Upload
ngodien
View
217
Download
0
Embed Size (px)
Citation preview
1 | P a g e
Appliance Tagging Services Pty Ltd
SAFE WORK METHOD STATEMENTS
Be warned. Any reproduction of this safety management system or associated documents without the express permission of the company and the National Electrical and Communications Association may immediately initiate legal action against that person or organization.
Company Name Appliance Tagging Services Pty Ltd
Issue Date 02/09/2014
Revision Date 01/09/2015
Revision Number 1
Prepared by Sarah Allen
Project Appliance Test and Tag
Project Manager Shankary Mahendran
Project Manager Phone 1300 287 669
Client TBA
Site Address TBA
Distribution ATS Technicians, TBA Staff
2 | P a g e
DOCUMENT CONTROL
Issue Revision Date Description Originator Approved
1 1 02/09/2014 Appliance Test and Tag Sarah Allen
DOCUMENT APPROVAL AND ISSUE
Copy Number
Issued To Date
Approved by Date
Position
Appliance Tagging Services Pty Ltd Safe Work Method Statements
3 | P a g e
SAFE WORK METHOD STATEMENT - INDEX
SWMS No. Task Title Pages Rev
001 Using Portable Ladders 3
002 Manual Handling 4
003 Working at Heights 4
004 Working near Switchboards – RCD Testing 2
005 Working near Switchboards – Exit and Emergency Lighting Testing 2
006 Testing Portable Electrical Appliances 4
007 Visual Only Risk Assessment of Portable Electrical Appliances and Leads – Equipment not Shut Down
4
008 Vehicle Hazards and Security 2
009 Microwave Leakage Testing 2
010 Level 1 and Level 2 Inspection of Portable Fire Extinguishers 3
011 Level 1 and Level 2 Inspection of Service Fire Hose Reels 3
012 Monthly and Annual Inspection of Fire Hydrants 3
013 Working Outside of Normal Business Hours 2
014 Working on Switchboards – RCD Testing by Licensed Electrician 3
Acknowledgement
I have been consulted on the implementation of the Safe Work Method Statements (SWMS) listed above,
and I have read and understood the SWMS’s and agree to work to the requirements of these Safe Work
Method Statements.
Name Signature Date
Appliance Tagging Services Pty Ltd Safe Work Method Statements
4 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: SWMS No. Page 1 of 2
Person responsible for ensuring compliance with this SWMS:
<Person responsible for SWMS Compliance> Contact Number: <Phone Number> Date: <Date> Revision: <#>
Project / Client: Location:
Work Method Steps / Task Description Hazards Identified Risk Level Recommended Actions / Controls for Prevention Residual Risk Person
Responsible
Break the job down into steps.
Follow the six stages identified
1. make it safe - site inspection, safety/skills training; licences; permits; job
analysis/planning; lockout/tagout.
2. get it ready - safety signage; barricades; ventilation; lighting; materials;
equipment; tools; access ways, etc.
3. do this first - safety test; initial task/preparatory works.
4. do this next - the processes and tasks in a logical sequence.
5. make it secure - inspect; test; secure works; lockout/tagout; replace/lock
covers; close off access; etc.
6. clean up/put away - surplus materials, hazardous materials/packaging;
waste recycling; equipment/tools, etc.
Each step should accomplish some major task and be in a logical
sequence
NNumber each step to facilitate cross-referencing
Identify the hazards and
risks associated with each
step.
Hazards are unsafe
conditions and unsafe
acts.
A Hazard may
be either intrinsic or
inherent, actually existing
or potential.
Examine each to find
possibilities that could
lead to an accident.
The risk may vary
according to
circumstances.
Class 1 or
High
Class 2 or
Medium
Class 3 or
Low
Specify what practices/procedures will be
implemented and what action will be taken to
eliminate or minimise the hazards, and/or
potential severity factors, and the risk of
serious injury/damage.
Include the measures to be taken to ensure
continuity and effectiveness of the proposed
controls so they can be and will be maintained.
The Residual Risk is
the risk level after
the control
measure has been
implemeted.
Control measures
must be adequate
to make the
Residual Risk Class 3
or Low.
Identifies the
person or persons
responsible for
ensuruiing the
corrective action
is complied with.
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
5 | P a g e
SWMS Title: SWMS No. Page 2 of 2
Personnel Qualifications and Experience Required
Personnel Duties and Responsibilities Training Required to Complete Work
Engineering Details / Certificates / WorkCover Approvals / Australian
Standards
Referenced - Codes of Practice / Regulations / Legislation
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8
Appliance Tagging Services Pty Ltd Safe Work Method Statements
6 | P a g e
Hazard Identification & Risk Assessment
Procedure
A Safe Work Method Statement (SWMS) is the process of identifying potential hazards, assessing their risk and
recording how to eliminate, or minimize, the risk to worker safety (controls). The Safe Work Method Statement
(SWMS) is similar to a Job Safety Analysis (JSA) that was used to identify hazards and control risks previously.
To help find all potential hazards the job will be broken down into activities which follow the sequence of
construction. These activities are detailed in a Safe Work Method Statement (SWMS), which is a list of job
procedures, and other work related practices provided to the Principal Contractor. The SWMS details how the Scope
of Work will be carried out.
For each of the work activities and associated job steps identified in the Safe Work Method Statement provided ATS
Pty Ltd will identify potential hazards.
Generic task specific Safe Work Method Statements are developed by industry for particular tasks specific to the
electrical and communications industry. These SWMS assist in the development of a site specific / task specific SWMS
for the particular task at a particular site at a particular time. An index of the available developed SWMS follows and
copies of these SWMS can be found in the <Replace this space with the name of your company.> Site Safety Plan.
A generic (not specific to any site) Safe Work Method Statement will be submitted at tender. Broadly defined job
steps will be used and general hazards identified. The SWMS will demonstrate that ATS Pty Ltd have identified the
risks (particularly the High and medium risks) involved in the work and typical controls used. This SWMS will be
provided for the purpose of tender evaluation.
Prior to commencement of work on site the generic SWMS submitted at tender will be reviewed. Where additional
hazards are identified or job steps and/or site conditions vary from those planned, the SWMS will be reviewed and
updated to reflect the way the job will actually be done on the specific site and how safety will be controlled – a site
specific SWMS.
The SWMS Form details the person responsible for ensuring compliance with the SWMS and requires sign off by the
persons involved in doing the task. It details the hazards identified and the control measures to be implemented. The
completed SWMS Form provides a record to demonstrate compliance to Occupational Health and Safety Legislation.
Evaluation of the SWMS The SWMS will be evaluated on how well High and Medium hazards have been identified for the work activity to be undertaken and whether the suggested controls, wherever possible, eliminate the potential hazard or minimise the risk of injury.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
7 | P a g e
Controls should be as high as practical in the “Best to Worst” guide shown below.
1. Remove the hazard completely e.g. remove risk of electrocution by using compressed air driven tools.
2. Separate people from the hazard e.g. guards on power tools, e.g. use effective barriers and edge protection, e.g. enclose noisy machinery.
3. Use an engineered control e.g. use Earth leakage device (safety switch) on electrical power source. e.g. use a machine to lift heavy objects. e.g. use scaffolding rather than ladders to reduce risk of falls.
