TECHNICAL SPECIFICATION TRADITIONAL Products GRP TRADITIONAL Due to our policy of maintaining a continuous review of product performance and materials of construction we reserve the right to amend the design and dimensions of the products illustrated in this publication at any time and without prior notice. Quinshield ltd Capel Hendre Ammanford, Carmarthenshire SA18 3SJ Tel: 01269 832220 Fax: 01269 832221 email: [email protected] www.quinshield.com Quinshield Quinshield ltd Capel Hendre Ammanford, Carmarthenshire SA18 3SJ Tel: 01269 832220 Fax: 01269 832221 email: [email protected] www.quinshield.com Quinshield ® ® Versatility As a result of innovative research, design and manufacturing techniques, Quinshield is able to provide an infinite variety of features to suit many different applications and particular customer specifications. z Thermal Insulation z Natural/Forced Ventilation z Fire Resistance z Air Conditioning z Sound Proofing z Load Bearing Floor/Bases z Electrical Installation z Explosion Relief Scope By providing a high standard of quality in design, manufacture and customer service at competitive prices Quinshield has developed a strong position among its many clients in the market for GRP kiosks and buildings. The extensive range varies from small basic kiosks to large multi-feature buildings. After sales back-up plays a key part in our customer service. A first class package from design to delivery and installation. Customised Features Many optional features can be incorporated into our kiosks and buildings to provide the ideal “package for the customer”. z Mounting Boards z Partitions z Inspection Windows z Unistruts z Cable Entry ‘Cat Flap’ Doors z Gland Plates z Removable Panels z Access Hatches z Optional Locking Systems z Vents z Apertures and Cowls z Customer Logos z Pre-Installation of Customer Equipment The Traditional Range The specifications of our Traditional Range provide extensive scope for the supply of purpose built kiosks, designed to meet customer requirements, suitable for a variety of applications and widely contrasting environmental considerations. Standard Sizes WIDTH External - from 750mm in 250mm steps to 50 metres. DEPTH External - from 500mm in 250mm steps to 12 metres. HEIGHT Internal - 1200, 1400, 1650, 1900, 2150, 2300, then in 100mm steps to four metres. Other/larger dimensions can be quoted. Standard Construction Moulded in Glass Reinforced Polyester (GRP) composite construction, totally encapsulating a rigid core. GRP laminate is made from fire retardant structural polyester resin reinforced with chopped strand matt glassfibre. Standard core material is l2mm thick plywood, weather and boil proof to BS 1203. Other materials can be used to satisfy different structural/insulation requirements. Large panel areas are suitably reinforced to maintain structural stability. Designed to comply with CP 3: Chapter 5/BS 6399 part 1, 1984 wind, snow and seismic loadings and all other relevant British Standards. Standard fixing is through reinforced internal GRP flanges by expanding bolt system onto prepared bases. External flanges can be provided. Life expectancy is in excess of 30 years. Finishes External: Traditional Brick, Stone and other Textured Finishes. Choice of colours from the BS 4800 or RAL range. A coloured isophthalic resin (Gelcoat) forms the external barrier giving an excellent weather and chemical resistance in the harshest of environments. Simulated Brick and Stone wall finish and simulated wood finish doors are available in a variety of colours to blend with particular environmental and architectural backgrounds. Standard internal finish is a white fire retardant resin. Other internal finishes can be provided. Doors An extensive range of door sizes is available. Located in width or depth walls, central or offset. Stainless steel (316) hinges are fitted to all doors. Hinges are fitted with stainless steel security fasteners in such a manner that they cannot be removed from outside the kiosk. Doors and door frames have encapsulated steel reinforcements to provide stiffness and a good degree of security. Door leaves are fitted with automatic hold-open stays. Sills are protected with extruded alloy capping. The passive doorleaf of a double door is fitted with internal top and bottom spring bolts. Door Locking Standard locking is by cylinder nightlatch lock or stainless steel (Grade 316) Hasp and staple. Alternatively:- Locking to suit customer specification. Insulation Standard construction provides ‘U’ value 2.2 W/m 2 C O . Higher levels of insulation can be offered to meet building regulations or specific requirements. Fire Rating Panel construction complies with BS 476 Part 22, half hour fire resistance (Retention of stability, integrity and insulation). Fire retardant resin is used to provide self extinguishing laminates to BS 476 Part 7 Class 2 (Surface spread of flame). Other fire ratings can be provided. Sound Attenuation Standard composite core construction achieves noise attenuation of 24dBA over octave band centre frequency range of 31.5Hz to 8KHz measured at 1.0m distance from wall. Other levels of attenuation up to 50dBA nominal acoustic performance can be offered by use of different constructions. Environmental Protection Dust, weather and splash-proof to a minimum of IP 54 protection rating. Higher degrees of protection can be provided to IP 55 and IP 65. Environmental Control Adequate natural ventilation can be provided by means of integral vents, fitted with bird and vermin screens. Forced ventilation to meet specific requirements can be provided by suitable fans, complete with external weatherproof GRP cowl. Heating, air- conditioning and de-humidification can be provided. Electrics All electrical installations are in accordance with the lEE regulations current editions, encompassing domestic to Zone 1 as required. Floors/bases Several options are available, ranging from integral composite construction floors to steel channel baseframes complete with steel plate decking. Quality All manufacture and customer service is controlled by an effective quality assurance system, in line with the recommendations of BS 5750/ISO 9000. Other products Quinshield ltd also design and manufacture a comprehensive range of other products (Details on separate brochures).

