The Brunswick School Athletic Building Kelly J. Doyle Greenwich, Connecticut Structural Option The Pennsylvania State University Spring 2003 Architectural Engineering Appendix B: Lighting Calculations & Specifications

Appendix B: Lighting Calculations & Specifications

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Appendix B: Lighting Calculations & Specifications

The Brunswick School Athletic Building Kelly J. Doyle Greenwich, Connecticut Structural Option

The Pennsylvania State University Spring 2003 Architectural Engineering

Appendix B: Lighting Calculations & Specifications

Page 2: Appendix B: Lighting Calculations & Specifications

Prismalume luminaires are theperfect fixtures for a variety of heavy-duty high bay applications includingindustrial, commercial and educa-tional facilities.

Prismalume luminaires are availablein a choice of six rugged prismaticglass reflectors, efficiently controllinglight for exceptional visibility.

Available in a wide range of HIDlamps and ballasts, Prismalumeluminaires deliver required lightinglevels in an energy efficient manner.

Robust design characterizesPrismalume luminaires, fromcorrosion resistant materials andcoatings to long lasting borosilicateprismatic glass reflectors.

Prismalume luminaires feature tool-less mechanisms and open glassoptics that simplify installation andoptimize maintenance.

PRISMALUME®

HL-755 8/02

Page 3: Appendix B: Lighting Calculations & Specifications

2

PRISMALUME®

HOLOPHANE®

• Choice of factory set distributions

• Thermal shock resistant prismatic glass reflectors

• Thermoset white polyester powder paint

• Die cast aluminum ballast housing

• UL/CUL listed

Gyms and field houses

Gymnasiums, swimming pools,field houses and multi-purposerooms demand a multi-purposelighting system. Basketball, vol-leyball and tennis require a totallyilluminated environment. Uniformvertical illumination is equally im-portant as illumination on theplaying surface.

Industrial

Machinery and other manufactur-ing equipment along with the sur-rounding area all interact with theworker’s ability to see and pro-duce products efficiently, safelyand to exacting standards. Thevalue provided by Prismalumereflectors is the result of a precisecombination of horizontal andvertical footcandles. This bal-anced illumination improves theability to see and provides anoverall level of visual comfort.

The engineered combination ofuplight and downlight providessuperior vertical illumination for awide variety of applications in-cluding warehouse aisle lighting.

Page 4: Appendix B: Lighting Calculations & Specifications

PRISMALUME®

3 HOLOPHANE®

INDUSTRIAL HIGH BAYS

RETAIL STORES

GYMNASIUMS

ASSEMBLY AREAS

WAREHOUSES

CONVENTION CENTERS

Retail

The merchandising objective is tocreate environments that positivelyinfluence the buying decision.

Visually appealing, efficient illumin-ation from a Prismalume luminaireis the optimum lighting choice.

Prismalume luminaires provideuniform illumination where goodsare displayed on horizontal tablesand fixtures. Gondolas now rangefrom 2.13m (7’) in grocery areas to6.10m (20’) in newer warehousestyle stores. Such vertically displayedmerchandise is more visible underPrismalume’s prismatic glassreflectors. Interior store signage isbrightly illuminated by the upwardcomponent of light fromPrismalume luminaires.

Efficient lighting of thevisual environment

Prismalume reflectors providemaximum efficiency for flexibilityof design. The unique prismaticglass reflector system coupledwith a wide selection of HIDlamps and wattages means anextensive choice of distributionsare available to tailor yourlighting design to the application.

The unique balance of uplightand downlight from Prismalumeluminaires provides outstandinglighting solutions for countlessapplications.

Page 5: Appendix B: Lighting Calculations & Specifications

4

PRISMALUME®

HOLOPHANE®

1 Zinc plated steel yoke:Quickly secures reflector to housingfor long life and easy installation.

2 Open top for self-cleaning:Reduces need for constantmaintenance.

3 Non-adjustable easilyinstalled dual actionsuspension lugs: Properlypositions and locks reflector in placefor designed photometrics.

4 Open prismatic borosili-cate glass reflector: Lowelectro-static charge minimizes dirtbuild-up.

5 Zinc plated steel rods andrings: Supports and protects glassreflector.

Prismatic glass reflectors

• Proven performance for over100 years.

• Choice of six highly efficientreflectors.

• Provides an excellent balanceof horizontal and verticalillumination.

• Prismatic glass reflectorsminimize brightness from innersurface.

• Glass reflectors will not pit orcorrode in normal industrial use.

• Endural® borosilicate glassreflectors resist thermal shock andare designed to withstand theheat generated by efficient HIDlamps.

123

4

5

Highly efficient luminaires

The overall efficient performanceof Prismalume luminaires canresult in fewer fixtures providingthe designed illumination levels.Fewer fixtures reduce installationand operating costs.

Unlike aluminum or plastic reflec-tors, borosilicate glass reflectorsare not subject to permanent de-terioration caused by industrialenvironments and do not presentthe additional safety concerns ofplastic reflectors.

Page 6: Appendix B: Lighting Calculations & Specifications

PRISMALUME®

5 HOLOPHANE®

400-1000W ballast shown

150-400W ballast shown

Rugged ballast assembly

• Die cast aluminum housingcombines corrosion resistancewith mechanical strength for therugged industrial environment.

• Mounting plate spins onto.75” NPT conduit and providessecure attachment for the slideon housing while the wirewaycover encloses the wiringchamber and secures housing tothe conduit.

• Seven stage pretreating of thehousing is followed by a sprayedon polyester powder paint, curedand baked on at 218°C. Thisexceeds ASTM standard practicefor hardness, humidity, impactand salt spray resistance toprevent cross hatch creep,fading, cracking, and otherweather related deterioration.

• Pre-wired, porcelain enclosedsocket with corrosion resistant,nickel plated lamp grip screwshell, is attached to the housingto provide specified lightingdistribution from a choice ofglass reflectors.

• UL listed 1598 55°C damplocation as standard, with op-tional 65°C listing available.

• Balanced mounting frommalleable cast iron hooks andloops without field adjustment.

• High power factor (over 90%)copper wound ballast is testedand matched with capacitors toprovide full lamp wattage atlower energy consumption.Ballast and capacitor are heatsunk for cool operation and longlife. Holophane ballasts ensurerated lamp output (ballast factor= 1.0)

• Easy attachment of reflector tohousing is provided by lockinglugs which prevent accidentaldislodging of the reflector.