4. Change work practices e.g. training in lifting techniques. e.g. tagging procedures.
5. Provide personal protection (PPE) e.g. hearing protection, eye protection etc. Note: PPE should be the last
barrier chosen to protect people.
Selection and Use
In consultation with the workers performing the task, the generic SWMS will be reviewed and a Site Specific
SWMS will be developed where additional task steps or hazards are identified on site.
The completed Site Specific SWMS will be signed by the ATS Pty Ltd person who is responsible for ensuring
compliance with the Site Specific SWMS.
Employees will review the Site Specific SWMS and sign the SWMS Form as an acknowledgement that they
understand and are willing to implement the controls required to carry out the work safely.
Where required the Site Specific SWMS will be reviewed and signed by the appropriate <Clients Name>
representative on the project.
Work will not proceed until the above criteria is achieved.
Risk Levels Consequence
Pro
bab
ility
A B C D E PROBABILITY CONSEQUENCE
1 1 1 1 2 2 1 Almost Certain A Catastrophic
2 1 1 2 2 2 2 Likely B Major
3 1 2 2 3 3 3 Occasional C Moderate
4 2 2 2 3 3 4 Unlkely D Minor
5 2 3 3 3 3 5 Rare E Insignificant
Class 1 High Risk
Class 2 Medium Risk
Class 3 Low Risk
Best
Control
Worst
Control
Appliance Tagging Services Pty Ltd Safe Work Method Statements
8 | P a g e
SAF-003: JOB SAFETY ANALYSIS (JSA) WORKSHEET
JSA No: Workplace: Sub-Contractor:
Process:
Analysis By: Reviewed By:
/ / Approved By:
/ /
Process Steps Potential Hazards Risk Level Hazard Control Measures
List the steps required to perform the task in the sequence they are carried out
List the potential hazards that could cause injury when the task is performed
Likelihood & severity
For each hazard identified, list the control measures required to eliminate or minimise the risk of injury
Appliance Tagging Services Pty Ltd Safe Work Method Statements
9 | P a g e
Process Steps Potential Hazards Risk Level Hazard Control Measures
List the steps required to perform the task in the sequence they are carried out
List the potential hazards that could cause injury when the task is performed
Likelihood & severity
For each hazard identified, list the control measures required to eliminate or minimise the risk of injury
Appliance Tagging Services Pty Ltd Safe Work Method Statements
10 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: USING PORTABLE LADDERS SWMS NO. 001 Page 1 of 3
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual Risk Person Responsible
1.Select appropriate ladder with regard to compliance
with the relevant part of AS1892 and the work to be
done
Electric shock 1 Metal or wire reinforced ladders shall not be used for any
work where there may be a live electrical installation.
3 Worker
2.Inspect the ladder for condition Falling 2 Inspect ladders. Do not use damaged ladders. 3 Worker
3.Handling extension ladders. Manual Handling
Ladder falling on person.
Fingers caught in ladder
rungs while extending ladder
2
2
2
Two man carry of large extension ladders.
Two person lift to stand ladder up – one person footing ladder.
Ladder tied into position or footed until top of ladder can be
secured.
Fingers away from ladder rungs while extending.
3
3
3
Worker
Worker
Worker
4.Position ladder to ensure stability Falling
Ladder slipping into
dangerous location
2 Position ladders a minimum of 1 metre from edges of slabs or
floors. Increase this distance as working heights increase.
Straight or extension ladders to be secured at top and bottom.
Ladders need to extend 1 metre above landing level and to be
long enough to work at least 1 metre from the top of the
ladder.
Angle of ladder should be nominally 1 in 4
Always face the ladder when ascending or descending a ladder
keep two hands and one foot on the ladder.
Fall protection to be used when working above 2.0 m
3 Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
11 | P a g e
SWMS Title: USING PORTABLE LADDERS SWMS NO. 001 Page 2 of 3
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
5.Using the ladder. Falling
Dropping tools on
others.
2
2
Hoist tools and equipment with rope – keep both hands free for
climbing.
Barricade area to prevent persons from walking under ladder while in
use.
Do not overload pockets or tool belts with items that may fall out.
Ensure footwear is appropriate and free from mud or oil.
3
3
Worker
Worker
6.Step Ladders Falling on others 2 Erect stepladders on even and level surface.
Tie ladder to permanent structure if possible.
Clear people form the immediate area if possible.
3 Worker
7.Working on step ladders Falling 2 Employees instructed to not use top steps.
Not to straddle the step ladder
Not to reach out too far
Not to place tools and equipment on the top step unless designed for
the task
3 Worker
8.Removal of ladder Falling 3 Leave base of ladder tied until the top is untied 3 Worker
Additional items identified on site
Supervisor/
Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
12 | P a g e
SWMS Title: USING PORTABLE LADDERS SWMS NO. 001 Page 3 of 3
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Tradesman and others trained and competent in the use of
portable ladders and working around electricity
Supervisor to carry out daily inspections of work site for hazards. Supervisor to be trained in hazard identification, risk assessment
and control eg, SWMS
Industry and Site induction All personnel to maintain tidy work area on site at all times. Personal
Protective Equipment (PPE) to be worn at all times on site.
Supervisor to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task
No previous particular experience required
Barricading to be used as appropriate to protect others from working below
elevated work.
On the job skills training to be conducted by Supervisor to
personnel.
Engineering Details / Certificates /
WorkCover Approvals / Australian
Standards
Referenced – Codes of Practice / Regulations / Legislation
Ladders to be in accordance with
Australian Standard AS 1892
All PPE used to meet & be maintained to
Australian Standards
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe Electrical
Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act Regulations 1947,
Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997, Electrical
Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
All States: Code of Practice - Compliance Code Prevention of Falls. Code of Practice Manual Handling
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Ladders complying with the relevant part of Australian Standard AS 1892. Ladders to be checked daily. Hard Hat, Ear protection, Eye protection, Safety Vest
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
13 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: MANUAL HANDLING SWMS NO. 002 Page 1 of 4
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
Risk Assessment N/A N/A Consider the task at hand and assess the risk factors which are likely to cause manual handling injuries, taking into account the following factors
–
Actions and movements used;
Layout/condition of work environment;
Posture of the body whilst working;
Duration and frequency of the task;
Weight and position of the object and its intended final location;
Nature of the object;
Work organisation;
Age, skill and experience of the worker;
Force applied.
N/A Supervisor/
Worker
Risk Control N/A N/A When a manual handling risk has been identified, take steps to control it
by –
Redesigning the task to remove or minimise the risk;
If redesign is not possible, use mechanical aids (where practicable) to
assist in the task and remove the manual handling risk;
If neither is possible, then provide particular training/ education to
the worker(s) to control the risk.
N/A Supervisor/
Worker
Preparation: Assess size, shape, condition and weight of load(s).
Slips, trips and falls. 2 Ensure personnel are trained in manual handling and/or effectively supervised. If load is heavy or awkward, get help. DO NOT TRY TO LIFT ON YOUR OWN. Use team lifts for heavy, long or awkward loads and control and coordinate team movements with signals.
3 Supervisor/
Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
14 | P a g e
SWMS Title: Manual Handling SWMS NO. 002 Page 2 of 4
Work Method / Task Description Hazard
Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
Preparation: Assess workflow and work area.
