40
Applied Systems Pricelist ALL SEASONS PERFECT C MFORT 2013

Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

Embed Size (px)

Citation preview

Page 1: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

Applied Systems

Pricelist ■■

All SeASonS Perfect c mfort

2013

Page 2: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

2

Type Refrigerant Compressor Material Capacity PageAir cooled chiller inverter r-410A Swing eWAQ-A 5-13 kW 3

Air cooled heat pump inverter r-410A Swing eWYQ-A 6-14 kW 4

Air cooled chiller Inverter r-410A Scroll eWAQ-BAW 17-75 kW 5

Air cooled heat pump Inverter r-410A Scroll eWYQ-BAW 17-75 kW 5

Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6

Air cooled heat pump r-407c Scroll eUWY-KBZW 12-54 kW 7

Air cooled chiller r-410A Scroll eWAQ-DAYn 80-254 kW 8

Air cooled heat pump r-410A Scroll eWYQ-DAYn 88-281 kW 9

Water cooled chiller r-407c Scroll eWWP-KBW1n 13-65 kW 10

Water cooled chiller r-407c Scroll eWWP-KAW1m 86-195 kW 11

condenserless chiller r-407c Scroll eWlP-KBW1n 12-62 kW 12

condensing unit heat pump Inverter r-410A Scroll erQ 11-28 kW 13

Hydronic Kit eKBt / eHmc 14

rooftop heat pump r-410A Scroll UAtYQ-cY1 27-73 kW 14

rooftop heat pump r-407c Scroll UAtYP-AY1 79-110 kW 14

fan coil

low eSP duct fWe-c 2,1 - 10 kW 15

medium eSP duct fWB-B 2,6 - 11 kW 16

High eSP flexi duct fWD 3,9 - 18 kW 17

cassette 600x600 fWf-c 2,5 - 4,5 kW 18

cassette 600x600 fWf-B 1,7 - 4 kW 18

cassette 900x900 fWc-B 5 - 7,2 kW 18

Wall mounted fWt-c 2,3 - 5,3 kW 19

floor standing fWV 1,5 - 8 kW 22

flexi fWl 1,5 - 8 kW 23

flexi concealed fWm 1,5 - 8 kW 24

PlUG and PlAY VrV® connection AHU 26

Air cooler 32

Air Handling Unit 32

Dry cooler & condenser 32

cooling tower 32

compressor Service Screw/recip 33

overview: Air cooled chiller portfolio 34

overview: Portfolio Water cooled and condenserless units 36

large chillers options and accessories summary 36

measuring conditions 38

commercial terms and conditions 39

Table of contents

→ noteSThe pricelist is valid from 1. April 2013. All prior pricelists are not valid anymore. All prices are list prices in Euro and excl. VAT. The Daikin Commercial Terms and Conditions apply (see last page or http://www.daikin-ce.com). We reserve the right for printing errors and model changes.

Page 3: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

3

Unit size (1 phase) EWAQ005ADVP EWAQ006ADVP EWAQ007ADVP

Price HUf 793.000,– 868.400,– 963.100,–cooling capacity kW 5,2 6 7,1eer 2,75 2,55 2,41eSeer 3,75 3,83 3,87Sound power level dB(A) 62 62 63

Options

OP10 evaporator heater tape HUf 118.500,– 118.500,– 118.500,–

Unit size (1 phase) EWAQ009ACV3P EWAQ010ACV3P EWAQ011ACV3P

Price HUf 1.098.700,– 1.163.600,– 1.249.700,–cooling capacity kW 8,5 9,5 11eer 3,11 2,98 2,88eSeer 4,57 4,52 4,46Sound power level dB(A) 64 64 64

OptionsOP10 evaporator heater tape HUf 131.100,– 131.100,– 131.100,–SOPHP high eSP pump (up to 90 kPa) HUf on request on request on requestEKRP1HBA digital I/0 PcB HUf 36.600,– 36.600,– 36.600,–

Unit size (3 phase) EWAQ009ACW1P EWAQ011ACW1P EWAQ013ACW1P

Price HUf 1.146.400,– 1.260.400,– 1.335.800,–cooling capacity kW 9 11 13eer 3,04 2,88 2,59eSeer 4,68 4,63 4,52Sound power level dB(A) 64 64 66

OptionsOP10 evaporator heater tape HUf 131.100,– 131.100,– 131.100,–SOPHP high eSP pump (up to 90 kPa) HUf on request on request on requestEKRP1HBA digital I/0 PcB HUf 36.600,– 36.600,– 36.600,–

AIr cooleD cHIller InVerter

→ eWAQ-AHigh ESEER thanks to inverter technology, integrated hydronics.

EWAQ-A

Page 4: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

4

Unit size (1 phase) EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP

Price HUf 915.700,– 988.900,– 1.056.600,–cooling capacity kW 5,2 6 7,1eer 2,75 2,55 2,41Heating capacity kW 5,65 6,35 7,75coP 2,87 2,83 2,74Sound power level dB(A) 62 62 63

Options

OP10 evaporator heater tape HUf 118.500,– 118.500,– 118.500,–

Unit size (1 phase) EWYQ009ACV3P EWYQ010ACV3P EWYQ011ACV3P

Price HUf 1.264.700,– 1.331.500,– 1.411.100,–cooling capacity kW 8,5 9,5 11eer 3,11 2,98 2,88eSeer 4,57 4,52 4,46Heating capacity kW 10 11,5 13coP 3,44 3,4 3,37Sound power level dB(A) 64 64 64

Options

OP10 evaporator heater tape HUf 131.100,– 131.100,– 131.100,–SOPHP high eSP pump (up to 90 kPa) HUf on request on request on requestEKRP1HBA digital I/0 PcB HUf 36.600,– 36.600,– 36.600,–

Unit size (3 phase) EWYQ009ACW1P EWYQ011ACW1P EWYQ013ACW1P

Price HUf 1.314.300,– 1.426.200,– 1.508.300,–cooling capacity kW 9 11 13eer 3,04 2,88 2,59eSeer 4,68 4,63 4,52Heating capacity kW 11 12,5 14coP 3,41 3,38 3,34Sound power level dB(A) 64 64 66

Options

OP10 evaporator heater tape HUf 131.100,– 131.100,– 131.100,–SOPHP high eSP pump (up to 90 kPa) HUf on request on request on requestEKRP1HBA digital I/0 PcB HUf 36.600,– 36.600,– 36.600,–

AIr cooleD HeAt PUmP InVerter

→ eWYQ-AWide operation range - ambient temperature in heating down to -15°C.

EWYQ-A

Page 5: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

5

Unit size EWAQ016BAW EWAQ021BAW EWAQ025BAW EWAQ032BAW EWAQ040BAW EWAQ050BAW EWAQ064BAW

Price HUf 1.906.300,– 2.244.800,– 2.531.600,– 2.920.800,– 3.864.200,– 4.304.800,– 4.970.800,–cooling capacity (nominal) kW 16,8 21,0 25,2 31,5 42,0 50,4 63,0eSeer 4,75 4,65 4,45 4 4,6 4,4 3,95Sound power level dB(A) 78 78 78 80 81 81 83

Options

OP10 evaporator electric heater HUf 153.800,– 153.800,– 153.800,– 153.800,– 180.100,– 180.100,– 180.100,–OPSP one centrifugal pump (low lift) HUf 170.800,– 170.800,– 170.800,– 208.500,– 208.500,– 208.500,– 208.500,–OPHP one centrifugal pump (high lift) HUf 250.600,– 250.600,– 250.600,– 250.600,– 317.900,– 317.900,– 317.900,–OPZL low leaving water operation down to -10 °c HUf 113.800,– 113.800,– 113.800,– 113.800,– 144.300,– 144.300,– 144.300,–

Kit

EKRP1AHT Demand PcB remote: on/off, cool/heat, thermo on/off HUf 40.300,– 40.300,– 40.300,– 40.300,– 80.700,– 80.700,– 80.600,–

EKRUAHT Additional remote user interface HUf 60.500,– 60.500,– 60.500,– 60.600,– 60.600,– 60.600,– 60.600,–BHGP26A1 Digital pressure gauges HUf 148.500,– 148.500,– 148.500,– 148.500,– 296.900,– 296.900,– 296.900,–

DTA104A62 external adaptor for: Demand and low noise control HUf 133.000,– 133.000,– 133.000,– 133.000,– 266.000,– 266.000,– 266.000,–

RTD-W modbus interface HUf 109.200,– 109.200,– 109.200,– 109.200,– 109.200,– 109.200,– 109.200,–

Unit size EWYQ016BAW EWYQ021BAW EWYQ025BAW EWYQ032BAW EWYQ040BAW EWYQ050BAW EWYQ064BAW

Price HUf 2.192.100,– 2.582.000,– 2.912.000,– 3.359.600,– 4.443.500,– 4.950.300,– 5.716.900,–cooling capacity (nominal) kW 16,8 21,0 25,2 31,5 42,0 50,4 63,0eSeer 4,75 4,65 4,45 4 4,6 4,4 3,95Heating capacity (nominal) kW 16,8 21,0 25,2 31,5 42,0 50,4 63,0coP 3,05 2,96 2,84 3 2,96 2,83 3Sound power level dB(A) 78 78 80 80 81 83 83

Options

OP10 evaporator electric heater HUf 153.800,– 153.800,– 153.800,– 153.800,– 180.100,– 180.100,– 180.100,–OPSP one centrifugal pump (low lift) HUf 170.800,– 170.800,– 170.800,– 208.500,– 208.500,– 208.500,– 208.500,–OPHP one centrifugal pump (high lift) HUf 250.600,– 250.600,– 250.600,– 250.600,– 317.900,– 317.900,– 317.900,–OPZL low leaving water operation down to -10 °c HUf 113.800,– 113.800,– 113.800,– 113.800,– 144.300,– 144.300,– 144.300,–

Kit

EKRP1AHT Demand PcB remote: on/off, cool/heat, thermo on/off HUf 40.300,– 40.300,– 40.300,– 40.300,– 80.700,– 80.700,– 80.600,–

EKRUAHT Additional remote user interface HUf 60.500,– 60.500,– 60.500,– 60.600,– 60.600,– 60.600,– 60.600,–BHGP26A1 Digital pressure gauges HUf 148.500,– 148.500,– 148.500,– 148.500,– 296.900,– 296.900,– 296.900,–

DTA104A62 external adaptor for: Demand and low noise control HUf 133.000,– 133.000,– 133.000,– 133.000,– 266.000,– 266.000,– 266.000,–

RTD-W modbus interface HUf 109.200,– 109.200,– 109.200,– 109.200,– 109.200,– 109.200,– 109.200,–

AIr cooleD cHIller InVerter

→ eWAQ-BAWHigh efficiency with leader-of-class ESEER.

No buffer tank required for standard applications.

AIr cooleD HeAt PUmP InVerter

→ eWYQ-BAW Wide operation range - ambient temperature in heating down to -15°C.

EWAQ-BAW, EWYQ-BAW

Page 6: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

6

AIr cooleD cHIller

→ eUWA-KBZW

Unit size EUWA*5KBZW EUWA*8KBZW EUWA*10KBZW EUWA*12KBZW

Price version N * HUf 959.400,– 1.376.700,– 1.580.000,– 1.905.900,–Price version P * HUf 1.226.700,– 1.644.000,– 1.847.000,– 2.172.900,–Price version B * HUf 1.494.000,– 1.911.000,– 2.114.600,– 2.440.200,–cooling capacity kW 11,3 19,7 22,5 26,5eer 2,53 2,46 2,60 2,30Sound power level dB(A) 67 76 78 78

Options

OPZH glycol application to -5°c lWe HUf 71.500,– 71.500,– 71.500,– 71.500,–OPZL glycol application to -10°c lWe HUf 71.500,– 71.500,– 71.500,– 71.500,–OPHF fan motor size up (50 Pa eSP) HUf 6.900,– 17.000,– 17.000,– 17.000,–

Version * N P B N P B N P B N P BOP10 evaporator heater tape HUf 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,–OPHP pump size up HUf – 29.600,– 29.600,– – 29.600,– 29.600,– – 29.600,– 29.600,– – 29.600,– 29.600,–

Kit

EKSS soft starter kit HUf 124.500,– 124.500,– 124.500,– 124.500,–EKGAU5/8KA gauges kit 5/8Hp units HUf 67.500,– 67.500,– – –EKGAU10/12KA gauges kit 10/12Hp units HUf – – 67.500,– 67.500,–EKAC10C BmS address card HUf 36.900,– 36.900,– 36.900,– 36.900,–EKRUMCA remote user interface HUf 53.400,– 53.400,– 53.400,– 53.400,–EKBT remote buffertank (200 l) HUf 436.200,– 436.200,– 436.200,– 436.200,–

Unit size EUWA*16KBZW EUWA*20KBZW EUWA*24KBZW

Price version N * HUf 2.357.300,– 2.977.900,– 3.376.000,–Price version P * HUf 2.713.100,– 3.333.700,– 3.731.800,–Price version B * HUf 2.980.700,– 3.601.300,– 3.999.100,–cooling capacity kW 34,6 46,6 55,3eer 2,35 2,60 2,32Sound power level dB(A) 79 81 81

Options

OPZH glycol application to -5°c lWe HUf 71.500,– 71.500,– 71.500,–OPZL glycol application to -10°c lWe HUf 71.500,– 71.500,– 71.500,–OPHF fan motor size up (50 Pa eSP) HUf 32.800,– 32.800,– 32.800,–Version * N P B N P B N P BOP10 evaporator heater tape HUf 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,–OPHP pump size up HUf – 111.900,– 111.900,– – 111.900,– 111.900,– – 111.900,– 111.900,–

Kit

EKGAU16KA gauges kit 16Hp units HUf 109.100,– – –EKGAU20/24KA gauges kit 20/24Hp units HUf – 109.100,– 109.100,–EKAC10C BmS address card HUf 36.900,– 36.900,– 36.900,–EKRUMCA remote user interface HUf 53.400,– 53.400,– 53.400,–EKBT remote buffertank (200 l) HUf 436.200,– 436.200,– 436.200,–

note: eKAc10c is needed for direct BmS connection via modbus eKAc10c is needed to install eKrUmcA

Remarks* N = normal unit with mainswitch, flowswitch, without hydraulic module.