• Optional quick disconnect orthroughway wiring chamberquickly spins onto .75” NPTconduit or can be ceiling mount-ed. Integral hinge supports forhands-free wiring. UL/CUL listed.Throughway box can carry up tofive #10 wires with 24 amps perwire.

Page 7: Appendix B: Lighting Calculations & Specifications

6

PRISMALUME®

HOLOPHANE®

Page 8: Appendix B: Lighting Calculations & Specifications

“31”

“35”“37” “39”

“40” “50”

PRISMALUME®

7 HOLOPHANE®

A choice of light distributions

Reflector catalog number matrix

High Pressure Sodium - Lamp source and wattageSpacing to 150HP 150HP 250HP 250HP 400HP 400HP 400RHP 400RHP 750HP 1000CHP 1000HPmtg. ht. ratio Clear Diffuse Clear Diffuse Clear Diffuse Clear Diffuse Clear Clear Clear0.7:1 Z400.8:1 B390.9:1 N39 M39 J39 Z391.0:1 S401.1:1 N39/S40 Z31 S40 U401.2:1 M35 M35 M35 M39 J39 H401.3:1 Q40 J39/L501.4:1 J31 T50 R50 Q50 W391.5:1 H31 M37 G351.6:1 H31 Z31/M35 M35 J35 S39 L391.7:1 N31 S40 P31 U40 C35/H391.8:1 J31 N31/M35 P31/R50 N311.8:1 T50 J351.9:1 M37 M37 J37 M352.0:1 H31 H31/M37 L31 L31/J37 V502.2:1 U39

Metal Halide - Lamp source and wattageSpacing to 250MP/250PPmtg. ht. ratio 25LMP/25LPP 350PM/35LPM

175MP 320PP 400PM/40LPM 400MH 400MH 400SMH 400SMH 400RMH 400RMH 750PM 1000MH 1000MHClear Clear Clear Clear Coated Clear Coated Clear Coated Clear Clear Coated

0.7:1 E40 M400.8:1 E40 E40 E40 M400.9:1 E40 Z40 B501.0:1 L40 G39 Z39 B40/B501.1:1 B35 B35 B35 B35/G39 B35 Y31/L50 Y35 B40 B39

H50 Z391.2:1 M35 M35 H50 G39/H50 G39 H50 L50 Z39 Y50 Y501.3:1 L39 H50 E31/B37 M31/Y37 N39

M39 J39 T501.4:1 B37/M39 M39 J391.5:1 J31/M37 J31/M37 B37 B37/M39 E31 N39 P39 C31/E351.6:1 E31 E31 N39 E31/B37 M31/Y37 B391.8:1 N39 N39 N39 P39

Page 9: Appendix B: Lighting Calculations & Specifications

8

PRISMALUME®

HOLOPHANE®

Photometric Data — High Pressure Sodium

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

TOTALEFFIC.

OUTPUT DATA

60°60°

90° 90°

120° 120°180°150° 150°

39518

2500 CD/DIV

0 .98 .98 .98 .81 .81 .81 .701 .86 .83 .80 .71 .69 .68 .592 .76 .71 .67 .64 .61 .58 .513 .68 .62 .57 .57 .53 .50 .444 .61 .54 .49 .51 .47 .43 .385 .54 .48 .43 .46 .42 .38 .346 .49 .42 .37 .42 .37 .34 .307 .45 .38 .33 .38 .33 .30 .268 .41 .34 .29 .35 .30 .27 .239 .37 .31 .26 .32 .27 .24 .21 .34 .28 .23 .30 .25 .21 .19

ZONALDEGREES

TEST OF HOLOPHANE PRSL400HPXXPDM35

POSITION OF LAMP Set Position

LAMP 400W Clear HPS LUMENS 50000

WATTS 400 BULB TYPE E-18

TEST DISTANCE 25 ft S.C. = 1.6

TESTED BY

TEST NO.

pfcpccpw

20%70% 30%50% 30% 10% 50% 30% 10% 0%

RC

R

0°30° 30°

0 98035 9567 913

10 974815 10232 290020 10786

25 12005 555730 1473835 16216 1018740 1418545 10251 7939

50 624655 3342 299865 1344 133470 1419

75 1444 152880 150385 1511 164890 150195 1604 1750

105 2008 2124115 2125 2109125 1939 1740135 1457 1128145 1231 773

155 906 419165 159 45175 167 16180 207

0-30 9370 18.730-60 21124 42.260-90 4510 9.0

0-90 35004 70.090-180 10105 20.20-180 45109 90.2

CERTIFIED BY

10

20%70% 30%50% 30% 10% 50% 30% 10% 0%

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

OUTPUT DATATEST OF HOLOPHANE PRSL400HP00XXN31

POSITION OF LAMP Set Position

LAMP 400W Clear HPS LUMENS 50000

WATTS 400 BULB TYPE E-18

TEST DISTANCE 25 ft S.C. = 1.7

TESTED BY CERTIFIED BY

TEST NO.

pfc

pccpw

RC

R

0 .98 .98 .98 .82 .82 .82 .721 .85 .81 .78 .71 .69 .67 .592 .74 .69 .64 .63 .59 .56 .493 .65 .59 .54 .55 .51 .47 .424 .58 .51 .45 .49 .44 .41 .365 .52 .44 .39 .44 .39 .35 .316 .46 .39 .34 .40 .35 .31 .277 .42 .35 .30 .36 .31 .27 .238 .38 .31 .26 .33 .28 .24 .219 .34 .28 .23 .30 .25 .21 .18

.32 .25 .21 .28 .22 .19 .16

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150° 0 91225 9321 890

10 908415 9357 265220 9330

25 9636 446030 1084235 12450 782140 1306445 11226 8694

50 814055 5507 494060 364065 2570 255170 2157

75 1892 200180 178485 1669 182190 148395 1526 1665

105 1601 1694115 1594 1582125 1453 1303135 1365 1057145 1395 877

155 1059 490165 305 86175 236 22180 167

0-30 8002 16.030-60 21455 42.960-90 6373 12.7

0-90 35831 71.790-180 8777 17.60-180 44607 89.2

40964

2000 CD/DIV

10

0 1.00 1.00 1.00 .84 .84 .84 .731 .85 .81 .78 .72 .69 .67 .592 .74 .68 .63 .62 .58 .55 .483 .64 .57 .52 .54 .49 .45 .404 .56 .49 .43 .48 .42 .38 .335 .50 .42 .36 .42 .37 .32 .286 .44 .36 .31 .38 .32 .28 .247 .40 .32 .27 .34 .28 .24 .208 .36 .28 .23 .30 .25 .21 .189 .32 .25 .20 .28 .22 .18 .1510 .29 .23 .18 .25 .20 .16 .13

