12
Dräger X-am ® 5000 Multi-Gas Detection The Dräger X-am ® 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as O 2 and harmful concentrations of toxic gases, organic vapors, Odorant and Amine. ST-9466-2007 Retroreflective label: Easy to find in the dark or in water Dräger sensors: Fast, accurate and reliable Large display: All readings at one glance Gas inlets: At the top and the bottom for safe readings Visual alarm: 360° visible alarm

Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Embed Size (px)

Citation preview

Page 1: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Dräger X-am® 5000Multi-Gas Detection

The Dräger X-am® 5000 belongs to a generation of gas detectors,developed especially for personal monitoring applications. This 1- to 5-gasdetector reliably measures combustible gases and vapors as well as O2

and harmful concentrations of toxic gases, organic vapors, Odorant andAmine.

ST-9

466-

2007

Retroreflective label:Easy to find in the darkor in water

Dräger sensors:Fast, accurate and reliable

Large display:All readings at one glance

Gas inlets:At the top and the bottomfor safe readings

Visual alarm:360° visible alarm

Page 2: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Benefits

02 | Dräger X-am® 5000

Ergonomic mobile phone design

Despite its advanced functionality, the Dräger X-am 5000's practical mobile phone design and light weight makeit comfortable to carry. Reduced to its essentials, the two button control panel and easy to follow menu allow forintuitive use.

Flexible sensor exchange

It is easy to exchange, upgrade or calibrate the sensors to other gases. The ability to customize the Dräger X-am 5000's sensors makes more applications possible, including rental equipment.

Poison-resistant ex sensor

For improved safety when facing unknown and potentially explosive hazards – the Dräger X-am 5000 providesdependable warnings in the event of explosive atmospheres thanks to the high level of sensitivity of theinnovative catalytic Ex sensor. It not only responds quickly to explosive gases and combustible organic vapors,but is also highly resistant against sensor poisons such as silicone and hydrogen sulfide. In combination withits long term stability this offers an extraordinary long expected sensor lifetime of more than 4 years. This willreduce your operational costs.

Durable sensor technology

Equipped with durable XXS sensor technology, the Dräger X-am 5000 offers maximum security at extremely lowoperational costs. The sensor's resistance, in combination with its long term stability, provides the sensor with alifetime in excess of four years, which can help reduce your operational costs.

Robust and watertight

The Dräger X-am 5000 is water and dust resistant according to IP 67 standards. This means that the detectorremains fully functional and ready for use even after being dropped into water. The integrated rubber protectionand shock-proof sensors provide additional resistance to impact and vibration. Moreover, the Dräger X-am 5000is resistant to electromagnetic interference.

External pump

The optional external pump, which operates with a hose up to 30 (98 feet) meters long, makes it possible touse the detector for pre-entry measurements into confined spaces such as tanks, shafts, etc. The pump startsautomatically when the detector is inserted.

Page 3: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Benefits

Dräger X-am® 5000 | 03

Area monitoring

In combination with the Dräger X-zone® 5000 the gas detector can be used for various area monitoringapplications. Up to 25 Dräger X-zone 5000 units can be automatically interconnected to form a wirelessfenceline. This interconnection of the area monitoring devices allows for the fast securing of larger areas, e.g.pipelines or industrial tanks – even within the scope of industrial shutdowns.

Optimum solutions for function or bump tests and calibrations

Simple, fast and professional: from a function or bump test to complete documentation, users can choose froma range of practical, on-site solutions that offer maximum safety for every application. The automatic test and

calibration station Dräger X-dock® and the Dräger Bump Test Station are ideal system extensions that save timeand reduce workload. Fresh air, mixed gas and single gas calibrations can be done directly using the Dräger X-am 5000 menu.

Flexible power supply

The Dräger X-am 5000 can be used with the standard alkaline batteries. In addition, it can be fitted witha T4 battery that can be charged while still inside the instrument. An optional Save Energy Mode makes itpossible to increase the operating time of Dräger X-am 5000 to more than 40 hours. This is done by selecting ameasurement interval of either 1 second (the standard), 10 or 20 seconds for the CatEx sensor.

Page 4: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

System components

04 | Dräger X-am® 5000

D-1

2191

-201

0

DrägerSensor XXS

A small sensor - a giant step into the future: The new DrägerSensorXXS range is remarkably compact, and boasts an even higherperformance than the competition.

