32
PROGRAM SPEAKERS: SCREENS: LCD DISPLAYS: LCD MOUNT: LCD BLOCKING AND BACK BOX: PROGRAM SPEAKERS ENCLOSURES: PROGRAM SPEAKERS CUT OUTS: PROGRAM SPEAKERS GRILLE FABRIC: VIDEO WALL OPENING/STRUCTURE VIDEO WALL BLOCKING IN-WALL CAMERA MOUNT: MICROPHONES: FLOOR BOX TERMINATED (LOW VOLTAGE): AV DEVICE CUT OUTS: AV LOW VOLTAGE CABLES: POWER: AV ELECTRICAL OUTLETS & CONNECTORS: MOTOR LVC CABLE: MOTOR LVC CABLE TERMINATED: MOTOR LVC PROGRAMMED: ISDN DISTRIBUTION FOR VIDEO TELECONFERNCING: POTS 600 OHM ANALOG TELEPHONE DISTRIBUTION: STORAGE CUPBOARD: TELECOMMUNICATION CABLES: ISDN PROTOCOL: TELECOMMUNICATION CONNECTORS TERMINATED: PBX TELEPHONE/VOICE SYSTEMS: PBX TELEPHONE DISTRIBUTION: NETWORK SERVICES: TELECOMMUNICATION PLATES: HIGH SPEED DATALINKS: PLATES: COAX RF PLATES: COAX RF CABLE: CABLES: CONNECTORS: COAX RF DISTRIBUTION AMPLIFIERS: COAX RF ISOLATION TAPS AND TERMINATORS: REPEATERS & HUBS FOR DISTRIBUTION: LECTERN: CUSTOM TEACHER / STUDENT STATIONS INTERFACE: FLOOR BOX: AV ELECTRICAL CONDUITS & PULL STRINGS: MICROPHONES TERMINATED: FLOOR BOXES OR POKE THROUGH DEVICES: FLOOR BOX DIVIDERS: FLOOR BOX AC OUTLETS AND TELE/DATA PLATES: AV CONNECTORS: DIMMING EQUIPMENT: MOTOR LVC: AV INTERCONNECT WALL PLATES: DIMMING LVC FOR AV INTERFACE: DIMMING LVC PROGRAMMED: FLOOR CONCRETE POUR BOX OR FLOOR CORES: PROJECTION SCREENS: PROJECTION SCREENS LVC & SWITCH: CAMERA MOUNT: CAMERA HARDPOINTS: MICROPHONE TERMINATED: MICROPHONES: LIGHT RIGGING: PLASMA/LCD MONITORS: SPEAKER RIGGING: VIDEO PROJECTOR MOUNTS: PLASMA/LCD MONITOR ENCLOSURE: PLASMA/LCD MONITOR CEILING MOUNTS: SPEAKER HARDWARE & BACKBOX: VIDEO PROJECTOR HARD POINTS: LIGHTING SCENES AND ZONE LEVELS CONFIGURED: MICROPHONE TABLE HOLE CUTOUTS: ALL TEL/DATA CABLING AND RELATED TELECOMMUNICATIONS WORK BY EC / IT PROVIDER DATE: AV DRAWING INDEX AND RESPONSIBILITY SCHEDULE BACK BOX, CONDUIT, AND PULL STRINGS: BACK BOX, CONDUIT, AND PULL STRINGS: BACK BOX, CONDUIT, AND PULL STRINGS: AV DETAILS AV-A AUDIO VISUAL AND RELATED WORK BY OTHERS - RESPONSIBILITY SCHEDULE G.C. E.C. A.V.C. CLIENT OTHER G.C. E.C. A.V.C. CLIENT NA SUPPLIED BY INSTALLED BY CEILING MOUNTED EQUIPMENT WALL MOUNTED EQUIPMENT TABLE / LECTERN MOUNTED DEVICES ELECTRICAL (FOR AV REQUIREMENTS) LIGHTING DIMMING SYSTEMS MOTORIZED DRAPES / SHADES PERMANENT FURNISHINGS VOICE NETWORK DATA NETWORK BROADBAND VIDEO CUTOUTS, GROMMETS, PEDESTAL ACCESS PANELS, CABLE MANAGEMENT SYSTEM AND OTHER TABLE ACCESSORIES TO BE PROVIDED AND INSTALLED BY FURNITURE MANUF. TABLE MICROPHONE HOLES BY TABLE MANUFACTURER ALL LIGHTING / DIMMER SYSTEMS TO BE SPECIFIED BY LIGHTING CONSULTANT. AV EQUIPMENT CREDENZA'S WITH PROPER VENTILATION CUT OUTS AND CABLE ACCESS CUT OUTS TO BE PROVIDED AND INSTALLED BY FURNITURE MANUF. NOTES GENERAL: 1. AV DRAWINGS ARE TO BE CLEARLY COORDINATED WITH ARCHITECTURAL, ELECTRICAL, AND LIGHING PLANS. 2. GENERAL CONTRACTOR AND ELECTRICAL CONTRACTOR SHOULD REVIEW THE AV RESPONSIBILITY SCHEDULE THOROUGHLY. OTHER G.C. E.C. A.V.C. CLIENT OTHER G.C. E.C. A.V.C. CLIENT NA OTHER NOTES AVC TO PROVIDE MICROPHONE SAMPLE TO TABLE MANUFACTURER FOR HOLE SIZING AV FLOOR PLANS, REFLECTED CEILING PLANS AND CONDUIT RISERS AV SYSTEM FLOWS ARCHITECTURAL DETAILS AV DRAWING INDEX L.V.C L.V.C. NA NA L.V.C. L.V.C AV00 AV01 AV02 AV03 AV04 AV05 AV06 AV07 AV08 AV09 AV10 AV GENERAL NOTES AND LEGEND SEMINAR/LECTURE ROOM 100A - FLOOR PLAN & RCP ACTIVE LEARNING CLASSROOM 100C - FLOOR PLAN & RCP EDITING SUITE ROOM 101 - FLOOR PLAN & CONDUIT RISER RECORDING/TUTORING ROOM 104 - PLAN & CONDUIT RISER SPEAKING/WRITING LAB ROOM 106 - FLOOR PLAN & CONDUIT RISER SCREENING/LECTURE ROOM 103 - FLOOR PLAN & RCP SCREENING/LECTURE ROOM 103 - ELEVATIONS & CONDUIT RISER COLLABORATE / EDIT SUITES 108 & 110 - FLOOR PLAN & CONDUIT RISER READING ROOM 112 - FLOOR PLAN RCP ELEVATION CONDUIT RISER AV11 ENTRANCE VIDEO WALL PLAN AND ELEVATION AV00.1 1ST FLOOR OVERALL PLAN AV DETAILS AV-B READING ROOM + ENTRANCE VIDEO WALL CONDUIT RISER AV03.1 AV12 AV-C AV DETAILS SEMINAR 100A AND ACTIVE LEARNING 100C CONDUIT RISER AV BID SET SEMINAR ROOM 100A AV SIGNAL FLOW AV100 ACTIVE LEARNING CLASSROOM 100C AV SIGNAL FLOW AV101 ROOM 100A/100C CONTROL FLOW AV101.1 EDITING SUITE 101 AV SIGNAL FLOW AV102 SCREENING ROOM 103 AV SIGNAL FLOW #1 (TEACHING STATION) AV103 SCREENING ROOM 103 AV SIGNAL FLOW #2 (AV RACK) AV103.1 SCREENING ROOM 103 CONTROL FLOW AV103.2 RECORDING/TUTORING ROOM 104 AV SIGNAL FLOW AV104 SPEAKING/WRITING LAB 106 AV SIGNAL FLOW AV105 COLLABORATE/EDIT 1 ROOM 108 AV SIGNAL FLOW AV106 COLLABORATE/EDIT 2 ROOM 110 AV SIGNAL FLOW AV107 LIVING ROOM 112 SIGNAL FLOW AV108 ENTRANCE DIGITAL SIGNAGE AV109 AV-D AV DETAILS THIS INCLUDES CHIEF PAC501 MOUNTS SPECIFIED FOR ROOM 100C AND 112 DATE: FILE: DATE NO BY DESCRIPTION C COPYRIGHT 2012 DURKEE BROWN VIVEIROS WERENFELS ARCHITECTS UNAUTHORIZED USE IS PROHIBITED. JOB NO.: DRAWN BY: AV BID SET 12.16.15 1129 Harrington School of Communication & Media University of Rhode Island Kingston, RI MBH AV RESPONSIBILITIES SCHEDULE AND GENERAL NOTES AV00 ACT Associates, LLC 922F Stafford Road Storrs, CT 06268 tel. 860.429.5938 www.act-associates.com THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

AV00 - Rhode Island

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AV00 - Rhode Island

PROGRAM SPEAKERS:

SCREENS:

LCD DISPLAYS:

LCD MOUNT:

LCD BLOCKING AND BACK BOX:

PROGRAM SPEAKERS ENCLOSURES:

PROGRAM SPEAKERS CUT OUTS:

PROGRAM SPEAKERS GRILLE FABRIC:

VIDEO WALL OPENING/STRUCTURE

VIDEO WALL BLOCKING

IN-WALL CAMERA MOUNT:

MICROPHONES:

FLOOR BOX TERMINATED (LOW VOLTAGE):

AV DEVICE CUT OUTS:

AV LOW VOLTAGE CABLES:

POWER:

AV ELECTRICAL OUTLETS & CONNECTORS:

MOTOR LVC CABLE:

MOTOR LVC CABLE TERMINATED:

MOTOR LVC PROGRAMMED:

ISDN DISTRIBUTION FOR VIDEO TELECONFERNCING:

POTS 600 OHM ANALOG TELEPHONE DISTRIBUTION:

STORAGE CUPBOARD:

TELECOMMUNICATION CABLES:

ISDN PROTOCOL:

TELECOMMUNICATION CONNECTORS TERMINATED:

PBX TELEPHONE/VOICE SYSTEMS:

PBX TELEPHONE DISTRIBUTION:

NETWORK SERVICES:

TELECOMMUNICATION PLATES:

HIGH SPEED DATALINKS:

PLATES:

COAX RF PLATES:

COAX RF CABLE:

CABLES:

CONNECTORS:

COAX RF DISTRIBUTION AMPLIFIERS:

COAX RF ISOLATION TAPS AND TERMINATORS:

REPEATERS & HUBS FOR DISTRIBUTION:

LECTERN:

CUSTOM TEACHER / STUDENT STATIONS

INTERFACE:

FLOOR BOX:

AV ELECTRICAL CONDUITS & PULL STRINGS:

MICROPHONES TERMINATED:

FLOOR BOXES OR POKE THROUGH DEVICES:

FLOOR BOX DIVIDERS:

FLOOR BOX AC OUTLETS AND TELE/DATA PLATES:

AV CONNECTORS:

DIMMING EQUIPMENT:

MOTOR LVC:

AV INTERCONNECT WALL PLATES:

DIMMING LVC FOR AV INTERFACE:

DIMMING LVC PROGRAMMED:

FLOOR CONCRETE POUR BOX OR FLOOR CORES:

PROJECTION SCREENS:

PROJECTION SCREENS LVC & SWITCH:

CAMERA MOUNT:

CAMERA HARDPOINTS:

MICROPHONE TERMINATED:

MICROPHONES:

LIGHT RIGGING:

PLASMA/LCD MONITORS:

SPEAKER RIGGING:

VIDEO PROJECTOR MOUNTS:

PLASMA/LCD MONITOR ENCLOSURE:

PLASMA/LCD MONITOR CEILING MOUNTS:

SPEAKER HARDWARE & BACKBOX:

VIDEO PROJECTOR HARD POINTS:

LIGHTING SCENES AND ZONE LEVELS CONFIGURED:

MICROPHONE TABLE HOLE CUTOUTS:

ALL TEL/DATA CABLING AND RELATED TELECOMMUNICATIONS WORK BY EC / IT PROVIDER

DATE:

AV DRAWING INDEX AND RESPONSIBILITY SCHEDULE

BACK BOX, CONDUIT, AND PULL STRINGS:

BACK BOX, CONDUIT, AND PULL STRINGS:

BACK BOX, CONDUIT, AND PULL STRINGS:

AV DETAILS

AV-A

AUDIO VISUAL AND RELATED WORK BY OTHERS - RESPONSIBILITY SCHEDULE

G.C. E.C. A.V.C. CLIENT OTHER G.C. E.C. A.V.C. CLIENT NA

SUPPLIED BY INSTALLED BY

CEILING MOUNTED EQUIPMENT

WALL MOUNTED EQUIPMENT

TABLE / LECTERN MOUNTED DEVICES

ELECTRICAL (FOR AV REQUIREMENTS)

LIGHTING DIMMING SYSTEMS

MOTORIZED DRAPES / SHADES

PERMANENT FURNISHINGS

VOICE NETWORK

DATA NETWORK

BROADBAND VIDEO

CUTOUTS, GROMMETS, PEDESTAL ACCESS PANELS, CABLE MANAGEMENT SYSTEM AND

OTHER TABLE ACCESSORIES TO BE PROVIDED AND INSTALLED BY FURNITURE MANUF.

TABLE MICROPHONE HOLES BY TABLE MANUFACTURER

ALL LIGHTING / DIMMER SYSTEMS TO BE SPECIFIED BY LIGHTING CONSULTANT.

AV EQUIPMENT CREDENZA'S WITH PROPER VENTILATION CUT OUTS AND CABLE ACCESS

CUT OUTS TO BE PROVIDED AND INSTALLED BY FURNITURE MANUF.

NOTES

GENERAL:

1. AV DRAWINGS ARE TO BE CLEARLY COORDINATED

WITH ARCHITECTURAL, ELECTRICAL, AND LIGHING

PLANS.

2. GENERAL CONTRACTOR AND ELECTRICAL

CONTRACTOR SHOULD REVIEW THE AV

RESPONSIBILITY SCHEDULE THOROUGHLY.

OTHER

G.C. E.C. A.V.C. CLIENT OTHER G.C. E.C. A.V.C. CLIENT NAOTHER

NOTES

AVC TO PROVIDE MICROPHONE SAMPLE TO TABLE MANUFACTURER FOR HOLE SIZING

AV FLOOR PLANS, REFLECTED CEILING PLANS AND CONDUIT RISERS

AV SYSTEM FLOWS

ARCHITECTURAL DETAILS

AV DRAWING INDEX

L.V.C

L.V.C.

NA

NA L.V.C.

