13
Boise STD REV to ISPWC 2013 00820 - 1 08/28/2013 BOISE CITY STANDARD REVISIONS FOR ISPWC DIVISION 1102 STREET LIGHTS GENERAL INFORMATION All work shall conform to the requirements of the 2012 Edition of the Idaho Standards for Public Works Construction (ISPWC), the Supplementary Conditions and these Standard Revisions. Contractor shall become familiar with these documents to ensure full understanding of the requirements of this Project. Failure to do so does not relieve the Contractor of the duties, obligations and responsibilities addressed within those documents. The Idaho State Electrical Board has determined that all street lights are to be provided with an external fuse disconnect, in a junction box between the power source and the street light pole. See attached standard drawings for connection requirements. Street light installations inspections will be required for the concrete base reinforcing, the trench depth and bedding, and for the pole. Contact City of Boise at 384-3900 for inspections, 48 hour notice required. Contractor shall notify the City when street light is ready for turn on. Attachment A lists approved products for Boise City street light installations. Contact Boise street light staff to seek approval for any substitute products. REVISIONS TO THE STANDARD SPECIFICATIONS SECTION 1102 STREET LIGHTING PART 2 MATERIALS 2.2 JUNCTION BOXES 2.2.A Replace with the following: Junction boxes in driveways or roadways to be concrete with traffic rated lid. 2.2.B Replace with the following: Junction boxes in sidewalks and similar ares to be concrete with steel lid. Add the following: 2.2.C Junction boxes in landscape areas may be plastic or fiberglass. 2.2.D All junction boxes to have a means to secure lid (i.e.bolt).

BOISE CITY STANDARD REVISIONS FOR ISPWC - City of … · A. Historical style metal poles shall be true copies, ... (see standard drawing BC SD-8). ... contact Boise Street Light staff

Embed Size (px)

Citation preview

Boise STD REV to ISPWC 2013 00820 - 1 08/28/2013

BOISE CITY STANDARD REVISIONS

FOR ISPWC DIVISION 1102 STREET LIGHTS

GENERAL INFORMATION All work shall conform to the requirements of the 2012 Edition of the Idaho Standards for Public Works Construction (ISPWC), the Supplementary Conditions and these Standard Revisions. Contractor shall become familiar with these documents to ensure full understanding of the requirements of this Project. Failure to do so does not relieve the Contractor of the duties, obligations and responsibilities addressed within those documents. The Idaho State Electrical Board has determined that all street lights are to be provided with an external fuse disconnect, in a junction box between the power source and the street light pole. See attached standard drawings for connection requirements. Street light installations inspections will be required for the concrete base reinforcing, the trench depth and bedding, and for the pole. Contact City of Boise at 384-3900 for inspections, 48 hour notice required. Contractor shall notify the City when street light is ready for turn on. Attachment A lists approved products for Boise City street light installations. Contact Boise street light staff to seek approval for any substitute products. REVISIONS TO THE STANDARD SPECIFICATIONS SECTION 1102 STREET LIGHTING PART 2 MATERIALS 2.2 JUNCTION BOXES 2.2.A Replace with the following: Junction boxes in driveways or roadways to be concrete with traffic rated lid. 2.2.B Replace with the following: Junction boxes in sidewalks and similar ares to be concrete with steel lid. Add the following: 2.2.C Junction boxes in landscape areas may be plastic or fiberglass. 2.2.D All junction boxes to have a means to secure lid (i.e.bolt).

Boise STD REV to ISPWC 2013 00820 - 2 08/28/2013

2.2.E See Attachment A for approved products. 2.3 FUSE HOLDERS

A.1. Add the following sentence. Fuses for Boise City installation shall be fast acting – 100k RMS Amps-

600VAC.

B.1. Add the following sentence. Fuses for Boise City installation shall be fast acting – 100k RMS Amps-

600VAC.

2.7 DISCONNECT BOXES Add paragraph D D. Disconnect boxes are only required for overhead wiring. 2.8 MAST ARMS FOR WOOD POLES NOT USED FOR BOISE CITY

INSTALLATIONS. 2.9 WOOD POLES NOT USED FOR BOISE CITY INSTALLATIONS. 2.10 METAL POLES Add the following paragraph:

F. Poles may be square, round or tapered round. Decorative poles are prohibited. Poles for decorative fixtures (approved by the City) are to be round. See Attachment A for approved poles for decorative fixtures.

2.11 FIBERGLASS POLES NOT USED FOR BOISE CITY INSTALLATIONS 2.12 HISTORICAL POLES Replace with the following:

A. Historical style metal poles shall be true copies, approved by Boise City, Department of Public Works, of the original Old Boise Historical Pole. The new historical poles shall have the same surface texture and have the same Dark Green or Black Green color finish that matches the existing Historical poles in the Historical Lighting District. Metal poles shall have a powder coat finish in accordance with ASTM B-117.