P = n-version with hydraulic module with pump & expansion vessel. B = n-version with hydraulic module with buffertank, pump & expansion vessel.

EUWA-KBZW

Page 7: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

7

AIr cooleD HeAt PUmP

→ eUWY-KBZW

Remarks* N = normal unit with mainswitch, flowswitch, without hydraulic module.

P = n-version with hydraulic module with pump & expansion vessel. B = n-version with hydraulic module with buffertank, pump & expansion vessel.

Unit size EUWY*5KBZW EUWY*8KBZW EUWY*10KBZW EUWY*12KBZW

Price version N * HUf 1.103.800,– 1.583.200,– 1.817.100,– 2.191.800,–Price version P * HUf 1.370.400,– 1.850.500,– 2.084.300,– 2.458.800,–Price version B * HUf 1.637.700,– 2.118.100,– 2.351.600,– 2.726.400,–cooling capacity kW 9,1 17,1 21 25eer 2,41 2,32 2,47 2,21Heating capacity kW 11,9 18,5 24 27coP 2,61 2,64 2,67 2,52Sound power level dB(A) 67 76 78 78

Options

OPZH glycol application to -5°c lWe HUf 71.500,– 71.500,– 71.500,– 71.500,–OPZL glycol application to -10°c lWe HUf 71.500,– 71.500,– 71.500,– 71.500,–OPHF fan motor size up (50 Pa eSP) HUf 6.900,– 17.000,– 17.000,– 17.000,–Version * N P B N P B N P B N P BOP10 evaporator heater tape HUf 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,–OPHP pump size up HUf – 29.600,– 29.600,– – 29.600,– 29.600,– – 29.600,– 29.600,– – 29.600,– 29.600,–

Kit

EKSS soft starter kit HUf 124.500,– 124.500,– 124.500,– 124.500,–EKGAU5/8KA gauges kit 5/8Hp units HUf 67.500,– 67.500,– – –EKGAU10/12KA gauges kit 10/12Hp units HUf – – 67.500,– 67.500,–EKAC10C BmS address card HUf 36.900,– 36.900,– 36.900,– 36.900,–EKRUMCA remote user interface HUf 53.400,– 53.400,– 53.400,– 53.400,–EKBT remote buffertank (200 l) HUf 436.200,– 436.200,– 436.200,– 436.200,–

Unit size EUWY*16KBZW EUWY*20KBZW EUWY*24KBZW

Price version N * HUf 2.710.900,– 3.424.500,– 3.882.200,–Price version P * HUf 3.066.800,– 3.781.000,– 4.238.300,–Price version B * HUf 3.333.700,– 4.048.300,– 4.505.300,–cooling capacity kW 34,2 40 50eer 2,30 2,50 2,20Heating capacity kW 37 46 54coP 2,62 2,66 2,52Sound power level dB(A) 79 81 81

Options

OPZH glycol application to -5°c lWe HUf 71.500,– 71.500,– 71.500,–OPZL glycol application to -10°c lWe HUf 71.500,– 71.500,– 71.500,–OPHF fan motor size up (50 Pa eSP) HUf 32.800,– 32.800,– 32.800,–Version * N P B N P B N P BOP10 evaporator heater tape HUf 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,– 47.900,– 96.400,– 118.500,–OPHP pump size up HUf – 111.900,– 111.900,– – 111.900,– 111.900,– – 111.900,– 111.900,–

Kit

EKGAU16KA gauges kit 16Hp units HUf 109.100,– – –EKGAU20/24KA gauges kit 20/24Hp units HUf – 109.100,– 109.100,–EKAC10C BmS address card HUf 36.900,– 36.900,– 36.900,–EKRUMCA remote user interface HUf 53.400,– 53.400,– 53.400,–EKBT remote buffertank (200 l) HUf 436.200,– 436.200,– 436.200,–

note: eKAc10c is needed for direct BmS connection via modbus eKAc10c is needed to install eKrUmcA

EUWY-KBZW

Page 8: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

8

AIr cooleD cHIller

→ eWAQ-DAYn

Unit size EWAQ080DAYN EWAQ100DAYN EWAQ130DAYN EWAQ150DAYN

Price HUf 4.990.500,– 6.219.500,– 7.767.300,– 8.378.100,–cooling capacity kW 80 105 131 152eer 3,03 2,90 2,81 2,70eSeer 4,12 4,00 4,34 4,22Sound power level dB(A) 86 86 88 89

Options

OPSC single pump contactor HUf 83.500,– 83.500,– 83.500,– 83.500,–OPTC twin pump contactor HUf 182.000,– 182.000,– 182.000,– 182.000,–OPSP single pump HUf 678.000,– 678.000,– 678.000,– 678.000,–OPTP twin pump HUf 1.017.300,– 1.017.300,– 1.017.300,– 1.017.300,–OPHP high eSP - single pump HUf 1.017.300,– 1.017.300,– 1.017.300,– 1.017.300,–OPBT buffer tank HUf 493.500,– 493.500,– 493.500,– 493.500,–OPIF inverter fans (for low ambient -15°c) HUf 345.400,– 345.400,– 345.400,– 345.400,–OPZL glycol 0°c / -10°c HUf 70.700,– 70.700,– 70.700,– 70.700,–OP03 dual pressure relief valve HUf 238.600,– 238.600,– 339.000,– 339.000,–OP10 evaporator heater tape HUf 117.400,– 117.400,– 117.400,– 117.400,–OP12 service valves HUf 239.500,– 239.500,– 239.500,– 239.500,–OP57 A-meter / V-meter HUf 166.900,– 166.900,– 166.900,– 166.900,–OPLN low noise (=oPIf + compressor housing) HUf 517.800,– 517.800,– 517.800,– 517.800,–OPCG condenser protection grills HUf 64.600,– 64.600,– 101.700,– 101.700,–

Kit

EKLONPG gateway for lon HUf 325.000,– 325.000,– 325.000,– 325.000,–EKBNPG gateway for BAcnet HUf 325.000,– 325.000,– 325.000,– 325.000,–EKACPG adress card HUf 72.900,– 72.900,– 72.900,– 72.900,–EKRUPG remote user interface HUf 106.200,– 106.200,– 106.200,– 106.200,–EKGN 210 counter pipes HUf 18.300,– 18.300,– 18.300,– 18.300,–

Unit size EWAQ180DAYN EWAQ210DAYN EWAQ240DAYN EWAQ260DAYN

Price HUf 9.909.000,– 10.636.900,– 12.013.000,– 13.183.400,–cooling capacity kW 182 209 236 254eer 2,82 2,80 2,85 2,70eSeer 4,36 4,32 4,20 4,22Sound power level dB(A) 90 90 91 91

Options

OPSC single pump contactor HUf 83.500,– 83.500,– 83.500,– 83.500,–OPTC twin pump contactor HUf 182.000,– 182.000,– 182.000,– 182.000,–OPSP single pump HUf 924.900,– 924.900,– 986.300,– 986.300,–OPTP twin pump HUf 1.387.300,– 1.387.300,– 1.480.000,– 1.480.000,–OPHP high eSP - single pump HUf 1.387.300,– 1.387.300,– 1.480.000,– 1.480.000,–OPBT buffer tank HUf 493.500,– 493.500,– 493.500,– 493.500,–OPIF inverter fans (for low ambient -15°c) HUf 517.800,– 517.800,– 838.800,– 838.800,–OPZL glycol 0°c / -10°c HUf 70.700,– 70.700,– 70.700,– 70.700,–OP03 dual pressure relief valve HUf 339.000,– 339.000,– 339.000,– 339.000,–OP10 evaporator heater tape HUf 117.400,– 117.400,– 117.400,– 117.400,–OP12 service valves HUf 239.500,– 239.500,– 239.500,– 239.500,–OP57 A-meter / V-meter HUf 166.900,– 166.900,– 166.900,– 166.900,–OPLN low noise (=oPIf + compressor housing) HUf 777.100,– 777.100,– 1.258.100,– 1.258.100,–OPCG condenser protection grills HUf 101.700,– 101.700,– 126.300,– 126.300,–

Kit

EKLONPG gateway for lon HUf 325.000,– 325.000,– 325.000,– 325.000,–EKBNPG gateway for BAcnet HUf 325.000,– 325.000,– 325.000,– 325.000,–EKACPG adress card HUf 72.900,– 72.900,– 72.900,– 72.900,–EKRUPG remote user interface HUf 106.200,– 106.200,– 106.200,– 106.200,–EKGN 210 counter pipes HUf 18.300,– 18.300,– – –EKGN 260 counter pipes HUf – – 23.000,– 23.000,–

note: eKAcPG needs to be installed together with eKlonPG and eKBnPG

EWAQ-DAYN

Page 9: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

9

Unit size EWYQ080DAYN EWYQ100DAYN EWYQ130DAYN EWYQ150DAYN

Price HUf 5.852.300,– 6.964.300,– 9.383.900,– 9.916.000,–cooling capacity kW 77 100 136 145eer 2,91 2,76 2,86 2,60eSeer 4,00 3,81 4,31 4,07Heating capacity kW 87,7 114 149 165coP 2,92 2,99 3,00 2,81Sound power level dB(A) 86 86 88 89

Options

OPSC single pump contactor HUf 83.500,– 83.500,– 83.500,– 83.500,–OPTC twin pump contactor HUf 182.000,– 182.000,– 182.000,– 182.000,–OPSP single pump HUf 678.000,– 678.000,– 678.000,– 678.000,–OPTP twin pump HUf 1.017.300,– 1.017.300,– 1.017.300,– 1.017.300,–OPHP high eSP - single pump HUf 1.017.300,– 1.017.300,– 1.017.300,– 1.017.300,–OPBT buffer tank HUf 493.500,– 493.500,– 493.500,– 493.500,–OPIF inverter fans (for low ambient -15°c) HUf 345.400,– 345.400,– 345.400,– 345.400,–OPZL glycol 0°c / -10°c HUf 70.700,– 70.700,– 70.700,– 70.700,–OP03 dual pressure relief valve HUf 238.600,– 238.600,– 339.000,– 339.000,–OP10 evaporator heater tape HUf 117.400,– 117.400,– 117.400,– 117.400,–OP12 service valves HUf 239.500,– 239.500,– 239.500,– 239.500,–OP57 A-meter / V-meter HUf 166.900,– 166.900,– 166.900,– 166.900,–OPLN low noise (=oPIf + compressor housing) HUf 517.800,– 517.800,– 517.800,– 517.800,–OPCG condenser protection grills HUf 64.600,– 64.600,– 101.700,– 101.700,–

Kit

EKLONPG gateway for lon HUf 325.000,– 325.000,– 325.000,– 325.000,–EKBNPG gateway for BAcnet HUf 325.000,– 325.000,– 325.000,– 325.000,–EKACPG adress card HUf 72.900,– 72.900,– 72.900,– 72.900,–EKRUPG remote user interface HUf 106.200,– 106.200,– 106.200,– 106.200,–EKGN 210 counter pipes HUf 18.300,– 18.300,– 18.300,– 18.300,–

Unit size EWYQ180DAYN EWYQ210DAYN EWYQ230DAYN EWYQ250DAYN

Price HUf 11.265.000,– 12.603.600,– 13.560.800,– 14.755.600,–cooling capacity kW 183 211 231 252eer 2,87 2,80 2,81 2,70eSeer 4,33 4,23 4,20 4,00Heating capacity kW 199 225 258 281 coP 2,93 2,92 3,06 2,91Sound power level dB(A) 90 90 91 91

Options

OPSC single pump contactor HUf 83.500,– 83.500,– 83.500,– 83.500,–OPTC twin pump contactor HUf 182.000,– 182.000,– 182.000,– 182.000,–OPSP single pump HUf 924.900,– 924.900,– 986.300,– 986.300,–OPTP twin pump HUf 1.387.300,– 1.387.300,– 1.480.000,– 1.480.000,–OPHP high eSP - single pump HUf 1.387.300,– 1.387.300,– 1.480.000,– 1.480.000,–OPBT buffer tank HUf 493.500,– 493.500,– 493.500,– 493.500,–OPIF inverter fans (for low ambient -15°c) HUf 517.800,– 517.800,– 838.800,– 838.800,–OPZL glycol 0°c / -10°c HUf 70.700,– 70.700,– 70.700,– 70.700,–OP03 dual pressure relief valve HUf 339.000,– 339.000,– 339.000,– 339.000,–OP10 evaporator heater tape HUf 117.400,– 117.400,– 117.400,– 117.400,–OP12 service valves HUf 239.500,– 239.500,– 239.500,– 239.500,–OP57 A-meter / V-meter HUf 166.900,– 166.900,– 166.900,– 166.900,–OPLN low noise (=oPIf + compressor housing) HUf 777.100,– 777.100,– 1.258.100,– 1.258.100,–OPCG condenser protection grills HUf 101.700,– 101.700,– 126.300,– 126.300,–

Kit

EKLONPG gateway for lon HUf 325.000,– 325.000,– 325.000,– 325.000,–EKBNPG gateway for BAcnet HUf 325.000,– 325.000,– 325.000,– 325.000,–EKACPG adress card HUf 72.900,– 72.900,– 72.900,– 72.900,–EKRUPG remote user interface HUf 106.200,– 106.200,– 106.200,– 106.200,–EKGN 210 counter pipes HUf 18.300,– 18.300,– – –EKGN 260 counter pipes HUf – – 23.000,– 23.000,–

note: eKAcPG needs to be installed together with eKlonPG and eKBnPGoPIf needs for heating down to -15°c ambient temperature, without oPIf down to -10°c ambient temperature.