L.V.C

AV00

AV01

AV02

AV03

AV04

AV05

AV06

AV07

AV08

AV09

AV10

AV GENERAL NOTES AND LEGEND

SEMINAR/LECTURE ROOM 100A - FLOOR PLAN & RCP

ACTIVE LEARNING CLASSROOM 100C - FLOOR PLAN & RCP

EDITING SUITE ROOM 101 - FLOOR PLAN & CONDUIT RISER

RECORDING/TUTORING ROOM 104 - PLAN & CONDUIT RISER

SPEAKING/WRITING LAB ROOM 106 - FLOOR PLAN & CONDUIT RISER

SCREENING/LECTURE ROOM 103 - FLOOR PLAN & RCP

SCREENING/LECTURE ROOM 103 - ELEVATIONS & CONDUIT RISER

COLLABORATE / EDIT SUITES 108 & 110 - FLOOR PLAN & CONDUIT RISER

READING ROOM 112 - FLOOR PLAN RCP ELEVATION CONDUIT RISER

AV11 ENTRANCE VIDEO WALL PLAN AND ELEVATION

AV00.1

1ST FLOOR OVERALL PLAN

AV DETAILS

AV-B

READING ROOM + ENTRANCE VIDEO WALL CONDUIT RISER

AV03.1

AV12

AV-CAV DETAILS

SEMINAR 100A AND ACTIVE LEARNING 100C CONDUIT RISER

AV

B

ID

S

ET

SEMINAR ROOM 100A AV SIGNAL FLOWAV100

ACTIVE LEARNING CLASSROOM 100C AV SIGNAL FLOWAV101

ROOM 100A/100C CONTROL FLOWAV101.1

EDITING SUITE 101 AV SIGNAL FLOWAV102

SCREENING ROOM 103 AV SIGNAL FLOW #1 (TEACHING STATION)AV103

SCREENING ROOM 103 AV SIGNAL FLOW #2 (AV RACK)AV103.1

SCREENING ROOM 103 CONTROL FLOWAV103.2

RECORDING/TUTORING ROOM 104 AV SIGNAL FLOWAV104

SPEAKING/WRITING LAB 106 AV SIGNAL FLOWAV105

COLLABORATE/EDIT 1 ROOM 108 AV SIGNAL FLOWAV106

COLLABORATE/EDIT 2 ROOM 110 AV SIGNAL FLOWAV107

LIVING ROOM 112 SIGNAL FLOWAV108

ENTRANCE DIGITAL SIGNAGEAV109

AV-DAV DETAILS

THIS INCLUDES CHIEF PAC501 MOUNTS SPECIFIED FOR ROOM 100C AND 112

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

AV RESPONSIBILITIESSCHEDULE AND

GENERAL NOTES

AV00

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

Page 2: AV00 - Rhode Island

CATV

IPTV

POTS

1

S

M

CABLE TYPES

CODE: CABLE FUNCTION: TYPE: MANF. & CAT. #: O.D.: AREA:

3G-SDI 3G-SDI CABLE (PLENUM) RG-11/U BELDEN 7731A 0.400 0.1257

A/M AUDIO/MICROPHONE (PLENUM) 2COND/20AWG/SH/PL WESTPENN 25292B 0.138 0.0150

AXLINK AXLINK (PLENUM) 2C 22AWG SH/2C 18AWG/PL BELDEN 1502P 0.205 0.0330

CAT CAT-5e (PLENUM) 4TW. PR. /24AWG/SH/PL BELDEN 1533P 0.190 0.0284

CAT-6 CAT-6a (PLENUM) 4TW. PR. /23AWG/PL BELDEN 3613 0.237 0.0441

CATV CABLE TO (PLENUM) DROP RG-6U CATV PLENUM BELDEN 9116P 0.235 0.0434

CRESNET CRESNET (PLENUM) 2C 22AWG SH/2C 18AWG/PL BELDEN 1502P 0.205 0.0330

C REMOTE CONTROL DATA BUS (PLENUM) 2TW.PR./18GA/SH/PL WESTPENN 25440B 0.253 0.0503

DISPLAYPORT PLENUM HDMI WITH DISPLAYPORT ADAPTER 15C/24AWG/SH/PL ATLONA ATP-14029 0.354 0.0984

DM-8G DIGITALMEDIA 8G CABLE (PLENUM) 4TW.PR.24GA/SH/PL CRESTRON DM-CBL-8G-P 0.244 0.0468

DM-CAT DIGITALMEDIA CABLE (PLENUM) 4TW.PR/1TW.PR./4TW.PR/SH/PL CRESTRON DM-CBL-P 0.580 0.2642

DTP DIGITAL AND SKEW-FREE CABLE (PLENUM) 8COND/26AWG/SH/PL EXTRON 22-215-03 0.235 0.0434

DVI DVI VIDEO CABLE (PLENUM) 15C/24AWG/SH/PL ATLONA ATP-14009 0.354 0.0984

FIBER DUPLEX MULTIMODE FIBER CABLE (PLENUM) (2) 62.5 MICRON CORNING 002K88-31130-A3 0.480 0.1810

FIBER-50UM DUPLEX MULTIMODE FIBER CABLE (PLENUM) (2) 50 MICRON CORNING 002T88-31191-A3 0.480 0.1810

FO-SM DUPLEX SINGLEMODE FIBER CABLE (PLENUM) (2) 8.2 MICRON CORNING 002E88-31131-A3 0.510 0.2043

HD-SDI HD-SDI CABLE (PLENUM) RG-11/U BELDEN 7731A 0.400 0.1257

HDMI HDMI A/V CABLE (PLENUM) 15C/24AWG/SH/PL ATLONA ATP-14029 0.354 0.0984

MIC MICROPHONE CABLE (PLENUM) 2COND/20AWG/SH/PL WESTPENN 25292B 0.138 0.0150

MUTE MICROPHONE MUTE CONTROL (PLENUM) 4COND/22AWG/SH/PL BELDEN 6502FC 0.133 0.0139

P CABLE FOR POWER (PLENUM) 2 COND/18GA/PL WESTPENN 25224B 0.150 0.0177

RG-8 PLENUM COAX RG-8/U CATV PLENUM BELDEN 7733A 0.355 0.0990

RG-11 CATV BACKBONE PLENUM RG-11 CATV PLENUM BELDEN 1523AP 0.260 0.0531

R RED/GREEN/BLUE/H-SYNC/V-SYNC (PLENUM) 5-RG-59U/PL EXTRON 22-103-02 0.304 0.0726

SC 70V CEILING SPEAKERS (PLENUM) 2 COND/18GA/PL WESTPENN 25224B 0.150 0.0177

SDI SDI CABLE (PLENUM) RG-11/U BELDEN 7731A 0.400 0.1257

SF SKEW FREE UTP (PLENUM) 4TW. PR. 23 AWG EXTRON 22-142-03 0.240 0.0452

S PROGRAM 8 OHM SPEAKERS (PLENUM) 2 COND/14GA/PL WESTPENN 25226B 0.260 0.0531

UHF WIRELESS MIC ANTENNA (PLENUM) 50Ω RG-58U/PL BELDEN 88240 0.160 0.0201

V DIGITAL VIDEO CABLE (PLENUM) 75Ω PREC. VID/PL BELDEN 1506A 0.200 0.0314

YC S-VIDEO (PLENUM) (2) 75Ω COAX 26 GA/PL EXTRON 22-129-03 0.250 0.0491

1

1

WP

GENERAL:

1. AV DRAWINGS, COMMUNICATIONS DRAWINGS, POWER PLAN DRAWINGS AND ARCHITECTURAL DRAWINGS SHOULD BE CAREFULLY REVIEWED

SIMULTANEOUSLY TO AVOID UNDER-COUNTING OR OVER-COUNTING DEVICES.

2. QUANTITIES GIVEN ON AV DETAIL PAGES AND AV ROOM DRAWINGS MUST BE CONFIRMED BY EACH DISCIPLINE WHEN REVIEWING THE AV DRAWINGS. THE

QUANTITIES GIVEN ARE PRELIMINARY AND MAY NOT REFLECT ALL LAST MINUTE CHANGES. ANY DISCREPANCIES SHOULD BE REVIEWED WITH THE OWNER

.

3. ALL SPARE/FUTURE CONDUITS ARE TO HAVE PULL STRINGS. ENSURE PULL STRINGS ARE TIED OFF AT BOTH ENDS OF THE CONDUIT RUN.

4. FINAL LOCATION AND COORDINATION OF ALL FLOOR BOXES TO BE VERIFIED IN FIELD WITH ARCHITECT PRIOR TO INSTALLATION.

5. ALL TELE/DATA, NETWORK, AND 120V AC SERVICES INDICATED ON AV DRAWINGS ARE FOR AV USE ONLY. FOR ALL OTHER REQUIREMENTS REFER TO

COMMUNICATIONS AND POWER PLANS.

6. CEILING MOUNTED PROJECTORS NEED TO BE ISOLATED FROM BUILDING STRUCTURES OR MECHANICAL DEVICES THAT MAY INDUCE VIBRATION TO VIDEO

PROJECTORS.

ACOUSTICAL:

1. AN OVERALL DESIGN GOAL FOR AN NC-25 TO NC-30 NOISE CRITERIA RATING IS DESIRABLE.

2. AMBIENT NOISE FROM ALL IN-ROOM AND EXTERNAL NOISE SOURCES NOT TO EXCEED 40dB A-WEIGHTED.

3. TO PREVENT SOUND LEAKAGE INTO THESE ROOMS FROM ADJOINING SPACES, ALL WALLS SHOULD EXTEND TO THE DECKING ABOVE. ALL PENETRATIONS

LEAVING THE SPACE SHOULD BE SEALED AS REQUIRED. THE SPACE ABOVE THE CEILING TILES MAY ALSO NEED CONSIDERATION AND TREATING WITH

FIBERGLASS BATTING.

4. MINIMUM SOUND TRANSMISSION CLASS FOR WALL CONSTRUCTION TO BE OF AN STC-45 RATING. DOORS INTO THE SPACE TO HAVE A MINIMUM RATING OF

STC-40 TO STC-55. WALL PARTITIONS (WHERE APPLICABLE) TO HAVE A MINIMUM RATING OF STC-55 TO STC-65.

5. ACOUSTICAL REFLECTIONS OFF ALL GLASS SURFACES SHOULD BE ADDRESSED WITH APPROPRIATE WINDOW TREATMENTS.

6. MAXIMUM REVERBERATION TIME SHOULD NOT EXCEED .6 SECONDS.

7. MECHANICAL DEVICES SUCH AS HEAT EXCHANGERS AND VENTILATION UNITS SHOULD NOT BE LOCATED IN THE CEILING ABOVE THE IMMEDIATE SPACE OR

THE SURROUNDING AREAS.

8. AIR VELOCITY AT SUPPLY REGISTER NOT TO EXCEED 425 FEET PER MINUTE. AIR VELOCITY AT RETURN GRILLE NOT TO EXCEED 510 FEET PER MINUTE.

FURNISHINGS:

1. ALL TABLES AND CREDENZAS TO BE PROVIDED WITH INTEGRATED POWER AND CABLE MANAGEMENT.

2. CHOOSE FURNITURE WITHOUT GLOSSY TOPS OR STRONG COLORS. THE BEST TABLE TOP SURFACE IS A FLAT SATIN FINISH.

3. COORDINATE ALL FLOOR BOX OR FLOOR CORING LOCATION WITH TABLE MANUFACTURER AND ARCHITECT.

4. EQUIPMENT RACKS IN A CREDENZA NEED A MINIMUM DEPTH OF 26"

5. EQUIPMENT RACKS IN A CREDENZA NEED A MINIMUM OF 40" OF ROOM FOR TWO SIDE BY SIDE RACKS IN ONE COMPARTMENT WITH A CUT OUT TO THE

NEXT COMPARTMENT FOR CABLE MANAGEMENT TO A THIRD RACK, IF NECESSARY.

6. CREDENZA EQUIPMENT RACKS WILL REQUIRE VENTILATION FROM THE FRONT TOE KICK TO THE REAR TOP BACK.

LIGHTING:

1. LIGHTING FIXTURES TO BE SELECTED WITH ELECTRONIC DIMMING BALLASTS AND TO BE CIRCUITED IN ZONES THAT ALLOW FOR ANY DISPLAYS TO BE

PROTECTED FROM AMBIENT LIGHT WHEN DESIRABLE.

2. LIGHTING FIXTURES SHOULD BE SELECTED FOR CONTROL AND DIRECTIONALITY, ALLOWING THE TABLE TO BE PROPERLY AND EVENLY LIT, WITHOUT

AFFECTING THE DISPLAY'S CONTRAST LEVELS. 85% DIFFUSED, 15% DIRECTIONAL.

3. RS-232 LIGHTING INTERFACE TO BE PROVIDED BY OTHERS TO ALLOW THE AV CONTROL SYSTEM TO SELECT LIGHTING PRESET SCENES.

4. ON/OFF ENTRY MODULES SHOULD BE PROVIDED AT DOORWAY ENTRANCES.

5. PENDANT LIGHTING SHOULD BE AVOIDED AS IT MAY CONFLICT WITH THE IMAGE CONE OF THE CEILING MOUNTED PROJECTOR (WHERE APPLICABLE).

6. DRAPES/SHADES TO BE PROVIDED WITH RS-232 INTERFACE FOR CONTROL FROM AV SYSTEM. LIMITS FOR DRAPES/SHADES TO BE SET BY OTHERS.

ELECTRICAL:

1. ALL AUDIO AND VIDEO AC OUTLETS SHOULD HAVE ITS OWN DEDICATED PHASE, NEUTRAL AND ISOLATED GROUND CONDUCTORS HOME RUN TO THE

PANEL FROM WHICH IT IS FED.

2. 120V AC SERVICES FOR EQUIPMENT RACKS AND VIDEO PROJECTORS TO SHARE THE SAME PHASE.

3. COORDINATE FINAL LOCATIONS OF SWITCHES, AV-PLATES AND J-BOXES WITH WALL TREATMENT AND SURFACES.

GENERAL:

1. THESE NOTES APPLY TO ALL SPACES WITH VIDEO-CONFERENCING CAPABILITIES DAY ONE AND THOSE WITH FUTURE VIDEO-CONFERENCING CAPABILITIES.

FURNISHINGS:

1. TABLES IN MEDIUM TO LARGE VIDEO-CONFERENCING SPACES SHOULD ACCOMMODATE AN OPEN VIEW OF ALL PARTICIPANTS WITHOUT NEEDING TO LEAN

OVER THE TABLE. TRIANGLE OR TRAPEZOIDAL SHAPES ARE IDEAL.

2. WHITE OR VERY LIGHT FURNITURE WILL REFLECT TOO MUCH LIGHT UPWARD INTO PEOPLES FACES. HIGHLY REFLECTIVE FURNITURE WILL REFLECT

GLARE FROM THE CEILING FIXTURES INTO PEOPLES FACES. FOR BEST RESULT USE FURNITURE WITH MEDIUM TONES, GRAY TAN OR WOOD TABLES WORK

WELL WITH A MATTE FINISH.

3. CHAIRS SHOULD NOT ROCK OR ROLL, TO AVOID DISTRACTIONS DURING A VIDEO-CONFERENCE.

4. WALL COLOR WITHIN THE FIELD OF VIEW OF THE CAMERA HAS A SIGNIFICANT IMPACT ON FAR-END PERCEPTION OF VIDEO QUALITY. LIGHT GRAY TO BLUE

COLORS WORK BEST. AVOID LARGE EXPANSES OF WHITE. THIS ALSO APPLIES TO ANY DRAPES/SHADES IN THE CAMERAS VIEW

4.1. RECOMMENDED COLORS: LILAC, GRAY, BLUE/GRAY, LIGHT BLUE, LIGHT BLUE/LILAC

LIGHTING:

1. LIGHTING SHOULD MEASURE 35-40 FOOT CANDLES AT A 4 FOOT VERTICAL PLANE AT THE TABLE WITH A COLOR TEMPERATURE OF 3500 KELVIN.

2. MAIN LIGHTS OR "KEY" LIGHTING SHOULD BE CAST AT ABOUT A 45° ANGLE TO THE PARTICIPANTS, RESULTING IN SHADOWS THAT DEFINE FACIAL

FEATURES.

3. LIGHTING IN THESE SPACES SHOULD HAVE A HIGHER LEVEL OF CONTROL TO MAXIMIZE THE LIGHTING SCENES FOR VIDEO- CONFERENCING.

4. BACKGROUND LIGHTING SHOULD BE UNIFORM AND AVOID DARK SPOTS AND BRIGHT AREAS TO AVOID LIGHT DISTORTION ON PEOPLES FACES. WALL

WASHER LUMINARIES ARE RECOMMENDED FOR BACK AND SIDE WALLS.

5. STANDARD FLUORESCENT FIXTURES, WALL SCONCES AND OTHER BRIGHT LIGHT SOURCES THROW A GREAT DEAL OF GLARE AT THE CAMERA, CAUSING

THE CEILING TO REGISTER AS A BIG WHITE SPOT.

6. WINDOWS SHOULD ALWAYS BE SHADED DURING VIDEO-CONFERENCE, PREFERABLY WITH BLACKOUT SHADES TO AVOID PROBLEMS WITH ROOM LIGHTING

RATIOS.