Boise STD REV to ISPWC 2013 00820 - 3 08/28/2013

B. Historical poles for the City of Boise shall be cast aluminum, in style and texture of the original Old Boise Historical Pole (see standard drawing BC SD-8). See Attachment A for approved products.

C. Color: To match existing poles, approved color mix for Valspar Anti-Rust gloss, oil enamel paint, base #4, #49437: mixture formula; 114-1Y29.44, 101-4Y42.9, 103-4Y14.55. Color designate for Antique is DGRG, for Continental it is RAL 6009.

D. Additional pole requirement for historic lights installed within the Capitol City Development Corporation (CCDC) shall be:

1. Poles shall be supplied with an electrical outlet as shown on standard drawing BC

SD-8. 2. Poles shall be supplied with a manufacturer’s adaptor for installation of the

approved banner arms. 2.13 BOLLARDS NOT USED FOR BOISE CITY INSTALLATIONS. 2.15 PREFABRICATED BASES NOT USED FOR BOISE CITY INSTALLATIONS. 2.16 SERVICE PEDESTAL Add the following: M. See Attachment A for approved products. 2.17 LIGHT FIXTURES Replace paragraphs A., B. and F. with the following:

A. Fixture wattage as required by Boise City Public Works. See Attachment A for approved products.

PART 3 WORKMANSHIP

3.2 CONDUIT INSTALLATION

A. Underground: Modify item 5 to read: “Locating wires only required for conduit in which the conductors are not installed in conjunction with the conduit.” Add the following item:

Boise STD REV to ISPWC 2013 00820 - 4 08/28/2013

9. For historical street lights within the Capital City Development areas, an additional, parallel conduit shall be installed from the street light to the control cabinet to accommodate a separate circuit for the outlets on the poles.

3.6 DISCONNECT BOXES NOT USED FOR BOISE CITY INSTALLATIONS. 3.7 GROUNDING Add to paragraph C. reference to City of Boise standard drawing BC SD-9 3.8 POLE INSTALLATION In paragraph B., delete reference to wood poles. Add reference to City of Boise standard drawing BC SD-11. In paragraph C., add reference to City of Boise standard drawing BC SD-8 Historical Pole.

G. NOT USED FOR BOISE CITY INSTALLATIONS 3.11 SERVICE PEDESTAL In paragraph B., Add the following sentence: Service pedestals connected to historical street lights shall conform to SD-1126 with an additional meter connected to the electrical outlet circuit. See Attachment A for approved products. ADDITIONAL CITY OF BOISE STANDARD DRAWINGS BC SD-8 HISTORICAL POLE DETAIL BC SD-9 HISTORICAL POLE BASE DETAIL BC SD-11 HISTORICAL STREET LIGHT PLACEMENT

8/14/2013

ATTACHMENT A APPROVED PART NUMBER LISTING

FOR CITY OF BOISE STREET LIGHTING

The following is an approved part number listing for the City of Boise for public street lighting. All lighting projects within the City of Boise and the City of Boise Area of Impact shall use these products or an approved equal. Contact the City of Boise Public Works Street Light Office at (208) 388-4719 to seek approval for products not listed below (approved equal). Part numbers listed for fixtures are basic and may not indicate the correct color or other features you need. Please verify part numbers with the vendors to ensure you are getting what you want to include the correct mounting hardware and color for your application. Street light requirements including type, wattage, and pole height will be established by Boise Street Light staff.

STANDARD LIGHT FIXTURES (Poles per standard specifications)

50 Watt Class – Equal to or greater than 4400 Lumens 90 Watt Class – Equal to or greater than 9100 Lumens

OPTION 1 - COBRA HEAD LIGHT FIXTURES

Manufacturer Part Number AUTOBAHN SERIES ATB0

50 Watt class - 48 watts - ATB0 30BLED53 MVOLT R3

Manufacturer AUTOBAHN SERIES ATB2 Part Number 90 Watt class - 91 watts – ATB2 40BLED70 MVOLT R3

8/14/2013

Manufacturer Part Number Cooper Streetworks OVH & OVF (B bar only) 50 Watt class - 51 watt - OVHB02LEDEUT3AP4 90 Watt class - 95 watt - OVHB04LEDEUT3 AP4

Manufacturer Part Number Cree XSP1 ( high efficacy only )

50 Watt class - 53 watt - BXSPAO3GA-USFR

Manufacturer Part Number Cree XSP2 ( high efficacy only )

90 Watt class - 101 watt - BXSPAO3HA-USFR

Manufacturer Part Number Cree Beta (525ma driver only)

50 Watt class - 67 Watt - STR-LWY-3M-HT-04-D-UL-SV-525-43KFR 90 Watt class - 120 Watt - STR-LWY-3M-HT-07-E-UL-SV-525-40KFR

Manufacturer Part Number LEOTEK ECobra-head LED Light

50 Watt class - 54 watt - EC1-6M-MV-NW-700-3-GY 90 Watt class - 123 watt - EC4-14M-MV-NW-700-3-GY

8/14/2013

Option 2 - SHOEBOX LIGHT FIXTURES

Manufacturer Part Number Cooper Lumark RV Ridgeview (B bar only) 50 Watt class - 51 watt - LDRV-T3-B02-E-PERBZ 90 Watt class - 95 watt - LDRV-T3-B04-E-PERBZ