AIr cooleD HeAt PUmP

→ eWYQ-DAYn

EWYQ-DAYN

Page 10: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

10

WAter cooleD cHIller

→ eWWP-KBW1n

Unit size EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N

Price HUf 962.300,– 1.381.200,– 1.584.800,– 1.911.300,–cooling capacity kW 13 21,5 28 32,5eer 3,50 3,61 3,61 3,57Heat rejection capacity kW 16 26,2 35,3 41Sound power level dB(A) 64 64 64 71

Options

OPZH glycol application to -5 °c lWe HUf 71.500,– 71.500,– 71.500,– 71.500,–OPZL glycol application to -10 °c lWe HUf 71.500,– 71.500,– 71.500,– 71.500,–

Kit

EKLS1 low noise kit 5 HP HUf 62.400,– – – – EKLS2 low noise kit 8/10/12 HP HUf – 62.400,– 62.400,– 62.400,–EKAC10C BmS address card HUf 37.000,– 37.000,– 37.000,– 37.000,–EKRUMCA remote user interface HUf 53.400,– 53.400,– 53.400,– 53.400,–EHMC10A10 hydraulic module HUf 682.100,– 682.100,– 682.100,– – EHMC10A80 hydraulic module – pump size up HUf 700.700,– 700.700,– 700.700,– – EHMC15A10 hydraulic module HUf – – 725.600,– 725.600,–EHMC15A80 hydraulic module – pump size up HUf – – 744.500,– 744.500,–

Unit size EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N

Price HUf 2.363.600,– 2.986.100,– 3.385.400,–cooling capacity kW 43 56 65eer 3,55 3,50 3,55Heat rejection capacity kW 52,5 71 82Sound power level dB(A) 67 67 74

Options

OPZH glycol application to -5 °c lWe HUf 71.500,– 71.500,– 71.500,–OPZL glycol application to -10 °c lWe HUf 71.500,– 71.500,– 71.500,–

KitEKLS2 low noise kit 8/10/12 HP (2 pcs.) HUf 124.800,– 124.800,– 124.800,–EKAC10C BmS address card HUf 36.900,– 36.900,– 36.900,–EKRUMCA remote user interface HUf 53.400,– 53.400,– 53.400,–EHMC15A10 hydraulic module HUf 725.600,– – – EHMC15A80 hydraulic module – pump size up HUf 744.500,– – – EHMC30A10 hydraulic module HUf 772.500,– 772.500,– 772.500,–EHMC30A80 hydraulic module – pump size up HUf 797.400,– 797.400,– 797.400,–

note: eKAc10c is needed for direct BmS connection via modbus eKAc10c is needed to install eKrUmcA

EWWP-KBW1N

Page 11: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

11

WAter cooleD cHIller

→ eWWP-KAW1m

Capacity index 090 100 110 120

Basic model eWWP045KAW1meWWP045KAW1m

eWWP045KAW1m eWWP055KAW1m

eWWP055KAW1m eWWP055KAW1m

eWWP055KAW1m eWWP065KAW1m

control box ecB2mUW ecB2mUW ecB2mUW ecB2mUWPrice HUf 4.221.300,– 4.761.900,– 5.302.200,– 5.910.900,–cooling capacity kW 86 99 112 121Sound power level dB(A) 71 71 71 75

Options

oPZH glycol application to -5°c lWe HUf 143.100,– 143.100,– 143.100,– 143.100,–oPZl glycol application to -10°c lWe HUf 143.100,– 143.100,– 143.100,– 143.100,–

Capacity index 130 145 155 165

Basic model eWWP065KAW1m eWWP065KAW1m

eWWP045KAW1m eWWP045KAW1m eWWP055KAW1m

eWWP045KAW1m eWWP055KAW1m eWWP055KAW1m

eWWP055KAW1m eWWP055KAW1m eWWP055KAW1m

control box ecB2mUW ecB3mUW ecB3mUW ecB3mUWPrice HUf 6.519.600,– 6.543.300,– 7.083.900,– 7.624.200,–cooling capacity kW 130 142 155 168Sound power level dB(A) 77 73 73 73

Options

OPZH glycol application to -5°c lWe HUf 143.100,– 214.600,– 214.600,– 214.600,–OPZL glycol application to -10°c lWe HUf 143.100,– 214.600,– 214.600,– 214.600,–

Capacity index 175 185 195

Basic model eWWP055KAW1m eWWP055KAW1m eWWP065KAW1m

eWWP055KAW1m eWWP065KAW1m eWWP065KAW1m

eWWP065KAW1m eWWP065KAW1m eWWP065KAW1m

control box ecB3mUW ecB3mUW ecB3mUWPrice HUf 8.232.900,– 8.841.600,– 9.450.300,–cooling capacity kW 177 186 195Sound power level dB(A) 76 78 79

Options

OPZH glycol application to -5°c lWe HUf 214.600,– 214.600,– 214.600,–OPZL glycol application to -10°c lWe HUf 214.600,– 214.600,– 214.600,–

EWWP-KAW1M

Page 12: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

12

conDenSerleSS cHIller

→ eWlP-KBW1n

Unit size EWLP012KBW1N EWLP020KBW1N EWLP026KBW1N EWLP030KBW1N

Price HUf 866.500,– 1.243.100,– 1.425.900,– 1.720.000,–cooling capacity kW 12,1 20 26,8 31,2eer 2,88 2,98 3,08 3,06Sound power level dB(A) 64 64 64 71

Options

OPZH glycol application to -5°c lWe HUf 71.500,– 71.500,– 71.500,– 71.500,–OPZL glycol application to -10°c lWe HUf 71.500,– 71.500,– 71.500,– 71.500,–

Kit

EKLS1 low noise kit 5 HP HUf 62.400,– – – –EKLS2 low noise kit 8/10/12 HP HUf – 62.400,– 62.400,– 62.400,–EKAC10C BmS address card HUf 36.900,– 36.900,– 36.900,– 36.900,–EKRUMCA remote user interface HUf 53.400,– 53.400,– 53.400,– 53.400,–EHMC10A10 hydraulic module HUf 682.100,– 682.100,– 682.100,– – EHMC10A80 hydraulic module – pump size up HUf 700.700,– 700.700,– 700.700,– – EHMC15A10 hydraulic module HUf – – 725.600,– 725.600,–EHMC15A80 hydraulic module – pump size up HUf – – 744.500,– 744.500,–

Unit size EWLP040KBW1N EWLP055KBW1N EWLP065KBW1N

Price HUf 2.127.200,– 2.687.600,– 3.046.900,–cooling capacity kW 40 53,7 62,4eer 2,96 2,98 3,04Sound power level dB(A) 67 67 74

Options

OPZH glycol application to -5°c lWe HUf 71.500,– 71.500,– 71.500,–OPZL glycol application to -10°c lWe HUf 71.500,– 71.500,– 71.500,–

Kit

EKLS2 low noise kit 8/10/12 HP (2 pcs.) HUf 124.800,– 124.800,– 124.800,–EKAC10C BmS address card HUf 36.900,– 36.900,– 36.900,–EKRUMCA remote user interface HUf 53.400,– 53.400,– 53.400,–EHMC15A10 hydraulic module HUf 725.600,– – –EHMC15A80 hydraulic module – pump size up HUf 744.500,– – –EHMC30A10 hydraulic module HUf 772.500,– 772.500,– 772.500,–EHMC30A80 hydraulic module – pump size up HUf 797.400,– 797.400,– 797.400,–

note: eKAc10c is needed for direct BmS connection via modbus eKAc10c is needed to install eKrUmcA

EWLP-KBW1N

Page 13: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

13

conDenSInG UnIt HeAt PUmP InVerter

→ erQHigh efficiency inverter heat pump outdoor units for connection to DX heat exchanger in Air Handling Units (AHU).

Type for 1~ 230V power supply ERQ100AV1 ERQ125AV1 ERQ140AV1

Price HUf 972.500,– 1.215.500,– 1.361.300,–cooling capacity kW 11,2 14,0 15,5eer 3,99 3,99 3,42Heating capacity kW 12,5 16,0 18,0coP 4,56 4,15 3,94Sound pressure level dB(A) 66 67 69

Type for 3~ 400V power supply ERQ125AW1 ERQ200AW1 ERQ250AW1

Price HUf 1.059.200,– 1.688.800,– 1.969.200,–cooling capacity kW 14,0 22,4 28,0eer 3,98 4,29 3,77Heating capacity kW 16,0 25,0 31,5coP 4,00 4,50 4,09Sound pressure level dB(A) 72 78 78

notes: - Specified capacity values are for evaporation temperature = 6 °c, outdoor temperature 35 °c (cooling) / condensing temperature = 46 °c, outdoor temperature 7 °c (heating), evaporator superheat = 5K, condenser sub-cool = 3K, on-coil temperature = 27 °cDB / 19 °cWB (cooling) / = 20 °cDB (heating), 7,5 m equivalent refrigerant piping, 0 m level difference

Control box EKEQDCB EKEQFCB

control type Daikin control free (external) controlcontrol options room temperature control

[via remote controller (accessory) or via external room temperature sensor (accessory)]

0~10V direct capacity control (5V = maintain capacity,

>5V colder air wanted, <5V warmer air wanted)return air temperature control (via a supplied thermistor) fixed evaporation / condensation temperature control

Price HUf 193.200,– 195.700,–

notes: - A control box is a necessary component of the system- A wired remote controller (Standard or Premium) is required for the eKeQDcB control box; for the eKeQfcB box, it is optional (required for commissioning and servicing only)- Switching between cooling/heating operation with the eKeQfcB box must be done from the external control system, or via the optional Krc19-26 cool/Heat selector

Expansion valve kit Allowed heat exchanger capacity [kW] Combinable unitsMinimum Maximum ERQ100- ERQ125- ERQ140- ERQ200- ERQ250- Price HUf

EKEXV63 6.3 7.8 l l 46.600,–EKEXV80 7.9 9.9 l l l 49.200,–EKEXV100 10.0 12.3 l l l l 51.400,–EKEXV125 12.4 15.4 l l l l l 54.800,–EKEXV140 15.5 17.6 l l l l 56.100,–EKEXV200 17.7 24.6 l l 61.500,–EKEXV250 24.7 30.8 l l 64.900,–

notes: - An expansion valve kit is a necessary component of the system- the expansion valve kit needs to be selected based on the nominal design of the AHU heat exchanger.- the AHU heat exchanger needs to be designed for 40bar pressures, with an internal (refrigerant) volume between 0.3 and 8.3 l (not counting headers and distributors)- Specified capacity values are for evaporation temperature = 6 °c (cooling) / condensing temperature = 46 °c (heating), evaporator superheat = 5K, condenser sub-cool = 3K, on-coil temperature = 27 °cDB / 19 °cWB (cooling) / = 20 °cDB (heating)

Unit specific Accessories ERQ~AV1 ERQ125AW1 ERQ 200~250 AW1 EKEQDCB EKEQFCB Price HUf

BRC1D52 Standard wired remote controller l l 31.200,–BRC1E51A Premium wired remote controller l l 36.300,–KRP4A51 Adaptor for ext. monitoring/control l 48.900,–KRCS01-1 external room temperature sensor l 23.000,–KRC19-26 mechanical cool/heat selector l l 16.700,–KJB111A fixing box for cool/heat selector l l 7.600,–KWC26B160 Drain pan kit

with central drain outletl 240.500,–

KWC26B280 l 335.000,–

notes: - A wired remote controller (Standard or Premium) is required for the eKeQDcB control box; for the eKeQfcB box, it is optional (required for commissioning and servicing only)- Switching between cooling/heating operation with the eKeQfcB box must be done from the external control system, or via the optional Krc19-26 cool/Heat selector

ERQ

Page 14: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

14

→ HYDronIc KIt

Buffer tanks

EKBT 200 l buffer tank with casing HUf 436.200,–EKBT500N 500 l buffer tank HUf 548.100,–EKBTC10N 1000 l buffer tank HUf 759.900,–EKBT500C 500 l buffer tank with casing HUf 1.190.800,–EKBTC10C 1000 l buffer tank with casing HUf 1.587.600,–

Hydraulic modules

EHMC10A10 hydraulic module HUf 682.100,–EHMC10A80 hydraulic module – high eSP HUf 700.700,–EHMC15A10 hydraulic module HUf 725.600,–EHMC15A80 hydraulic module – high eSP HUf 744.500,–EHMC30A10 hydraulic module HUf 772.500,–EHMC30A80 hydraulic module – high eSP HUf 797.400,–