AV FLOOR PLAN SYMBOLS

SYMBOLS DESCTIPTION

WALL MOUNTED AC

DUPLEX OUTLET

WALL MOUNTED AC

QUAD DUPLEX OUTLET

WALL MOUNTED CATV DROP

WALL MOUNTED IPTV DROP

WALL MOUNTED POTS DROP

WALL MOUNTED LAN DROP

TABLE MICROPHONE

GENERIC TABLE BOX

WALL MOUNTED JUNCTION

BOX

WALL MOUNTED EQUIPMENT RACK

JUNCTION BOX OR AV PLATE

FLUSH MOUNTED FLOOR BOX

FLUSH MOUNTED FLOORCORE

SYMBOLS DESCTIPTION

CEILING MOUNTED

SPEAKER

GENERIC PROJECTOR

SYMBOL

GENERIC PROJECTION

SCREEN SYMBOL

CEILING MOUNTED

JUNCTION BOX

CEILING MOUNTED POWER

CEILING MOUNTED LAN

DROP

CEILING MOUNTED

MICROPHONE

CEILING MOUNTED JUNCTION

BOX WITH POWER/LAN

AV LEGEND

CABLE LEGEND

STANDARD ABBREVIATIONSGENERAL NOTES

VIDEO CONFERENCING NOTES

AV REFLECTED CEILING PLAN

SYMBOLS

AV CONDUIT RISER SYMBOLS

AV

ABF

AFC

AFF

ASC

ACFL

AP

ACT

ADD

ALT

AC

ANSI

APX

AUTO

BEL

BS

BOT

BTU

CB

CLG

CM

COL

CATV

C

CONF

CONST

CONT

CONTR

D

dB

DP

DTL

DIAG

DIAM

AV INTERFACE

ABOVE

ABOVE FINISH CEILING

ABOVE FINISH FLOOR

ABOVE SUSPENDED CEILING

ACCESS FLOOR

ACCESS PANEL

ACOUSTICAL TILE

ADDENDUM

ALTERNATE

ALTERNATING CURRENT

AMERICAN NATIONAL

STANDARD INSTITUTE

APPROXIMATE

AUTOMATIC

BELOW

BOTH SIDES

BOTTOM

BRITISH THERMAL UNITS

CEILING JUNCTION BOX

CEILING

CENTIMETER

COLUMN

COMMUNITY ANTENNA TV

CONDUIT

CONFERENCE

CONSTRUCTION

CONTINUOUS

CONTRACTOR

DATA

DECIBEL

DEPTH

DETAIL

DIAGONAL

DIAMETER

LAN

LC

LVC

M

MANUF

MAX

MECH

MWK

MIN

MISC

MD

MULL

NTSC

NR

NIC

NTS

OFE

OPG

OH

PED

POTS

PROJ

RF

REF

REM

REV

R

RM

RO

SCH

SEC

SIM

LOCAL AREA NETWORK

LIGHT CONTROL

LOW VOLTAGE CONTROL

METER (S)

MANUFACTURER

MAXIMUM

MECHANICAL

MILLWORK

MINIMUM

MISCELLANEOUS

MOUNTING DISTANCE

MULLION

NATIONAL TV SYSTEM

COMMITTEE

NOISE REDUCTION

NOT IN CONTRACT

NOT TO SCALE

OWNER FURNISHED

EQUIPMENT

OPENING

OVERHEAD

PEDESTAL

PLAIN OLD TELEPHONE

SERVICE

PROJECTOR

RADIO FREQUENCY

REFERENCE

REMOVE

REVISION

RIGHT

ROOM

ROUGH OPENING

SCHEDULE

SECTION

SIMILAR

DIM

DC

DR

DWG

ELEC

EC

EL

ENC

EQ

EQUIP

EXG

FO

FLR

FB

FC

FP

FUT

GA

GC

HVAC

HD

H

HDTV

HOR

INCL

IPTV

IR

ISDN

INT

JST

J

KO

LBL

L

DIMENSION

DIRECT CURRENT

DOOR

DRAWING

ELECTRICAL

ELECTRICAL CONTRACTOR

ELEVATION

ENCLOSURE

EQUAL

EQUIPMENT

EXISTING

FINISH OPENING

FLOOR

FLOOR BOX

FLOOR CORE

FRONT PROJECTION

FUTURE

GAGE, GAUGE

GENERAL CONTRACTOR

HEATING/COOLING

HEAVY-DUTY

HEIGHT

HIGH-DEFINITION TELEVISION

HORIZONTAL

INCLUDED

INTERNET PROTOCOL TELEVISION

INFRARED

INTEGRATED SERVICES

DIGITAL NETWORK

INTERIOR

JOIST

JUNCTION BOX

KNOCKOUT

LABEL

LEFT

SP

SPK

SPEC

STD

S-VHS

SVGA

SUS

SW

SYS

TEL/COM

TEL

TV

TD

TYP

UON

VERT

VGA

VTC

V ac

V dc

WH

W

W/O

SOUNDPROOF

SPEAKER

SPECIFICATION

STANDARD

SUPER VHS (VIDEO FORMAT)

SUPER VIDEO GRAPHIC ADAPTER

SUSPENDED

SWITCH

SYSTEM

TELECOMMUNICATIONS

TELEPHONE

TELEVISION

THROW DISTANCE

TYPICAL

UNLESS OTHERWISE NOTED

VERTICAL

VIDEO GRAPHIC ADAPTER

VIDEO TELECONFERENCING

VOLTS ALTERNATING CURRENT

VOLTS DIRECT CURRENT

WALL HUNG

WIDTH

WITHOUT

CEILING MOUNTED POWER

OUTLET - 120V AC

AC CLOCK

RECEPTACLE - 120V AC

AC DUPLEX OUTLET - 12V AC

LAN WITH QUANTITY

ANALOG LINE WITH

QUANITY

WALL PHONE

CATV

J-BOX

SYMBOLS DESCTIPTION

STUBBED CONDUIT

RIGID CONDUIT

PLENUM CABLE

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

AV GENERAL NOTESAND LEGEND

AV00.1

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 3: AV00 - Rhode Island

1

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

1ST FLOOR OVERALLPLAN

AV01

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 3/16" = 1'-0"

FIRST FLOOR OVERALL PLAN

1

60" x 96"

SC

RE

EN

48" LCD

4

8

"

L

C

D

48" LCD

48" L

CD

60" x 96"

SC

RE

EN

48" L

CD

48" LCD

48" LCD

90" LCD

76.25" x 122"

SC

RE

EN

48" LCD

4

8

"

L

C

D

4

8

"

L

C

D

48" L

CD

48" L

CD

48" L

CD

QUAD 46" LCD VIDEO WALL

J-5

2 GANG AV INPUT PLATE

WITH POWER AND LAN

LOCATED AT 15" AFF

AV10AV09AV06AV05

AV02

AV11

AV04 AV07

AV03

Page 4: AV00 - Rhode Island

CA

TV

1

SS

S S

S

S

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SEMINAR LECTUREROOM 100A - FLOOR

PLAN & RCP

AV02

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 3/8" = 1'-0"

SEMINAR/LECTURE ROOM 100A FLOOR PLAN

1

Scale: 3/8" = 1'-0"

SEMINAR/LECTURE ROOM 100A RCP

2

AV-1A

AV INPUT PLATE WITH POWER AND LAN

OFE LECTERN

FB-1A

FLOORBOX WITH

POWER, LAN, AND AV

CONNECTIVITY

(FUTURE)

AV-2A

AV INPUT PLATE WITH

POWER AND LAN

(FUTURE)

FB-2A

FLOORBOX WITH

POWER, LAN, AND AV

CONNECTIVITY

J-1

MAIN PULL BOX WITH (2)

QUAD POWER, (4) LAN,

AND (2) CATV

D-1

AV-A

MIDDLE ATLANTIC MRK-24-26

AV EQUIPMENT RACK

D-4

AV-A

TANNOY CVS6 CEILING

SPEAKERS

TYP. 6

CB-1A

WITH POWER

AND LAN

D-2

AV-A

EPSON G6470WU 4500

LUMEN PROJECTOR

D-3

AV-A

DALITE TENSIONED

ADVANTAGE ELECTROL

60"H x 96"W CEILING

RECESSED ELECTRIC

PROJECTION SCREEN

J-2A

SCREEN SWITCH

TO J-1

13' THROW DISTANCE

FURNITURE NOTES:

1. RECONFIGURABLE FURNITURE SYSTEM WILL UTILIZE FLOOR BOXES SUPPLIED WITH

POWER/LAN BY OTHERS.

2. MOVABLE LECTERN WILL UTILIZE FLOOR BOXES SUPPLIED WITH POWER BY EC AND LAN BY

TEL/DATA.

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

2. MECHANICAL DEVICES LOCATED WITHIN CEILING SHOULD NOT BE LOCATED NEAR CEILING

PROJECTORS. THESE DEVICES COULD INDUCE VIBRATION AT THE PROJECTORS. TAKE

PRECAUTION TO LIMIT ANY VIBRATION WITHIN THE CEILING THAT COULD BE TRANSFERRED TO

THE PROJECTORS.

LIGHTING / DRAPE NOTES:

1. PENDANT LIGHT FIXTURES TO BE CAREFULLY COORDINATED SO THAT THEY DO NOT IMPEDE

DATA PROJECTORS CONE.

2. LIGHTING ZONES TO BE CIRCUITED AND DIMMABLE. FRONT ZONE OF LIGHTING CLOSEST TO

PROJECTION SCREENS SHOULD BE ON A SEPARATE ZONE SO THAT IT CAN BE DIMMED OR

SHUT OFF IF NECESSARY.

3. WINDOW TREATMENTS SHOULD BE PROVIDED WHERE AMBIENT LIGHT FROM OUTDOORS OR

OTHER LIGHT SOURCES THAT HAVE THE POTENTIAL TO AFFECT THE PROJECTED IMAGES ON

THE PROJECTION SCREENS.

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

PROJECTOR 311 1 1061 1061

EQUIPMENT RACK 1500 1 5115 5115

TOTAL BTU: 6176 6176

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

D-19

AV-D

MIDDLE ATLANTIC SRSR

RACK INSIDE LECTERN

D-17

AV-C

EXTRON CABLE CUBBY 500

Page 5: AV00 - Rhode Island

1

1

CA

TV

S S

S S

S S

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012

DURKEE BROWN VIVEIROS WERENFELS ARCHITECTS

UNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of

Communication & Media

University of Rhode IslandKingston, RI

MBH

ACTIVE LEARNING

CLASSROOM 100C -

FLOOR PLAN & RCP

AV03

ACT Associates, LLC

922F Stafford Road

Storrs, CT 06268

tel. 860.429.5938

www.act-associates.com

Scale: 3/8" = 1'-0"

ACTIVE LEARNING CLASSROOM 100C FLOOR PLAN1

FB-2C

FLOORBOX WITH POWER,

LAN AND LOCAL AV

CONNECTIVITY TO MONITOR

D-5

AV-A

48" LED MONITOR ON

CHIEF CHEIF

PNRIW+PAC-501

PULL-OUT MOUNT

TYP. 3 LOCATIONS

Scale: 3/8" = 1'-0"

ACTIVE LEARNING CLASSROOM 100C FLOOR PLAN2

FB-3C

FLOORBOX WITH POWER,

LAN AND LOCAL AV

CONNECTIVITY TO

MONITOR

FB-1C

FLOORBOX WITH

POWER, LAN AND AV

CONNECTIVITY

FB-4C

FLOORBOX WITH POWER,

LAN AND LOCAL AV

CONNECTIVITY TO

MONITOR

FB-5C

FLOORBOX WITH POWER,

LAN AND LOCAL AV

CONNECTIVITY TO

MONITOR

J-5C

WITH POWER AND LAN

J-2C

WITH POWER AND LAN

J-3C

WITH POWER AND LAN

J-4C

WITH POWER AND LAN

D-5

AV-A

48" LED MONITOR ON

CHIEF CHEIF

PNRIW+PAC-501

PULL-OUT MOUNT

TYP. 3 LOCATIONS

D-6

AV-A

48" LED MONITOR ON

CHIEF MTMU MOUNT

TYP. 1 LOCATIONS

D-5

AV-A

48" LED MONITOR

RECESSED ON CHIEF

CHEIF PNRIW+PAC-501

MOUNT

TYP. 3 LOCATIONS

D-4

AV-A

TANNOY CVS6 CEILING

SPEAKERS

TYP. 6

CB-1C

WITH POWER AND LAN

D-2

AV-A

EPSON G6470 4500 LUMEN

PROJECTOR

D-3

AV-A

DALITE TENSIONED

ADVANTAGE ELECTROL

60"H x 96"W CEILING

RECESSED ELECTRIC

PROJECTION SCREEN

NOTE: TABLES WILL HAVE (8)

BUILT IN LAPTOP "GARAGES".

PROVIDE NECESSARY NETWORK

CONNECTIVITY PER URI

STANDARDS (BY OTHERS).

J-6C

SCREEN SWITCH

13' THROW DISTANCE

FURNITURE NOTES:

1. TABLE PEDESTALS SHOULD HAVE REMOVABLE ACCESS PANEL FOR SERVICE.

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

2. MECHANICAL DEVICES LOCATED WITHIN CEILING SHOULD NOT BE LOCATED NEAR CEILING

PROJECTORS. THESE DEVICES COULD INDUCE VIBRATION AT THE PROJECTORS. TAKE

PRECAUTION TO LIMIT ANY VIBRATION WITHIN THE CEILING THAT COULD BE TRANSFERRED TO

THE PROJECTORS.

3. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT

IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.

4. EACH FLOORBOX SHOULD BE ON ITS OWN DEDICATED 20A CIRCUIT.

LIGHTING / DRAPE NOTES:

1. PENDANT LIGHT FIXTURES TO BE CAREFULLY COORDINATED SO THAT THEY DO NOT IMPEDE

DATA PROJECTORS CONE.

2. LIGHTING ZONES TO BE CIRCUITED AND DIMMABLE. FRONT ZONE OF LIGHTING CLOSEST TO

PROJECTION SCREENS SHOULD BE ON A SEPARATE ZONE SO THAT IT CAN BE DIMMED OR

SHUT OFF IF NECESSARY.

3. WINDOW TREATMENTS SHOULD BE PROVIDED WHERE AMBIENT LIGHT FROM OUTDOORS OR

OTHER LIGHT SOURCES THAT HAVE THE POTENTIAL TO AFFECT THE PROJECTED IMAGES ON

THE PROJECTION SCREENS.

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

LCD MONITOR 188 4 641 2564

PROJECTOR 528 1 1800 1800

EQUIPMENT RACK 1500 1 5115 5115

TOTAL BTU: 7557 9480

J-1

MAIN PULL BOX WITH (2)

QUAD POWER, (4) LAN,

AND (2) CATV

D-1

AV-A

MIDDLE ATLANTIC

WRK-44SA-27 AV

EQUIPMENT RACK

TO J-1

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

D-17

AV-C

EXTRON CABLE CUBBY

500D-18

AV-C

EXTRON CABLE CUBBY

1400 PER TABLE

TYP. 4 TABLES

D-19

AV-D

MIDDLE ATLANTIC SRSR

EQUIPMENT RACK INSIDE

DESK

Page 6: AV00 - Rhode Island

SLAB

FLOOR

CEILING

ELECTRICAL SCHEDULE

SYM. DESCRIPTION

STUBBED

CONDUIT

CEILING POWER OUTLET - 120V AC

AC CLOCK RECEPTACLE - 120V AC

AC DUPLEX OUTLET - 120V AC

AC QUAD OUTLET - 120V AC

LAN WITH QUANTITY

RIGID

CONDUIT

ANALOG LINE WITH QUANTITY

WALL PHONE

CATV

J-BOX

PLENUM

CABLE

CEILING PULL AREA

SHADE LVC

LIGHTING LVC

SCREEN LVC

LIGHT SWITCH

SCREEN SWITCH

J-

CB-

SH

LVC

LT

LVC

SCR

LVC

LT

SW

SS

SW

JUNCTION BOX SCHEDULE

BOX #: SIZE: FUNCTION: LOCATION:

ADD'L CABLE

BEYOND BOX

AFF

AV CLOSET

J-1 8x8 RACK PULL BOX SEE AV FLOOR PLAN 15'-0" 18"

SEMINAR / LECTURE 100A

J-2A 1 GANG SCREEN SWITCH SEE AV FLOOR PLAN 5'-0" 48"

AV-1A 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 18"

AV-2A 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 18"

FB-1A MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A

FB-2A MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A

CB-1A MANUF. PLENUM CEILING BOX SEE AV RCP 10'-0" AFC

ACTIVE LEARNING CLASSROOM 100C

J-2C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 66"

J-3C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 66"

J-4C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 66"

J-5C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 66"

J-6C 1 GANG SCREEN SWITCH SEE AV FLOOR PLAN 5'-0" 48"

FB-1C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A

FB-2C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A

FB-3C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A

FB-4C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A

FB-5C MANUF. FLOOR BOX SEE AV FLOOR PLAN 10'-0" N/A

CB-1C MANUF. PLENUM CEILING BOX SEE AV RCP 10'-0" AFC

NOTES:

1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.

