the port channel shows protocol

    down. The default minimum number of links to form an aggregator is 1. The minimum link configuration allows the

    user to create vLAGs with a strict lower limit on active participating port members.

    As with all other port-channel configuration commands executed on a Brocade VCS operating in Fabric

    Cluster mode, the user is required to configure the new minimum link value on each RBridge participating in

    the vLAG. The port channel will be operationally down, if the number of active links in a vLAG falls below the

    minimum number of links required to keep the port channel logically up. Similarly, the port channel is

    operationally up when the number of active links in the vLAG becomes equal to the minimum number of

    links required to bring the port channel logically up. The events that trigger a link active count change are as

    follows: an active link going up or down, a link added to or deleted from a vLAG, or a participating RBridge

    coming back up or going down.

    Please note that only ports with the same speed are aggregated.

    LACP SID and Selection Logic

    As part of establishing dynamic LACP LAGs (or port channels), LACP PDU frames are exchanged between the switch

    and the end devices. The exchange includes a unique identifier for both the switch and the device that is used to

    determine which port channel a link should be associated with. In Network OS v2.1, additional support is added for

    selecting a unique and consistent Local SID (LACP System ID), which is shared between all RBridges that are

    connected to the same vLAG. This SID is unique for each switch in the VCS.

    During vLAG split and rejoin events, when the member RBridge leaves from and joins into the cluster, SID reselection

    logic is enhanced to support a knob to control split recovery.

    Split Recovery:In Network OS v2.1.0, with no-ignore-split, SID is derived using the actual MAC address of one of the

    participating RBridges (SID Master). So when a vLAG is formed, the SID from the first RBridge configured into thevLAG is used. If the RBridge that owns the SID of the vLAG leaves the cluster, a new SID is selected from the MAC of

    one of the other Rbridges, and vLAG converges again.

    No Split Recovery:In this mode, a VSID (Virtual SID)which is a unique identifier derived using the VCS ID, similar to

    Network OS 2.0is used as the LACP SID for the vLAG. Upon split, all RBridges continue to advertise the same VSID

    as their LACP SID. No reconvergence is needed when nodes leave or (re)join the vLAG in the VCS mode.

    LACP SID Assignment

    In Network OS v2.1.0, SID is no longer a virtual MAC address derived using the VCS ID; instead, it is the actual MAC

    address of the participating RBridges. This allows scaling of the maximum number of RBridges that can participate in

    a VLAG, from 2 to 16.

    LACP Remote Partner ValidationA vLAG members links in different RBridges sometimes may be connected to other standalone switches. In the

    previous Network OS releases, there was no validation of the remote partner information for a dynamic vLAG across

    the RBridges. The user had the responsibility to assure that the links in the dynamic vLAG were all connected to the

    same remote device and key. In Network OS v2.1.0, remote partner validation support is added, which ensures that

    the first received partner information is sent out to all member R0Bridges. If the vLAG has a member in another

    RBridge, the aggregation fails, and vLAG is not formed.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    15/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 15 of 32

    Operational Consideration

    To ensure that the RBridges that join the fabric (RB3 in Figure 11) pick up the partner state, the remote SID state for

    vLAGs is included in the local database exchange. The following show command provides information on the SID

    Master.

    show lacp sys-id:

    Port-channel Po 10 - System ID: 0x8000,00-05-33-8d-0e-25 - SID Master: rbridge-id 1 (ignore-split

    Disabled)

    Port-channel Po 20 - System ID: 0x8000,01-e0-52-00-00-13 - SID Master: N/A (ignore-split Enabled

    Default)

    Figure 11:SID Update on LACP Join

    If both RBridges are connected to the same remote device, the remote SID should match.

    Figure 12:LACP SID Assignment

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    16/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 16 of 32

    If the RBridges are configured for the same vLAG but are connected to different remote devices, the remote

    SID values do not match. Since the local SID state is forced to synchronize between the connecting

    RBridges, the side whose Local SID is forced to change ends up with disabled links.