HYDRONIC KIT

Page 15: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

15

Low ESP duct unit FWE-C 02 03 04 06 07 08 10

FWE**CT-, 2 pipe unit, standard, without valves HUf 63.500,– 72.000,– 77.900,– 101.400,– 109.300,– 128.300,– 154.500,–

"FWE**CTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted HUf 108.800,– 117.200,– 123.700,– 147.200,– 155.000,– 173.200,– 199.300,–

FWE**CTT, 2 pipe unit, with 2-ways 230V on/off valve, factory mounted

HUf 89.200,– 97.700,– 103.500,– 127.600,– 134.800,– 153.700,– 179.700,–

Cooling capacity (total at Super High Speed) kW 2,17 3,22 4,34 6,06 6,83 7,84 9,96Heating capacity (2-pipe at Super High Speed) kW 2,79 4,28 5,61 7,66 9,26 10,50 13,00FWE**CF-, 4 pipe unit, standard, without valves HUf 74.000,– 83.800,– 91.000,– 117.200,– 125.000,– 146.600,– 172.800,–

FWE**CFV, 4 pipe unit, with 3-ways 230V on/off valves, factory mounted HUf 154.300,– 164.100,– 171.300,– 197.300,– 205.100,– 226.600,– 252.700,–

FWE**CFT, 4 pipe unit, with 2-ways 230V on/off valves, factory mounted HUf 125.000,– 134.800,– 142.000,– 168.000,– 175.800,– 197.300,– 223.400,–

Cooling capacity (total at Super High Speed) kW 2,10 3,16 3,98 6,05 6,76 7,79 9,91Heating capacity (4-pipe at Super High Speed) (1) kW 2,30 3,53 4,56 6,17 7,60 8,52 10,40

Accessories for FWE-C 02 03 04 06 07 08 10

2 pipes 3-ways on/off 230V valve kit EK2MV3B10C5 HUf 21.700,–

2 pipes 2-ways on/off 230V valve kit EK2MV2B10C5HUf 18.100,–

4 pipes 3-ways on/off 230V valve kit EK4MV3B10C5 HUf 41.300,–

4 pipes 2-ways on/off 230V valve kit EK4MV2B10C5HUf 35.600,–

Controller for FWE-C 02 03 04 06 07 08 10

Controller electronicStandard version, (see note 2)

FWEC1AHUf 24.600,–

Controller electronicAdvanced version

FWEC2AHUf 38.800,–

Controller electronicAdvanced Plus version

FWEC3AHUf 53.000,–

Wall mounting kit (spacing collar)for fWec*A

FWFCKAHUf 4.700,–

Temperature sensor kitfor fWec*A

FWTSKAHUf 2.500,–

Relative humidity sensor kitfor fWec2A and fWec3A

FWHSKAHUf 6.000,–

Master / Slave interface EPIMSB6HUf 36.000,–

notes:

(1) rating conditions: air 20°c DB, entering water 50°c, leaving water 40°c

(2) fWec1A can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit

fAn coIl, AcceSSorIeS

→ fWe-c 4-speed fan motor, available static pressure up to 50Pa

FWE-C, Low ESP duct fan coil

Page 16: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

16

Medium ESP duct unit FWB-B 02 03 04 05 06 07 08 09 10

FWB**BTN, 2 pipe unit, standard, without valves HUf 133.800,– 143.000,– 151.600,– 183.000,– 189.400,– 207.600,– 250.300,– 264.800,– 281.700,–

FWB**BTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted HUf 177.400,– 186.000,– 194.600,– 226.000,– 232.500,– 250.300,– 296.100,– 309.700,– 327.500,–

FWB**BTNE, 2 pipe unit, without valves and electric heater, factory mounted HUf 215.900,– 225.400,– 234.000,– 274.600,– 281.100,– 298.300,– 347.500,– 361.900,– 379.100,–

FWB**BTVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted HUf 258.900,– 268.100,– 276.800,– 317.600,– 324.100,– 341.000,– 393.300,– 406.800,– 425.000,–

Cooling capacity (total at High Speed) kW 2,61 3,14 3,49 5,08 5,45 6,47 7,57 8,67 10,34Heating capacity (2-pipe at High Speed) kW 5,47 6,01 6,47 10,31 11,39 12,28 15,05 16,85 18,78Heating capacity (4-pipe at High Speed) kW 3,14 3,14 3,14 5,99 5,99 5,99 12,80 12,80 12,80

Factory mounted option 02 03 04 05 06 07 08 09 10

DC fan motor (version FWP**A) HUf on request - -

Accessories for FWB-B 02 03 04 05 06 07 08 09 10

Additional single row heat exchanger

EAH04A6 EAH07A6 EAH10A6HUf 52.000,– 58.600,– 76.900,–

3-way valve add. h/e E2MV307A6 E2MV310A6HUf 55.500,– 55.500,–

2-way valve add. h/e E2MV207A6 E2MV210A6HUf 28.400,– 30.300,–

Fan stop thermostat YFSTA6HUf 5.000,–

Controller for FWB-B 02 03 04 05 06 07 08 09 10

Controller electronic Standard version

FWEC1AHUf 24.600,–

Controller electronic Advanced version

FWEC2AHUf 38.800,–

Controller electronic Advanced Plus version

FWEC3AHUf 53.000,–

Wall mounting kit (spacing collar)for fWec*A

FWFCKAHUf 4.700,–

Temperature sensor kitfor fWec*A

FWTSKAHUf 2.500,–

Relative humidity sensor kitfor fWec2A and fWec3A

FWHSKAHUf 6.000,–

Master / Slave interface EPIMSB6HUf 36.000,–

fAn coIl, AcceSSorIeS

→ fWB-B Low sound power levels and electrical absorption thanks to plastic impeller and improved electric motor.

FWB-B, Medium ESP duct fan coil

Page 17: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

17

2-pipe unit FWD**AT 04 06 08 10 12 16 18

Price HUf 160.800,– 212.500,– 248.200,– 276.100,– 343.200,– 440.600,– 484.300,–Cooling capacity (total at High Speed) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30Heating capacity (2-pipe at High Speed) kW 4,05 7,71 9,43 10,79 14,45 19,81 21,92

4-pipe unit FWD**AF 04 06 08 10 12 16 18

Price HUf 188.800,– 246.600,– 288.100,– 319.800,– 402.500,– 509.800,– 559.300,–Cooling capacity (total at High Speed) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30Heating capacity (4-pipe at High Speed) kW 4,49 6,62 9,21 9,21 15,86 21,15 21,15

Accessories for FWD 04 06 08 10 12 16 18

Electric heater low capacity

EDEH04A6 EDEHS06A6 EDEHS10A6 EDEHS12A6 EDEHS18A6HUf 76.600,– 144.200,– 144.200,– 147.300,– 166.100,–

Electric heater high capacity

EDEH04A6 EDEHB06A6 EDEHB10A6 EDEHB12A6 EDEHB18A6HUf 76.600,– 144.200,– 144.200,– 147.300,– 166.100,–

2-pipe 3-way valve ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6HUf 54.700,– 57.200,– 52.900,– 60.600,–

4-pipe 3-way valve ED4MV04A6 ED4MV10A6 2 x ED2MV12A6 2 x ED2MV18A6HUf 104.600,– 111.600,– 100.100,– 104.700,–

Vertical drainpan EDDPV10A6 EDDPV18A6HUf 3.700,– 4.900,–

Horizontal drainpan EDDPH10A6 EDDPH18A6HUf 5.200,– 6.500,–

Fan stop thermostat YFSTA6HUf 5.000,–

Fresh air intake EDMFA04A6 EDMFA06A6 EDMFA10A6 EDMFA12A6 EDMFA18A6HUf 262.300,– 267.800,– 273.100,– 288.400,– 293.400,–

Controller for FWD 04 06 08 10 12 16 18

Controller electronic Standard version

FWEC1A FWEC1AePIB6 requested

HUf 24.600,– 24.600,–Controller electronic Advanced version

FWEC2A FWEC2AePIB6 requested

HUf 38.800,– 38.800,–Controller electronic Advanced Plus version

FWEC3A FWEC3A ePIB6 requested

HUf 53.000,– 53.000,–Wall mounting kit (spacing collar) for fWec*A

FWFCKAHUf 4.700,–

Temperature sensor kit for fWec*A

FWTSKAHUf 2.500,–

Relative humidity sensor kit for fWec2A and fWec3A

FWHSKAHUf 6.000,–

Master / Slave interface EPIMSB6HUf 36.000,–

Power interface – EPIB6HUf – 37.800,–

note: for fWD size 12, 16 or 18 ePIB6 needs to be used for each fWD unit to connect to fWec*A controllers.If fWD size 12, 16 or 18 are used in master/Slave application by using ePImSB6 still ePIB6 needs to be used for each fWD to connect to ePImSB6.

fAn coIl, AcceSSorIeS

→ fWD Straight duct connector is mounted to discharge side

FWD, High ESP flexi type fan coil

Page 18: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

18

FWF-C cassette unit 02 03 04

FWF**CT, 2 pipe unit, incl. condensate pump, without valves HUf 146.700,– 165.100,– 167.300,–

Cooling capacity (total at High Speed) kW 2,49 4,10 4,54Heating capacity (2-pipe at High Speed) kW 3,52 4,69 5,28

note: Decoration panel is mandatory, it is included with other accessories in table on page 19.

FWF-B cassette unit 02 03 04 05

FWF**BT, 2 pipe unit, incl. condensate pump, without valves HUf 191.900,– 209.600,– 225.400,– 237.300,–

Cooling capacity (total at Super High Speed) kW 2,00 3,20 4,20 5,20Heating capacity (2-pipe at Super High Speed) kW 2,90 4,00 5,40 6,70FWF**BF, 4 pipe unit, incl. condensate pump, without valves HUf 213.400,– 231.700,– 243.000,– 255.000,–

Cooling capacity (total at Super High Speed) kW 2,00 2,70 3,50 4,50Heating capacity (4-pipe at Super High Speed) kW 3,80 3,80 4,90 6,10

note: Decoration panel is mandatory, it is included with other accessories in table on page 21.

FWC-B cassette unit 06 07 08 09

FWC**BT, 2 pipe unit, incl. condensate pump, without valves HUf 276.400,– 285.100,– 298.600,– 309.300,–

Cooling capacity (total at High Speed) kW 5,80 6,80 7,70 8,70Heating capacity (2-pipe at High Speed) kW 8,00 8,90 10,60 12,10FWC**BF, 4 pipe unit, incl. condensate pump, without valves HUf 295.500,– 304.700,– 314.000,– 324.700,–

Cooling capacity (total at High Speed) kW 5,80 6,60 7,60 8,70Heating capacity (4-pipe at High Speed) kW 7,50 8,40 9,70 11,00

note: Decoration panel is mandatory, it is included with other accessories in table on page 20.

fAn coIl

→ fWf-c Infrared remote control as standard with decoration panel kit.

fAn coIl

→ fWf-B Possibility to shut 1 or 2 flaps for easy installations in corners.

fAn coIl

→ fWc-B 360° air discharge ensures uniform air flow and temperature distribution.

FWF-C, FWF-B, FWC-B, Cassette fan coils

Page 19: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

19

Type FWF-CT FWT-CT

Decoration panel 2-pipe Incl. wireless controller

DCP600TB–

HUf 46.700,–Standard wired remote control MERCA

HUf 36.000,–Simplified wired remote control SRC-COA

HUf 17.800,–Simplified wired remote control SRC-HPA

HUf 17.800,–Wireless control WRC-HPC

HUf 7.400,–2-pipe 3-way valve MCKCW2T3VN

–HUf 34.400,–

FWT-C wall mounted unit 02 03 04 05 06

FWT**CT, 2 pipe unit, without valves HUf 92.300,– 103.000,– 104.600,– 142.400,– 145.100,–

Cooling capacity (total at High Speed) kW 2,34 2,78 3,22 4,54 5,28Heating capacity (2-pipe at High Speed) kW 3,02 3,75 4,10 6,01 6,74

fAn coIl

→ fWt-c Flexibility via interchangeable water connection side.

AcceSSorIeS

→ fWt-c + fWf-c

FWT-C, Wall mounted fan coil

Accessories for FWT-C, FWF-C

Page 20: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

20

Options

BYCQ140C Decoration Panel round flow Standard HUf 71.900,–KDBHQ55C140 Sealing member of air discharge outlet HUf 28.700,–KAFP551K160 long-life filter HUf 27.100,–CE.KDDQ55C140 fresh air intake kit (20% fresh air) HUf 156.000,–

Control Systems

BRC7F532F (11) remote control Infrared H/P HUf 50.400,–BRC7F533F (11) remote control Infrared c/o HUf 35.900,–BRC315D (1) remote control Wired HUf 31.800,–DCS302C51 (2) central remote control HUf 489.800,–KJB311A electrical box with earth terminal (3 blocks) HUf 21.700,–DCS301B51 (5) Unified on/off control HUf 205.800,–KJB212A electrical box with earth terminal (2 blocks) HUf 21.100,–DST301B51 (5)(8) Shedule timer HUf 257.800,–KRP2A52 (4)(8) Wiring adapter for electrical appendices 1 HUf 107.200,–KRP4A53 (4)(8) Wiring adapter for electrical appendices 2 HUf 48.900,–KRP1H98 (9) Installation box for adapter PcB HUf 15.100,–KRCS01-4 remote Sensor HUf 23.000,–DCS601C51 (3)(7) Intelligent touch controller HUf 543.900,–KJB411A electrical installation box HUf 37.500,–EKFCMBCB (4)(8) optional PcB for moD-bus connection HUf 24.600,–EKMV2C09B (4)(6)(10) 2-way valve - on/off HUf 20.500,–EKMV3C09B (4)(6)(10) 3-way valve - on/off HUf 23.300,–EKRP1C11 Valve control PcB HUf 22.800,–

notes:1. optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall.2. requires electrical installation box with earth terminal KJB311A.3. requires electrical installation box KJB411A.4. requires installation box KrP1H98.5. requires electrical installation box with earth terminal KJB212A, if built in the wall.6. requires valve control PcB eKrP1c11.7. I-touch:

• Not allowed to use the i-touch for an installation with both fan coils and VRV units. • Can not be used in combination with fan coil units, that use MOD bus communication. • No Airnet or telephone connection possible.

