68
Application Information J. D. Gould Company, Inc. • P. O. Box 18128 • Indianapolis, IN 46218-0128 phone: (800) 63-GOULD • fax: (317) 547-5234 website: www.gouldvalve.com • email: [email protected]

Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

Application Information J. D. Gould Company, Inc. • P. O. Box 18128 • Indianapolis, IN 46218-0128

phone: (800) 63-GOULD • fax: (317) 547-5234 website: www.gouldvalve.com • email: [email protected]

Page 2: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

This Page Intentionally left blank

Page 3: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218 PRINTED IN USA

VALVE USES BY INDUSTRY

SOLENOID VALVES

4707 Massachusetts Ave. • P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

TYPICAL SOLENOID VALVE USES BY INDUSTRY

Valve Applications Recommended GOULD Valve AIR-POLLUTION CONTROL: Wash-down valves for Air Filters Types M-3V & Q Ultrasonic Cleaning Equipment Type M-3V AUTOMOTIVE: Various Assembly Plant Maintenance Uses Air/Water/Steam Valves Hydraulic Lifting Equipment Types Q4, BL, DL Tire-Tread Forming Equipment (Heating w/Steam & Water Cooling)

Types M-3V & M-1-3T

Auto/Truck Washes (Wash/ Rinse/ Valves) Types M-3V/Q-3V/B3-21 CONCRETE: Metered Batching Systems (Water Mixing) Types M-90 & Q-90 CRYOGENICS: Bulk Liquid Supply Valves Types M-3T-9, Q-3T-9 ELEVATORS: Down-leveling Valves Types BL & DL FOOD PROCESSING MACHINERY: Bottle Washers (Sanitizing) Types D, M-3V & Q-3V Poultry Feeding Systems (Water) Type M-3 V Preparation & Storage Types K-3T-9, KX-3T-9 Hen House Washdown Systems Type M-3V Bakeries: Pot/Pan Cleaning Spray Arms Spraying Oil on Top of Rolls Bun Warmers (Steam)

Types F, G, M-3V & M-1-3T Types F & G Type B3-19

In-Plant Bulk Transport (e.g. Vinegar, Milk, Bourbon, etc.)

Various Types (Primarily Types G, GX, K & KX)

GENERATING EQUIPMENT. Diesel/Gasoline Generating Systems Types Q-230 & K-230 Standby Generators (Water Coolant Systems) Type M4-3V

HOSPITAL EQUIPMENT Various Temperature Control Devices Types M-3V & M-1-3T Commercial Dishwashers Type M-3V-8 Various Gas/Air/Water Uses Variety of Types Boiler Feed Valves Types M-3V & M-1-3T

Page 4: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218 PRINTED IN USA

VALVE USES BY INDUSTRY

SOLENOID VALVES

4707 Massachusetts Ave. • P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

TYPICAL SOLENOID VALVE USES BY INDUSTRY (Continued)

Valve Applications Recommended GOULD Valve INDUSTRIAL MACHINERY Air Compressor/ Machine Coolant Systems Types M-3V Boiler Feed Units (Check Temperature Rating) Types M-3V & M-1-3T Deluge Systems (Smoke Stack Fire Prevention) Type M4-3V; Q4-3V & DST De-Ionized Water Systems Type KX-3EP-EP-62 Gravity Flow Systems Type J-3B Hydraulic Dock Lifts Types Q4-3V; BL & DL In-Plant Maintenance (Air/Water/Oil /Steam) Various Types (Consult Factory) Metal “Cold” treating Many “-9” Types Sandblasting Equipment (Wet or Dry Systems) Types M-3V Sequential Process Re-starting after Power Fails All Types Q-57 & K-57 Standby Generators (Coolant Systems) Types M4-3V [12V/D.C.] Steel Mills/Foundries - Quench Baths (Water Induction Systems) Types M-3V & Q-3V Tank Draining Type J-3B Television: Picture Tube (De-ionized H20) Type KX-3EP-EP-62 INSTRUMENTATION/GAUGE/CONTROLS: Automatic Gasoline/Diesel Fuel Pumps Type Q-230 Valves involved with Control Panels Various Types (Consult Factory) LAUNDRY & DRY CLEANING EQUIPMENT "Pants Toppers" - Steam valves Types B3-19 & BH-19 Dry Steam for Re-shaping drapes Type Q-1-3T Commercial Laundry Machines (Wash/Rinse Valves) Types Q-3V & Q1-3T MINING EQUIPMENT Dust Control Systems (Spray-down) Types QW & DST Water Management Types M-3V & Q-3V PAPER/PULP MILLS: Sawdust Control (Spray-down) Type M-3V Hydraulic Lifts Types Q4-3V; BL & DL Log Misting Systems Types M-3V & Q-3V Misc. Chemical Handling Types K-3T & KX-3T Pneumatic Systems Types M-3B & Q-3B Process Heating Types Q-1-3T, M-1-3T, K-1-3T

Page 5: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218 PRINTED IN USA

VALVE USES BY INDUSTRY

SOLENOID VALVES

4707 Massachusetts Ave. • P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

TYPICAL SOLENOID VALVE USES BY INDUSTRY (Continued)

Valve Applications Recommended GOULD Valve PETROCHEMICAL: Off Shore Oil Rigs K-3V-V-2 Gasoline, Diesel & Fuel Oil Distribution Q-230 & K-230 Pipeline Applications Various Types PLATING: Fill/Wash Cycle on Plating Tanks Types M-3V & Q-3V TRANSPORTATION: Aircraft Refueling Systems Types K-230, Q-230, EF-3V Railroad Refueling Systems Type QW-2 & QW-88-2 Aircraft De-Icing Systems Type Q-3V-76 Plane, Train & Automobile Wash Systems Types Q-3V, D-3T, M-3V, K-3T Train Switch De-Icers (Steam/LP Gas) Various Types (Consult Factory) RECREATION: Swimming Pools: Fill Water Type M-3V Whirlpools: Fill Water Type M-3V & B-3V RESTAURANT EQUIPMENT Commercial Dishwashers (Wash/Rinse) Type M-3V-8 (Dual Voltage) Pot/Pan Washers Type M-3V-8 & M-1-3T SEWAGE TREATMENTWATER PURIFICATION/FILTRATION/DESALINIZATION: Water Filtration Systems (Various Stages) Types M-3V; Q-3V & KX-3V Flow control for Ultraviolet Purifying Systems Types M-3V; Q-3V & KX-3V Gravity Flow Systems Type J-3B SPRINKLER & IRRIGATION SYSTEMS: Farm Sprinkler & Irrigation Systems All Types Lawn Sprinkler Systems All Types Not for Use with Fire Prevention Systems XXXXXX TEXTILE: Process Heating Types M-1-3T & Q-1-3T Sizing/ Drying/ Forming Nylon Stockings (Coolant System) Types QD & KD Hosiery Mills Types K & KX

Page 6: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

SOLENOID VALVES

4707 Massachusetts Ave. • P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

Valve Application Guide

GOULD SOLENOID VALVE APPLICATION GUIDE

This guide should help you outline your application and furnish us with the data necessary to supply a valve "tailor-made" for your job. Company Name ______________________________________________ Date _________________ Address ______________________________________________________________________________ Phone __________________ Fax ___________________ Email______________________________ Name & Title _________________________________________________________________________ 1. (a) Pipe Size ________________ (b) Type Gould Valve (see Literature) __________________ (All Standard Valves are 2-way, Globe Style, NPTF connections.) (c) Special Assemblies Required (See Literature) _____________________________________ Figure No. of Special Assembly __________________________________________________ 2. (a) Service ________________________________ (b) Temperatures _____________________ (c) Max. Pressure Differential ______________ (d) Min. Pressure Differential __________ (e) Normal Operating Pressure _____________ (f) Maximum Pressure ________________ 3. Required Flow of Medium: (a) ______________________________________________________ (b) at _________________ PSI with ________________ PSI drop. 4. Voltage: (a) A.C. _________________, Cycles __________________ (b) D.C. _________________, Rectified _______________ Battery _______________ (c) Voltage variation - Max. _____________________ Min. _____________________ 5. Operating Cycle: Continuous __________________ Intermittent ______________________ On Time ____________________ Off Time __________________________ 6. Quantities Required _______________________________________________________________

Page 7: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA REV. F

SOLENOID VALVES

4707 Massachusetts Ave. • P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

BULLETIN CP-1

FLOW DETAILAND

COIL SPECS

Cv FACTORS FOR GOULD SOLENOID VALVES

SLIDE RULES AVAILABLE TO CALCULATE FLOW OR PRESSURE DROP, CONSULT FACTORY.

1/4” = 1.2 1/8” = Pipe ID 1/8” = Pipe IDTYPE A SERIES: (Pipe Size) 3/8” = 2.0

TYPE K SERIES: (Pipe Size) 1/4” = Pipe ID

TYPE J SERIES: (Pipe Size) 1/4” = Pipe ID

3/8” = 2.9 3/8” = 2.91/4” = 1.9 1/2” = 3.0 1/2” = 3.0TYPE B SERIES:

(Pipe Size) 3/8” = 2.8 3/4” = 6.0 3/4” = 6.0 1/2” = 3.3 1” = 11.0 1” = 11.0 1-1/4” = 17.0

3/16” = 0.70 1-1/2” = 25.0 1/8” = 1.2 2” = 45.0

TYPE Q SERIES: (Pipe Size) 1/4” = 2.2

TYPE B3 SERIES: 1/4” or 3/8” NPT

(Orifice Size) 3/8” = 2.5 1/8” = 1.2 1/2” = 2.8

3/4” = 6.3 Type M SERIES:

(Pipe Size) 1/4” = 2.2 3/4” = 6.8TYPE D SERIES: (Pipe Size) 1” = 11.5 3/8” = 2.5 1” = 11.5

1-1/4” = 18.0 1/2” = 2.8 1-1/4” = 18.0 1-1/2” = 28.0 3/4” = 6.8 1-1/2” = 26.0 2” = 50.0 1” = 11.5 2” = 48.0 1-1/4” = 18.0 2-1/2” = 75.0

4” = 195.0 1-1/2” = 26.0 3” = 100.0TYPE EF SERIES: (Pipe Flange Size) 2” = 48.0

1/4” = 1.2

7/32” = 1.0 TYPES F & G:

1/8” - 3/8” (Orifice Size) 3/16” = 0.70

5/32” = 0.50 1/8” = 0.30

3/32” = 0.18 1/16” = 0.08 3/64” = 0.03

STANDARD PILOT ORIFICE/PRESSURE RATING FOR GOULD SOLENOID VALVES

TYPE M – AIR & WATER ORIFICE 1/8” 7/64” #45 5/64” DRILL PRESSURE 100 125 200 250 PSI

TYPE J – AIR & WATER

ORIFICE 3/32” 5/64” DRILL PRESSURE 125 250 PSI

ALL OTHER TYPES*

STANDARD COIL EXTRA STRONG COIL AIR (psi) WATER (psi) OIL (psi) ORIFICE AIR (psi) WATER (psi) OIL (psi)

200 100 75 1/8” 500 180 50 300 150 100 7/64” 220 100 500 200 150 3/32” 350 200

300 5/64” 450 300 500 1/16” 600 500 3/64” 1200 1200

NOTE: For Steam Orifice Sizes – Use Air to Maximum of 200 psi. *Except Type KX – CONSULT FACTORY

Page 8: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

BULLETIN CP-1

PRINTED IN USA REV. F

COIL SPECIFICATIONS FOR GOULD SOLENOID VALVES

(For non-standard voltages or 50hz applications consult factory • *denotes value when used in Type J valves)

VALVE TYPE VOLTAGE COIL # INSULATION CLASSMAX. FLUID TEMP.

INRUSH Current (A)

HOLDING Current (A) WATTS

120 /60 0 .75 0 .35 18M 120 /240 /60 96012 N450 °F 240 /60 0 .38 0 .18 18 120 /60 0 .72 0 .26 14B3 120 /240 /60 75012 F300 °F 240 /60 0 .36 0 .13 14

M 12 /60 H12A N 450°F B3 12 /60 75H12 F 300 °F 8 .40 4 .20 18

A l l O the r 12 /60 1547 F 300 °F 8 .40 4 .20 18 A l l O the r 12 /60 2540 N 450°F 8 .40 4 .20 20

M 24 /60 H24A N 450°F 3 .10 1 .54 17 B3 24 /60 7507 F 300 °F 3 .60 1 .80 14 B3 24 /60 75H7 N 450°F 15

A l l O the r 24 /60 L555 F 300 °F 4 .60 2 .30 20 A l l O the r 24 /60 1144 N 450°F 1 .90 0 .95 18 A l l O the r 24 /60 1347 N 450°F 5 .50 2 .60 /3 .25* 24 /44* Al l O the r 55 /60 L757 F 300 °F 1 .30 0 .64 18

M 120 /60 H1A N 450°F 0 .70 0 .35 17 B3 120 /60 7501 F 300°F 0 .72 0 .26 14 B3 120 /60 75H1 N 450°F 0 .72 0 .36 15

A l l O the r 120 /60 1138 F 300 °F 0 .64 0 .32 14 A l l O the r 120 /60 1386 F 300 °F 1 .00 0 .60 18 A l l O the r 120 /60 1143 N 450°F 0 .84 0 .42 /0 .65* 20 /44*

M 240 /60 H2A N 450°F 0 .36 0 .18 18 B3 240 /60 7502 N 450°F 0 .36 0 .13 15 B3 240 /60 75H2 N 450°F 0 .36 0 .13 15

A l l O the r 240 /60 1139 F 300 °F 0 .32 0 .16 14 A l l O the r 240 /60 1223 /1224 F 300 °F 0 .50 0 .30 26 A l l O the r 240 /60 1142 N 450°F 0 .42 0 .21 /0 .33* 20 /44*

M 480 /60 H3A N 450°F 0 .22 0 .11 19 B3 480 /60 7503 F 300 °F 0 .18 0 .07 14

A l l O the r 480 /60 1140 F 300 °F 0 .16 0 .08 14 A l l O the r 480 /60 1387 F 300 °F 0 .25 0 .15 26 A l l O the r 480 /60 1141 N 450°F 0 .20 0 .10 /0 .17* 20 /44* Al l O the r 550 /60 1797 F 300 °F 0 .20 0 .10 26 A l l O the r 550 /60 1145 N 450°F

M 6 DC 6HD N 450°F - B3 6 DC 6750 F 300 °F - 4 .00 24

A l l O the r 6 DC 1347 F 300 °F - 4 .20 24 M 12 DC 12HD N 450°F - 1 .80 22 B3 12 DC 75H12 N 450°F - B3 12 DC 12750 F 300 °F - 2 .00 24

A l l O the r 12 DC 1314 F 300 °F - 2 .00 24 A l l O the r 12 DC 1314H N 450°F - 2 .00 /2 .25* 24 /27* Al l O the r 18 DC 1751 N 450°F - 1 .40 25

M 24 DC 24HD N 450°F - 1 .00 24 B3 24 DC 24750 F 300 °F - 1 .00 24

A l l O the r 24 DC 1315 F 300 °F - 1 .00 24 A l l O the r 24 DC 1751 N 450°F - 1 .85 /1 .30* 48 /31* Al l O the r 32 DC 1149 F 300 °F - 0 .75 24 A l l O the r 32 DC 1751 N 450°F - 2 .40 76

M 48 DC 48HD N 450°F - B3 48 DC 48750 F 300 °F - 0 .50 24

A l l O the r 48 DC 1542 N 450°F - M 115 DC 115HD N 450°F - 0 .26 30 B3 115 DC 115750 F 300 °F - 0 .20 24

A l l O the r 115 DC 1349 F 300 °F - 0 .17 24 A l l O the r 115 DC 1695 N 450°F - 0 .25 28

M 230 DC 230HD N 450°F - B3 230 DC 23750 F 300 °F - 0 .10 24

A l l O the r 230 DC 1350 F 300 °F - 0 .09 24 Al l O the r 230 DC 1696 N 450°F - 0 .12 28

Page 9: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218 PRINTED IN USA

CORROSION RESISTANCE

SOLENOID VALVES

4707 Massachusetts Ave. • P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

CORROSION RESISTANCE RATING CHART

Bron

ze

Alum

inum

Car

bon

Stee

l

303

SS

316

SS

Buna

N

Neo

pren

e

PTFE

Nyl

on

Flou

roca

rbon

Bron

ze

Alum

inum

Car

bon

Stee

l

303

SS

316

SS

Buna

N

Neo

pren

e

PTFE

Nyl

on

Flou

roca

rbon

Acetaldehyde 1 1 4 4 1 4 Boric Acid 1 1 4 1 1 1 1 1 1 1 Acetic Acid, Pure 1 1 2 2 1 1 4 Brine 2 2 1 1 1 1 1 Acetic Anhydride 2 1 1 1 2 2 1 1 4 Bromine, Dry 2 4 4 4 4 4 4 1 2 Acetone 1 1 1 1 1 2 2 1 1 4 Bromine, Wet 4 4 2 Alcohols 1 2 1 1 2 2 1 1 1 Butadiene 1 1 1 1 3 1 1 1 Alum 2 3 3 1 1 1 1 1 1 Butane 1 1 1 3 2 1 1 Alumina 1 1 1 1 1 1 Butylene 1 4 3 1 1 Aluminum Chloride 2 4 4 4 4 1 1 1 1 1 Buttermilk 3 1 1 1 1 1 1 Aluminum fluoride 4 3 3 1 1 1 1 1 Butyl Acetate 1 1 4 4 1 4 Aluminum Hydroxide 1 1 1 1 1 1 1 1 Butyl Alcohol 1 3 1 1 1 1 1 1 Aluminum Sulfate 2 3 4 3 3 1 1 1 1 1 Butyric Acid 1 1 3 1 1 1 1 4 Amines 1 1 2 2 1 1 4 Calcium Bisulphite 2 3 4 2 1 1 1 1 1 2 Ammonia (Anhydrous Liquid) 4 1 1 2 2 1 1 4 Calcium Carbonate 1 1 1 1 1 1 1 1 1 Ammonium Bicarbonate 1 1 1 1 1 1 1 Calcium Chloride 2 3 1 1 1 1 1 1 1 1 Ammonium Chloride 4 3 4 3 1 1 1 1 1 Calcium Hydroxide 1 3 1 1 1 1 1 1 1 1 Ammonium Diphosphate 1 1 1 1 1 1 Calcium Sulphate 1 1 3 1 1 1 1 1 1 Ammonium Hydroxide 1 1 1 1 1 1 2 Calgon 1 1 1 1 1 1 1 Ammonium Monophosphate 4 3 1 1 1 1 1 1 Caliche Liquor 1 1 1 1 1 Ammonium Nitrate 4 3 1 1 1 1 1 1 1 2 Carbolic Acid 1 1 1 1 4 3 1 1 2 Ammonium Phosphate 3 1 1 1 1 1 1 1 1 Carbon Disulphide 2 1 1 1 1 4 4 1 1 1 Ammonium Sulphite 3 3 1 1 1 1 1 1 1 1 Carbon Tetrachloride 1 3 1 1 1 4 1 1 1 Amyl Acetate 1 1 3 3 1 3 4 1 4 Carbonated Water 2 1 1 1 1 1 1 1 Amyl Alcohol 1 3 3 1 1 1 Castor Oil 1 1 1 1 1 1 1 1 1 1 Amyl Chloride 1 1 2 2 1 3 China Wood Oil (Tung) 1 1 1 1 1 1 1 1 Aniline 4 1 1 1 1 1 2 Chlorinated Solvents 1 4 1 2 2 1 1 1 1 2 Aniline Dye 3 3 1 3 3 1 2 Chloracetic Acid 2 4 4 4 4 3 3 1 1 1 Antimony Trichloride 4 4 2 2 1 1 1 Chloroform 4 4 1 1 4 4 1 1 3 Arsenic Acid 1 1 1 1 1 1 Clorox 1 1 1 1 1 Asphalt 1 1 1 1 1 1 Chromic Acid 1 1 4 4 1 3 Barium Carbonate 1 1 1 1 1 1 1 1 Citric Acid 2 1 4 2 1 1 1 1 1 1 Barium Chloride 2 4 1 1 1 1 1 1 1 Coffee 1 1 1 1 1 1 Barium Hydroxide 1 4 1 1 1 1 1 1 Copper Chloride 3 4 4 1 1 1 1 1 Barium Sulphate 1 1 1 1 1 1 1 Copper Nitrate 3 1 1 1 1 1 1 1 Barium Sulphide 1 1 1 1 1 1 Copper Sulphate 2 4 4 3 1 1 1 1 1 1 Beer 2 1 1 1 2 1 1 1 1 1 Creosote 1 1 1 1 4 4 1 4 1 Beet Sugar Liquid 1 1 1 1 1 1 1 1 1 1 Cresylic Acid 2 1 3 1 1 3 4 1 4 2 Benzene (Benzol) 1 1 1 1 1 4 4 1 1 3 Cyclohexamine 1 1 1 1 Black Sulphate Liquor 3 1 1 1 1 1 Diacetone 3 3 3 1 4 Bleaching Powder-Wet 2 2 1 1 1 1 Diamylamine 1 1 1 4 Borax 1 3 1 1 1 1 1 1 1 1 Dichloroethane 3 3 4 1 2

KEY: 1 – Excellent 2- Good 3 – Fair 4 – Unsatisfactory Blank - Insufficient Data

NOTE: When using this table . . . Please remember that in any given case many factors such as solution concentration, temperature, degree of agitation and presence of Impurities influence the rate of corrosion. We suggest that these ratings be used

as a first approximation for your requirements rather than the final answer.