2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS

3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.

4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.

5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.

6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,

FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME

PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS

7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.

8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS

9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL

DEVICES.

J-1

4

2

CB-1A

J-2A

AV-2A AV-1A

1 1

FB-2A FB-1A

2 2

FB-1C

2

FB-2C

2

CB-1C

J-6C

J-2C 1

FB-3C

2

J-3C 1

FB-4C

2

J-4C 1

FB-5C

2

J-5C 1

ACTIVE LEARNING

CLASSROOM 100C

SEMINAR/ LECTURE 100A

CEILING SPEAKERS

TYP. 6

CEILING SPEAKERS

TYP. 6

PROJECTOR PROJECTOR

SCREEN

SWITCH

SCREEN

SWITCH

(4) 1 1/4"

CONDUITS

48" LCD MONITOR 48" LCD MONITOR 48" LCD MONITOR 48" LCD MONITOR

1-1/4"

CONDUIT

1-1/4"

CONDUIT

1-1/4"

CONDUIT

1-1/4"

CONDUIT

1-1/4"

CONDUIT

1-1/4"

CONDUIT

1-1/4"

CONDUIT

1-1/4"

CONDUIT

TEACHERS STATION

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SEMINAR 100A &ACTIVE LEARNING 100C

CONDUIT RISER

AV03.1

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

Page 7: AV00 - Rhode Island

22

2

2

SLAB

FLOOR

CEILING

SLAB

ELECTRICAL SCHEDULE

SYM. DESCRIPTION

STUBBED

CONDUIT

CEILING POWER OUTLET - 120V AC

AC CLOCK RECEPTACLE - 120V AC

AC DUPLEX OUTLET - 120V AC

AC QUAD OUTLET - 120V AC

LAN WITH QUANTITY

RIGID

CONDUIT

ANALOG LINE WITH QUANTITY

WALL PHONE

CATV

J-BOX

PLENUM

CABLE

CEILING PULL AREA

SHADE LVC

LIGHTING LVC

SCREEN LVC

LIGHT SWITCH

SCREEN SWITCH

J-

CB-

SH

LVC

LT

LVC

SCR

LVC

LT

SW

SS

SW

JUNCTION BOX SCHEDULE

BOX #: SIZE: FUNCTION: LOCATION:

ADD'L CABLE

BEYOND BOX

AFF

EDITING SUITE ROOM 101

J-1 2 GANG PULL AREA SEE AV FLOOR PLAN

10'-0" 15"

J-2 3 GANG MONITOR SEE AV FLOOR PLAN

4'-0" 60"

J-3 5 GANG INTERFACE PLATE SEE AV FLOOR PLAN

3'-0" 36"

J-4 3 GANG CONTROL INTERFACE SEE AV FLOOR PLAN

3'-0"

36"

NOTES:

1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.

2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS

3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.

4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.

5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.

6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,

FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME

PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS

7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.

8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS

9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL

DEVICES.

2

J-1

J-2

COUNTER

J-3

J-4

2

LCD MONITOR

2 2

CAT5

CAT5

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

EDITING SUITE ROOM101 - FLOOR PLAN &

CONDUIT RISER

AV04

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 1/2" = 1'-0"

EDITING SUITE ROOM 101 PLAN

1

2.5" THROUGH COUNTER GROMMETT

(BY OTHERS)

Scale: NTS

EDITING SUITE ROOM 101 CONDUIT RISER

3

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

LCD MONITOR 55 1 188 188

EQUIPMENT RACK 600 1 2046 2046

TOTAL BTU: 2234 2234

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT

IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.

J-2

3 GANG PULL BOX FOR

MONITOR WITH AC CLOCK

RECEPTACLE

J-1

2 GANG PULL BOX FOR RACK -

POWER AND LAN TO BE

LOCATED AT RACKLOCATION IN

CORNER

J-4

BUTTON CONTROLLER

MOUNTED INTO 3 GANG

BOX

Scale: 3/4" = 1'-0"

EDITING SUITE ROOM 101 ELEVATION

2

J-2

3 GANG PULL BOX FOR

MONITOR WITH AC CLOCK

RECEPTACLE

J-1

2 GANG PULL BOX FOR RACK -

POWER AND LAN TO BE

LOCATED AT RACKLOCATION IN

CORNER

J-4

BUTTON CONTROLLER

MOUNTED INTO 3 GANG

BOX

CABLING TO RUN ALONG

UNDERSIDE OF

COUNTERTOP FROM J-1

TO RACK

15

"

36

"

15

"

D-8

AV-B

AV RACK LOCATED IN

CORNER WITH QUAD

POWER AND LAN

D-6

AV-A

SAMSNUG DM48D 48" LCD

MONITOR

D-8

AV-B

AV RACK LOCATED IN

CORNER WITH QUAD

POWER AND LAN

D-6

AV-A

SAMSUNG DM48D 48" LCD

MONITOR

D-7

AV-B

J-3

CUSTOM 5 GANG AV

INPUT PLATE

D-7

AV-B

J-3

CUSTOM 5 GANG AV

INPUT PLATE

60

"

CONVENIENCE OUTLETS - QUAD

POWER AND LAN LOCATED

BELOW COUNTER TOP

TYP. 2 LOCATIONS

FOSTEX PM0.4d PROGRAM

MONITOR SPEAKERS

*PROVIDE CABLE GROMMET

FOR SPEAKERS

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

*CONNECT POWER FOR MONITOR

SPEAKERS AT AV RACK

FURNITURE NOTES:

1. PROVIDE CUT AND GROMMET IN TOP FOR SPEAKER CABLING.

2. AV CONTRACTOR SHALL PROVIDE WIRE MANAGEMENT CHANNEL FOR CABLING BETWEEN

EQUIPMENT AT TABLE SURFACE AND PATHWAY TO AV RACK.

Page 8: AV00 - Rhode Island

22

SLAB

FLOOR

CEILING

SLAB

ELECTRICAL SCHEDULE

SYM. DESCRIPTION

STUBBED

CONDUIT

CEILING POWER OUTLET - 120V AC

AC CLOCK RECEPTACLE - 120V AC

AC DUPLEX OUTLET - 120V AC

AC QUAD OUTLET - 120V AC

LAN WITH QUANTITY

RIGID

CONDUIT

ANALOG LINE WITH QUANTITY

WALL PHONE

CATV

J-BOX

PLENUM

CABLE

CEILING PULL AREA

SHADE LVC

LIGHTING LVC

SCREEN LVC

LIGHT SWITCH

SCREEN SWITCH

J-

CB-

SH

LVC

LT

LVC

SCR

LVC

LT

SW

SS

SW

JUNCTION BOX SCHEDULE

BOX #: SIZE: FUNCTION: LOCATION:

ADD'L CABLE

BEYOND BOX

AFF

RECORDING TUTORING ROOM 104

J-1 2 GANG PULL AREA SEE AV FLOOR PLAN

10'-0" 36"

J-2 3 GANG MONITOR SEE AV FLOOR PLAN

4'-0" 48"

J-3 5 GANG INTERFACE PLATE SEE AV FLOOR PLAN

3'-0" 32"

J-4 3 GANG CONTROL INTERFACE SEE AV FLOOR PLAN

3'-0" 32"

J-5 2 GANG TABLE FEED SEE AV FLOOR PLAN

6'-0" 15"

NOTES:

1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.

2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS

3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.

4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.

5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.

6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,

FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME

PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS

7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.

8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS

9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL

DEVICES.

2

J-1

J-2

TABLE

J-3

J-4

2

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

RECORDING TUTORINGROOM 104 - PLAN &

CONDUIT RISER

AV05

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 3/4" = 1'-0"

RECORDING/TUTORING 104 PLAN

1

Scale: NTS

RECORDING/TUTORING 104 CONDUIT RISER

3

J-2

3 GANG PULL BOX FOR

MONITOR WITH AC CLOCK

RECEPTACLE

J-1

2 GANG PULL BOX FOR RACK

WITH POWER AND LAN

J-4

BUTTON CONTROLLER

MOUNTED TO 1 GANG

BOX

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

LCD MONITOR 55 1 188 188

EQUIPMENT RACK 500 1 1705 1705

TOTAL BTU: 1893 1893

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT

IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.

3. WALL MOUNTED EQUIPMENT RACKS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING

THAT IS RATED FOR 5 TIMES THE WEIGHT OF THE EQUIPMENT RACK

Scale: 3/4" = 1'-0"

RECORDING/TUTORING 104 ELEVATION

2

J-2

3 GANG PULL BOX FOR

MONITOR WITH 2 AC CLOCK

RECEPTACLES

J-4

BUTTON CONTROLLER

MOUNTED INTO 3 GANG

BOX

J-1

2 GANG PULL BOX FOR RACK

WITH POWER AND LAN

D-6

AV-A

SAMSUNG M48D 48" LCD

MONITOR

D-10

AV-B

CHIEF NW2 WALL

MOUNTED RACK

D-10

AV-B

CHIEF NW2 WALL

MOUNTED RACK

D-6

AV-A

SAMSUNG DM48D 48" LCD

MONITOR

D-7

AV-B

J-3

CUSTOM 5 GANG AV

INPUT PLATE

D-7

AV-B

J-3

CUSTOM 5 GANG AV

INPUT PLATE

J-5

2 GANG PLATE FOR TABLE BOX

CONNECTION BELOW TABLE

32

"

36

"

48

"

15

"

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

MACKIE HRmk2

REFERENCE MONITOR

(TYP. 2)

Page 9: AV00 - Rhode Island

14

14

SLAB

FLOOR

CEILING

SLAB

ELECTRICAL SCHEDULE

SYM. DESCTIPTION

STUBBED

CONDUIT

CEILING POWER OUTLET - 120V AC

AC CLOCK RECEPTACLE - 120V AC

AC DUPLEX OUTLET - 120V AC

AC QUAD OUTLET - 120V AC

LAN WITH QUANTITY

RIGID

CONDUIT

ANALOG LINE WITH QUANITY

WALL PHONE

CATV

J-BOX

PLENUM

CABLE

CEILING PULL AREA

SHADE LVC

LIGHTING LVC

SCREEN LVC

LIGHT SWITCH

SCREEN SWITCH

J-

CB-

SH

LVC

LT

LVC

SCR

LVC

LT

SW

SS

SW

JUNCTION BOX SCHEDULE

BOX #: SIZE: FUNCTION: LOCATION:

ADD'L CABLE

BEYOND BOX

AFF

SPEAKING WRITING LAB 106

J-1A 1 GANG PULL AREA SEE AV FLOOR PLAN

10'-0" 15"

J-1B 1 GANG PULL AREA SEE AV FLOOR PLAN

10'-0" 15"

J-2A 1 GANG MONITOR SEE AV FLOOR PLAN

5'-0" 48"

J-2B 1 GANG MONITOR SEE AV FLOOR PLAN

5'-0" 48"

AV-1A MANUF. TABLE BOX SEE AV FLOOR PLAN

5'-0" N.A.

AV-1B MANUF. TABLE BOX SEE AV FLOOR PLAN

5'-0" N.A.

NOTES:

1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.

2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS

3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.

4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.

5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.

6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,

FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME

PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS

7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.

8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS

9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL

DEVICES.

4J-1A

J-2A 1 J-2B 1

4J-1B

AV-1A AV-1B

CAT5

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SPEAKING WRITINGLAB 106 - FLOOR PLAN

& CONDUIT RISER

AV06

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 3/8" = 1'-0"

SPEAKING/WRITING LAB 106 - FLOOR PLAN

1

Scale: NTS

SPEAKING/WRITING LAB 106 - CONDUIT RISER

3

Scale: 3/4" = 1'-0"

SPEAKING/WRITING LAB 106 - ELEVATION (TYP. OF 2)

2

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

LCD MONITOR 50 2 171 341

TOTAL BTU: 171 341

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT

IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.

J-2B

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

J-1B

1 GANG BOX FOR AV

WITH QUAD POWER AND

(4) LAN

EXTRON CABLE CUBBY 700

TABLE BOX

J-2A

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

J-1A

1 GANG BOX FOR AV

WITH QUAD POWER AND

(4) LAN

EXTRON CABLE CUBBY 700

TABLE BOX

J-2A

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

J-1A

1 GANG BOX FOR AV

WITH QUAD POWER AND

(4) LAN

D-6

AV-A

SAMSUNG DM48D 48" LCD

MONITOR

D-6

AV-A

SAMSUNG DM48D 48" LCD

MONITOR

TYP. 2

D-6

AV-A

SAMSUNG DM48D 48" LCD

MONITOR

15

"

48

"

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

Page 10: AV00 - Rhode Island

4

CATV

1

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SCREENING LECTUREROOM 103 - FLOOR

PLAN & RCP

AV07

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 3/8" = 1'-0"

SCREENING/LECTURE ROOM 103 - FLOOR PLAN

1

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

98" LCD MONITOR 420 1 1432 1432

EQUIPMENT RACK 2000 1 6820 6820

TOTAL BTU: 8252 8252

FURNITURE NOTES:

1. MOVABLE TEACHING STATION WILL UTILIZE FLOOR BOXES SUPPLIED WITH POWER BY EC AND

LAN BY TEL/DATA.

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

J-1

WITH QUAD POWER, (4)

LAN, AND CATV

FB-1

WIREMOLD CRFB POKE-THRU

DEVICE MOUNTED TO FACE OF

SEATING RISER WITH POWER, LAN,

AND AV CONNECTIVITY

FB-2

WIREMOLD CRFB POKE-THRU DEVICE

MOUNTED TO FACE OF SEATING RISER

WITH POWER, LAN, AND AV

CONNECTIVITY

D-1

AV-A

MIDDLE ATLANTIC

MRK-24-26

EQUIPMENT RACK

D-15

AV-C

J-3

FRONT RIGHT LEON VAULT

ULTIMA PROGRAM SPEAKER

TYP. 2 LOCATIONS

J-7

REAR RIGHT CHANNEL

TANNOY VX 5.2

PROGRAM SPEAKER

J-8

REAR LEFT CHANNEL

TANNOY VX 5.2

PROGRAM SPEAKER

J-6

SIDE LEFT CHANNEL

TANNOY VX 5.2

PROGRAM SPEAKER

J-5

SIDE RIGHT CHANNEL

TANNOY VX 5.2

PROGRAM SPEAKER

TYP 4 LOCATIONS

D-12

AV-B

J-9

LEON A10UT IN-WALL

SUBWOOFER

J-4

FRONT LEFT

LEON VAULT ULTIMA

PROGRAM SPEAKER

J-2

CHIEF PAC521P BACK

BOX WITH POWER

D-14

AV-C

NEC X981UHD 98" LCD

MONITOR ON CHIEF

MOUNT W/ SOUNDBAR

BELOW

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

D-17

AV-C

EXTRON CABLE CUBBY 500

AV-19

AV-D

MIDDLE ATLANTIC

SRSR RACK INSIDE OF

TEACHERS STATION

Page 11: AV00 - Rhode Island

SLAB

FLOOR

CEILING

SLAB

ELECTRICAL SCHEDULE

SYM. DESCRIPTION

STUBBED

CONDUIT

CEILING POWER OUTLET - 120V AC

AC CLOCK RECEPTACLE - 120V AC

AC DUPLEX OUTLET - 120V AC

AC QUAD OUTLET - 120V AC

LAN WITH QUANTITY

RIGID

CONDUIT

ANALOG LINE WITH QUANITY

WALL PHONE

CATV

J-BOX

PLENUM

CABLE

CEILING PULL AREA

SHADE LVC

LIGHTING LVC

SCREEN LVC

LIGHT SWITCH

SCREEN SWITCH

J-

CB-

SH

LVC

LT

LVC

SCR

LVC

LT

SW

SS

SW

JUNCTION BOX SCHEDULE

BOX #: SIZE: FUNCTION: LOCATION:

ADD'L CABLE

BEYOND BOX

AFF

LECTURE ROOM SM-01

J-1 8x8 RACK PULL BOX SEE AV FLOOR PLAN 15'-0" 18"

J-2 MANUF. MONITOR BACK BOX SEE AV FLOOR PLAN 5'-0" 89"

J-3 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 103"

J-4 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 103"

J-5 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 105"

J-6 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 105"

J-7 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 87"

J-8 1 GANG SPEAKER PULL BOX SEE AV FLOOR PLAN 5'-0" 87"

J-9 MANUF. IN WALL SUBWOOFER SEE AV FLOOR PLAN 5'-0" N/A

FB-1 MANUF. FLOOR BOX FACE OF SEATING RISER 15'-0"

OF

RISER

FB-2 MANUF. FLOOR BOX FACE OF SEATING RISER 15'-0"

OF

RISER

J-1

(4) 1-1/4"

CONDUITS

4

NOTES:

1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE

SPECIFIED.

