Upload
hacong
View
214
Download
2
Embed Size (px)
Citation preview
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.�
REBCO ALUMINUM WINDOWSWhen you are looking for the perfect windows to enhance your building's facade, you can count on REBCO's experienced staff to assist you with product selection and design as well as helping you with any other information you may need. Since 1952, REBCO has been providing that kind of expertise and dependable service that glaziers, storefront contractors, and architects have come to rely on.
Rebco Windows offer a pleasing sightline and can be fab-ricated in unlimited configurations and combinations of fixed, casement, hopper and vent styles. When your project requires commercial windows with special color appeal, energy savings and style, REBCO is the perfect choice. Our windows feature heavy duty corner keys with mitred corners, superior white bronze hardware and double weather-strip-ping in thermal and non-thermal configurations.
Our ability to fabricate to your custom specifications is unparalleled. When it comes to selection . . .
REBCO's in Front !
SERIES 20002" Therma-Barrier
Projected & Casement Windows
REBCO's 2000 Series Window has been specifically designed with economy, convenience of instal-lation and the REBCO trademark of quality in mind. Both Series 2000 & Series 25000 Windows combine superior construction for durability and ease of operation with the energy economy and all-weather comfort of the Therma-Barrier thermal barrier system.
REBCO THERMA-BARRIER Windows feature:• Exclusive use of 4-Bar Hinges. • Polyurethane thermal barrier.• 3/8" Heavy Duty Corner keys. • Double Weather-stripping between sash and frame.• Snap on glazing beads for 1/4", 5/8" or 1" Glazing.• White Bronze Hardware.• Mitred Corners on sashes.
SERIES 250002-1/2" Therma-Barrier
Projected & Casement Windows
For the ultimate in a high strength, operable window, choose the 25000 Series. Both REBCO's 25000 Series and 2000 Series Windows feature a special thermal insulation in extruded aluminum perim-eters and mullions which creates a defensive barrier against heat loss and condensation. When combined with insulating glass, there is a marked reduction in condensation on both glazing frames.
THERMA-BARRIER windows are available in Duranodic, clear anod-ized and white or brown baked acrylic finishes to give you an ideal combination of styling, energy savings and maximum comfort.
SERIES 2000 SPECIFICATIONSTest Reports available upon request
GENERAL — Furnish and install REBCO Series 2000 insulated alumi-num windows as manufactured by REBCO Incorporated, Paterson, NJ. The windows shall include the necessary hardware and related items as described in this section and as detailed on the plans.
SHOP DRAWINGS — REBCO shop drawing services are available. Please call for details.
MATERIALS — The windows shall be fabricated from extruded aluminum alloy 6063-T5. All members shall be a minimum 2" in depth. All sash sections shall be tubular extrusions with a minimum 1/8" in combined wall sections. Glazing beads shall have a thickness of not less than .045". Window sections shall have a minimum glazing leg of .70" and they shall be provided with snap-on aluminum glazing beads. (cont. on reverse side)
SERIES 25000 SPECIFICATIONSTest Reports available upon request
GENERAL — Furnish and install REBCO Series 25000 insulated alumi-num windows as manufactured by REBCO Incorporated, Paterson, NJ. The windows shall include the necessary hardware and related items as described in this section and as detailed on the plans.
SHOP DRAWINGS — REBCO shop drawing services are available. Please call for details.
MATERIALS — The windows shall be fabricated from extruded aluminum alloy 6063-T5. All members shall be a minimum 2-1/2" in depth. All frame and vent sections shall be tubular extrusions with a minimum 3/16" in combined wall sections. Glazing beads shall have a thickness of not less than .045". Window sections shall have a minimum glazing leg of 3/4" and they shall be provided with snap-on aluminum glazing beads.
CONSTRUCTION — Frame corners shall be machine cut for precision fit and butt jointed and mechanically fastened using stainless steel fasteners. (cont. on reverse side)
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
�
SPECIFICATIONS
SERIES 2000 (cont.)CONSTRUCTION — Frame corners shall be machine cut for precision fit and butt jointed and mechanically fastened us-ing stainless steel fasteners. Sash corners shall be mitred and mechanically crimped and epoxy glued under several tons of pneumatic force. Muntin bars shall be coped to create a mortised joint which shall be argon-electric welded to insure maximum strength.