Slips, trips and
falls.
2 Eliminate unnecessary manual handling- Use mechanical aids where possible. Allow for frequent rest periods and job rotation. Organise a smooth work flow. Ensure personnel are trained in safe lifting procedures. Ensure workplace is uncluttered and well lit & floor surfaces are even and non slip.
3 Supervisor/
Worker
Lift and carry objects.
Muscular skeletal
stress / injury
Slips, trips and
falls.
Lacerations and
abrasions.
Crush injuries.
2
2
2
2
Allow for frequent rest periods and job rotation. Ensure new workers are adequately supervised. Perform all movements in a controlled, balanced and comfortable position. Minimise repetitive bending, twisting and over reaching movements.
Use correct lifting techniques, including-
Position your feet as close as possible to the load.
Adopt a balanced position with your knees bent.
Get a safe secure grip diagonally across the object with the palms of your hands.fingertips.
Beware of sharp edged materials – wear safety gloves.
Keep your upper body erect and as straight as possible.
Tuck your chin in, draw your shoulders back and use your body weight to take up the load weight – ensure a proper grip.
Take a deep breath, keep your head up and begin to lift the load by straightening your legs.
Complete the lift with your head held straight.
Hold and carry the load close to your body to reduce the strain on your arms, shoulders and back.
Use your body weight to counter-balance the load weight by leaning slightly backwards as you move.
Use your feet to change direction – do not twist your body, hips or shoulders.
Avoid carrying loads that obstruct your view, particularly on inclines, declines or stairways.
Avoid repetitive lifts from below mid-thigh height and above shoulder height.
Avoid single handed repetitive lifts and avoid lifting while leaning over to reach the load.
3
3
3
3
Worker
Worker
Worker
Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
15 | P a g e
SWMS Title: Manual Handling SWMS NO. 002 Page 3 of 4
Work Method / Task Description Hazard
Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
Lower and stack objects Muscular skeletal stress/injuries.
2 Ensure your feet and body face the spot in which the object is to be placed.
Bend your knees, keep your back up straight and hold the object close to your body.
3 Worker
Additional items identified on site
Supervisor/
Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
16 | P a g e
SWMS Title: Manual Handling SWMS NO. 002 Page 4 of 4
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Industry and Site induction All personnel to maintain a tidy work site.
Personal protection equipment (PPE) to be worn at all times.
Supervisor and employees to be instructed in correct Manual Handling
techniques. See NECA Toolbox Talk 61 - Manual Handling.
No previous experience required. Seek assistance with manual handling when required Supervisor to be trained in hazard identification, risk assessment and control
eg, SWMS
Supervisor to carry out daily inspections of work site for hazards.
Engineering Details / Certificates /
WorkCover Approvals / Australian
Standards
Referenced – Codes of Practice / Regulations / Legislation
All PPE used to meet & be maintained to
Australian Standards
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe Electrical
Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act Regulations 1947,
Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997, Electrical
Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
All States: Code of Practice - Compliance Code Prevention of Falls. Code of Practice Manual Handling
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Manual handling aids- trolley, stands, winches etc
Ensure manual Handling Aids are fit for puropose Hard Hat, Ear protection, Eye protection, Safety Vest
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
17 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: WORKING AT HEIGHTS SWMS NO. 003 Page 1 of 4
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
Working at heights can be in the form of :-
Falling.
1
Recommended controls for fall protection can be in three forms or a
combination of either :-
3 Supervisor/
Worker
Working on a roof, on the top of a tank, from an elevated
platform, from a ladder, a building façade, a building under
construction / renovation, working on a structure e.g. steel,
timber, concrete, slippery surface, sloping surface, working
over water, in or near lift shafts, within 2.0 m of an edge where
there is the potential to fall 2.0 m or more.
Personal injury 2
1. Fall prevention – placing a physical barrier to
prevent personnel working where they can fall
e.g. Walls, Mesh screening, Guardrailing / Handrails, Fixed barricading
set back 3.0m from any fall potential
2. Fall restraint – limiting personnel from reaching the point of potential
fall
e.g. Parachute type full body safety harness with a
limited length inertia reel connected to a fixed point or static line.
Roofing kneel boards to spread the load over a span
3 Supervisor/
Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
18 | P a g e
SWMS Title: WORKING AT HEIGHTS SWMS NO 003 Page 2 of 4
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
Or
Where there is potential for personnel to come within 2.0m of
falling 2.0m or more
3. Fall arrest – providing personnel with protection if they do fall
e.g. Industrial safety nets, parachute type full body safety harness
connected to a fixed length lanyard and shock absorber connected to a
fixed point or static line, or a parachute type full body safety harness
connected to an inertia reel to a fixed point
or static line
Further forms of working at height which provide varying degrees of
protection include :-
Swing stages, Mast climbing work platforms, Scaffolding, Crane man /
work box, Elevated Work Platforms, Ladders – in some cases personnel
need to be trained and certificated to operate this equipment
Additional items identified on site Supervisor/W
orker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
19 | P a g e
SWMS Title: WORKING AT HEIGHTS SWMS NO. 003 Page 3 of 4
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Personnel will need to be trained and confident at
working at heights
Supervisor to carry out daily inspections of work site for hazards. Supervisor to be trained in hazard identification, risk assessment and
control eg, SWMS
Industry and Site induction
All personnel to maintain tidy work area on site at all times. Personal
Protective Equipment (PPE) to be worn at all times on site.
Supervisor to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
Appropriate Certificates of Competency will be required
by personnel for particular operations working at height,
e.g. scaffolding, dogman, rigger, crane operator, elevated
work platform operations
Barricading to be used as appropriate to protect others from working below
elevated work.
Fall protection equipment to be worn where required
Training in the use of specific plant and inspection and maintenance of
equipment to be conducted for the type of equipment / plant to be
used.
Engineering Details / Certificates / WorkCover
Approvals / Australian Standards
Referenced – Codes of Practice / Regulations / Legislation
Floor capacity sufficiently engineered to carry weight of
elevated work platform/s. Australian Standard AS 4576
Scaffolding General, AS 2550 Cranes – Safe Use. AS 1891
Industrial Fall Arrest Systems and Devices, AS 2626
Industrial Safety Belts and Harnesses.
All PPE used to meet & be maintained to Australian
Standards
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for
Safe Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical
Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act
Regulations 1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act
1997, Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
All States: Code of Practice - Compliance Code Prevention of Falls.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
20 | P a g e
SWMS Title: WORKING AT HEIGHTS SWMS NO. 003 Page 4 of 4
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Hazard Identification to be conducted for plant used eg. Scissor lift, boom lift, cherry
picker, cranes, swingstages, crane work box. Ensure compatibility of components
particularly for fall protection / restraint / arrest equipment
Cranes, Elevated Work Platform/s, scaffolding in
accordance with manufacturers recommendations Fall
arrest / protection equipment must be checked prior to
every use by a competent, trained person
Hard Hat, Ear protection, Eye protection, Safety Vest
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
21 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: WORKING NEAR SWITCHBOARDS – RCD TESTING SWMS NO. 004 Page 1 of 2
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual Risk Person
Responsible
1. Ensure area is free from Hazards (including rain) Trips and Falls Electric Shock
3 Place “work in progress” signs in area If switchboard is located outside, and it is raining, works shall not commence.
2. Confirm with client power is able to be isolated whislt conducting test as power shut down could impact important equipment. Ensure PC’s are shut down FIRST.