2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL

CONDUITS

3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE

NUMBERS AND CONDUIT INTERCONNECT ONLY.

4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX

LOCATION OR EXACT CONDUIT ROUTING.

5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND

ELECTRICAL PRINTS.

6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED

PROJECTORS, LCD OR PLASMA MONITORS, FLOOR BOXES WITH AV,

AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT

BE ON THE SAME PHASE AS COMPRESSORS, MOTORS OR LIGHT

DIMMING SYSTEMS.

7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS

INDICATED.

8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL

OUT LOCATIONS

9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH

ARCHITECTS PRIOR TO INSTALLATION OF ALL DEVICES.

FC-1

FLOOR

CORE

POKE-THRU

2

FB-1 FB-2

2

J-2

J-3J-4

J-5J-6J-7J-8

IN-WALL SUBWOOFER

REAR

SPEAKERS

SIDE

SPEAKERS

98" 4K LCD MONITOR

LEFT

SPEAKER

RIGHT

SPEAKER

INSTRUCTORS STATION

1

SOUNDBAR (MOUNTED BELOW TV)

J-9

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SCREENING LECTUREROOM 103 -

ELEVATIONS &CONDUIT RISER

AV08

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 3/8" = 1'-0"

SCREENING/LECTURE ROOM 103 - ELEVATION

2

Scale: 3/8" = 1'-0"

SCREENING/LECTURE ROOM 103 - SECTION

1

Scale: NTS

SCREENING/LECTURE ROOM 103 - CONDUIT RISER

3

7'-3

"

86 3/4"

49

5

/8

"

65

7

/8

"

90

3

/4

"

1 1/8"

1"

11

6 1

/2

"

10

3 1

/2

"

97

1

/8

"

D-11

AV-B

J-3

FRONT RIGHT TANNOY VS

LEON VAULT SPEAKER

PROGRAM SPEAKER

TYP. 2 LOCATIONS

J-4

FRONT LEFT CHANNEL

LEON VAULT SPEAKER

PROGRAM SPEAKER

J-2

CHIEF PAC521P BACK

BOX WITH POWER

D-14

AV-C

NEC X981UHD 98" 4K

LCD MONITOR ON

CHIEF MOUNT

57

1

/2

"

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

7"

SOUND BAR WIDTH IS

EDGE-TO-EDGE WITHIN NICHE.

VERIFY DIMENSION IN FIELD BEFORE

ORDERING

SUBWOOFER

LEON ACS10UT IN-WALL

SUBWOOFER. REMOVE STAND

BEFORE INSTALLATION

D-15

AV-C

CENTER CHANNEL

LEON HZ ULTIMA

SOUNDBAR WALL MOUNTED

UNDER MONITOR.

Page 12: AV00 - Rhode Island

1

1

4

4

SLAB

FLOOR

CEILING

SLAB

ELECTRICAL SCHEDULE

SYM. DESCRIPTION

STUBBED

CONDUIT

CEILING POWER OUTLET - 120V AC

AC CLOCK RECEPTACLE - 120V AC

AC DUPLEX OUTLET - 120V AC

AC QUAD OUTLET - 120V AC

LAN WITH QUANTITY

RIGID

CONDUIT

ANALOG LINE WITH QUANTITY

WALL PHONE

CATV

J-BOX

PLENUM

CABLE

CEILING PULL AREA

SHADE LVC

LIGHTING LVC

SCREEN LVC

LIGHT SWITCH

SCREEN SWITCH

J-

CB-

SH

LVC

LT

LVC

SCR

LVC

LT

SW

SS

SW

JUNCTION BOX SCHEDULE

BOX #: SIZE: FUNCTION: LOCATION:

ADD'L CABLE

BEYOND BOX

AFF

EDITING SUITE 101

J-1A 1 GANG PULL AREA SEE AV FLOOR PLAN

10'-0" 15"

J-1B 1 GANG PULL AREA SEE AV FLOOR PLAN

10'-0" 15"

J-2A 1 GANG MONITOR SEE AV FLOOR PLAN

5'-0" 48"

J-2B 1 GANG MONITOR SEE AV FLOOR PLAN

5'-0" 48"

J-3A 5 GANG CUSTOM PLATE SEE AV FLOOR PLAN

5'-0" 32"

J-3B 5 GANG CUSTOM PLATE SEE AV FLOOR PLAN

5'-0" 32"

NOTES:

1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.

2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS

3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.

4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.

5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.

6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,

FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME

PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS

7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.

8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS

9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL

DEVICES.

J-3A

J-2A 1

J-3B

J-2B 1

4

J-1A

4

J-1B

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

COLLABORATE EDITSUITES 108 & 110 -

FLOOR PLAN &CONDUIT RISER

AV09

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 1/2" = 1'-0"

COLLABORATE EDIT SUITES 108 & 110 PLAN

1

J-2B

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

J-1B

1 GANG BOX FOR AV

WITH QUAD POWER AND

(4) LAN

EXTRON CABLE CUBBY 1400

TABLE BOX

J-2A

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

J-1A

1 GANG BOX FOR AV

WITH QUAD POWER AND

(4) LAN

EXTRON CABLE CUBBY 1400

TABLE BOX

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

LCD MONITOR 55 2 188 375

TOTAL BTU: 188 375

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT

IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.

3. CARE SHOULD BE TAKEN TO OFFSET BOXES TO AVOID INTERFERING WITH OPPOSITEWALL.

Scale: NTS

COLLABORATE EDIT SUITES 108 & 110 - CONDUIT RISER

3

Scale: 3/4" = 1'-0"

COLLABORATE EDIT SUITES 108 & 110 - ELEVATION

2

J-2A

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

J-1A

1 GANG BOX FOR AV

WITH QUAD POWER AND

(4) LAN

D-6

AV-A

SAMSUNG DM48D 48" LCD

MONITOR

TYP. 2

D-6

AV-A

SAMSUNG DM48D 48" LCD

MONITOR

D-7

AV-B

5 GANG BOX FOR AV

D-7

AV-B

J-3A

5 GANG BOX FOR AV

D-7

AV-B

J-3A

5 GANG BOX FOR AV

15

"

32

"

48

"

D-6

AV-B

SAMSUNG DM48D 48" LCD

MONITOR

TYP. 2

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

Page 13: AV00 - Rhode Island

1

4

CATV

1 1

1

S

S

S

S

S

S

S

S

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

LIVING ROOM 112 -FLOOR PLAN RCP

ELEVATION CONDUITRISER

AV10

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 1/4" = 1'-0"

LIVING ROOM 112 - FLOOR PLAN

1

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

LCD MONITOR 55 3 188 563

PROJECTOR 480 1 1637 1637

EQUIPMENT RACK 1000 1 3410 3410

TOTAL BTU: 5234 5609

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

2. MECHANICAL DEVICES LOCATED WITHIN CEILING SHOULD NOT BE LOCATED NEAR CEILING

PROJECTORS. THESE DEVICES COULD INDUCE VIBRATION AT THE PROJECTORS. TAKE

PRECAUTION TO LIMIT ANY VIBRATION WITHIN THE CEILING THAT COULD BE TRANSFERRED TO

THE PROJECTORS.

3. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT

IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.

LIGHTING / DRAPE NOTES:

1. PENDANT LIGHT FIXTURES TO BE CAREFULLY COORDINATED SO THAT THEY DO NOT IMPEDE

DATA PROJECTORS CONE.

2. LIGHTING ZONES TO BE CIRCUITED AND DIMMABLE. FRONT ZONE OF LIGHTING CLOSEST TO

PROJECTION SCREENS SHOULD BE ON A SEPARATE ZONE SO THAT IT CAN BE DIMMED OR

SHUT OFF IF NECESSARY.

3. WINDOW TREATMENTS SHOULD BE PROVIDED WHERE AMBIENT LIGHT FROM OUTDOORS OR

OTHER LIGHT SOURCES THAT HAVE THE POTENTIAL TO AFFECT THE PROJECTED IMAGES ON

THE PROJECTION SCREENS.

Scale: 1/4" = 1'-0"

LIVING ROOM 112 - RCP

2

J-2C

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

AV-1C

2 GANG BOX FOR AV

INPUT PLATE WITH

POWER AND LAN

J-1C

3 GANG BOX FOR AV

BUTTON PANEL

J-3C

1 GANG BOX FOR AV

J-2B

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

AV-1B

2 GANG BOX FOR AV

INPUT PLATE WITH

POWER AND LAN

J-1B

3 GANG BOX FOR AV

BUTTON PANEL

J-3B

1 GANG BOX FOR AV

J-2A

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

AV-1A

2 GANG BOX FOR AV

INPUT PLATE WITH

POWER AND LAN

J-1A

3 GANG BOX FOR AV

BUTTON PANEL

J-3A

1 GANG BOX FOR AV

J-1

4 GANG PULL BOX FOR

AV WITH QUAD POWER,

(4) LAN, AND CATV

CB-1

PULL AREA FOR

PROJECTOR WITH

POWER AND LAN

Scale: 3/4" = 1'-0"

LIVING ROOM 112 - MONITOR ELEVATION (TYPICAL)

3

J-2C

1 GANG BOX FOR AV

WITH AC CLOCK

RECEPTACLE AND LAN

AV-1C

2 GANG BOX FOR AV

INPUT PLATE WITH

POWER AND LAN

J-1C

3 GANG BOX FOR AV

BUTTON PANEL

J-3C

1 GANG BOX FOR AV

32

"

J-4

1 GANG SCREEN SWITCH

D-4

AV-A

TANNOY CVS6 CEILING

SPEAKERS

TYP. 8

D-9

AV-B

DALITE TENSIONED

COSMOPOLITAN 76.25"H X

122"W CEILING MOUNTED

ELECTRIC PROJECTION

SCREEN

D-2

AV-A

EPSON G6470WU

PROJECTOR WITH

STANDARD LENS

D-1

AV-A

MIDDLE ATLANTIC

WRK-44SA-27

D-5

AV-A

RECESSED SAMSUNG

DM48D 48" LCD MONITOR

18' THROW DISTANCE

48

"

15

"

TO J-1

D-5

AV-A

RECESSED SAMSUNG

DM48D 48" LCD MONITOR

MOUNTED ON CHIEF

PNRIW + PAC501

TYP. 3

UNDER-CARPET

PERIMETER LOOP

SYSTEM

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

TO J-1

AV-2

2 GANG BOX FOR AV

WITH AC RECEPTACLE

AND LAN

J-5

TOUCH PANEL W/ MFR PRE CONSTRUCTION BOX

Page 14: AV00 - Rhode Island

22

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

ENTRANCE VIDEOWALL

AV11

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale: 1/2" = 1'-0"

ENTRANCE VIDEO WALL FLOOR PLAN

1

ESTIMATED POWER CONSUMPTION & BTU LOAD CHART

EQUIPMENT WATTS (EACH) QTY. BTU (EACH) BTU (TOTAL)

LCD MONITOR 120 4 409 1637

TOTAL BTU: 409 1637

GENERAL NOTES:

1. ELECTRICAL SERVICES SHOWN ON THIS DRAWING ARE FOR AV REQUIREMENTS ONLY. THESE

AV CIRCUITS SHOULD ALL BE ON THE SAME ELECTRICAL PHASE AND ON THEIR OWN

DEDICATED CIRCUITS.

2. WALL MOUNTED LCD MONITORS SHOULD BE PROVIDED WITH WALL SUPPORT BLOCKING THAT

IS RATED FOR 5 TIMES THE WEIGHT OF THE LCD MONITOR AND MOUNT.

J-6

2 GANG PULL BOX FOR

AV WITH (2) LAN AND

QUAD POWER

Scale: 1" = 1'-0"

ENTRANCE VIDEO WALL ELEVATION

2

J-7

2 GANG PULL BOX FOR

AV WITH (2) LAN AND

QUAD POWER

J-6

2 GANG PULL BOX FOR

AV WITH (2) LAN AND

QUAD POWER

J-7

2 GANG PULL BOX FOR

AV WITH (2) LAN AND

QUAD POWER

74

"

51

1

/4

"

22

3

/4

"

EQ. EQ.

45

5

/8

"

80 5/8"

40 1/4"

Scale: 3/8" = 1'-0"

ENTRANCE VIDEO WALL CEILING PLAN

3

CB-2

PLENUM CEILING BOX FOR

DIRECTIONAL SPEAKER

D-15

AV-C

(4) PRIMEVIEW PRV46

46" LED MONITORS

ARRANGED IN A 2x2 TILE

WALL

39

3

/4

"

D-15

AV-C

(4) PRIMEVIEW PRV49SNG

49" LED MONITORS

ARRANGED IN A 2x2 TILE

WALL

2

AV11

3 3/4"

3 5

/8

"

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

Page 15: AV00 - Rhode Island

SLAB

FLOOR

CEILING

SLAB

ELECTRICAL SCHEDULE

SYM. DESCRIPTION

STUBBED

CONDUIT

CEILING POWER OUTLET - 120V AC

AC CLOCK RECEPTACLE - 120V AC

AC DUPLEX OUTLET - 120V AC

AC QUAD OUTLET - 120V AC

LAN WITH QUANTITY

RIGID

CONDUIT

ANALOG LINE WITH QUANTITY

WALL PHONE

CATV

J-BOX

PLENUM

CABLE

CEILING PULL AREA

SHADE LVC

LIGHTING LVC

SCREEN LVC

LIGHT SWITCH

SCREEN SWITCH

J-

CB-

SH

LVC

LT

LVC

SCR

LVC

LT

SW

SS

SW

JUNCTION BOX SCHEDULE

BOX #: SIZE: FUNCTION: LOCATION:

ADD'L CABLE

BEYOND BOX

AFF

AV CLOSET

J-1 8X8 RACK PULL BOX SEE AV FLOOR PLAN 15' 18"

LIVING ROOM

J-1A 3 GANG BUTTON PANEL SEE AV FLOOR PLAN 5'-0" 32"

J-1B 3 GANG BUTTON PANEL SEE AV FLOOR PLAN 5'-0" 32"

J-1C 3 GANG BUTTON PANEL SEE AV FLOOR PLAN 5'-0" 32"

J-2A 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 48"

J-2B 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 48"

J-2C 1 GANG MONITOR PULL BOX SEE AV FLOOR PLAN 5'-0" 48"

J-3A 1 GANG HEADPHONE PLATE SEE AV FLOOR PLAN 5'-0" 32"

J-3B 1 GANG HEADPHONE PLATE SEE AV FLOOR PLAN 5'-0" 32"

J-3C 1 GANG HEADPHONE PLATE SEE AV FLOOR PLAN 5'-0" 32"

J-4 1 GANG SCREEN SWITCH SEE AV FLOOR PLAN 5'-0" 48"

J-5 MFR CONTROL PANEL SEE AV FLOOR PLAN 5'-0"

4'-6"

AV-1A 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"

AV-1B 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"

AV-1C 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"

AV-2 2 GANG AV INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"

CB-1 MANUF PLENUM CEILING BOX SEE AV RCP 10'-0" AFC

ENTRANCE VIDEO WALL

J-6 2 GANG MONITOR PULL SEE AV FP 10'-0" 74"

J-7 2 GANG MONITOR PULL SEE AV FP 10'-0" 74"

CB-2 MANUF CEILING BOX SEE AV RCP 10'-0" AFC

TECH DIRECTOR OFFICE

AV-3 2 GANG INPUT PLATE SEE AV FLOOR PLAN 5'-0" 15"

J-1C 3 GANG BUTTON PANEL SEE AV FLOOR PLAN 5'-0" 36"

NOTES:

1. ALL CONDUITS TO BE 1" DIAMETER UNLESS OTHERWISE SPECIFIED.

2. ELECTRICAL CONTRACTOR TO INSTALL PULL STRING IN ALL CONDUITS

3. THIS DRAWING INDICATES JUNCTION BOX NUMBERS, CABLE NUMBERS AND CONDUIT INTERCONNECT ONLY.

4. THIS DRAWINGS DOES NOT INDICATE EXACT JUNCTION BOX LOCATION OR EXACT CONDUIT ROUTING.

5. FOR FURTHER INFORMATION, REFER TO ARCHITECTURAL AND ELECTRICAL PRINTS.

6. 120VAC SERVICES FOR EQUIPMENT RACKS, CEILING MOUNTED PROJECTORS, LCD OR PLASMA MONITORS,

FLOOR BOXES WITH AV, AV WALL PLATES ETC TO SHARE SAME PHASE. THEY SHOULD NOT BE ON THE SAME

PHASE AS COMPRESSORS, MOTORS OR LIGHT DIMMING SYSTEMS

7. EC TO PROVIDE ALL CONDUITS AND JUNCTION BOXES AS INDICATED.

8. SEE AV FLOOR PLAN FOR ALL AV RELATED POWER AND LAN CALL OUT LOCATIONS

9. CONFIRM FINAL LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTS PRIOR TO INSTALLATION OF ALL

J-1

4

CB-1

J-4

AV-1A 1

J-6 2

J-7 2

CEILING SPEAKERS

TYP. 8

PROJECTOR

SCREEN

SWITCH

(4) 1 1/4"

CONDUITS

1-1/4"

CONDUIT

1-1/4"

CONDUIT

J-2A 1

J-1A J-3A

AV-1B 1

J-2B 1

J-1B J-3B

AV-1C 1

J-2C 1

J-1C J-3C

CB-2

AV-31

READING ROOM 112

ENTRANCE VIDEO WALL

TECH DIRECTOR OFFICE

AV

CLOSET

PERIMETER LOOP

UNDER FINISHED FLOOR

AV-2 1

J-5

J-5

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

LIVING ROOM ANDENTRANCE VIDEO

WALL CONDUIT RISER

AV12

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

THE GENERAL TRADES CONTRACTORS FOR THIS PROJECT MUST COORDINATE WITH THE

OWNER'S A/V VENDOR/INSTALLER AND TO COORDINATE ANY REQUIREMENTS FOR BLOCKING

AND SUPPORTS WITH THE APPROVED A/V EQUIPMENT.

