Research ArticleAn Advanced Multicarrier Residential Energy Hub SystemBased on Mixed Integer Linear Programming
Yue Yuan,1 Angel A. Bayod-Rújula ,2 Huanxin Chen,3 Amaya Martínez-Gracia,4
Jiangyu Wang,3 and Anna Pinnarelli5
1China-Eu Institute for Clean and Renewable Energy, Huazhong University of Science and Technology, Wuhan 430074, China2Department of Electrical Engineering, University of Zaragoza, Spain3Department of Refrigeration & Cryogenics, Huazhong University of Science and Technology, 1037 Luoyu Road,430074 Wuhan, China4Department of Mechanical Engineering, University of Zaragoza, Spain5Department of Mechanical, Energy and Management Engineering, University of Calabria,Arcavacata of Rende-Cosenza 87036, Italy
Correspondence should be addressed to Angel A. Bayod-Rújula; [email protected]
Received 27 February 2019; Accepted 14 May 2019; Published 9 June 2019
Academic Editor: Francesco Riganti-Fulginei
Copyright © 2019 Yue Yuan et al. This is an open access article distributed under the Creative Commons Attribution License,which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
This work proposes a multicarrier energy hub system with the objective of minimizing the economy cost and the CO2 emissions of aresidential building without sacrificing the household comfort and increasing the exploitation of renewable energy in daily life. Theenergy hub combines the electrical grid and natural gas network, a gas boiler, a heat pump, a photovoltaic plant, and aphotovoltaic/thermal (PV/T) system. In addition, to increase the overall performance of the system, a battery-based energystorage system is integrated. To evaluate the optimal capacity of each energy hub component, an optimization schedulingprocess and the optimization problem have been solved with the YALMIP platform in the MATLAB environment. The resultshowed that this advanced system not only can decrease the economic cost and CO2 emissions but also reduce the impact toelectrical grid.
1. Introduction
As the climate becomes increasingly polarized today, thedemand for electricity and heating load of buildings alsoincreases daily, sometimes even accounting for half of thetotal building energy consumption. Relying only on the elec-trical grid and natural gas network input to meet customerdemand, energy utilization efficiency will be extremely low.Not only can the grid meet a huge pressure during peak loadperiod, but it will also produce large amounts of CO2 whichwill aggravate urban heat island effect, which makes thedemand of polarization phenomenon more serious. In recentyears, although renewable energy generation has been greatlydeveloped, the constraint in terms of transport capacity of the
electrical grid still becomes a bottleneck of its participation inenergy supply. In last years, in order to provide a solution tothese limits, a large number of small renewable energy gener-ators have been connected to the distribution networks [1].
An energy hub is a multicarrier energy system consistingof multiple energy conversion, storage, and/or network tech-nologies and is characterized by some degree of local control.Conception of an energy hub (EH) system has been firstproposed on the research project “Vision of Future EnergyNetwork” by ETH, Zurich, in 2007 [2]. In this future visionof energy networks, an energy hub system is a highly abstractunit structure, providing a great opportunity for systemschedulers and operation workers to create a more efficientsystem [3]. An energy hub is an initial part of a multienergy
HindawiInternational Journal of PhotoenergyVolume 2019, Article ID 1384985, 12 pageshttps://doi.org/10.1155/2019/1384985
system, which can accommodate various forms of energyinput and diversified load types [4]. Because of this diversi-fied form of energy carrier, the energy hub system can realizecollaborative optimization for various forms of energy [5]. Inorder to ensure that the energy hub is operated under asecure and economic and environmentally friendly condi-tion, the research for energy hub systems mainly focuses onthe component type or the capacity of an energy hub andthe energy hub optimal dispatch [6–9]. Different from usingtraditional flat traffic, Le Blond et al. [10] introduced“dynamic traffic” to drive energy storage system operationto control energy hub system operation under minimum costand CO2 emissions. Beigvand et al. [11] proposed a new algo-rithm named SAL-TVAC-GSA to dispatch energy hub eco-nomic cost. In [9], Setlhaolo et al. present a residentialenergy hub model for a smart home as a modified frameworkof conventional energy hubs in a smart grid with consider-ation of heat pump water heater, coordination of sources,and carbon emission. Lingang Industrial Park is an engineer-ing example [12], whose results provide a technical supportfor the construction of a resource-saving and environment-friendly harbour. In [13], a residential building and its elec-trical equipment are modelled as an energy hub system,including washing machine, dryer, HVAC system, refrigera-tor, and lighting equipment, to minimize energy cost, carbonemission, and peak load for optimal scheduling under thepremise of maintaining the comfort of the users. In addition,a cloud computing framework is present to achieve the effec-tive management of data and information. Ma et al. [8] pre-sented a community micro energy grid in four differentscenarios on a typical summer day, and the roles of renewableenergy, energy storage devices, and demand response are dis-cussed separately.