NIL
3
Confirm with client through use of “As Installed” Drawings. DO NOT complete test if there is any doubt.
3. Push button RCD Test Potential Electric shock
3
Ensure Switchboard internal cover is in place so no contact can be made with live parts
4. Operating Trip Time RCD Test – Check switchboard legend to confirm the outlets on the circuit prior to commencing test
Potential Electric shock
3
Ensure Switchboard internal cover is in place so no contact can be made with live parts
5. Record results
NIL
3
6. Reinstate circuit breaker to original status
Potential Electric shock 3 Ensure there is no load on circuit breaker when resetting where practical.
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
22 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
23 | P a g e
Safe Work Method Statement Title : WORKING NEAR SWITCHBOARDS – Testing RCD’s SWMS NO. 004 Page 2 of 2
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Tradesman and others trained and competent in
the testing of RCD’s
Technician to carry out daily inspections of work site for hazards. Technician to be trained in risk identification, assessment and control
eg, Job Safety Analysis (JSA).
Appropriate industry and site induction.
All personnel to maintain tidy work area on site at all times. Personal Protective
Equipment (PPE) to be worn at all times on site.
All personnel to carry and maintain a First Aid Kit.
Technician to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
No previous particular experience required On the job skills training to be conducted by Supervisor to personnel.
Engineering Details / Certificates /
WorkCover Approvals / Australian
Standards
Referenced – Codes of Practice / Regulations / Legislation
Testing to be completed in accordance with
AS/NZS 3760:2010 and AS/NZS 3012 where
applicable
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe
Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act Regulations
1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997,
Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
All States: Code of Practice - Compliance Code Prevention of Falls, Managing Electrical Risks in the Workplace
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
RCD Tester RCD Testers to be tested annually Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/longs sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
24 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: WORKING NEAR SWITCHBOARDS – Exit and Emergency Lighting SWMS NO. 005 Page 1 of 2
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
1. Ensure area is free from Hazards Trips and Falls 5 Place “work in progress” signs in area
2. Confirm with client testing is able to be conducted NIL 5 Confirm with client through use of “As Installed” Drawings. DO NOT
complete test if there is any doubt.
3. Push button Exit and Emergency Lighting Test
Potential Electric shock
5
Ensure Switchboard internal cover is in place so no contact can be made
with live parts
4. Operating Trip Time Exit and Emergency Lighting Test –
Check switchboard legend to confirm the lights on the circuit
prior to commencing test
Potential Electric shock
5
Ensure Switchboard internal cover is in place so no contact can be made
with live parts
5. Record results
6. Cleaning of Exit and Emergency light fittings and tube
replacement
Falls Refer SWMS 006 and SWMS 001.
7. Reset Exit and Emergency Lighting test switch NIL
Falls
Potential Electric shock
5
3
5
Ensure Switchboard internal cover is in place so no contact can be made
with live parts
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
25 | P a g e
Work Method Statement Title : WORKING NEAR SWITCHBOARDS –EXIT AND EMERGENCY LIGHT TESTING SWMS NO. 005 Page 2 of 2
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Tradesman and others trained and competent in the
testing of Exit and Emergency Lighting
Technician to carry out daily inspections of work site for hazards. Technician to be trained in risk identification, assessment and control
eg, Job Safety Analysis (JSA).
Appropriate industry and site induction.
All personnel to maintain tidy work area on site at all times. Personal
Protective Equipment (PPE) to be worn at all times on site.
All personnel to carry and maintain a First Aid Kit.
Technician to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
No previous particular experience required On the job skills training to be conducted by Supervisor to personnel.
Engineering Details / Certificates / WorkCover
Approvals / Australian Standards
Referenced – Codes of Practice / Regulations / Legislation
Testing to be completed in accordance with AS/NZS
2293
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe
Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act
2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act
Regulations 1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997,
Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
All States: Code of Practice - Compliance Code Prevention of Falls, Managing Electrical Risks in the Workplace
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Ladders complying with the relevant part of Australian
Standard AS 1892.
Ladders to be checked daily. Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/long sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
26 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: ELECTRICAL TESTING AND TAGGING to AS/NZS 3760:2010 SWMS NO. 006 Page 1 of 4
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
1.Confirm workplace and task requirements. Ensure area is free from Hazards. Confirm with client testing is able to be conducted.
Site specific issues Worker safety Public access and unauthorised persons
3 3 3
Do inspection and review tasks. Check test equipment and PPE, consult with workers involved Clear area and use appropriate barricades and signage. Place ATS “work in progress” signs in area Observe No live work policy DO NOT complete test if there is any doubt as to the impact of the test on work systems. Ask Client to power down any equipment prior to testing
3 3 3
Sup./Worker Worker Worker
2.Ensure that work complies with AS3760 Check operation of test equipment.
Inadequate knowledge Overlook fault
1 Person undertaking work must be competent Refer to codes and standard Involve employees in preparation Plug test equipment in to Portable RCD before use
3 Worker
3.Unplug equipment from the supply. Electric shock 1 Switch off at socket and disconnect plug. Ensure plug is in vision when disconnecting from socket
3 Worker
4.Undertake visual and physical inspection for damage and defects in appliance, accessories, connectors, plugs and extension outlet sockets.
Minor cuts from sharp edges
3 Apply due care in inspection Wear protective gloves where appropriate Ensure items are unplugged prior to commencing visual inspection
3 Worker
5.Check flexible cords are effectively anchored to equipment, plugs and sockets.
Hand injuries and cuts 3 Apply due care in inspection Wear protective gloves where appropriate Ensure items are unplugged prior to commencing visual inspection
3 Worker
6. If item passes Visual test, test earth continuity resistance not exceeding 1 ohm. Test insulation resistance not less than 1 megohm.
Hand injuries and cuts 3 Apply due care in inspection Wear protective gloves where appropriate
3 Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
27 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: ELECTRICAL TESTING AND TAGGING to AS/NZS 3760:2010 SWMS NO. 006 Page 2 of 4
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
7.Alternatively use leakage current test at rated voltage Class I – 5mA max Cords and Class II – 1mA max
Electric shock Note the protective earth conductor may be live whilst testing
1 Protect equipment with RCD or isolating transformer. Refer to stringent precautions to be followed when doing live testing in the COP Low voltage electrical work and prepare a separate risk assessment and SWMS for this work Confirm operating procedures of any infamilar equipment prior to completing Power Up test.
3 Worker
8.Prepare and fit tag to compliant equipment. If a retest site, remove previous tag. Record results using ATS system. Return passed items to service.
N/A N/A Tags do not have to be colour coded.
Worker
9. Prepare and fit fail tag and Danger tag to non compliant equipment. Take faulty items out of service and advise client of issue so client can arrange repair / replacement. Record results using ATS system.