    Edge Loop Detection (ELD)

    Edge Loop Detection (ELD) is a Brocade Layer 2 loop detection mechanism. It uses PDUs to detect loops in the

    network. This protocol is mainly intended for VCS-to-VCS loop prevention operation, but it can also be used in the

    VCS-to-standalone mode of networks.

    The ELD feature is implemented to block redundant links between two VCS fabrics: when a device detects a loop by

    receiving packets originated from it, it should disable all redundant links in that network. This is to prevent packet

    storm created due to loops caused by misconfiguration.

    The primary purpose of ELD is to block a Layer 2 loop caused by misconfiguration. ELD should be used as a tool to

    detect any loops in the network, rather than using it to replace Layer 2 protocols such as xSTP, Metro Ring Protocol

    (MRP), and so on.

    The basic ELD functionality is as follows: ELD is enabled on a specific port and VLAN combination. Each ELD-enabled

    interface on an RBridge sends an ELD PDU. This PDU contains information about the VCS ID and RBridge ID of the

    node it is sending from, the VLAN associated with this interface on which ELD is enabled, the ELD port priorityparameter, and so on. ELD can be configured on Access mode ports and Trunk mode ports, and PDUs follow port

    configuration for tagging. The port priority parameter decides which port will be shut down in case ELD detects a

    loop. These PDUs are transmitted from every ELD-enabled interface at the configured hello interval rate. When

    these PDUs are received back at the originating VCS, ELD detects a loop; this results in shutting down redundant

    interfaces based on the port parameter of the redundant links. If the port priority value is the same, then the

    decision is based on the port number.

    ELD uses the system MAC address of the primary RBridge of VCS with the multicast (bit 8) and local (bit 7) on. For

    example, if the base MAC address of the primary RBridge of VCS is 00e0.5200.1800, then the destination MAC

    address will be 03e0.5200.1800.

    Please refer to the Network OS Administrators Guide, v2.1.1for more information on ELD.

    Connecting the Fabric to Uplinks

    Upstream Switches with MCT

    In order to connect VCS to upstream servers with MCT, set up a normal LACP-based LAG on the MLX side (or

    equivalent core router), and vLAG will form automatically on the VDX side.

    Upstream Switches Without MCT

    When the upstream devices are not running MCT or cannot support MCT, there are two ways that fabric uplinks can

    be connected.

    Option 1:Form an EtherChannel between the Brocade VDX and upstream devices, as shown in Figure 13. In this

    case, standard IEEE 802.3ad-based port trunks are formed between the fabric and upstream network devices. This

    provids link level redundancy, but no node level redundancy. If a core Brocade VDX fails, all of the flows through the

    MLX/RX (Brocade BigIronRX Series) that are connected to that device have no path to reach the fabric.

    Option 2:Run STP on upstream devices with Active/Standby connections, as shown in Figure 14. Since VCS tunnels

    all the STP Bridge Protocol Data Units (BPDUs) through, this topology is ideal to provide both node level and link level

    redundancy. An important caveat to keep in mind here is that if there are more than two upstream switches

    connected to the fabric, Rapid STP (RSTP) will default to STP, since RSTP requires point-to-point connectivitywhich

    is not provided in the fabric.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    17/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 17 of 32

    Figure 13:Connecting Fabric Uplinks to Upstream Devices, Option 1

    Figure 14:Connecting Fabric Uplinks to Upstream Devices, Option 2

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    18/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 18 of 32

    Connecting the Servers to Fabric

    Rack Mount Servers

    This section describes how rack mount servers, either physical or virtual, can be connected to the Brocade

    VCS Fabric. When connecting to the fabric in DCB mode, it is important that flow control is enabled on the

    Converged Network Adapters CNAs.