Due to the fact that an energy hub is an efficient meansfor the optimal exploitation of renewable energy generation,research focuses are generally concentrated on variablekinds of energy inputs [14–16]. Sharif et al. [17] presenteda simulation model for an energy hub which major energysource is renewable energy (wind and solar energy) and nat-ural gas. Ha et al. [18] proposed an energy hub system forresidential buildings with solar energy and battery-basedenergy storage systems, and the results showed that thisenergy system structure conforms to the characteristics ofresidential buildings’ energy consumption. Furthermore, itcan reduce costs and save energy consumption at the sametime. However, little research considers the integration ofPV/T systems into an energy hub. PV/T can generate waterheating and electricity at the same time [19], being an idealcomponent for residential energy hub system. This paperproposes a multicarrier energy hub (EH) system based onsolar PV and PVT systems and a battery-based energy stor-age system. Moreover, an optimal scheduling strategy isproposed to calculate the optimum capacity of each compo-nent in order to minimize the energy cost and the CO2emission. The optimization problem has been solved withthe YALMIP platform in the MATLAB environment. Theproposed EH system is tested for a residential applicationaccording to the characteristics of buildings of apartmentsin Zaragoza, Spain.
2. Description of the Building SimulationModeland Optimization Process
A residential building located in Zaragoza, in the centre ofSpain, with a simple but typical architecture as shown inFigure 1 has been simulated in EnergyPlus software. Cli-matic parameters, including ambient temperature, solar irra-diation, and wind speed, have been taken from the Zaragozalocal dataset. The simulation building is a 3-storey resi-dential building, 1660.73m2, with five 3-bedroom apart-ments per floor. It has been considered that 4 people live ineach apartment.
Solar irradiation in Zaragoza is abundant (see Figure 2),so it is reasonable to introduce photovoltaic (PV) systemsor PV/T systems into energy hubs to decrease the energycosts and the CO2 emissions.
The electricity price has been calculated from hourly localreal-time price in Spain in 2017, as it is shown in Figure 3.The considered gas prices were 0.0667 euro/kWh and0.0865 euro/kWh according to Spain gas prices for house-hold consumers, all taxes and levies included in the firstand second semester of 2017, respectively [20].
The daily energy consumption of the simulation buildingfor four seasons is shown in Figure 4; blue bars represent elec-tricity (including air conditioning) consumption and redcurve represents heating demand (including heating and hotwater demand). The highest electricity demand can approach220 kWh per day (sum of the blue bar in Figure 4 for summer)and the highest heating demand is approximately 55 kWhper day (sum of grey values in Figure 4, winter).
Relying only on the electrical grid and natural gasnetwork to satisfy electricity and heating demands of thisbuilding, the economic cost is 11713 euro/year and the CO2emission is 21711 kg/year (see Table 1).
An EH system has been so developed with the aim tominimize the energy cost and the CO2 emissions but alsofor relief grid’s pressure. Firstly, in accordance with the build-ing’s energy consumption pattern, an EH system with only agas boiler (GB), a heat pump (HP), a PV plant (PV), and aPV/T system has been designed. A capital cost of 800euro/kW has been considered for the GB and 1000 euro/kWfor the HP, both with an estimated lifetime of 20 years. In thecase of the PV plant, a capital cost of 1500 euro/kWp hasbeen considered (including inverter, wire, and protections)and 700 euro/m2 for the PVT systems and their lifetime hasbeen considered to be 30 years. Later, the EH system has beenimproved with the integration of a BESS. The EH systemdesign has been optimized by the optimization schedulingprocess as shown in Figure 5. The optimization problem issolved by using Mixed Integer Linear Programming (MILP)on the YALMIP platform in the MATLAB environment.Since there are too many elements included in the EH sys-tem, it is difficult to get the optimal solution directly througha single-layer optimization process. Therefore, the EH systemdesign is threefold. Firstly, only the HP and the PV (with var-iable efficiency) are considered as elements involved in theoperation of the EH system and for this configuration theiroptimum capacity is obtained. Then, operating the EH sys-tem under this optimum capacity, a PV/T (with variable
2 International Journal of Photoenergy
thermal efficiency) is introduced into the EH system and theoptimization schedule is solved again to calculate the optimalPV/T capacity. Finally, the BESS is integrated and the finaloptimal capacity of each element of the EH system isobtained. The entire process is modelled taking into accountthe dynamic price of electricity and natural gas.
The optimal operation model is formulated with the mul-tiple objective of minimizing the entire cost, CO2 emission,and peak load:
min 〠T−8760
t−1Pele t pele t Δt + Pgas t × pgas t Δt + Finstall + f O&M,
min 〠T−8760
t−1Pele t Eele t Δt + 〠
T
t−1Pgas t Egas t Δt,
min Pmaxele t ,
1
where Pele t and Pgas t represent the price of electricity andgas from the main grid, respectively. Eele t and Egas trepresent the CO2 emission index of electricity and gas,respectively. Finstall represents the installation fee of allcomponents, and FO&M represents the operation and man-agement fee of all components.