Page 10: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218 PRINTED IN USA

CORROSION RESISTANCE

SOLENOID VALVES

4707 Massachusetts Ave. • P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

CORROSION RESISTANCE RATING CHART

Bron

ze

Alum

inum

Car

bon

Stee

l

303

SS

316

SS

Buna

N

Neo

pren

e

PTFE

Nyl

on

Flou

roca

rbon

Bron

ze

Alum

inum

Car

bon

Stee

l

303

SS

316

SS

Buna

N

Neo

pren

e

PTFE

Nyl

on

Flou

roca

rbon

Dichloropentane 3 4 1 1 2 Glucose 1 1 1 1 1 1 1 1 1 1 Diesel Oil, Light 1 3 1 1 1 Glue (acid) 1 1 3 1 1 1 1 1 1 Diethanolamine 1 1 1 1 4 Glycerin or Glycerol 1 1 1 1 1 1 1 1 1 1 Diethyl Sulfate 2 2 1 1 Grease 1 2 1 1 Diethyl benzene 4 4 1 3 Heptane 1 1 1 1 1 1 1 Diethylene Glycol 1 1 1 1 1 1 1 Hydrazine, Hydrate 1 1 4 Dimethyl Phthalate 2 2 1 1 Hydrobromic Acid 3 4 4 4 4 1 1 1 2 Dipentene 1 1 1 1 Hydrochloric Acid 4 4 4 1 1 4 Diphenyl 1 1 1 Hydrocyanic Acid 4 1 3 1 1 1 1 1 1 1 Dowtherm 1 4 4 1 1 Hydrofluoric Acid 3 4 4 4 4 4 4 2 Enamel 1 1 1 1 1 2 Hydrofluosilicic Acid 1 4 4 1 1 1 2 Ethanolamine 1 1 1 1 4 Hydrogen Gas (cold) 1 1 1 1 1 1 1 Ethers 1 1 1 1 1 4 4 1 4 Hydrogen Gas (hot) 3 1 1 1 1 1 1 Ethyl Acetate 1 3 1 1 3 4 1 1 4 Hydrogen Peroxide 2 1 4 3 3 1 1 1 1 3 Ethyl Benzene 3 4 1 1 2 Hydrogen Sulphide (dry) 3 1 1 1 1 1 1 1 1 1 Ethyl Cellulose 1 1 1 1 Hydrogen Sulphide (wet) 3 1 4 2 1 1 3 1 1 Ethyl Chloride 1 1 3 1 1 1 1 1 1 Hypochlorite, Sodium 1 4 1 1 1 Ethyl Sulphate 1 1 1 1 1 Hypochlorous Acid 1 1 1 1 1 Ethylene Dichloride 4 4 1 1 3 Ink 3 1 1 3 1b Ethylene Glycol 2 1 1 1 1 1 2 1 1 1 Iodine, wet 4 4 4 2 1 1 1 Ethylene Oxide 1 4 4 1 1 3 lodoform 1 1 1 1 3 Fatty Acids 1 1 1 1 2 1 1 1 Isobutane 4 1 1 3 1 1 Ferric Chloride 4 4 4 4 4 1 1 1 1 1 Isooctane 1 3 1 1 Ferric Nitrate 4 1 1 1 1 Isopropyl Acetate 4 4 1 4 Ferric Sulphate 4 4 4 4 3 1 1 1 1 1 Isopropyl Alcohol 1 1 1 1 1 Ferrous Chloride 2 4 4 1 1 1 1 1 Isopropyl Ether 1 2 1 4 Ferrous Sulphate 2 1 1 1 1 1 1 1 1 Kerosene 1 1 1 1 3 1 1 1 Fish Oils 1 2 1 1 1 Ketchup 1 1 1 1 1 1 1 Fluoboric Acid 1 1 1 1 1 1 Ketones 4 4 1 1 4 Fluosilicic Acid 1 1 1 3 Lacquers (& solvents) 1 1 3 1 3 4 1 1 4 Formaldehyde 1 1 3 1 1 1 1 1 1 4 Lactic Acid 2 4 1 1 4 4 1 1 2 Formic Acid 3 4 4 2 3 1 1 1 1 2 Lime Slurries 1 1 1 1 1 1 Freon 1 1 3 3 2 1 1 1 2a Lime, sulfur 3 1 1 1 1 1 Fruit Juices 2 3 3 1 1 1 1 1 Linseed Oil 1 1 1 1 1 1 4 1 1 1 Fuel Oil 1 1 1 1 2 1 1 1 Lubricating Oils (Ref) 1 1 1 3 1 Fumaric Acid 1 1 1 2 Magnesium Chloride 2 4 3 4 1 1 1 1 1 1 Furfural 1 1 1 1 1 4 2 1 4 Magnesium Hydroxide 1 4 1 1 1 1 1 1 1 1 Gallic Acid 1 1 1 1 1 1 1 2 Magnesium Sulphate 2 2 1 1 1 1 1 1 1 1 Gasoline, Refined 1 1 1 1 1 4 2 1 1 1 Maleic Acid 1 1 1 1 1 1 2 Gelatin 1 1 3 1 1 1 1 1 1 Malic Acid 2 3 2 1 1 1 1 3

KEY: 1 – Excellent 2- Good 3 – Fair 4 – Unsatisfactory Blank - Insufficient Data

NOTE: When using this table . . . Please remember that in any given case many factors such as solution concentration, temperature, degree of agitation and presence of Impurities influence the rate of corrosion. We suggest that these ratings be used

as a first approximation for your requirements rather than the final answer.

a Good for all Freon except #22 which is (4). b Good unless aniline base ink.

Page 11: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218 PRINTED IN USA

CORROSION RESISTANCE

SOLENOID VALVES

4 7 0 7 M AS S AC H U S E T T S AV E . P . O . B O X 1 8 1 2 8

I N D I AN AP O L I S , I N D I AN A 4 6 2 1 8 - 0 1 2 8 P H O N E : 3 1 7 5 4 7 - 5 2 8 9

CORROSION RESISTANCE RATING CHART

Bron

ze

Alum

inum

Car

bon

Stee

l

303

SS

316

SS

Buna

N

Neo

pren

e

PTFE

Nyl

on

Fluo

roca

rbon

Bron

ze

Alum

inum

Car

bon

Stee

l

303

SS

316

SS

Buna

N

Neo

pren

e

PTFE

Nyl

on

Fluo

roca

rbon

Malt Beverages 1 1 1 1 1 Phosphoric Acid 3 4 3 2 2 1 1 1 Mayonnaise 3 1 1 1 1 1 Phthalic Acid 3 3 1 1 2 Melamine Resins 4 4 2 2 1 1 1 Picric Acid 4 1 1 1 1 3 1 1 2 mercuric Chloride 4 4 4 1 1 1 1 Pine Gum-Pine Oil 1 1 1 1 1 1 Mercury 4 4 1 1 1 1 1 1 1 1 Pitch 3 3 1 1 1 Mercury Salts 4 4 4 1 1 1 1 1 Potassium Alum. 1 1 1 1 1 Methyl Alcohol 1 4 1 1 1 1 1 1 1 2 Potassium Bicarbonate 1 1 1 1 Methyl Cellosolve 4 4 1 1 3 Potassium Bisulphite 1 1 1 1 1 Methyl Chloride 1 4 1 1 1 3 4 1 1 3 Potassium Bromide 3 3 2 1 1 1 1 Methyl Ethyl Ketone 4 4 1 1 4 Potassium Carbonate 2 4 1 1 1 1 1 1 1 Methyl Formate 2 2 1 1 2 Potassium Chlorate 1 1 1 1 1 1 1 Methyl Isobutyl Ketone 4 4 1 4 Potassium Chloride 3 1 1 3 1 1 1 1 1 1 Milk 1 1 1 1 1 1 1 1 1 1 Potassium Chromate 1 1 1 1 1 1 Mine Waters (acid) 3 1 1 1 1 1 Potassium Cyanide 4 1 1 1 1 1 1 1 1 Mineral Oil 1 1 1 1 1 1 1 1 Potassium Diphosphate 1 1 1 1 1 1 1 Molasses 1 1 1 1 1 1 1 1 Potassium Ferricyanide 1 1 1 1 Monochloracetic Acid 3 3 1 4 Potassium Hydroxide 2 4 1 1 1 1 1 1 1 Monochlorobenzene 4 4 1 2 Potassium Iodide 1 1 1 1 1 Naphtha 1 1 1 3 1 1 1 Potassium Monophosphate 1 1 1 1 1 1 1 Naphthalene 2 1 1 4 4 1 1 1 Potassium Permanganate 1 1 1 1 1 1 1 Natural Gas 1 1 1 1 1 1 1 1 Potassium Phosphate 1 1 1 1 1 Nickel Chloride 4 4 3 3 1 1 1 1 1 Potassium Sulphate 2 1 1 1 1 1 1 1 1 1 Nickel Nitrate 2 1 1 1 1 1 Potassium Triphosphate 1 1 1 1 1 1 1 Nickel Sulphate 2 1 1 1 1 1 Prestone 1 2 1 1 1 Nitric Acid 4 4 4 4 1 4 4 Producer Gas 1 1 1 1 1 1 Nitrobenzene 1 1 1 4 1 3 Propane Liquefied 1 1 1 1 1 1 1 1 Oleic Acid 2 1 1 2 2 1 1 2 Pyrogallic Acid 3 1 1 2 Oleum 1 3 1 4 4 1 1 Pyridine 4 4 4 1 4 Organic Acids 1 4 3 Rayon Spin Bath 3 1 1 Organic Esters 1 1 4 Resorcinol 1 2 Oxalic Acid 2 1 3 1 1 1 1 1 1 3 Rosin Emulsion 1 1 1 1 Oxygen cold 1 1 1 1 1 1 1 1 1 Salicylic Acid 1 1 1 1 1 Oxygen hot 1 1 1 1 4 4 4 1 Sea Water 2 1 1 1 1 1 1 Palmitic Acid 2 1 1 1 2 2 1 1 2 Sewage 3 3 3 1 1 1 1 Paraffin 1 1 3 1 1 1 Shellac 1 2 Paraformaldahyde 2 2 1 4 Silicon Tetrachloride 4 1 Paraldehyde 2 2 1 4 Silver Bromide 1 1 Parez 607 4 4 4 1 Silver Nitrate 4 1 1 3 3 1 1 1 Pentane 1 1 1 1 Soap Liquids 1 1 1 1 1 3 1 1 1 Phenol 1 1 1 2 2 1 4 2 Sodium Acetate 1 1 1 2 2 1 1 4

KEY: 1 – Excellent 2- Good 3 – Fair 4 – Unsatisfactory Blank - Insufficient Data

NOTE: When using this table . . . Please remember that in any given case many factors such as solution concentration, temperature, degree of agitation and presence of Impurities influence the rate of corrosion. We suggest that these ratings be used

as a first approximation for your requirements rather than the final answer.

Page 12: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218 PRINTED IN USA

CORROSION RESISTANCE

SOLENOID VALVES

4 7 0 7 M AS S AC H U S E T T S AV E . P . O . B O X 1 8 1 2 8

I N D I AN AP O L I S , I N D I AN A 4 6 2 1 8 - 0 1 2 8 P H O N E : 3 1 7 5 4 7 - 5 2 8 9

CORROSION RESISTANCE RATING CHART

Bron

ze

Alum

inum

Car

bon

Stee

l

303

SS

316

SS

Buna

N

Neo

pren

e

PTFE

Nyl

on

Fluo

roca

rbon

Bron

ze

Alum

inum

Car

bon

Stee

l

303

SS

316

SS

Buna

N

Neo

pren

e

PTFE

Nyl

on

Fluo

roca

rbon

Sodium Acid Sulfate 1 1 1 1 1 Sugar Liquids 1 1 1 1 1 1 1 Sodium Aluminate 1 1 1 1 1 1 1 Sulphur, Molten 4 1 1 1 1 1 1 1 1 1 Sodium Bicarbonate 2 1 3 1 1 1 1 1 1 1 Sulphur Chloride 1 4 4 4 4 1 1 1 Sodium Bisulfate 3 2 4 1 1 1 1 1 1 1 Sulphur Dioxide, Dry 3 1 1 1 1 1 1 1 1 1 Sodium Bisulphite 2 1 3 1 1 1 1 1 1 Sulphur Dioxide, Wet 4 1 2 1 1 1 Sodium Borate 1 1 1 1 1 Sulphur Trioxide, Dry 1 1 4 1 1 Sodium Bromide 2 1 1 1 Sulphuric Acid 2-40% 3 2 4 4 2 4 1 1 3 1 Sodium Carbonate 1 4 3 1 1 1 1 1 1 1 Sulphuric Acid 40% 3 2 4 4 2 4 1 1 3 1 Sodium Chlorate 2 1 1 1 Sulphuric Acid 93-98% 4 4 3 2 2 4 4 1 4 2 Sodium Chloride 3 2 1 2 1 1 1 1 1 1 Sulphurous Acid 4 2 1 3 1 2 2 1 2 1 Sodium Chromate 1 1 1 1 1 1 Talc Slurry 1 1 1 1 1 Sodium Cyanide 4 4 1 1 1 1 1 1 1 1 Tallow, Molten 1 1 1 1 1 Sodium Dichromate 1 1 1 1 1 Tannic Acid 1 4 1 1 1 1 1 1 1 Sodium Fluoride 1 1 1 1 Tannin 1 1 1 1 1 Sodium Hydroxide 4 4 1 1 1 1 1 1 1 4 Tar 1 1 1 3 3 1 1 1 Sodium Hypochlorite 4 3 2 3 3 1 1 3 Tartaric Acid 1 1 4 3 1 1 1 1 1 1 Sodium Monophosphate 2 1 3 1 1 1 1 1 1 Tetraphosphoglucosate 1 1 1 1 Sodium Nitrate 2 1 1 1 1 1 1 1 1 1 Thiamin Hydrochloride 1 1 Sodium Nitrite 1 1 1 1 Toluene 1 1 1 1 1 3 4 1 1 3 Sodium Orthosilicate 1 1 1 1 1 Trichlorethylene 1 1 1 1 4 4 1 Sodium Perborate 1 1 1 1 1 1 1 Trichloroacetic Acid 2 2 1 3 Sodium Peroxide 3 1 1 1 1 1 1 1 1 Trichloroethylene 1 1 1 1 3 4 1 3 Sodium Phosphate 1 1 1 Triethanolamine 2 1 1 1 1 4 Sodium Polyphosphate 1 1 1 1 1 1 1 Triethylamine 1 1 1 1 1 4 Sodium Pyrophosphate 1 1 1 1 1 Trisodium Phosphate 4 1 1 1 1 1 Sodium Resinate 1 1 1 1 1 Turpentine 3 1 1 1 4 2 1 1 1 Sodium Silicate 1 4 1 1 1 1 1 1 1 1 Varnish 1 1 1 3 1 1 1 1 Sodium Sulphate 2 1 1 1 1 1 1 1 1 1 Vinegar 2 3 3 3 1 1 1 1 1 1 Sodium Sulphide 3 4 1 3 1 1 1 1 1 1 Water Acid Mine 4 1 1 1 1 1 Sodium Sulphite 2 2 1 1 1 1 1 1 1 Water Salt 3 2 4 2 1 1 Sodium Tetraborate 1 1 1 1 1 1 1 Whiskey 2 2 4 1 1 1 1 1 1 1 Sodium Tetraphosphate 1 1 1 1 1 Wine 2 2 4 1 1 1 1 1 1 1 Sodium Thiosulphate 3 4 1 1 1 1 1 1 1 Xylene 1 1 1 1 4 4 1 1 3 Sodium Triphosphate 1 1 1 1 1 1 1 Zeolite 1 1 1 1 1 Soybean Oil 1 1 1 1 1 1 Zinc Acetate 1 1 1 1 1 Stannic Chloride 4 4 1 1 Zinc Ammonium Chloride 1 1 1 1 1 Starch 1 1 1 1 1 1 1 Zinc Chloride 4 4 4 2 1 1 1 1 1 Steam 1 1 1 1 4 4 1 4 3 Zinc Hydrosulfite 1 1 1 1 1 1 1 Stearic Acid 3 1 2 1 1 3 1 1 1 Zinc Sulphate 2 1 2 1 1 1 1 1 1

KEY: 1 – Excellent 2- Good 3 – Fair 4 – Unsatisfactory Blank - Insufficient Data

NOTE: When using this table . . . Please remember that in any given case many factors such as solution concentration, temperature, degree of agitation and presence of Impurities influence the rate of corrosion. We suggest that these ratings be used

as a first approximation for your requirements rather than the final answer.

Page 13: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

GOULD <-----> ASCOCROSS REFERENCE FOR 2 - WAY SOLENOID VALVES

NORMALLY CLOSEDGOULD VALVES: Piston-Pilot Operated <> ASCO VALVES: Both Piston-Pilot & Diaphragm

AIR - WATER - GENERAL SERVICE STEAM SERVICE

BRONZE STAINLESS STEEL BRONZE STAINLESS (303)

M-3V Q-3V (to 250psi)

Q-3T (to 400psi)

K (303) KX (316) M-1-3EP (to 50psi)

M-1-3T (to 125psi)

Q-1-3T (to 200psi)

K-1 (to 200psi)

1/8" N/A N/A N/A N/A N/A N/A N/A N/A N/A

1/4" N/A N/A N/A N/A N/A N/A N/A N/A N/A

3/8" 8210G1 8210G6 8210G6 *8210G36 N/A 8220G1 8220G19 N/A N/A

1/2" 8210G2 8210G7 8210G7 *8210G37 N/A 8220G3 8220G21 N/A *8222C87

3/4" 8210G9 8210G3 8210G3 *8210G88 N/A 8220G5 8220G23 8222G5 *8222C88

1" 8210G4 *8210B27 *8210B27 *8210D89 N/A 8220G7 8220G25 822299 8222B89

1 1/4" 8210G8 8210G8 8210G8 N/A N/A 8220G9 8220G27 N/A N/A

1 1/2" 8210G22 8210G22 8210G22 N/A N/A 8220G11 8220G29 N/A N/A

2" 8210G100 8210G100 8210G100 N/A N/A 8220G13 8220G31 N/A N/A

2 1/2" -- -- 8210G101 8210G101 -- -- -- -- -- -- 8220G33 8220G33 -- --

3" -- -- 8210B51 8210B51 -- -- -- -- -- -- N/A N/A -- --

*Denotes ASCO Diaphragm Valve [GOULD Valve requires 5 psi Minimum Pressure Differential]

NORMALLY CLOSED -- DIRECT ACTING

AIR - WATER - GENERAL SERVICE STEAM SERVICE

BRONZE STAINLESS STEEL BRONZE STAINLESS STEEL

B3-21 QD F & FST K D(303)

G & GST(316)

G X BH-19 F-1(303)

G-1(316)

GX-1

1/8" -- -- -- -- 8262G1 -- -- 8262G12 N/A 8263G58 N/A N/A N/A

1/4" 8262G202 -- -- 8262G19 -- -- 8262G80 N/A 8263G300 N/A N/A N/A

3/8" 8263G2 8030G10 8263G2 8030G64 8263G330 N/A 8263G305 N/A 8263G318 N/A

1/2" -- -- 8030G16 -- -- 8030G66 -- -- N/A

3/4" -- -- 8030G3 -- -- 8030G63 -- -- N/A --- --- This pipe size is not available1" -- -- N/A -- -- -- -- -- -- N/A N/A ASCO does not offer direct comparison

NOTES:These comparisons are for Reference ONLY. Consult J.D. Gould Company for specific Solenoid Valve applications.GOULD valve designations followed by "-2" and ASCO valve designations preceeded by "EF" are NEMA 7 REV 3/02

GOULD VALVE TYPE

PIPE SIZE

GOULD VALVE TYPEP

IPE SIZE

Page 14: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

GOULD <-----> ASCOCROSS REFERENCE FOR 2 - WAY SOLENOID VALVES

NORMALLY OPEN

GOULD VALVES: Piston-Pilot Operated & Direct Acting <> ASCO VALVES: Piston-Pilot & Diaphragm

QR-3B (piston-pilot)

FR (direct acting)

GR (direct acting)

KR (piston-pilot)

GRX (direct acting)

KRX (piston-pilot)

QR-1-3T (piston-pilot)

FR-1 (direct acting)

GR-1 (direct acting)

KR-1 (piston-pilot)

1/8" N/A8262G31 8262G91

8262G94 8262G35

N/A N/A N/A N/A N/A N/A N/A

P 1/4" N/A8262G260 to G265

8262G130 to G152

N/A N/A N/A N/A N/A N/A N/A

I 3/8" *8210G33 N/A N/A N/A N/A N/A 822091 N/A N/A N/A

P 1/2"*8210G34 8210G12

-- -- -- -- *8210G30 N/A N/A 822093 -- -- -- -- N/A

E 3/4"*8210G35 8210C13

-- -- -- -- *8210G38 N/A N/A 822095 -- -- -- -- N/A

1"*8210B57 8210D14

-- -- -- -- N/A N/A N/A 822097 -- -- -- -- N/A

S 1 1/4"*8210B58 8210D18

-- -- -- -- N/A N/A N/A 822099

I 1 1/2"*8210B59 8210D32

-- -- -- -- N/A N/A N/A 8220101

Z 2" 8210103 -- -- -- -- N/A N/A N/A 8220103

E 2 1/2" 8210104 -- -- -- -- -- -- -- -- -- -- 8220105

3" N/A -- -- -- -- -- -- -- -- -- -- N/A

*Denotes ASCO Diaphragm Valve [GOULD Valve requires 5 psi Minimum Pressure Differential]

LEGEND:

-- -- Pipe Size not offered for particular GOULD VALVE type or ASCO cross-reference

N/A ASCO does not offer a direct comparison to this GOULD VALVE

NOTES:

REV 3/02

GOULD valve designations followed by "-2" and ASCO valve designations preceeded by "EF" are NEMA 7

AIR - WATER - GENERAL SERVICE STEAM SERVICE

GOULD VALVE TYPE

Stainless SteelBronzeBronze 304 Stainless Steel 316 Stainless Steel

These comparisons are for Reference use ONLY. Consult J.D. Gould Company for specific Solenoid Valve Applications.

Page 15: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

GOULD <-----> ASCO

GOULD Piston-Pilot Operated Solenoid ValvesASCO Valves: Both Piston-Pilot & Diaphragm Typ

AIR - WATER - GENERAL SERVICE STEAM SERVICE

BRONZE STAINLESS STEEL

J-3B KJ-3V J-1-3EP (0-50psi) J-1-3T (0-200psi) KJ-1-3EP (0-50psi) KJ-1-3T (0-200psi)

1/8" N/A N/A N/A N/A N/A N/A

1/4" N/A N/A N/A 8222G70 N/A N/A

3/8" 8210G93 8210G36 8222G93 8222G1 N/A N/A

1/2" 8210G94 8210G87 8222G94 8222G76 8222G60/8222G87 N/A

3/4" 8210G95 8210G88 8222G95 8222G3 8222G62 8222G88

1"8210G95 (to 150psi) 8210B27 (to 300psi)

8210G89 N/A 822299 N/A 8222G89

NOTES: These comparisons are for reference ONLY.

Consult J. D. Gould Company for specific Solenoid Valve Applications.