WEATHER-STRIP — The operating vent shall be double weather-stripped with an extruded vinyl. The weather-strip shall be uninterrupted and secured within extruded race-ways at the interior and exterior points of contact with the surrounding frame.
HARDWARE — Projected windows shall be provided with two 4-bar hinge assemblies securely fastened to the frame and vent, and operating in a track provided with an ad-justable nylon friction feature. The cam handles shall be manufactured from white bronze and secured with stainless steel fasteners. Casement windows shall be supported by butt hinges manufactured from white bronze and secured with stainless fasteners. Casements shall have white bronze locking handles with concealed strikes. Locking handles and concealed strikes shall be securely fastened with stainless steel fasteners.
FINISH — The material for this series is available and stocked in a white painted finish, clear anodized and dark bronze hardcoat. Custom colors available. Call for details.
THERMAL BARRIER — The thermal barrier shall consist of a two-part, chemically-curing, high strength, pure polyurethane casting resin. This thermal barrier shall provide a continu-ous uninterrupted break around the entire perimeter of the frame and vent and it shall not be abridged by any metals, conductors or other similar materials. The cavity size of the thermal break shall be .437" wide, .350" high and shall have a throat opening of at least .188" wide. Residential size cavi-ties will not be permitted.
INSTALLATION — Windows shall be installed by experienced window erectors, in accordance with local building codes. All members shall be set plumb and level with ventilators in true alignment. All aluminum surfaces in contact with masonry or steel shall be insulated therefrom by pressure sensitive tape, zinc chromate primer, lacquer or bituminous paint.
SERIES 25000 (cont.) Sash corners shall be mitred and mechanically crimped and epoxy glued under several tons of pneumatic force. Muntin bars shall be coped to create a mortised joint which shall be argon-electric welded to insure maximum strength.
WEATHER-STRIP — The operating vent shall be double weather-stripped with an extruded vinyl. The weather-strip shall be uninter-rupted and secured within extruded raceways at the interior and exterior points of contact with the surrounding frame in a manner that shall provide for easy weather-strip replacement.
HARDWARE — Projected windows shall be provided with two 4-bar concealed hinge assemblies securely fastened to the frame and vent, and operating in a track provided with an adjustable nylon friction feature. The cam handles shall be manufactured from white bronze and secured with stainless steel fasteners. Case-ment windows shall be supported by butt hinges manufactured from white bronze and secured with stainless fasteners. Casements shall have white bronze locking handles with concealed strikes. Locking handles and concealed strikes shall be securely fastened with stainless steel fasteners.
FINISH — The material for this series is available and stocked in a white painted finish, clear anodized and dark bronze hardcoat. Custom colors available. Call for details.
THERMAL BARRIER — The thermal barrier shall consist of a two-part, chemically-curing, high strength, pure polyurethane casting resin. This thermal barrier shall provide a continuous uninterrupted break around the entire perimeter of the frame and vent and it shall not be abridged by any metals, conductors or other similar materials. The cavity size of the thermal break shall be .744" wide, .350" high and shall have a throat opening of at least .312" wide. Residential size cavities will not be permitted.
INSTALLATION — Windows shall be installed by experienced window erectors, in accordance with local building codes. All members shall be set plumb and level with ventilators in true align-ment. All aluminum surfaces in contact with masonry or steel shall be insulated therefrom by pressure sensitive tape, zinc chromate primer, lacquer or bituminous paint.
PROTECTION AND CLEANING — Upon completion of erection, windows will be left in a clean condition. Protection against dam-age by others and finish cleaning shall be the responsibility of the general contractor.
REBCO reserves the right to change its specifications, without notice, if deemed necessary in the evolution of its products.