Electricity balance constraints and heat balance con-straints can be formulated as equations (2) and (4),respectively.
Lele t = eele,grid t + eele,PV t + eele,PV/T t
− eele,hp t − Sele,B t ,2
eele,grid t = Pele,grid t ηele,grid t ,
eele,PV t = APVG t ηele,PV t ,
eele,PV/T t = APV/TG t ηele,PV/T t ,
3
where eele,grid t is the electricity supplied from the main grid,eele,PV t is the electricity supplied from the PV panel, andeele,PV/T t is the electricity supplied from the PV/T panel;APV and APV/T are the surface areas of the PV panel andthe PV/T panels. G t is the solar irradiance. eele,hp t repre-sents the electrical input of the heat pump at time, which isdetermined by heating balance constraints. And Sele,B t isthe energy input or output from the battery.
Lheat t = hheat,grid t + hheat,PV/T t + hele,hp t , 4
hheat,grid t = Pheat,grid t ηheat,grid t ,
hheat,hp t = COPhp t eele,hp t ,5
where hheat,grid t and hheat,hp t represent the heating sup-plied from natural gas net and heat pump, respectively, andhheat,PV/T t is the heat supplied from the PV/T panel.
Solving the layer-by-layer optimization is helpful to knowthe impact of each element on the EH system and simplifythe solving process at the same time. The building perfor-mance throughout the year is valuated with all the compo-nents at its optimum capacity.
3. The EH Structure and Matrix Representation
The first structure of the EH system proposed for the build-ing is shown in Figure 6. Initially, a gas boiler (GB), a heatpump (HP), a PV plant (PV), and a PV/T system are consid-ered besides the electrical grid and the natural gas network.
Figure 1: Building structure simulated in EnergyPlus software.
0
Time (hour)0 2 4 6 8 10 12 14 16 18 20 22 24
200
400
Irra
diat
ion
(W/m
2 )
600
800
1000
JanFebMarApr
MayJunJulAug
SepOctNovDec
Figure 2: Average daily solar irradiation in Zaragoza for eachmonth.
60
0 2 4 6Month
8 10 12
80
100
120
Cos
t (eu
ro/M
Wh)
140
160
180
200
Figure 3: Actual hourly real-time electricity price in 2007.
3International Journal of Photoenergy
The basic mathematical model of the EH system is [21]
L = f P , 6
where L expresses the energy (electricity and heating)demand and considers the power supply.
The basic matrix function of the EH system can bewritten as
L1
L2
⋮
Ln n×1
=
c11 c12 ⋯ c1m
c21 c22 ⋯ c2m
⋯
cn1 cn2 ⋯ cnm n×m
P1
P2
⋮
Pm m×1
7
In this function, cijth is the coupling factor, which rep-
resents the conversion efficiency between the ith energyinput and the jth energy output.
In this framework, the relationship between the demandside and the supply side of the EH system is formulated witha coupling matrix indicated as follows:
L = C1 C2P
R, 8
L = C1P + C2R 9
Energy demand matrix L is equal to coupling matrix Ctimes the installed generating capacity of P and the renewableenergy R.
C1P can be developed as
C1P = ηgrid ηheatpump ηboiler
Pgrid
Pheatpump
Pboiler
, 10
141210
86420
1:00 4:00 7:00
Spring electricity loadSpring heating load
10:00 13:00
Spring
16:00 19:00 22:00
1614121086420
(a)
141210
86420
1:00 4:00 7:00
Summer electricity loadSummer heating load
10:00 13:00
Summer
16:00 19:00 22:00
1614121086420
(b)
141210
86420
1:00 4:00 7:00
Autumn electricity loadAutumn heating load
10:00 13:00
Autumn
16:00 19:00 22:00
1614121086420
(c)
141210
86420
1:00 4:00 7:00
Electricity loadHeating load
10:00 13:00
Winter
16:00 19:00 22:00
1614121086420
(d)
Figure 4: Daily energy consumption of the simulation building for different seasons.
Table 1: Cost, energy consumption, and CO2 emissions for the traditional supply.
Cost(euro/year)
CO2 emission(kg/year)
Gas consumption(kWh/year)
Electricity consumption(kWh/year)
11713 21711 20518 62589
4 International Journal of Photoenergy
Design an initial energy hub system with heatpump and PV system
Select multiple objectives for optimization
Is it theoptimalvalue?
Yes
No
Simulation software
Input data (whole year)
Main grid electricity and natural gas feeComponents install, operation and fixed fee
Meteorological data
Occupant schedule
Electricity demand
HVAC system demand
Heating demand
Final optimization schedule
Each components operation condition
Annual economic cost Annual CO2 emission
Real data input
Typical meteorological year data
Carbon dioxide emission index
Electricity & natural gas price
Components install, operation andmanagement fee
Design multiple-carrier energy hub system
Building energy consumption form analysis
Energy generation and conversion componentselection
Energy hub optimization scheduling withminimize cost, emission and peak load.