    Blade Servers

    When connecting blade servers to a VCS Fabric, there are two connectivity optionsembedded switches and pass-

    through modules. Please consult Brocade support to validate the supported solution. Not all qualified solutions

    have been published as of the release of this document.

    Manual Port Profiles

    Automatic Migration of Port Profiles (AMPP) is a Brocade innovation that allows seamless movement of virtual

    machines within the Ethernet fabric. In todays networks, network parameters such as security or VLAN settings

    need to be physically provisioned before a machine is moved from one physical server to another within the same

    Layer 2 domain. Using the distributed intelligence feature, a VCS fabric is aware of the port profiles associated with

    the MAC address of a Virtual Machine (VM) and automatically applies those policies to the new access port that the

    VM has moved to. Since AMPP is MAC address based, it is hypervisor-agnostic and works with all third-partyhypervisors.

    In Network OS v2.1.0, AMPP is supported over vLAG.

    Dynamic Port Profile with VM Aware Network Automation

    Server virtualization (VMs, and so forth) is used extensively in current datacenter environments, with VMware being

    the dominant player in datacenter virtualization. The server hosts (VMware ESXs) are connected directly to the

    physical switches throughswitch-ports(or edge-portsin the case of VCS). Many of these server hosts implement an

    internal switch, called vSwitch, which is created to provide internal connectivity to the VMs and a distributed switch

    that spans across multiple Server-Hosts. A new layer called the Virtual Access Layer (VAL) virtualizes connectivity

    between the physical switch and virtual machine via vSwitch or dvSwitch. VAL is not visible to the physical switch;

    thus, these VMs and other virtual assets remain hidden to the network administrator. The Brocade VM-aware

    network automation provides the ability to discover these virtual assets. With VM-aware network automation, aBrocade VDX 67XX switch can dynamically discover virtual assets and offer unprecedented visibility of dynamically

    created virtual assets.

    VM-aware network automation also allows network administrators to view these virtual assets using the Network OS

    CLI. VM-aware network automation is supported on all the Brocade VDX platforms and can be configured in both VCS

    and standalone mode. This feature is currently supported on VMware vCenter 4.0 and 4.1.

    Data Center Network and vCenter

    In current datacenter environments, vCenter is primarily used to manage Vmware ESX hosts. VMs are instantiated

    using the vCenter user interface. In addition to creating these VMs the server administrator also associates these

    with VSs (Virtual Switches), PGs (Port Groups), and DVPGs (Distributed Virtual Port Groups). VMs and their network

    properties are primarily configured and managed on the vCenter/vSphere. Many VM propertiessuch as MAC

    addressesare automatically configured by the vCenter, while some propertiessuch as VLAN and bandwidthareassigned by vCenter through VAL.

    Network OS Virtual Asset Discovery Process

    The Brocade switch that is connected to hosts/VMs needs to be aware of network policies in order to allow or

    disallow traffic. In Network OS v2.1.0, the discovery process starts upon boot-up, when the switch is preconfigured

    with the relevant vCenters that exist in its environment. The discovery process entails making appropriate queries to

    the vCenter. The queries are in the form of Simple Object Access Protocol (SOAP) requests/responses sent to the

    vCenter.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    19/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 19 of 32

    Figure 15:Virtual Asset Discovery Process

    VM-Aware Network Automation MAC Address Scaling

    In Network OS v2.1.1, the VM-aware network automation feature is enhanced to support 8000 VM MAC addresses.

    VM-aware network automation is now capable of detecting up to 8000 VM MACs and supporting VM mobility of this

    scale within a VCS fabric.

    Authentication

    In Network OS v2.1.1, before any discovery transactions are initiated, the first order of transactions involves

    authentication with the vCenter. In order to authenticate with a specific vCenter, the following vCenter properties are

    configured at the switchURL, Login, and Password. A new CLI is added to support this configuration.