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

OUTPUT DATATEST OF HOLOPHANE PRSL400HPXXH31

POSITION OF LAMP Set Position

LAMP 400W Clear HPS LUMENS 50,000

WATTS 400 BULB TYPE E-18

TEST DISTANCE 25 ft S.C. 2.0

TESTED BY

TEST NO.

pfcpccpw

RC

R

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150°

40948

2000 CD/DIV

CERTIFIED BY

20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%

5576 5828 5704 6258 6913

7698 8893106321247112277

10139 7185 5115 3525 2696

2353 2117 1941 1744 1686

1648 1656 1461 1229 1110

987 281 227 163

556

1774

3563

6679

9508

6446

3499

2490

2117

1839

174416431311951698

457 80 22

589322633 810636632 874445376

11.845.316.273.317.590.8

0 5101520

2530354045

5055606570

7580859095

105115125135145

155165175180

0-30 30-60 60-90 0-9090-180 0-180

20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PRSL400HPXXPDS40

POSITION OF LAMP Set Position

LAMP 400W Clear HPS LUMENS 50000

WATTS 400 BULB TYPE E-18

TEST DISTANCE 25 ft S.C. = 1.1

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

RC

R

0 .99 .99 .99 .80 .80 .80 .691 .85 .82 .79 .70 .68 .66 .562 .76 .70 .66 .62 .59 .56 .483 .68 .61 .56 .56 .52 .49 .424 .61 .54 .49 .51 .46 .43 .375 .55 .48 .43 .46 .42 .38 .336 .50 .43 .38 .43 .38 .34 .307 .46 .39 .34 .39 .35 .31 .278 .42 .36 .31 .36 .32 .28 .259 .39 .33 .28 .34 .29 .26 .23

.36 .30 .26 .32 .27 .24 .21

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150° 0 156505 14178 1353

10 1521615 17386 492820 16879

25 16089 744730 1362435 10451 656540 685445 4805 3721

50 452955 4406 395260 314265 1903 188970 1599

75 1975 208980 227185 2440 266290 229695 2171 2369

105 1973 2087115 2353 2335125 2689 2413135 1947 1508145 856 538

155 702 325165 276 78175 307 29180 548

0-30 13729 27.530-60 14239 28.560-90 6641 13.3

0-90 34608 69.290-180 11682 23.40-180 46290 92.6

39663

2000 CD/DIV

10

20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PSCP1HP00XXC35

POSITION OF LAMP Set Position

LAMP 1000W COMPACT HPS LUMENS 125,000

WATTS 1000 BULB TYPE ED-37

TEST DISTANCE 25 ft S.C. 1.7

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

RC

R

0 .97 .97 .97 .79 .79 .79 .681 .83 .79 .76 .68 .66 .64 .552 .72 .67 .62 .60 .56 .53 .463 .64 .57 .52 .53 .49 .45 .394 .57 .50 .44 .47 .42 .39 .335 .51 .43 .38 .42 .37 .33 .296 .45 .38 .33 .38 .33 .29 .257 .41 .34 .29 .35 .29 .26 .228 .37 .30 .26 .32 .26 .23 .199 .34 .27 .23 .29 .24 .20 .1710 .31 .25 .20 .27 .22 .18 .15

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150°

45525

5000 CD/DIV

0 5101520

2530354045

5055606570

7580859095

105115125135145

155165175180

1808118694188052074823118

2501828060311232879723891

1714311272 7271 5499 5450

5414 5679 5814 5330 5351

5448 5358 4906 3767 2624

2516 548 345 297

1784

5881

11580

19551

18502

10113

5458

5728

6343

5838

5764 5319 4401 2917 1648

1165 155 33

19246 48166 17529 84941 27241112182

15.438.514.068.021.889.7

0-30 30-60 60-90 0-9090-180 0-180

20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PSC10HP00XXC35

POSITION OF LAMP Set Position

LAMP 1000W Clear HPS LUMENS 140,000

WATTS 1000 BULB TYPE ED-25

TEST DISTANCE 25 ft S.C. .8

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

RC

R

0 .91 .91 .91 .73 .73 .73 .611 .78 .75 .72 .62 .60 .58 .492 .69 .63 .59 .55 .52 .49 .413 .61 .55 .50 .49 .45 .42 .354 .54 .48 .43 .44 .40 .36 .315 .49 .42 .37 .40 .36 .32 .276 .44 .38 .33 .37 .32 .29 .247 .41 .34 .30 .34 .29 .26 .228 .37 .31 .27 .31 .27 .23 .209 .34 .28 .24 .29 .25 .21 .1810 .32 .26 .22 .27 .23 .20 .17

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150°

45522

8000 CD/DIV

0 5101520

2530354045

5055606570

7580859095

105115125135145

155165175180

0-30 30-60 60-90 0-9090-180 0-180

5275749621439944049533828

2715121859199181809716704

1451511805 9639 7516 6247

5692 5965 6295 6090 6383

6633 6996 7391 5498 3971

2025 869 845 654

4737

11479

12567

12513

12936

10591

7461

6021

6868

6964

7017 6945 6631 4258 2495

937 246 81

28783 36040 20350 85172 35573120745

20.625.714.560.825.486.2

Page 10: Appendix B: Lighting Calculations & Specifications

PRISMALUME®

9 HOLOPHANE®

Photometric Data — Metal Halide

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PRSL400MH00XXE31

POSITION OF LAMP Set Position

LAMP 400W Clear MH LUMENS 36000

WATTS 400 BULB TYPE E-37

TEST DISTANCE 25 ft S.C. = 1.6

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

RC

R

0 .97 .97 .97 .81 .81 .81 .711 .84 .81 .78 .71 .69 .67 .592 .74 .69 .64 .62 .59 .56 .503 .65 .59 .54 .56 .51 .48 .424 .58 .51 .46 .50 .45 .41 .375 .52 .45 .40 .45 .40 .36 .326 .47 .40 .35 .40 .35 .31 .287 .42 .35 .30 .37 .32 .28 .248 .38 .32 .27 .33 .28 .25 .229 .35 .28 .24 .31 .26 .22 .19