Operating energy hub under electricity and heatinginput and output conservation
Introduce PV/T system into the original system
PV/T systemmodel establish
PV/T systemcapacity validation
Variable proportion ofPV/T system to entire PV
system
Select multiple objectives for optimization
Is it theoptimalvalue?
No
Yes
Introduce energy storage system into the originalsystem
Battery systemmodel establishHot water tankmodel establish
Select multiple objectives for optimization
Is it theoptimalvalue?
Yes
No
Each component design with capacity limitation andcost calculation
Components contact with input-output balancelimitation
Heat pumpmodel establish
PVmodel establish
Heat pumpcapacity
validationPV capacityvalidation
Battery systemcapacity validation
Hot water tankcapacity validation
Figure 5: EH system optimization scheduling process.
5International Journal of Photoenergy
C1P = ηgridPgrid + ηheatpumpPheatpump + ηboilerPboiler , 11
ηgridPgrid =ηgrid,ele
ηgrid,heat
Pgrid,ele
Pgrid,heat,
ηheatpumpPheatpump =ηheatpump,ele
ηheatpump,heat
Pheatpump,ele
Pheatpump,heat,
ηboilerPboiler =ηboiler,ele
ηboiler,heat
Pboiler,ele
Pboiler,heat
12
In (7), due to the value of ηboiler,elePboiler,ele which is equalto 0, the equation can be represented as
C1P =ηgrid,elePgrid,ele + ηheatpump,elePheatpump,ele
ηgrid,heatPgrid,heat + ηheatpump,heatPheatpump,heat + ηboiler,heatPboiler,heat
13
C2R can be represented as
C2R =ηPV
ηPV/T
PPV
PPV/T
, 14
C2R =ηPV,elePPV,ele + ηPV/T,elePPV/T,ele
ηPV,heatPPV,heat + ηPV/T,heatPPV/T,heat15
Because the value of ηPV,heatPPV,heat is equal to 0, C2R canbe represented as
C2R =ηPV,elePPV,ele + ηPV/T,elePPV/T,ele
ηPV/T,heatPPV/T,heat16
For each EH system component, the following parame-ters are included: capacity, efficiency, capital cost, fixed cost,variable cost, and lifetime as reported in Table 2. The electric-
ity net emission factor considered is 0.28 kg/kWh and0.204 kg/kWh for natural gas [22].
In real-life application, the PV efficiency is not a constantvalue; it varies with such parameters as solar irradiation,environmental temperature, and PV panel surface tempera-ture. The working temperature of the cells (Tc) dependsexclusively on the solar irradiation G and the ambient tem-perature (Ta) according to the linear function
Tc − Ta = C2G, 17
where C2 is represented by
C2 =NOCT °C − 20
800W/m2 18
NOCT in equation (18) is the nominal operating celltemperature defined as the temperature reached by opencircuited cells in a module under 800W/m2 cell surface irra-diance and ambient temperature of 20°C and so on. NOCT ofa typical commercial module is approximately 45 ± 2°C,accordingly, C2 is approximately equal to 0.3°C/(W/m2).
Therefore, if the PV nominal power value under STCcondition Pn is known, it will be possible to figure outthe PV power value at any time via
Pm = PnGGSTC
1 − γ Tc − 25 , 19
where GSTC is the irradiation under standard test conditions(STC), which is equal to 1000W/m2.
In a conventional PV plant of crystalline silicon, the con-version efficiency is in the range 15%-20% so 75% to 80% ofthe solar energy is not being used effectively [22]. Besides, theunused solar energy will heat up the panel, causing a decreasein the efficiency of the electricity generation.
Transferring the thermal energy to a heat transfer fluid,we obtain useful thermal energy and refrigerate the photo-voltaic cells at the same time. This system, which can makeuse of solar light and thermal simultaneously, is calledphotovoltaic/thermal integrated system (PV/T system)(Figure 7).
Electricity grid
Heatpump
Photovoltaic/thermal
planeElectricitydemand
Heatingdemand
Photovoltaic
Nature gas grid
Gas boiler
Figure 6: EH system structure for the building.