Gould valves listed are all NEMA 1. For NEMA 7, 5, & 4, add "-2", "-25", "-24" to the end of the Type Designation.ASCO valves with a "G" designator are NEMA 4XN/A Indicates ASCO has no direct comparison to this Type of Gould Valve

REV 3/02

BRONZE STAINLESS STEEL

PIPE SIZE

GOULD VALVE TYPE:

Page 16: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

This Page Intentionally left blank

Page 17: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PIPE SIZE ATKOMATIC CV GOULD CV PIPE SIZE ATKOMATIC CV GOULD CV1/8" N/A N/A M-3V 2.9 1/8" N/A N/A M-1-3T 2.91/4" JJ-200-Q 1.4 M-3V 2.9 1/4" HS-200-Q 1.4 M-1-3T 2.93/8" JJ-300-Q 2.7 M-3V 3.6 3/8" HS-300-Q 2.7 M-1-3T 3.61/2" JJ-400-Q 3.5 M-3V 3.6 1/2" HS-400-Q 3.5 M-1-3T 3.63/4" JJ-500-Q 7.5 M-3V 6.8 3/4" HS-500-Q 7.5 M-1-3T 6.81" JJ-600-Q 9.1 M-3V 11.5 1" HS-600-Q 9.1 M-1-3T 11.5

1-1/4" JJ-700-Q 19.5 M-3V 18 1-1/4" HS-700-Q 19.5 M-1-3T 181-1/2" JJ-800-Q 21 M-3V 26 1-1/2" HS-800-Q 21 M-1-3T 26

2" JJ-900-Q 46 M-3V 48 2" N/A N/A M-1-3T 48

NOTE Use Type M4-3V for DC voltages & 12 or 24V 60 Hz. NOTE Use Type M4-1-3Tfor DC voltages & 12 or 24V 60 Hz.Refer to page #3 of the price schedule Refer to page #3 of the price schedule

*** Required ordering information for J D Gould M-3V *** Required ordering information for J D Gould M-1-3T*Pipe Size *Pipe Size*Pressure - Must specify (5-125 psi or 10-250 psi) *Voltage*Voltage

*** NOTES:1 Optional features available for J D Gould valves refer to page #2 of list price schedule2 J D Gould coils for above valves are rated NEMA 4X (Standard)3 J D Gould above valves are UL & CSA listed for the following voltages 24,120,240,480,120/240(dual voltage) VAC,50/60hz. 26 Watts max. 4 Dual voltage coil (120/240,50/60) for ease of stock

6/3/98

CROSS REFERENCE OF ATKOMATIC TO J D GOULD

CROSS REFERENCE FOR 2 - WAY SOLENOID VALVES

BRONZE NORMALLY CLOSED

AIR - WATER - LT. OIL - GENERAL SERVICE

GOULD VALVES: Piston-Pilot Operated <> ATKOMATIC VALVES: Piston-Pilot Operated

STEAM SERVICE

SHORTY SERIES M-3V SERIES HOTSHOT SERIES M-1-3T SERIES

Page 18: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

SERIES GENERAL SERVICE / PSI STEAM / PSI SIZES TYPE GENERAL SERVICE / PSI STEAM / PSI SIZES BULLETIN #

500 5-300 5-125 1/4" - 1-1/2" M 5-250 5-125 1/8"-2" M-1-3T4000 5-500 5-200 1/4" - 1-1/2" EF 5-150 N/A 4" 40-EF5000 5-500 5-200 2" - 3" Q 5-400 5-200 1/8"-3" 200-Q6000 5-1500 5-200 1/4" - 1/2" A 5-1200 5-200 1/4"-3/8" 400-A6000 5-1000 5-200 3/4" - 1-1/2" B 5-1200 5-200 1/4"-1/2" 600-B

D 5-1200 5-200 3/4"-2" 620-D

SERIES GENERAL SERVICE / PSI STEAM / PSI SIZES TYPE GENERAL SERVICE / PSI STEAM / PSI SIZES BULLETIN #

8000 5-1500 5-300 1/4" - 2" K 5-1000 5-200 1/8"-2" 800-K

NOTE: 1. Maximum air (gas) service of 400 psi on J D Gould valves. Liquids up to maximum as shown2. Not currently available for cryogenic service 7/10/983. Not available for fuel gases (natural gas, propane, etc)

J D GOULD

Refer to specific bulletins and price list for details, Normally open styles, and Limitations

STAINLESS STEEL --- NORMALLY CLOSED

ATKOMATIC

CROSS REFERENCE OF ATKOMATIC TO J D GOULD

ATKOMATIC

GOULD VALVES: Piston-Pilot Operated <> ATKOMATIC VALVES: Piston-Pilot Operated

GENERAL REFERENCE ONLY

BRONZE --- NORMALLY CLOSED

J D GOULD

Page 19: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

Technical Bulletins J. D. Gould Company, Inc. • P. O. Box 18128 • Indianapolis, IN 46218-0128

phone: (800) 63-GOULD • fax: (317) 547-5234 website: www.gouldvalve.com • email: [email protected]

Page 20: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

This Page Intentionally left blank

Page 21: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. F

BULLETIN 120-M SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/8”-2” NPT

TYPE M & M-1Series

2-WAY - CAST BRONZE BODIES - PACKLESS

VELVETROL INTERNAL PISTON PILOT OPERATED GENERAL PURPOSE SOLENOID VALVES

NORMALLY CLOSED WHEN DE-ENERGIZED

FOR: GENERAL SERVICE-AIR-WATER-LIGHT OIL-STEAM (M-3V* LEAKPROOF) PRESSURES: 5 PSI MINIMUM TO 250 (130 FOR STEAM) PSI MAXIMUM • FULL PORT TEMPERATURE: -420°F TO 356°F. CLASS N COILS MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 2" NPT FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown on page 3 of the List Price Schedule. Valves will be furnished for 5-125 PSI and 120 VAC Unless Otherwise Specified.

- - - N O R M A L L Y C L O S E D O N L Y - - -

M-3B, M-3EP, M-3V

GENERAL PURPOSE - AIR – WATER 5-125, 10-250 PSI; 250°F. Max. Fluid, Class N 120, 240, 480, 120/240 VAC (50/60 Hz), 26 Watts Max.

M4-3B M4-3EP M4-3V

GENERAL PURPOSE - AIR - WATER - INERT GASES SELECTED LIQUIDS (Consult Factory) 5-125, 10-250 PSI; 250°F. Max. Fluid, Class N 120, 240, 480, 120/240 VAC (50/60 Hz), 26 Watts Max. 6, 12, 24, 48, 115, 230 VDC, 24 Watts Max.

M-1-3T, M-1-3EP

STEAM - HOT FLUIDS 5-130 PSI (-3EP is 5-50PSI); 356°F (-3EP is 300°F) Max. Fluid, Class N 120, 240, 480 VAC (50/60 Hz), 26 Watts Max.

TYPE M-1-3EP

LOW PRESSURE STEAM (to 50 PSI) SELECTED LIQUIDS (Consult Factory) 5-125, 10-250 PSI; 300°F. Max. Fluid, Class N 120, 240, 480, 120/240 VAC (50/60 Hz), 26 Watts Max. 6, 12, 24, 48, 115, 230 VDC, 24 Watts Max.

CONSTRUCTION: CLASS N COILS are NEMA 4X, Fungus proof, Molded of Filled Polyester with 18" Leads and ½" Conduit Connector BODIES are rated to 400 psi and Cast in Bronze. PLUNGER TUBES are Stainless Steel silver soldered to the Brass BONNET. PISTON ASSEMBLIES are Brass with Filled Teflon PISTON RINGS, Stainless Steel EXPANDERS, and Buna, EP, and Flourocarbon SEAT DISCS. PILOT VALVES & SPRINGS are Stainless Steel.

SPECIALS: Teflon Leak Proof Seat Screws, Teflon Discs (Standard on all Steam Valves), Teflon Coated Pistons & other Special Assemblies Available. Non-Standard Coils Available with Voltage, Wattage, and Lead Wire Length to your specifications.

See Price Schedule for "Terms and Conditions of Sale" (Back Cover) See Page 3 of List Price Schedule for UL and CSA Listings. * Also -3B, and -3EP

Page 22: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED I

Bulletin 120-M Series

PERFORMANCE, ORDERING AND INSTALLATION GUIDE ———————————————————————————————————————————————————————————————————————————————————————————————————————————

ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACKPRESSURE, (IF ANY). ———————————————————————————————————————————————————————————————————————————————————————————————————————————

FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. ———————————————————————————————————————————————————————————————————————————————————————————————————————————

OPERATION--PISTON PILOT OPERATED. MINIMUM PRESSURE DROP OF 5 PSI (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. ———————————————————————————————————————————————————————————————————————————————————————————————————————————

MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. ————————————————————— SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA VOLTAGE, PRESSURE, ETC.)

* Also -3B, and -3EP

Size 1/8” 1/4” 3/8” 1/2” 3/4” 1”

1 ¼” 1 ½” 2”

1/81/43/81/23/41

1 ¼1 ½2

1 ¼” M-3V

Physical Dimensions CV Weight A B C 2.9 3 lbs 5.13 4.25 2.75 2.9 3 lbs 5.13 4.25 2.75 3.6 3 lbs 5.13 4.25 2.75 3.6 3 lbs 5.13 4.25 2.75 6.8 4 lbs 5.50 4.50 3.25 11.5 5 lbs 5.75 4.56 3.81 18 7 lbs 6.50 5.06 4.25 26 9 lbs 7.06 5.38 4.88

48 14 lbs 8.00 5.88 5.88

1 2 2 3 4 5 5 6 6 7 7 8 9 10 10 11 12 13 14 15

Size

Bonn

et

Asse

mbl

y M-

3V B

onn

O-

Ring

M-3V

* Bon

n

O-Ri

ng

Bonn

et

Ring

Pi

ston

Sp

ring

M-3V

* Se

atSc

rew

M-1-

3T

Seat

Scre

w

M-3V

* Pi

st A

ssm

.

M-1-

3T P

ist.

Assm

M-3V

* Pi

lot V

alve

M-1-

3T P

ilot

Valve

Pi

ston

Onl

y Pi

ston

Rin

g

Expa

nder

M-

3V* S

eat

Disc

M-1-

3T S

eat

Disc

Guid

e Nut

Body

Coil N

ut

Nam

e Plat

e

Coil

” 403-1 2-121 2-121 N/A 37-14 415-31 415-31T 407-3 407-T-3T 486NP 486 402 57 36-012 36-012T 406 400-8 6-15 44-1 ” 403-1 2-121 2-121 N/A 37-14 415-31 415-31T 407-3 407-T-3T 486NP 486 402 57 36-012 36-012T 406 400-8 6-15 44-1 ” 403-1 2-121 2-121 N/A 37-14 415-31 415-31T 407-3 407-T-3T 486NP 486 402 57 36-012 36-012T 406 400-8 6-15 44-1 ” 403-1 2-121 2-121 N/A 37-14 415-31 415-31T 407-3 407-T-3T 486NP 486 402 57 36-012 36-012T 406 400-8 6-15 44-1 ” 413-1 2-125 2-125 N/A 37-3 415-3 415-3T 417-3 417-T-3T 486NP 486 412 159 36-034 36-034T 416 410 6-15 44-1

” 423-1 N/A N/A 428 37-3 415-31 415-31T 427-3 427-T-3T 486NP 486 422 58 36-100 36-100T 429 420 6-15 44-1 ” 433-1 N/A N/A 438 37-2 415-31 415-31T 437-3 437-T-3T 486NP 486 432 434 36-114 36-114T 439 430 6-15 44-1 ” 443-1 N/A N/A 448 37-2 415-31 415-31T 447-3 447-T-3T 486NP 486 442 93 36-112 36-112T 449 440 6-15 44-1

” 453-1 2-40 2-40 458 37-2 415-31 415-31T 457-3 457-T-3T 486NP 486 452 176 36-200 36-200T 459 450 6-15 44-1

Consult Factory

OR

List Price Schedule

N USA

Rev. F
Page 23: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. C

BULLETIN 200-Q SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Les Vannes Famco Quebec Distributor Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/8”-3” NPT

TYPE Q & QRSeries

2-WAY – CAST BRONZE BODIES - PACKLESS

VELVETROL INTERNAL PISTON PILOT OPERATED GENERAL PURPOSE SOLENOID VALVES - FULL PORT

NORMALLY CLOSED OR NORMALLY OPEN

FOR: GENERAL SERVICE-AIR-INERT GASES-WATER-OIL-STEAM PRESSURES: 5 PSI DIFFERENTIAL MINIMUM TO 400 PSI MAXIMUM TEMPERATURE: -420°F TO 450°F. CLASS F OR N COILS MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 3" NPT FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in Price Schedule. Valves will be furnished for 5-150 PSI Air-Water and 120 VAC Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

Q-3B, Q-3EP, Q-3V

Q-3T

GENERAL PURPOSE – AIR – WATER 5-150, 10-400 PSI (Normally Open to 300 PSI) 220°F. Max. Fluid Temp. Class F Coils: 120, 240, 480 VAC 60 Hz, 14Watts Max.

QR-3B, QR-3EP QR-3V, QR-3T

Q4-3B, Q4-3EP Q4-3V, Q4-3T

GENERAL PURPOSE: AIR – WATER - INERT GASES – WATER – OIL 5-150, 10-400 PSI (Normally Open to 300 PSI) 300°F. Max. Fluid Temp. Class F. Non-Standard Coils Available With Voltage, Wattage, and Lead Wire Length To Your Specs.

QR-3B, QR-3EP QR-3V, QR-3T

Q-1-3T, Q-1-3EP

STEAM 5-150 PSI; 365°F Max. Fluid Temp., (-3EP: 5-50, 300°F); Class N 120, 240, 480 VAC 60 Hz, 20 Watts Max.

QR-1-3T QR-1-3EP

Q4-1-3T, Q4-1-3EP STEAM (to 200 PSI) – HOT FLUIDS (to 450°F) SIMILAR TO Q4 Series EXCEPT High Temp. QR-1-3T, QR-1-3EP

ADD -1 HIGH TEMP. (CLASS N) COILS - FLUID TEMP. TO 450°F. STEAM to 200 PSI. ADD -1

ADD -2 EXPLOSION PROOF COIL HOUSING – UL CLASS I GROUP D, CLASS II GROUP E, F, G. NEMA 7 ADD -2

ADD -3B, -3EP -3V, -3T

LEAKPROOF PILOT SEAT: -3 O-RING (BUNA, ETHYLENE- PROPYLENE, FLOUROCARBON (VITON), & PTFE); -3T PTFE, -3V FLOUROCARBON (VITON)

ADD -3B, -3EP -3V, -3T

ADD -24 WATER TIGHT COIL HOUSING - NEMA 4 ADD -24 ADD -25 DUST TIGHT COIL HOUSING - NEMA 5 ADD -25

ADD -57 MANUAL RESET – SAFETY SHUT-OFF, NO VOLTAGE RELEASE. SEE BULLETIN 210-Q57 ADD -57

ADD -81, -84 -81 SLOW CLOSE (REDUCES WATER HAMMER) -84 QUICK CLOSE (BOTH FACTORY SETUPS) ADD -81, 84

ADD -9 SPECIAL CONSTRUCTION FOR CRYOGENIC APPLICATIONS. FLUID TEMP. TO –420°F. SEE BULLETIN -9 CRYOGENICS ADD -9

ADD -230 SPECIAL CONSTRUCTION FOR GASOLINE AND DIESEL FUEL. SEE BULLETIN 230-Q ADD -230

ADD -FL PIPE CONNECTION:-FL FLANGE ADD -FL

Page 24: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. C

Bulletin 200-Q Series

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are Sand Cast in Bronze rated 400 psi WOG. PISTON SPRINGS are 316 or 302 SS. BONNET ASSEMBLIES are 304 SS TUBES silver soldered to Brass BONNET and TUBE PLUG. PISTON ASSEMBLIES are Brass with Filled Teflon PISTON RINGS, Stainless Steel EXPANDERS, and Buna, EP, Fluorocarbon, or Virgin Teflon SEAT DISCS. PILOT ASSEMBLIES are 416 SS ARMATURE with a 316 SS PILOT POINT and 316 SS PINS.

SPECIALS: Teflon Leak Proof Seat Screws, Teflon Discs (Standard on all Steam Valves), Teflon Coated Pistons & other Special Assemblies Available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory.

See Price Schedule for "Terms and Conditions of Sale." (Back Cover) ———————————————————————————————————————————————————————————————————————————————————————————

PERFORMANCE, ORDERING AND

INSTALLATION GUIDE ———————————————————————— ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). ———————————————————————— FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. ————————————————————————OPERATION--PISTON PILOT OPERATED. MINIMUM PRESSURE DROP OF 5 PSI (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. ———————————————————————— MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NO LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. PTFE TAPE STRONGLY RECOMMENDED FOR ALL JOINTS. ———————————————————————— OPERATING PRESSURE: THE SOLENOID VALVE SHOULD BE ORDERED WITH THE MAXIMUM RATED PRESSURE CLOSEST TO THE ACTUAL PRESSURE THE VALVE WILL OPERATE IN. FOR EXAMPLE: IF YOUR APPLICATION IS FOR 40 PSI, ORDER A VALVE RATED 5-125 PSI NOT 10-250 PSI. ———————————————————————— SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.) ¾” Type Q-3V

Page 25: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED

Bulletin 200-Q Series

1 1a 2 3 4 5 6 7 7a 8 9 10 11 12 13 14

Val

ve S

ize

N.C

. Bon

net

Ass

embl

y

N.O

. Bon

net

Ass

embl

y

Bon

net S

eal

Bon

net R

ing

Pist

on S

prin

g

Seat

Scre

w

Pis

ton

Ass

embl

y N

.C. P

ilot

Ass

embl

y

N.O

. Pilo

t A

ssem

bly

Pis

ton

Onl

y

Pis

ton

Rin

g &

Exp

ande

r

Seat

Dis

c

Gui

deN

ut

Bod

y

Coi

l Scr

ew

Nam

epla

te

Q-3V* QR-3V* BOTH BOTH BOTH BOTH BOTH Q-3V* QR-3V* BOTH BOTH BOTH BOTH BOTH BOTH BOTH 1/8 4032 4032R 2121x N/A 37-14 415-3xx 4073x 25-1 32R1 402 57 3612x 406B 400-8 9 44-1-1 1/4 4032 4032R 2121x N/A 37-14 415-3xx 4073x 25-1 32R1 402 57 3612x 406B 400-4 9 44-1-1 3/8 4032 4032R 2121x N/A 37-14 415-3xx 4073x 25-1 32R1 402 57 3612x 406B 400-1 9 44-1-1 1/2 4032 4032R 2121x N/A 37-14 415-3xx 4073x 25-1 32R1 402 57 3612x 406B 400-2 9 44-1-1 3/4 4132 4132R 2125x N/A 37-3 415-3x 4173x 25-1 32R1 412 159 3634x 416 410 9 44-1-1 1 4232 4232R N/A 428 37-3 415-3xx 4273x 25-1 32R1 422 58 361x 429 420 9 44-1-1

1-1/4 4332 4332R N/A 438 37-2 415-3xx 4373x 25-1 32R1 432 434 36114x 439 430 9 44-1-1 1-1/2 4432 4432R N/A 448 37-2 415-3xx 4473x 25-1 32R1 442 93 36112x 449 440 9 44-1-1

2 4532 4532R 240x 458 37-2 415-3xx 4573x 25-1 32R1 452 176 362x 459 450 9 44-1-1 2-1/2 4632 4632R 2-42x 468 37-2 415-3xx 4673x 22-1 32R6 462 102 36212x 469 460 9 44-1-1

3 4732 4732R 2-46x 478 37-2 415-3xx 4773x 22-1 32R6 472 474 363x 479 470 9 44-1-1

15 15a 16 16a 17 18

Val

ve S

ize

N.C

. Nip

N.O

. Nip

N.C

. Coi

l C

over

N.O

. Coi

l C

over

Coi

l

Coi

l Can

Q-3V* QR-3V* Q-3V* QR-3V* BOTH BOTH 1/8 1152 1153 89 89NO 87 1/4 1152 1153 89 89NO 87 3/8 1152 1153 89 89NO 87 1/2 1152 1153 89 89NO 87 3/4 1152 1153 89 89NO 87 1 1152 1153 89 89NO 87

1-1/4 1152 1153 89 89NO 87 1-1/2 1152 1153 89 89NO 87

2 1152 1153 89 89NO 87 2-1/2 1152 1153 89 89NO 87

3 1152 1153 89 89NO

Consult Factory

or

List Price Schedule

87

Valve Dimensions

N. C. N. O.

Val

ve S

ize

CV

Fac

tor

A B C wt lbs

A B C wt lbs

1/8 2.9 6.31 5.5 2.75 3 7.31 6.5 2.75 4 1/4 2.9 6.31 5.5 2.75 3 7.31 6.5 2.75 4 3/8 3.6 6.31 5.5 2.75 3 7.31 6.5 2.75 4 1/2 3.6 6.31 5.5 2.75 3 7.31 6.5 2.75 4 3/4 6.8 6.69 5.7 3.25 4 7.69 6.7 3.25 4 1 11.5 7.0 5.83 3.81 5 8.0 6.83 3.81 5

1-1/4 18.0 7.7 6.3 4.25 6 8.7 7.3 4.25 7 1-1/2 26 8.27 6.64 4.88 8 9.27 7.64 4.88 9

2 48 8.88 6.94 5.88 13 9.88 7.94 5.88 14 2-1/2 75 9.63 7.3 7.00 18 10.63 8.3 7.00 18

3 100 10.6 7.8 8.25 27 11.6 8.8 8.25 27 * Also for -3B, -3EP, & -3T Valves

1” Type QR-3V

Rev. C

Page 26: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED

Bulletin 200-Q Series

1b 1c 7b 7c 20 21 22 23 24 V

alve

Si

ze

N.C

. XP

B

onne

t A

ssem

bly

N.O

. XP

B

onne

t A

ssem

bly

N.C

. XP

P

ilot

Ass

embl

y

N.O

. XP

P

ilot

Ass

embl

y

Coi

l E

ndpl

ates

Coi

l Sp

ring

N.C

. XP

C

over

N.O

. XP

C

over

XP

Bol

ts

XP

Was

hers

XP

Bas

e

Q-3V-2* QR-3V-2* Q-3V-2* QR-3V-2* Q-3V-2* QR-3V-2*

Q-3V-2* QR-3V-2* Q-3V-2* QR-3V-2* Q-3V-2*

QR-3V-2* Q-3V-2*

QR-3V-2* Q-3V-2*

QR-3V-2* 1/8 4032XP 4032RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A 1/4 4032XP 4032RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A 3/8 4032XP 4032RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A 1/2 4032XP 4032RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A 3/4 4132XP 4132RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A 1 4232XP 4232RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A

1-1/4 4332XP 4332RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A 1-1/2 4432XP 4432RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A

2 4532XP 4532RXP 22-1 P32R6 113 37-2 42NC 42NO 9-4 46-3 41A 2-1/2 4632XP 4632RXP 24-1 P32R7 113 37-2 42NC 42NO 9-4 46-3 41A

3 4732XP 4732RXP 24-1 P32R7 113 37-2 42NC 42NO 9-4 46-3 41A

size A B C wt size A B C wt 1/8 7 6.19 2.75 7 1/8 8.13 7.31 2.75 8 1/4 7 6.19 2.75 7 1/4 8.13 7.31 2.75 8 3/8 7 6.19 2.75 7 3/8 8.13 7.31 2.75 8 1/2 7 6.19 2.75 7 1/2 8.13 7.31 2.75 8 3/4 7.38 6.38 3.25 8 3/4 8.50 7.50 3.25 8 1 7.63 6.44 3.81 9 1 8.75 7.56 3.81 9

1-1/4 8.38 6.88 4.25 10 1-1/4 9.50 8.00 4.25 11 1-1/2 8.88 7.25 4.88 12 1-1/2 10.00 8.38 4.88 13

2 9.81 7.69 5.88 17 2 10.94 8.81 5.88 18 2-1/2 10.13 8.25 7 22

The Explosionproof housing is constructed of two (2) machined, sand-cast gray iron parts bolted together, threaded onto the bonnet assembly and rigidly cemented in place. Once assembled the housing will not rotate. NEMA 4, NEMA 5, or NEMA 7 ratings are available with this housing.