.32 .26 .21 .28 .23 .20 .17

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150° 0 72225 6730 642

10 657515 6763 191720 7038

25 7481 346330 833035 9777 614240 1103445 8354 6470

50 475755 2655 238260 193365 1588 157670 1471

75 1358 143780 123085 1137 124190 98395 1033 1127

105 1221 1291115 1221 1212125 1040 933135 920 713145 1065 669

155 783 363165 219 62175 157 15180 119

0-30 6022 16.730-60 14993 41.660-90 4254 11.8

0-90 25269 70.290-180 6384 17.70-180 31653 87.9

40946

1500 CD/DIV

10

20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%

20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PRSL400MH00XXE31

POSITION OF LAMP Set Position

LAMP 400W Coated MH LUMENS 36,000

WATTS 400 BULB TYPE E-37

TEST DISTANCE 25 ft S.C. 1.5

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

RC

R

0 .96 .96 .96 .77 .77 .77 .651 .82 .78 .74 .65 .63 .61 .512 .71 .65 .61 .57 .54 .50 .423 .62 .56 .51 .50 .46 .43 .364 .55 .48 .43 .45 .40 .37 .315 .49 .42 .37 .40 .35 .32 .276 .45 .37 .32 .36 .32 .28 .237 .40 .33 .28 .33 .28 .24 .208 .37 .30 .25 .30 .25 .22 .189 .33 .27 .22 .28 .23 .19 .1610 .31 .24 .20 .26 .21 .18 .15

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150°

40947

5000 CD/DIV

0 5101520

2530354045

5055606570

7580859095

105115125135145

155165175180

0-30 30-60 60-90 0-9090-180 0-180

64656508648864986457

67157367763770875641

41303052246220581863

17231716166715821631

16871687161815021261

815 293 171 113

621

1842

3108

4798

4368

2738

2043

1822

1819

1780

1785167514521163 792

377 83 16

557111904 568423159 912332283

15.533.115.864.325.389.7

20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PRSL400MH00XXE31PS40RMH00XXM31 MAG. REG. BALLAST

POSITION OF LAMP Set Position

LAMP 400W Clear SMH LUMENS 40,000

WATTS 400 BULB TYPE BT-37

TEST DISTANCE 25 ft S.C. 1.6

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

RC

R

0 .96 .96 .96 .80 .80 .80 .691 .84 .80 .77 .70 .68 .66 .572 .74 .68 .64 .62 .58 .55 .483 .65 .59 .54 .55 .51 .47 .414 .58 .51 .46 .49 .44 .41 .365 .52 .45 .40 .44 .39 .35 .316 .47 .40 .35 .40 .35 .31 .277 .42 .35 .30 .36 .31 .27 .248 .38 .32 .27 .33 .28 .24 .219 .35 .28 .24 .30 .25 .22 .1910 .32 .26 .21 .28 .23 .20 .17

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150°

41001

2000 CD/DIV

0 5101520

2530354045

5055606570

7580859095

105115125135145

155165175180

0-30 30-60 60-90 0-9090-180 0-180

8937 7938 7424 7602 7798

8086 89051028511540 9293

5384 2850 1996 1607 1568

1468 1338 1246 1106 1178

1416 1444 1225 1132 1443

1681 259 173 132

758

2155

3743

6461

7197

2557

1595

1553

1359

1286

149814331099 877 907

778 73 16

665516214 450727376 796735343

16.640.511.368.419.988.4

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PRSL400MHXXPDB35

POSITION OF LAMP Set Position

LAMP 400W Clear MH LUMENS 36000

WATTS 400 BULB TYPE E-37

TEST DISTANCE 25 ft S.C. = 1.1

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

20%70%50% 30% 10% 50% 30% 10% 0%

30% 0

RC

R

0 .93 .93 .93 .76 .76 .76 .641 .82 .80 .77 .68 .66 .65 .562 .74 .70 .66 .62 .59 .57 .503 .67 .62 .58 .57 .53 .51 .454 .61 .56 .51 .52 .48 .46 .405 .56 .50 .46 .48 .44 .41 .376 .51 .46 .41 .44 .40 .37 .337 .47 .42 .37 .41 .37 .34 .318 .44 .38 .34 .38 .34 .31 .289 .41 .35 .31 .36 .32 .29 .26

.38 .32 .29 .33 .29 .26 .24

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150° 0 129985 12905 1232

10 1283615 12876 365020 12561

25 12532 580130 1435835 12164 764140 527645 1916 1484

50 116555 918 82460 84065 865 85870 894

75 852 90280 82385 800 87290 86495 1130 1233

105 1796 1900115 1571 1560125 725 650135 1235 956145 1671 1049

155 882 408165 96 27175 95 9180 118

0-30 10682 29.730-60 9949 27.660-90 2632 7.3

0-90 23264 64.690-180 7793 21.60-180 31057 86.3

39649

2000 CD/DIV

10

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PRSL400MHXXPDE40

POSITION OF LAMP Set Position

LAMP 400W Clear MH LUMENS 36000

WATTS 400 BULB TYPE E-37

TEST DISTANCE 25 ft S.C. = .8

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

20%70%50% 30% 10% 50% 30% 10% 0%

30% 0

RC

R

0 .97 .97 .97 .78 .78 .78 .671 .85 .82 .79 .69 .67 .66 .562 .76 .71 .67 .63 .60 .57 .503 .69 .63 .59 .58 .54 .51 .454 .63 .57 .52 .53 .49 .46 .415 .58 .52 .47 .49 .45 .42 .386 .54 .47 .43 .46 .42 .39 .357 .50 .44 .39 .43 .39 .36 .328 .46 .41 .36 .41 .37 .33 .309 .44 .38 .34 .38 .34 .31 .28

.41 .35 .32 .36 .32 .29 .27

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150° 0 243615 23347 2229

10 2238115 21353 605320 16255

25 11805 546430 667135 3835 240940 296245 2905 2249

50 303455 2317 207960 88065 1099 109170 1215

75 1354 143280 144185 1368 149390 117995 1177 1284

105 1391 1471115 1990 1976125 2148 1927135 1019 789145 715 449

155 899 416165 204 58175 203 19180 303

0-30 13745 38.230-60 6737 18.760-90 4016 11.20-90 24499 68.1

90-180 8390 23.30-180 32888 91.4

39625

4000 CD/DIV

10

20%70% 30% 0%50% 30% 10% 50% 30% 10% 0%

PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055

DISTRIBUTION DATA

ANGLEDEGREES

CANDLEPOWER

LUMENS

ZONALLUMENS

ZONALDEGREES

TOTALEFFIC.