Manufacturer Part Number Leotek Arieta LED 50 Watt class - 51 watt - AR18-6M-MV-NW-3-DB-PCR 90 Watt class - 97 watt - AR18-15M- MV-NW-3-DB-PCR

Manufacturer Part Number Lithonia Lighting Contour Series KAD LED 50 Watt class - 58 watt -

KADLED49B350/40KSR3MVOLTSPD04DDBXD 90 Watt class - 110 watts

KADLED63B530/40KSR3MVOLTSPD04DDBXD

HISTORICAL LIGHTS

HISTORIC LIGHT POLES: Includes pole, capitol adapter (if applicable); FG-S duplex GFCI outlet; breakaway banner arm; lower eyelet 51” below banner arm; and custom hand hole cover w Boise City Logo. Manufacturer Part Number Antique Street Lamps PA B-120 12-6 3T3 CLD107811 EBB FG-S 601810 BAB25B4 BBA BI

DGRG Continental Pole & Lighting ID20-FT12-ID21-BA, RAL 6009, Fluted-Cast Aluminum Pole w/ capitol

integral to the pole (no capitol required)

8/14/2013

HISTORIC LIGHT FIXTURES AND GLOBES:

Manufacturer Part Number Cooper Lighting LED Fixture GRANVIL-50-E-1 Continental Pole & Lighting Glass Globe ID21-C445 Type 3

Manufacturer Part Number Holophane LED Fixture (if ordered separately from glass globe)

GVDRETRO 60 5K AS A U 5

Holophane Globe (if ordered separately from LED fixture) Granville GV3N Glass Holophane Glass Globe and LED Fixture: if ordering both new LED fixture and glass globe

GVD 60 5K AS A DGRG 3 N N U

DECORATIVE LIGHTS (To be used at Developer’s option as an alternative to standard fixtures;

contact Boise Street Light staff in advance to discuss)

DECORATIVE LIGHT POLES:

Manufacturer Used With Part Number Cooper Lighting (25 Foot) Cooper INVUE fixture SRX5M25SBK4 Arm for 25 foot pole VA6154-BK

8/14/2013

Cooper Lighting (30 Foot) Cooper INVUE fixture SRX6M30SBK4 Arm for 30 foot pole VA6154-BK KW Pole (25 foot) ELH22 Hanover Pedant RSP25-4-11 BLK4-3/8 11T Arm for 25 foot pole EAJ4/1 ANBK PER KW Pole (30 foot) ELH22 Hanover Pedant RSP30-5-11 BLK4-3/8 11T Arm for 30 foot pole EAJ5/1 ANBK PER DECORATIVE LIGHT FIXTURES:

Manufacturer Part Number Cooper INVUE (B bar only) 50 Watt Class - 51 watt – ECM-B02-LED-E1-T3-SO-BK Must use solid mid section 90 Watt Class - 93 watt – ECM-B04-LED-E1-T3-SO-BK and bell shade

Manufacturer Part Number Antique street Lamps ELH22 Hanover Pedant

50 Watt Class - EHL22RT49LED530MA4KGFCMVOLTR3SPDDBL

UNDERPASS LIGHT FIXTURES

Manufacturer Part Number Cooper Streetworks Valet LED (B bar only)

50 Watt Class - 51 watt – VALB02LEDEUGL3APSTMB 90 Watt class - 93 watt – VALB04LEDEUGL3APSTMB

8/14/2013

Manufacturer Part Number Holophane TunnelPass LED 90 Watt class - 123 watt-TNLED 3 4K 1 AS CCB DGRA L

METERED SERVICE CABINETS Metered service cabinets shall at a minimum contain all the items listed in the ISPWC Standard

Drawings. All approved products below are 48 inches tall but vary in width.

SINGLE METER CABINETS Manufacturer Part Number Milbank 24 inch wide 240 Volt CP3B11113BWBOISE_ 277 Volt CP3B1181FBWBOISE_ Milbank 16 inch wide 240 Volt CP3B11113AWBOISE_ Myers 20 inch wide 240 Volt MEUG20-M100-4CK-Boise DUAL METER SERVICE CABINETS Manufacturer Part Number Milbank 24 inch wide 240 Volt CP3B22124BWBOISE_ Myers 24 inch wide 240 Volt MEUG24-M100/M100-4CK-Boise

JUNCTION BOXES

SIDEWALK/ROADWAY AREA JUNCTION BOXES Manufacturer Use Location Part Number Idaho Precast Concrete Sidewalks S-40T Roadways / Driveways S-40T ADA

LANDSCAPED/GRASS AREA JUNCTION BOXES Manufacturer Use Location Part Number

Carson Industries Landscaped Areas (9” Round) Carson 910-10-4BE Landscaped Areas (19”x 14”) Carson 1419-12-4BE