2-1/2 11.25 9.38 7 22 3 11.19 8.38 8.25 31

Phy

sica

l Dim

ensi

ons

of

Nor

mal

ly C

lose

d V

alve

s

* Also for -3B, -3EP, & -3T Valves 3 12.31 9.50 8.25 31

Phy

sica

l Dim

ensi

ons

of

Nor

mal

ly O

pen

Val

ves

1 2 3 2

” Q-3V- /4” QR-3V-

Rev. C

Page 27: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 230-Q SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/8”-3” NPT

TYPES Q-230 & QR-230

2-WAY – CAST BRONZE BODIES - PACKLESS

VELVETROL INTERNAL PISTON PILOT OPERATED SAFETY SOLENOID VALVES FOR HAZARDOUS LOCATIONS

NORMALLY CLOSED OR NORMALLY OPEN - FULL PORT

FOR: CLASS1, GROUP D FOR GASOLINE, DIESEL FUEL, #1 AND #2 FUEL OIL PRESSURES: 5 PSI DIFFERENTIAL MINIMUM TO 150 PSI MAXIMUM TEMPERATURE: 77°F. MAX. AMBIENT TEMP. CLASS F, 220°F MAX FLUID MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 3" NPT FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for 5-100 PSI and 120 VAC Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE Q-230

5-100 PSI, 77°F. Max. Fluid, 77°F. Max. Ambient, Class F 120, 240, 480 VAC 60 Hz, 14 Watts Max. N/A

TYPE Q4-230 5-150 PSI, 300°F. Max. Fluid, Class F 12, 24, 120, 240, 480 VAC 60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE QR-230

ADD -81, -84 -81 SLOW CLOSE (REDUCES WATER HAMMER) -84 QUICK CLOSE (BOTH FACTORY SETUPS) ADD -81, -84

ADD -FL PIPE CONNECTION: -FL FLANGE ADD -FL CONSTRUCTION:

CLASS F COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads, inside a Cast Iron NEMA 7 COIL HOUSING with a ½” NPT Conduit Connector. BODIES are Globe Style with Union Bonnets, rated to 400 psi, Cast in Bronze. PISTON SPRINGS are Stainless Steel. BONNET ASSEMBLIES are 304 SS TUBES, Brass BONNETS, and Brass TUBE PLUGS silver soldered together. PISTON ASSEMBLIES are Brass with Filled PTFE PISTON RINGS and SS EXPANDERS. SEAT DISCS and PILOT DISC are Flourocarbon. PILOT ASSEMBLIES are 416 SS ARMATURE with a 316 SS PILOT POINT and 316 SS PINS.

See List Price Schedule for "Terms and Conditions of Sale" (Back Cover) ——————————————————————————————————————————————————

PERFORMANCE, ORDERING AND INSTALLATION GUIDE

ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). ————————————————————————————————————————————————————————————————————————————————————

FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. ————————————————————————————————————————————————————————————————————————————————————

OPERATION--PISTON PILOT OPERATED. MINIMUM PRESSURE DROP OF 5 PSI (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. ————————————————————————————————————————————————————————————————————————————————————

MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

(to 2”)

Page 28: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

Bulletin 230-Q Series

1a 1b 2 3 4 5 6a 6b 7 8 9 10 11 12 13 14 15 16 17 V

alve

Siz

e

N. C

. Bon

n.

Ass

embl

y

N. O

. Bon

n.

Ass

embl

y

Bon

n. R

ing

Pist

on

Spri

ng

Seat

Sc

rew

Pist

on

Ass

embl

y N

.C. P

ilot

Ass

embl

y N

. O. P

ilot

Ass

embl

y Pi

ston

O

nly

Pisto

n R

ing

& E

xpan

der

Seat

Dis

c

Gui

deN

ut

Bod

y

Coi

l Scr

ew

Nam

epla

te

Coi

l

O-R

ing

Coi

l E

ndpl

ates

C

oil

Spri

ng

Q230 QR230 ALL ALL ALL ALL Q230 QR230 ALL ALL ALL ALL ALL ALL ALL ALL ALL Q230 QR230 1/8 4032XP 4032RXP N/A 37-14 415-21V 4073VV 22-1 32R6 402 57 3612V 406B 400-8 9 4434 2121V 113 37-2 1/4 4032XP 4032RXP N/A 37-14 415-21V 4073VV 22-1 32R6 402 57 3612V 406B 400-4 9 4434 2121V 113 37-2 3/8 4032XP 4032RXP N/A 37-14 415-21V 4073VV 22-1 32R6 402 57 3612V 406B 400-1 9 4434 2121V 113 37-2 1/2 4032XP 4032RXP N/A 37-14 415-21V 4073VV 22-1 32R6 402 57 3612V 406B 400-2 9 4434 2121V 113 37-2 3/4 4132XP 4132RXP N/A 37-3 415-3-V 4173VV 22-1 32R6 412 159 3634V 416B 410 9 4434 2125V 113 37-2 1 4232XP 4232RXP 428 37-3 415-21V 4273VV 22-1 32R6 422 58 361V 429 420 9 4434 N/A 113 37-2

1-1/4 4332XP 4332RXP 438 37-2 415-21V 4373VV 22-1 32R6 432 434 36114V 439 430 9 4434 N/A 113 37-2 1-1/2 4432XP 4432RXP 448 37-2 415-21V 4473VV 22-1 32R6 442 93 36112V 449 440 9 4434 N/A 113 37-2

2 4532XP 4532RXP 458 37-2 415-21V 4573VV 22-1 32R6 452 176 362V 459 450 9 4434 2-40V 113 37-2 2-1/2 4632XP 4632RXP 468 37-2 415-31V 4673VV 24-1 32R7 462 102 36212V 469 460 9 4434 2-42V 113 37-2

3 4732XP 4732RXP 478 37-2 415-31V 4773VV 24-1 32R7 472 474 363T 479 470 9 4434

Consult Factory or the List Price

Schedule

2-46V 113 37-2

18a 18b 19 20 Normally Closed Normally Open

N.C

. XP

Cov

er

N.O

. XP

Cov

er

Bol

ts

Was

hers

X

P B

ase

Cv A B C Ship

W

eigh

t A B C Sh

ip

Wei

ght

Q230 QR230 ALL ALL ALL ALL

Val

ve S

ize

(in) (in) (in) (lbs)

Val

ve S

ize

(in) (in) (in) (lbs) 42NC 42NO 9-4 46-3 41A 2.9 1/8 7 6.19 2.75 1/8 8.13 7.31 2.75 42NC 42NO 9-4 46-3 41A 2.9 1/4 7 6.19 2.75 1/4 8.13 7.31 2.75 42NC 42NO 9-4 46-3 41A 3.6 3/8 7 6.19 2.75 3/8 8.13 7.31 2.75 42NC 42NO 9-4 46-3 41A 3.6 1/2 7 6.19 2.75 1/2 8.13 7.31 2.75 42NC 42NO 9-4 46-3 41A 6.8 3/4 7.38 6.38 3.25 3/4 8.50 7.50 3.25 42NC 42NO 9-4 46-3 41A 11.5 1 7.63 6.44 3.81 1 8.75 7.56 3.81 42NC 42NO 9-4 46-3 41A 18 1-1/4 8.38 6.88 4.25 1-1/4 9.50 8.00 4.25 42NC 42NO 9-4 46-3 41A 26 1-1/2 8.88 7.25 4.88 1-1/2 10.00 8.38 4.88 42NC 42NO 9-4 46-3 41A 48 2 9.81 7.69 5.88 2 10.94 8.81 5.88 42NC 42NO 9-4 46-3 41A 75 2-1/2 10.13 8.25 7 2-1/2 11.25 9.38 7 42NC 42NO 9-4 46-3 41A 100 3 11.19 8.38 8.25

Ph

ysi

cal

Dim

ensi

on

s

The Explosionproof housing is constructed of two (2) machined, sand-cast gray iron parts bolted together, threaded onto the bonnet assembly and rigidly cemented in place. Once assembled the housing will not rotate. NEMA 4, NEMA 5, or NEMA 7 ratings are available with this housing.

3 12.31 9.50 8.25

Ph

ysi

cal

Dim

ensi

on

s

Page 29: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. B

BULLETIN 400-A SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/4”-3/8” NPT

TYPE A Series

2-WAY – CAST BRONZE BODIES - PACKLESS

VELVETROL INTERNAL PISTON PILOT OPERATED SOLENOID VALVES NORMALLY CLOSED OR NORMALLY OPEN - FULL PORT

FOR: GENERAL SERVICE-AIR-INERT GASES-WATER-OIL-STEAM PRESSURES: 5 PSI DIFFERENTIAL MINIMUM TO 1200 PSI MAXIMUM TEMPERATURE: -420°F. MIN TO 450°F MAX. FLUID MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/4" - 3/8" NPT FULL PORT

SERVICE RATINGS

Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for 5-150 PSI and 120 VAC Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE A GENERAL SERVICE AIR-WATER-OIL-INERT GASES 5-150 PSI, 300°F. Max. Fluid, Class F Coil TYPE AR

TYPE AST GENERAL SERVICE AIR-WATER-OIL-INERT GASES 10-400 PSI, (10-300 Normally Open) 300°F. Max. Fluid, Class F Coil TYPE AR

TYPE AHP LIQUID SERVICE ONLY 20-1200 PSI, 300°F. Max. Fluid, Class F Coil n/a

ADD -1 HIGH TEMP. (CLASS N) COILS - FLUID TEMP. TO 450°F. STEAM to 200 PSI. ADD -1

ADD -2 EXPLOSION PROOF COIL HOUSING – NEMA 7 ADD -2

ADD -3B, -3EP -3V, -3T

LEAKPROOF PILOT SEAT: -3B O-RING (BUNA, ETHYLENE- PROPYLENE, FLOUROCARBON (VITON), & PTFE); -3T PTFE, -3V FLOUROCARBON (VITON)

ADD -3B, -3EP -3V, -3T

ADD -9 CRYOGENIC APPLICATIONS – Fluid temps to -420°F ADD -9 ADD -24 WATER TIGHT COIL HOUSING - NEMA 4 ADD -24 ADD -25 DUST TIGHT COIL HOUSING - NEMA 5 ADD -25 ADD -57 MANUAL RESET - SAFETY SHUT-OFF, NO VOLTAGE

RELEASE. ADD -57

ADD -81, -84 -81 SLOW CLOSE (REDUCES WATER HAMMER) -84 QUICK CLOSE (BOTH FACTORY SETUPS) ADD -81, -84

ADD -FL PIPE CONNECTION: -FL FLANGE ADD -FL

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are Sand Cast in Bronze rated 1200 psi. PISTON SPRINGS are 316 or 302 SS. BONNET ASSEMBLIES are 304 SS TUBES silver soldered to Brass BONNET and TUBE PLUG. PISTON ASSEMBLIES are Brass with Filled Teflon PISTON RINGS, Stainless Steel EXPANDERS, and Buna, EP, Fluorocarbon Or Virgin Teflon SEAT DISCS. PILOT ASSEMBLIES are 416 SS ARMATURE with a 316 SS PILOT POINT and 316 SS PINS.

SPECIALS: Teflon Coated Pistons & other Special Assemblies Available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory.

TERMS AND CONDITIONS OF SALE: See Back Cover of the List Price Schedule.

Page 30: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINT

# 1

2 3 4 5 6

7 8 9 10 11 12 13

14 15

16

D

Bulletin 400-A Series

PERFORMANCE, ORDERING AND INSTALLATION GUIDE ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). —————————————————————————————————————————————————————————————————————————————————————-

FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. —————————————————————————————————————————————————————————————————————————————————————

OPERATION--PISTON PILOT OPERATED. MINIMUM PRESSURE DROP OF 5 PSI (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. —————————————————————————————————————————————————————————————————————————————————————

MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. —————————————————————————————————————————————————————————————————————————————————————

SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

3/8” Type A-3V

Part Description Valve Type 1/4” 3/8” N. C. Bonn. Assm, A 67A 67A N. O. Bonn. Assm. AR 67R 67R N. C. XP Bonn. Assm, A-2 67AXP 67AXP N. O. XP Bonn. Assm. AR-2 67RXP 67RXP Piston Spring ALL 37-14 37-14 SeatScrew ALL 31-x 31-x Piston Assembly ALL 29-2x 29-2x Piston Only ALL 29 29 N.C. Pilot Assm. A 21-1 21-1 N. O. Pilot Assm. AR 32R-2 32R-2 N.C. XP Pilot Assm. A-2 25-1 25-1 N. O. XP Pilot Assm. AR-2 32R-1 32R-1 Piston Ring & Expander ALL 57 57 Seat Disc ALL 36-12x 36-12x DiscScrew ALL 33-2 33-2 Body ALL 64-1 64-2 Coil Screw ALL 9 9 Nameplate ALL 44-1-1 44-1-1 N.C. Top Nip A 115-2 115-2 N.O. Top Nip AR 115-3 115-3 XP End Plate A-2 & AR-2 113 113 Coil Consult Factory or Price Schedule N.C. Coil Cover A 89 89 N.O. Coil Cover AR 89NO 89NO N.C. XP Coil Cover A-2 42NC 42NC N.O. XP Coil Cover AR-2 42NO 42NO Bolts A-2 & AR-2 9-4 9-4 Washers A-2 & AR-2 46-3 46-3 Coil Housing A & AR 87 87 XP Coil Housing A-2 & AR-2 41A 41A Cv ALL 1.2 2.0

Valve Type (Independent of Pipe Size)

imension A AR A-2 AR-2 A 6.4 in 7.2 6.8 6.9 B 5.8 in 6.6 6.2 7.3 C 2.5 in 2.5 2.5 2.5

Weight 3 lbs 3 lbs 7 lbs 7 lbs

ED IN USA Rev. B

Page 31: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. B

BULLETIN 600-B SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

¼”, ⅜”, & ½” NPT

TYPES B Series

2-WAY • CAST BRONZE BODIES • PACKLESS • VELVETROL INTERNAL PISTON

PILOT OPERATED SOLENOID VALVES • NORMALLY CLOSED OR NORMALLY OPEN FULL PORT • MANUAL OPEN • ADJUSTABLE CLOSING SPEED

FOR: GENERAL SERVICE-AIR-INERT GASES-WATER-OIL-STEAM PRESSURES: 5 PSI DIFFERENTIAL MINIMUM TO 1200 PSI MAXIMUM TEMPERATURE: -40°F. MIN TO 450°F MAX. FLUID MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES ¼”, ⅜”, & ½” NPT FULL PORT

SERVICE RATINGS

Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for 5-150 PSI and 120 VAC Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE B GENERAL SERVICE AIR-WATER-OIL-INERT GASES 5-150 PSI, 300°F. Max. Fluid, Class F Coil TYPE BR

TYPE BS GENERAL SERVICE AIR-WATER-OIL-INERT GASES 10-400 PSI, (10-300 Normally Open) 300°F. Max. Fluid, Class F Coil TYPE BR

TYPE BST LIQUID SERVICE ONLY 10-700 PSI, 300°F. Max. Fluid, Class F Coil n/a

TYPE BHP LIQUID SERVICE ONLY 20-1200 PSI, 300°F. Max. Fluid, Class F Coil n/a

ADD -1 HIGH TEMP. (CLASS N) COILS - FLUID TEMP. TO 450°F. STEAM to 200 PSI. ADD –1

ADD -2 EXPLOSION PROOF COIL HOUSING – CLASS I GROUP D, CLASS II GROUP E, F, G. NEMA 7 ADD –2

ADD -3B, -3EP -3V, -3T

LEAKPROOF PILOT SEAT: -3 O-RING (BUNA, ETHYLENE- PROPYLENE, FLOUROCARBON (VITON), & PTFE); -3T PTFE, -3V FLOUROCARBON (VITON)

ADD -3B, -3EP -3V, -3T

ADD -24 WATER TIGHT COIL HOUSING - NEMA 4 ADD -24 ADD -25 DUST TIGHT COIL HOUSING - NEMA 5 ADD -25 ADD -57 MANUAL RESET/SAFETY SHUT-OFF, NO VOLTAGE RELEASE. ADD -57 ADD -81, -84 -81 SLOW CLOSE & -84 QUICK CLOSE (FACTORY SETUPS) ADD -81, -84 ADD -FL PIPE CONNECTION: -FL FLANGE ADD -FL

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are Sand Cast in Bronze rated 1200 psi, with 303 SS ADJUSTMENT STEMS. BONNET ASSEMBLIES are 304 SS TUBES silver soldered to Brass BONNET and TUBE PLUG. PISTON ASSEMBLIES are Brass with Filled Teflon PISTON RINGS, Stainless Steel EXPANDERS, and Buna, EP, Fluorocarbon Or Virgin Teflon SEAT DISCS. PISTON SPRINGS are 316 or 302 SS. PILOT ASSEMBLIES are 416 SS ARMATURE with a 316 SS PILOT POINT and 316 SS PINS.

SPECIALS: Teflon Coated Pistons & other Special Assemblies Available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory.

TERMS AND CONDITIONS OF SALE: See Back Cover of the List Price Schedule.

Page 32: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINT

# 1 2 3 4 5 6 7 8 9

101112

13141516171819

2021

23

Bulletin 600-B Series

PERFORMANCE, ORDERING AND INSTALLATION GUIDE

ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). —————————————————————————————————————————————————————————————————————————————————————-

FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR CV‘S BELOW AND IN BULLETIN CP-1. —————————————————————————————————————————————————————————————————————————————————————

OPERATION--PISTON PILOT OPERATED. MINIMUM PRESSURE DROP OF 5 PSI (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. TURN STEM MARKED “ADJ” CLOCKWISE TO INCREASE CLOSING TIME. TURN STEM MARKED “MAN OPN” COUNTER CLOCKWISE TO OPEN THE VALVE MANUALLY. TURN CLOCKWISE UNTIL SEATED TO CLOSE VALVE FOR NORMAL OPERATION. —————————————————————————————————————————————————————————————————————————————————————

MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. —————————————————————————————————————————————————————————————————————————————————————

FLOW CONTROL--(Types BL & BSTL)--TURN FLOW CONTROL STEM (In Bottom Plug) CLOCKWISE to DECREASE FLOW, COUNTER CLOCKWISE TO INCREASE FLOW. —————————————————————————————————————————————————————————————————————————————————————

SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

Type B-3T

PDimensi

A B

End to End L

Part Description Valve Type 1/4” • 3/8” • 1/2” N. C. Bonn. Assm, B P30A N. O. Bonn. Assm. BR P30R N. O. Bonn. Assm. B-2 P30XP N. O. Bonn. Assm. BR-2 P30XPR Piston Spring ALL 37-14 HP Piston Spring ALL HP’s 37-4 SeatScrew ALL 31-4x Piston Assembly ALL P29-1x Piston Only ALL 29 Seat Ring ALL 34 Bottom Plug ALL 35 Flow Ctrl Btm Plug ALL BL’s 35-1 Packing Retainer ALL 69 Packing ALL 16

Packing Gland ALL 15 Adjustment Stem ALL 2-1 N.C. Pilot Assm B P21-1 N.O. Pilot Assm BR P32R-2 N.C. XP Pilot Assm B-2 P25-1 N.O. XP Pilot Assm BR-2 P32R-1

Piston Ring & Exp. ALL P57 Seat Disc ALL 36-12x Disc Screw ALL 33 Body ALL 28 Coil Screw ALL 9 Nameplate ALL 44-x N.C. Top Nip B 115-2 N.O. Top Nip BR 115-3 XP End Plate B-2 & BR-2 113

Coil ALL Consult Factory or Price Schedule N.C. Coil Cover B 89 N.O. Coil Cover BR 89NO N.C. XP Coil Cover B-2 42NC N.O. XP Coil Cover BR-2 42NO XP Bolts B-2 & BR-2 9-4 XP Washers B-2 & BR-2 46-3

Coil Housing B & BR 87 XP Coil Housing B-2 & BR-2 41

CV Factor 1/4” 1.9 3/8” 2.8 1/2” 3.3 ALL BL’s Adjustable

ED IN USA

Shipping W

hysical Dimensions of Type B Valves on B BR B-2 BR-2

7.3 8.3 7.9 9.0 5.7 6.7 6.3 7.4

ength 2.8 2.8 2.8 2.8

Rev. B

eight 5 lbs 5 lbs 9 lbs 9 lbs

Page 33: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 620-D SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

3/4”-2” NPT

TYPE D Series

2-WAY • CAST BRONZE BODIES • PACKLESS • VELVETROL INTERNAL PISTON PILOT OPERATED SOLENOID VALVES • NORMALLY CLOSED OR NORMALLY

OPEN • FULL PORT • MANUAL OPEN • ADJUSTABLE CLOSING SPEED

FOR: GENERAL SERVICE-AIR-INERT GASES-WATER-OIL-STEAM PRESSURES: 5 PSI DIFFERENTIAL MINIMUM TO 1200 PSI MAXIMUM TEMPERATURE: -40°F. MIN TO 450°F MAX. FLUID MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 3/4" – 2" NPT FULL PORT

SERVICE RATINGS

Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for 5-150 PSI and 120 VAC Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE D GENERAL SERVICE AIR-WATER-OIL-INERT GASES 5-150 PSI, 300°F. Max. Fluid, Class F Coil TYPE DR

TYPE DS GENERAL SERVICE AIR-WATER-OIL-INERT GASES 10-400 PSI, (10-300 Normally Open) 300°F. Max. Fluid, Class F Coil TYPE DR

TYPE DST LIQUID SERVICE ONLY 20-700 PSI, 300°F. Max. Fluid, Class F Coil n/a

TYPE DHP LIQUID SERVICE ONLY 20-1200 PSI, 300°F. Max. Fluid, Class F Coil n/a

ADD L PROVIDES ADJUSTMENT TO CONTROL FLOWRATE ADD L ADD -1 HIGH TEMP. (CLASS N) COILS - FLUID TEMP. TO 450°F.

STEAM to 200 PSI. ADD -1

ADD -2 EXPLOSION PROOF COIL HOUSING –NEMA 7, WATERTIGHT and Dust-tight ADD -2

ADD -3B, -3EP -3V, -3T

LEAKPROOF PILOT SEAT: -3 O-RING (BUNA, ETHYLENE- PROPYLENE, FLOUROCARBON (VITON), & PTFE); -3T PTFE, -3V FLOUROCARBON (VITON)

ADD -3B, -3EP -3V, -3T

ADD -24 WATER TIGHT COIL HOUSING - NEMA 4 ADD -24 ADD -25 DUST TIGHT COIL HOUSING - NEMA 5 ADD -25 ADD -57 MANUAL RESET/SAFETY SHUT-OFF, NO VOLTAGE RELEASE. ADD -57 ADD -FL PIPE CONNECTION: -FL FLANGE ADD -FL

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are Sand Cast in Bronze rated 1200 psi. PISTON SPRINGS are 316 or 302 SS. BONNET ASSEMBLIES are 304 SS TUBES silver soldered to Brass BONNET and TUBE PLUG. PISTON ASSEMBLIES are Brass with Filled Teflon PISTON RINGS, Stainless Steel EXPANDERS, and Buna, EP, Fluorocarbon Or Virgin Teflon SEAT DISCS. PILOT ASSEMBLIES are 416 SS ARMATURE with a 316 SS PILOT POINT and 316 SS PINS.

SPECIALS: Teflon Coated Pistons & other Special Assemblies Available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory.

TERMS AND CONDITIONS OF SALE: See Back Cover of the List Price Schedule.