REBCO warrants that the goods to be supplied will conform to the catalog or price list description. This waRRanTy is in liEu Of all OThER waRRanTiEs OR guaRanTEEs, ExpREss OR impliEd, in-Cluding ThE impliEd waRRanTiEs as TO mERChanTaBiliTy OR as TO ThE fiTnEss fOR any paRTiCulaR usE OR puRpOsE and REBCO shall nOT BE liaBlE fOR any lOss, damagE OR COsTs, diRECTly OR indiRECTly, aRising fROm ThE usE Of suCh gOOds, OR fOR COnsEquEnTial, inCidEnTial, spECial, ExEmplaRy OR puniTivE damagEs.
it is the sole responsibility of the customer to confirm with their own architect, engineer or other professional consultants that the goods offered for sale by REBCO meet the requirements and specifications of the particular project and use for which they are being purchased. any advice received by a customer from REBCO's representatives or employees is not guaranteed or war-ranteed since REBCO does not and cannot determine whether the goods comply with the requirementas nd specifications of the ultimate user nor does REBCO control or supervise the suse-quent fabrication or installation of its goods or their use after sale. REBCO ExpREssly disClaims any waRRanTiEs OR guaRanTEEs ThaT ThE gOOds will mEET ThE nEEds and/OR REquiREmEnTs Of ThE ulTimaTE usERs Of ThE gOOds.
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.�
HARDWARE
25 -107L or 25 -107RCasement Window Roto Operator & Handle (Handed)
25 -108Concealed Keeper for use with P.I. hopper handles 25 -108L, 25-108R and 25 -109H
25 -106L or 25 -108RCam Handle for project-in hoppers
25 -101Strikeused with P.O. vent handles 25-103L, 25-103R and 25 -109
25 -103L or 25 -103RCam Handle for project out vents
25-102Casement Window Locking Handle 25-104
ConcealedKeeperfor 25-102 and 25-120
25 -120Duplex Lock Top Assembly used for one step double locking system for casement window
25 -111Custodial
Lock Handle & Key used to open &
close custodial locks
25 -109HHopperCustodial Lock used with securitylock handle (Note: Used with Concealed Keeper 25 -108)
25 -109Vent Custodial Lock used with security lock handle (Note: Usedwith strike 25 -101)
25 -107CG – Channel Guide used with roto operator
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
�
HARDWARE
25 -115Under Screen Roto Operator & Handle
used on vent window with roto operator
(30" min.windowwidth)
4 -10, 4 -12, 4 -16,4 -20, 4 -24, 4 -284 Bar Friction Hingeused in vent & hopper windows
25 -15CGChannel Guide (2 pieces required)
used with under screen roto operator
25 -113 Limit Arm used to limit opening of window
25-117Pole Tipused to open & closepole type cam handles
25-114CPull Ringused to open & close hopper window with pole handle in one step (used in conjunction with Pole Type Cam Handles on windows 48" & over)
25-112CasementButt Hingeused incasementwindow
25-114L or 25-114RHopper Pole Handleused on hopper windowsto open & close (Handed)
25-1166' Window
Pole (Aluminum Shaft)used to open & close
pole type cam handles
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.�
1.6875"
1"
20-011
1.5"
1.5"
1.5"
1.5"
20-001
20-00920-809
1"1.6875"
20-211
2.125"
.75"
20-802
1.4375"
20-801
1.4375"2"
20-216
1.3125"
1.438"
1.438"
20
00
SER
IES
2" WINDOW SECTIONS
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
�
2" WINDOW SECTIONS
2.1875".75"
20-002
.75" 2.1875"
20-202
1.3125"
2"
20-006
.75"
1.5"
20-008
20-611For 1/4" Glass
20-658For 5/8" Glass
20-600For 1" Glass
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.�
20
00
SER
IES
2" WINDOW SECTIONS
.625"1.75"
20-208
20-501
20-STIF-O
.5625"
1.181"
1.1875"
1.525"
1.0625"
20-275 2-PIECE RECEPTOR(Head and Jamb)
.375"
.625"
2.1875"
20 -275G11 -275F
3"
20-301