8. only 1 of these 4 options can be installed on 1 indoor unit.9. max. 1 KrP1H98 box can be mounted on the unit. max. 2 PcB’s can be mounted in 1 KrP1H98 box.10. 2-pipe unit: 1 x valve kit + 1 x installation box for PcB KrP1H98 + 1 x valve control PcB eKrP1c11

4-pipe unit: 2 x valve kit + 1 x installation box for PcB KrP1H98 + 1 x valve control PcB eKrP1c1111. It is possible to change the operation mode, but this will not have an impact on the water temperature.

(no feed back to water source) It is not possible to select the “auto air flow” setting. Dry operation can be selected with this remote control, but this function is not available on the fWc model.

All options are supplied as kit.

AcceSSorIeS

→ fWc-B

Accessories for FWC-B

Page 21: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

21

Options

BYFQ60B Decoration Panel 4-way blow HUf 46.600,–KDBH44BA60 Sealing member of air discharge outlet HUf 40.300,–KDBQ44B60 Panel spacer HUf 147.500,–KAFQ441BA60 long-life filter HUf on requestKDDQ44XA60 fresh air intake kit HUf 46.300,–

Control Systems

BRC7E530 (12) remote control Infrared H/P HUf 50.700,–BRC7E531 (12) remote control Infrared c/o HUf 83.500,–BRC315D (1) remote control Wired HUf 31.800,–DCS302C51 (2) central remote control HUf 489.800,–KJB311A electrical box with earth terminal (3 blocks) HUf 21.700,–DCS301B51 (5) Unified on/off control HUf 205.800,–KJB212A electrical box with earth terminal (2 blocks) HUf 21.100,–DST301B51 (5)(8) Shedule timer HUf 257.800,–KRP2A52 (5)(8) Wiring adapter for electrical appendices 1 HUf 107.200,–KRP4A53 (5)(8) Wiring adapter for electrical appendices 2 HUf 48.900,–KRP1BA101 (9) Installation box for adapter PcB HUf 19.700,–KRCS01-1 remote Sensor HUf 23.000,–DCS601C51 (3)(7) Intelligent touch controller HUf 543.900,–KJB411A electrical installation box HUf 37.500,–EKFCMBCB (4)(8) optional PcB for moD-bus connection HUf 24.600,–EKMV2C09B (4)(6)(10) 2-way valve - on/off HUf 20.500,–EKMV3C09B (4)(6)(10) 3-way valve - on/off HUf 23.300,–EKRP1C11 Valve control PcB HUf 22.800,–EKRORO (11) remote “on/off” and “forced off” kit HUf 7.900,–

notes:1. optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall.2. requires electrical installation box with earth terminal KJB311A.3. requires electrical installation box KJB411A.4. requires installation box KrP1BA101.5. requires electrical installation box with earth terminal KJB212A, if built in the wall.6. requires valve control PcB eKrP1c11.7. I-touch:

• Not allowed to use the i-touch for an installation with both fan coils and VRV units. • Can not be used in combination with fan coil units, that use MOD bus communication. • No Airnet or telephone connection possible.

8. only 1 of these 4 options can be installed on 1 indoor unit.9. max. 2 KrP1BA101 boxes can be mounted on the unit. max. 1 PcB can be mounted in 1 KrP1BA101 box.10. 2-pipe unit: 1 x valve kit + 1 x installation box for PcB KrP1BA101 + 1 x valve control PcB eKrP1c11.

4-pipe unit: 2 x valve kit + 1 x installation box for PcB KrP1BA101 + 1 x valve control PcB eKrP1c11.11. this option is needed to create t1 t2 wire.12. It is possible to change the operation mode, but this will not have an impact on the water temperature.

(no feed back to water source) It is not possible to select the “auto air flow” setting. Dry operation can be selected with this remote control, but this function is not available on the fWf model.

All options are supplied as kit.

AcceSSorIeS

→ fWf-B

Accessories for FWF-B

Page 22: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

22

FWV, Floor standing fan coil

fAn coIl

→ fWV

Low Wall unit FWV 01 15 02 25 03 35 04 06 08 10

FWV**DTN, 2 pipe unit, standard, without valve

HUf 89.500,– 84.700,– 98.700,– 95.700,– 108.900,– 108.100,– 125.200,– 135.300,– 179.600,– 203.900,–

FWV**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

HUf 152.200,– 142.000,– 161.700,– 153.400,– 171.600,– 166.400,– 189.400,– 199.600,– 248.800,– 273.100,–

FWV**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

HUf 110.700,– 114.000,– 118.500,– 125.000,– 127.600,– 136.800,– 144.600,– 153.700,– 194.700,– 216.200,–

Cooling capacity (total) kW 1.54 1.74 1.96 2.42 2.93 3.51 4.33 4.77 6.71 8.02Heating capacity (2-pipe at High Speed) kW 2.14 2.20 2.57 3.20 3.81 4.78 5.10 5.95 7.83 10.03FWV**DFN, 4 pipe unit, standard, without valves

HUf 103.600,– 99.000,– 113.800,– 110.700,– 125.800,– 123.100,– 145.800,– 157.400,– 206.000,– 229.700,–

FWV**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

HUf 216.800,– 201.200,– 226.600,– 213.000,– 238.900,– 226.000,– 258.900,– 270.300,– 324.700,– 349.000,–

FWV**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

HUf 152.400,– 157.000,– 161.500,– 168.700,– 172.600,– 181.700,– 193.400,– 203.800,– 250.100,– 272.200,–

Cooling capacity (total) kW 1.46 1.69 1.79 2.38 2.87 3.46 4.26 4.67 6.64 7.88Heating capacity (4-pipe at High Speed) kW 1.90 2.02 2.01 2.92 3.08 4.80 5.05 5.30 7.91 8.35

Factory mounted options 01 15 02 25 03 35 04 06 08 10

3-way on/off 24V valve HUf on request3-way proportional on/off valves HUf on request2-way on/off 230V valve HUf on request2-way on/off 24V valves HUf on request2-way proportional on/off valve HUf on request4-rows coil (for 2 pipe unit only) HUf on requestDC fan motor (version fWZ**A) HUf on request6-speeds fan motor HUf - on request - on r.Electric heater (for 2 pipe unit only) HUf on request

Factory mounted options 01 15 02 25 03 35 04 06 08 10FWEC1A Standard version HUf on requestFWEC2A Advanced version HUf on requestFWEC3A Advanced Plus version HUf on request

notes:Accessories as kits are included on page 25.Additional single row h/e (4-row coil) can not be used in combination with electric heater.Independent power supply is necessary for 24 V valve. fWec1/2/3A are not suitable to control 24 V valve.controller fWec3A is necessary for proportional valve.cooling capacity is related to High Speed, standard unit.

Page 23: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

23

FWL, Flexi type fan coil

fAn coIl

→ fWl

Flexible unit FWL 01 15 02 25 03 35 04 06 08 10

FWL**DTN, 2 pipe unit,standard, without valve

HUf 93.800,– 89.900,– 105.200,– 99.600,– 116.500,– 114.000,– 132.200,– 142.400,– 191.600,– 216.800,–

FWL**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

HUf 155.300,– 145.200,– 166.100,– 155.000,– 178.000,– 170.600,– 195.900,– 206.000,– 260.500,– 285.400,–

FWL**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

HUf 114.000,– 118.500,– 123.700,– 128.300,– 134.800,– 142.600,– 150.400,– 159.600,– 205.100,– 227.900,–

Cooling capacity (total) kW 1.54 1.74 1.96 2.42 2.93 3.51 4.33 4.77 6.71 8.02Heating capacity (2-pipe at High Speed) kW 2.14 2.20 2.57 3.20 3.81 4.78 5.10 5.95 7.83 10.03FWL**DFN, 4 pipe unit,standard, without valves

HUf 110.100,– 104.200,– 118.700,– 115.900,– 132.200,– 132.900,– 154.400,– 164.500,– 218.900,– 242.300,–

FWL**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

HUf 221.100,– 204.500,– 229.700,– 216.200,– 243.200,– 233.100,– 265.400,– 275.200,– 335.500,– 359.200,–

FWL**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

HUf 157.000,– 161.500,– 164.800,– 173.200,– 177.800,– 190.200,– 199.900,– 209.100,– 261.200,– 282.600,–

Cooling capacity (total) kW 1.46 1.69 1.79 2.38 2.87 3.46 4.26 4.67 6.64 7.88Heating (4-pipe at High Speed) kW 1.90 2.02 2.01 2.92 3.08 4.80 5.05 5.30 7.91 8.35

Factory mounted options 01 15 02 25 03 35 04 06 08 10

3-way on/off 24V valve HUf on request3-way proportional on/off valves HUf on request2-way on/off 230V valve HUf on request2-way on/off 24V valves HUf on request2-way proportional on/off valve HUf on request4-rows coil (for 2 pipe unit only) HUf on requestDC fan motor (version fWr**A) HUf on request6-speeds fan motor HUf - on request - on r.Electric heater (for 2 pipe unit only) HUf on request

Factory mounted options 01 15 02 25 03 35 04 06 08 10FWEC1A Standard version HUf on requestFWEC2A Advanced version HUf on requestFWEC3A Advanced Plus version HUf on request

notes: Accessories as kits are included on page 25. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. fWec1/2/3A are not suitable to control 24 V valve. controller fWec3A is necessary for proportional valve. cooling capacity is related to High Speed, standard unit.

Page 24: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

24

fAn coIl

→ fWm

Flexible concealed unit FWM 01 15 02 25 03 35 04 06 08 10

FWM**DTN, 2 pipe unit, standard, without valve

HUf 75.900,– 81.500,– 83.700,– 89.300,– 92.500,– 99.400,– 104.400,– 113.800,– 150.200,– 170.500,–

FWM**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

HUf 138.600,– 142.000,– 146.700,– 150.500,– 155.200,– 161.500,– 168.300,– 178.700,– 220.100,– 239.800,–

FWM**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

HUf 108.500,– 114.200,– 116.400,– 122.000,– 125.100,– 132.000,– 139.800,– 149.200,– 186.900,– 208.000,–

Cooling capacity (total) kW 1.54 1.74 1.96 2.42 2.93 3.51 4.33 4.77 6.71 8.02Heating capacity (2-pipe at High Speed) kW 2.14 2.20 2.57 3.20 3.81 4.78 5.10 5.95 7.83 10.03"FWM**DFN, 4 pipe unit, standard, without valves

HUf 91.200,– 94.100,– 97.800,– 106.000,– 110.000,– 118.500,– 126.000,– 134.800,– 176.500,– 197.500,–

FWM**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

HUf 204.100,– 206.900,– 210.700,– 217.900,– 223.200,– 231.400,– 239.200,– 248.000,– 295.300,– 316.300,–

FWM**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

HUf 155.200,– 158.000,– 161.800,– 169.900,– 174.000,– 182.500,– 194.100,– 202.200,– 247.300,– 269.000,–

Cooling capacity (total) kW 1.46 1.69 1.79 2.38 2.87 3.46 4.26 4.67 6.64 7.88Heating capacity (4-pipe at High Speed) kW 1.90 2.02 2.01 2.92 3.08 4.80 5.05 5.30 7.91 8.35

Factory mounted options 01 15 02 25 03 35 04 06 08 10

3-way on/off 24V valve HUf on request3-way proportional on/off valves HUf on request2-way on/off 230V valve HUf on request2-way on/off 24V valves HUf on request2-way proportional on/off valve HUf on request4-rows coil (for 2 pipe unit only) HUf on requestDC fan motor (version fWS**A) HUf on request6-speeds fan motor HUf - on request - on r.Electric heater (for 2 pipe unit only) HUf on request

notes:Accessories as kits are included on page 25.Additional single row h/e (4-row coil) can not be used in combination with electric heater.Independent power supply is necessary for 24 V valve. fWec1/2/3A are not suitable to control 24 V valve.controller fWec3A is necessary for proportional valve.cooling capacity is related to High Speed, standard unit.