Page 34: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA

# Part Description Valve Type ¾” 1” 1 ¼” 1 ½” 2” 1 N. C. Bonn. Assm, D & D-2 74XP 74XP 83XP 83XP 76XP N. O. Bonn. Assm. DR & DR-2 74XPR 74XPR 83XPR 83XPR 76XPR2 Piston Spring ALL 37-2 37-2 37-2 37-2 37-2 HP Piston Spring ALL HP’s 37-1 37-1 37-1 37-1 37-1 3 SeatScrew ALL 31-x 31-x 31-x 31-x 31-x 4 Piston Assembly ALL P72 P72 P56-1 P56-1 P77-15 O-Ring ALL 2-228 2-228 2-235 2-235 2-2406 Piston Only ALL 72 72 56 56 77 7 N.C. Pilot Assm. D & D-2 P22-1 P22-1 P22-1 P22-1 P22-1 N.O. Pilot Assm. DR & DR-2 P32R6 P34R6 P32R6 P32R6 P32R68 Piston Ring & Exp. ALL P58 P58 P60 P60 P61 9 Seat Disc ALL 36-1x 36-1x 36-112x 36-112x 36-2x

10 DiscScrew ALL 27 27 53 53 80 11 Seat Ring ALL 26 26 n/a n/a n/a 12 Body ALL P70-1 P70-2 P48 P49 P75 13 Packing Retainer ALL 69 69 69 69 69 14 Packing ALL 16 16 16 16 16 15 Packing Gland ALL 15 15 15 15 15 16 Adjustment Stem ALL 2-1 2-1 2-1 2-1 2-1 17 Bottom Plug ALL 20 20 20 20 78 18 Coil Screw ALL 9 9 9 9 9 19 Nameplate ALL 44-x 44-x 44-x 44-x 44-x 20 N.C. Top Nip D 115-2 115-2 115-2 115-2 115-2 N.O. Top Nip DR 115-3 114-3 115-3 115-3 115-3 XP End Plate D-2 & DR-2 113 113 113 113 113

21 Coil Consult Factory or List Price Schedule 22 N.C. Coil Cover D 89 89 89 89 89 N.O. Coil Cover DR 89NO 89NO 89NO 89NO 89NO N.C. XP Coil Cover D-2 42NC 42NC 42NC 42NC 42NC N.O. XP Coil Cover DR-2 42NO 42NO 42NO 42NO 42NO Bolts D-2 & DR-2 9-4 9-4 9-4 9-4 9-4 Washers D-2 & DR-2 46-3 46-3 46-3 46-3 46-3

23 Coil Housing D & DR 87 87 87 87 87 XP Coil Housing D-2 & DR-2 41 41 41 41 41

Dimension A D 8.95 8.95 9.83 9.83 11.35 DR 9.91 9.91 10.80 10.80 12.30 D-2 9.05 9.05 9.99 9.99 11.50 DR-2 10.20 10.20 11.11 11.11 12.61 Dimension B D 7.15 7.15 7.71 7.71 8.75 DR 8.10 8.10 10.80 10.80 8.70 D-2 7.25 7.25 7.86 7.86 8.86 DR-2 8.40 8.40 8.99 8.99 9.99 End to End Length ALL 4.25 4.25 6.13 6.13 6.19

CV ALL 6.3 11.5 18.0 28.0 50.0

Bulletin 620-D Series

PERFORMANCE, ORDERING AND INSTALLATION GUIDE ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). —————————————————————————————————————————————————————————————————————————————————————-

FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. —————————————————————————————————————————————————————————————————————————————————————

OPERATION--PISTON PILOT OPERATED. MINIMUM PRESSURE DROP OF 5 PSI (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. —————————————————————————————————————————————————————————————————————————————————————

MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. —————————————————————————————————————————————————————————————————————————————————————

SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

1” Type D-3V

Valve Weight (lb) ¾” 1” 1 ¼” 1 ½” 2” D 12 13 24 26 30

DR 16 17 28 30 34 D-2 12 13 24 26 30

DR-2 16 17 28 30 34

Rev. A

Page 35: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. D

BULLETIN 900-J SERIES

1/8”-1” NPT

TYPE J Series

4707 Massachusetts Ave. - P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

2-WAY – CAST BRONZE BODIES - PACKLESS

VELVETROL INTERNAL PISTON PILOT OPERATED GENERAL PURPOSE SOLENOID VALVES - FULL PORT

NORMALLY CLOSED OR NORMALLY OPEN

FOR: GENERAL SERVICE-AIR-INERT GASES-WATER-OIL-STEAM PRESSURES: 0 TO 250 PSI MAXIMUM TEMPERATURE: -420°F TO 400°F. CLASS F OR N COILS MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 1" NPT FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in Price Schedule. Valves will be furnished for 0-125 PSI Air-Water and 120 VAC Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE J-3B J-3EP J-3T J-3V

GENERAL PURPOSE • AIR • WATER 0-125 or 0-250 PSI -3B BUNA, -3EP ETHYLENE PROPYLENE, -3T PTFE (TEFLON), -3V FLOUROCARBON (VITON) 220°F. Max. Fluid Temp. Class F Coils: 120, 240, 480 VAC 60 Hz, 32 Watts Max.

IN DEVELOPMENT

TYPE J4-3B J4-3EP J4-3T J4-3V

GENERAL PURPOSE • AIR • WATER • INERT GASES • OIL 0-125 or 0-250 PSI -3B BUNA, -3EP ETHYLENE PROPYLENE, -3T PTFE (TEFLON), -3V FLOUROCARBON (VITON) 300°F. Max. Fluid Temp. Class F. Non-Standard Coils Available With Voltage, Wattage, and Lead Wire Length To Your Specs.

IN DEVELOPMENT

TYPE J-1-3T J-1-3EP

STEAM & HOT AIR -3T to 125 psi & 356°F, -3EP to 50 psi & 300°F Max Pressure and Fluid Temps, Class N 120, 240, 480 VAC 60 Hz, 32 Watts Max.

IN DEVELOPMENT

TYPE J4-1-3T STEAM (to 125 psi) – HOT FLUIDS (to 400°F) SIMILAR TO J4 Series EXCEPT High Temp.

IN DEVELOPMENT

ADD -1 HIGH TEMP. (CLASS N) COILS – FLUID TEMP. TO 400°F. STEAM to 125 PSI. ADD -1

ADD -2 EXPLOSION PROOF COIL HOUSING – NEMA 7 ADD -2

ADD -24 WATER TIGHT COIL HOUSING - NEMA 4 ADD -24 ADD -25 DUST TIGHT COIL HOUSING - NEMA 5 ADD -25

ADD -57 MANUAL RESET – SAFETY SHUT-OFF, NO VOLTAGE RELEASE. ADD -57

ADD -9 SPECIAL CONSTRUCTION FOR CRYOGENIC SERVICE ADD -9

ADD -FL PIPE CONNECTION:-FL FLANGE ADD -FL

Page 36: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. D

Bulletin 900-J Series

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are Sand Cast in Bronze rated 400 psi WOG. PISTON SPRINGS are 316 or 302 SS. BONNET ASSEMBLIES are 304 SS TUBES silver soldered to Brass BONNET and TUBE PLUG. PISTON ASSEMBLIES are Brass with Filled Teflon PISTON RINGS, Stainless Steel EXPANDERS, and Brass SeatScrew with Flourocarbon or Virgin PTFE slug. SEAT DISCS are Buna, EP, Flourocarbon, and Virgin PTFE. PILOT ASSEMBLIES are 430 SS ARMATURE connected to a 316 SS PILOT POINT with a 410 SS CLIP and 316 SS RETAINER CAP.

SPECIALS: Teflon Leak Proof Seat Screws, Teflon Discs (Standard on all Steam Valves), Teflon Coated Pistons & other Special Assemblies Available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory.

See Price Schedule for "Terms and Conditions of Sale." (Back Cover) ———————————————————————————————————————————————————————————————————————————————————————————

PERFORMANCE, ORDERING AND

INSTALLATION GUIDE ———————————————————————— ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, & ELECTRICAL SPECIFICATIONS. ———————————————————————— FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. ————————————————————————OPERATION—SEMI-DIRECT LIFT PILOT OPERATED. NO MINIMUM PRESSURE DROP (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. ———————————————————————— MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NO LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. PTFE TAPE STRONGLY RECOMMENDED FOR ALL JOINTS. ———————————————————————— OPERATING PRESSURE: THE SOLENOID VALVE SHOULD BE ORDERED WITH THE MAXIMUM RATED PRESSURE CLOSEST TO THE ACTUAL PRESSURE THE VALVE WILL OPERATE IN. FOR EXAMPLE: IF YOUR APPLICATION IS FOR 40 PSI, ORDER A VALVE RATED TO 125 PSI NOT 250 PSI. ———————————————————————— SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

¾” Type J-3V

Page 37: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. D

The Explosionproof housing is constructed of two (2) machined, sand-cast gray iron parts bolted together, threaded onto the bonnet assembly and cemented in place. Once assembled, the housing will not rotate on the bonnet assembly. On valves with a union-style bonnet ring, the entire bonnet may be rotated with respect to the body. Consult factory for details. NEMA 4, NEMA 5, or NEMA 7 ratings are available with this housing.

Bulletin 900-J Series

* also -3B, -3EP, & -3T

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Val

ve S

ize

Bon

net

Ass

embl

y

Bon

net S

eal

Bon

net R

ing

Pist

on S

prin

g

Seat

Scre

w

Ass

embl

y

Pist

on

Ass

embl

y L

ift P

ilot

Ass

embl

y

Pist

on O

nly

Pist

on R

ing

& E

xpan

der

Seat

Dis

c

Gui

deN

ut

Bod

y

Coi

l Scr

ew

Nam

epla

te

Nip

Coi

l Cov

er

Coi

l

Coi

l Can

J-3V* J-3V* BOTH BOTH J-3V* J-3V* BOTH BOTH BOTH J-3V* BOTH BOTH BOTH BOTH J-3V J-3V BOTH BOTH 1/8 4032 2121x N/A 37-36 908-1x 407J3x 23-1 402 57 3612x 406B 400-8 9 44-1-1 1152 89 87 1/4 4032 2121x N/A 37-36 908-1x 407J3x 23-1 402 57 3612x 406B 400-4 9 44-1-1 1152 89 87 3/8 4032 2121x N/A 37-36 908-1x 407J3x 23-1 402 57 3612x 406B 400-1 9 44-1-1 1152 89 87 1/2 4032 2121x N/A 37-36 908-1x 407J3x 23-1 402 57 3612x 406B 400-2 9 44-1-1 1152 89 87 3/4 4132 2125x N/A 37-35 908-2x 417J3x 23-1 412 159 3634x 416 410 9 44-1-1 1152 89 87 1 4232 N/A 428 37-35 908-1x 427J3x 23-1 422 58 361x 429 420 9 44-1-1 1152 89

See List

Price Sched.

87

1b 7b 20 21 22a 23 23 24

Val

ve

Size

N

.C. X

P B

onne

t A

ssem

bly

N.C

. XP

Pilo

t A

ssem

bly

Coi

l E

ndpl

ates

C

oil

Spri

ng

N.C

. XP

Cov

er

XP

Bol

ts

XP

Was

hers

XP

Bas

e

Physical Dimensions of J-3B, J-3EP, J-3V and J-3T

Physical Dimensions of

J-3B-2, J-3EP-2, J-3V-2 and J-3T-2

J-3V-2 J-3V-2 J-3V-2 J-3V-2 J-3V-2 J-3V-2 J-3V-2 J-3V-2

CV

Fac

tor

A B C wt A B C wt 1/8 4032XP 26-1 113 37-2 42NC 9-4 46-3 41A 2.9 6.31 5.5 2.75 3 7 6.19 2.75 7 1/4 4032XP 26-1 113 37-2 42NC 9-4 46-3 41A 2.9 6.31 5.5 2.75 3 7 6.19 2.75 7 3/8 4032XP 26-1 113 37-2 42NC 9-4 46-3 41A 3.6 6.31 5.5 2.75 3 7 6.19 2.75 7 1/2 4032XP 26-1 113 37-2 42NC 9-4 46-3 41A 3.6 6.31 5.5 2.75 3 7 6.19 2.75 7 3/4 4132XP 26-1 113 37-2 42NC 9-4 46-3 41A 6.8 6.69 5.7 3.25 4 7.38 6.38 3.25 8 1 4232XP 26-1 113 37-2 42NC 9-4 46-3 41A

11.5 7.0 5.83 3.81 5

7.63 6.44 3.81 9

Page 38: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. D

Bulletin 900-J Series What is a Zero Differential Solenoid Valve?

A Zero Differential Solenoid Valve is one that requires no differential pressure* in the line to open the main port. This is accomplished by connecting the piston to the Magnetic Armature (or the Pilot, as it is sometimes called). See Fig. 1. Therefore when the coil is energized the pilot opens and if the pressure differential is great enough to open the main port, it opens. However, if the pressure differential is low, the Pilot will pull the piston up and hence open the main port. A standard Solenoid valve does not have the connection stated above, and therefore requires several psi of differential pressure to open the main port. See Fig. 2.

When to use a J. D. Gould Company Type J Zero Differential Solenoid Valve?

• For “Closed Loop” Systems • For Gravity Feed Applications • When a “Steam Trap” is being used • For “Dead End” Systems • Wherever Low Pressure Differentials occur

* Differential Pressure is the difference in fluid pressure before and after the valve. (Pin – Pout)

Fig. 1: Zero Differential Fig. 2: Standard

Page 39: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. C

BULLETIN 40-EF

4707 Massachusetts Ave. • P.O. Box 18128 Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

4” 150# Flange

TYPE EF & EFR

2-WAY - CAST DUCTILE IRON BODIES (ASTM A-395)- PACKLESS

VELVETROL INTERNAL PISTON PILOT OPERATED GENERAL PURPOSE SOLENOID VALVES

NORMALLY CLOSED WHEN DE-ENERGIZED

FOR: GENERAL PURPOSE - AIR - WATER - LIGHT OIL SIZE: 4” CLASS 150 FLANGE (Mates with Class 125 Flange) SHUTOFF: LEAKPROOF SEAL PRESSURES: 5 PSI MINIMUM TO 250 PSI MAXIMUM FULL PORT TEMPERATURE: FLUIDS TO 180°F. CLASS F COILS MOUNTING: INSTALL HORIZONTALLY WITH COIL UPRIGHT AND ON TOP

SIZE 4" FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in Price Schedule. Valves will be furnished for 5-125 PSI and 120 VAC Unless Otherwise Specified. For

non-corrosive fluids with viscosity not exceeding 400 SSU. Molded coils for most AC or DC voltages.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE EF-3B EF-3EP EF-3V EF-3T

WATER / SELECTED LIQUIDS (Consult Factory) 5-250 PSI. AIR / INERT GASES 5-140 PSI. 180°F. Max. Fluid, Class B 12, 24, 55, 120, 240, 480, 550 VAC 60 Hz , 26 Watts Max. 6, 12, 24, 32, 48, 115, 230 VDC, 24 Watts

TYPE EFR-3B EFR-3EP EFR-3V EF-3T

ADD -3B, -3T, -3V, -3EP

LEAKPROOF PILOT SEAT: -3B BUNA, -3EP ETHYLENE- PROPYLENE, -3T PTFE, -3V FLOUROCARBON (VITON)

ADD -3B, -3T, -3V, -3EP

ADD –2 EXPLOSION PROOF, WATER TIGHT, AND DUST TIGHT COIL HOUSING – NEMA 4, NEMA 5 & NEMA 7. ADD -2

ADD –24 SAME AS -2 ADD -24 ADD –25 SAME AS -2 ADD -25 ADD –230 CLASS 1, GROUP D FOR GASOLINE, DIESEL FUEL, #1 AND

#2 FUEL OIL ADD -230 ADD -MO MANUAL OPEN OPTION ADD -MO ADD -TA TIMING ADJUSTMENT ADD -TA

FLOW FACTORS: SEE REVERSE SIDE CONSTRUCTION:

CLASS B COILS are water-resistant, Fungusproof, Transfer Molded with 18" Leads. BODIES are rated to 250 psi and Cast of Ductile Iron with ANSI Class 150 flanges. BONNET PLATES are rated to 250 psi and Cast of Ductile Iron. PISTON SLEEVES are Stainless Steel and fit into the Bodies. BONNET ASSEMBLIES have Stainless Steel PLUNGER TUBES silver soldered to the Brass BONNETS. PISTON ASSEMBLIES have Cast Bronze PISTONS with Brass GUIDE POSTS, FILLED PTFE PISTON RINGS, and Stainless Steel Expanders. SEAT DISCS, PILOT SEATS, and SEALS are Buna, EP, PTFE, or Flourocarbon. PILOT VALVES are Stainless Steel.

See Price Schedule for "Terms and Conditions of Sale."

Page 40: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. C

Bulletin 40-EF

PERFORMANCE, ORDERING AND INSTALLATION GUIDE ———————————————————————————————————————————————————— ORDERING DATA-----SPECIFY PIPE SIZE, TYPE, MATERIAL HANDLED, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE, IF ANY. FLOW CHARACTERISTICS----SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS BELOW AND BULLETIN CP-1. ———————————————————————————————————————————————————— OPERATION: Piston Pilot Operated. Minimum pressure drop of 5 psi (∆P) required across valve for operation. MOUNTING: Mount in horizontal line with coil vertical and on top. Install 40 mesh strainer (not larger) ahead of valve. Check for proper coil voltage. Make sure that the flow arrow on valve body is pointing in the direction of flow. SERVICING: Solenoid Valves should be frequently checked for operation, cleanliness, & internal wear - Repair Kits are Factory Available --Give Size, Type, Serial Number or Operating Data (voltage, pressure, etc.)

#

PART NUMBER

PART DESCRIPTION

1 9 Coil Screw 2 44-1 Name Plate 3 115-2 Top Nip 4 89 Coil Cover

5 See Price Schedule Coil

6 87 Bottom Assm 7 403-2 Bonnet Assm

8 2-121B Bonnet Assm Seal

9 901-1 Bonnet Plate

10 2-163B Bonnet Plate Seal

11 903 Piston Sleeve 12 P902-2 Piston Assm

13 24-1 Pilot Valve Assm

14 415-31V SeatScrew Assm

15 902-2 Piston 16 905-2 Guide Post 17 2-158B Piston Rings

18 461-2 Seat Disc Retainer

19 36-4B Seat Disc 20 900 Body

21 9-26 Bonnet Plate Bolts

21 6-20 Bonnet Plate Nuts

21 46-8 Bonnet Plate Lock Washers

PHYSICAL DIMENSIONS A 14.3 in. B 9.8 in. C 11.5 in. Weight 120 lbs CV 195

Page 41: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN -9 CRYOGENICS

1/8”-3” NPT

TYPES Q, M, J, A, F, G, GX, K, & KX

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

2-WAY BRASS, BRONZE, OR STAINLESS STEEL BODIES WITH TEFLON™

SEATS AND SEALS, PACKLESS VELVETROL INTERNAL PISTON PILOT OPERATED, OR DIRECT LIFT SOLENOID VALVES FOR CRYOGENIC

SERVICE. NORMALLY CLOSED OR NORMALLY OPEN - FULL OR FRACTIONAL PORT

FOR: INERT CRYOGENIC GASES (N2, CO2, ARGON, etc.) PRESSURES: 0 TO 1200 PSI MAXIMUM TEMPERATURE: -420°F. MIN. FLUID TEMP. CLASS N COILS MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" – 3" NPT FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for 120VAC, 60hz Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE Q-9-3T 5-150, 10-400 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE QR-9-3T

TYPE J-9-3T 0-250 PSI 6, 12, 24, 48, 115, 230 VDC 120, 240, 480 VAC 60 Hz.

n/a

TYPE K-9-3T TYPE K-9

5-150 PSI, 10-400 PSI, 20-1000 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE KR-9-3T TYPE KR-9

TYPE KX-9-3T TYPE KX-9

5-150 PSI, 10-300 PSI (Normally Open to 150 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE KRX-9-3T TYPE KRX-9

TYPE A-9-3T TYPE A-9

5-150 PSI, 10-400 PSI, 20-1200 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE AR-9-3T TYPE AR-9

TYPE F-9-3T TYPE F-9

0-600 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE FR-9-3T TYPE FR-9

TYPE G-9-3T TYPE G-9

0-600 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE GR-9-3T TYPE GR-9

TYPE GX-9-3T TYPE GX-9

0-300 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE GRX-9-3T TYPE GRX-9

ADD -2, -24, -25 Designates Coil Enclosure as NEMA 7 (-2), NEMA 4 (-24), or NEMA 5 (-25) on all Types listed above. ADD -2, -24, -25

TYPE M-9-3T 5-125, 10-250 PSI 24, 120, 240, 480 VAC (50/60 Hz), 26 Watts Max. 6, 12, 24, 48, 115, 230 VDC, 24 Watts Max.

n/a

Page 42: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

Bulletin 9-M, Q, M, J, A, F, G, GX, K, & KX Series CONSTRUCTION:

All valves are provided with CLASS N COILS that are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads and have a ½” NPT Conduit Connector. All (except Type M) are available with NEMA 1, 4, 5 or 7 COIL ENCLOSURES. Type M-3T-T-9 & M4-3T-T-9 COIL ASSEMBLIES are completely encapsulated and are NEMA 4X rated. BODIES (except Types F & G) are Globe Style with Union Bonnets (1” & above), rated to pressures shown above. All (except Types K, F & G) are Cast in Bronze. Types K & KX are Investment Cast in CF8M Stainless Steel. Types F, G & GX BODIES are 90° bodies of Brass, 303 SS and 316 SS respectively. PISTON SPRINGS are Stainless Steel. BONNET ASSEMBLIES for Brass valves are 304 SS TUBES, Brass BONNETS, and Brass TUBE PLUGS silver soldered together. BONNET ASSEMBLIES for Stainless Steel valves are 304 (or 316 for “X”) SS TUBES, 303 (or 316 for “X”) BONNETS, and 303 (or 316 for “X”) TUBE PLUGS welded together. PISTON ASSEMBLIES for Bronze valves are Brass with Filled PTFE PISTON RINGS and SS EXPANDERS. PISTON ASSEMBLIES for Stainless Steel valves are 304 (or 316 for “X”) with Filled PTFE PISTON RINGS and SS EXPANDERS. SEAT DISCS and PILOT DISC are PTFE. PILOT ASSEMBLIES are 416 SS ARMATURE with a 316 SS PILOT POINT and 316 SS PINS (Types J-3T-T-9 & Q-3T-T-9) and Solid 416 SS (Type M-3T-T-9). Stainless Steel “X” valves use a 316 JACKETED PILOT ASSEMBLY.

SPECIALS:

All Metal Pilot SeatScrews are available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory

OPERATION—All Type M, Q & J Valves are PISTON PILOT OPERATED. Minimum pressure drop of 5 psi (∆P) is required across valve for operation of Types M & Q. Type J is PISTON PILOT OPERATED, but requires no minimum pressure differential (∆P). Types F & G are DIRECT ACTING, with fractional port sizes. MOUNTING--Mount in horizontal line with coil vertical and on top. Install 40 mesh strainer (not larger) ahead of valve. Check for proper coil voltage. Make sure that the flow arrow on valve body is pointing in the direction of flow. SERVICING--Solenoid Valves should be frequently checked for operation, cleanliness, & internal wear - Repair Kits are Factory Available --Give Size, Type, Serial Number or Operating Data (voltage, pressure, etc.) GENERAL INFORMATION--These valves are designed specifically to handle the unique requirements that ultra low temperatures demand. Built especially for Cryogenic service, these valves contain all PTFE seats and seals. The internal components are specially designed to function through any boil off, or phase change in the fluid. They also require special handling to ensure that they are both clean and dry before they leave the factory. For additional information, such as individual part lists or dimensions may be found on Bulletins 200-Q, 120-M, 900-J, 400-A, 800-K, 4000-FG, and 5000-GX

Page 43: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN -57 MANUAL RESET

1/8”-3” NPT & 4” Fl

TYPES Q, J, A, B, D, F, G, GX, K, KX, EF,

AD, QD, KD

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

2-WAY BRASS, BRONZE, STAINLESS STEEL, & DUCTILE IRON BODIES, VELVETROL INTERNAL PISTON PILOT OPERATED, DIRECT LIFT OR ZERO DIFFERENTIAL SOLENOID VALVES FOR GENERAL SERVICE.