N/A N/A N/A Worker Client
10. Return item to normal operation
N/A N/A N/A Worker Client
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
28 | P a g e
SWMS Title: ELECTRICAL TESTING AND TAGGING to AS/NZS 3760:2010 SWMS NO. 006 Page 3 of 4
Personnel Qualifications and Experience
Required
Personnel Duties and Responsibilities Training Required to Complete Work
Tradesman and others trained and competent in the
testing of Portable Electrical Appliances
Appropriate industry and site induction.
Technician to carry out daily inspections of work site for hazards.
All personnel to maintain tidy work area on site at all times. Personal Protective
Equipment (PPE) to be worn at all times on site.
Technician to ensure test equipment and power supplies have been inspected
tested and tagged.
All personnel to carry and maintain a First Aid Kit.
Technician to ensure test equipment is verified in accordance with the
manufacturers specifications
Stop work rather than accept a safety risk.
On the job skills training to be conducted by Supervisor to personnel.
Person to be trained in testing either as an electrician or a certified
Portable Appliance Tester (PAT).
Technician to be trained in risk identification, assessment and control
eg, Job Safety Analysis (JSA).
Technician to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
Engineering Details / Certificates / WorkCover Approvals /
Australian Standards
Referenced – Codes of Practice / Regulations / Legislation
AS/NZS 3760 and client’s specifications.
All PPE used to meet & be maintained to Australian Standards
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of
Practice for Safe Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for
Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013,
Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945,
Electricity Act Regulations 1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and
Administration Act 1997, Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
All States: Code of Practice Manual Handling, Managing Electrical Risks in the Workplace
Appliance Tagging Services Pty Ltd Safe Work Method Statements
29 | P a g e
SWMS Title: ELECTRICAL TESTING AND TAGGING to AS/NZS 3760:2010 SWMS NO. 006 Page 4 of 4
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Insulation resistance meter (mega) and ohmmeter.
Portable Appliance Tester unit where appropriate.
RCD or isolation transformer.
Test instruments to be checked daily.
All PPE and test equipment to be checked before use.
PAT to be verified annually or in accordance with the manufacturers
specifications
Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/long sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
30 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: VISUAL ONLY RISK ASSESSMENT OF PORTABLE ELECTRICAL APPLIANCES AND LEADS – EQUIPMENT NOT SHUT DOWN SWMS NO. 007 Page 1 of 4
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
1.Confirm workplace and task requirements. Ensure area is free from
Hazards. Confirm with client testing is able to be conducted.
Ensure client is aware VISUAL ONLY RISK ASSESMENT is not
in accordance with AS/NZS 3760:2010.
Site specific issues
Worker safety
Public access and
unauthorised persons
3
3
3
Ask Client to power down any equipment prior to testing where
possible. If not possible, follow this procedure. Do inspection and
review tasks.
Check test equipment and PPE, consult with workers involved
Clear area and use appropriate barricades and signage. Place ATS
“work in progress” signs in area
DO NOT complete assessment if there is any doubt as to the impact of
the assessment on work systems.
3
3
3
Sup./Worker Worker Worker
2. Undertake visual risk assessment only for damage and defects on
the exterior of the appliance, including accessories, connectors,
leads, plugs and extension outlet sockets.
Neck strain;
Exposure to heat;
Exposure to moving
parts;
Electric shock
3 Ensure client is aware plug pins cannot be inspected.
Apply due care in risk assessment. Do not expose self to uncontrolled
hazards.
Where 100% of item cannot be seen visually, note on ATS job sheet
and advise client. Client to advise next steps and ATS to note all
clients requests on job sheet – Client to sign off. Do not tag appliance.
3 Worker
3.Where deemed safe to do so, physical risk assessment to be
conducted.
Ensure client is aware plug pins cannot be inspected.
Electric shock
Exposure to heat;
Exposure to moving
parts;
1 Apply due care in risk assessment. Only conduct physical assesment
where 100% of item has passed visual assesment.
Wear protective gloves where appropriate
Ensure client is aware plug pins cannot be inspected.
Where 100% of item cannot be seen visually, do not conduct physical
assessment and advise client. Do not tag appliance.
Client to advise next steps and ATS to note all clients requests on job
sheet – Client to sign off.
1 Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
31 | P a g e
SWMS Title: VISUAL ONLY RISK ASSESMENT OF PORTABLE ELECTRICAL APPLIANCES AND LEADS – EQUIPMENT NOT SHUT DOWN SWMS NO. 007 Page 2 of 4
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
4.Check flexible cords are effectively anchored to equipment, plugs
and sockets.
Hand injuries and
cuts
Electric shock
1 Apply due care in inspection
Wear protective gloves where appropriate
Only conduct physical asssessment where 100% of item has passed
visual assesment.
1 Worker
5. If item passes Visual and Physical risk assessment, apply ATS visual
risk assesment “pass” tag to item and complete assessment and re-
assessment date. Record risk assessment using ATS system.
Neck strain;
Exposure to heat;
Exposure to moving
parts;
Electric shock
3 ATS specific VISUAL ONLY tag to be applied.
Re-assessment date to be based on environment. Maximum 12months.
Ensure client is aware risk assessment “pass” tags are not compliant
with AS/NZS 3760:2010
Apply due care in applying tag to easily accessible area of appliance
3 Worker
6. Advise client of items “failing” risk assesment.
Record risk assessment using ATS system. Appy ATS danger tag to
non compliant equipment. Ask client to take out of service. Client to
arrange repair / replacement.
Neck strain;
Exposure to heat;
Exposure to moving
parts;
Electric shock
1 Client to advise course of action for failed/faulty items that are unable
to be shut down.
Only fit ATS Danger tag where safe to do so.
DO NOT apply ATS risk assessment “pass” tag
Apply due care in applying tag to easily accessible area of appliance
Note all actions taken on Daily Sheet and request client sign off
1 Worker
Client
Additional items identified on site
Supervisor/
Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
32 | P a g e
SWMS Title: VISUAL ONLY RISK ASSESMENT OF PORTABLE ELECTRICAL APPLIANCES AND LEADS – EQUIPMENT NOT SHUT DOWN SWMS NO. 007 Page 3 of 4
Personnel Qualifications and Experience
Required
Personnel Duties and Responsibilities Training Required to Complete Work
Tradesman and others trained and competent in the
testing of Portable Electrical Appliances
Appropriate industry and site induction.
Technician to carry out daily inspections of work site for hazards.
All personnel to maintain tidy work area on site at all times. Personal Protective
Equipment (PPE) to be worn at all times on site.
Technician to ensure test equipment and power supplies have been inspected
tested and tagged.
All personnel to carry and maintain a First Aid Kit.
Technician to ensure test equipment is verified in accordance with the
manufacturers specifications
Stop work rather than accept a safety risk.
On the job skills training to be conducted by Supervisor to personnel.
Person to be trained in testing either as an electrician or a certified
Portable Appliance Tester (PAT).
Technician to be trained in risk identification, assessment and control
eg, Job Safety Analysis (JSA).
Technician to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
Engineering Details / Certificates / WorkCover Approvals /
Australian Standards
Referenced – Codes of Practice / Regulations / Legislation
AS/NZS 3760 and client’s specifications.