6 International Journal of Photoenergy
The calculation about the thermal part of the PV/Tsystem is shown as follows:
QS =G × AC , 20
QC = ηh ×QS, 21
QC = cpw ×mwC × twe c − tws c , 22
Qd = AC ×Ud × twe c − t0 , 23
Qcons = cpw ×mr × td ini − tpipe , 24
inct
0QC −Qd −Qcons = cpw ×mwd × td fin − td ini
= cpw ×mr × tconsig − td fin
25
QS represents the radiation projected onto the PV plane, QCis the heat absorbed by the panel, ηh is the heating efficiencyof the PV/T systems, mwC is the fluid mass under the panel,twe c and tws c are output and input temperature of underpanel fluid, respectively, Qd is the heat loss of natural con-vection heat transfer between the tube and the environment,and t0 represents the ambient temperature. Qcons refers tothe heat loss of direct heat transfer between the fluid inthe pipe and the pipe wall. td ini and td fin are fluid inputand output pipe temperature, respectively. tpipe is the tem-perature of pipe shall and tconsig is the final demand fluidtemperature. Qa is the auxiliary energy supply. The thermo-dynamic relationship characterizing the PV/T is shown inFigure 8.
In addition, the thermal part of the PV/T systemefficiency ηh is influenced by many factors, such as
solar irradiation and pipe fluid temperature, as repre-sented in
ηh = η0 − a1 ×Te − Ta
G− a2 ×
Te − Ta
G26
In this equation, η0 means the optical performance of thePV/T system, a1 and a2 are the thermal loss coefficients, in thispaper set as 3.3 (W/m2)/K and 0.018 (W/m2)/K2, respectively,and I represents solar irradiation. Te is the average value ofpipe fluid temperature and Ta is the ambient temperature.
First of all, the scale of the PV/T system water tank isshown in Table 3.
Vd = πDd
2
2Hd , 27
Ad = 2πDd
2
2+ πDdHd 28
The temperature of the PV and PV/T panels is shown inFigure 9. Obviously, the PV/T surface temperature is higher
Table 2: EH system component parameters.
Component name Efficiency (%) Capital cost (€/kW or €/m2) Fixed cost (€/kW) Variable cost (€/kWh) Lifetime (years)
Gas boiler 70 800 10 0.02 20
Heat pump 3.2 (COP) 1000 8.7 0 20
PV Variable 250 2 0 30
PV/T Variable 700 10 0 30
Photoelectrictransformation
Electricityoutput
Opto-thermaltransformationSolar
irradiation
HeattransferPV/T
plan
e
Auxiliary heating
Heatingoutput
Figure 7: The schematic of the PV/T system.
Energydirection
Qs Qc
Qa
Qu
Qcons
Qd
Figure 8: Thermodynamic relationship in the PV/T systems.
7International Journal of Photoenergy
than the PV panel in summer season. In order to decrease thePV/T surface temperature, the hot water tank size should beenlarged. In this case, the hot water tank size is related topanel area, when Vd/Ac value is increased from 0.1 to 0.2,the hot water tank will become bigger gradually. Figure 9 pre-sents the panel temperatures for Vd/Ac = 0 2.
The thermal efficiency of the PV/T system is shown inFigure 10.
The average daily electricity generation for 1m2 PV andPV/T panel with an 18% efficiency is shown in Figure 11for every month. A PV/T system can generate more electric-ity in winter months and part of spring and autumn.
4. Energy Hub Results
The optimum values of the EH system components’ capacityfor the building under analysis were calculated in a previouspaper [22] for a 20 kW HP and 65m2 of PV systems. Withthe combination of PV+PVT, the best results were obtainedfor a HP of 20 kW, 36m2 of PV modules, and 30m2 ofPV/T. With the operating condition of 20 kW HP and65m2 of PV systems, the cost reaches the minimum value10727 euro/year. The CO2 emission achieved 13560 kg/yearat the meantime. Comparing these values with the total sup-ply of electricity and heat from the electrical grid and naturalgas network, respectively (see Table 1), a reduction of 8.42%in cost was obtained with a reduction of 37.54% in CO2 emis-
sion. Otherwise, the results considering the optimal capacityof PV/T and PV systems (36m2 of PV and 30m2 of PV/T)are shown in Table 4. Compared with the result shown inTable 1, a great improvement is reached. A decrease of10.61% in cost with a reduction of 30.02% in electricity con-sumption and 60.07% in gas consumption is achieved. Areduction of 39.66% in CO2 emissions is also obtained.
5. Energy Hub with a Battery-Based ESS
The renewable generation is sometimes greater than cus-tomer’s demand and part of electricity generated from a
Table 3: Hot water tank dimension.
Name Signal Value Unit
Tank volume Vd 0.326 m3
Panel surface area Ac 3.26 m2
Tank height Hd 0.744 m
Tank bottom diameter Dd 0.744 m
Tank surface area Ad 5.22 m2
35
30
25
20
Tem
pera
ture
15
10
5
0
3530
4540
5550
60
PV in Jan
252015
Time (hour)0 10 20 30
PV/T in JanPV/T in JunPV in Jun
Figure 9: Panel temperature comparison between the PV and PV/Tsystems.
0.0
0.2
0.4
2 4 6 8 10 12 14 16 18 20 22 24Time (hour)
Effic
iency
JanFebMarApr
MayJunJulAug
SepOctNovDec
Figure 10: Daily efficiency for different months.
