0,350
1,05
Thermo’ClockSB04-15 T
Qm3/h
Hm
• Thermo’Clock SB04-15T
152 mm
THERMO’CLOCK
This circulating pump is only suitable for drinking water.Faster circulation in domestic hot water dis-tribution loops.• Industrial systems.• Domestic installations.
Instant hot water on demand, no sta-gnant water in the DHW loop.Ideal for floor-standing boilers
OPERATING RANGESFlow rates of up to: 0.35 m3/hMax. operating pressure: 10 barMin. intake pressure: 0.2 bar*Max. loop temperature: + 80°CCirculating pump temperature range: 0° to + 95°CMax. ambient temperature: + 40°CWater hardness (TH) : 35°fND of circulating pump ports: 15 (1”) * to + 65° C
SINGLE DOMESTICCIRCULATING PUMPS
Domestic hot water50 Hz
APPLICATIONS
BENEFITS OF THE RANGE
• Compact size- The Thermo’clock has an integral non-return valve and gate valve in a port-to-port distance of just 138 mm
• Extremely quiet- Special mechanical design • Reliable- New design prevents the build-up of lime scale
• Quick electrical connections- Plenty of room for electrical cables- Large gap between the three levers- «Earth - Live - Neutral» marked very clearly
- Easily accessible ports, for wiring of up to 2.5 mm2
• Easy to clean- Easily dismantled for any repairs to components in contact with water
N.T. No 123-4/ENG - Ed. 7/06-14
Certified
1
0,1 0,2 0,3 0,4 0 0
0
0
0 0
0,2
0,4
0,6
0,8
1,0
1,2
2,5 5 7,5 0,03 0,06 0,08 0,11
4
3
2
1
0,5 1 1,5
Qm3/h
Hm Imp.gpm
Ql/min
Ql/s
Hft THERMOCLOCK
2 pôles - 50Hz
Thermo’Clock SB 04-15 T
Thermo’Clock SB 04-15 T
THERMO’CLOCK
THERMO’CLOCK + POINTS+ Comfort- The accuracy of the thermostat guarantees hot water at the desired temperature on demand.
+ Safety- Consolidates the boiler’s role in the fight against legionnaire’s disease.
- Boilers increasingly incorporate an automatic thermal disinfection func-tion to kill off legionellosis bacteria. This operation entails raising the water temperature in the domes-tic hot water tank (to approx. 70°C). The Thermo’clock’s «Thermal Disinfection» function detects this operation and starts operating to facilitate the circulation of water in the loop.
- Automatic degumming
+ Savings Energy: - Reduced operating time- The Programmer allows the operation to be adapted to the users’ needs
Water: - Less wasted water- Instant hot water distribution Time:- No more waiting for hot water.
DESIGN• MotorSpeed: 2600 rpmSingle-phase winding: 230 VFrequency : 50 HzInsulation class: 155 (F)Conformity: NF EN 60.335.2.51 CE
BASIC CONSTRUCTIONMain parts MaterialPump housing BrassMotor casing PolypropyleneImpeller Composite materialRotor shaft CeramicBearings GraphiteRotor sleeve Stainless steelPump gasket Ethylene-propylene
SETTINGS• IconsTime menuSetting the current time.
Programmer menuPossible to programme up to3 operating time slots (On/Off) per 24 hr period.
Thermostat menu- Adjustment of the temperature setting.
- Possible to activate or deacti-vate the «thermal disinfection» function.
Display function- Alternating display of the current time and the minimum tempera-ture setting.
- If the «Thermal Disinfection» message is displayed, this func-tion is activated
• Simple and intuitive settings
Turn to select an icon or adjust a parameter
Press for > 3 sec: Select a menuQuick press: Confirm the setting of a parameter
HYDRAULIC PERFORMANCE
2 pole
2
Thermo'Clock
• Thermo’Clock SB04-15T
THERMO’CLOCK
INSTALLATION DIAGRAM AND CHOICE OF PUMPDomestic hot water distribution loop:• Max. temperature of loop: 60°C (according to DTU [French Codes of Practice]) and up to 80°C for thermal disinfection.
• Recommended max. flow rate of between 0.5 and 1 m/s.
• Circulating pump fitted on the return leg of the loop, after the drawing-off points.
Total length of pipework in the loop
1 to 10 drawing-off point(s)
0 to 35 m Zen Ô homeZen Ô home VThermo’Clock SB04-15 TNSB05-15B
36 to 75 m NSB10-15B76 to 100 m NSB15-15B
Choices given for information only, using the following criteria:- Insulation class 2 for pipework- DHW temperature: 60°C- Temperature decrease around the loop : 3°C- Ambient temperature: 20°C- Exterior temperature: - 7°C- Ø pipework in loop: 15/21
EXPLODED VIEW
3
126,4
8,4A
BG1”
16,642
24.5
77
41
99,4
71.65
66.35
31
7450
19
• Thermo’Clock SB 04-15T
Référence commande MOTEUR POMPE Raccordement surVitessetr/min
P1 nominaleW
IntensitéA
Massekg
Ø Gmm
tube à souder
tube fileté
Themo’clock SB 04 – 15 T 2600 22 0,25 2,1 G1 RU 2022 (brass) RU 1521 (brass)
THERMO’CLOCK
INSTALLATION POSITIONS FEATURESa) ElectricalAll types on 230 V - 50 Hz single-phaseStandard voltage:- tolerance 50 Hz ± 10 %
b) Fitting- Direct installation on horizontal or vertical pipework, on the return leg of the distribution loop, after the drawing-off points.
- Axis of motor always horizontal.
Connection to the system:According to the model:- soldered copper connectors (R) or screw-on brass connectors (RU brass) on copper pipework
- screw-on steel connectors (RU) on galva-nised steel pipework.
c) Packaging- Supplied with gaskets but without connectors.
d) Maintenance- Standard replacement of the appliance.
RECOMMENDED ACCESSORIES• Soldered connectors• Brass or steel pipe unions• Shut-off valves
ELECTRICAL AND DIMENSIONAL SPECIFICATIONS
A : Ball valveB : Non-return valve
Order reference MOTOR PUMP Connection ontoSpeed
rpmP1 rating
WCurrent
AWeight
kgØ Gmm
Soldered pipe
Threaded pipe
Themo’clock SB 04 – 15 T 2600 22 0,25 2,1 G1 RU 2022 (brass) RU 1521 (brass)
4