D-3

1728

-201

1

Dräger Catalytic Ex-Sensors

Multiple gases at the same time: The DrägerSensor Cat Ex measurescombustible gases and vapors in the air.

ST-

740-

2006

Dräger Bump Test Station

Easy to use, stand-alone and portable. With the Bump Test Station,functionality tests of gas detection and warning devices can be carriedout easily and quickly.

Page 5: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Accessories

Dräger X-am® 5000 | 05

ST-

9477

-200

7

Dräger X-am 125, external pump

External pump for hose length of up to 30 meters (98 feet). Makes itpossible to use the detector for pre-entry measurements into confinedspaces such as tanks, shafts, etc. The pump starts automatically whenthe detector is inserted. The change between diffusion and pumpoperation is quickly and easily possible without any need for additionaltools or steps.

D-1

2284

-200

9

Power pack & Charging set

Consisting of: NiMH power supply, charging module, single charger

ST-

1501

1-20

08

Leather carrying case

ST-

1436

0-20

08

Calibration cradle

Page 6: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Accessories

06 | Dräger X-am® 5000

ST-

5080

-200

5

Calibration gas and accessories

Calibration of equipment will ensure safe operation and functionalityof equipment and will also meet with the applicable regulations andcodes of practice. Various calibration options are available to providethis facility.

D-3

0746

-201

5

Dräger Configuration and Evaluation Software

Save measurement results, professionally configure gas detectioninstruments and viewing performance data – all that is possible withthe tailor-made Dräger software.

Related Products

D-2

7784

-200

9

Dräger X-am® 5600

Featuring an ergonomic design and innovative infrared sensortechnology, the Dräger X-am 5600 is the smallest gas detectioninstrument for the measurement of up to 6 gases. Ideal for personalmonitoring applications, this robust and water-tight detector providesaccurate, reliable measurements of explosive, combustible and toxicgases and vapors as well as oxygen.

Page 7: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Related Products

Dräger X-am® 5000 | 07

ST-

67-2

006

Dräger X-am® 7000

Dräger X-am® 7000 is the solution for the simultaneous andcontinuous measurement of up to five gases. It is the ideal companionin a variety of applications where the reliable detection of oxygen, toxicand combustible gases and vapors are necessary.

Page 8: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Technical Data

08 | Dräger X-am® 5000

Dimensions (W x H x D) 48 x 130 x 44 mm; 1.89 x 5.12 x 1.73 in.

Weight 220 - 250 g; 7.8 - 8.8 oz.

Temperature -20 - +50 °C; -4 - 122 °F

Pressure 700 - 1,300 hPa

Ambient conditions

Humidity 10 - 95% r.h.

Visual 360°

Audible Multi-tone > 90 dB at 30 cm

Alarms

Vibrating

Ingress Protection IP 67

Operating time > 12 hours with Alkaline and NiMH; > 13 hours with NiMH HC; without Ex Sensor typ. > 250 hours

with Alkaline Battery; when using the Save Energy Mode > 40 hours

Charging time < 4 hours

Data logger Can be read out via Infrared > 1,000 hours with 5 gases and a recording interval of 1 value per

minute

Pump operation Maximum hose length 30 m; 98 ft.

I M1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2 Ex d ia I Mb, II 2G Ex d

ia IIC T4 / T3 Gb

Performance approval to:

ATEX

EN 50104 (2002) + A1 (2004)

EN 45544

EN 60079-29-1:2007

EN 50271:2010

O2

CO & H2S

Methane to nonane

Software and documentation

CSA Class I, Div. 1 Group A, B, C, D T.-Code T4 / T3

IECEx Ex ia I

Ex ia IIC T3

Ex d ia I

Ex d ia IIC T4/T3

CE-mark Electromagnetic compatibility Directive 2004 / 108 / EG; EN

50270:2006

MED Marine Equipment Directive 96 / 98 / EC

Approvals

MSHA

Ordering Information

Dräger X-am® 5000 2)

Consisting of: basic instrument with an integrated data logger and

manufacturer's and calibration certificates.

A functional instrument must include up to 4 sensors and a power

supply unit.