0.0Apr Aug
MonthDec
0.3
0.6G
ener
atio
n (k
Wh)
0.9
1.2
PVPV/T
Figure 11: Average daily electricity generation for 1m2 of PV andPV/T panel for every month.
Table 4: Cost, electricity and gas consumption, and CO2 emissionsfor the optimal sizing (20 kW of HP, 36m2 of PV, and 30m2 ofPV/T).
Cost(euro/year)
Electricityconsumption(kWh/year)
Gasconsumption(kWh/year)
CO2emission(kg/year)
10470 43800 4419 13100
8 International Journal of Photoenergy
PV plant must be injected into the electrical grid orwasted. In order to improve the EH system performance,a BESS is integrated. The BESS provides a solution incase the renewable energy cannot be injected due to theregulation code (zero-injection schemes) or due to techni-cal restrictions at that time. It is even able to providevoltage and frequency support and contribute to demandresponse procedures such as peak shaving. So, theadvanced EH system structure is shown in Figure 12 withthe BESS integrated.
In this work, the battery is optimally charged and dis-charged to compensate the generation fluctuation of the PVand PV/T. The BESS dynamic model used is
E × SOCt = E × SOC0 + ts 〠t
γ=1ηcPb,γ −
Pb,γ
ηd, 1 ≤ t ≤N
29
E is the BESS capacity, SOC0 is the initial SOC of theBESS, SOCt is the SOC at the given time t, Pb,γ and Pb,γ
are the continuous variables at time step γ, and ts∑tγ=1ηcPb,γ
Pe
Pg
Heat pump
Gas boiler
Photovoltaic
PV/T
Le
Lh
Battery
Energyhub
Gas routeElectricity routeHeating route
Figure 12: Ultimate energy hub structure for a building.
Table 5: Advanced EH system performance for several BESSsizes.
Batterycapacity(kWh)
Cost(euro/year)
Electricityconsumption(kWh/year)
CO2 emission(kWh/year)
1 10211 41690 12520
2 10205 41650 12510
3 10200 41620 12500
4 10195 41590 12500
5 10190 41560 12490
6 10185 41530 12480
7 10179 41500 12470
10 10165 41410 12450
12 10214 41340 12430
15 10230 41280 12410
0.14
0.16
Elec
tric
ity p
rice (
euro
/kW
h) 0.18
Spring
3 6 9 12 15Time (hour)
18 21 24
SummerAutumnWinter
Figure 13: Daily electricity price for different seasons.
9International Journal of Photoenergy
and ts∑tγ=1 Pb,γ/ηd are the BESS energy during the charging
and discharging period, respectively.BESS constraints are applied to the model:
0 2 ≤ SOCt ≤ 0 8, t = 1,⋯,N , 30
Pb,t × Pb,t = 0, t = 1,⋯,N 31
N is the number of sampling intervals; in this case, itis 8760.
The capacity limits are given in equations (30) and (31),which does not allow the BESS to charge and discharge atthe same time. This constraint also permits the idle stateof BESS.
The BESS involved here is an ideal model, which has alinear charge state and a SOC around 0.2 to 0.8. The optimi-zation objective of BESS is the same as the previous system,minimum cost and minimum CO2 emission. Due to theeconomic goal of the whole system, the BESS will becharged during the low electricity price period, and whenthe electricity price is high, it will discharge energy to satisfythe demand.
Now the matrix of this advanced EH system is shownas follows; S is the storage coupling matrix and E is thestorage energy.
L = C1P + C2R − SE 32
Table 5 shows the results of the simulation for differ-ent sizes of battery. The lowest cost is obtained for a bat-tery of 10 kWh of capacity. Comparing with the results ofTable 4, 2.91% cost and 5.46% CO2 emission will be saved.Comparing with the results of Tables 1, 13% cost, 42.7%CO2 emission, and 33.8% will be saved. Therefore, thesimulation results confirm that adopting the proposedadvanced EH system and the related optimization schedul-ing process not only significantly promotes efficiency andcost savings but also provides relief from the global pres-sure of greenhouse effect.
Four representative days for the four seasons of the yearhave been selected. Daily electricity prices for these days arepresented in Figure 13. In Figure 14, the energy absorbedfrom PV, PV/T, and electrical grid for these representativedays is shown.
14
12
10
8
6
4
2
0
Spring
Time
Supp
lied
from
grid
14
12
10
8
6
4
2
0
Summer
Time
Supp
lied
from
grid
14
12
10
8
6
4
2
0
Autumn
Time
Supp
lied
from
grid
14
12
10
8
6
4
2
0
Winter
3:00 6:00 9:00 12:00 15:00 18:00 21:00 24:00 3:00 6:00 9:00 12:00 15:00 18:00 21:00 24:00
3:00 6:00 9:00 12:00 15:00 18:00 21:00 24:00 3:00 6:00 9:00 12:00 15:00 18:00 21:00 24:00Time
Supp
lied
from
grid
PVT generationPV generation
Supplied from gridLoad
Figure 14: Energy structure in the proposed energy hub for different days of the four seasons.