O U T P U T D ATATEST OF HOLOPHANE PSC10MH00XXB40

POSITION OF LAMP Set Position

LAMP 1000W Clear MH LUMENS 110,000

WATTS 1000 BULB TYPE BT-56

TEST DISTANCE 25 ft S.C. 1.1

TESTED BY CERTIFIED BY

TEST NO.

pfcpccpw

RC

R

0 1.00 1.00 1.00 .81 .81 .81 .681 .87 .83 .80 .70 .68 .66 .562 .77 .71 .67 .62 .59 .56 .483 .69 .62 .57 .56 .52 .49 .424 .62 .50 .50 .51 .47 .43 .375 .56 .49 .44 .47 .42 .38 .336 .51 .44 .39 .43 .38 .34 .307 .47 .40 .35 .39 .35 .31 .278 .43 .36 .32 .36 .32 .28 .249 .40 .33 .29 .34 .29 .26 .2210 .37 .30 .26 .32 .27 .24 .21

0°30° 30°

60°60°

90° 90°

120° 120°180°150° 150°

45329

6000 CD/DIV

0 5101520

2530354045

5055606570

7580859095

105115125135145

155165175180

0-30 30-60 60-90 0-9090-180 0-180

3223531857331603693837363

3513329600219591515511884

10362 8606 6394 3696 4013

4248 4668 5042 4756 4693

4454 5059 6573 6630 2890

2375 739 599 693

3041

10471

16262

13795

9203

7721

3669

4494

5501

5120

4711 5021 5897 5135 1815

1099 209 57

29774 30720 13664 74157 29066103223

27.127.912.467.426.493.8

Page 11: Appendix B: Lighting Calculations & Specifications

10

PRISMALUME®

HOLOPHANE®

Complete luminaire shall be Holophane catalog

number ________. The luminaire shall consist of

two sub-assemblies: ballast assembly containing the

electrical components, mounting hardware and

reflector attachment lugs; and optical reflector. It

shall have passed .5g accelerated fatigue vibration

test, high ambient temperature test of _________,

and provide for lamp starting in -20°F (MH/MV),

-40°F (HPS) ambients.

The complete luminaire shall be UL listed to US and

Canadian safety standards, Inc. as suitable for use in

damp location ambients of up to 55°C as standard,

65°C optional.

The die cast aluminum ballast housing shall be

protected against corrosion by a seven stage pre-

treatment process followed by a sprayed on white

polyester powder paint, cured and baked on at

218°C; which exceeds ASTM standard practice for

hardness, humidity, impact and salt spray resistance

to prevent cross hatch creep, fading, cracking, and

other corrosion related deterioration.

The pre-wired, porcelain enclosed lamp holder with

corrosion resistant, nickel plated lamp grip screw

shell, shall be factory set for optimum distribution.

The zinc plated steel, reflector attachment yoke shall

have swingover locking lugs and provision for full

ventilation and optional safety chain. No tools shall

be required to attach or detach the reflector from

the housing while installed.

Optional Mounting Methods (Choose One)

(See pg. 15 for C/UL/US temperature listings)

P/PD - Pendant

The separable .75” NPT threaded conduit

mounting plate with integral set screw shall

provide quick install unidirectional luminaire slide

on attachment. Housing shall be balanced and

suitable for support from hooks or loops without

field adjustment.

Wireway cover shall enclose the fast splice wiring

chamber which is suitable for 90° supply wire.

N/ND - Non-Disconnect Pendant and

Throughway Wiring

The die cast aluminum pendant and/or

throughway integral wiring box shall contain

provisions for both .75” NPT conduit and direct

ceiling mounting. It shall contain an integral

hinge which connects with the die cast

aluminum pin on the housing to support the

luminaire while electrical splices are made. It

shall have the same corrosion resistant finish as

the housing. It shall have 2 cast in side

knockouts, 4 ceiling mount drill points, .75” NPT

conduit threaded top opening, and be C/UL/US

certified for up to five #10 AWG conductors for

through wiring.

The housing shall swing up and connect to the ND

box by latching the captive J bolt and wing nut

without use of tools.

Q/QD - Quick-Disconnect Pendant and

Throughway Wiring

The die cast aluminum pendant and/or

throughway quick disconnect wiring box shall

contain provisions for both .75” NPT conduit and

direct ceiling mounting. It shall contain an

integral hinge which connects with the die cast

aluminum or stainless steel hinge pin on the

housing to allow the luminaire to hang free with

electrical disconnect. It shall have the same cor-

rosion resistant finish as the housing. It shall

have 2 cast in side knockouts, 4 ceiling mount

drill points, .75” NPT conduit threaded top

opening, and be capable of carrying up to five

#10 AWG conductors for through wiring.

The housing shall swing up and connect to the QD

box by latching the captive J bolt and wing nut

without use of tools.

A dead front female receptacle shall be mounted

inside the QD box which will make an electrical

connection with the pre-wired male plug on the

housing.

The receptacle shall be C/UL/US for connection to

lighting branch circuits which can then be energized

before the housing is attached. The grounding

connection shall be the first to make contact and the

last to disconnect.

It shall be C/UL/US listed per UL-1059 (Panel Board

Accessory) and UL-98 (Enclosed and Dead Front

Switches) permitting the fixture to be disconnected

while under load.

PF - Mounting Hooks and Loops

Mounting hooks and loops shall be lubricating

malleable cast iron and protected against corrosion

with zinc plated yellow chromate finish.

Optical Assembly

Glass reflector shall be Endural® prismatic borosil-

icate glass with a minimum wall thickness of

3mm (.13"). Reflector shall be supported by

three 5mm (.19”) min. dia. steel rods bolted to a

bottom retaining ring made of concentric rings of

6mm (.22”) min. dia. steel rod.

When tested with a ________ watt ________ lamp,

zonal outputs shall be not less than:

Zonal %total

degrees lamp

lumens

0 - 30 ______________________

30 - 60 ______________________

60 - 90 ______________________

0 - 90 ______________________

90 - 180 ______________________

Luminaire shall have a spacing criteria of ________.

The physical properties of the Holophane Prismalume® Seriesluminaires represent typical average values obtained inaccordance with accepted test methods and are subject tonormal manufacturing variations. They are supplied as atechnical service and are subject to change without notice.Check with your local Holophane sales representative toassure current information.