83 20 000

Description Measuring range Resolution Response time (t90) Order code

CatEx 125 PR2) 0 - 100 % LEL

0 - 100 Vol.-% CH4

1 % LEL 10 sec. 68 12 950

CatEx 125 PR Mining 0 - 100 % LEL

0 - 100 Vol.-% CH4

1 % LEL 10 sec. 68 13 080

DrägerSensor XXS O2 2) 0 - 25 Vol.-% 0.1 Vol.-% 10 sec. 68 10 881

DrägerSensor XXS CO2) 0 - 2,000 ppm 2 ppm 15 sec. 68 10 882

DrägerSensor XXS CO

LC

0 – 2,000 ppm 1 ppm 15 sec. 68 13 210

DrägerSensor XXS CO

HC

0 - 10,000 ppm 5 ppm 25 sec. 68 12 010

Page 9: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Ordering Information

Dräger X-am® 5000 | 09

DrägerSensor XXS CO /

H2 compensated

0 - 2,000 ppm CO 2 ppm 25 sec. 68 11 950

DrägerSensor XXS H2S 0 - 200 ppm 1 ppm 15 sec. 68 10 883

DrägerSensor XXS H2S

LC2)

0 - 100 ppm 0.1 ppm 15 sec. 68 11 525

DrägerSensor XXS H2S

HC

0 - 1,000 ppm 2 ppm 15 sec. 68 12 015

DrägerSensor XXS CO /

H2S

0 - 2,000 ppm CO / 0 -

200 ppm H2S

1 ppm H2S / 2 ppm CO 20 sec. 68 11 410

DrägerSensor XXS NO 0 - 200 ppm 0.5 ppm 10 sec. 68 11 545

DrägerSensor XXS NO2 0 - 50 ppm 0.1 ppm 15 sec. 68 10 884

DrägerSensor XXS NO2

LC

0 - 50 ppm 0.02 ppm 15 sec. 68 12 600

DrägerSensor XXS SO2 0 - 100 ppm 0.1 ppm 15 sec. 68 10 885

DrägerSensor XXS PH3 0 - 20 ppm 0.01 ppm 10 sec. 68 10 886

DrägerSensor XXS PH3

HC

0 - 2,000 ppm 1 ppm 10 sec.* 68 12 020

DrägerSensor XXS HCN 0 - 50 ppm 0.1 ppm 10 sec.* 68 10 887

DrägerSensor XXS HCN

PC

0 – 50 ppm 0,5 ppm 10 sec.* 68 13 165

DrägerSensor XXS NH3 0 - 300 ppm 1 ppm 10 sec.* 68 10 888

DrägerSensor XXS CO2 0 - 5 Vol.-% 0.1 Vol.-% 30 sec.* 68 10 889

DrägerSensor XXS CI2 0 - 20 ppm 0.05 ppm 30 sec. 68 10 890

DrägerSensor XXS H2 0 - 2,000 ppm 5 ppm 10 sec. 68 12 370

DrägerSensor XXS H2

HC

0 - 4 Vol.-% 0.01 Vol.-% 20 sec. 68 12 025

DrägerSensor XXS OV 0 - 200 ppm 0.5 ppm 20 sec.* 68 11 530

DrägerSensor XXS OV-A 0 - 200 ppm 1 ppm 40 sec.* 68 11 535

DrägerSensor XXS

Amine

0 - 100 ppm 1 ppm 30 sec. 68 12 545

DrägerSensor XXS

Odorant

0 - 40 ppm 0.5 ppm 90 sec. 68 12 535

DrägerSensor XXS

COCl2

0 - 10 ppm 0.01 ppm 20 sec.* 68 12 005

DrägerSensor XXS Ozon 0 - 10 ppm 0.01 ppm 10 sec.* 68 11 540

1)Special calibration for Ex sensors are available (standard setting: Methane)2) Dräger provides a 3 year guarantee on the Dräger X-am® 5000 and these sensors. The legal rights arising from defects remain

unaffected.* Response time (t50)

Sensors with a 5 year

warranty

DrägerSensor XXS E

CO

0 - 2,000 ppm 2 ppm 15 sec. 68 12 212

DrägerSensor XXS E

H2S

0 - 200 ppm 1 ppm 15 sec. 68 12 213

DrägerSensor XXS E O2 0 - 25 Vol.-% 0.1 Vol.-% 10 sec. 68 12 211

Power supply units

NiMH power pack T4 83 18 704

Power pack & charging set

Consisting of: rechargeable NiMH power supply T4, charging

module and a single charger (for worldwide use)

