PROJECT DETAILS
4 Star Boutique Hotel
90 Guest Keys
Restaurant
Bar/Lounge
Cinema (6 screens)
Retail
South East Perspective
8/3/2019 Arch 496 Sp11 Trujillo.N
3/18
Proposed Design - View from Beav
DESIGN CONCEPT
8/3/2019 Arch 496 Sp11 Trujillo.N
4/18
Features:-Underground Parking structure for 100 spaces
-70 ft high atrium space
-Site grade (115) caused a retaining wall to be placed on Beaver Ave
Hotel Entrance (8 ft high from road)
Advantage: Noise from Beaver Ave controlledDisadvantage: more expensive for excavation
HOTEL
8/3/2019 Arch 496 Sp11 Trujillo.N
5/18
Atrium:
Advantages:
-Natural Light provided toHotel Lobby and Hall
-Ventilation
HOTEL
8/3/2019 Arch 496 Sp11 Trujillo.N
6/18
Suites Views
Atrium
HOTEL
8/3/2019 Arch 496 Sp11 Trujillo.N
7/18
HOTEL
Features:
- Walk-in closet
- Jacuzzi tub
- Two sink vanity
Suite Layout
8/3/2019 Arch 496 Sp11 Trujillo.N
8/18
King Room
Double Queen Room
HOTEL
8/3/2019 Arch 496 Sp11 Trujillo.N
9/18
Bar (1156 sq ft)
Brazilian Koa (Wood Flooring)
Restaurant/Kitchen (2955 sq
RESTAURANT/BAR
8/3/2019 Arch 496 Sp11 Trujillo.N
10/18
3 Retail Spaces available1991 sq. ft each
RETAIL
8/3/2019 Arch 496 Sp11 Trujillo.N
11/18
Projection Room(802 sq ft)
225 Seat Cinema- Stadium Sea
NE Perspective
Design
Inspiration
CINEMA
8/3/2019 Arch 496 Sp11 Trujillo.N
12/18
CINEMA - Lobby
8/3/2019 Arch 496 Sp11 Trujillo.N
13/18
Height Restrictions (Local Zoning & IBC)90ft restriction
Parking (Local Zoning) 100 Spaces, 10 ADA
Set backs (Local Zoning) 25ft
Egress (IBC)
Fire Protection (IBC)
Accessibility (ADA)
IBC Building Occupancy Type Mixed Use A-1 (Restaurant)
A-2 (Cinema)
M (Mercantile)
R-1 (Hotel)
U (Parking)
Township of State College C-1 (General Commercial District)
Building Height, from midpoint of the site to
mechanical space: 80 ft
BUILDING CODES
8/3/2019 Arch 496 Sp11 Trujillo.N
14/18
Egress (IBC)
Maximum travel distance shall not exceed
200ft un sprinkled and 250ft sprinkled.
Width of exit passageway is 66 in.
Fire Protection (IBC)
A-1 (3 hour rating)
A-2 (3 hour rating) M (3 hour rating)
R-1 (3 hour rating)
U (3 hour rating)
Stairwells with Automatic Sprinklers (reduceto 1 hour rating)
Accessibility (ADA) ACCESSIBLE TRANSIENT LODGING
4 Accessible Rooms
Corridor Width
Minimum corridor width or isles is 36" w
clear at any one point. Corridor or isles f
wheelchair and passing person is 4
BUILDING CODES
8/3/2019 Arch 496 Sp11 Trujillo.N
15/18
Reinforced Concrete Columns (20in x 20in)
and Beams (12x24)
Spacing along hotel hallway on opposite wall
as plumbing
Typical Hotel bay (16ft x 28ft)
Cinema Floor: Two-way action reinforced
concrete with No. 10 rebar at 6in oc (16in) 50 ft span
STRUCTURAL SYSTEM
8/3/2019 Arch 496 Sp11 Trujillo.N
16/18
Restaurant, Cinema, Retail, Parking Cinema %2 screening rooms (275 seats) 2517 sq ft2 screening rooms (140 seats) 1580 sq ft
2 screening rooms (110 seats) 1320 sq ft
Projection Rooms (Floor3)
Projection Rooms(Floor5)
Entrance lobby
Box Office(Floor 2)
General Circulation(Floor 2)
General Circulation(Floor 3)
Concessions(Floor 2)
Coming Attractions Kiosk/ Movie Time Clock(Floor 3)
ATM Machines(Floor 2)
Video game area(Floor 3)
Toilets (as required by building code)(Floor 3)
Storage(Floor 4)
Managers Office(Floor 4)
Event Room(Floor 4)Total
Retail Space %Difference
1 -0.42%
2 -0.42%
3 -0.42%
Total -0.42%
Parking
100 spaces (10 ADA spots) 28536 sq ft
Restaurant Space %Difference
Restaurant (90 seats) 0.13%
Kitchen/Storage 0.29%
Bar/Lounge 0.52%
Total 0.27%
AREA PROGRAM
8/3/2019 Arch 496 Sp11 Trujillo.N
17/18
Back of House %DifferenAdministration
Front Office / Communications
/ Hotel Operations45.50%
Hotel General Manager Office
Suite1.67%
Luggage Storage 1.00%
Guest Room Support
Clean Linen / Housekeeping
Storage 29.50%General Hotel Storage 106.00%
Engineering Offices -0.33%
Engineering Shop 7.00%
Engineering Storage 7.00%
Boutique Hotel (90 guest keys) %Difference
Double Queen Room (42 guest keys) -0.14%King Room (36 guest keys) -0.50%
Suite (12 guest keys) 2.56%
Total 0.37%
Public Areas %Difference
Meeting Rooms
Meeting Room (2) 39.50%Board Room 53.14%
Meeting Room Support 0.67%
Retail/Commercial/Food and
Beverage (Lobby News/
Convenience Shop)
31.60%
Hotel Recreation (Exercise Room) 280.83%
TOTAL (GSF): 155, 077 sq ft TOTAL (NSF):116,538 s
Hotel
AREA PROGRAM
8/3/2019 Arch 496 Sp11 Trujillo.N
18/18
Water consumption can be reduced Energy consumption is lowered
enhanced insulation,
addressing undesirable solar heat loads
high efficiency HVAC systems
onsite solar electric or hot water systems
Regional materials Indoor environmental quality
low-emitting materials and finishes
ventilation
Daylight (100% of rooms have day lighting)
views
SUSTAINABILITYCONSIDERATIONS