NORMALLY CLOSED OR NORMALLY OPEN - FULL OR FRACTIONAL PORT

FOR: SYSTEMS REQUIRING A MANUAL RESET OF THE VALVE AFTER POWER LOSS PRESSURES: 0 TO 1200 PSI MAXIMUM (DEPENDING ON TYPE) TEMPERATURE: -40°F. to 300°F MAX. FLUID TEMP • CLASS F COILS MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" – 3" NPT FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for 120VAC, 60hz Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE Q-3B-57, (also -3EP, -3V, -3T)

5-150, 10-400 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE QR-3B-57, (also -3EP, -3V, -3T)

TYPE J-3B-57 (also -3EP, -3V, -3T)

0-250 PSI 6, 12, 24, 48, 115, 230 VDC 120, 240, 480 VAC 60 Hz.

N/A

TYPE A-57 (also -3B, -3EP, -3V, -3T)

5-150 PSI, 10-400 PSI, 20-1000 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE AR-57 (also -3B, -3EP, -3V, -3T)

TYPE B-57 (also -3B, -3EP, -3V, -3T)

5-150 PSI, 10-300 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE BR-57 (also -3B, -3EP, -3V, -3T)

TYPE D-57 (also -3B, -3EP, -3V, -3T)

5-150 PSI, 10-400 PSI, 20-1200 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE DR-57 (also -3B, -3EP, -3V, -3T)

TYPE F-57 (also -3B, -3EP, -3V, -3T)

0-600 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE FR-57 (also -3B, -3EP, -3V, -3T)

TYPE G-57 (also -3B, -3EP, -3V, -3T)

0-600 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE GR-57 (also -3B, -3EP, -3V, -3T)

TYPE GX-57 (also -3B, -3EP, -3V, -3T)

0-300 PSI (Normally Open to 300 PSI) 12, 24, 120, 240, 480 VAC 50-60 Hz 6, 12, 24, 48, 115, 230 VDC

TYPE GRX-57 (also -3B, -3EP, -3V, -3T)

TYPE K-57 (also -3B, -3EP, -3V, -3T)

5-125, 10-250 PSI 24, 120, 240, 480 VAC (50/60 Hz), 26 Watts Max. 6, 12, 24, 48, 115, 230 VDC, 24 Watts Max.

TYPE KR-57 (also -3B, -3EP, -3V, -3T)

TYPE KX-57 (also -3B, -3EP, -3V, -3T)

5-125, 10-250 PSI 24, 120, 240, 480 VAC (50/60 Hz), 26 Watts Max. 6, 12, 24, 48, 115, 230 VDC, 24 Watts Max.

TYPE KRX-57 (also -3B, -3EP, -3V, -3T)

Page 44: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN -57 MANUAL RESET

CONSTRUCTION: Valves are provided with CLASS F COILS that are Waterproof, Fungusproof, Molded of Filled Polyester, wired through a relay and a switch. All electrical components and associated wiring are contained in NEMA 1, COIL ENCLOSURES (junction box). For additional information, such as individual part lists or dimensions please refer to Bulletins 200-Q, 900-J, 400-A, 600-B, 620-D, 800-K, 1001-QKD, 4000-FG, and 5000-GX.

SPECIALS: Consult Factory

———————————————————————————————————————————————————————————————————————————————————————————————————————

OPERATION--All Type Q, A, B, D, & EF Valves are PISTON PILOT OPERATED. Minimum pressure drop of 5 psi (∆P) is required across valve for proper operation. Type J is a ZERO DIFFERENTIAL valve, and requires no minimum pressure differential (∆P). Types F, G. & GX are DIRECT ACTING, with fractional port sizes. Types AD, QD & KD are DIRECT ACTING, full port, but with limited pressure range. MOUNTING--Mount in horizontal line with coil vertical and on top. Install 40 mesh strainer (not larger) ahead of valve. Check for proper coil voltage. Make sure that the flow arrow on valve body is pointing in the direction of flow. SERVICING--Solenoid Valves should be frequently checked for operation, cleanliness, & internal wear - Repair Kits are Factory Available --Give Size, Type, Serial Number or Operating Data (voltage, pressure, etc.) GENERAL INFORMATION--These valves are designed specifically to require human intervention to start. Once the power to the valve is interrupted, whether by normal shutdown or by power outage, the valve will remain in an off condition until power is re-supplied, AND the RESET BUTTON on the front of the coil housing de-pressed

Wiring Schematic for Manual Reset Coil

Photo Showing Reset Button Location

Photo of Internal Coil Housing Detail

Page 45: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. B

BULLETIN 800-K SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/8”-2” NPT

TYPES K, KX, KR, & KRX

2-WAY – INVESTMENT CAST CF8M BODIES - PACKLESS

VELVETROL INTERNAL PISTON PILOT OPERATED GENERAL PURPOSE SOLENOID VALVES - FULL PORT

NORMALLY CLOSED OR NORMALLY OPEN

FOR: GENERAL SERVICE-AIR-WATER-STEAM-INERT GASES CORROSIVE FLUIDS (CONSULT FACTORY)

PRESSURES: 5 PSI DIFFERENTIAL MINIMUM TO 1000 PSI MAXIMUM TEMPERATURE: -420°F TO 450°F. CLASS F OR N COILS MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 2" NPT FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in Price Schedule. Valves will be furnished for 5-150 PSI and 120 VAC Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE K TYPE K-3T

5-150, 10-300 PSI; 300°F. MAX. FLUID, CLASS F STANDARD COILS: 120, 240, 480 VAC 60 Hz, 14W MAX. NON-STANDARD COILS AVAILABLE WITH VOLTAGE, WATTAGE, AND LEAD WIRE LENGTH TO YOUR SPECS.

TYPE KR TYPE KR-3T

TYPE KS FOR LIQUIDS TO 700 PSI, NON-VOLATILE INERT GASES TO 400 PSI. TEMPERATURE TO 300°F N/A

TYPE KST FOR LIQUIDS TO 1000 PSI, TEMPERATURE TO 300°F N/A

TYPE KX SIMILAR TO TYPE K, EXCEPT 5-60 OR 5-150 PSI AND ALL WETTED PARTS ARE 316 SS OR PTFE (TEFLON) TYPE KRX

TYPE KX-62-3EP-EP

SPECIAL CONSTRUCTION FOR DEIONIZED WATER SERVICE – ETHYLENE PROPYLENE SEALS AND ALL WELDS PASSIVATED.

TYPE KRX-62-3EP-EP

TYPE KXS SIMILAR TO KX EXCEPT 10-300 PSI (Norm. Open to 150 PSI) TYPE KRX

ADD –1 HIGH TEMP. (CLASS N) COILS - FLUID TEMP. TO 450°F. 200 PSI STEAM. ADD -1

ADD –2 EXPLOSION PROOF COIL HOUSING - NEMA 7 ADD -2 ADD -3, -3T, -3V -3EP

LEAKPROOF PILOT SEAT: -3 O-RING (BUNA, ETHYLENE- PROPYLENE, FLOUROCARBON (VITON), & PTFE), -3T PTFE, -3V FLOUROCARBON (VITON)

ADD -3, -3T, -3V -3EP

ADD –24 WATER TIGHT, EXPLOSION PROOF COIL HOUSING. NEMA 4 & 7 ADD -24

ADD –25 DUST TIGHT, EXPLOSION PROOF COIL HOUSING. NEMA 5 & 7 ADD -25

ADD –58 MANUAL RESET – SAFETY SHUT-OFF, NO VOLTAGE RELEASE. SEE BULLETIN 810-K58 ADD -58

ADD -81, -84 -81 SLOW CLOSE (REDUCES WATER HAMMER) -84 QUICK CLOSE (BOTH FACTORY SETUPS) ADD -81, -84

ADD -9 SPECIAL CONSTRUCTION FOR CRYOGENIC APPLICATIONS. FLUID TEMP. TO –420°F ADD -9

ADD –230 SPECIAL CONSTRUCTION FOR GASOLINE AND DIESEL FUEL. SEE BULLETIN 230-K ADD -230

ADD –SW, -FL PIPE CONNECTION: -SW SOCKET WELD, -FL FLANGE ADD -SW, -FL

Page 46: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA

Bulletin 800-K Series

CONSTRUCTION: Type K & KX: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are Investment Cast in CF8M Stainless Steel. PISTON SPRINGS are 316 or 302 SS. Type K: BONNET ASSEMBLIES are 304 SS TUBES welded to 303 SS BONNET and 303 SS TUBE PLUG. PISTON ASSEMBLIES are 303 SS with Glass & Moly Filled PTFE PISTON RINGS and 316 SS EXPANDERS. SEAT DISCS are Buna, EP, Flourocarbon, and Virgin PTFE. PILOT ASSEMBLIES are 416 SS ARMATURE with a 316 SS PILOT POINT and 316 SS PINS. Type KX: BONNET ASSEMBLIES are 316 SS TUBES welded to 316 SS BONNET and 316 SS TUBE PLUG. PISTON ASSEMBLIES are 316 SS with Glass & Moly Filled PTFE PISTON RINGS and 316 SS EXPANDERS. SEAT DISCS are Virgin PTFE. PILOT ASSEMBLIES are 316 SS JACKET welded over plain carbon steel CORE.

1/8”–1” GLOBE STYLE BODY WITH UNION BONNET 1-1/4”–2” GLOBE STYLE BODY WITH BOLT-DOWN BONNET

See Price Schedule for "Terms and Conditions of Sale." ———————————————————————————————————————————————————————————————————————————————————————————

PERFORMANCE, ORDERING AND

INSTALLATION GUIDE

—————————————————————— ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). —————————————————————— FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. ——————————————————————OPERATION--PISTON PILOT OPERATED. MINIMUM PRESSURE DROP OF 5 PSI (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. —————————————————————— MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. —————————————————————— OPERATING PRESSURE: THE SOLENOID VALVE SHOULD BE ORDERED WITH THE MAXIMUM RATED PRESSURE CLOSEST TO THE ACTUAL PRESSURE THE VALVE WILL OPERATE IN. FOR EXAMPLE: IF YOUR APPLICATION IS FOR 40 PSI, ORDER A VALVE RATED 5-125 PSI NOT 10-250 PSI. —————————————————————— SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

¾” Type K-3T

Rev. B

Page 47: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA

Bulletin 800-K Series

1 1a 2 3 4 5 6 7 7a 8 9 10 11

Val

ve S

ize

N.C

. Bon

net

Ass

embl

y

N.O

. Bon

net

Ass

embl

y

Bonn

et B

olts

Bo

nnet

Rin

g

Pist

on S

prin

g

Seat

Scre

w

Pist

on

Ass

embl

y

N.C

. Pilo

t A

ssem

bly

N.O

. Pilo

t A

ssem

bly

Pist

on O

nly

Pist

on R

ing

&

Expa

nder

Seat

Disc

Gui

deN

ut

or

Dis

cScr

ew

K KX KR KRX ALL ALL ALL K/KR KX/KRX K/KR KX/KRX K KX KR KRX K/KR KX/KRX ALL ALL K/KR KX/KRX1/8 190 190316 190R 190R316 N/A 192 37-14 415-x2x 415-x3x 853 8531 21-1 2421 32R1K 242R4 402-2 402-3 57 3612x 851 406S 1/4 190 190316 190R 190R316 N/A 192 37-14 415-x2x 415-x3x 853 8531 21-1 2421 32R1K 242R4 402-2 402-3 57 3612x 851 406S 3/8 190 190316 190R 190R316 N/A 192 37-14 415-x2x 415-x3x 853 8531 21-1 2421 32R1K 242R4 402-2 402-3 57 3612x 851 406S 1/2 190 190316 190R 190R316 N/A 192 37-14 31-x-303 31x316 187 187316 21-1 2421 32R1K 242R4 187 187316 189 3612x 188 1883163/4 197 197316 197R 197R316 N/A 199 37-14 31-x-303 31x316 194 194316 21-1 2421 32R1K 242R4 194 194316 196 3634x 195 1953161 204 204316 204R 204R316 N/A 206 37-14 31-x-303 31x316 201 201316 21-1 2421 32R1K 242R4 201 201316 203 361x 202 202

1-1/4 218 218316 218R 218R316 9-18 N/A 37-2 31-x-303 31x316 214 214316 22-1 2422 32R1K 242R6 214 214 216 36112x 215 215 1-1/2 218 218316 218R 218R316 9-18 N/A 37-2 31-x-303 31x316 214 214316 22-1 2422 32R1K 242R6 214 214 216 36112x 215 215

2 224 224316 224R 224R316 9-19 N/A 37-2 31-x-303 31x316 220 220316 22-1 2422 32R1K 242R6 220 220 222 362x 221 221

12 13 14 15 15a 16 16a 17 18 19

Val

ve S

ize

Body

Coi

l Scr

ew

Nam

epla

te

N.C

. Nip

N.O

. Nip

N

.C. C

oil

Cov

er

N.O

. Coi

l C

over

Coi

l

Coi

l Can

O-R

ing

ALL ALL ALL K/KX KR KRX K/KX KR

KRX ALL K/KX ALL

1/8 850 9 44-1-1 1152 1153 89 89NO 87 N/A 1/4 850-1 9 44-1-1 1152 1153 89 89NO 87 N/A 3/8 850-2 9 44-1-1 1152 1153 89 89NO 87 N/A 1/2 186 9 44-1-1 1152 1153 89 89NO 87 N/A 3/4 193 9 44-1-1 1152 1153 89 89NO 87 N/A 1 200 9 44-1-1 1152 1153 89 89NO 87 N/A

1-1/4 213 9 44-1-1 1152 1153 89 89NO 87 2-1511-1/2 261 9 44-1-1 1152 1153 89 89NO 87 2-151

2 219 9 44-1-1 1152 1153 89 89NO

Consult Factory

or List

Price Sched.

87 2-154

Valve Dimensions

N. C. N. O.

Val

ve S

ize

CV

Fac

tor

A B C wtlbs A B C wt

lbs1/8 6.03 2.63 5.34 3 7.03 2.63 6.34 4 1/4 6.03 2.63 5.34 3 7.03 2.63 6.34 4 3/8 6.03 2.63 5.34 3 7.03 2.63 6.34 4 1/2 3.0 6.75 3.13 5.88 4 7.75 3.13 6.88 4 3/4 6.0 7.02 3.75 5.88 4 8.02 3.75 6.88 5 1 11.0 7.44 4.16 6.19 5 8.44 4.16 7.19 5

1-1/4 17.0 8.56 6.13 6.94 11 9.56 6.13 7.94 121-1/2 25.0 8.56 6.13 6.94 11 9.56 6.13 7.94 12

2 45.0 9.38 6.45 7.39 17 10.38 6.45 8.39 17

T

1-1/2” Type KR-3

Rev. B

Page 48: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN US

Bulletin 800-K Series

1b 1c 7b 7c 20 21 22 23 24 V

alve

Siz

e

N.C

. XP

Bonn

et

Ass

embl

y

N.O

. XP

Bonn

et

Ass

embl

y

N.C

. XP

Pi

lot

Ass

m

N.O

. XP

Pi

lot

Ass

m

Coi

l En

dpla

tes

Coi

l Sp

ring

N.C

. XP

Cov

er

N.O

. XP

Cov

er

XP

Bolts

XP

Was

hers

XP

Base

K2 KX2 KR2 KRX2 K2 KX2 KR2 KRX2 K2/KX2 KR2/KRX2

K2/KX2 KR2/KRX2

K2 KX2

KR2 KRX2

K2/KX2 KR2/KRX2

K2/KX2 KR2/KRX2

K2/KX2 KR2/KRX2

1/8 190XP 190XP316 190RXP 190RXP316 25-1 2421 P32R6K 242R8 113 37-2 42NC 42NO 9-4 46-3 41A 1/4 190XP 190XP316 190RXP 190RXP316 25-1 2421 P32R6K 242R8 113 37-2 42NC 42NO 9-4 46-3 41A 3/8 190XP 190XP316 190RXP 190RXP316 25-1 2421 P32R6K 242R8 113 37-2 42NC 42NO 9-4 46-3 41A 1/2 190XP 190XP316 190RXP 190RXP316 25-1 2421 P32R6K 242R8 113 37-2 42NC 42NO 9-4 46-3 41A 3/4 197XP 197XP316 197RXP 197RXP316 25-1 2421 P32R6K 242R8 113 37-2 42NC 42NO 9-4 46-3 41A 1 204XP 204XP316 204RXP 204RXP316 25-1 2421 P32R6K 242R8 113 37-2 42NC 42NO 9-4 46-3 41A

1-1/4 218XP 218XP316 218RXP 218RXP316 22-1 2422 P32R6K 242R10 113 37-2 42NC 42NO 9-4 46-3 41A 1-1/2 218XP 218XP316 218RXP 218RXP316 22-1 2422 P32R6K 242R10 113 37-2 42NC 42NO 9-4 46-3 41A

2 224XP 224XP316 224RXP 224RXP316 22-1 2422 P32R6K 242R10 113 37-2 42NC 42NO 9-4 46-3 41A

size A B C wt size A B C wt 1/8 6.56 2.63 5.88 7 1/8 7.69 2.63 7.00 8 1/4 6.56 2.63 5.88 7 1/4 7.69 2.63 7.00 8 3/8 6.56 2.63 5.88 7 3/8 7.69 2.63 7.00 8 1/2 7.30 3.13 6.44 7 1/2 8.41 3.13 7.54 8 3/4 7.56 3.75 6.44 8 3/4 8.68 3.75 7.54 9 1 8.00 4.16 6.75 9 1 9.10 4.16 7.85 10

1-1/4 9.10 6.13 7.50 15 1-1/4 10.22 6.13 8.60 16 1-1/2 9.10 6.13 7.50 15 1-1/2 10.22 6.13 8.60 16

2 9.92 6.45 7.94 20 Phys

ical

Dim

ensi

ons The Explosionproof housing is constructed of two (2)

machined, sand-cast gray iron parts bolted together, threaded onto the bonnet assembly and rigidly cemented in place. Once assembled the housing will not rotate. NEMA 4, NEMA 5, or NEMA 7 ratings are available with this housing.

2 11.04 6.45 9.05 21 Phys

ical

Dim

ensi

ons

T T

1-1/2” Type K-2-3

A

3/4” Type KR-2-3

Rev. B

Page 49: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 230-K SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/8”-2” NPT

TYPES K-230& KR-230

2-WAY – INVESTMENT CAST CF8M BODIES - PACKLESS

VELVETROL INTERNAL PISTON PILOT OPERATED SAFETY SOLENOID VALVES FOR HAZARDOUS LOCATIONS

NORMALLY CLOSED OR NORMALLY OPEN - FULL PORT

FOR: CLASS1, GROUP D FOR GASOLINE, DIESEL FUEL, #1 AND #2 FUEL OIL PRESSURES: 5 PSI DIFFERENTIAL MINIMUM TO 150 PSI MAXIMUM TEMPERATURE: 77°F. MAX. AMBIENT TEMP. CLASS F, 220°F MAX FLUID MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 2" NPT FULL PORT

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in Price Schedule 500 ST. Valves will be furnished for 5-150 PSI and 120 VAC Unless Otherwise Specified.

NORMALLY CLOSED-- --NORMALLY OPEN

TYPE K-230 5-150 PSI; 220°F. Max. Fluid, Class F 120, 240, 480 VAC 60 Hz, 14 Watts Std. Other Voltages Available. TYPE KR-230

ADD -81, -84 -81 SLOW CLOSE (REDUCES WATER HAMMER) -84 QUICK CLOSE (BOTH FACTORY SETUPS) ADD –81, 84

ADD -SW, -FL PIPE CONNECTION: -SW SOCKET WELD, -FL FLANGE ADD –SW, -FL CONSTRUCTION:

CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are rated to 2500 psi, Investment Cast in CF8M Stainless Steel. PISTON SPRINGS are 316 or 302 SS. BONNET ASSEMBLIES are 304 SS TUBES welded into a 303 SS or CF8M SS BONNET with a 303 SS or 316 SS TUBE PLUG. PISTON ASSEMBLIES are 303 SS, 316 SS, or CF8M with Filled PTFE PISTON RINGS and 316 SS EXPANDERS. SEAT DISCS are Flourocarbon. PILOT ASSEMBLIES are 416 SS ARMATURE with a 316 SS PILOT POINT and 316 SS PINS. 1/8”–1” GLOBE STYLE BODY WITH UNION BONNET 1-1/4”–2” GLOBE STYLE BODY WITH BOLT-DOWN BONNET

See List Price Schedule for "Terms and Conditions of Sale" (Back Cover) ——————————————————————————————————————————————————

PERFORMANCE, ORDERING AND INSTALLATION GUIDE

ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). ——————————————————————————————————————————————————————————————— FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. ——————————————————————————————————————————————————————————————— OPERATION--PISTON PILOT OPERATED. MINIMUM PRESSURE DROP OF 5 PSI (∆P) IS REQUIRED ACROSS VALVE FOR OPERATION. ——————————————————————————————————————————————————————————————— MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

Page 50: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED I

Bulletin 230-K Series

1b 1c 2 3 4 5 6 7b 7c 8 9 10 11 12 13 14 17 19 20 21 V

alve

Siz

e

N. C

. Bon

n.

Ass

embl

y

N. O

. Bon

n.

Ass

embl

y B

onn.

B

olts

B

onn.

Rin

g Pi

ston

Sp

ring

Seat

Sc

rew

Pist

on

Ass

embl

y N

.C. P

ilot

Ass

embl

y N

. O. P

ilot

Ass

embl

y Pi

ston

O

nly

Pisto

n R

ing

& E

xpan

der

Seat

Dis

c

Gui

deN

ut/

Dis

kScr

ew

Bod

y

Coi

l Scr

ew

Nam

epla

te

Coi

l

O-R

ing

Coi

l E

ndpl

ates

C

oil

Spri

ng

K230 KR230 ALL ALL ALL ALL ALL K230 KR230 ALL ALL ALL ALL ALL ALL ALL ALL ALL K230 KR230 1/8 190XP 190RXP N/A 192 37-14 415-32V TBD 25-1 P32R6K 402-2 57 3612V 851 850 9 4434 N/A 113 37-2 1/4 190XP 190RXP N/A 192 37-14 415-32V TBD 25-1 P32R6K 402-2 57 3612V 851 850-1 9 4434 N/A 113 37-2 3/8 190XP 190RXP N/A 192 37-14 415-32V TBD 25-1 P32R6K 402-2 57 3612V 851 850-2 9 4434 N/A 113 37-2 1/2 190XP 190RXP N/A 192 37-14 31-3-V303 187230 25-1 P32R6K 187 189 3612V 188 186 9 4434 N/A 113 37-2 3/4 197XP 197RXP N/A 199 37-14 31-3-V303 194230 25-1 P32R6K 194 196 3634V 195 193 9 4434 N/A 113 37-2 1 204XP 204RXP N/A 206 37-14 31-3-V303 201230 25-1 P32R6K 201 203 361V 202 200 9 4434 N/A 113 37-2

1-1/4 218XP 218RXP 9-18 N/A 37-2 31-3-V303 214230 22-1 P32R6K 214 216 36112V 215 213 9 4434 2-151 113 37-2 1-1/2 218XP 218RXP 9-18 N/A 37-2 31-3-V303 214230 22-1 P32R6K 214 216 36112V 215 261 9 4434 2-151 113 37-2

2 224XP 224RXP 9-19 N/A 37-2 31-3-V303 220230 22-1 P32R6K 220 222 362V 221 219 9 4434

Consult Factory or Page

10 of the List Price

Sched.