All PPE used to meet & be maintained to Australian Standards
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of
Practice for Safe Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for
Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013,
Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945,
Electricity Act Regulations 1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and
Administration Act 1997, Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
All States: Code of Practice Manual Handling, Managing Electrical Risks in the Workplace
Appliance Tagging Services Pty Ltd Safe Work Method Statements
33 | P a g e
SWMS Title: VISUAL ONLY RISK ASSESMENT OF PORTABLE ELECTRICAL APPLIANCES AND LEADS – EQUIPMENT NOT SHUT DOWN SWMS NO. 007 Page 4 of 4
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Insulation resistance meter (mega) and ohmmeter.
Portable Appliance Tester unit where appropriate.
RCD or isolation transformer.
Test instruments to be checked daily.
All PPE and test equipment to be checked before use.
PAT to be verified annually or in accordance with the manufacturers
specifications
Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/longs sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
34 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: VEHICLE HAZARDS AND VEHICLE SECURITY SWMS NO. 008 Page 1 of 2
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
1. Storage of Test Equipment and Consumables (Tags, EPOD’s, etc) in
Vehicle
Projecticle
3 Follow ATS guidelines and standard vehicle packing practices. Ensure
all items are secured in the rear of the vehicle.
Worker
2. Vehicle security Breaking and Entering
/ Theft
3 Ensure vehicle is locked at all times and parked in a secure area when
unattended for a period of time.
Refer to ATS Policies and Procedures manual for further details on ATS
Vehcile Policy.
Worker
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
35 | P a g e
Work Method Statement Title : VEHICLE HAZARDS AND SECURITY SWMS NO. 008 Page 2 of 2
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Tradesman and others holding a Vehicle licence
Technician to carry out daily inspections of vehicle for hazards.
Completion of assesment prior to being awarded drivers licence
All personnel to maintain tidy vehicle at all times
All personnel to carry and maintain a First Aid Kit.
Engineering Details / Certificates /
WorkCover Approvals / Australian
Standards
Referenced – Codes of Practice / Regulations / Legislation
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe
Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act Regulations
1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997,
Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Van – Holden Combo or equivalent
Van – Mercedes Benz Vito or equivalent
Vehicle to be serviced in accordance with manufacturers specifications and maintained as required
Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/long sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
36 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: MICROWAVE RADIATION LEAKAGE TESTING SWMS NO. 009 Page 1 of 2
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
1. Following visual inspection and electrical test and tag in
accordance with SWMS 007, place 1 cup of water in Microwave.
Worker
2. Set Microwave on HIGH and press START – Operating time is 30
seconds max
Boiling Water with
possibility of scalding
Do not operate Microwave for longer than 60 seconds to reduce
instances of boiling water
Worker
3. Hold the tester steady 5-10cm away from surfaces and run the
device along and around all door seal and hinge areas and diagonally
across window face to detect for leakage from the oven.
Worker
4. Record the highest value displayed during the test using the
Supernova DATA ONLY entry.
Worker
5. Dispose of cup of water immediately to appropriate waste area. Boiling Water with
possibility of scalding
Do not operate Microwave for longer than 60 seconds to reduce
instances of boiling water
Worker
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
37 | P a g e
Work Method Statement Title : MICROWAVE RADIATION LEAKAGE TESTING SWMS NO. 009 Page 2 of 2
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Tradesman and others trained and competent in
the radiation testing of Microwaves
Technician to carry out daily inspections of work site for hazards.
Technician to be trained in risk identification, assessment and control
eg, Job Safety Analysis (JSA).
Appropriate industry and site induction.
All personnel to maintain tidy work area on site at all times. Personal Protective
Equipment (PPE) to be worn at all times on site.
All personnel to carry and maintain a First Aid Kit.
Technician to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
No previous particular experience required On the job skills training to be conducted by Supervisor to personnel.
Engineering Details / Certificates / WorkCover
Approvals / Australian Standards
Referenced – Codes of Practice / Regulations / Legislation
AS/NZS 3350.2.25:2001 Safety of Household and Similar
Electrical Appliances – Particular Requirements for
Microwave ovens (IEC 60335-2-25:1996, MOD)
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for
Safe Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety
Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act
Regulations 1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act
1997, Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Microwave Leakage Tester Check equipment annually Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/long sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
38 | P a g e
Appliance Tagging Services Pty Ltd 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: LEVEL 1 AND LEVEL 2 INSPECTION OF PORTABLE FIRE EXTINGUISHERS SWMS NO. 010 Page 1 of 3
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual Risk Person
Responsible
1. Report to site contact and Sign-in on contractor book, do site Induction and obtain access keys.
3 3 Worker
2. Ensure area is free from Hazards 3 Place “work in progress” signs in area
3 Worker
3. Conduct inspection of equipment in accordance with
Australian Standard AS1851 Part 1.
Cutting fingers on metal service tag or sharp
edges on extinguisher cylinder skirt.
Pinching fingers when using tagging punch.
3
Read Contractor Health & Safety Guidelines provided by
client. Wear correct PPE equipment (gloves, steel cap
boots).
Apply correct manual handling protocols.
3
Worker
4. Removal of Extinguishers for levels 4 & 5 service. Placing
extinguishers on trolley and taking them to vehicle. Loading
into plastic basket ready for transportation back to BFP.
Extinguishers to be transported upright with all pull pins
installed. Loading Extinguishers into vehicle.
Muscle strain when lifting large extinguishers
off wall hook or when inverting dry powder
extinguishers.
Area left unprotected when extinguisher has
been removed.
Extinguisher falling off trolley.
Muscle strain when lifting large extinguishers
3
Provide loan extinguisher in place of unit to be removed.
Ensure extinguisher pull pin is secure and place on
trolley ensuring it is positioned towards the centre. Limit
number of extinguishers on trolley to maximum 8 units.
Apply correct manual handling protocols.
3
Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
39 | P a g e
Safe Work Method Statement Title : LEVEL 1 AND LEVEL 2 INSPECTION OF PORTABLE FIRE EXTINGUISHERS SWMS NO. 010 Page 2 of 3
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual Risk Person
Responsible
5. During service and on completion ensure all hand tools are
placed back into service pouch and remove any rubbish caused
by service.
Trips and Falls 3 Tidy up work area at regular intervals and keep area free
of tools on ground, prevent a tripping hazard.
3 Worker
6. Record results of service on Certificate of Inspection (COI)
before moving to the next piece of equipment.
NA
NA
NA Worker
7. Upon completion and/or at the end of each day return
access keys to site contact, and Sign-out on contractor book.
Trips and Falls 3 N/A 3 Worker
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
40 | P a g e
Safe Work Method Statement Title : LEVEL 1 AND LEVEL 2 INSPECTION OF PORTABLE FIRE EXTINGUISHERS SWMS NO. 010 Page 3 of 3
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Technicians trained and competent in the testing of
Fire Extinguishers
Technician to carry out daily inspections of work site for hazards. Technician to be trained in risk identification, assessment and control
eg, Job Safety Analysis (JSA).
Appropriate industry and site induction.
All personnel to maintain tidy work area on site at all times. Personal Protective
Equipment (PPE) to be worn at all times on site.
All personnel to carry and maintain a First Aid Kit.
Technician to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
No previous particular experience required On the job skills training to be conducted by Supervisor to personnel.