FWM, Flexi concealed fan coil

Page 25: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

25

Accessories as a kit for FWV/FWL/FWM 1 15 2 25 3 35 4 6 8 10

Additional heat exchanger ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6HUf 16.100,– 18.600,– 21.100,– 28.700,–

electric heater EEH01A6 EEH02A6 EEH03A6 EEH06A6 EEH10A6HUf 73.100,– 73.100,– 78.200,– 82.300,– 84.800,–

2-pipe 3-ways 230V on/off valve kit E2MV03A6 E2MV06A6 E2MV10A6HUf 51.400,– 54.800,– 58.900,–

4-pipe 3-ways 230V on/off valve kit E4MV03A6 E4MV06A6 E4MV10A6HUf 95.300,– 99.300,– 103.900,–

2-ways 230V on/off valve kit cooling h/e E2MV207A6 E2MV210A6HUf 28.400,– 30.300,–

2-ways 230V on/off valve kit additional h/e E2MV207A6HUf 28.400,–

2-pipe simplified 3-ways 230V on/off valve kit E2MVD03A6 E2MVD06A6 E2MVD10A6HUf 28.600,– 29.200,– 29.200,–

4-pipe simplified 3-ways 230V on/off valve kit E4MVD03A6 E4MVD06A6 E4MVD10A6HUf 52.500,– 53.700,– 54.200,–

2-pipe 3-ways 24V on/off valve kit E2M2V03A6 E2M2V06A6 E2M2V10A6HUf 49.000,– 49.000,– 51.900,–

4-pipe 3-ways 24V on/off valve kit E4M2V03A6 E4M2V06A6 E4M2V10A6HUf 87.500,– 87.500,– 92.100,–

2-pipe 3-ways proportional valve kit E2MPV03A6 E2MPV06A6 E2MPV10A6HUf 77.000,– 75.800,– 78.200,–

4-pipe 3-ways proportional valve kit E4MPV03A6 E4MPV06A6 E4MPV10A6HUf 141.700,– 142.300,– 144.100,–

2-ways 24V on/off valve kit cooling h/e E2M2V207A6 E2M2V210A6HUf 21.000,– 21.000,–

2-ways 24V on/off valve kit additional h/e E2M2V207A6HUf 21.000,–

2-ways proportional valve kit cooling h/e E2MPV207A6 E2MPV210A6HUf 53.700,– 53.700,–

2-ways proportional valve kit additional h/e E2MPV207A6HUf 53.700,–

fan stop thermostat YFSTA6HUf 5.000,–

Air intake & discharge grille EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6HUf 47.600,– 57.700,– 72.500,– 85.400,–

Supporting feet ESFV06A6 ESFV10A6HUf 5.400,– 6.300,–

Supporting feet & grille ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6HUf 8.500,– 10.100,– 12.000,– 16.400,–

fresh air intake EFA02A6 EFA03A6 EFA06A6 EFA10A6HUf 20.200,– 21.100,– 23.600,– 26.500,–

rear panel ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6HUf 9.100,– 11.700,– 13.200,– 17.300,–

Plenum box with circular connections (only for fWm-D)

EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6 HUf 21.600,– 23.900,– 29.700,– 41.400,–

Vertical auxiliary drainpan EDPVB6HUf 1.500,–

Horizontal auxiliary drainpan EDPHB6HUf 1.500,–

Controller as a kit for FWV/FWL/FWM all sizes

ECFWMB6 controller electromechanical, Built in HUf 11.000,–FWEC1A Wired remote controller, Standard version HUf 24.600,–FWEC2A Wired remote controller,

Advanced versionHUf 38.800,–

FWEC3A Wired remote controller, Advanced Plus version

HUf 53.000,–

FWECKA on board mounting kit, for fWec*A, remote airprobe incl.

HUf 4.400,–

FWFCKA Wall mounting kit (spacing collar), for fWec*A HUf 4.700,–FWTSKA temperature sensor kit , for fWec*A HUf 2.500,–FWHSKA relative humidity sensor kit ,

for fWec2A and fWec3AHUf 6.000,–

EPIMSB6 master / Slave interface HUf 36.000,–

Accessories for FWV - FWL - FWM

AcceSSorIeS

→ fWV – fWl – fWm

Page 26: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

26

PLUG and PLAY VRV® connection AHU

With the new DAIKIN “PLUG and PLAY” VRV connection system

VRV indoor units and Air Handling Units for fresh air treat-

ment can be connected to the same refrigerant line, re-

sulting in enhanced design flexibility and increased energy

efficiency. Both fresh air treatment and air conditioning

can be achieved successfully in a single direct-expansion

system via DAIKIN VRV technology without the usual de-

sign problems of needing VRV system for air conditioning and

separate individual heating and cooling systems just for the

Air Handling Units.

The factory engineered and mounted controls package of the

Air Handling Units assures a fast and easy “PLUG and PLAY”

connection of the Air Handling Units just like a standard

VRV indoor unit.

This innovation brings a total monovalent direct-

expansion solution to the heating, cooling and fresh air

treatment demands of air conditioning applications.

In addition the Daikin Inverter technology for step-less and

efficient capacity control combined with the highly so-

phisticated factory engineered and mounted Air Handling

Unit controls are ensuring constant and comfortable sup-

ply air temperature.

Last but not least not to forget about the business advan-

tages in which the DAIKIN “PLUG and PLAY” VRV connection

will put you. The possibility of connecting the Air Handling

Units together with the standard VRV indoor units in a mon-

ovalent heating and cooling VRV system gives you the oppor-

tunity to completely get rid off the fossil fuel burning boilers,

the chillers and the water piping from your projects and so

reduce the total investment cost significantly.

Altogether, the Daikin “PLUG and PLAY” VRV connection sys-

tem offers you the most efficient, easiest to install technol-

ogy with lowest investment costs for the cooling and heating

needs of your air conditioning projects.

Air Handling Units for

› VRV Indoor units and Air Handling Units on single VRV system

› Monovalent cooling and heating for Air Handling Units

› Air Handling Unit connection like standard VRV indoor unit

› Factory engineered and mounted controls › Constant and comfortable supply air

temperature control › Fast and easy installation › Standard DAIKIN warranty

Page 27: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

27

Factory engineered and mounted controlsFor all Air Handling Units of the “PLUG and PLAY” VRV connection system a

factory engineered and factory mounted controls package is included.

This package consists of:

› Expansion valve kits EKEXV which are already mounted inside the unit

so that only the refrigerant piping has to be connected.

› Factory mounted control equipment for the AHU like temperature-, pressure sensors, dampers …

› Control panel to control the whole AHU based on supply temperature including EKEQMCB boxes.

This assures a fast and easy “PLUG and PLAY” connection

of the Air Handling Units to a VRV system just like a

standard VRV indoor unit. The possibility of operating the

Air Handling Unit by using standard DAIKIN remote control

greatly simplifies overall system control. Using a centralized

remote control enables the user to choose from a wide range

of control systems that integrate air conditioning and ven-

tilation in a single control system structure.

PLUG and PLAY VRV® connection AHU

Standardized preconfigured Air Handling UnitsThe following preconfigured Air Handling Units are especially designed to meet the requirements which go along with the

“PLUG and PLAY” VRV connection system as well as to assure maximum energy efficiency and comfort level for standard air

conditioning applications.

Preconfigured Air Handling Unit Factory mounted controls+

Page 28: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

28

→ Standard spec. supply air only units for cooling only applications

These units are single air stream (Supply fan only) with integrated mixing box (0-100% fresh air) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling mode only. Structure: Natural aluminum frame 40 mm, Flat panel 25 mm with foam insulation (40 ÷ 50 kg/m3), Skin material external Grey plastisol 0,7 mm, Skin material internal galvanized 0,5 mm

Components in Order of the direction of air flow: 1) Mixing box with dampers including 1 x louver, 1 x flexible connection and factor fitted actuators, 2) F5 bag filter with factory mounted differential pressure gauge and hinged door, 3) Section for factory mounted expansion valve kits EKEXV4) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 5) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 6) Flexible connection, 7) 150 mm base frame

Air flow m3/h 2.000 3.000 4.000 6.000 8.000 10.000 12.000

Width mm 950 1000 1150 1350 1550 1550 1650Height mm 800 930 950 1050 1050 1250 1300length mm 3030 3250 3590 3360 3680 3950 4050Weight kg ~ 300 ~ 350 ~ 400 ~ 470 ~600 ~700 ~700cooling capacity total kW 20,60 28,80 40,70 58,70 83,40 100,30 117,30cooling capacity sensible kW 10,90 16,40 22,00 32,90 43,40 55,20 65,70external static pressure Pa 450 450 450 450 450 450 450max. Power input fan kW 1,10 1,50 2,20 3,00 5,50 5,50 7,50Price HUf 4.542.000,– 4.780.600,– 5.743.900,– 6.076.200,– 7.336.800,– 8.389.400,– 9.199.400,–

Included VrV connection kit 1 x eKeXV2001 x eKeQmcB

1 x eKeXV2501 x eKeQmcB

2 x eKeXV2002 x eKeQmcB

2 x eKeXV2502 x eKeQmcB

3 x eKeXV2503 x eKeQmcB

4 x eKeXV2004 x eKeQmcB

4 x eKeXV2504 x eKeQmcB

capacity index 1 x 184 1 x 257 2 x 182 2 x 262 3 x 248 4 x 224 4 x 262

conditions: outside air: Summer 35 °c/50% r.H.; Supply air: Summer 19 °c1) Height including 150 mm Base frame2) Width and Height without factory mounted control panel3) eKeXVs mounted inside Air Handling unit. eKeQmcB mounted inside control panel4) maximum connection ratio (cr) of the total VrV system: 110%5) Sum of capacity Indexes of eKeXVs must not exceed 30% when used in a system with other indoor units

PLUG and PLAY VRV® connection AHU

Page 29: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

29

→ High spec. supply air only units for cooling only applications

These units are single air stream (Supply fan only) with integrated mixing box (0-100% fresh air) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling mode only. Structure: Natural aluminum frame 40mm, Step panel 42mm with mineral wool insulation (90 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm

Components in Order of the direction of air flow: 1) Mixing box with dampers including 1 x louver, 1 x flexible connection and factor fitted actuators, 2) Combined filter section G4 pre filter F7 bag filter with factory mounted

differential pressure gauge and hinged door, 3) Section for factory mounted expansion valve kits EKEXV4) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 5) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 6) Empty section, 7) Sound attenuator 500 mm,8) F9 bag filter with factory mounted differential pressure gauge and hinged door,9) Flexible connection, 10) 150 mm base frame

Air flow m3/h 2.000 3.000 4.000 6.000 8.000 10.000 12.000

Width mm 950 1000 1150 1350 1550 1650 1650Height mm 800 930 950 1050 1050 1250 1300length mm 4820 4980 4970 5210 5310 5780 5770Weight kg ~ 500 ~ 570 ~ 650 ~ 780 ~ 860 ~ 1080 ~ 1170cooling capacity total kW 20,6 28,8 40,7 58,70 83,40 100,30 117,30cooling capacity sensible kW 10,9 16,4 22 32,90 43,40 55,20 65,70external static pressure Pa 450 450 450 450 450 450 450max. Power input fan kW 1,50 2,20 3,00 4,00 5,50 7,50 11,00Price HUf 5.509.400,– 5.755.600,– 6.899.100,– 7.499.900,– 8.986.900,– 10.548.400,– 10.825.200,–

Included VrV connection kit 1 x eKeXV2001 x eKeQmcB

1 x eKeXV2501 x eKeQmcB

2 x eKeXV2002 x eKeQmcB

2 x eKeXV2502 x eKeQmcB

3 x eKeXV2503 x eKeQmcB

4 x eKeXV2004 x eKeQmcB

4 x eKeXV2504 x eKeQmcB

capacity index 1 x 184 1 x 257 2 x 182 2 x 262 3 x 248 4 x 224 4 x 262

conditions: outside air: Summer 35 °c/50% r.H.; Supply air: Summer 19 °c1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel3) eKeXVs mounted inside Air Handling unit. eKeQmcB mounted inside control panel4) maximum connection ratio (cr) of the total VrV system: 110%5) Sum of capacity Indexes of eKeXVs must not exceed 30% when used in a system with other indoor units

PLUG and PLAY VRV® connection AHU

Page 30: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

30

→ Standard spec. supply and return air units for cooling / heating applications

These units are double air stream (Supply and Return fan) with integrated mixing box (0-100% fresh air), heat recovery system (Pleat heat exchanger or rotary wheel) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling and heating mode.