Performance Specification

Page 12: Appendix B: Lighting Calculations & Specifications

PRISMALUME®

11 HOLOPHANE®

Retail Applications

Page 13: Appendix B: Lighting Calculations & Specifications

12

PRISMALUME®

HOLOPHANE®

Sports Facilities

Page 14: Appendix B: Lighting Calculations & Specifications

How to construct a catalog number for Prismalume Fixture type___________

EXAMPLE: PRSL — 400HP —12 — PD — M35 — F1 Fill in — — — — — 1 2 3 4 5 6 cat. no.: 1 2 3 4 5 6

Catalog no. Description

1 Luminaire__ PRSL Prismalume__ PS Prismalume

2 Source and wattagePRSL__ 15AHP 150W/55V HPS__ 25LHP 250W HPS, energy saving ballast__ 250HP 250W HPS__ 40LHP 400W HPS, energy saving ballast__ 400HP 400W HPS__ 175MP1 175W MH, protected lamp__ 250MP1 250W MH, protected lamp__ 250PP1 250W MH, pulse start, protected lamp__ 25LMP1 250W MH, protected lamp, energy saving ballast__ 25LPP1 250W MH, pulse start, protected lamp, energy saving ballast__ 320PP1 320W MH, pulse start, protected lamp__ 350PM 350W MH, pulse start__ 35LPM 350W MH, pulse start, energy saving ballast__ 400MH 400W MH __ 40LMH 400W MH, energy saving ballast__ 400PM 400W MH, pulse start__ 40LPM 400W MH, pulse start, energy saving ballastPS__ 750HP 750W HPS (not available with MT, VT)__ 750PM 750W MH, pulse start__ CP1HP 1000W HPS, compact lamp__ C10HP 1000W HPS__ 40RMH 400W MH, Mag Reg (not available with MT, VT)__ C10MH 1000W MH

3 Voltage__ 12 120 volt__ 20 208 volt__ 24 240 volt__ 27 277 volt__ 34 347 volt__ 48 480 volt__ MT Multi-voltage (120 - 277V USA)__ VT Vari-tap (120, 277, 347V Canada and 250HP, 400HP, 400MH only)

4 MountingPRSL PS__ PD __ P Pendant mount for .75” NPT conduit__ QD __ Q Quick disconnect power hanger for pendant and thru-way wiring. Not available with “CDP”, “PHCB” or “PF”.__ ND __ N No quick disconnect power hanger for pendant and thru-way wiring

5 OpticsSelect reflector catalog no. from matrix on page 7 for desired spacing and wattage

6 Options and AccessoriesSee pages 14 and 15 for available options and accessories.

Note: 1 These fixtures use sockets that accept open fixture rated lamps only. Standard mogul base lamps are not compatible.

Order number____________ Job name______________

PRISMALUME®

13 HOLOPHANE®

Ordering Data

Drawing #1Diameter PD QD, ND

Optics Reflector mm (in.) mm (in.) mm (in.)31 PRSL31 400 (15.90) 640 (25.15) 700 (27.55)35 PRSL35A 400 (15.90) 640 (25.15) 700 (27.55)37 PRSL37 410 (16.15) 610 (24) 670 (26.40)39 PRSL39 480 (18.90) 630 (24.55) 690 (26.95)40 PRSL40 560 (21.90) 630 (24.55) 690 (26.95)50 PRSL50 690 (26.95) 780 (30.65) 840 (33.05)

Drawing #2Diameter P Q, N

Optics Reflector mm (in.) mm (in.) mm (in.)31 PRSL31 400 (15.90) 710 (28.10) 770 (30.50)35 PRSL35A 400 (15.90) 710 (28.10) 770 (30.50)37 PRSL37 410 (16.15) 680 (26.60) 740 (29)39 PRSL39 480 (18.90) 700 (27.55) 760 (29.95)40 PRSL40 560 (21.90) 700 (27.55) 760 (29.95)50 PRSL50 690 (26.95) 850 (33.60) 910 (36)

QD,ND

PD

Dia.Drawing #1 — 150-400W

Q, N

P

Dia.

Drawing #2Mag reg, 750 and 1000W

PRSL PS

Page 15: Appendix B: Lighting Calculations & Specifications

14

PRISMALUME®

HOLOPHANE®

Options

Catalognumber Description

Options (Factory installed)__ F1 Single fuse assembly for 120, 240, 277, 347V. NA with “MT” or “VT”__ F2 Double fuse assembly for 208, 240, 480V. NA with “MT” or “VT”__ PF-105 Loop, malleable iron .75” NPT male; all fixtures except “Q”,“QD”__ PF-121 Safety hook, malleable iron .75” NPT male; all fixtures except “Q”,“QD”__ PF-129 Anti-rotational hook, malleable iron .75” NPT male; all fixtures except “Q”,“QD”__ PF-291 Universal gasketed hook assembly malleable iron .75” NPT male__ 65 For use in 65°C ambients (available for 40LMH, 40LPM, 40LHP, C10HP, C10MH only)__ CDP-L5-15-X (120V) 120V three foot, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ CDP-L6-15-X (208/240V) 208/240V, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ CDP-L7-15-X (277V) 277V, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ CDP-L24-20-X (347V) 347V, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ CDP-L8-20-X (480V) 480V, three conductor cord and NEMA plug (order “PF” also) (X = No. of feet. 3 feet is standard)__ EM1 Standby lighting fixture uses a D.C. bayonet base, 250W (max.) tungsten halogen lamp (included) to provide standby lighting. (Not

available with 750HP, 277 or 480V)__ ER1 Emergency lighting fixture less relay for use with a 120 volt external power source to operate a D.C. 250W (max.) bayonet base tungsten

halogen lamp (included) to provide emergency lighting. (All fixtures except “CDP”, “PHCB”, “Q” or “QD”.) (Includes Tee condulet). NotCSA certified

__ TD1 Standby lighting fixture. Appropriate halogen-tungsten lamp and Time Delay relay are supplied with fixture. Not available with “EM”,“ER” or “65”. Limited to 40°C ambient.

__ PS HPS protected starter__ PHCB (120, 208, 240, 277, 347V) Power-hook cord, special configuration plug cap and “PF-105” loop attached (use with “UPH-35” or “UPH-36”); all fixtures except

“MT”, “-ER”, “Q” or “QD”__ PHCB-L8-480 (480V) Power-hook cord, special configuration plug cap and “PF-105” loop attached (use with “UPH-35-L8-480” or “UPH-36-L8-480” on 480

volt units only); all fixtures except “-ER”, “Q”, or “QD”__ H HALT® Automatic lamp time-out. Available on MH or PM units only. Not available on units with Pulse Metal Halide in combination with

“EM”, use TD instead. MT or VT available through TSG. Customer specifies voltages to be wired. 55°C max.__ D35 AERS®- Automatic Energy Reduction System low voltage DC control handled through TSG. DC control module, sensors, and Holoflex® must

be specified through TSG. 40°C listed. Available with 250HP, 25LHP, 400HP, 40LHP. Not available with “QD”, “CDP”, “PHCB”, or “EM”.__ D50 AERS®- Automatic Energy Reduction System low voltage DC control handled through TSG. DC control module, sensors, and Holoflex®

must be specified through TSG. 40°C listed. Available with 15AHP, 175MP, 250HP, 25LHP, 250MP, 25LMP, 250PP, 25LPP, 320PP, 350PM,35LPM, 400HP, 40LHP, 400MH, 40LMH, 400PM, 40LPM. Not available with “QD”, “CDP”, or “PHCB”.