Engineering Details / Certificates /
WorkCover Approvals / Australian
Standards
Referenced – AS1851 - 2012
Testing to be completed in accordance with
AS/NZS 1851
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe
Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act Regulations
1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997,
Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/long sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
41 | P a g e
Appliance Tagging Services Pty Ltd 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: LEVEL 1 AND LEVEL 2 SERVICE FIRE HOSE REELS SWMS NO. 011 Page 1 of 3
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Resid
ual Risk
Person Responsi
ble
1.Confirm workplace and task requirements.
Ensure area is free from Hazards. Confirm with
client testing is able to be conducted.
Site specific issues
Worker safety
Public access and unauthorised persons
3
3
3
Do inspection and review tasks.
Check test equipment and PPE, consult with workers
involved
Clear area and use appropriate barricades and signage.
Place ATS “work in progress” signs in area
3
3
3
Sup./Worker
Worker Worker
2. Conduct inspection of equipment in accordance
with Australian Standard AS1851 Part 2.
Cutting fingers on metal service tag or sharp edges on hose
reel rim.
Pinching fingers when using tagging punch or reeling up hose.
Muscle strain when unreeling or reeling up hose.
3
Read Contractor Health & Safety Guidelines provided by
client. Wear correct PPE equipment (gloves, steel cap
boots). Apply correct manual handling protocols.
3 Worker
3. Level 2 service unreeling 36 metres of hose,
discharging water for flow test and reeling up hose.
Potential to cause a false alarm if hose reels are fitted with
Pressure or Flow switches that interface with the building’s
fire alarm system.
Slip, Trip or Fall when hose has been unreeled for flow test
and if water has dripped onto hard surface floor. Potential to
jamb fingers/hand between reel and drum whilst rewinding
3
Arrange isolation of relevant zones on FIP prior to flow
test, if applicable.
Provide “Men at Work” warning signage and/or bollards to
alert occupants in area. Discharge minimum amount of
water into bucket or if practicable into a water drain. Use
absorbent cloth to wipe any water spill. Apply correct
manual handling protocols.
Rewind drum facing front plate, ensuring wearing
protective gloves and proceed in an even manner.
3
Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
42 | P a g e
Work Method Statement Title : LEVEL 1 AND LEVEL 2 SERVICE FIRE HOSE REELS SWMS NO. 011 Page 2 of 3
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention
Residual Risk
Person Responsible
4. During service and on completion ensure all hand
tools are placed back into service pouch and
remove any rubbish caused by service.
Slip, Trip or Fall.
3
Tidy up work area at regular intervals
and keep area free of tools on
ground, minimise a tripping hazard.
3
.
Worker
5. Record results of service on Certificate of
Inspection (COI) before moving to the next piece of
equipment.
NIL
3
NA
3
Worker
6. Upon completion of service report site contact,
return access keys and Sign-out on contractor
register.
NIL 3
NA 3 Worker
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
43 | P a g e
Work Method Statement Title : LEVEL 1 AND LEVEL 2 SERVICE FIRE HOSE REELS SWMS NO. 011 Page 3 of 3
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Technicians trained and competent in the testing of of
Fire Hose Heels
Technician to carry out daily inspections of work site for hazards. Technician to be trained in risk identification, assessment and control
eg, Job Safety Analysis (JSA).
Appropriate industry and site induction.
All personnel to maintain tidy work area on site at all times. Personal
Protective Equipment (PPE) to be worn at all times on site.
All personnel to carry and maintain a First Aid Kit.
Technician to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
No previous particular experience required On the job skills training to be conducted by Supervisor to personnel.
Engineering Details / Certificates / WorkCover
Approvals / Australian Standards
Referenced – AS1851 - 2012
Testing to be completed in accordance with AS 1851
Part 2.
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe
Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act
2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act
Regulations 1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997,
Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/long sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
44 | P a g e
Appliance Tagging Services Pty Ltd 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: MONTHLY AND ANNUAL INSPECTION FIRE HYDRANTS SWMS NO. 012 Page 1 of 3
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
1.Confirm workplace and task requirements. Ensure
area is free from Hazards. Confirm with client testing
is able to be conducted.
Site specific issues
Worker safety
Public access and unauthorised
persons
3
3
3
Do inspection and review tasks.
Check test equipment and PPE, consult with workers involved
Clear area and use appropriate barricades and signage. Place ATS
“work in progress” signs in area
3
3
3
Sup./Worker Worker Worker
2. Report to site contact and Sign-in on contractor
book, do site Induction and then proceed to obtain
access keys. Conduct inspection of equipment in
accordance with Australian Standard AS1851 Part 4.
Slip, Trip or Fall where hydrants are
located on stair landings
3 Read Contractor Health & Safety Guidelines provided by client. Wear
correct PPE equipment (gloves, steel cap boots).
Apply correct manual handling protocols.
3 Worker
3. Annual Presence of Water Check discharging water.
Potential to cause a false alarm if
hydrants are fitted with Pressure or
Flow switches that interface with the
building’s fire alarm system.
Slip, Trip or Fall when hydrant has
been discharged for presence of
water check and water has dripped
onto hard surface floor.
3 Arrange isolation of relevant zones on FIP prior to presence of water
check.
Provide “Men at Work” warning signage and/or bollards to alert
occupants in area. Discharge minimum amount of water into bucket
or if practicable into a water drain. Use absorbent cloth to wipe any
water spill. Apply correct manual handling protocols.
3 Worker
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
45 | P a g e
Work Method Statement Title : LEVEL 1 AND LEVEL 2 SERVICE FIRE HOSE REELS SWMS NO. 011 Page 2 of 3
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
4. During service and on completion ensure all hand tools are placed
back into service pouch and remove any rubbish caused by service.
Record results of service on Certificate of Inspection (COI) before
moving to the next piece of equipment.
Slip, Trip or Fall.
3 Tidy up work area at regular intervals and keep area free of tools on
ground, minimise a tripping hazard.
3 Worker
5. Upon completion and/or at the end of each day return access keys
to site contact, and Sign-out on contractor book.
NIL NIL NA NA Worker
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
46 | P a g e
SWMS Title: MONTHLY AND ANNUAL INSPECTION FIRE HYDRANTS SWMS NO. 012 Page 2 of 3
Personnel Qualifications and
Experience Required
Personnel Duties and Responsibilities Training Required to Complete Work
Technicians trained and
competent in the testing of testing
of Fire Hydrants
Technician to carry out daily inspections of work site for hazards.
All personnel to maintain tidy work area on site at all times. Personal Protective Equipment (PPE) to be worn
at all times on site.
Technician to ensure equipment and power supplies have been inspected tested and tagged.
All personnel to carry and maintain a First Aid Kit.
Stop work rather than accept a safety risk.
On the job skills training to be conducted by Supervisor to personnel.
Person to be trained in testing of Fire Hydrants
Technician to be trained in risk identification, assessment
and control eg, Job Safety Analysis (JSA).
Technician to be appropriately trained, qualified and
competent in OH&S and electrical practices for the task.