Page 16: AV00 - Rhode Island

FB-2A

CRESTRON DM-TX-4K-100-1G

DM INPUT

OFE LAPTOP

HDMI

VGA+A

HDMI 1

VGA 1

CRESTRON DM-MD-4X1-C

PRESENTATION SWITCHER

(HDMI)HDMI 4

OPPO BDP103

BLU-RAY PLAYER

(HDMI)VGA 3

WOLFISION VZ-8LIGHT4

DOCUMENT CAMERA

(DM)

INSTRUCTOR STATION

DA-LITE LOW

VOLTAGE

PROJECTION

SCREEN WALL

SWITCH

J-2A

2

FROM 8X1 SWITCH

COM OUT

EFROM DM-MD16X16 SLOT 1

DM OUT

COM

DA-LITE 60"X 96" CEILING RECESSED

PROJECTION SCREEN

EPSON GW6470

4500 LUMENS PROJECTOR

CRESTRON

DM-RMC-4K-SCALER -C

C

HDMICB-1A

TANNOY CVS6

CEILING SPEAKERS

TAP @ 15W

TYP. 6

SP

AV RACK

100B

J-1

8G

A

FROM CP3N

RELAY 1 & 2

C

MONITOR1

OFE PC

LAN

2

TO OPPO

BLU-RAY

(C)

LAN

FFROM AMPLIFIER #1

A DM-MD16X16 INPUT 1

B TO NETWORK SWITCH

AV-1A J-1

OFE

KEYBOARD/MOUSE

USB

USB

J-1

D TO DM-MD16X16 INPUT 2

1

FROM PC

MONITOR OUT

OFE COMPUTER

MONITOR

MONITOR2

(C)

HDMI

1

TO PC

MONITOR

DM IN

TOUCH PANEL AV NET

CUSTOM

INPUT PANEL

C TO NETWORK SWITCH

DOCUMENT CAMERA DRAWER

EXTRON CABLE

CUBBY 500 #1

(TOP)

Middle Atlantic ProductsMiddle Atlantic Products

SRSR-2-12*

CONSULTANT RACK ID PANEL

SURGEX POWER STRIP

BLANK

OFE PC

OPPO BLU-RAY PLAYER

CRESTRON DM-MD8X1-4K-C SWITCHER

BLANK

BLANK

BLANK

EQUIPMENT RACK INSIDE TEACHER

STATION

(CAT6)

(CAT6)

EXTRON CABLE

CUBBY 500 #2

(SIDE)

HDMI

VGA+A

HDMI 2

VGA 2

HDMI 3

RACK IN SIDE LECTERN

NOTES

1. RACK MAY NEED TO BE CUT DOWN BY 1 RU, OR

MORE, TO FIT INSIDE OF TEACHER STATIONS. REFER

TO DRAWING A705 FOR DETAIL OF TEACHER

STATION.

2. FLOOR BOX DEVICE PLATES WILL BE PROVIDED BY

E.C. AV CONTRACTOR SHALL COORDINATE

REQUIRED DEVICE PLATES FOR INSTALLATION OF

AV.DEVICES.

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SEMINAR 100A AVSIGNAL FLOW

AV100

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 17: AV00 - Rhode Island

EPSON GW5650

4500 LUMENS PROJECTOR

OFE LAPTOP

YPbPr

Channel:

1080i

52-1

232-ATSC+1

USB

Air

CONTEMPORARY RESEARCH

ATSC-232 4

HDTV TUNER #1

(ROOM 100A)

HDMI DMC-4K-HD 8

CRESTRON

DM-RMC-4K-SCALER -C

AUDIO L

AUDIO R

1

DM

C- 4K

-H

DO

DM OUT 1

DM OUT2

SLOT 1

DM

C-4K

-C

O-H

D

SLOT 2

DMC-4K-C 3

CRESTRON DM-MD16X16

MATRIX SWITCH

8G

C

HDMI

J-1 CB-1A

E

DM-RMC-4K-SCALER-C

IN 100A

8G

DMC-4K-C 5

YPbPr

Channel:

1080i

52-1

232-ATSC+1

USB

Air

CONTEMPORARY RESEARCH

ATSC-232 4

HDTV TUNER #2

(ROOM 100C)

HDMI DMC-4K-HD 9

21 21 2121

CLASS 2 WIRING

10V 50mA

SIGNAL

LIMITER/PROTECT

100-240V 0.5A, 50-60 Hz

XPA 1002 Plus

V GC

ST

AN

DB

Y

G

8

14

10

8

6

12

2

0

8

26

18

14

12

10

8

6

4

2

0

4

XPA 1002 Plus

EXTRON XPA2001

AMPLIFIER

60-850-01 #1

A

A

AUDIO L

AUDIO R

2

21 21 2121

CLASS 2 WIRING

10V 50mA

SIGNAL

LIMITER/PROTECT

100-240V 0.5A, 50-60 Hz

XPA 1002 Plus

V GC

ST

AN

DB

Y

G

8

14

10

8

6

12

2

0

8

26

18

14

12

10

8

6

4

2

0

4

XPA 1002 Plus

TANNOY CVS6

CEILING SPEAKERS W/

TAP @ 15W

TYP. 6

EXTRON XPA2001

AMPLIFIER

60-850-01 #2

SP

A

A

ROOM 100A

ROOM 100C

AUDIO L

AUDIO R

1

DM

C- 4K

-H

DO

SLOT 5

A

A

ASSISTIVE

LISTENING

RACK PLATE

CRESTRON

TSW-1052-B-S

W/ TSW-1050-TTK-B-S

HDMI

VGA+A

HDMI 1

VGA 1

CRESTRON DM-MD8X1-4K-C

PRESENTATION SWITCHER

HDMI

HDMI 2

HDMI 3

OPPO BDP103

BLU-RAY PLAYER

HDMIHDMI 4

DOCUMENT CAMERA

8GDM OUT

MONITOR1

OFE PC

HDMI 2

LAN

CAT6

LAN CAT6

H TO NETWORK SWITCH

OFE

KEYBOARD/MOUSE

USB

USB

1

FROM PC

MONITOR OUT

OFE COMPUTER

MONITOR

MONITOR2 C

HDMI

1

TO PC

MONITOR

I TO NETWORK SWITCH

DOCUMENT CAMERA DRAWER

F

TO CEILING SPEAKERS

IN 100C

DMC-4K-C 6

DMC-4K-C 7

FB-1C

J-1

FROM STUDENT

TABLE #2

FROM STUDENT

TABLE #3

FB-3C

FROM STUDENT

TABLE #4

FB-4C

TO LAN IN

FLOOR BOX

J-1

CB-1C

SAMSUNG DM48

48" LCD MONITOR #1

CRESTRON

DM-RMC-4K-SCALER-C #1

C

HDMI

8G

J-2CJ-1

DM OUT 1

DM OUT2

SLOT 3

DM

C-4K

-C

O-H

D

J-3C

SAMSUNG DM48

48" LCD MONITOR #2

CRESTRON

DM-RMC-4K-SCALER-C #2

C

HDMI

8G

SAMSUNG DM48

48" LCD MONITOR #3

CRESTRON

DM-RMC-4K-SCALER-C #3

C

HDMI

8G

J-4CJ-1

DM OUT 1

DM OUT2

SLOT 4

DM

C-4K

-C

O-H

D

J-5C

SAMSUNG DM48

48" LCD MONITOR #4

CRESTRON

DM-RMC-4K-SCALER-C #4

C

HDMI

8G

A TO HEADPHONE AMP #1

A

A

A TO HEADPHONE AMP #2

A

A

A TO HEADPHONE AMP #3

A

A

A TO HEADPHONE AMP #4

A

A

HDMI 1

CONTACT 1

TALLY OUT 1

HDMI 2

CONTACT 2

TALLY OUT 2

HDMI 3

CONTACT 3

TALLY OUT 3

TALLY OUT 4

CONTACT 4

HDMI 4

EXTRON SW4 HDMI SWITCHER

60-841-04

AUDIOA

A

FROM MONITOR

AUDIO OUT

EXTRON CABLE CUBBY 1400

#1

HDMI / CONTROL

HDMI / CONTROL

HDMI / CONTROL

HDMI / CONTROL

H/PHONE1

H/PHONE2

H/PHONE3

H/PHONE4

2 TO CABLE CUBBY #1

3 TO CABLE CUBBY #2

5 TO CABLE CUBBY #4

A

A

A

A

OFE LAPTOP

HDMI / CONTROL

OFE LAPTOP

HDMI / CONTROL

OFE LAPTOP

OFE LAPTOP

CAT6

CAT6

STUDENT TABLE #1

(TYP OF 4)

ROLLS HA43 PRO

HEADPHONE AMP #1

RACK IN SIDE LECTERN

INSTRUCTOR STATION

UNDERSIDE OF TABLE

CRESTRON

DM-TX-4K-202-C

TRANSMITTER #1

DMC-4K-C 4

J-1FB-1C

HDMI1

RS232 C

HDMI

FB-2C

8G

8G

8G

8G

2

FROM H/P

AMP OUT 1

3

FROM H/P

AMP OUT 2

4

FROM H/P

AMP OUT 3

5

FROM H/P

AMP OUT 4

A

A

A

A

A

A

A

A

H/PHONE1A

H/PHONE2A

H/PHONE3A

4 TO CABLE CUBBY #3

H/PHONE4A

DMC-4K-C 1

DMC-4K-C 2

POE

A

FROM MONITOR

AUDIO OUT

8G

D

FROM MONITOR

AUDIO OUT

GFROM POE SWITCH

8G

8G

AV RACK

SP

DM IN

EXTRON CABLE CUBBY

500

CAT6

EXTRON CABLE CUBBY 1400

#2

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

ACTIVE LEARNING 100CAV FLOW -

PRESENTATIONSYSTEM

AV101

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 18: AV00 - Rhode Island

4

1

POWER

RESET

AMBER : 10/100Mbps green : 1000Mpbs

3DIAG 1 2

PoE

65 87

2 3 4 5

PoE SWITCH76 8

10

99 10

MANAGED POE

NETWORK SWITCH.

CRESTRON CP3N CONTROLLER

COMA

COMB

RELAY1/2

DA-LITE LOW

VOLTAGE

PROJECTION

SCREEN WALL

SWITCH

J-2A

C

J-1

C

RELAY3/4

DA-LITE LOW

VOLTAGE

PROJECTION

SCREEN WALL

SWITCH

J-6C

J-1

DA-LITE 60"X 96" CEILING RECESSED

PROJECTION SCREEN

DA-LITE 60"X 96" CEILING RECESSED

PROJECTION SCREEN

YPbPr

Channel:

1080i

52-1

232-ATSC+1

USB

Air

CONTEMPORARY RESEARCH

ATSC-232 4

HDTV TUNER #1 (100A)

YPbPr

Channel:

1080i

52-1

232-ATSC+1

USB

Air

CONTEMPORARY RESEARCH

ATSC-232 4

HDTV TUNER #2 (100C)

B

FROM TOUCH PANEL

100A

PORT 1

PORT 2

PORT 3

C

FROM LECTERN

SWITCHER 100A

C

HFROM TOUCH PANEL

IFROM AV SWITCHER

AV-1A

PORT 4

AV RACK

IN 100B

CRESTRON DM-MD16X16

MATRIX SWITCH

C

C

ROOM 100A

ROOM 100C

FB-1C

Middle Atlantic ProductsMiddle Atlantic Products

SRSR-2-12

CONSULTANT RACK ID PANEL

SURGEX POWER STRIP

BLANK

OFE PC

OPPO BLU-RAY PLAYER

CRESTRON DM-MD8X1-4K-C SWITCHER

BLANK

BLANK

BLANK

EQUIPMENT RACK INSIDE TEACHER

STATION

CAT6 G DM-MD16X16 POE IN

CAT6

CAT6

CAT6

CAT6

PORT5

PORT6

J-1

MIDDLE ATLANTIC HHCM-1 CABLE MANAGER

CATV TUNER #2

100C

CATV TUNER #1

100A

CISCO NETWORK SWITCH - CONTROL

CRESTRON CP3N CONTROL PROCESSOR

1 RU BLANK

1 RU BLANK

CRESTRON DM-MD16X16 RPS

DIGITAL MATRIX SWITCHER

EXTRON XPA AMPLIFIERS

1 RU BLANK

ADA OUTPUT PLATE

1 RU BLANK

CONSULTANT ID PANEL

MIDDLE ATLANTIC MRK-24-26

SHARED RACK 100B

SURGEX SX-1120-RT

1 RU BLANK

NOTES

1. RACK MAY NEED TO BE CUT DOWN BY 1 RU, OR

MORE, TO FIT INSIDE OF TEACHER STATIONS. REFER

TO DRAWING A705 FOR DETAIL OF TEACHER

STATION.

2. FLOOR BOX DEVICE PLATES WILL BE PROVIDED BY

E.C. AV CONTRACTOR SHALL COORDINATE

REQUIRED DEVICE PLATES FOR INSTALLATION OF

AV.DEVICES.

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

ACTIVE LEARNING 100CCONTROL FLOW

AV101.1

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

NOTES:

1. COORDINATE AS REQUIRED FOR LECTERN AND TEACHER STATION TO ALLOW

THE INSTALLATION OF THE EXTRON CABLE CUBBY.

2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.

3. LECTERN HAS ONE CABLE CUBBY INSTALLED ON TOP AND ONE INSTALLED ON

SIDE FOR ADA

Scale:6" = 1'-0"

LECTERN / TEACHER STATION CABLE CUBBY (TYP. 3)

1

EXTRON POWER MODULE

EXTRON CABLE CUBBY 500

(BRUSHED ALUMINUM)

CABLE GROMMET

(INCL. W/ CABLE CUBBY)

NOTES:

1. AVC TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM. COORDINATE AS

REQUIRED G TO ALLOW THE INSTALLATION OF THE EXTRON CABLE CUBBY.

2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.