2-154 113 37-2

22 23 24 Normally Closed Normally Open

N.C

. XP

Cov

er

N.O

. XP

Cov

er

Bol

ts

Was

hers

XP

Bas

e

Val

ve S

ize

A B C Ship

W

eigh

t

Val

ve S

ize

A B C Ship

W

eigh

t

K230 KR230 ALL ALL ALL (in) (in) (in) (lbs) (in) (in) (in) (lbs) 42NC 42NO 9-4 46-3 41A 1/8 6.56 2.63 5.88 1/8 7.69 2.63 7.00 42NC 42NO 9-4 46-3 41A 1/4 6.56 2.63 5.88 1/4 7.69 2.63 7.00 42NC 42NO 9-4 46-3 41A 3/8 6.56 2.63 5.88 3/8 7.69 2.63 7.00 42NC 42NO 9-4 46-3 41A 1/2 7.30 3.13 6.44 1/2 8.41 3.13 7.54 42NC 42NO 9-4 46-3 41A 3/4 7.56 3.75 6.44 3/4 8.68 3.75 7.54 42NC 42NO 9-4 46-3 41A 1 8.00 4.16 6.75 1 9.10 4.16 7.85 42NC 42NO 9-4 46-3 41A 1-1/4 9.10 6.13 7.50 1-1/4 10.22 6.13 8.60 42NC 42NO 9-4 46-3 41A 1-1/2 9.10 6.13 7.50 1-1/2 10.22 6.13 8.60 42NC 42NO 9-4 46-3 41A 2 9.92 6.45 7.94

Phys

ical

Dim

ensi

ons

The Explosionproof housing is constructed of two (2) machined, sand-cast gray iron parts bolted together, threaded onto the bonnet assembly and rigidly cemented in place. Once assembled the housing will not rotate. NEMA 4, NEMA 5, or NEMA 7 ratings are available with this housing.

2 11.04 6.45 9.05

Phys

ical

Dim

ensi

ons

T

1-1/2” Type K-2-3T

N USA

3/4” Type KR-2-3

Rev. A

Page 51: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 1001-QKD SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/4”-1” NPT

TYPES QD & KD

2-WAY – PACKLESS DIRECT ACTING SOLENOID VALVES NORMALLY CLOSED - FULL PORT

TYPE QD: 1/8” - 1” NPT: BRONZE BODY WITH BUNA N SEAT TYPE KD: 1/8” - 1” NPT: STAINLESS STEEL BODY WITH VITON® OR TEFLON™ SEAT FOR: GENERAL SERVICE-AIR-INERT GASES-WATER-OIL-STEAM PRESSURES: 0 TO RATED MAXIMUM TEMPERATURE: -40°F. MIN TO 450°F MAX. FLUID MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 3/8" NPT FULL PORT

SERVICE RATINGS

Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for Water Service and 120 VAC Unless Otherwise Specified.

TYPE QD

GENERAL SERVICE: AIR-WATER-OIL-INERT GASES 0 to Maximum Pressure Differential 300°F. Max. Fluid Temp • Class F Coil 120, 240, 480 VAC 60 Hz, 14Watts Max

Pipe Size (NPT) 1/8-1/2 ¾ 1Orifice Diameter .63” .88” 1.00

Gases 6 psi 3 psi 2 psiWater 6 psi 2 psi 1 psi

Maximum Pressure

Differential Oil 4 psi 1 psi n/a

TYPE QD-1

HIGH TEMPERATURE SERVICE: AIR-INERT GASES-STEAM-HOT LIQUIDS 0 to Maximum Pressure Differential 450°F. Max. Fluid Temp • Class N Coil 120, 240, 480 VAC 60 Hz, 20Watts Max

Pipe Size (NPT) 1/8-1/2 ¾ 1Orifice Diameter .63” .88” 1.00

Gases 4 psi 2 psi 1 psiLiquid 4 psi 1 psi 1 psi

Maximum Pressure

Differential Steam 4 psi 2 psi 1 psi

TYPE KD

GENERAL SERVICE: AIR-WATER-OIL-INERT GASES 0 to Maximum Pressure Differential 300°F. Max. Fluid Temp • Class F Coil 120, 240, 480 VAC 60 Hz, 14Watts Max

Pipe Size (NPT) 1/8- 1/2 3/4 1Orifice Diameter .63” .50” .75” 1.00

Gases 6 psi 6 psi 3 psi 2 psiWater 6 psi 6 psi 2 psi 1 psi

Maximum Pressure

Differential Oil 4 psi 4 psi 1 psi n/a

TYPE KD-1

HIGH TEMPERATURE SERVICE: AIR-INERT GASES-STEAM-HOT LIQUIDS 0 to Maximum Pressure Differential 450°F. Max. Fluid Temp • Class N Coil 120, 240, 480 VAC 60 Hz, 20Watts Max

Pipe Size (NPT) 1/8- 1/2 3/4 1Orifice Diameter .63” .50” .75” 1.00

Gases 4 psi 4 psi 2 psi 1 psiLiquid 4 psi 4 psi 2 psi 1 psi

Maximum Pressure

Differential Steam 4 psi 4 psi 2 psi 1 psi ADD -2 EXPLOSION PROOF COIL HOUSING – NEMA 7 ADD -24 WATER TIGHT COIL HOUSING - NEMA 4 ADD -25 DUST TIGHT COIL HOUSING - NEMA 5 ADD -57 MANUAL RESET - SAFETY SHUT-OFF, NO VOLTAGE RELEASE. ADD -FL PIPE CONNECTION: -FL FLANGE

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are rated minimum 400 psi. BONNET ASSEMBLIES are Stainless Steel TUBES silver soldered or welded to BONNET and TUBE PLUG. 416 SS ARMATURE is connected to the Stainless Steel VALVE HEAD with a Stainless Steel POST.

SPECIALS: Teflon Coated Pistons & other Special Assemblies Available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory.

TERMS AND CONDITIONS OF SALE: See Back Cover of the List Price Schedule.

Page 52: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

TYPES QD, -2,-24,-25 TYPES KD, -2,-24,-25 # Part Description

NEMA Rating ⅛”- ½” 3/4” 1” ⅛”- ⅜” 1/2” 3/4“ 1”

1 Std. Bonn. Assm. 1 P403-2 P413-2 P423-2 P190 P190 P197 P204

XP Bonn. Assm. 4, 5, 7 4032XP 4132XP 4232XP 190XP 190XP 197XP 204XP

2 Bonnet O-Ring ALL 2-121 2-125 n/a n/a n/a n/a n/a

Bonnet Ring ALL n/a n/a 428 192 192 199 206

4 Lift Assm. 1 P669 P675 P677 P669 P676 P674 P677

5 Head O-Ring ALL 2-112 2-115 21-1 2-112 2-110 2-114 2-211

6 Body ALL 400-x 410 420 850-x 186 193 200 7 Armature ALL 167-1 167-1 167-1 167-1 167-1 167-1 167-18 Coil Screw ALL 9 9 9 9 9 9 9 9 Nameplate 1 44-1-1 44-1-1 44-1-1 44-1-1 44-1-1 44-1-1 44-1-1

XP Nameplate 4, 5, 7 44-3 44-3 44-3 44-3 44-3 44-3 44-3

10 Top Nip 1 115-2 115-2 115-2 115-2 115-2 115-2 115-2

XP End Plate 4, 5, 7 113 113 113 113 113 113 113

11 Coil ALL Consult Factory Or List Price Schedule 12 Coil Cover 1 89 89 89 89 89 89 89

XP Coil Cover 4, 5, 7 42NC 42NC 42NC 42NC 42NC 42NC 42NC

Bolts 4, 5, 7 9-4 9-4 9-4 9-4 9-4 9-4 9-4 Washers 4, 5, 7 46-3 46-3 46-3 46-3 46-3 46-3 46-3

13 Coil Housing 1 87 87 87 87 87 87 87

XP Coil Housing 4, 5, 7 41A 41A 41A 41A 412A 41A 41A

Cv ALL 2.9 3.6 6.8 1.2 3.0 6.0 11.0

TYPE QD KD QD-2 KD-2 Dimension ⅛”- ½” 3/4” 1” ⅛”- ⅜” 1/2” 3/4“ 1” ⅛”- ½” 3/4” 1” ⅛”- ⅜” 1/2” 3/4“ 1”

A 6.31 in 6.69 7.0 6.03 6.75 7.02 7.44 7.0 7.38 7.63 6.56 7.30 7.56 8.00 B 5.50 in 5.7 5.83 2.63 3.13 3.75 4.16 6.19 6.38 6.44 2.63 3.13 3.75 4.16 C 2.75 in 3.25 3.81 5.34 5.88 5.88 6.19 2.75 3.25 3.81 5.88 6.44 6.44 6.75

Weight 3 lbs 4 lbs 5 lbs 3 lbs 4 lbs 4 lbs 5 lbs 7 lbs 8 lbs 9 lbs 7 lbs 7 lbs 8 lbs 9 lbs

Bulletin 1001-QKD Series

PERFORMANCE, ORDERING AND INSTALLATION GUIDE ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). —————————————————————————————————————————————————————————————————————————————————————-

FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. —————————————————————————————————————————————————————————————————————————————————————

OPERATION—DIRECT ACTING FOR OPERATION FROM 0 TO RATED PRESSURE. —————————————————————————————————————————————————————————————————————————————————————

MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. —————————————————————————————————————————————————————————————————————————————————————

SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

3/4” Type QD

Page 53: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 3000-B3 SERIES

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/8”•1/4”•3/8” NPT

TYPE B3 SERIES

2-WAY - CAST BRONZE BODIES - PACKLESS

DIRECT ACTING - LEAKPROOF GENERAL PURPOSE SOLENOID VALVES

CLOSED WHEN DE-ENERGIZED

FOR: GENERAL SERVICE-AIR-WATER-LIGHT OIL-STEAM PRESSURES: 0 MINIMUM TO RATED MAXIMUM TEMPERATURE: 77°F. MAX. AMBIENT TEMP. CLASS N, 338°F MAX. FLUID TEMP. MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" • 1/4" • 3/8" NPT 3/16” STANDARD PORT NORMALLY

CLOSED

SERVICE RATINGS

Complete Pricing, Service & Electrical Ratings shown in Price Schedule . B3-21 Valves will be furnished for 0-200 PSI and 120 VAC Unless Otherwise Specified.

TYPE B3-21 AIR 0-200 psi, WATER 0-125 psi Class F: 220°F. Max. Fluid Temp., Class N: 338°F. Max. Fluid Temp. 24, 120, 240, 480, 120/240 VAC 60hz, 14 Watts Max. 6, 12, 24, 48, 115, 230 VDC, 24 Watts Max.

TYPE BH-19

STEAM 0-100 psi 338°F Maximum Steam Temperature 120, 240, 480 VAC 60hz, 15 Watts

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. BODIES are Sand Cast in 85-5-5-5 Bronze. BONNET ASSEMBLIES are 304 SS TUBES Silver Soldered into a Brass BONNET with a Brass TUBE PLUG. SEATSCREWS are Brass with PTFE O-RING. PILOT ASSEMBLIES are 416 SS ARMATURE CASE with a 303 SS PILOT POINT AND 1018 CRS ARMATURE CORE 1/8”–3/8” NPTF GLOBE STYLE BODY WITH SCREW-DOWN BONNET

See Price Schedule for "Terms and Conditions of Sale." ———————————————————————————————————————————————————

PERFORMANCE, ORDERING AND INSTALLATION GUIDE

ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS. ——————————————————————————————————————————————————————————————— FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. ——————————————————————————————————————————————————————————————— OPERATION--NO MINIMUM PRESSURE DROP IS REQUIRED FOR OPERATION. ——————————————————————————————————————————————————————————————— MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW ARROW ON VALVE BODY IS POINTING IN THE DIRECTION OF FLOW. ——————————————————————————————————————————————————————————————— SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

Page 54: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 3000-B3 SERIES 1 2 3 4 5 6 7 8 9 10 11 12 Flow Data Dimensions

Val

ve S

ize

Body

Seat

Scre

w

Bon

n. S

eal

Bonn

net

Ass

embl

y C

oil

End

plat

es

Pilo

t A

ssem

bly

Coi

l

Coi

l Can

Nam

epla

te

Coi

l Nut

Bot

tom

Nip

Top

Nip

Ori

fice

Size

Cv

Fact

or

A B C Ship Wt.

1/8 707-1 698 2-17 699 484 709 480 44-1-1 6-15 482-2 483 3/16 .70 3.94 3.38 2.0 2 lb 1/4 707-2 698 2-17 699 484 709 480 44-1-1 6-15 482-2 483 3/16 .70 3.94 3.38 2.0 2 lb 3/8 707-3 698 2-17 699 484 709

Consult the Factory

480 44-1-1 6-15 482-2 483 3/16 .70 3.94 3.38 2.0 2 lb

Page 55: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 4000-FG

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

⅛” • ¼” • ⅜” NPT

TYPES F & GSERIES

2-WAY • PACKLESS • DIRECT ACTING

GENERAL PURPOSE SOLENOID VALVES NORMALLY CLOSED OR NORMALLY OPEN • FRACTIONAL PORT

SIZES: 1/8”, 1/4”, 3/8” NPT • FRACTIONAL ORIFICE TYPE F: BRASS BODY TYPE G: 303 STAINLESS STEEL BODY FOR: GENERAL SERVICE-AIR-INERT GASES-WATER-OIL-STEAM PRESSURES: 0 TO RATED MAXIMUM TEMPERATURE: -420°F. MIN TO 450°F MAX. FLUID MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 3/8" NPT FRACTIONAL PORT

SERVICE RATINGS

Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for 150 psi Air & Water Service and 120 VAC Unless Otherwise Specified.

GENERAL SERVICE: AIR-WATER-OIL-INERT GAS 0 to Maximum Operating Pressure Differential 300°F. Max. Fluid Temperature Class F Coil 12, 24, 55, 120, 240, 480 VAC 50/60 Hz 12, 24, 32, 115, 230 VDC

MAXIMUM OPERATING PRESSURE DIFFERENTIAL TYPE ORIFICE 1/4” 7/32” 3/16” 5/32” 1/8” 3/32” 1/16”

AIR-GAS 40 50 120 175 300 550 800 WATER 30 45 60 90 140 250 500

F G

14 WATTS OIL 15 24 32 45 75 130 230 AIR-GAS 130 180 250 360 600 1000 1000 WATER 30 50 80 110 180 320 600 N

OR

MA

LLY

CLO

SED

FST GST

26 WATTS OIL 20 30 40 70 110 200 500 AIR-GAS 20 40 60 90 150 270 300 WATER 15 25 30 45 70 125 250

NO

RM

O

PEN

FR GR

14 WATTS OIL 6 10 16 23 35 60 115 HIGH TEMP. SERVICE: AIR-INERT GASES-STEAM-HOT LIQUIDS 0 to Maximum Operating Pressure Differential 450°F. Max. Fluid Temperature Class N Coil 120, 240, 480 VAC 50/60 Hz,

MAXIMUM OPERATING PRESSURE DIFFERENTIAL TYPE ORIFICE 1/4” 7/32” 3/16” 5/32” 1/8” 3/32” 1/16”

AIR-GAS 40 80 120 175 300 550 800 WATER 30 45 60 90 140 250 500

OIL 15 24 32 45 75 130 230

NORM

ALLY

CL

OSED

F-1 G-1

20 WATTS STEAM 40 80 120 200 200 200 200 AIR-GAS 20 40 60 90 150 270 300 WATER 15 25 30 45 70 125 150

OIL 6 10 16 23 35 60 150

NORM

ALLY

OP

EN FR-1

GR-1 20 WATTS STEAM 20 40 60 90 150 200 200

ADD -2 EXPLOSION PROOF COIL HOUSING – NEMA 7

ADD -3B, -3T, -3V, -3EP LEAKPROOF SEAT: -3B: BUNA, -3T: PTFE (Teflon), -3V: FLOUROCARBON (VITON), -3EP: ETHYLENE PROPYLENE

ADD -24 WATER TIGHT COIL HOUSING - NEMA 4 & NEMA 7 ADD -25 DUST TIGHT COIL HOUSING - NEMA 5 & NEMA 7 ADD -57 MANUAL RESET, SAFETY SHUT-OFF, NO VOLTAGE RELEASE.

ADD -9 SPECIAL CONSTRUCTION FOR CRYOGENIC APPLICATIONS. FLUID TEMPERATURE TO -420°F

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. 303 Stainless Steel PLUNGER TUBE is Silver Soldered or Welded into the 90° Angled, Brass, or 303 Stainless Steel BODY, providing side inlet and bottom outlet. PILOT ASSEMBLY is a 416 SS ARMATURE connected to the 303 SS POINT, that provides direct opening and closing of the valve. All COIL HOUSINGS have ½” threaded conduit connections.

Page 56: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINT

Bulletin 4000-FG

SPECIALS: Teflon Coated Pilot & other Special Assemblies Available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory.

TERMS AND CONDITIONS OF SALE: See Back Cover of the List Price Schedule

PERFORMANCE, ORDERING AND INSTALLATION GUIDE

ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). —————————————————————————————————————————————————————————————————————————————————————-

FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. —————————————————————————————————————————————————————————————————————————————————————

OPERATION—DIRECT ACTING FOR OPERATION FROM 0 TO RATED PRESSURE. —————————————————————————————————————————————————————————————————————————————————————

MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW INLET IS ON THE SIDE AND THE OUTLET IS DOWN. —————————————————————————————————————————————————————————————————————————————————————

SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

1/4” Type F

TYPES F, -2,-24,-25 TYPES G, -2,-24,-25 # Part Description

NEMA Rating 1/8” 1/4” 3/8” 1/8” 1/4” 3/8”

1

2 3

4 5

6 7 8

9

2” 1/4” 0 1.20

Body 1 P1801F P1802F P1803F P1801G P1802G P1803G XP Body 4, 5, 7 P1801FXP P1802FXP P1803FXP P1801GXP P1802GXP P1803GXP

N.O. Body 1 P1801FR P1802FR P1803FR P1801GR P1802GR P180GR N.O. XP

Body 4, 5, 7 P1801FRXP P1802FRXP P1803FRXP P1801GRXP P1802GRXP P1803GRXP

Body Nut ALL 1811Fx 1812Fx 1813Fx 1811Gx 1812Gx 1813Gx Pilot Assm. 1 P21-1 P21-1 P21-1 P21-1 P21-1 P21-1

XP Pilot Assm. 4, 5, 7 P25-1 P25-1 P25-1 P25-1 P25-1 P25-1

N.O. Pilot Assm. 1 P32R1 P32R1 P32R1 P32R1 P32R1 P32R1

N.O. XP Pilot Assm. 4, 5, 7 P32R1 P32R1 P32R1 P32R1 P32R1 P32R1

Coil ALL C o n s u l t F a c t o r y O r L i s t P r i c e S c h e d u l e Top Nip 1 115-2 115-2 115-2 115-2 115-2 115-2 XP End

Plate 4, 5, 7 113 113 113 113 113 113

N.O. Top Nip 1 115-3 115-3 115-3 115-3 115-3 115-3

Nameplate ALL 44-1x 44-1x 44-1x 44-1x 44-1x 44-1x Screw ALL 9 9 9 9 9 9

Coil Cover 1 89 89 89 89 89 89 XP Coil Cover 4, 5, 7 42NC 42NC 42NC 42NC 42NC 42NC

N.O. Coil Cover 1 89NO 89NO 89NO 89NO 89NO 89NO

N.O. XP Coil Cover 4, 5, 7 42NO 42NO 42NO 42NO 42NO 42NO

Bolts 4, 5, 7 9-4 9-4 9-4 9-4 9-4 9-4 Washers 4, 5, 7 46-3 46-3 46-3 46-3 46-3 46-3

Coil Housing 1 87 87 87 87 87 87

XP Coil Housing 4, 5, 7 41A 41A 41A 41A 41A 41A

Physical Dimensions Orifice 3/64” 1/16” 5/64” 3/32” 7/64” 1/8” 5/32” 3/16” 7/3

CV 0.05 0.08 0.12 0.18 0.26 0.30 .050 .070 1.0Shipping Weight for all Nema 1 Type F & G Valves is 2 lbs

Shipping Weight for all Nema 4, 5, & 7 Type F & G (-2) Valves is 6 lbs For Height Values of Nema 4, 5, & 7 Valves Add 0.69” For Height Values of Normally Open Valves Add 1.00”

For Height Values of Normally Open, Nema 4, 5, & 7 Valves Add 1.75”

ED IN USA Rev. A

Page 57: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 5000-GX

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

1/8” • 1/4” • 3/8” NPT

TYPE GX SERIES

2-WAY • PACKLESS • DIRECT ACTING

GENERAL PURPOSE SOLENOID VALVES NORMALLY CLOSED OR NORMALLY OPEN • FRACTIONAL PORT

SIZES: 1/8”, 1/4”, 3/8” NPT • FRACTIONAL ORIFICE MAT’L: ALL INTERNAL PARTS ARE 316 STAINLESS STEEL FOR: CORROSIVE SERVICE-AIR-INERT GASES-WATER-OIL-STEAM PRESSURES: 0 TO RATED MAXIMUM TEMPERATURE: -420°F. MIN TO 450°F MAX. FLUID MOUNTING: INSTALL IN HORIZONTAL LINE WITH COIL UPRIGHT AND ON TOP

SIZES 1/8" - 3/8" NPT FRACTIONAL PORT

SERVICE RATINGS

Pricing, Service & Electrical Ratings shown in the List Price Schedule. Valves will be furnished for 60 psi Air & Water Service and 120 VAC Unless Otherwise Specified.

CORROSIVE SERVICE: AIR-WATER-OIL-INERT GAS 0 to Maximum Operating Pressure Differential 300°F. Max. Fluid Temperature Class F Coil 12, 24, 55, 120, 240, 480 VAC 50/60 Hz 12, 24, 32, 115, 230 VDC

MAXIMUM OPERATING PRESSURE DIFFERENTIAL TYPE ORIFICE 1/4” 7/32” 3/16” 5/32” 1/8” 3/32” 1/16”

AIR-GAS 15 23 30 45 60 120 200 WATER 10 15 20 30 45 80 150

GX 26 WATTS

MAX OIL 5 8 10 15 27 40 75 AIR-GAS 40 82 120 175 300 300 300 WATER 30 46 60 90 140 250 300 N

OR

MA

LLY

CLO

SED

GXS 26 WATTS

MAX OIL 15 24 32 45 75 130 230 AIR-GAS 40 46 50 70 100 150 250 WATER 28 33 36 60 70 100 200

NO

RM

O

PEN

GRX 26 WATTS

MAX OIL 10 13 15 25 35 50 100 HIGH TEMP. SERVICE: AIR-INERT GASES-STEAM-HOT LIQUIDS 0 to Maximum Operating Pressure Differential 450°F. Max. Fluid Temperature Class N Coil 120, 240, 480 VAC 50/60 Hz,

MAXIMUM OPERATING PRESSURE DIFFERENTIAL TYPE ORIFICE 1/4” 7/32” 3/16” 5/32” 1/8” 3/32” 1/16”

AIR-GAS 15 18 20 30 45 65 120 WATER 10 13 15 20 30 45 80

OIL 5 6 7 10 15 20 40

NORM

ALLY

CL

OSED

GX-1 28 WATTS

MAX STEAM 15 18 20 30 45 65 120

AIR-GAS 28 32 35 50 70 100 150 WATER 20 23 25 40 50 70 150

OIL 7 8 10 16 25 35 70

NORM

ALLY

OP

EN GRX-1

28 WATTS MAX

STEAM 28 32 35 50 70 100 150 ADD -2 EXPLOSION PROOF COIL HOUSING – NEMA 7

ADD -3B, -3T, -3V, -3EP LEAKPROOF SEAT: -3B: BUNA, -3T: PTFE (Teflon), -3V: FLOUROCARBON (VITON), -3EP: ETHYLENE PROPYLENE

ADD -24 WATER TIGHT COIL HOUSING - NEMA 4 & NEMA 7 ADD -25 DUST TIGHT COIL HOUSING - NEMA 5 & NEMA 7 ADD -57 MANUAL RESET, SAFETY SHUT-OFF, NO VOLTAGE RELEASE.