Engineering Details / Certificates / WorkCover Approvals / Australian Standards Referenced – AS1851 - 2012
Testing to be completed in
accordance with AS 1851 Part
4
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe Electrical Work 1997,
Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act Regulations 1947, Electricity
(Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997, Electrical Industry
Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/long sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
47 | P a g e
Appliance Tagging Services Pty Ltd 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: WORKING OUTSIDE OF NORMAL BUSINESS HOURS SWMS NO. 013 Page 1 of 2
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
1.Confirm workplace and task requirements. Ensure area
is free from Hazards. Confirm with client testing is able
to be conducted. Identify any after hours security
procedures required.
Site specific issues
Worker safety
Public access and unauthorised
persons
3
3
3
Do inspection and review tasks.
Check test equipment and PPE, consult with workers involved
Clear area and use appropriate barricades and signage. Place ATS
“work in progress” signs in area
3
3
3
Sup./Worker Worker Worker
2. Report to site contact and Sign-in on contractor book.
Complete site Induction and obtain access keys. Make
arrangements for return of access keys.
Slip, Trip or Fall 3 Read Contractor Health & Safety Guidelines provided by client. Wear
correct PPE equipment. Apply correct manual handling protocols.
3 Worker
3. If no client staff are to remain on site while works are
being conducted, ensure ATS are aware.
Worker safety 3 Advise ATS you are the only one on site.
Make arrangements for regular “check-ins” to ensure worker safety
4. Ensure works are completed in accordance with
specification and SWMS
5. Return all access keys and ensure site is restored to
normal function as per SWMS
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
48 | P a g e
SWMS Title: WORKING OUTSIDE OF NORMAL BUSINESS HOURS SWMS NO. 013 Page 2 of 2
Personnel Qualifications and
Experience Required
Personnel Duties and Responsibilities Training Required to Complete Work
Technicians trained and
competent in the completion of
the tasks required
Technician to carry out daily inspections of work site for hazards.
All personnel to maintain tidy work area on site at all times. Personal Protective Equipment (PPE) to be worn
at all times on site.
Technician to ensure equipment and power supplies have been inspected tested and tagged.
All personnel to carry and maintain a First Aid Kit.
Stop work rather than accept a safety risk.
On the job skills training to be conducted by Supervisor to personnel.
Technician to be trained in risk identification, assessment
and control eg, Job Safety Analysis (JSA).
Technician to be appropriately trained, qualified and
competent in OH&S and electrical practices for the task.
Engineering Details / Certificates / WorkCover Approvals / Australian Standards
Testing to be completed in
accordance with applicable
Australian Standards
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe Electrical Work 1997,
Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act Regulations 1947, Electricity
(Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997, Electrical Industry
Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Plant / Equipment Required (Mobile or Static) Maintenance Checks / Calibration Intervals PPE to be utilised as required
Hard Hat, Ear protection, Eye protection, Safety Vest, Long pants/long sleeves
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.
Appliance Tagging Services Pty Ltd Safe Work Method Statements
49 | P a g e
Appliance Tagging Services Pty Ltd. 80 Patterson Road Bentleigh VIC 3204 ABN: 42 118 273 788
SWMS Title: WORKING ON SWITCHBOARDS – RCD TESTING BY LICENSED ELECTRICIAN ONLY SWMS NO. 014 Page 1 of 2
Person responsible for ensuring compliance with this SWMS:
Shankary Mahendran Contact Number: 1300 287 669 Date: 02/09/2014 Revision: 1
Project / Client: TBA / Appliance Test and Tag Location: TBA
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual Risk Person
Responsible
THIS SWMS IS ONLY TO BE FOLLOWED BY QUALIFIED AND LICENSED ELECTRICIANS
1. Ensure area is free from Hazards
Trips and Falls
5
Place “work in progress” signs in area
2. Confirm with client power is able to be isolated whislt
conducting test as power shut down could impact important
equipment. Ensure PC’s are shut down FIRST.
NIL
5
Confirm with client through use of “As Installed” Drawings. DO NOT
complete test if there is any doubt.
3. Ensure a spotter can see the switchboard at all times
4. Record the current position of all RCD’s.
Potential Electric shock
5
Ensure Switchboard internal cover is in place so no contact can be made
with live parts
5. Use appropriate tools to remove the eschcution of the
switchboard carefully
Potential Electric shock 5
Ensure Switchboard internal cover is in place so no contact can be made
with live parts
6. Perform all required RCD tests using appropriate tools and
methods
Potential Electric shock
5
Ensure Switchboard internal cover is in place so no contact can be made
with live parts
7. Record results NIL
8. Reinstate circuit breaker to original status Potential Electric shock 5
Ensure there is no load on circuit breaker when resetting where
practical.
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
50 | P a g e
Work Method Statement Title : WORKING ON SWITCHBOARDS – RCD TESTING BY LICENSED ELECTRICIAN ONLY SWMS NO. 014 Page 2 of 3
Work Method / Task Description Hazard Identification Risk Level
Recommended Actions / Controls for Prevention Residual
Risk Person
Responsible
9. Replace eschuction of the switchboard carefully
5
Additional items identified on site
RISK LEVELS: CLASS 1 (high), CLASS 2 (medium), CLASS 3 (low).
Appliance Tagging Services Pty Ltd Safe Work Method Statements
51 | P a g e
Safe Work Method Statement Title : WORKING ON SWITCHBOARDS – RCD TESTING BY LICENSED ELECTRICIAN ONLY SWMS NO. 014 Page 3 of 3
Personnel Qualifications and Experience Required Personnel Duties and Responsibilities Training Required to Complete Work
Electricians that are suitably trained and qualified in the
testing of RCD’s at the Switchboard
Electrician to carry out daily inspections of work site for hazards. Electrician to be trained in risk identification, assessment and control
eg, Job Safety Analysis (JSA).
Appropriate industry and site induction.
All personnel to maintain tidy work area on site at all times. Personal Protective
Equipment (PPE) to be worn at all times on site.
All personnel to carry and maintain a First Aid Kit.
Electrician to be appropriately trained, qualified and competent in
OH&S and electrical practices for the task.
Qualified and licensed electrician On the job skills training to be conducted by Supervisor to personnel. Qualified and licensed electrician
Engineering Details / Certificates / WorkCover
Approvals / Australian Standards
Referenced – Codes of Practice / Regulations / Legislation
Testing to be completed in accordance with
AS/NZS 3760:2010 and AS/NZS 3012 where
applicable
Victoria: Occupational Health and Safety Act 2004, Electricity Safety Act 1998, Electricity Safety (Installations) Regulations 1999, Code of Practice for Safe
Electrical Work 1997, Code of Practice for Fall Protection
New South Wales: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Practises for Construction Work
Queensland: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Safety Regulations 2013, Electrical Safety Act 2002
South Australia: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Western Australia: Occupational Health and Safety Act 1984, Occupational Health and Safety Regulations 1996, Electricity Act 1945, Electricity Act Regulations
1947, Electricity (Licencing) Regulations 1991
Tasmania: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011, Electrical Industry Safety and Administration Act 1997,
Electrical Industry Safety and Administration Regulations 1999
Northern Territory: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
ACT: Workplace Health and Safety Act 2011, Workplace Health and Safety Regulations 2011
Plant / Equipment Required (Mobile or
Static)
Maintenance Checks / Calibration Intervals
RCD Tester RCD Testers to be tested annually
Read, Understood & Signed by all Persons involved 1. 2.
3. 4. 5.
6. 7. 8.