__ A35 AERS®- Automatic Energy Reduction System line voltage AC control handled through TSG. AC control module, sensors, and Holoflex® mustbe specified through TSG. 40°C listed. Available with 250HP, 25LHP, 400HP, 40LHP. Not available with “QD”, “CDP”, “PHCB”, or “EM”.

__ A50 AERS®- Automatic Energy Reduction System low voltage AC control handled through TSG. AC control module, sensors, and Holoflex®

must be specified through TSG. 40°C listed. Available with 15AHP, 175MP, 250HP, 25LHP, 250MP, 25LMP, 250PP, 25LPP, 320PP, 350PM,35LPM, 400HP, 40LHP, 400MH, 40LMH, 400PM, 40LPM. Not available with “QD”, “CDP”, or “PHCB”.

__ HFW Holoflex® flexible wiring system__ CR Extra heavy duty corrosion resistant finish__ 08214-3 Chain, .92m (3’)

Note: 1 See page 17 for a further description of “EM”, “TD” and “ER”.

UPH-35

PHCB Power-hook

Ballast housing

Thru-way UPH-35 Mounting Detail UPH-35 Pendant UPH-36

88mm (.31”) x 10mm (.38”)ceiling mounting (2) places

110mm(4.31”)

DN20NPT (.75”)threaded entry

22mm (.88”)

(2) wiring accesscovers

(2) KO’s forDN20 (.75”)conduit

120mm(4.88”)

130mm(4.94”)

30mm(1.06”)

110mm(4.5”)

Page 16: Appendix B: Lighting Calculations & Specifications

PRISMALUME®

15 HOLOPHANE®

Accessories

Ambient Temperature C/UL/US Listing Mounting OptionN, ND (Non-Disconnect) Q, QD (Quick Disconnect)

Lamp Wattage, Ballast Type P, PD Through No Through Through No Through(Pendant) Wiring Wiring Wiring

WiringMetal Halide, 90°C Building Wire400W Peak Lead 55°C 55°C 55°C 55°C 55°C400W EM, Peak Lead 55°C 55°C 55°C 55°C 55°C400W Mag Reg 55°C 55°C 55°C 55°C 55°C400W EM, Mag Reg 40°C 40°C 40°C 40°C 40°C1000W Peak Lead 55°C 55°C 55°C 55°C 55°C1000W EM, Peak Lead 55°C 55°C 55°C 55°C 55°CMetal Halide, 105°C Building Wire1000W 65°C Option, Peak Lead 65°C N/A 65°C N/A 65°CHigh Pressure Sodium, 90°C Building Wire400W Lead 55°C 55°C 55°C 55°C 55°C400W EM, Lead 55°C 55°C 55°C 55°C 55°C400W Mag Reg 55°C 55°C 55°C 55°C 55°C400W EM, Mag Reg 40°C 40°C 40°C 40°C 40°C750W Lead 55°C 55°C 55°C 55°C 55°C750W EM Lead (120, 208, 240 Only) 55°C 55°C 55°C 55°C 55°C1000W Lead 55°C 55°C 55°C 55°C 55°C1000W EM, Lead 55°C 55°C 55°C 55°C 55°C1000W Compact Lamp, Lead N/A N/A N/A N/A 55°C1000W EM, Compact Lamp Lead N/A N/A N/A N/A 55°CHigh Pressure Sodium, 105°C Building Wire1000W 65°C Option, Lead 65°C N/A 65°C N/A 65°C1000W Compact Lamp, Lead 55°C N/A 55°C N/A See 90°C Wire

Catalog number DescriptionAccessories (shipped separately)

__ LAMP Appropriate HID lamp supplied with fixtures__ PF-105-B Loop, malleable iron .75” NPT male; not available with “Q”,“QD”__ PF-116-A Loop, malleable iron .75” NPT female; not available with “Q”,“QD”__ PF-121-A Safety hook, malleable iron .75” NPT male: not available with “Q”,“QD”__ PF-122-A Safety hook, malleable iron .75” NPT female; not available with “Q”,“QD”__ PF-129-A Anti-rotational hook, malleable iron .75” NPT male: not available with “Q”,“QD”__ PF-291 Universal gasketed hook assembly malleable iron .75” NPT male__ UPH-35-XXX-WH Thru-way power-hook (order “PHCB” with fixture); not available with “MT”, “VT”, “-ER”, “Q” or “QD”. Insert voltage for XXX.

(120, 208, 240, 277, 347V)__ UPH-35-L8-480-WH Thru-way power-hook (order “PHCB-L8-480” with fixture); not available with“-ER”, “Q” or “QD” __ UPH-36-XXX-WH Pendant power-hook (order “PHCB” with fixture); not available with “MT”, “VT”, “-ER”, “Q” or “QD”. Insert voltage for XXX.

(120, 208, 240, 277, 347V)__ UPH-36-L8-480-WH (480V) Pendant power-hook (order “PHCB-L8-480” with fixture); not available with “-ER”, “Q” or “QD” __ WG-212-A Wire guard for open bottom PRSL35A and PRSL31 only__ WG-212-B Wire guard with relamping hole for open bottom PRSL35A and PRSL31 only __ WG-219-A Wire guard for open bottom PRSL37 only __ WG-219-B Wire guard with relamping hole for open bottom PRSL37 only __ GD-45 Wire guard with relamping hole for open bottom PRSL39 only

57mm(2.25”)

PF-105-BMalleable ironLoop.75” NPT male

PF-129-AMalleable ironAnti-rotational hook.75” NPT male

73mm(2.88”)

67mm(2.63”)

71mm(2.78”)

92mm(3.62”)

45mm(1.75”)

PF-121-AMalleable ironSafety hook, .75” NPT male

PF-116-AMalleable ironLoop.75” NPT female

PF-122-AMalleable ironSafety hook, .75” NPT female

PF-291Malleable ironSafety hook,.75” NPT male

Page 17: Appendix B: Lighting Calculations & Specifications

Holoflex

Fusing

16

PRISMALUME®

HOLOPHANE®

Fusing and Holoflex® Options

ND Mount fuse option: in linefuses are available for fieldinstallation

PD Mount fuse option: fuseholder attaches to splice box coveras shown.