    Port Profile Management

    After discovery, the switch/Network OS enters the port profile creation phase, where it creates port profiles on the

    switch based on discovered DVPGs and port groups. The operation creates port profiles in the running-config of the

    switch. Additionally, Network OS also automatically creates the interface/VLANs that are configured in the port

    profiles, which also end up in the running-config.

    The AMPP mechanism built into Brocade switches may provide a faster way to correlate the MAC address of a VM to

    the port it is associated with. Network OS continues to allow this mechanism to learn the MAC address and associatethe port profile with the port. The The vCenter automation process simply enhances this mechanism by providing

    automatic creation of port profiles or preassociating the MAC addresses before the VM is powered up.

    Usage Restriction and Limits

    Network OS creates port profiles automatically based on discovered DVPGs or port groups. The port profiles created

    in this way contain the prefix auto- in their names. The user is urged not to modify the policies within these port

    groups. If the user modifies these port profiles, the discovery mechanism at some point may overwrite the changes

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    20/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 20 of 32

    the user made. The user is also urged never to create port profiles whose names begin with auto- via CLI or from a

    file replay.

    The maximum number of VLANs that can be created on the switch is 3583, and port profiles are limited to 256

    profiles per switch. A vCenter configuration that exceeds this limit leads to an error generated by Network OS.

    Third-Party SoftwareTo support the integration of vCenter and Network OS, the following third-party software is added in Network OS

    v2.1.0:

    Open Source PHP Module

    Net-cdp-0.09

    Libnet 1.1.4

    User Experience

    sw0# show vnetwork hosts

    Host VMNic Name Associated MAC (d)vSwitch Switch-

    Iface

    ============================== ============= ================= ========================

    esx4-248803.englab.brocade.com vmnic2 5c:f3:fc:0c:d9:f4 dvSwitch-1

    0/1

    esx4-248802.englab.brocade.com vmnic2 5c:f3:fc:0c:d9:f6 dvSwitch-2

    0/2

    sw0# show vnetwork vms

    VirtualMachine Associated MAC IP Addr Host

    =============== ================= =========== =================================

    RH5-078001 00:50:56:81:2e:d5 192.168.5.2 esx4-248803.englab.brocade.com

    RH5-078002 00:50:56:81:08:3c - esx4-248803.englab.brocade.com

    Please refer to the Network OS Administrators Guide, v2.1.1for more information on VM-Aware Network

    Automation.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    21/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 21 of 32

    BUILDING A 2-SWITCH TOR VCS FABRIC

    Traditionally, at the access layer in the data center, servers have been configured with standby links to Top of Rack

    (ToR) switches running STP or other link level protocols to provide resiliency. As server virtualization increases the

    density of servers in a rack, the demand for active/active server connectivity, link-level redundancy, and multi-

    chassis EtherChannel for node-level redundancy is increasing. A 2-switch, ToR VCS Fabric satisfies each of these

    conditions with minimal configuration and setup.

    Design Considerations

    Topology

    The variables that affect a 2-switch ToR design are oversubscription, the number of ports required for server/storage

    connections, and bandwidth (1/10 GbE). Latency is not a consideration here, as only a single switch is traversed

    (under normal operating conditions), as opposed to multiple switches.

    Oversubscription, in a 2-switch topology, requires a simple ratio of uplinks to downlinks. In a 2!60 port switch ToR

    with 4 ISL links, 112 usable ports remain. Of these 112 ports, if 40 are used for uplink and 80 for downlink,

    oversubscription will be 2:1. However, if the servers are dual-homed in an active/active topology, there only 40

    servers will be connected, with 1:1 oversubscription.

    LicensingVCS will operate in a 2-switch topology without the need to purchase additional software licenses. However, if FCoE

    support is needed, a separate FCoE license must be purchased.

    For VCS configurations that exceed two switches, VCS licenses are required to form a VCS fabric. In addition, if FCoE

    is required, an FCoE licensein addition to a VCS licenseis required.