10 International Journal of Photoenergy
Sometimes the supply is not totally equal to the demanddue to the presence of BESS. When electricity price is high,the EH system avoids the supply of electricity from the elec-trical grid. In Figure 14, it is easy to find out that the EH sys-tem generates more electricity than the demand in autumnand winter which is related to the fact that electricity priceis higher in these two seasons; indeed, the EH system choosesdischarging via BESS to meet the customers’ demand.
During the high demand hours, the EH system showedan outstanding performance for reduction of the absorptionof energy from the electrical grid (Figure 15). Calculatingaccording to that high demand hours from 8:00 a.m. to16:00 p.m., the EH system can reduce 65.3%, 61.6%, 57.9%,and 33.9% absorption from the electrical grid. Meanwhile,during this period, 6.21 euro, 7.95 euro, 6.37 euro, and 4.14euro are saved per day, respectively, for this building. Besides,
due to the function of BESS, the electrical grid will supplymore electricity when the price is relatively low.
6. Conclusions
This paper proposes an advanced multicarrier energy hubintegrating not only generation components such as PVand PV/T systems but also a battery-based energy storagesystem to improve the performance. The optimal capacityof each component of the multicarrier energy hub in orderto minimize the energy cost and the CO2 emissions is basedon the use of an optimization scheduling process solved onthe YALMIP platform in the MATLAB environment. Thesimulation results confirm that large-scale utilization ofthe proposed approach will lead to significant cost andCO2 savings.
150.18
0.16
Euro
0.14
12
9
6
3
04 8 12 16 20 24
Spring
Time (hour)
kWh
Power loadMain grid inputElectricity price
(a) Spring
150.18
0.16
Euro
0.14
12
9
6
3
00 8 16 24
Summer
Time (hour)
kWh
Power loadMain grid inputElectricity price
(b) Summer
150.18
0.16
Euro
0.14
12
9
6
3
00 8 16 24
Autumn
Time (hour)
kWh
Power loadMain grid inputElectricity price
(c) Autumn
150.18
0.16
Euro
0.14
0.13
12
9
6
3
08 16 24
Winter
Time (hour)
kWh
0
Power loadMain grid inputElectricity price
0.17
0.15
(d) Winter
Figure 15: Comparison between electrical grid supply without the EH system and with the advanced EH system for different representativedays for the four seasons.
11International Journal of Photoenergy
Data Availability
The data used to support the findings of this study areincluded within the article.
Conflicts of Interest
The authors declare that there is no conflict of interestregarding the publication of this paper.
Acknowledgments
The authors gratefully acknowledge the support of NationalNatural Science Foundation of China (Grant 51876070)and (Grant 51576074).
References
[1] A. A. Bayod-Rújula, “Future development of the electricitysystems with distributed generation,” Energy, vol. 34, no. 3,pp. 377–383, 2009.
[2] H. X. Zhao and F. Magoulès, “A review on the prediction ofbuilding energy consumption,” Renewable and SustainableEnergy Reviews, vol. 16, no. 6, pp. 3586–3592, 2012.
[3] P. Favre-Perrod, “A vision of future energy networks,” inPower engineering society inaugural conference and expositionin Africa, pp. 13–17, Durban, South Africa, 2006.
[4] G. T. Ayele, P. Haurant, B. Laumert, and B. Lacarrière, “Anextended energy hub approach for load flow analysis of highlycoupled district energy networks: illustration with electricityand heating,” Applied Energy, vol. 212, pp. 850–867, 2018.
[5] P. Cui, J. Shi, F. Wen et al., “Optimal energy hub configurationconsidering integrated demand response,” Dianli ZidonghuaShebei/Electric Power Automation Equipment, vol. 37,pp. 101–109, 2017.
[6] M. Moeini-Aghtaie, A. Abbaspour, M. Fotuhi-Firuzabad,and E. Hajipour, “A decomposed solution to multiple-energy carriers optimal power flow,” IEEE Transactions onPower Systems, vol. 29, no. 2, pp. 707–716, 2014.
[7] A. Sheikhi, M. Rayati, S. Bahrami, and A. MohammadRanjbar, “Integrated demand side management game in smartenergy hubs,” IEEE Transactions on Smart Grid, vol. 6, no. 2,pp. 675–683, 2015.
[8] T. Ma, J. Wu, and L. Hao, “Energy flow modeling and optimaloperation analysis of the micro energy grid based on energyhub,” Energy Conversion and Management, vol. 133,pp. 292–306, 2017.
[9] D. Setlhaolo, S. Sichilalu, and J. Zhang, “Residential load man-agement in an energy hub with heat pump water heater,”Applied Energy, vol. 208, pp. 551–560, 2017.