Structure: Natural aluminum frame 40mm, Flat panel 25mm with foam insulation (40 ÷ 50 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm

Components in Order of the direction of air flow: Supply air stream:1) Dampers section including 1 x louver, and factor fitted actuators,2) F5 bag filter with factory mounted differential pressure gauge and hinged door, 3) Heat recovery system (Pleat heat exchanger or rotary wheel),4) Mixing box with damper and factor fitted actuators,5) Direct expansion cooling coil with galvanized drain pan and droplet eliminator,6) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 7) Flexible connection, 8) 150 mm base frame

Return air stream:1) G4 flat filter with factory mounted

differential pressure gauge and hinged door,2) Return fan (incl. hinged door, porthole, drive screen, mounted

and wired light and on/off switch),3) Mixing box with damper and factor fitted actuators,4) Heat recovery system

(Pleat heat exchanger or rotary wheel),5) Dampers section including 1 x louver,

and factor fitted actuators

Air flow m3/h 2.000 3.000 4.000 6.000 8.000 10.000 12.000

Width mm 950 1000 1150 1350 1550 1650 2000Height mm 1450 1710 1750 1950 1950 2350 2350length mm 2960 3440 3190 3330 3730 3700 4020Weight kg ~ 550 ~ 680 ~ 700 ~ 900 ~ 1020 ~ 1270 ~ 1560cooling capacity total kW 20,6 28,8 40,7 58,70 83,40 100,30 117,30cooling capacity sensible kW 10,9 16,4 22 32,90 43,40 55,20 65,70Heating capacity total kW 11,25 16,50 21,30 32,26 44,40 57,91 78,31external static pressure Pa 450 450 450 450 450 450 450max. Power input supply fan kW 1,10 2,20 2,20 4,00 5,50 5,50 11,00max. Power input return fan kW 1,10 1,50 2,20 3,00 4,00 5,50 7,50Price HUf 7.491.400,– 7.920.600,– 8.883.800,– 9.860.000,– 11.309.400,– 13.381.300,– 14.544.100,–Included VrV connection kit 1 x eKeXV200

1 x eKeQmcB1 x eKeXV2501 x eKeQmcB

2 x eKeXV2002 x eKeQmcB

2 x eKeXV2502 x eKeQmcB

3 x eKeXV2503 x eKeQmcB

4 x eKeXV2004 x eKeQmcB

4 x eKeXV2504 x eKeQmcB

capacity index 1 x 184 1 x 257 2 x 182 2 x 262 3 x 248 4 x 224 4 x 262

conditions: outside air: Summer 35 °c/50% r.H.; Supply air: Summer 19 °c1) Height including 150 mm Base frame2) Width and Height without factory mounted control panel3) eKeXVs mounted inside Air Handling unit. eKeQmcB mounted inside control panel4) maximum connection ratio (cr) of the total VrV system: 110%5) Sum of capacity Indexes of eKeXVs must not exceed 30% when used in a system with other indoor units

PLUG and PLAY VRV® connection AHU

Page 31: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

31

→ High spec. supply and return air units for cooling / heating applications

These units are double air stream (Supply and Return fan) with integrated mixing box (0-100% fresh air), heat recovery system (Pleat heat exchanger or rotary wheel) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling and heating mode.

Structure: Natural aluminum frame 40mm, Step panel 42mm with mineral wool insulation (90 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm

Components in Order of the direction of air flow: Supply air stream:1) Dampers section including 1 x louver, and factor fitted actuators,2) Combined filter section G4 pre filter F7 bag filter with factory mounted differential pressure gauge and hinged door,3) Heat recovery system (Pleat heat exchanger or rotary wheel),4) Mixing box with damper and factor fitted actuators,5) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 6) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch),7) Empty section, 8) Sound attenuator 500 mm 9) F9 bag filter with factory mounted differential pressure gauge and hinged door 10) Flexible connection, 11) 150 mm base frame

Return air stream:1) F6 bag filter with factory mounted differential pressure

gauge and hinged door,2) Return fan (incl. hinged door, porthole,

drive screen, mounted and wired light and on/off switch),

3) Mixing box with damper and factor fitted actuators,4) Heat recovery system (Pleat heat exchanger or rotary

wheel),5) Dampers section including 1 x louver, and factor fitted actuators

Air flow m3/h 2.000 3.000 4.000 6.000 8.000 10.000 12.000

Width mm 950 1000 1150 1350 1550 1650 1650Height mm 1450 1710 1750 1950 1950 2350 2350length mm 4740 5170 4900 5050 5560 5580 5760Weight kg ~ 830 ~ 990 ~ 1070 ~ 1301 ~ 1520 ~ 1835 ~ 2230cooling capacity total kW 20,6 28,8 40,7 58,70 83,40 100,30 117,30cooling capacity sensible kW 10,9 16,4 22 32,90 43,40 55,20 65,70Heating capacity total kW 11,25 16,50 21,30 32,26 44,40 57,91 78,31external static pressure Pa 450 450 450 450 450 450 450max. Power input supply fan kW 1,50 2,20 3,00 4,00 5,50 7,50 11,00max. Power input return fan kW 1,10 1,50 2,20 3,00 4,00 5,50 7,50Price HUf 9.110.600,– 9.886.500,– 11.005.200,– 11.977.700,– 13.872.600,– 15.984.300,– 17.741.700,–Included VrV connection kit 1 x eKeXV200

1 x eKeQmcB1 x eKeXV2501 x eKeQmcB

2 x eKeXV2002 x eKeQmcB

2 x eKeXV2502 x eKeQmcB

3 x eKeXV2503 x eKeQmcB

4 x eKeXV2004 x eKeQmcB

4 x eKeXV2504 x eKeQmcB

capacity index 1 x 184 1 x 257 2 x 182 2 x 262 3 x 248 4 x 224 4 x 262

conditions: outside air: Summer 35 °c/50% r.H.; Supply air: Summer 19 °c1) Height including 150 mm Base frame2) Width and Height without factory mounted control panel3) eKeXVs mounted inside Air Handling unit. eKeQmcB mounted inside control panel4) maximum connection ratio (cr) of the total VrV system: 110%5) Sum of capacity Indexes of eKeXVs must not exceed 30% when used in a system with other indoor units

PLUG and PLAY VRV® connection AHU

Page 32: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

32

→ AIr cooler1-162 KW

On request we can offer you the most suitable air cooler for your application based on a brine/water solution.

→ AIr HAnDlInG UnIt500-140.000 m

3/H

On request we can offer you the most suitable air handling unit for your application.

• Air handling units for filtering, heating, cooling, humidifying, and air drying

• Air handling units with heat recovery • Air handling units for outdoor installation • Air handling units in hygienic execution for

hospital and clean room • Air handling units with indirect gas fired heating• Air handling units for swimming pool applications• Air handling units with higher air volumes

manufactured on request• Air handling units with thermal uncoupled frame

→ DrY cooler & conDenSer3-2.400 KW

On request we can offer you the most suitable dry cooler and condenser for your application.For correct selection we need following info:

• Heat rejection capacity (kW) or chiller type and working conditions

• Liquid inlet and outlet temperature (dry cooler)• Liquid type (dry cooler)• Condensing temperature (condenser)• Refrigerant type and number of circuits

(condenser)• Maximum/Minimum ambient temperature• Maximum sound level• Space restrictions

→ coolInG toWer70-9.200 KW

On request we can offer you the most suitable cooling tower for your application.For correct selection we need following info:

• Heat rejection capacity (kW) or chiller type and working conditions

• Liquid inlet and outlet temperature• Liquid type• Maximum/Minimum ambient temperature• Maximum sound level• Space restrictions

Page 33: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

33

→ comPreSSorInSPectIon/rePAIr/oVerHAUl

Remarksthe above is only valid for DAIKIn semi-hermetic compressors* excluding transport cost and other site related costs

Inspection

Inspection fee/compressor* on request

Repair

Repair cost/compressor* After inspection, on quotation base

Overhaul

Overhaul cost/compressor* on request

To extend the lifetime of your compressor, Daikin offers a compressor overhaul service as preventive maintenance.In case of broken compressor, Daikin can offer an inspection to determine whether the compressor is repairable or not. Based on the findings the broken parts will be replaced and the compressor will be restored into operational condition.

Compressor

Page 34: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

34

INVERTER

refr

iger

ant

Inve

rter

free

coo

ling

compressor efficiency version Sound version

Swin

g

Scro

ll

Scre

w

cent

rifug

al

Stan

dard

Hig

h

Prem

ium

Hig

h am

bien

t

Stan

dard

low

redu

ced

extr

a lo

w

capacity classes (kW)

cooling only 0 17.5 200 500 1,000 2,000

eWAQ~ADVP R-410A eWAQ~AcV3/AcW1 R-410A eUWA*~KBZW1 R-407C eWAQ~BA* R-410A eWAQ~DAYn R-410A eWAQ~e- R-410A eWAQ~f- R-410A eWAD~e- R-134a eWAD~D- R-134a eWAD~BZ R-134a eWAD~c- R-134a eWAD~cZ R-134a eWAD~cf R-134a Heat pump

0 17.5 200 500 1,000 2,000

eWYQ~ADVP R-410A eWYQ~AcV3/AcW1 R-410A eUWY*~KBZW1 R-407C eWYQ~BA* R-410A eWYQ~DAYn R-410A eWYD~BZ R-134a condensing unit

0 17.5 200 500 1,000 2,000

erAD~e- R-134a

Overview: Air cooled chiller portfolio

Page 35: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

35

refr

iger

ant

Inve

rter

free

coo

ling

compressor efficiency version Sound version

Swin

g

Scro

ll

Scre

w

cent

rifug

al

Stan

dard

Hig

h

Prem

ium

Hig

h am

bien

t

Stan

dard

low

redu

ced

extr

a lo

w

capacity classes (kW)

cooling only 0 17.5 200 500 1,000 2,000

eWAQ~ADVP R-410A eWAQ~AcV3/AcW1 R-410A eUWA*~KBZW1 R-407C eWAQ~BA* R-410A eWAQ~DAYn R-410A eWAQ~e- R-410A eWAQ~f- R-410A eWAD~e- R-134a eWAD~D- R-134a eWAD~BZ R-134a eWAD~c- R-134a eWAD~cZ R-134a eWAD~cf R-134a Heat pump

0 17.5 200 500 1,000 2,000

eWYQ~ADVP R-410A eWYQ~AcV3/AcW1 R-410A eUWY*~KBZW1 R-407C eWYQ~BA* R-410A eWYQ~DAYn R-410A eWYD~BZ R-134a condensing unit

0 17.5 200 500 1,000 2,000

erAD~e- R-134a

8,6 - 13,3

5.2~7.1

5.2~7.1

5.65-7.75

8.5~13.3

9.9-13.8

9.05~50.9

11.4~54.2

16.6~64.5

11.2~56.1

16.6~64.5

16.2~63.7

79.4-256

172~334

76.6-254

86.5-283

98~411

177~620

328~513

116~488

247~580

271~618

617~2,008

631~1,795

602~1,555

165~672

Page 36: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

36

Refri

gera

nt

Inve

rter

Free

coo

ling

Compressor Efficiency version Sound version

Swin

g

Scro

ll

Scre

w

Cen

trifu

gal

Stan

dard

Hig

h

Prem

ium

Hig

h am

bien

t

Stan

dard

Low

Redu

ced

Extr

a lo

w

Capacity classes (kW)

Water cooled chillers (Cooling only & Heating only) 0 17.5 200 500 1,000 2,000 9,000

EWWP-KBW1N R-407C

EWWD-J- R-134a

EWWD-G- R-134a

EWWD-I- R-134a

EWWD-H- R-134a

Water cooled chillers (Cooling only) 0 17.5 200 500 1,000 2,000 9,000

EWWQ-B- R-410A

Condenserless chillers 0 17.5 200 500 1,000 2,000 9,000

EWLP-KBW1N R-407C

EWLD-J- R-134a

EWLD-G- R-134a

EWLD-I- R-134a

Water cooled centrifugal chillers 0 17.5 200 500 1,000 2,000 9,000

EWWD-FZ R-134a

DWME R-134a

DWSCDWDC

R-134a

Brine (glycol) application

Star delta compressor starter

Thermal relays for compressors

Thermal relays for fans

Under/over voltage controller

Phase monitor device

Condenser coils with special

anti corrosion treatment

Flow switch for evaporator

(kit for field installation)

Victaulic connections

Rubber type ant vibration mounts

Evaporator heater

Main switch

Suction and discharge stop valves

on compressors

Dual set point possibility

Set point reset and demand limit possibility

General fault contact

Single pump

Twin pump

Total heat recovery

Partial heat recovery

Low ambient application

INVERTER

Overview: Portfolio Water cooled and Condenserless units

→ large chillers options and accessories summary

Depending on the type and size of chiller a wide range of options and accessories is available. E.g.

Page 37: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

37

Refri

gera

nt

Inve

rter

Free

coo

ling

Compressor Efficiency version Sound version

Swin

g

Scro

ll

Scre

w

Cen

trifu

gal

Stan

dard

Hig

h

Prem

ium

Hig

h am

bien

t

Stan

dard

Low

Redu

ced

Extr

a lo

w

Capacity classes (kW)

Water cooled chillers (Cooling only & Heating only) 0 17.5 200 500 1,000 2,000 9,000

EWWP-KBW1N R-407C

EWWD-J- R-134a

EWWD-G- R-134a

EWWD-I- R-134a

EWWD-H- R-134a

Water cooled chillers (Cooling only) 0 17.5 200 500 1,000 2,000 9,000

EWWQ-B- R-410A

Condenserless chillers 0 17.5 200 500 1,000 2,000 9,000

EWLP-KBW1N R-407C

EWLD-J- R-134a

EWLD-G- R-134a

EWLD-I- R-134a

Water cooled centrifugal chillers 0 17.5 200 500 1,000 2,000 9,000

EWWD-FZ R-134a

DWME R-134a

DWSCDWDC

R-134a

Power factor 0.9 correction device

A/V meter

Coil guards

Soft starter

Low noise version

Refrigerant Gauges

Coil guards

Cu/Cu condenser coils

High ESP fans

Cu/Ni heat exchanger

Dual pressure relieves safety valves

Different address card

Different bus communication gateways

(LonTalk, Bacnet, Modbus,…)

Chiller Sequencing Panel

Different Modems (fixed and GSM)

Plant Watch PRO monitoring system

Remote user interface

For the exact availability of the chiller which fits

best your application please get in contact with

your Daikin sales responsible.