Scale:6" = 1'-0"

STUDENT TABLE CABLE CUBBY DETAIL (TYP. 8)

2

EXTRON POWER MODULE

TYP 2

(INCL. W/ CABLE CUBBY)

EXTRON CABLE CUBBY 1400

CABLE GROMMET

(INCL. W/ CABLE CUBBY)

EXTRON AAP

3.5MM MINI TO CAPTIVE SCREW

TYP 2

EXTRON AAP BLANK

Page 19: AV00 - Rhode Island

SAMSUNG DM48E

48" LCD MONITOR

RS232

FOSTEX PMO .4D

ROOM

104

ROOM

108

ROOM

110

COMPUTER

AUDIO

HDMI

EDIT SUITE 101

XLR 1

XLR 2

XLR 3

XLR 4

XLR 5

XLR 6

HDMI 1

AUDIO 1

HDMI

DVI-D

AUDIO 1 (L&R)

A

A

A

A

A

A

VGA

AUDIO

CRESTRON MPC-M10

BUTTON CONTROLLER

WALL BELOW MONITOR

J-1

DVI1

COM A

VGA 1

OFE IMAC

J-5

C

PWR

J4

P

HDMI

A

A

J-3

TO SUITE 104

TO SUITE 104

TO SUITE 108

TO SUITE 108

TO SUITE 110

TO SUITE 110

COUNTER TOP

A

HDMI

VGA

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

URI EDIT ROOM 101

AV102

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 20: AV00 - Rhode Island

Middle Atlantic ProductsMiddle Atlantic Products

SRSR-2-12

CONSULTANT ID RACK

SURGEX POWER STRIP

BLANK

OFE PC

OPPO BLU-RAY PLAYER

BLANK

BLANK

EQUIPMENT RACK INSIDE LECTERN

EXTRON DTP CROSSPOINT 82 4K

OFE LAPTOP

HDMI

VGA+A

HDMI 1

VGA 1

(HDMI)HDMI 4

OPPO BDP103

BLU-RAY PLAYER

(HDMI)VGA 3

WOLFISION VZ-8LIGHT4

DOCUMENT CAMERA

RACK IN SIDE LECTERN

INSTRUCTOR LECTERN

MONITOR1

OFE PC

LAN

OFE

KEYBOARD/MOUSE

USB

USB

MONITOR2

(C)

HDMI

1

TO PC

MONITOR

DOCUMENT CAMERA DRAWER

EXTRON CABLE

CUBBY 500

(TOP)

EXTRON CABLE

CUBBY 500

(SIDE)

HDMI

VGA+A

HDMI 2

VGA 2

HDMI 3

a

1

2

3

4 6

5

EXTRON

DTP CROSSPOINT 82 4K

SCALING MATRIX SWITCHER #1

(DM-8G+)DTP1B

HDMI2A HDMI

OFE PC MONITOR

ON CHIEF ARM

CAT6

NOTES

1. RACK MAY NEED TO BE CUT DOWN BY 1 RU, OR

MORE, TO FIT INSIDE OF TEACHER STATIONS. REFER

TO DRAWING A705 FOR DETAIL OF TEACHER

STATION.

2. FLOOR BOX DEVICE PLATES WILL BE PROVIDED BY

E.C. AV CONTRACTOR SHALL COORDINATE

REQUIRED DEVICE PLATES FOR INSTALLATION OF

AV.DEVICES.

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SCREENING ROOM 103AV SIGNAL FLOW #1

AV103

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Scale:6" = 1'-0"

LECTERN CABLE CUBBY DETAIL (TYP. 2)

1

EXTRON POWER MODULE

EXTRON CABLE CUBBY 500

(BRUSHED ALUMINUM FINISH)

CABLE GROMMET

(INCL. W/ CABLE CUBBY)

NOTES:

1. COORDINATE AS REQUIRED FOR CUTTING TO ALLOW THE INSTALLATION OF

THE EXTRON CABLE CUBBY.

2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.

3. LECTERN HAS ONE CABLE CUBBY INSTALLED ON TOP AND ONE INSTALLED ON

SIDE FOR ADA

Page 21: AV00 - Rhode Island

YPbPr

Channel:

1080i

52-1

232-ATSC+1

USB

Air

CONTEMPORARY RESEARCH

ATSC-232 4

HDTV TUNER

HDMI HDMI 1

8G

EXTRON

60-1271-13

DTP HDMI 4K 230 RX

DTP 1B

DTP 7

C

HDMI

EXTRON

60-1583-01

DTP CROSSPOINT 82 4K

SCALING MATRIX SWITCHER

a

1

2

3

4 6

5

8GDTP 8

HDMI

RS232

NEC X981 UHD

98" LCD 4K MONITOR

POWER

12V

0.7A MAX

HDMI2A HDMI

A

TO NETWORK

SWITCH

8G

LEON VAULT ULTIMA #1

FRONT LEFT

LEON HZ ULTIMA SOUNDBAR

CENTER

TANNOY VX5.2

SPEAKER #3

SIDE LEFT

TANNOY VX5.2

SPEAKER #4

SIDE RIGHT

TANNOY VX5.2

SPEAKER #5

REAR LEFT

TANNOY VX5.2

SPEAKER #6

REAR RIGHT

SP

J-3

J-4

J-6

J-5

J-8

J-7

SP

AV RACK

SP

SP

SP

SP

J-2

SP

SP

FRONTLHDMI 1

FRONTR

SURRR

SURRL

BACKL

BACKR

CENTER

SUB

DOWNMIX

AUDIO L

AUDIO R

A

A

A

A

A

A

A

A

A

A

LEON ACS10UT

IN WALL SUBWOOFER

AUDIO L

AUDIO R

CRESTRON

HD-XSP SURROUND

SOUND PROCESSOR

J-1

J-9

AMPLIFIER1CHANNEL A

AMPLIFIER2

CHANNEL B

AMPLIFIER3

CHANNEL C

AMPLIFIER4

CHANNEL D

AMPLIFIER5

CHANNEL E

AMPLIFIER6CHANNEL F

BOSE PM8250N AMPLIFIER

AMPLIFIER7CHANNEL G

AMPLIFIERCHANNEL 1

8G

PROGRAM1

AUDIO L

AUDIO R

RACK PANEL

DOWNMIX

AUDIO L

AUDIO R

AUDIO L

AUDIO R

AUDIO L

AUDIO R

A

A

AUDIO L

AUDIO R

6

C

FROM SURROUND

PROCESSOR

C

TO DTP CROSSPOINT 42

INPUT 6

DM IN

AV NET

CUSTOM

MAAP

MODULES

A

A

A

J-1 J-2

A

8G

NOTES

1. OUTPUTS OF DTP CROSSPOINT ARE INDEPENDENTLY

SCALABLE.

2. HD-XSP SUPPORTS HD CONTENT ONLY. THE

CORRESPONDING HD OUTPUT WILL NEED TO BE SCALED

TO HD.

3. INPUT SOURCES ARE NATIVELY SET TO MULTICHANNEL.

THE TWO-CHANNEL DOWNMIX FROM HD-XSP WILL BE

USED IN MODES REQUIRING TWO CHANNEL OPERATION

AND TO FEED THE ASSISTIVE LISTENING OUTPUT PLATE.

4. 4K VIDEO PATH WILL FOLLOW FROM INSTRUCTOR

STATION TO THE DISPLAY.

CAT6

CAT6

FB-1

B

TO NETWORK

SWITCH

J-1

FB-2

D TO SOUNDBAR

DFROM AMPLIFIER SP

DM IN

AV NET

CUSTOM

MAAP

MODULES

LEON VAULT ULTIMA #2

FRONT RIGHT

LEON 1000W

AMPLIFIER

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SCREENING ROOM 103AV SIGNAL FLOW #2

AV103.1

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 22: AV00 - Rhode Island

PORT 1

PORT5

PORT4

4

1

POWER

RESET

AMBER : 10/100Mbps green : 1000Mpbs

3DIAG 1 2

PoE

65 87

2 3 4 5

PoE SWITCH76 8

10

99 10

PORT 2

CRESTRON

HD-XSP SURROUND

SOUND PROCESSOR

EXTRON 60-1583-01

DTP CROSSPOINT 82 4K

SCALING MATRIX SWITCHER #2

a

1

2

3

4 6

5

BOSE PM8250N AMPLIFIER

PORT6

CRESTRON CP3N CONTROLLER

COMA

SUBNET

LAN

AFROM FLOOR BOX CAT6

CAT6

CAT6

CRESTRON

TSW-1052-B-S

W/ TSW-1050-TTK-B-S

PORT 3BFROM FLOOR BOX CAT6

4

1

POWER

RESET

AMBER : 10/100Mbps green : 1000Mpbs

3DIAG 1 2

PoE

65 87

2 3 4 5

PoE SWITCH76 8

10

99 10

CISCO SF302-08P

NETWORK SWITCH W/ POE #1

PORT5 CAT6

EXTRON

60-1583-01

DTP CROSSPOINT 82 4K

SCALING MATRIX SWITCHER #1

a

1

2

3

4 6

5

PORT1 CAT6

OPPO BDP103

BLU-RAY PLAYER

RS232/DTP6 C

PORT7 CAT6

INSTRUCTOR STATION

RACK IN

INSTRUCTOR STATION

YPbPr

Channel:

1080i

52-1

232-ATSC+1

USB

Air

CONTEMPORARY RESEARCH

ATSC-232 4

HDTV TUNER

LAN 2

RS232/DTP 2

COMB

AV RACK

TO FLOOR BOX

CISCO SF302-08P

NETWORK SWITCH W/ POE #2

FB-1 J-1

FB-2

CAT6

C

C

CAT6

RS232/DTP 6

COMC C

MIDDLE ATLANTIC HHCM-1 CABLE MANAGER

CATV TUNER

CISCO NETWORK SWITCH - CONTROL

CRESTRON CP3N CONTROL PROCESSOR

1 RU BLANK

1 RU BLANK

ADA OUTPUT PLATE

1 RU BLANK

CONSULTANT ID PANEL

MIDDLE ATLANTIC MRK-24-26

RACK

EXTRON DTP CROSSPOINT 84 4K

SWITCHER

CRESTRON HD-XSP PROCESSOR

BOSE PM8500N

8 CHANNEL AMPLIFIER

1 RU BLANK

1 RU BLANK

BLANKS

SURGEX SX-1120-RT

1 RU BLANK

PORT7 CAT6

LIGHTING/SHADES CONTROLLER

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SCREENING ROOM 103CONTROL FLOW

AV103.2

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 23: AV00 - Rhode Island

THREE PERSON TABLE

NOTES:

1. SYSTEM FLOW DIAGRAM IS BASED UPON THE EXTRON TEAM WORK 400

SYSTEM.

2. AV CONTRACTOR TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM.

COORDINATE AS REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION

OF THE EXTRON CABLE CUBBY.

3. EQUIPMENT SHOULD BE SECURED TO THE UNDERSIDE OF THE TABLE SO THAT

IT DOES NOT FALL OFF.

4. CABLING BETWEEN THE HEADPHONE AMPLIFIER LOOP THROUGH AND THE

MACKIE REFERENCE MONITORS IS THROUGH A GROMMET IN THE TABLE.

RS232

CRESTRON MPC-M10

BUTTON CONTROLLER

COM A

PWR

J4

WALL BELOW MONITOR

C

P

MACKIE HRMK2

REFERENCE MONITOR #1

(TURNED SIDEWAYS BELOW

DISPLAY)

MACKIE HRMK2

REFERENCE MONITOR #2

(TURNED SIDEWAYS

BELOW DISPLAY)

A

A

FROM OUTPUT OF

OFE MIXER

A

A

FROM OUTPUT OF

OFE MIXER

SAMSUNG DM48E

48" LCD MONITOR

ROOM

101

ROOM

108

ROOM

110

COMPUTER

AUDIO

HDMI

EDIT SUITE 104

XLR 1

XLR 2

XLR 3

XLR 4

XLR 5

XLR 6

HDMI

AUDIO

A

A

A

A

A

A

VGA

J-5

TO SUITE 101

TO SUITE 101

TO SUITE 108

TO SUITE 108

TO SUITE 110

TO SUITE 110

HDMI

VGA

AUDIO

J-2

HDMI

VGA

A

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

EDIT ROOM 104 AVSIGNAL FLOW

AV104

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 24: AV00 - Rhode Island

HDMI 1

CONTACT 1

TALLY OUT 1

HDMI 2

CONTACT 2

TALLY OUT 2

HDMI 3

CONTACT 3

TALLY OUT 3

HDMI 4

CONTACT 4

TALLY OUT 4

R

EXTRON CABLE

CUBBY 700

OFE LAPTOP

EXTRON SW4

HDMI SWITCHER

OFE LAPTOP

OFE LAPTOP

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

HDMI / CONTROL

HDMI / CONTROL

J-1x J-2x

SAMSUNG DM48E

48" LCD MONITOR

HDMI 1

HDMI / CONTROL

HDMI / CONTROL

RS232

UNDERSIDE OF TABLE IN

ACCESSIBLE TABLE PEDESTAL

OR ATTACHED TO UNDERSIDE

OF TABLE TOP

TOP OF TABLE

HDMI / CONTROL

A

FROM H/PHONE

AMP 1

ROLLS HA43 PRO

HEADPHONE AMP #1

AUDIOA

E

FROM MONITOR

AUDIO OUT

H/PHONE1

H/PHONE2

H/PHONE3

A

TO CABLE

CUBBY

B

TO CABLE

CUBBY

C

TO CABLE

CUBBY

A

A

A

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

B

FROM H/PHONE

AMP 2

C

FROM H/PHONE

AMP 3

AUDIO L/R

HDMI1

RS232

HDMI

C

NOTES:

1. THE ABOVE SYSTEM IS TYPICAL FOR TWO (2) STATIONS IN ROOM 106

2. SYSTEM FLOW DIAGRAM IS BASED UPON THE EXTRON TEAM WORK 400

SYSTEM.

3. AV CONTRACTOR TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM.

COORDINATE AS REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION

OF THE EXTRON CABLE CUBBY.

OFE LAPTOP

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

HDMI / CONTROL

D

FROM H/PHONE

AMP 4

H/PHONE4 D

TO CABLE

CUBBY

A

E

TO HEADPHONE

AMP

A

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

SPEAKING-WRITINGLAB 106 AV SIGNAL

FLOW

AV105

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

NOTES:

1. AVC TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM. COORDINATE AS

REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION OF THE EXTRON

CABLE CUBBY.

2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.

Scale:6" = 1'-0"

CABLE CUBBY DETAIL (TYP. 2)

1

EXTRON POWER MODULE

(INCL. W/ CABLE CUBBY)

EXTRON CABLE CUBBY 700

CABLE GROMMET

(INCL. W/ CABLE CUBBY)

EXTRON 70-098-11

TWO STEREO 3.5 MINI JACKS

Page 25: AV00 - Rhode Island

HDMI 1

CONTACT 1

TALLY OUT 1

HDMI 2

CONTACT 2

TALLY OUT 2

HDMI 3

CONTACT 3

TALLY OUT 3

HDMI 4

CONTACT 4

TALLY OUT 4

R

EXTRON CABLE

CUBBY 1400

OFE LAPTOP

EXTRON SW4

HDMI SWITCHER

OFE LAPTOP

OFE LAPTOP

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

HDMI / CONTROL

HDMI / CONTROL

J-1A J-2A

SAMSUNG DM48E

48" LCD MONITOR

HDMI 1

HDMI / CONTROL

HDMI / CONTROL

MAINS

UNDERSIDE OF TABLE IN

ACCESSIBLE TABLE PEDESTAL

OR ATTACHED TO UNDERSIDE

OF TABLE TOP

TOP OF TABLE

HDMI / CONTROL

1

FROM H/PHONE

AMP 1

ROLLS HA43 PRO

HEADPHONE AMP #1

AUDIOA

A

FROM MONITOR

AUDIO OUT

H/PHONE1

H/PHONE2

H/PHONE3

1

TO CABLE

CUBBY

2

TO CABLE

CUBBY

3

TO CABLE

CUBBY

A

A

A

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

2

FROM H/PHONE

AMP 2

3

FROM H/PHONE

AMP 3

AUDIO L/R

HDMI1

RS232

HDMI

C

NOTES:

1. THE ABOVE SYSTEM IS TYPICAL FOR TWO (2) STATIONS IN ROOM 106

2. SYSTEM FLOW DIAGRAM IS BASED UPON THE EXTRON TEAM WORK 400

SYSTEM.

