1
newsletter 01/14-7 1 2 5 3 4 Axtrocare GmbH Wiesenstr. 1 D-78166 Donaueschingen Fon: +49 (0) 771 - 204.64.90 www.axtrocare.com Fax: +49 (0)771-204.64.89 [email protected] Uncomplicated use in gynecology Reusable and universal instrument to be used in colpotomy, LAVH or TLH. MyTube Good visualization of the uterine vessels for a safe dissection. Stable pneumoperitoneum during application. Ease of use, increases patient safety and allows a reduced operating time. Atraumatic instrument attachment ― In gynaecologic-anatomy adapted design Optimal sizes ― Reusable attachments in three sizes: 30, 40 and 50mm Simple reprocessing ― robust, biocompatible high per- formance plastic can be easily processed at 134 ° C / 3 bar Stable access ― One-way valve as a access for 10 mm instruments Lightweight ― solid, reusable guiding tube 02-00091 MyTube-colpotomy-set incl. set of valves: Guiding tube Ø 12 mm (ID) x 184 mm, reusable Attachment Ø 40 mm x 85 mm, reusable Attachment Ø 50 mm x 85 mm, reusable Valve-set Ø 10 mm, sterile for 1 single use, 1 piece / pack Set valve cover Ø 10 mm, sterile for 5 single uses, 5 pcs. / pack Optional: Attachment Ø 30 mm x 70 mm, reusable 02-00095 Ordering information 02-00087 02-00088 02-00089 02-00094 02-00090 Yours axtrocare-Team

AO NL 01-14-6 MyTube 2 de en it es

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

newsletter 01/14-7

1

2

5

34

Axtrocare GmbHWiesenstr. 1D-78166 DonaueschingenFon: +49 (0) 771 - 204.64.90www.axtrocare.com

Fax: +49 (0)[email protected]

Uncomplicated use in gynecology

Reusable and universal instrument to be used in colpotomy, LAVH or TLH.

MyTube

Good visualization of the uterine vessels for a safe dissection.

Stable pneumoperitoneum during application.

Ease of use, increases patient safety and allows a reducedoperating time.

Atraumatic instrument attachment ― In gynaecologic-anatomy adapted design Optimal sizes ―

Reusable attachments in threesizes: 30, 40 and 50mm

Simple reprocessing ―robust, biocompatible high per-formance plastic can be easily processed at 134 ° C / 3 bar

Stable access ―One-way valve as a access for 10 mm instruments

Lightweight ―solid, reusable guiding tube

02-00091 MyTube-colpotomy-set incl. set of valves:

Guiding tube Ø 12 mm (ID) x 184 mm, reusable

Attachment Ø 40 mm x 85 mm, reusable

Attachment Ø 50 mm x 85 mm, reusable

Valve-set Ø 10 mm, sterile for 1 single use,1 piece / pack

Set valve cover Ø 10 mm, sterile for 5 single uses,5 pcs. / pack

Optional: Attachment Ø 30 mm x 70 mm, reusable02-00095

Ordering information

02-00087

02-00088

02-0008902-00094

02-00090

Yours axtrocare-Team