Ammanford, SA18 3SJ

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

TECHNICALSPECIFICATIONTRADITIONAL

ProductsGRP

TR

AD

ITIO

NA

L

Due to our policy of maintaining a continuous review of product performance and materials ofconstruction we reserve the right to amend the design and dimensions of the products illustrated inthis publication at any time and without prior notice.

Quinshield ltdCapel HendreAmmanford,CarmarthenshireSA18 3SJ

Tel: 01269 832220Fax: 01269 832221email: [email protected]

Quinshield ltdCapel HendreAmmanford,CarmarthenshireSA18 3SJ

Tel: 01269 832220Fax: 01269 832221email: [email protected]

® ®

Versatility

As a result of innovative research, design andmanufacturing techniques, Quinshield is able to provide aninfinite variety of features to suit many different applications and particular customer specifications.

Thermal Insulation Natural/Forced VentilationFire Resistance Air ConditioningSound Proofing Load Bearing Floor/BasesElectrical Installation Explosion Relief

Scope

By providing a high standard of quality in design,manufacture and customer service at competitive pricesQuinshield has developed a strong position among itsmany clients in the market for GRP kiosks and buildings.

The extensive range varies from small basic kiosks to largemulti-feature buildings.

After sales back-up plays a key part in our customerservice. A first class package from design to delivery andinstallation.

Customised Features

Many optional features can be incorporated into ourkiosks and buildings to provide the ideal “packagefor the customer”.

Mounting Boards PartitionsInspection Windows UnistrutsCable Entry ‘Cat Flap’ Doors Gland PlatesRemovable Panels Access HatchesOptional Locking Systems VentsApertures and Cowls Customer LogosPre-Installation of Customer Equipment

The Traditional RangeThe specifications of our Traditional Range provide extensivescope for the supply of purpose built kiosks, designed to meetcustomer requirements, suitable for a variety of applications andwidely contrasting environmental considerations.

Standard SizesWIDTHExternal - from 750mm in 250mm steps to 50 metres.DEPTHExternal - from 500mm in 250mm steps to 12 metres.HEIGHTInternal - 1200, 1400, 1650, 1900, 2150, 2300, then in 100mmsteps to four metres. Other/larger dimensions can be quoted.

Standard ConstructionMoulded in Glass Reinforced Polyester (GRP) compositeconstruction, totally encapsulating a rigid core. GRP laminate ismade from fire retardant structural polyester resin reinforced withchopped strand matt glassfibre.Standard core material is l2mm thick plywood, weather and boilproof to BS 1203. Other materials can be used to satisfy differentstructural/insulation requirements. Large panel areas are suitablyreinforced to maintain structural stability.Designed to comply with CP 3: Chapter 5/BS 6399 part 1, 1984wind, snow and seismic loadings and all other relevant BritishStandards. Standard fixing is through reinforced internal GRPflanges by expanding bolt system onto prepared bases. Externalflanges can be provided. Life expectancy is in excess of 30 years.

FinishesExternal: Traditional Brick, Stone and other Textured Finishes.Choice of colours from the BS 4800 or RAL range.A coloured isophthalic resin (Gelcoat) forms the external barriergiving an excellent weather and chemical resistance in theharshest of environments. Simulated Brick and Stone wall finishand simulated wood finish doors are available in a variety ofcolours to blend with particular environmental and architecturalbackgrounds.Standard internal finish is a white fire retardant resin. Otherinternal finishes can be provided.

DoorsAn extensive range of door sizes is available. Located in width ordepth walls, central or offset.Stainless steel (316) hinges are fitted to all doors. Hinges arefitted with stainless steel security fasteners in such a manner thatthey cannot be removed from outside the kiosk. Doors and doorframes have encapsulated steel reinforcements to providestiffness and a good degree of security. Door leaves are fitted withautomatic hold-open stays. Sills are protected with extruded alloycapping. The passive doorleaf of a double door is fitted withinternal top and bottom spring bolts.