[10] S. Le Blond, R. Li, F. Li, and Z. Wang, “Cost and emission sav-ings from the deployment of variable electricity tariffs andadvanced domestic energy hub storage management,” in2014 IEEE Pes General Meeting | Conference & Exposition,pp. 1–5, National Harbor, MD, USA, July 2014.
[11] S. D. Beigvand, H. Abdi, and M. La Scala, “A general model forenergy hub economic dispatch,” Applied Energy, vol. 190,pp. 1090–1111, 2017.
[12] X. Tian and R. Zhao, “Energy network flowmodel and optimi-zation based on energy hub for big harbor industrial park,”Journal of Coastal Research, vol. 73, pp. 298–303, 2015.
[13] M. C. Bozchalui, S. A. Hashmi, H. Hassen, C. A. Canizares,and K. Bhattacharya, “Optimal operation of residential energyhubs in smart grids,” IEEE Transactions on Smart Grid, vol. 3,no. 4, pp. 1755–1766, 2012.
[14] M. Rastegar andM. Fotuhi-Firuzabad, “Load management in aresidential energy hub with renewable distributed energyresources,” Energy and Buildings, vol. 107, pp. 234–242, 2015.
[15] K. Orehounig, R. Evins, V. Dorer, and J. Carmeliet, “Assess-ment of renewable energy integration for a village using theenergy hub concept,” Energy Procedia, vol. 57, pp. 940–949,2014.
[16] M. Sepponen and I. Heimonen, “Business concepts for dis-tricts’ energy hub systems with maximised share of renewableenergy,” Energy and Buildings, vol. 124, pp. 273–280, 2016.
[17] A. Sharif, A. Almansoori, M. Fowler, A. Elkamel, andK. Alrafea, “Design of an energy hub based on natural gasand renewable energy sources,” International Journal ofEnergy Research, vol. 38, no. 3, pp. 363–373, 2014.
[18] T. Ha, Y. Zhang, V. V. Thang, and J. Huang, “Energy hubmodeling to minimize residential energy costs consideringsolar energy and BESS,” Journal of Modern Power Systemsand Clean Energy, vol. 5, no. 3, pp. 389–399, 2017.
[19] P. G. Charalambous, G. G. Maidment, S. A. Kalogirou, andK. Yiakoumetti, “Photovoltaic thermal (PV/T) collectors: areview,” Applied Thermal Engineering, vol. 27, no. 2-3,pp. 275–286, 2007.
[20] Eurostat, https://ec.europa.eu/eurostat/statistics-explained/index.php/Natural_gas_price_statistics#Natural_gas_prices_for_household_consumers.
[21] A. Parisio, C. del Vecchio, and A. Vaccaro, “A robust optimi-zation approach to energy hub management,” InternationalJournal of Electrical Power & Energy Systems, vol. 42, no. 1,pp. 98–104, 2012.
[22] A. A. Bayod-Rújula, Y. Yuan, A. Martínez-Gracia, J. Wang,J. Uche, and H. Chen, “Modelling and simulation of a buildingenergy hub,” Proceedings, vol. 2, no. 23, article 1431, 2018.
12 International Journal of Photoenergy
TribologyAdvances in
Hindawiwww.hindawi.com Volume 2018
Hindawiwww.hindawi.com Volume 2018
International Journal ofInternational Journal ofPhotoenergy
Hindawiwww.hindawi.com Volume 2018
Journal of
Chemistry
Hindawiwww.hindawi.com Volume 2018
Advances inPhysical Chemistry
Hindawiwww.hindawi.com
Analytical Methods in Chemistry
Journal of
Volume 2018
Bioinorganic Chemistry and ApplicationsHindawiwww.hindawi.com Volume 2018
SpectroscopyInternational Journal of
Hindawiwww.hindawi.com Volume 2018
Hindawi Publishing Corporation http://www.hindawi.com Volume 2013Hindawiwww.hindawi.com
The Scientific World Journal
Volume 2018
Medicinal ChemistryInternational Journal of
Hindawiwww.hindawi.com Volume 2018
NanotechnologyHindawiwww.hindawi.com Volume 2018
Journal of
Applied ChemistryJournal of
Hindawiwww.hindawi.com Volume 2018
Hindawiwww.hindawi.com Volume 2018
Biochemistry Research International
Hindawiwww.hindawi.com Volume 2018
Enzyme Research
Hindawiwww.hindawi.com Volume 2018
Journal of
SpectroscopyAnalytical ChemistryInternational Journal of
Hindawiwww.hindawi.com Volume 2018
MaterialsJournal of
Hindawiwww.hindawi.com Volume 2018
Hindawiwww.hindawi.com Volume 2018
BioMed Research International Electrochemistry
International Journal of
Hindawiwww.hindawi.com Volume 2018
Na
nom
ate
ria
ls
Hindawiwww.hindawi.com Volume 2018
Journal ofNanomaterials
Submit your manuscripts atwww.hindawi.com