ADD -9 SPECIAL CONSTRUCTION FOR CRYOGENIC APPLICATIONS. FLUID TEMPERATURE TO -420°F

CONSTRUCTION: CLASS F & N COILS are Waterproof, Fungusproof, Molded of Filled Polyester with 18" Leads. 316 Stainless Steel PLUNGER TUBE is Welded into the 90° Angled 316 Stainless Steel BODY, providing side inlet and bottom outlet. The PILOT has a 316 SS JACKET Welded around a carbon steel CORE, that provides direct opening and closing of the valve. All COIL HOUSINGS have ½” threaded conduit connections.

Page 58: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

TYPES G, -2,-24,-25 # Part Description

NEMA Rating 1/8” 1/4” 3/8”

1 Body 1 P1801GX P1802GX P1803GX XP Body 4, 5, 7 P1801GXXP P1802GXXP P1803GXXP N.O. Body 1 P1801GRX P1802GRX P180GRX

N.O. XP Body 4, 5, 7 P1801GRXXP P1802GRXXP P1803GRXXP

2 Body Nut ALL 1811GXx 1812GXx 1813GXx 3 Pilot Assm. 1 P2421 P2421 P2421

XP Pilot Assm. 4, 5, 7 P2421 P2421 P2421

N.O. Pilot Assm. 1 P242R4 P242R4 P242R4

N.O. XP Pilot Assm. 4, 5, 7 P242R4 P242R4 P242R4

4 Coil ALL 5 Top Nip 1 115-2 115-2 115-2 XP End Plate 4, 5, 7 113 113 113

N.O. Top Nip 1 115-3 115-3 115-3

6 Nameplate ALL 44-1x 44-1x 44-1x 7 Screw ALL 9 9 9 8 Coil Cover 1 89 89 89

XP Coil Cover 4, 5, 7 42NC 42NC 42NC

N.O. Coil Cover 1 89NO 89NO 89NO

N.O. XP Coil Cover 4, 5, 7 42NO 42NO 42NO

Bolts 4, 5, 7 9-4 9-4 9-4 Washers 4, 5, 7 46-3 46-3 46-3 9 Coil Housing 1 87 87 87

XP Coil Housing 4, 5, 7 41A 41A 41A

Physical Dimensions Orifice 3/64” 1/16” 5/64” 3/32” 7/64” 1/8” 5/32” 3/16” 7/32” 1/4”

CV 0.05 0.08 0.12 0.18 0.26 0.30 .050 .070 1.00 1.20Shipping Weight for all Nema 1 Type GX Valves is 2 lbs

Shipping Weight for all Nema 4, 5, & 7 Type GX (-2) Valves is 6 lbs For Height Values of Nema 4, 5, & 7 Valves Add 0.69” For Height Values of Normally Open Valves Add 1.00”

For Height Values of Normally Open, Nema 4, 5, & 7 Valves Add 1.75”

Bulletin 5000-GX

SPECIALS: Teflon Coated Pilot & other Special Assemblies Available. Non-Standard Coils are Available with Voltage, Wattage, and Lead Wire Length to your specifications. Consult Factory.

TERMS AND CONDITIONS OF SALE: See Back Cover of the List Price Schedule

PERFORMANCE, ORDERING AND INSTALLATION GUIDE

ORDERING DATA--SPECIFY PIPE SIZE, TYPE, FLUID, OPERATING PRESSURE, TEMPERATURE RANGE, ELECTRICAL SPECIFICATIONS, BACK PRESSURE (IF ANY). —————————————————————————————————————————————————————————————————————————————————————-

FLOW CHARACTERISTICS--SEE FLOW CURVES IN BULLETIN 5-FL, OR Cv FACTORS LISTED BELOW AND IN BULLETIN CP-1. —————————————————————————————————————————————————————————————————————————————————————

OPERATION—DIRECT ACTING FOR OPERATION FROM 0 TO RATED PRESSURE. —————————————————————————————————————————————————————————————————————————————————————

MOUNTING--MOUNT IN HORIZONTAL LINE WITH COIL VERTICAL AND ON TOP. INSTALL 40 MESH STRAINER (NOT LARGER) AHEAD OF VALVE. CHECK FOR PROPER COIL VOLTAGE. MAKE SURE THAT THE FLOW INLET IS ON THE SIDE AND THE OUTLET IS DOWN. —————————————————————————————————————————————————————————————————————————————————————

SERVICING--SOLENOID VALVES SHOULD BE FREQUENTLY CHECKED FOR OPERATION, CLEANLINESS, & INTERNAL WEAR - REPAIR KITS ARE FACTORY AVAILABLE --GIVE SIZE, TYPE, SERIAL NUMBER OR OPERATING DATA (VOLTAGE, PRESSURE, ETC.)

1/4” Type GX

Page 59: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

Solenoid Valves J. D. Gould Company, Inc. • P. O. Box 18128 • Indianapolis, IN 46218-0128

phone: (800) 63-GOULD • fax: (317) 547-5234 website: www.gouldvalve.com • email: [email protected]

Page 60: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

This Page Intentionally left blank

Page 61: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. B

BULLETIN 3-OP

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

GENERAL INSTALLATION &

OPERATING INSTRUCTIONS

DESCRIPTION AND OPERATION: TYPES A, B, D, K, M & Q are packless, internal PISTON, PILOT OPERATED solenoid valves and require a 5 PSI MINIMUM OPERATING PRESSURE DIFFERENTIAL. When the coil is energized, it lifts the pilot valve off the seat screw, opening the pilot orifice through the center of the piston to the outlet side of the valve. This relieves the pressure from the top of the piston ring and pressure under the piston ring forces the piston up to open the main valve orifice. When the coil is de-energized, the pilot valve returns to close the pilot orifice and pressure across the piston ring is equalized through a timing orifice in the side of the piston or in the valve body. The piston spring returns the piston to close the main valve orifice. TYPES F, G, GX, B3, AD, QD, & KD are DIRECT ACTING solenoid valves and do not require a minimum operating differential pressure. When the coil is energized, it lifts the solenoid plunger, which is mechanically connected to the valve seat and lifts it to open the main valve orifice. When the coil is de-energized, gravity and flow return the valve seat to close the main valve orifice. TYPES J, & KJ are ZERO DIFFERENTIAL, internal PISTON, PILOT OPERATED solenoid valves. At low pressure, the coil opens the valve much like a direct acting valve, but at higher pressure it functions like a pilot operated valve. NORMALLY CLOSED valves OPEN when the coil is energized. NORMALLY OPEN valves (indicated by the letter R after the basic type designation) CLOSE when the coil is energized. The PILOT VALVE ONLY is normally open on piston pilot operated solenoid valves. The PISTON opens only with application of PRESSURE. ALL Standard valves are supplied with CONTINUOUS DUTY COILS of the proper class of insulation for the service indicated on the nameplate. The COIL TEMPERATURE after being energized for extended periods, although uncomfortably warm to touch, is a safe operating temperature. Smoke or burning odor indicates excessive coil temperature. INSTALLATION: Install in HORIZONTAL pipe with the COIL ASSEMBLY on TOP AND VERTICAL with FLOW ARROW or IN AND OUT markings in the proper direction. ALL PIPING should be blown clear before installation and a STRAINER should be installed ahead of the valve, STEAM LINES should be properly TRAPPED at the valve inlet. PIPE DOPE is NOT recommended, but if used should not be applied to the VALVE BODY. Apply sparingly to the pipe threads only. J. D. Gould Company recommends Teflon™ tape for all connections. PIPING should be properly aligned and supported to avoid strain on the valve body. The VALVE BODY should not be held in a VISE except across the pipe ends. Use a PIPE VISE or WRENCH on the pipe and a WRENCH on the HEX PIPE ENDS. DO NOT use the COIL ASSEMBLY for a LEVER to tighten piping. WIRING: ALL COIL HOUSINGS have 1/2" THREADED CONDUIT connectors. Check the NAMEPLATE for PROPER VOLTAGE and connect the COIL LEAD WIRES to line voltage in accordance with applicable ELECTRICAL CODES. The LEAD WIRES are not polar, and either may be connected to pos (+) or neg (-). The GREEN wire (when equipped) should be connected to ground. Standard NEMA 1 enclosures, (except Type B3) do not require a separate wiring JUNCTION BOX. Wiring can be run through the conduit connection in the COIL HOUSING and connected to the COIL LEADS inside COIL COVER. DUAL VOLTAGE COILS must be wired in accordance with the DIAGRAM shown on the coil housing. Standard COIL HOUSING may be rotated as required to facilitate wiring. EXPLOSION PROOF HOUSINGS are FIXED and CANNOT be ROTATED except on valves equipped with UNION BONNETS. TORQUE for EXPLOSION PROOF HOUSING BOLTS is 15 ft•lbs.

Page 62: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. B

Bulletin 3-OP ADJUSTMENT TYPES B & D ONLY: Adjustments are pre-set at the factory to meet average conditions (or to your specifications); however, individual requirements in the field may necessitate further adjustment. To increase opening speed or decrease closing speed, turn stem at base marked ADJ. clockwise (IN). To decrease opening speed or increase closing speed, turn stem counterclockwise (OUT). On slow opening valves or high-pressure (above 300 PSIG) valves, this adjustment, if opened too far counter-clockwise, will create a situation in which the valve will fail to open. To correct this, close the ADJ. stem (clockwise) with pressure on and solenoid energized until valve opens. FLOW CONTROL (Type D with NEMA 1 Coil Enclosure ONLY) Valves are set at factory for full flow unless otherwise specified. To adjust flow rate thru valve, relieve line pressure ahead of valve and loosen nameplate screw. It is not necessary to disconnect wiring or remove coil. Turn bonnet (clockwise) to reduce flow. No wrench is needed if pressure is off system. With bonnet down as far as possible, approximately 25% full flow is obtained. To obtain full flow, back the bonnet off (counter-clockwise) 3 turns for ¾”-1" valves; 4½ turns for 1¼”-1½" valves; or 6 turns for 2" valves. At this position, arrows (or stamped “½” on 1¼”-1½ valve) on body and bonnet are in line and bottom of bonnet is just above full flow line on body. Do not open bonnet above this line. After proper adjustment is made, tighten nameplate screw. (Note: some older valves may have a set-screw to lock the bonnet in place. This must be loosened before adjustment.) MAINTENANCE: Close the supply SHUT OFF VALVE and ENERGIZE the SOLENOID VALVE to de-pressurize the inlet supply line. DISCONNECT ELECTRICAL POWER before removing the COIL ASSEMBLY. The COIL will overheat and burn out if left ENERGIZED without the entire SOLENOID ASSEMBLY in place. Since OCCASIONAL INSPECTION AND CLEANING is desirable, be sure to add the valves to your scheduled maintenance program. Flowing media and cycle rate will determine the desired interval between inspections. Removing the BONNET exposes the internal parts of the valve. It is not necessary to remove the VALVE BODY from the line for inspection or repairs. Valve parts may be cleaned in commercial products such as Lime-Away® or CLR™ to remove mineral deposits. Be sure any cleaning solution is compatible with BOTH the metallic and non-metallic (seats & seals) components. Parts should be rinsed thoroughly in clean running water before re-assembly. BOLT TORQUE for valves with bolt-on bonnets is as follows: 1¼” & 1½” Type K & KX 60 ft•lb 2” Type K & KX 70 ft•lb 4” Type E & EF 75 ft•lb Refer to INDIVIDUAL BULLETINS for ASSEMBLY DRAWINGS AND PARTS LIST. INSPECTION CHECK LIST: VOLTAGE must be within +10% to -15% of the nominal voltage indicated on the nameplate. To check the SOLENOID OPERATION energize and de-energize the solenoid several times. An audible CLICK indicates the solenoid is working properly. If no click is heard, check SUPPLY VOLTAGE. If voltage supply at the coil is proper, check the COIL for open or shorted turns with an OHMMETER. The pilot valve PLUNGER must be free to move in the BONNET PILOT TUBE. The TUBE must be straight and perpendicular to the BONNET FACE and not kinked, bent or deformed. The PISTON ASSEMBLY should move freely in the cylinder bore with the application very little force. The PISTON RING should be free in the ring groove and the EXPANDER under the piston ring should hold the piston ring in contact with the cylinder bore. The END GAP in the step cut of the piston ring should never be less than .020". The SEAT SCREW pilot orifice should be round and free from nicks, burrs or erosion. The DISC and main orifice SEAT should not be worn or chipped. The cylinder bore in the valve BODY should be round, smooth and free from wear, nicks or gouges. REPLACEMENT PARTS: After inspection, replace all worn or damaged parts. REPAIR KITS are available from stock or from local Sales Representatives. Refer to individual SOLENOID VALVE BULLETINS for description and part numbers. Some individual REPAIR PARTS are also available for special repair requirements.

Page 63: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

BULLETIN 5-FL

4707 Massachusetts Ave. - P.O. Box 18128Indianapolis, Indiana 46218-0128

Ph: 1-800-63 GOULD Fx: (317) 547-5234 Web: http://www.gouldvalve.com

E-mail: [email protected]

SOLENOID VALVES

CAPACITY CHARTS

See Individual Bulletins for CV Factors

WATER CAPACITY FOR FRACTIONAL ORIFICES

Page 64: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA Rev. A

Bulletin 5-FL Capacity Charts Page 2

AIR AND GAS CAPACITY CHART FOR GOULD VALVES

To Determine Capacity: 1> Locate differential pressure on scale at

right of chart. 2> From this point cross horizontally to

the proper inlet pressure curve. 3> Move vertically from this intersection

to the horizontal line indicating valve size.

4> The diagonal line at this intersection indicates maximum valve capacity.

To Determine Valve Size: 1> Find the intersection of the differential

pressure line and inlet pressure curve. 2> Move vertically to the diagonal line of

desired capacity. 3> The horizontal line at this intersection

indicates proper valve size.

To correct capacity for gases with specific gravity other than 1.0, multiply by the

following factors.

Specific Gravity Factor .6 1.29 .7 1.20 .8 1.12 .9 1.05 1.0 1.00 1.1 0.95 1.2 0.91 1.3 0.88 1.4 0.85 1.5 0.82

Page 65: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PR

C

D

Bulletin 5-FL Capacity Charts Page 3

LIQUID CAPACITY FOR GOULD VALVES

o Determine Capacity of Valve: > Locate differential pressure at bottom of chart. > Move vertically to horizontal line indicating valve size. > Follow diagonal line from this point to specific gravity lines at the top or right. > Capacity is shown at the intersection of the specific gravity and diagonal lines.

o Determine Valve Size for Given Capacity: > Locate intersection of desired capacity and specific gravity at the top or right. > Follow diagonal line from this intersection to vertical differential pressure line. > The horizontal line at this point indicates valve size.

N

T

Fow

ONVERSION TABLE

eg. API

Sp. Gr. 60º/60ºF

10 1.0000 12 0.9861 14 0.9725 16 0.9593 18 0.9465 20 0.9340 22 0.9218 24 0.9100 26 0.8984 28 0.8872 30 0.8762 32 0.8655 34 0.8550 36 0.8448 38 0.8348 40 0.8250 42 0.8156 44 0.8062 46 0.7972 48 0.7882 50 0.7796 52 0.7710 54 0.7628 56 0.7547 58 0.7467 60 0.7389 62 0.7313 64 0.7237 66 0.7165 68 0.7093 70 0.7022 72 0.6953 74 0.6886 76 0.6819 78 0.6754 80 0.6690 82 0.6628 84 0.6566 86 0.6506 88 0.6446 90 0.6388 92 0.6330 94 0.6275 96 0.6220 98 0.6165

100 0.6112

T1234 T123

INTED IN USA 29-Mar-01

otes: he diagonal lines indicating capacity change direction 90° at top of chart at 0.5 specific gravity. r hydraulic oil (viscosity 105 SSU @ 100°F) multiply discharge by 0.6 to obtain corrected capacity

hile using Specific gravity of 1.0.

Page 66: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

PRINTED IN USA 29-Mar-01

Bulletin 5-FL Capacity Charts Page 4

STEAM CAPACITY CHART FOR GOULD VALVES To Determine Capacity: 1> Locate differential pressure on

scale at right of chart. 2> From this point cross

horizontally to the proper inlet pressure curve.

3> Move vertically from this intersection to the horizontal line indicating valve size.

4> The diagonal line at this intersection indicates maximum valve capacity.

To Determine Valve Size: 1> Find the intersection of the

differential pressure line and inlet pressure curve.

2> Move vertically to the diagonal line of desired capacity.

3> The horizontal line at this intersection indicates proper valve size.

Page 67: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218

PRINTED IN USA

Slide Rule Instructions

SOLENOID VALVES

4 7 0 7 M AS S AC H U S E T T S AV E . P . O . B O X 1 8 1 2 8

I N D I AN AP O L I S , I N D I AN A 4 6 2 1 8 - 0 1 2 8 P H O N E : 3 1 7 5 4 7 - 5 2 8 9

SLIDE RULE INSTRUCTIONS ( B Y E X A M P L E )

The slide rule utilizes the Flow Coefficient Value (Cv) Method for calculating flow. Cv factors for all sizes and types of Gould Solenoid Valves are shown in our List Price Schedule, and all our individual valve bulletins. DEFINITIONS:

SP. GR. SPECIFIC GRAVITY: WATER OR AIR - 1.0 PRESSURE DROP INLET MINUS OUTLET PRESSURE (PSI) PSIA LBS /SQ IN. ABSOLUTE (GAGE + 14.7 PSI) P1 INLET PRESSURE IN PSIA P2 OUTLET PRESSURE IN PSIA

*******

EXAMPLE: LIQUID SERVICE BY VOLUME

REQUIRED: Valve Size, Cv for a Flow Rate of 20 GPM water at 10 PSI maximum Pressure Drop.

SET: 10 on Pressure Drop By Volume scale opposite 1.0 on SP. GR. scale.

READ: 6.3 on Cv scale opposite 20 (GPM) on Flow scale.

SELECT: ¾” Type M Gould Solenoid Valve with a Cv Factor of 6.8. NOTE: Piston Pilot Operated Solenoid Valves require a 5 PSI minimum pressure Drop (Differential).

RESET: 20 (GPM) on Flow scale opposite 6.8 on Cv scale.

READ: 8.5 on Pressure Drop scale opposite 1.0 on SP. GR. scale. The ¾” Type M valve will flow 20 GPM with an 8.5 PSI Pressure Drop.

******* REQUIRED: Pressure Drop through a 1 ½” Type M valve, Cv of 26 with a Flow Rate of 200 GPM

of a fluid with a SP. GR. of 1.0.

SET: 200 (GPM) on the Flow scale opposite 26 on the Cv scale.

READ: 60 PSI on Pressure Drop scale opposite 1.0 on SP. GR. scale.

******* EXAMPLE: LIQUID SERVICE BY WEIGHT

REQUIRED: Flow Rate of Trichloroethylene with SP. GR. of 1.456 in LBS/HR using a 2” Type K valve, Cv of 45, with a Pressure Drop of 50 PSI.

SET: 50 PSI on Pressure Drop By Weight scale opposite 1.456 (1.5) on SP. GR. Scale.

READ: 195,000 (195 X 1000) LBS/HR on Flow scale opposite 45 on Cv scale.

Page 68: Application Information - Famco Inc.famco.ca/wp-content/uploads/2013/07/JD-Gould.pdf · INDIANAPOLIS, INDIANA 46218 PRINTED IN USA VALVE USES BY INDUSTRY SOLENOID ... Various Assembly

J. D. GOULD COMPANY 4707 MASSACHUSETTS AVE. INDIANAPOLIS, INDIANA 46218

PRINTED IN USA

Slide Rule Instructions

SOLENOID VALVES

4 7 0 7 M AS S AC H U S E T T S AV E . P . O . B O X 1 8 1 2 8

I N D I AN AP O L I S , I N D I AN A 4 6 2 1 8 - 0 1 2 8 P H O N E : 3 1 7 5 4 7 - 5 2 8 9

EXAMPLE: GAS SERVICE BY VOLUME

REQUIRED: Valve Size, Cv for a Flow Rate of 15,000 Standard Cubic Feet Per Hour (SCFH) of Air, SP. GR. of 1.0, Inlet Pressure of 100 PSI and Outlet Pressure of 42 PSI.

CALCULATE: Pressure Drop = 100 PSI - 42 PSI = 58 PSI P1 = 100 PSI + 14.7 PSI = 114.7 PSIA NOTE: Pressure Drop Exceeds 1/2 Inlet PSIA

SET: Inlet PSIA of 114.7 on Factor “G” scale opposite 1.0 on SP. GR. scale

READ: 3.6 on Cv scale opposite 15 (15,000 SCFH) on Flow scale.

SELECT: ½” Type M-3V with a Cv of 3.6 (see the List Price Schedule).

******* REQUIRED: Valve Size, Cv for Flow Rate of 3200 SCFH of Helium SP. GR. of 0.138, Inlet

Pressure of 150 PSI and Outlet Pressure of 120 PSI.

CALCULATE: Pressure Drop = 150 PSI - 120 PSI = 30 PSI P1 + P2 = 150 PSI + 14.7 PSI + 120 PSI + 14.7 PSI = 279.4 PSIA NOTE: Pressure Drop is less than ½ Inlet PSIA.

SET: 30 on Pressure Drop scale opposite 300 on the P1 + P2 scale.

READ: 110 on Factor “G” scale opposite arrow on SP. GR. scale.

RESET: 110 on Factor “G” scale opposite 0.138 on SP. GR. scale.

READ: 0.3 Cv opposite 3.2 (3200 SCFH) on Flow scale.

SELECT: ¼” Type F valve with a 1/8” Orifice (see List Price Schedule).

******* EXAMPLE: STEAM SERVICE BY WEIGHT

REQUIRED: Valve Size, Cv for a Flow Rate of 6500 LBS/HR Saturated Steam, Inlet Pressure of 150 PSI and Outlet Pressure of 100 PSI.

CALCULATE: Pressure Drop = 150 PSI – 100 PSI = 50 PSI P1 + P2 = 150 PSI + 14.7 PSI + 100 PSI + 14.7 PSI = 279.4 PSIA NOTE: Pressure Drop is less than 1/2 Inlet PSIA.

SET: 50 on Pressure Drop scale opposite 280 on P1 + P2 scale. NO RESETTING for Steam Superheat is necessary for Saturated Steam.

READ: 26 Cv opposite 6.5 (6500 LBS/HR) on Flow scale,

SELECT: 1 ½” Type Q-1 with a Cv Factor of 26 (see List Price Schedule).