83 18 785

Page 10: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Ordering Information

10 | Dräger X-am® 5000

NiMH power supply T4 high capacity 83 22 244

Alkaline power pack T3 / T4 (without alkaline batteries) 83 22 237

Alkaline batteries T4 (2 pc.) for alkaline power supply 83 22 237 83 22 240

Alkaline batteries T3 (2 pc.) for alkaline power supply 83 22 237 83 22 239

Charging accessories

Charging module 83 18 639

Charging set basic consisting of one charging module and a

single power supply (worldwide use)

83 20 333

Power supply with connection cable (worldwide use) for max. 20

charging modules

83 15 805

Single charger (worldwide use) for max. 5 charging modules 83 16 994

Single charger (worldwide use) for max. 2 charging modules 83 15 635

Car charging connection cable 12 / 24 V for a charging module 45 30 057

Vehicle charger mounting kit for a X-am® 1/2/5x00 car charging

module

83 18 779

Pump accessories

Dräger X-am® 1/2/5x00 external pump 83 19 400

Hand pump adapter 83 19 195

Confined space entry set, with an external pump and 3m hose 83 19 399

Carrying case Dräger X-am® 1/2/5x00 external pump, without

content

83 19 385

Calibration accessories

Calibration cradle for X-am® 1/2/5x00 83 18 752

Dräger X-dock® for Dräger X-am® 1/2/5x00, not including gas

cylinder

83 21 880

Dräger Bump Test Station for Dräger X-am® 5000, not including

gas cylinder

83 19 131

Dräger Bump Test Station for Dräger X-am® 5000, complete with

one test gas cylinder 58L (gases and concentration variable)

83 19 130

Nonane Checker for Dräger X-am® 5000 83 20 080

Communication accessories

Dräger GasVision 83 14 034

Dräger CC-Vision Freeware

USB DIRA with USB cable, communication adapter infrared to

USB

83 17 409

Cases

Leather carrying case 83 18 755

Carrying case for charging accessories, probes, external pump,

hose and gas cylinder (without content)

83 20 467

Area Monitoring1)

Dräger X-zone® 5000 868 MHz, 12 Ah 83 20 740

Dräger X-zone® 5000 868 MHz, 24 Ah 83 20 741

Dräger X-zone® 5000 868 MHz, 12 Ah, integrated pump 83 20 742

Dräger X-zone® 5000 868 MHz, 24 Ah, integrated pump 83 20 743

1) Further versions (915 MHz, 433 MHz, 429 MHz) available on request

Page 11: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Notes

Dräger X-am® 5000 | 11

Page 12: Amine. Multi-Gas Detection and harmful concentrations of · PDF fileDräger X-am® 5000 Multi-Gas Detection The Dräger X-am® 5000 belongs to a generation of gas detectors, developed

Notes

12 | Dräger X-am® 5000

CORPORATE HEADQUARTERS

Drägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germanywww.draeger.com

REGION EUROPE CENTRALAND EUROPE NORTH

Dräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]

REGION EUROPE CENTRALAND EUROPE NORTH

Dräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]

REGION EUROPE SOUTH

Dräger Safety France SAS25, rue Georges Besse92182 Antony CedexTel +33 1 46 11 56 00Fax +33 1 40 96 97 [email protected]

REGION MIDDLE EAST, AFRICA

Dräger Safety AG & Co. KGaABranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 [email protected]

REGION ASIA PACIFIC

Draeger Safety Asia Pte Ltd25 International Business Park#04-20/21 German CentreSingapore 609916Tel +65 6308 9400Fax +65 6308 [email protected]

REGION CENTRALAND SOUTH AMERICA

Dräger Panama S. de R.L.Complejo Business Park,V tower, 10th floorPanama CityTel +507 377 9100Fax +507 377 [email protected]

Locate your RegionalSales Representative at:www.draeger.com/contact

90

46

318

| 1

5-0

4-6

| C

om

mun

icat

ions

& S

ales

Mar

keti

ng |

PP

| L

E |

Pri

nted

in

Ger

man

y |

Chl

ori

ne-f

ree

– e

nvir

onm

enta

lly c

om

pat

ible

| S

ubje

ct t

o m

od

ific

atio

ns |

© 2

015

Drä

ger

wer

k A

G &

Co

. K

GaA