Bio-Rad Laboratories B I O P L E X 2 2 0 0 S Y S T E M
Like no other. The first and only fully-automated, random access, multiplex testing platform
BioPlex® 2200 System
Bio-Rad Laboratories
Forget limitations.Leveraging the power of multiplex testing, the BioPlex® 2200 System brings limitless workflow improvement to your laboratory. You’ve heard about the promise and future potential of multiplex technology…now Bio-Rad has made that promise a reality.
BioPlex® 2200System
FullyAutomated
RandomAccess eFlex
Software™
SuperiorChemistry
MultiplexTechnology
HighThroughput
B I O P L E X 2 2 0 0 S Y S T E M
Each microsphere is dyed with a uniquecombination of 2 colors
Up to 25color-codedmicrospheres(bead regions),can be bound with a unique antigen
The ANA Screen Reagent Pack uses 16 microspheres: 13 assay beads
and 3 quality control checks
1
5
8
11 13
2
6
9 10
12
3
7
4
A B C
1 dsDNA 2 Chromatin 3 Ribosomal P 4 SS-A (52 kD)* 5 SS-A (60 kD)* 6 SS-B 7 Sm 8 Sm/RNP 9 RNP (A)* 10 RNP (68)* 11 Scl-70 12 Jo-1 13 Centromere B
13 assay microspheres
3 quality control microspheres
A Serum Verification Bead (SVB) B Internal Standard Bead (ISB) C Reagent Blank Bead (RBB)
Patented Multiplex Detection Magnetic Bead TechnologyBioPlex® 2200 immunoassays use heterogeneous sets
ofmagnetic8µmbeads.Thebeadsareinfusedwith
varyingratiosoffluorescentdyes,creatinguniquebead
sets. Beads within each set are coated with a ligand
(i.e.,antigen,antibody,analyte,etc.)specifictoa
particular assay. Bead sets are then mixed together in
a single reagent pack allowing for simultaneous
detection of multiple analytes from a single sample.Each microsphere is dyed with a uniquecombination of 2 colors
Up to 25color-codedmicrospheres(bead regions),can be bound with a unique antigen
The ANA Screen Reagent Pack uses 16 microspheres: 13 assay beads
and 3 quality control checks
1
5
8
11 13
2
6
9 10
12
3
7
4
A B C
1 dsDNA 2 Chromatin 3 Ribosomal P 4 SS-A (52 kD)* 5 SS-A (60 kD)* 6 SS-B 7 Sm 8 Sm/RNP 9 RNP (A)* 10 RNP (68)* 11 Scl-70 12 Jo-1 13 Centromere B
13 assay microspheres
3 quality control microspheres
Example: ANAScreenKit
*IndividualSS-AandRNPresultsnot available in theU.S.Reportedas SS-AandRNPfor a total of 11 individual results.
Disease Focused Multiplex Panel MenuCurrently, multiplex panels are available or in development for the following disease-state areas:
•Autoimmune
•Serology/InfectiousDiseases
•SpecialtyImmunoassay
Leveraging the Power of Fully-Automated, Random Access, Multiplex Testing
• UtilizestheconceptofLeanManagementfora more streamlined workflow, improved turn-around times and decreased labor costs in your laboratory
• Reductionoferrorsthroughautomationanddirect connection to your LIS
• Abilitytoprogram3rdparty,Non BioPlex® 2200 controls that uses the same data management module as BioPlex® 2200 Quality Controls
• MultiplexTechnologyallowsforelectronicadd-on, from the same panel, of tests that were not part of the initial request, thus eliminating the need to place the sample back on the system
• Remoteconnectivityforbetterservice,including the monitoring of instrument logs so Bio-Rad can proactively support your system
Detection MethodThedual-laser,multiplexflowdetectionmethodprocesses
a minimum of 150 individual bead results for each analyte,
representingmorethan150assayreadings.Thisenhances
theoverallqualityofeachresult,whencomparedtostandard
immunoassays which rely on a single reading.
Detection1
Asampleofthefinalreactionmixtureisaspiratedtothedetector.
Quality Assurance with IQ Bead™ TechnologyEverysampleprocessedontheBioPlex® 2200
Systemwillhaveuptothreeremarkable
internalqualitycontrolbeadsaddedto
dramaticallyimprovethequalityandaccuracy
of assay results:
Serum Verification Bead (SVB)*
Confirmsthe presenceofserum/plasma
InternalStandardBead(ISB)*
Appearsineverytubetostandardize
detector performance
Reagent Blank Bead (RBB)*
Identifiessampleproblemsarisingfrom
non-specific binding
* Panel dependent
Detection2
Bead mixture passes through the detector where one laser identifies the bead analyte and another measures the analyte concentration.
Detection3
Thesystemdetectorperformsaminimumof150measurementsper analyte at the rate of 100,000 measurements per minute.
1
A minimum of150
measurementsper analyte100,000
measurementsper minute!
2
3
The BioPlex® 2200 System combines the diagnostic power of proprietary multiplex chemistry, a state-of-the-art software package, and the benefits of full automation and random access capability…all brought together to bring a new level of flexibility and operational benefits to your laboratory.