    Implementation

    Figure 16 shows a sample topology using a 2!60 switch Brocade VDX 6720 configuration. This topology

    provides 2.5:1 oversubscription and 80 server ports to provide active/active connectivity for a rack of 50

    servers and/or storage elements. Table 2 shows the Bill of Materials (BOM).

    Hardware Quantity Comments

    BR-VDX 6720-60 (-F or R) 2 Network OS v2.1.0

    10G-SFPP-TWX-0108 4 For ISLs

    10G-SFPP-SR 10 For uplinks on the VDX side

    BR-VDX6720-24FCOE-01 2 N/A

    iSCSI Initiators As needed

    iSCSI Targets As needed

    FCoE Initiators As needed

    FCoE Targets As needed

    Table 2:Equipment Required for a 2-Switch ToR Solution

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    22/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 22 of 32

    Figure 16:2-Switch ToR VCS

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    23/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 23 of 32

    BUILDING A 2-SWITCH AGGREGATION LAYER USING VCS

    At the aggregation layer in the data center, ToR switches have traditionally had standby links to ToR switches running

    STP, or other link level protocols, to provide resiliency. As server virtualization increases the density of servers in a

    rack, the demand for bandwidth from the access switches must increase, to reduce oversubscription. This in turn

    drives the demand for active/active uplink connectivity from ToR switches. This chapter discusses the best practices

    for setting up a two-node VCS Fabric for aggregation, which expands the Layer 2 domain without the need for

    spanning tree.

    Design Considerations

    Topology

    The variables that affect a 2-switch design are oversubscription and latency. Oversubscription is directly dependent

    on the number of uplinks, downlinks, and ISLs. Depending upon the application, latency can be a deciding factor in

    the topology design.

    Oversubscription, in a 2-switch topology, is a simple ratio of uplinks to downlinks. In a 2!60 port switch Fabric with 4

    ISL links, 112 usable ports remain. Any of these 112 ports can be used as either uplinks or downlinks to give the

    desired oversubscription ratio.

    Licensing

    VCS operates in a 2-switch topology without the need to purchase additional software licenses. However, if FCoE

    support is needed, a separate FCoE license must be purchased.

    For VCS configurations that exceed 2 switches, VCS licenses are required to form a VCS fabric. In addition, if FCoE is

    required, an FCoE license in addition to a VCS license is required.

    Implementation

    Figure 17 shows a sample topology using a 2!60 switch Brocade VDX 6720. This topology provides a 2.5:1

    oversubscription and 80 downlink ports to provide active/active connectivity to 20 Brocade FCX 648 switches with

    4!10G uplinks each. Each of these Brocade FCX switches have 48x1G downlink ports, providing 960 (48!20) !1G

    server ports. Table 3 shows the BOM.

    Hardware Quantity Comments

    BR-VDX 6720-60 (-F or R) 2 Network OS v2.0.1

    10G-SFPP-TWX-0108 4 For ISLs

    10G-SFPP-TWX-0108 80 For Brocade FCX Uplinks

    10G-SFPP-SR 10 For uplinks on VDX side

    FCX-648 E or I 20 For 1 GbE server connectivity

    Table 3:Equipment List for a 2-Switch Aggregation Solution

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    24/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 24 of 32

    Figure 17:2-Switch VCS Fabric in Aggregation

    Building the Fabric

    Please refer to the VCS Nuts and Bolts (Within the Fabric) section. The same best practices apply to a 2-

    switch ToR solution.

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    25/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 25 of 32

    24-SWITCH VCS REFERENCE ARCHITECTURE

    Figure 18:24-Switch Brocade VCS Reference Architecture with 10 GbE Server Access

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    26/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 26 of 32

    APPENDIX A: VCS USE CASES

    Brocade VCS fabric technology can be used in multiple places in the network. Traditionally, data centers are built

    using three-tier architectures with access layers providing server connectivity, aggregation layers aggregating the

    access layer devices, and the data center core layer acting as an interface between the campus core and the data

    center. This appendix describes the value that VCS fabric technology delivers in various tiers of the data center.