3. AV CONTRACTOR TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM.

COORDINATE AS REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION

OF THE EXTRON CABLE CUBBY.

OFE LAPTOP

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

HDMI / CONTROL

3

FROM H/PHONE

AMP 4

H/PHONE4 4

TO CABLE

CUBBY

A

ROOM

101

ROOM

104

ROOM

110

EDIT SUITE 106

XLR 1

XLR 2

XLR 3

XLR 4

XLR 5

XLR 6

A

A

A

A

A

A

J-3A

TO SUITE 101

TO SUITE 101

TO SUITE 104

TO SUITE 104

TO SUITE 110

TO SUITE 110

WALL BELOW TV

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

COLLABORTE & EDITSUITE 108

AV106

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

NOTES:

1. AVC TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM. COORDINATE AS

REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION OF THE EXTRON

CABLE CUBBY.

2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.

Scale:6" = 1'-0"

CABLE CUBBY DETAIL

1

EXTRON POWER MODULE

(INCL. W/ CABLE CUBBY)

EXTRON CABLE CUBBY

1400

CABLE GROMMET

(INCL. W/ CABLE CUBBY)

EXTRON AAP TWO STEREO

3.5 MINI JACKS

TYP 2

EXTRON AAP 1 SPACE

BLANK

Page 26: AV00 - Rhode Island

HDMI 1

CONTACT 1

TALLY OUT 1

HDMI 2

CONTACT 2

TALLY OUT 2

HDMI 3

CONTACT 3

TALLY OUT 3

HDMI 4

CONTACT 4

TALLY OUT 4

R

EXTRON CABLE

CUBBY 600S

60-525-01

OFE LAPTOP

EXTRON SW4

HDMI SWITCHER

OFE LAPTOP

OFE LAPTOP

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

HDMI / CONTROL

HDMI / CONTROL

J-1B J-2B

SAMSUNG DM48E

48" LCD MONITOR

HDMI 1

HDMI / CONTROL

HDMI / CONTROL

MAINS

UNDERSIDE OF TABLE IN

ACCESSIBLE TABLE PEDESTAL

OR ATTACHED TO UNDERSIDE

OF TABLE TOP

THREE PERSON TABLE

HDMI / CONTROL

1

FROM H/PHONE

AMP 1

ROLLS HA43 PRO

HEADPHONE AMP #1

AUDIOA

A

FROM MONITOR

AUDIO OUT

H/PHONE1

H/PHONE2

H/PHONE3

1

TO CABLE

CUBBY

2

TO CABLE

CUBBY

3

TO CABLE

CUBBY

A

A

A

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

2

FROM H/PHONE

AMP 2

3

FROM H/PHONE

AMP 3

HDMI1

RS232

HDMI

C

NOTES:

1. THE ABOVE SYSTEM IS TYPICAL FOR TWO (2) STATIONS IN ROOM 106

2. SYSTEM FLOW DIAGRAM IS BASED UPON THE EXTRON TEAM WORK 400

SYSTEM.

3. AV CONTRACTOR TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM.

COORDINATE AS REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION

OF THE EXTRON CABLE CUBBY.

OFE LAPTOP

PULL UP HDMI

CABLE WITH SHOW

ME BUTTON

HDMI / CONTROL

3

FROM H/PHONE

AMP 4

H/PHONE4 4

TO CABLE

CUBBY

A

ROOM

101

ROOM

104

ROOM

108

EDIT SUITE 110

XLR 1

XLR 2

XLR 3

XLR 4

XLR 5

XLR 6

A

A

A

A

A

A

J-3B

TO SUITE 101

TO SUITE 101

TO SUITE 104

TO SUITE 104

TO SUITE 108

TO SUITE 108

WALL BELOW TV

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

COLLABORTE & EDITSUITE 110

AV107

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

NOTES:

1. AVC TO PROVIDE FOR TEAM SHARE COLLABORATION SYSTEM. COORDINATE AS

REQUIRED FOR TABLE CUTTING TO ALLOW THE INSTALLATION OF THE EXTRON

CABLE CUBBY.

2. PLUG UNUSED HOLES IN CABLE PASS THROUGH WITH GROMMET PLUGS.

Scale:##########

CABLE CUBBY DETAIL

1

EXTRON POWER MODULE

(INCL. W/ CABLE CUBBY)

EXTRON CABLE CUBBY

1400

CABLE GROMMET

(INCL. W/ CABLE CUBBY)

EXTRON AAP

TWO STEREO 3.5 MINI JACKS

TYP 2

EXTRON AAP

1 SPACE BLANK

Page 27: AV00 - Rhode Island

EPSON GW5650

4500 LUMENS PROJECTOR

CRESTRON

DM-RMC-SCALER -C

DM OUT 1

70V

HDMI 1

DM 6

8G

C

HDMI

CB-1

TANNOY CVS6

CEILING SPEAKERS W/

TAP @ 15W

TYP. 8

AV-2

SAMSUNG DM48

48" LCD MONITOR #1

ROLLS HA43 PRO

HEADPHONE AMP #1

AUDIO L/R

H/PHONE1

H/PHONE2

H/PHONE3

A

A

A

CRESTRON DM-TX-201-C-2G

DM TRANSMITTER #1

C

HDMI

A

AV INPUT PLATE

(1) CRESTRON MP-WP152

(1) CRESTRON MP-WP130

8G

RS232

HDMI 1

CATVRF

LANCAT6

H/PHONE4A

J-3xJ-2x

PORT 1 PORT5

4

1

POWER

RESET

AMBER : 10/100Mbps green : 1000Mpbs

3DIAG 1 2

PoE

65 87

2 3 4 5

PoE SWITCH76 8

10

99 10

PORT 2

PORT 3

CISCO SF302-08P

NETWORK SWITCH W/ POE

PORT 4

MIC 1M

CRESTRON DMPS3-200-C

DIGITAL PRESENTATION PROCESSOR

ANTENNA A

MIC

ANTENNA B

SENNHEISER 300 RECEIVER W/ CARDIOID

HANDHELD AND CARDIOD LAVALIER

HEADPHONE PLATE

VGAVGA 1

AUDIO

A

CRESTRON MPC-M10

BUTTON CONTROLLER #1

COM A

PWR

AUIDIO L/R

A LINE

LOOP OUT

PERIMETER

LOOP

(UNDER

FINISHED FLOOR)

LISTEN

TECHNOLOGIES

ILD500 AMPLIFIER

PROGRAM

AUDIO L

AUDIO R A

SP

RELAY1/2

DA-LITE LOW

VOLTAGE

PROJECTION

SCREEN WALL

SWITCH

J-4

DA-LITE 76.25" X 122" CEILING RECESSED

PROJECTION SCREEN

YPbPr

Channel:

1080i

52-1

232-ATSC+1

USB

Air

CONTEMPORARY RESEARCH

ATSC-232 4

HDTV TUNER

HDMI

C

SP

J-1

COMA

A

TO CONTEMPORARY

RESEARCH TUNER

A

FROM DMPS3-200-C

COM A

C

C

AV RACK

(IN STORAGE CLOSET)

MONITOR LOCATION

(TYPICAL OF 3)

LAN

J-2xJ-1x

P

CAT6

AV-1x

B TO NETWORK SWITCH

AT MONITOR LOCATION

TO CLIENT NETWORK

TO CATV (FUTURE)

CRESTRON MPC-B10

BUTTON CONTROLLER

CAT6 LAN

B

FROM CRESTRON MPC-M10

BUTTON CONTROLLER #1

CAT6

CAT6

CAT6

CAT6

J-1

AV-1A

B

FROM CRESTRON MPC-M10

BUTTON CONTROLLER #2

B

FROM CRESTRON MPC-M10

BUTTON CONTROLLER #3

AV-1B

AV-1C

SKM300 G3 HANDHELD W/ E835

SK300 G3 BODYPACK W/ ME4

MIDDLE ATLANTIC HHCM-1 CABLE MANAGER

CATV TUNER

CISCO NETWORK SWITCH - CONTROL

1 RU BLANK

LISTEN TECHNOLOGIES ILD5000

1 RU BLANK

CONSULTANT ID PANEL

MIDDLE ATLANTIC MRK-24-26

CRESTRON DMPS3-200-C

WIRELESS MICROPHONE

1 RU BLANK

BLANK

3RU DRAWER

1 RU BLANK

2 RU BLANK

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

LIVING ROOM AVSIGNAL FLOWS

AV108

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 28: AV00 - Rhode Island

CRESTRON

DM-RMC-SCALER -C

C

HDMI

PRIMEVIEW PRV49SNG

49" LCD MONITOR #1

HDMI 1

RS232

CRESTRON MPC-B10

BUTTON CONTROLLER

IN TECH DIRECTORS

OFFICE

AUDIO L

AUDIO R

HOLOSONICS AS-26I-W

SPOTLIGHT SPEAKER

P

A

A

DVI

AV-4

CB-1

RS232

PRIMEVIEW PRV49SNG

49" LCD MONITOR #2

HDMI 1

RS232

DVI

RS232

PRIMEVIEW PRV49SNG

49" LCD MONITOR #3

HDMI 1

RS232

DVI

RS232

PRIMEVIEW PRV49SNG

49" LCD MONITOR #4

HDMI 1

RS232

DVI

RS232

C

HDMI

C

HDMI

C

HDMI

P

CAT6

DM-9G

J-6

POWER SUPPLY AT VIDEO

WALL

J-5

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

DIGITAL SIGNAGE AVSIGNAL FLOWS

AV109

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

Page 29: AV00 - Rhode Island

SIDE

9"

B

C

6 1/4"

12"

A

FRONT

D-5

AVA

D-1

AVA

D-2

AVA

D-3

AVA

D-4

AVA

D-6

AVA

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

MIDDLE ATLANTIC MRK-2127

1" = 1'-0" AVCAVC

3 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

PROJECTOR MOUNTING

2" = 1'0" AVCAVC

2 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

DALITE TENSIONED ADVANTAGE ELECTROL

3/4" = 1'-0" AVCAVC

2

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

TANNOY CVS6 CEILING SPEAKERS

1-1/2" = 1'-0" AVCAVC

20 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

RECESSED 48" LED MONITOR

1" = 1'-0" AVCAVC

1 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

48" LED MONITOR

1" = 1'-0" AVCAVC

1

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

AV DETAILS

AVA

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

2'-3 1/2"

2'-0

1

/4

"

2'-0 1/4"

4'-0

1

/2

"

4'-0

1

/2

"

2'-3 5/8"

RE

FE

R T

O A

V C

ON

DU

IT

R

IS

ER

S F

OR

M

OU

NT

IN

G H

EIG

HT

S

2'-3

5

/8

"

3'-7 3/8"

7 1/2"

2"

2"

2'-3

3

/8

"

RE

FE

R T

O A

V C

ON

DU

IT

R

IS

ER

S F

OR

M

OU

NT

IN

G H

EIG

HT

S

3'-7 3/8"

CHIEF CMS012W 12" WHITE

EXTENSION COLUMN BY AVC

CHIEF WHITE PROJECTOR MOUNT

BY AVC

PROJECTOR BY AVC

CEILING TILE

BUILDING STRUCTURE BY

GC

SIGNAL CABLES

UNISTRUT TO ATTACH TO

STRUCTURE ABOVE BY

THREADED ROD BY GC

CHIEF CMA110 8" CEILING

PLATE BY AVC

THREADED ROD TO ATTACH

TO UNISTRUT BY GC

10"

TO

B

E D

ET

ER

MIN

ED

IN

F

IE

LD

CEILING POWER

*TO BE LOCATED AS CLOSE TO

PIPE LOCATION AS POSSIBLE

POWER CABLE

TO SCREEN

IMAGE HEIGHT [A] IMAGE WIDTH [B] CASE LENGTH [C] QUANTITY BLACK DROP

60"

96" 114" 2 12

STRUCTURE ABOVE BY GC

SECURE SPEAKER TO STRUCTURE

ABOVE

CEILING TILE BY GC

11"

10

1

/4

"

6 5

/8

"

8"

3"

9 1/8"

3/4" THREADED ROD TO

STRUCTURE ABOVE BY GC

Page 30: AV00 - Rhode Island

COMPUTER

12

12

12

AUDIO

HDMI

12

12

12

12 5/8"

9 1/8"

18

5

/8

"

15

1

/8

"

7 1/8"

13

1

/8

"

D-11

AVB

D-7

AVB

D-8

AVB

D-9

AVB

D-10

AVB

D-12

AVB

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

5 GANG AV PLATE

6" = 1'-0" AVCAVC

4 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

LOWELL LDTR

1" = 1'-0" AVCAVC

1 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

DALITE COSMOPOLITAN ELECTROL

3/4" = 1'-0" AVCAVC

1

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

CHIEF NW2 WALL MOUNTED RACK

1-1/2" = 1'-0" AVCAVC

1 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

TANNOY VX 5.2

3" = 1'-0" AVCAVC

4 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

LEON ACS10UT SUBWOOFER

1-1/2" = 1'-0" AVCAVC

1

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

AV DETAILS

AVB

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

2'-1

7

/8

"

1'-6 1/8"

1'-6

1

/8

"

1'-6

3

/8

"

1'-5

7

/8

"

1'-6 1/8"

1'-3

7

/8

"

11 3/4"

5 1/4"

1'-10 1/8"

1'-6

3

/8

"

122"

76

.2

5"

143.5"

4 5

/8

"

5 3

/4

"

ROOMS: 101 & 104

ROOMS: 108 & 110

NEUTRIK COMBO

#NCJ9FI-S

(TYP)

WIRING DIAGRAM

PLATE TYPE:ALUMINUM

ENGRAVING COLOR: WHITE

PLATE COLOR: BLACK

BASE OF SUBWOOFER IS REMOVED FOR INSTALLATION

Page 31: AV00 - Rhode Island

FRONT VIEW RIGHT SIDE VIEW

TOP VIEW

0.36 MINIMUM TABLE THICKNESS

2.86 MAXIMUM TABLE THICKNESS

6.13

6.13

4.09

9.63 4.83

DETAIL A

SIDE VIEW FRONT VIEW

TOP VIEW

SEE DETAIL A

7.17

10.32

13.82

8.49

0.44

6.41

5.73

6.67

9.82

BOTTOM VIEW

D-17

AVC

D-13

AVC

D-14

AVC

D-15

AVC

D-16

AVC

D-18

AVC

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

CRESTRON MPC-B/M CONTROLLERS (TYPICAL)

NTS AVCAVC

6 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

SHARP PN-R903 WITH LEON SOUNDBAR

3/4" = 1'-0" AVCAVC

1 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

LEON VAULT IN-WALL SPEAKERS

3" = 1'-0" AVCAVC

2

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

LEON SOUNDBAR

3" = 1'-0" AVCAVC

1 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

EXTRON CABLE CUBBY 500

3" = 1'-0" AVCAVC

5 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

EXTRON CABLE CUBBY 1400

3" = 1'-0" AVCAVC

10

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

AV DETAILS

AVC

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com

PREMIER AM300

MOUNT

PLYWOOD

BLOCKING BY GC

WALL STUDS BY GC

CHIEF PAC521P

PROVIDED BY GC

INSTALLED BY GC

MONITOR BY AVC

4"

9 1/4"

4 3/4"

LENGTH OF SOUND BAR IS THE WIDTH OF NICHE. VERIFY LENGTH IN FIELD.

Page 32: AV00 - Rhode Island

D-22

AVD

D-18

AVD

D19

AVD

D-20

AVD

D-21

AVD

D-23

AVD

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

MIDDLE ATLANTIC SRSR-2-X RACK

NTS AVCAVC

3 TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:AVC

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:AVC

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

TITLE:

SCALE:

QUANTITY:

INSTALLED BY:SUPPLIED BY:

DATE:

FILE:

DATENO BY DESCRIPTION

C COPYRIGHT 2012DURKEE BROWN VIVEIROS WERENFELS ARCHITECTSUNAUTHORIZED USE IS PROHIBITED.

JOB NO.:

DRAWN BY:

AV BID SET

12.16.15

1129

Harrington School of Communication & Media

University of Rhode IslandKingston, RI

MBH

AV DETAILS

AVD

ACT Associates, LLC922F Stafford RoadStorrs, CT 06268tel. 860.429.5938www.act-associates.com