System BenefitsFully Automated/Random Access
• Improvedworkflowefficiency
• Decreasedhands-ontime
• Improvedturnaroundtimefortestresults
• Increasedtestingcapacity
• Fewererrorsfromspecimenandreagenthandling
State-of-the-Art eFlex™ Software
• Intuitivetouchscreenuserinterface
• LISConnectivityusingHostQueryor
BroadcastDownload
• Maintenancecalendartotrackdaily,weekly,
monthly and as needed tasks
• ExpansiveQCmoduleforcustomizingQCrules,tracking
BioPlex®2200Systemaswellas3rdpartycontrolsand
evaluatingnewQClotswithacalculationofthemeanandSD
prior to implementation
• RunChecklisttoverifythereareenoughreagentpackson-board
to complete the programmed run
• ExportofQCresultsdirectlytoBio-Rad’sUnityRealTime®
program
Innovative Multiplex Chemistry
• QualityassurancewithintegratedQCtechnologiesineverytest
• Proprietarymagneticbeadchemistryforsuperiorperformance
• Liquid,ready-to-usereagents,calibratorsandcontrols
For further information, please contact the Bio-Rad office nearest you or visit our website at www.bio-rad.com/diagnostics
Clinical Diagnostics Group
© 2012 Bio-Rad Laboratories, Inc. Printed in USA 08/12 DG12-0974 T-100
Website www.bio-rad.com/diagnostics U.S. 1-800-224-6723 Australia 61-2-9914-2800 Austria 43-1-877-8901 Belgium 32-9-385-5511 Brazil 5521-3237-9400 Canada 1-514-334-4372 China 86-21-61698500 Czech Republic 420-241-430-532 Denmark +45-4452-1000 Finland 358-9-804-22-00 France 33-1-47-95-60-00 Germany +49-(0)89-318-840 Greece 30-210-7774396 Hong Kong 852-2789-3300 Hungary +36-1-459-6100 India 1800-180-1224 Israel 972-3-9636050 Italy +39-02-216091 Japan 81-3-6361-7070 Korea 82-2-3473-4460 Mexico +52 (55) 5488-7670 The Netherlands +31-318-540666 New Zealand 64-9-415-2280 Norway 47-23-38-41-30 Poland 48-22-3319999 Portugal 351-21-472-7700 Russia 7-495-721-14-04 Singapore 65-6415-3170 South Africa 27-11-442-85-08 Spain 34-91-590-5200 Sweden 46-8-555-127-00 Switzerland 41-61-717-95-55 Taiwan 886-2-2578-7189 Thailand 662-651-8311 United Kingdom +44-(0)20-8328-2000
Printed on recycled paper with soy-based inks
BioPlex® 2200 System
Ordering InformationCatalog No. Description
660-0000 BioPlex® 2200System .............................................................................................................................. 1 instrument 660-0800 SampleRacks(30perbox) ................................................................................................................................. 1 box660-0801 SampleTray ......................................................................................................................................................... 1 tray660-0817 InstrumentSheathFluid(2perbox) .................................................................................................................... 1 box660-0818 InstrumentWashBuffer ....................................................................................................................................... 1 box660-2003 ReactionVessels(1000perbag) ........................................................................................................................ 1 bag666-0001 InstrumentDetectorCalibrationPack ............................................................................................................... 1 pack666-0002 InstrumentDetectorCleanPack ....................................................................................................................... 1 pack666-0003 InstrumentProbeCleaningSolutionBottles(4perbox) .................................................................................... 1 box666-0515 Sample/ReagentProbe ..................................................................................................................................... 1 each666-0578 1NNaOH ............................................................................................................................................................. 1 liter
System Specifications
Physical Dimensions
Height....................................................................... 4’-5”(1.3m)
Width........................................................................ 4’-3”(1.3m)
Depth ..................................................................... 2’-10”(0.9m)
Weight Approximately ........................................ 1032lbs.(468kg)
Performance CharacteristicsMaximumThroughput ........... 22 results per sample at 100 samples
per hour, yielding up to 2200 results per hour*TimetoFirstResult ......................20-45minutes(dependingonpanel)SampleTubes ...................................AnyCLSIprimarysampletubesSampleTray ..............................................10 racks, 5 samples eachSampleVolume .................................... 5-50µL(dependingonpanel)STATCapability .................................................. continuous accessWalk–awayCapacity .................................. 8 hours of continuous useOperationalMode ............................ Randomandcontinuousaccess,
priority(STAT)loadingOperatorInterfaces ...................................... Touchscreenmonitor,
keyboard, trackball mouseAspirationCapability ................RoboticprecisionwithclotdetectionQualityControl ............................. Levey-Jennings,WestgardRulesSampleBarCodeAcceptableSymbologies .....Code128,Codabar,
Code39,Interleaved2of5SampleTypesSerumorPlasma ........ Formoreinformation,referto
BioPlex® 2200 assay insertSampleDilutions .............1:4,1:10,and1:100(dependingonpanel)AccessDuringUse ....................... Continuoussampleinput/output,
consumables replenishment, and waste disposal without interruption of sample processing
LISConnectivity ...............................Bi-directional:ASTMStandardLaboratoryAutomationSolution(LAS) .............................AdaptableClass2LaserProduct
Power Requirements
InputVoltage ........................100-240VACat50-60Hz,1000Watt
UPS ................................................................................Provided
Water Requirements
WaterQuality ................................................ CLSITypeIIorbetter
DirectPlumbing ................................ Maximumpressureof50kPa
Installation Requirements
Crate Clearance Requirements Instrument Operational Clearance
Rear .......................5’(1.5m) Rear ...........................6”(0.2m)
Left ........................4’(1.2m) Left ............................ 3’(1.0m)
Right ......................4’(1.2m) Right ..........................6”(0.2m)
Front ....................10’(3.0m) Front .......................... 3’(1.0m)
Vertical ...................6’(1.8m) Vertical ....................... 6’(1.8m)*TypicalThroughput