QD Mount fuse option: fuseholder is standard.

QD Fuse holder: is available assingle fuse “F1” for 120, 240,277 and 347V; double fuse“F2” available for 208, 240 and480V.

PD Mount single fuseassembly “F1”: available for120, 240, 277 or 347V.

PD Mount double fuseassembly “F2”: available for208, 240 or 480V

HFW - Lighting “L” cord drop

Three circuit power distributionDistribution Box Cable

Extender CableLighting Fixture Drop

Distribution Box Cable

Home Run Cable

Lighting Panel

ND Mount fuse option

PD Mount fuse option

QD Mount fuse option PD Mount double fuse assembly

PD Mount single fuse assembly

QD Fuse holder

Holoflex® wiring

A modular single or three phasewiring system that providesflexibility in layout, quick installa-tion and lower installed cost.

Holoflex® system benefits

• Labor saving installation

• Flexibility; fixtures may be easilyrelocated without costlyelectrical system modifications

• Replaces power-hook and cordassemblies

• Ease of maintenance

• Possible tax advantages

• For additional information onHoloflex, see brochure HL-992

Page 18: Appendix B: Lighting Calculations & Specifications

HALT®

EM, TD, ER

PRISMALUME®

17 HOLOPHANE®

Standby, Emergency and HALT™ Options

UL 1598 listed standby lightsystems

EM: When an HID lamp isextinguished due to a momentarypower interruption, and power isimmediately restored, an internalrelay energizes a tungsten halogenlamp (QCL/DC) until the HID lamprestrikes, at which time thetungsten halogen lamp switchesoff.

TD: When power is supplied orrestored to the fixture, an internalrelay energizes a tungsten/halogenlamp. The tungsten/halogen lampremains energized for a periodduring and following the HID lamprestrike as the HID lamp energizes.Following the delay period thetungsten/halogen lamp turns offprior to the HID lamp reaching fullluminance.

HALT® — Holophane Auto-matic Lamp Time-out (patentpending)

H: Designed for metal halidefixtures operating 24 hours perday, 7 days per week, the HALTdevice will extinguish the individualluminaire’s lamp for 15 minutes,once per week at random times,complying with lamp manufac-turers’ turn-off recommendations.HALT reduces the potential fornon-passive end of life lamp failurewhile eliminating the inconven-ience of manual or time controlswitching. For additional informa-tion see Holophane brochure HL-1926.

UL 924 listed emergencyfixture

ER: When an HID lamp isextinguished due to a powerfailure, 120V auxiliary power maybe supplied directly to a tungstenhalogen lamp. Tee condulet in-cluded. Not CSA certified.

HALT device insideballast housing.

Page 19: Appendix B: Lighting Calculations & Specifications

AERS® — Low voltage control wiring

Sensor Locations

Control Module

12 Volt or 24 Volt Low VoltageDC Control Wiring(Class II)

Line Voltage Feeds

18

PRISMALUME®

HOLOPHANE®

AERS® Options

AERS® luminaire

The standard Holophane lumin-aire is designed with a modifiedballast and relay. The modifiedballast is designed to operate thelamp at two input wattages: HPS,normal input like a standardluminaire, and a reduced inputeither 35% or 50% of full input;and metal halide, normal inputand a reduced input of 50%. Therelay is wired to an occupancysensor (or some type of contactclosure) through a control moduleallowing the luminaire to switchbetween the two input wattages.The relay signals the ballast whichinput wattage to supply the lampat any time.

Low voltage control

The AERS system can be installedseparately from the main powerdistribution using low voltage DCcontrol wiring. Each controlmodule is designed to handle up

AERS® — AC Power control wiring

Holoflex® Power Distributionwith AERS® Control

AERS® — AC Holoflex®

Control Module

Conduit

Distribution Panel

Zone 1

Zone 2

Zone 3

For additional information see HL-1161

Sensor Locations

to six zones. This system is idealfor adding AERS control to installa-tions with existing power distribu-tion.

Line voltage control

AERS is also available using linevoltage control wiring. Line powerand control wiring can runtogether through the same con-duit. (Not available with Q, QDH,CDP or PHCB).

Line voltage/ Holoflex control

Holophane has incorporatedAERS® into its Holoflex flexiblewiring system. Line power andcontrol wiring are fed through asingle cable. The AERS controlmodule is designed to handle upto three zones. This system is idealfor installing AERS into new instal-lations.

Page 20: Appendix B: Lighting Calculations & Specifications

PRISMALUME®

19 HOLOPHANE®

This installation photo demon-strates the effect of HolophanePrismalume luminaires withprismatic glass reflectors in amanufacturing environment.Prismalume luminaires illuminatethe left half of this productionfacility. The right half of the photoillustrates the inadequate lightingfrom aluminum reflector unitsoriginally used in this application.Prismalume’s prismatic glass opticsdeliver improved horizontal andvertical illumination. Additionally,the uplight component from thePrismalume luminaires illuminatesthe ceiling space, eliminating the“cavern effect”. Workers exper-ience increased visual comfortand less eyestrain, resulting inincreased productivity.

Prismalume Glass Aluminum Reflector

Page 21: Appendix B: Lighting Calculations & Specifications

HL-755 8/02 ©2002 Acuity Brands, Inc Printed in USA

Acuity Lighting Group, Inc.

214 Oakwood Ave., Newark, OH 43055 /Holophane Canada, Inc. 9040 Leslie Street, Suite208, Richmond Hill, ON L4B 3M4 / HolophaneEurope Limited, Bond Ave., Milton Keynes MK11JG, England / Holophane, S.A. de C.V.,Apartado Postal No. 986, Naucalpan de Juarez,53000 Edo. de Mexico

Contact your local Holophane factory salesrepresentative for application assistance, andcomputer-aided design and cost studies. Forinformation on other Holophane products andsystems, call the Inside Sales Service Departmentat 740-345-9631. In Canada call 905-707-5830 or fax 905-707-5695.

Limited Warranty and Limitation of LiabilityRefer to the Holophane limited materialwarranty and limitation of liability on thisproduct, which are published in the “Terms andConditions” section of the current productdigest, and is available from our local Holophanesales representative.

Visit our web site at www.holophane.com