44
BMC Medical Co., Ltd. Nov. 2011 Training Course

BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

Embed Size (px)

Citation preview

Page 1: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

BMC Medical Co., Ltd.

Nov. 2011

Training Course

Page 2: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

2

Table of Contents

1.CATALOGUE

2.INSTALL& DISASSEMBLE

3.SET UP

Page 3: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

3

1. CATAOLGUE

Page 4: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

4

RESmart AutoCPAP (APAP)

Page 5: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

5

2. INSTALL & DISASSEMBLE

Page 6: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

Install

Heater Plate

Indicator Light

Outlet Port

Water Chamber

Fill Line

Install Water tank

Page 7: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

Component : Water tank, Humidifier, Device.

1

2

3

Page 8: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

Disconnect the tubing from the water chamber. Press down on the water chamber and slide it out of the humidifier platform.

Open the silica gel cover of water chamber and discard any remaining water.

Fill a solution of warm water and a mild dishwashing detergent into the chamber, cover the silica gel cover, rock the chamber a few minutes, then outflow the solution. Rinse the chamber several times with clean water and allow to air dry.

Fill the water chamber and close the silica gel cover. Inspect the water chamber for any leaks or damage.

Replace the water chamber if any damage is present.

Clearing Water tank

Page 9: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

DISASSEMBLE

Open the cover of the filter carefully. And then take it out.

Page 10: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

DISASSEMBLE

Press the button at the bottom of the main machine, then pull the heated humidifier.

Page 11: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

SET UP

3. SET UP

A. USER SET UP

B. MAINTENANCE SET UP

Page 12: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

SET UP

Control Button

Page 13: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP

AutoCPAP USER SET UP

.ENTER USER MENU

Page 14: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Verify/Change the RESmart USER settings. To start the setup menu, press and hold the Ramp button until the setup menu appear (about 5 seconds) when system standby.

IMPORTANT! Press the Ramp Button to enter change status and press +/- User Buttons to change the setting. Press Ramp Button again to confirm the setting.

Press +/- User Buttons to access the next setting.

Page 15: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Setting the Humidifier When the optional InH2™ Heated Humidifier is used, this setting can change the temperature and humidity of airflow between level 0 to 5. Default setting is 3.

Page 16: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Setting the Altitude The altitude setting can be changed between level 0 to 2. Default setting is 0.

0 = less than 2,460 ft. (<750 m)

1 = 2,460 to 4,921 ft. (750 m to 1500 m)

2 = 4,924 to 8,202 ft. (1501 m to 2500 m)

*over 8,202 ft. = The airflow pressure may not be accurate. Contact your home care provider to have your pressure setting adjusted.

Page 17: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Setting Auto ON When the RESmart Auto is standby and wearing mask, your deep breath will start airflow automatically. Default setting is Enable.

Page 18: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Setting Auto Off When the mask is removed, the RESmart Auto will stop airflow automatically. Default setting is Disable.

Note: We advice you can set Auto Off is Disable. Most machine may appear this kind of problem, because apnea and mask off  is not to be judged at pressure lower than 7 hpa.

Page 19: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Setting the LCD Light This setting allows you to adjust the LCD light among Auto, On and Off. Default setting is Auto.

Auto: LCD light will be turned on when any button pressing and turned off after few seconds.

On: LCD light will be turned ON always.

Off: LCD light will be turned OFF always.

Page 20: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Setting the Alert

This setting allows you to turn on/off the patient disconnect alert. When a large, continuous air leak (such as mask removal) has been detected in the circuit, this setting enables/disables the audible alert (a beeping sound). This setting is only effective when the Auto Off setting is disabled. Default setting is Disable.

Page 21: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Setting the Reslex The Reslex setting displays the Reslex level set by your home care provider. This setting allows you to adjust the level of air pressure relief that you feel when you exhale during therapy. Your home care provider may have already set a Reslex level. If this is not comfortable for you, you can increase or decrease the setting. The setting of “1” provides a small amount of pressure relief. To increase the pressure relief, change the setting to “2” or “3”. Default setting is 0 (disable).

Page 22: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Reslex working:

Page 23: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Delay Off Setting When the optional InH2™ Heated Humidifier is on, the machine will continue working for about 15 minutes at a very low pressure (about 2hPa) after RESmart Auto was turned off. This function will blow off the left vapor inside and protect the machine. Default setting is Enable.

Page 24: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Sensitive Setting The Sensitive Setting is only available on Auto CPAP mode. This setting can be set from 1(At level 1, the treatment pressure will increase slowly) to 5(More faster than level 1). Default setting is level 3.