Air cooled: eurovent certified up to 600kWWater cooled: eurovent certified up to 1500kWnominal cooling capacities are based on eurovent conditions:evaporator: 12°c/7°c — Ambient: 35°cnominal heating capacities are based on eurovent conditions:Ambient: 7°cDB/6°cWB — condenser: 40°c/45°c

12.9~194

120~568

165~602

302~1,503

368~1,212

300~4,500

16.7~249

142~681

209~743

405~1,866

432~1,416

600~9,000

379~2,156

12.1~62.4

109~528

160~524

327~1,416

314~1048

1,400~1,900

Daikin europe n.V. participates in the eurovent certification programme for Air conditioners (Ac), liquid chilling Packages (lcP), Air handling units (AHU) and fan coil units (fcU), check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com

Page 38: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

38

mentioned capacities, efficiency ratios, Sound power levels, Dimensions, Weights are indicative and valid under the following conditions:

Chillers

Air cooled units cooling 7 °c / 12 °c water 35 °c ambient tempHeating 40 °c / 45 °c water 7 °c ambient tempHeat recovery 7 °c / 12 °c water 40°c / 45°c heat recovery 35 °c ambient temp

Condenserless units cooling 7 °c / 12 °c water 45 °c condensing temp5 K subcooling

Water cooled units cooling 7 °c / 12 °c evaporator water 30 °c / 35 °c condenser waterHeating 7 °c / 12 °c evaporator water 40 °c / 45 °c condenser water

Rooftops

cooling: indoor temperature: 27 °c db / 19 °c wb outdoor temperature: 35 °cHeating: indoor temperature: 20 °c db outdoor temperature: 7 °c db / 6 °c wb

Condensing units

cooling: evaporation temperature: 6 °c outdoor temperature: 35 °c on-coil temperature: 27 °cDB / 19 °cWBHeating: condensing temperature: 46 °c outdoor temperature: 7 °c on-coil temperature: 20 °cDBGeneral:

evaporator superheat: 5K condenser sub-cool: 3K7,5 m equivalent refrigerant piping 0 m level difference

Fan coil units

cooling: room temperature DB/WB: 27 °c/19 °centering/leaving water temperature: 7 °c/12 °c

Heating: room temperature: 20 °centering water temperature: 50 °c (2-pipe,water flow rate same as for the cooling) / 70 °c (4-pipe, water temperature leaving 60°c)

Measuring conditions

Page 39: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

39

Commercial terms and conditions

I. GENERALour deliveries and services are exclusively subject to the following terms and conditions of sale and delivery, even if the customer provides otherwise. the ordering party’s counter-confirmations in reliance on his commercial terms and conditions or his terms and conditions of purchase apply only if they are consistent with these terms and conditions of delivery. Acceptance of the goods is in any event deemed to constitute an acknowledgment of our terms and conditions of sale and delivery. Any deviating modifications and amendments require our express consent and must be made in writing to be legally valid. our commercial terms and conditions can be found at www.daikin-ce.com.

II. OFFERour offers are without engagement and non-binding. Any information about dimensions, weights, technical data, quantities and delivery times is non-binding.

III. PLACING OF AN ORDER, CHANGE OF THE DELIVERABLE1. orders must be placed in writing (by letter, fax or email). We are deemed to have accepted an order not until

after we have confirmed in writing or actually executed that order. Any arrangement and agreement reached verbally and by phone must be confirmed in writing.

2. We reserve the right to rescind the contract even after having accepted an order if information we haveobtained about the customer’s liquidity in the meantime suggests that the customer will not be able to pay for the entire or for part of the order.

3. Having accepted an order, we also reserve the right to change and improve the service or deliverable, e.g. in respect of its type and design, to the extent the customer can be reasonably expected to accept such changes and improvements in consideration of our interests (e.g. delivery of an equivalent or more sophisticated device). Such changes and improvements are deemed approved in advance.

4. the customer’s cancellation or change of an entire or of part of an order requires our written consentand entitles us to charge the customer - in addition to the services already provided and costs accrued - a (cancellation) fee equal to 20  % of the order value and at least HUf  250. for certain product groups (e.g. multiple scroll, screw chiller), separate cancellation rules apply which can be found at www.daikin-ce.com.

IV. PRICES AND TERMS OF PAYMENT1. Prices are based on the price list, as amended from time to time, which is usually issued once a year. We reserve

the right to change prices also during a year.2. Prices are understood to be net prices without any taxes, duties or charges in the quoted currency, including

packaging, ex our forwarding warehouse, unless otherwise indicated. We will not take back packaging and packing material.

3. We will not accept any objections to invoices which are received more than two weeks after receipt of an invoice. Unless otherwise indicated, invoices are due net 30 days from the invoice date; the payment date is the date on which a payment is received by us. In case of late payment, we will charge default interest at a rate of 12% p.a. In case of default, we may also demand all costs related to the collection of our claim, including, without limitation, dunning and collection charges.

4. If payment by instalments has been agreed, the maturity date will be accelerated if the customer is in default in respect of only one instalment.

5. We may make deliveries dependent on advance payment.6. the customer may not withhold or set off payments in reliance on warranty or other claims.

V. DELIVERY TIME1. Indicated delivery times are non-binding and reference times only, although we endeavour to meet indicated

deadlines. the customer has no right to insist on compliance with a certain delivery time. As a consequence, delays in delivery will not entail any claims for damages and do not entitle the customer to rescind the contract. the same holds true if delivery deadlines are not met due to force majeure, strike or other events outside our control.

2. We will not accept penalty claims asserted by the customer under any circumstances.3. Partial deliveries are permitted.4. If the ordering party is in arrears on an earlier delivery, Daikin may withhold deliveries pending payment of the

earlier delivery and is not required to pay to the ordering party any damages in this respect.

VI. ACCEPTANCE OF DELIVERIES, TRANSFER OF RISK, DELAYED ACCEPTANCE1. Unless otherwise agreed, deliveries are made cIP (Incoterms 2010) to the named destination2. In principle, delivery cIP covers only minimum transport insurance. Additional transport insurance will be

purchased only if explicitly requested by customer and subject to a separate agreement and at the customer’s cost and expense.

3. the customer must immediately check deliverables received by him or directly by his customers for anytransport damage, and he must record any damage to the packaging or the device in the delivery note and shall refuse delivery towards the forwarding agent. If the customer finds out only later that goods are damaged, the customer shall report any such damage to us, immediately, in no case later than three working days after delivery; otherwise, any insurance claim may expire.

4. If the customer accepts goods with delay, we - notwithstanding our other rights - may charge the goods as delivered or may otherwise dispose of them @ setting a time limit. If we otherwise dispose of the goods, the delivery time will recommence on the day we receive the customer’s written request calling for delivery of the goods.

5. We may charge the customer for any costs incurred due to late acceptance, including, without limitation, any storage costs.

VII. RESERVATION OF TITLE1. We will retain title to goods delivered pending full payment of all claims arising from our business relationship

with the customer, even if the purchase price for specifically designated claims was paid. If our conditional goods are processed, we will acquire title to the new item without consideration. If the goods delivered by us are mixed, processed or combined with other items, the customer hereby assigns to us in proportion of the value of our invoices an ownership or co-ownership right of the combined or new item, both in respect of the interim and the final products.

2. the customer may resell goods delivered by us and the items created by processing, mixing or combining these only in the ordinary course of business. the customer hereby assigns to us any claims arising from such resale or from any other legal ground toward third parties, including, ancillary rights, in order to secure our - future - claims that may arise from our business relationship. the customer must record the assignment of these claims in his books not later than when the goods are resold.

3. Before having paid the purchase price of an item, the customer may resell that item only if he simultaneously informs the second buyer (end customer) that the resale proceeds have previously been assigned.

4. the customer may collect the assigned claims as long as he fulfils his payment obligations towards us according to the terms of the contract. the customer may not otherwise dispose of the conditional goods (e.g.: transfer of property by way of security, pledging).

5. the customer must immediately inform us of any attachment or other impairment of the conditional goods and/or the assigned claims and explain to the third party that we have retained title to those goods. Any related cost will be borne by the customer.

VIII. WARRANTY AND LIABILITYA. Unless otherwise agreed and to the exclusion of any further claims, we are liable for any defects and the absence of warranted qualities as follows:1. Unless otherwise indicated below, the warranty period is 36 months of the delivery date (delivery to the

forwarding agent). this does not affect the applicability of Section 924 of the Austrian civil code. 2. the customer may assert a warranty claim only if the equipment is both installed and put into operation

by Daikin or a company trained by Daikin according to the Daikin installation instructions and regularly maintained according to the Daikin service notes. refrigerating machines featuring screw-type compressors include a 12-month warranty claim only if the machine was put into operation by Daikin itself. In case of products designated “J&e Hall International for Daikin” the customer may assert an 18-month warranty claim. for “rotex” branded products generally a 24-month warranty period is valid except for following variations: 10 years for underfloor heating pipes and system plates, VA-piping and variosafe oil storage tanks. 5 years for solar panels, variosystem and highcube oil tanks and variocistern rainwater tanks. 3 years for HPSU heat pump solar unit and hot water storage tanks HYc, ScS and Sc.

3. In a warranty event, we undertake, at our election, to replace or repair the defective goods or components. the customer may not assert other warranty or guarantee claims whatsoever. labour cost, travel times or other costs will not be reimbursed.

4. no warranty and/or liability is accepted, unless the customer reports visible defects by giving written notice within 3 working days of delivery and other defects without delay after these have been discovered.

5. In addition to paragraphs 2 and 4, no warranty and/or liability is accepted for defects that have been caused by inadequate or improper use or treatment, failure to observe operating conditions or maintenance guideless, excessive use or inadequate operating facilities or substitute materials.

6. Unless we are granted the required time and opportunity to take all necessary warranty measures, we are released from any warranty claims and damages. If the customer continues to use defective goods, we warrant and/or are liable only for the original defect. We will not reimburse any cost of repairs which are carried out without our express prior consent. We disclaim any liability for the consequences of such repairs.

7. the warranty period for spare parts and other improvements is 6 months of delivery (delivery to the forwarding agent).

8. If a defect is remedied, the warranty period will not recommence for the replaced or repaired components.9. We may refuse to remedy defects as long as the customer is in default with his payment obligations. the

customer has no right to withhold payments, even if he gave justified notice of defects.10. If third-party products are delivered and installed, warranty is restricted to assigning the warranty claims we

may assert against the supplier of the third-party product. the customer may not assert any other warranty claims and may particularly not claim a price reduction.

B. We are liable for damage only if we demonstrably acted with intent or gross negligence. We disclaim any liability for slight negligence. We are particularly not liable for consequential damage (e.g. idle times due to wrong deliveries) and financial loss, lost profit, unachieved savings, loss of interest and any damage suffered from third-party claims against the customer, unless the foregoing is attributable to our intent or gross negligence. If damage is attributable to the defective condition of goods delivered by us, we are liable only to the extent the producer or upstream supplier is liable to us. our liability does in any case not exceed the invoice value of the incriminated goods.

IX. RETURNED GOODS1. Goods can be returned and exchanged only upon our express and written consent. We accept returned goods

only with a minimum net value of HUf 100.00 and a maximum net value of HUf 50,000.00 and only provided that those goods are not damaged, have not been used, are in original packaging and are fit for resale. In particular, returns of already installed units (including chillers) and returns of any made to order units as well as spare parts are not permitted.

2. the customer shall complete the “request for Goods return”-form (available at the DenV extranet, http:\\extranet.daikineurope.com) and send it to us to the fax number or email address provided by us within 10 calendar days after delivery, otherwise we will not accept the return.

3. Goods must be returned freight paid at the risk of customer to the destination indicated by us.4. In every case of a return, a maximum of 80% of the net price charged by us to the customer will

be credited. All standard returns will be subject to a restocking / administration charge of 20 % of the net price.5. All returns will be inspected by us. If goods are returned wrongly (i.e. not in compliance with paragraph 1.

above), we may refuse the returns and have them returned back to the customer at the customer’s risk and costs. Alternatively, we may charge a higher restocking / administration fee than the above mentioned 20%.

6. Any credit notes whatsoever will exclusively be set off against future deliveries.

X. PLACE OF JURISDICTION, APPLICABLE LAW 1. All disputes arising from or in connection with this Agreement shall be exclusively referred to the courts in

Vienna. 2. All contracts concluded by us and all disputes arising in connection with those contracts shall be governed

by and construed in accordance with Austrian law without giving effect to its conflict of law rules and the Un Sales convention.

XI. SEVERABILITYShould any term of these commercial terms and conditions or of the contract concluded between us and the customer be invalid or ineffective, this shall not affect the remaining terms hereof or thereof. Invalid terms shall be replaced by lawful terms which closest reflect the parties’ intent.

Campus 21, Europaring F12/402 · A-2345 Brunn am Gebirge, Austria phone +43 2236 32557, fax +43 2236 32557-900, [email protected], www.daikin-ce.com

the Daikin commercial terms and conditions are also available in the internet at http://www.daikin-ce.com.

Page 40: Applied Systems - Thermo D Comfort 2013... · 2013-08-08 · Air cooled chiller r-407c Scroll eUWA-KBZW 11-55 kW 6 ... The Daikin Commercial Terms and Conditions apply ... Unit size

ECPE

N13

dace

_AS

• Cop

yrig

ht D

aiki

n W

e re

serv

e th

e rig

ht fo

r prin

ting

erro

rs a

nd m

odel

cha

nges

.

The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

… top efficiency,low sound levels and flexible solutions for a wide range of applications

I n v e r t e r

N o n - i n v e r t e r

F r e e c o o l i n g

All year round…

The

EWAD~Cfamily

Daikin Hungary Kft.1117 Budapest Fehérvári út 84/a. 4. emelet Tel.: +36 / 1 / 464-4500 Fax: +36 / 1 / 464-4501 e-mail: [email protected] www.daikin.hu

Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com