Door LockingStandard locking is by cylinder nightlatch lock or stainless steel(Grade 316) Hasp and staple.Alternatively:- Locking to suit customer specification.

InsulationStandard construction provides ‘U’ value 2.2 W/m2CO. Higherlevels of insulation can be offered to meet building regulations orspecific requirements.

Fire RatingPanel construction complies with BS 476 Part 22, half hour fire resistance (Retention of stability, integrity and insulation).Fire retardant resin is used to provide self extinguishing laminates toBS 476 Part 7 Class 2 (Surface spread of flame). Other fire ratingscan be provided.

Sound AttenuationStandard composite core construction achieves noise attenuation of24dBA over octave band centre frequency range of 31.5Hz to 8KHzmeasured at 1.0m distance from wall. Other levels of attenuation upto 50dBA nominal acoustic performance can be offered by use of different constructions.

Environmental ProtectionDust, weather and splash-proof to a minimum of IP 54 protection rating.Higher degrees of protection can be provided to IP 55 and IP 65.

Environmental ControlAdequate natural ventilation can be provided by means of integralvents, fitted with bird and vermin screens. Forced ventilation tomeet specific requirements can be provided by suitable fans,complete with external weatherproof GRP cowl. Heating, air-conditioning and de-humidification can be provided.

ElectricsAll electrical installations are in accordance with the lEE regulationscurrent editions, encompassing domestic to Zone 1 as required.

Floors/basesSeveral options are available, ranging from integral compositeconstruction floors to steel channel baseframes complete withsteel plate decking.

QualityAll manufacture and customer service is controlled by an effectivequality assurance system, in line with the recommendations ofBS 5750/ISO 9000.

Other productsQuinshield ltd also design and manufacture a comprehensiverange of other products (Details on separate brochures).

The ProductThe Traditional Range of GRP kiosks andbuildings offers a practical, swift and economicalternative to more costly and complexconventional building materials and methods.

The many advantages of GRP compositeconstruction are ideally combined with atraditional appearance to blend with thesurrounding environment and local architecture.

QB1 RED QB2 RUSSET QB3 GREY QB4 DARK BROWN QB5 LIGHT BROWN QB6 BUFF

QS1 LIGHT GREY QS2 BUFF QS3 DARK GREY

BRICK FINISH RANGE

STONE FINISH RANGE

AdvantagesOur GRP kiosks and buildings are designed and manufacturedto provide the most effective and economic solution tocustomer requirements.

Environmentally friendly simulated traditional exterior finishes.Choice of colours.Extensive scope of size options.Good aesthetic appearance.Superior quality at competitive prices.Durability and long service life.Maintenance free materials.Designed to withstand wind, snow and seismic loadings.Weather and corrosion resistance.Robustness and security.Purpose built features.Versatility to suit customer needs and different locations.Speed of delivery and installation by a specialist supplier.Easy to relocate and extend.Reduction in site costs compared to conventional building methods.

External FinishMaintenance free, GRP (Glass Reinforced Polyester) compositesare used to create a cost effective, environmentally compatibleand versatile alternative to conventional buildings. A variety offinishes is available to suit particular locations and customerpreferences.

Simulated Brick RoughcastSimulated Stone RenderedTextured Simulated Wood DoorsPebble Dash Textured Flat RoofsSimulated Slate Pitched Roofs

A choice of simulated brick or stone finishes is offered from ourstandard range. Other colours can be specially provided onrequest to suit particular situations.

All other finishes are available in any colour from the BS 4800range or RAL range.

ApplicationsQuinshield’s GRP kiosks and buildings are suppliedthroughout the UK and overseas, servicing a widerange of clients, applications and conditions.

Typical applications include:

Switchgear AnalysersControl Equipment MetersGenerators Gas RegulatorsCompressors TransformersPumps and Valves CommunicationsStations ElectronicsSubstations Chemical TreatmentTelemetry

Delivery and InstallationA comprehensive delivery and installation service is provided.Delivery methods depend on product size and site access.

Delivery is normally ready built and offloading is by HiabVehicle subject to site access.Delivery is carried out in panel form for larger kiosks or indifficult locations, for assembly on site.For export contracts, kiosks are normally loaded intoshipping crates or containers for despatch abroad.On site installation is by our skilledand experienced specialist team.Ease of installation greatly cutsdown work and cost on site,particularly in remote situations.Close liaison is maintained withour clients to ensure effectiveorganisation of delivery andinstallation.Cranage and special handlingare used as necessary.Quinshield has the flexibility andexpertise to adapt to the particulardemand of a l l types of s i tesituations or conditions.

Quinshield®