Page 25: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Date Setting The current date is displayed and can be modified if needed.

Note: Check and confirm this Date Setting frequently to ensure the usage blog is correct.

Page 26: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Use Days The number of nights the RESmart Auto was used for therapy for more than 4 hours will appear. This screen is only for reference. Your home care provider may periodically ask you for this information.

Page 27: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

iCode

It is an information code. Default setting is Disable.

If you set enable. You will see using information with 1,7,30,90,182,365 day when you serially press Heated Humidifier Button on standby . The information include P95 pressure, AHI, SNI and mean pressure.

iCode need to be translated by RESmart iCode software.

Page 28: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Exit the Settings The settings are complete. Press the +/- user button to access the SAVE setting and Ramp Button to save all changes and exit the settings menu.

Page 29: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

AutoCPAP MAINTENANCE SETUP

ENTER SETUP MENU

Page 30: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Entering the Menu:

Power off the machine

Press and hold the Pressure Start/Stop Button and Ramp Button while connecting the power cord into the AC inlet. After several seconds the Maintenance Menu will appear on display screen as below.

Mode CPAP

Page 31: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

IMPORTANT! Press the Ramp Button to enter change status and press +/- User Buttons to change the setting. Press Ramp Button again to confirm the setting.

Press +/- User Buttons to access the next setting as below.

Page 32: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Auto mode:

Treat PMax APAPRampInit PUnitUse Time Mask test Save

Titrate mode:

Treat PMax APAPRampInit PUnitUse Time Mask test Save

CPAP mode:

Treat PManual PRampInit PUnitUse Time Mask test Save

Page 33: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Treat Pressure:

On Auto mode, this pressure is minimum pressure.

On Titrate mode, this pressure is set as the prescription pressure or less.

On CPAP mode, this pressure is the prescription pressure after ramp time.

Setting range is 4-20hPa. Adjustment step is 0.5hPa. Default setting is 8hPa.

Page 34: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

AutoCPAP’s operation on Auto mode

The pressusre will change from ‘Treat P’ to ‘Max APAP’

Page 35: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

AutoCPAP’s operation on Titrate mode

The pressusre change from ‘Init P’ to ‘Max APAP’

Page 36: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SETUP

Max APAP:

This setting is the maximal pressure which AutoCPAP system can reach. Default setting is 16hPa. Note: this setting is not effective on CPAP mode.

Page 37: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Manual Pressure:

This setting is only available on CPAP mode. This setting allows user to adjust APAP pressure by himself. Setting range is 0-2cm H2O. Adjustment step is 0.5cm H2O. Default setting is 0.

For example: If this setting is 1cm H2O and Treatment Pressure setting is 8cm H2O, user may change the treatment pressure between 7-9cm H2O by pressing +/- User Button.

Page 38: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Ramp Timer:The ramp time is from starting pressure to prescription pressure. Setting range is 0-60mins. Adjustment step is 5mins. Default setting is 15mins. The pressure will not change during the ramp time (initial pressure).

Page 39: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Ramp Starting Pressure:

The starting pressure after blower is turned on. Setting range is 4hPa to Treatment Pressure. Adjustment step is 0.5cm H2O. Default setting is 4cm H2O.

Init P 4.0

Ramp Starting Pressure

Page 40: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SET UP

Unit:

The unit of the output pressure, selectable between hpa and cmH2O.

Page 41: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SETUP

Use Time: Total hours this RESmart has been used will appear. This number is only for reference.

Page 42: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoPAP SETUP

Mask Test : This function is used to calibrate the exhaust flow of mask

which is not provided by BMC. Connect the RESmart device to mask with tube and seal the cushion, which is the patient interface of mask by hand. Press the Ramp button to start the self-test. RESmart device will start the blower and calibrate the exhaust flow of the mask. The self-test lasts for about 1 minute. The blower will stop after the self-test is finished. During the self-test, make sure that there is no leak between the hand and the cushion.

Page 43: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

AutoCPAP SETUP

Save and Exit: The settings are complete. Press the +/- user button to access the SAVE setting and press Ramp Button to save all changes and exit the Maintenance Menu.

IMPORTANT! To make all changes active, press the +/- User Button to access the SAVE setting and Ramp Button to save all changes and exit the Maintenance Menu.

Page 44: BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

Hide function

The device can be read using information(AHI,SNI, compliance, P95 and Mean P )of last night, when you press Ramp button then press + or – button at the device standby mode.(1.79 version later)

44