    VCS Fabric Technology in the Access Layer

    Figure 19 shows a typical deployment of VCS Fabric technology in the access layer. The most common deployment

    model in this layer is the 2-switch ToR, as discussed previously. In the access layer, VCS fabric technology can be

    inserted in existing architectures, as it fully interoperates with existing LAN protocols, services, and architecture. In

    addition, VCS Fabric technology delivers additional value by allowing active-active server connectivity to the network

    without additional management overhead.

    At the access layer, VCS Fabric technology allows 1 GbE and 10 GbE server connectivity and flexibility of

    oversubscription ratios, and it is completely auto-forming, with zero configuration. Servers see the VCS ToR as a

    single switch and can fully utilize the provisioned network capacity, thereby doubling the bandwidth of network

    access.

    Figure 19: VCS Fabric Technology in the Access Layer

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    27/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 27 of 32

    VCS Fabric Technology in the Collapsed Access/Aggregation Layer

    Traditionally, Layer 2 (L2) networks have been broadcast-heavy, which forced the data center designers to build

    smaller L2 domains to limit both broadcast domains and failure domains. However, in order to seamlessly move

    virtual machines in the data center, it is absolutely essential that the VMs are moved within the same Layer 2

    domain. In traditional architectures, therefore, VM mobility is severely limited to these small L2 domains.

    Brocade has taken a leadership position in the market by introducing Transparent Interconnection of Lots of Links(TRILL)-based VCS Fabric technology, which eliminates all these issues in the data center. Figure 20 shows how a

    scaled-out self-aggregating data center edge layer can be built using VCS Fabric technology. This architecture allows

    customers to build resilient and efficient networks by eliminating STP, as well as drastically reducing network

    management overhead by allowing the network operator to manage the whole network as a single logical switch.

    Figure 20:VCS Fabric Technology in the Access/Aggregation Layer

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    28/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 28 of 32

    VCS Fabric Technology in a Virtualized Environment

    Today, when a VM moves within a data center, the server administrator needs to open a service request with the

    network admin to provision the machine policy on the new network node where the machine is moved. This policy

    may include, but is not limited to, VLANs, Quality of Service (QoS), and security for the machine. VCS Fabric

    technology eliminates this provisioning step and allows the server admin to seamlessly move VMs within a data

    center by automatically distributing and binding policies in the network at a per-VM level, using the Automatic

    Migration of Port Profiles (AMPP) feature. AMPP enforces VM-level policies in a consistent fashion across the fabric

    and is completely hypervisor-agnostic. Figure 21 shows the behavior of AMPP in a 10-node VCS fabric.

    Figure 21:VCS Fabric Technology in a Virtualized Environment

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    29/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 29 of 32

    VCS Fabric technology in Converged Network Environments

    VCS Fabric technology has been designed and built ground-up to support shared storage access to thousands of

    applications or workloads. VCS Fabric technology allows for lossless Ethernet using DCB and TRILL, which allows

    VCS Fabric technology to provide multi-hop, multi-path, highly reliable and resilient FCoE and Internet Small

    Computer Systems Interface (iSCSI) storage connectivity. Figure 22 shows a sample configuration with iSCSI and

    FCoE storage connected to the fabric.

    Figure 22:VCS Fabric Technology in a Converged Network

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    30/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 30 of 32

    Brocade VDX 6710 Deployment Scenarios

    In this deployment scenario, the Brocade VDX 6710s (VCS fabric-enabled) extend benefits natively to 1 GbE servers.

    Figure 23:Brocade VDX 6710 Deployment Scenario

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    31/32

    DATA CENTER DESIGN GUIDE

    Brocade VDX/VCS Data Center Layer 2 Fabric Design Guide for Brocade Network OS v2.1.1 31 of 32

    GLOSSARY

    BPDU Bridge Protocol Datagram Unit

    ELD Edge Loop Detection protocol. Used on the edge ports of a VCS fabric to detect and

    remove loops.MAC Media Access Control. In Ethernet, it refers to the 48-bit hardware address.

