ComPacGEN II
HEAT/COOL/DEFROST68000-VUZ-A
an ISO 9001:2008 Registered Company
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 1 OF 14
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 2 OF 14
EVAPORATOR w/ BLOWER SUB CASE
INSTALLATION KIT
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 3 OF 14
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 4 OF 14
IMPORTANT NOTICE-PLEASE READ
COMPAC GEN IIHEAT/COOL/DEFROST
FOR MAXIMUM SYSTEM PERFORMANCE VINTAGE AIR RECOMMENDS THE FOLLOWING:
VINTAGE AIR SYSTEMS ARE DESIGNED TO OPERATE WITH R134aREFRIGERANT ONLY! USE OF ANY OTHER REFRIGERANTS IS A FIRE HAZARD
AND COULD DAMAGE EITHER YOUR AIR CONDITIONING SYSTEM OR YOUR VEHICLE.
USE OF ANY OTHER REFRIGERANTS WILL VOID ALL WARRANTIES OFTHE AIR CONDITIONING SYSTEM AND COMPONENTS. USE OF THE PROPER
TYPE AND AMOUNT OF REFRIGERANT IS CRITICAL TO PROPER SYSTEMOPERATION. VINTAGE AIR RECOMMENDS OUR SYSTEMS BE CHARGED BY
WEIGHT WITH A QUALITY CHARGING STATION OR SCALE.
THIS KIT DOES NOT CONTAIN HEATER HOSE. YOU MUST PURCHASE 8 FEET OF 5/8" DIA.HEATER HOSE FROM VINTAGE AIR (31800-VUD) OR FROM YOUR LOCAL PARTS RETAILER.
SAFETY SWITCHES:
SERVICE INFO:
R134a SYSTEM
LUBRICANT CAPACITIES: NEW COMPRESSOR - NO ADDITIONAL OIL NEEDED USED COMPRESSOR - CONSULT VINTAGE AIR
REFRIGERANT CAPACITIES FOR VINTAGE AIR SYSTEMS (FOR OTHER SYSTEMS, CONSULT MANUFACTURER GUIDELINES)
A COMPRESSOR SAFETY SWITCH MUST BE INSTALLED ON EVERY A/C SYSTEM. A BINARY SWITCH(PART# 24679-VUS) DISENGAGES THE COMPRESSOR CLUTCH IN CASE OF EXTREME LOW PRESSURECONDITIONS (REFRIGERANT LOSS) OR EXCESSIVELY HIGH HEAD PRESSURE (406 PSI.) TO PREVENTCOMPRESSOR DAMAGE OR HOSE RUPTURE. A TRINARY SWITCH (PART# 24678-VUS) COMBINESHI/LOW PRESSURE PROTECTION WITH AN ELECTRIC FAN OPERATION SIGNAL AT 254 PSI. COMPRESSORSAFETY SWITCHES ARE EXTREMELY IMPORTANT SINCE AN A/C SYSTEM RELIES ON REFRIGERANT TO CARRYLUBRICATION THROUGH THE SYSTEM.
ATTENTION: SYSTEM COMPONENTS: THE COMPRESSOR, EVAPORATOR, CONDENSER & DRIER ARECAPPED. CAPS MAY BE UNDER PRESSURE WITH DRY NITROGEN. BE CAREFUL REMOVING CAPS. DONOT REMOVE CAPS PRIOR TO INSTALLATION. REMOVING CAPS PRIOR TO INSTALLATION WILL CAUSECOMPONENTS TO COLLECT MOISTURE AND LEAD TO PREMATURE FAILURE AND REDUCED PERFORMANCE.
EVACUATE THE SYSTEM FOR 35-45 MINUTES WITH SYSTEM COMPONENTS (DRIER, COMPRESSOR,EVAPORATOR, AND CONDENSER) AT A TEMPERATURE OF AT LEAST 85° F. ON A COOL DAY. THECOMPONENTS CAN BE HEATED WITH A HEAT GUN OR BY RUNNING THE ENGINE WITH THE HEATERON BEFORE EVACUATING. LEAK CHECK AND CHARGE TO SPECIFICATIONS.
CHARGE WITH 1.8 lbs.(1 lbs. 12 oz) OF REFRIGERANT
1/4”Dash
5”
FIGURE 1
FIGURE 1a
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 5 OF 14
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 6 OF 14
LOCATE THE #10 A/C HOSE WITH THE STRAIGHT FITTING. LUBRICATE A #10 O-RING AND THE THREADS ON THE FITTING, AND INSTALL ON THE #10 LINE OF THE EVAPORATOR. TIGHTEN CAREFULLY. REFER TO FIGURES 3 & 3A, PAGE 9.
AFTER CRIMPING HOSES, LOCATE THE #6 A/C HOSE WITH THE STRAIGHT FITTING. LUBRICATE A#6 A/C O-RING AND THE THREADS ON THE FITTING AND INSTALL ON THE EXPANSION VALVE.TIGHTEN CAREFULLY. REFER TO FIGURES 3 & 3A, PAGE 9.
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 7 OF 14
TYP
ICA
L H
OSE
RO
UTI
NG
DIA
GR
AM
DIR
ECTI
ON
OF
REF
RIG
ERA
NT
FLO
W IN
DIC
ATE
D B
Y A
RRO
WS
REC
EIV
ER/D
RIER
(NO
TE F
LOW
DIR
ECTI
ON
)
#6 L
IQU
ID L
INE
SAFE
TY S
WIT
CH
BIN
ARY
(EN
GIN
E D
RIV
EN F
AN
)TR
INA
RY (
ELEC
TRIC
FA
N)
CO
MPR
ESSO
R
CO
ND
ENSE
R
# 8
DIS
CH
ARG
EH
OSE
EVA
PORA
TOR
# 1
0 S
UC
TIO
N H
OSE
906800-V
UZ-
A R
EV E
2/2
8/1
4,
GEN
II C
OM
PAC
HC
D P
G 8
OF
14
LUBRICATE O-RINGS
#6 O-RINGS #8 O-RINGS #10 O-RINGS
O-RINGS
O-RINGSLIDE OVERMALE OVER
MALE INSERT TOSWAGED LIP
SUPPLIED OILFOR O-RINGS
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 9 OF 14
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 10 OF 14
EVAPORATOR UNIT
HEATERCONTROL
VALVE
CLAMPS
GROMMETS
CLAMPS
FROM INTAKEMANIFOLD
HOSECLAMPS
HEATERHOSE
FROM EVAPORATOR
TO WATER PUMP
FROM HEATER CONTROL VALVETO EVAPORATOR
49110-SHQ 4-LEVER CONTROL PANEL OPERATION
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 11 OF 14
V V
V
V
V
V
REQUIRED
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 12 OF 14
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 13 OF 14
.
EVAPORATOR w/ BLOWER SUB CASE
INSTALLATION KIT
906800-VUZ-A REV E 2/28/14, GEN II COMPAC HCD PG 14 OF 14