    PDU Protocol Datagram Unit

    RBridge Routing Bridge. A switch that runs the TRILL (Transparent Interconnection of Lots of

    Links protocol.

    RSTP Rapid Spanning Tree Protocol. An IEEE standard for building a loop-free LAN (Local-Area

    Network), which allows ports to rapidly transition to forwarding state.

    VCS Virtual Cluster Switching. BrocadeVCSFabric technology is a method of grouping a

    fabric of switches together to form a single virtual switch that can provide a transparent

    bridging function.

    vLAG Virtual Link Aggregation Group. You can create a LAG using multiple switches in a VCS

    fabric. vLAG provides better high availability and faster protection switching than a normalLAG.

    VLAN Virtual LAN. Subdividing a LAN into logical VLANs allows separation of traffic from

    different sources within the LAN.

    xSTP An abbreviation used in this document to indicate all types of Spanning Tree Protocol, for

    instance, STP, RSTP, MSTP (Multiple STP), PVST+ (Per VLAN Spanning Tree Plus), and

    RPVST+ (Rapid PVST+).

    RELATED DOCUMENTS

    For more information about Brocade VCS Fabric technology, please see the Brocade VCS Fabric Technical

    Architecture:

    http://www.brocade.com/downloads/documents/technical_briefs/vcs-technical-architecture-tb.pdf

    For the Brocade Network Operating System Admin Guide and Network OS Command Reference:

    http://www.brocade.com/downloads/documents/product_manuals/B_VDX/NOS_AdminGuide_v211.pdf

    http://www.brocade.com/downloads/documents/product_manuals/B_VDX/NOS_CommandRef_v211.pdf

    The Network OS Release notes can be found at http://my.brocade.com

    For more information about the Brocade VDX Series of switches, please see the product Data sheets:

    Brocade VDX 6710 Data Center Switch:

    http://www.brocade.com/products/all/switches/product-details/vdx-6710-dc-switches/index.page Brocade VDX 6720 Data Center Switch:

    http://www.brocade.com/products/all/switches/product-details/vdx-6720-dc-switches/index.page

    Brocade VDX 6730 Data Center Switch:

    http://www.brocade.com/products/all/switches/product-details/vdx-6730-dc-switches/index.page

  • 7/13/2019 Brocade VDX VCS Data Center Layer 2 Fabric Design Guide for Network OS

    32/32

    DATA CENTER DESIGN GUIDE

    ABOUT BROCADE

    As information becomes increasingly mobile and distributed across the enterprise, todays organizations are

    transitioning to highly virtualized infrastructure, which often increases overall IT complexity. To simplify this process,

    organizations must have reliable, flexible network solutions that utilize IT resources whenever and wherever

    neededenabling the full advantages of virtualization and cloud computing.

    As a global provider of comprehensive networking solutions, Brocade has more than 15 years of experience indelivering Ethernet, storage, and converged networking technologies that are used in the worlds most mission-

    critical environments. Based on the Brocade One strategy, this unique approach reduces complexity and disruption

    by removing network layers, simplifying management, and protecting existing technology investments. As a result,

    organizations can utilize cloud-optimized networks to achieve their goals of non-stop operations in highly virtualized

    infrastructures where information and applications are available anywhere.

    For more information, visit www.brocade.com.

    2012 Brocade Communications Systems, Inc. All Rights Reserved. 04/12 GA-DG-434-00

    Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, MLX, SAN Health, VCS, and VDX are registered trademarks, and AnyIO,

    Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network are trademarks of Brocade

    Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may

    be trademarks of their respective owners.

    Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any

    equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this

    document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may

    not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data

    contained in this document may require an export license from the United States government.