2-PIECE MULLION
11-300Cover
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
�
2" WINDOW SECTIONS1
HOPPER2
1
2DOUBLE HOPPER
11a11
3
4DOUBLE VENT
1212a
17
3
20
18 19
21CASEMENTW/FIXED LITE
10
4 STACK VENTS
6
CLASSROOM W/FIXED LITE
5
16
13
2 14
151
9
2 STACK HOPPERS
6
5
CLASSROOM HOPPER
2 21
20
CASEMENT
CLASSROOM VENT
8
8
3
VENT4
7
6
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.�
20
00
SER
IES
2" WINDOW SECTIONS
20-011
20-801
20-600
20-600
20-809
20-011
20-501
SECTION 1
SECTION 2
20-211
20-802
20-600
SECTION 3
20-600
20-802
20-211
SECTION 4
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
�0
2" WINDOW SECTIONS
20-011
20-801
20-600
20-600
SECTION 5
20-600
SECTION 6
20-002
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
20
00
SER
IES
2" WINDOW SECTIONS
20-802
20-600
20-600
SECTION 7
20-009
20-802
20-600
20-011 20-008
SECTION 8
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2" WINDOW SECTIONS
20-801
20-600
SECTION 9
20-002
20-801
20-600
20-501
20-802
20-600
SECTION 10
20-802
20-600
20-009
20-008
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
2" WINDOW SECTIONS
20-801
20-STIF(if required)
20-600
SECTION 11a
20-801
20-600
20-011 20-006
20-801
20-600
SECTION 11
20-002
20-801
20-600
20
00
SER
IES
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2" WINDOW SECTIONS
20-600
20-600
20-802
20-211SECTION 12a
20-802
20-216
20-600
20-802
20-202
20-802
20-600
SECTION 12
20-STIF(if required)
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
20
00
SER
IES
2" WINDOW SECTIONS
20-011
20-600
SECTION 14
20-600
20-600
SECTION 13
20-002
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2" WINDOW SECTIONS
20-600
20-80120-011
SECTION 16
20-600
20-006
20-011
20-600
SECTION 15
20-600
20-006
20-STIF(if required)
20-STIF(if required)
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
20
00
SER
IES
2" WINDOW SECTIONS
20-600
20-802
SECTION 19
20-011
SECTION 18
20-600
20-006
20-802
20-600
20-011
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2" WINDOW SECTIONS
20-600
20-802
SECTION 20
20-011
20-600
20-802
SECTION 21
20-011
20-600
SECTION 17
20-011
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
2-1/2" WINDOW SECTIONS
25-011S
2.125"
25-002S
25-009S
2.125"
25-809
1.5"
25-801
1.5"
1.5"
.875"
1.5"
2.5"
1.5"
1.5"
1.5"
25
00
0 S
ER
IES
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
�0
2-1/2" WINDOW SECTIONS
25-211S
2.125"
25-202S
2.125".875"
1.5"
25-208
.250"1.25"
25-0081.5"
25-275 Receptor
1.0
62
"
2.75"
25-275G11-275F
.375"
25-240
2.25"
1.5"
ZERO MULLION
25-011S
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
25
00
0 S
ER
IES
2-1/2" WINDOW SECTIONS
3"
11-300Cover
25-301
2-PIECE MULLION
4.250"
11-305Cover
25-802
2.125" .875"
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2-1/2" WINDOW SECTIONS
25-600For 1" Glass
25-658For 5/8" Glass
11-501
For maximum weather-tightness, a continuous toe bead or heel bead of sealant should be installed
INSTALLATION SEQUENCE: 1) Windows shall be inspected prior in installation of units into prepared openings on the job site, making sure no damages occurred in transportation, or in storage. All butt and miter joints must be sealed prior to glazing. Sash and framing members are to be checked prior to glazing to make sure openings are square, plum and secure to maintain face and edge clearance. All ventilators and operating sash must be properly adjusted and glazed in the closed position. Surfaces that the tape will contact should be wiped with a suitable solvent to remove any oil deposits, dirt, dust, loose mortar, or any other foreign matter.
2) REBCO, Inc. recommends applying Tremco's Polyshim II Tape, uniformly recessed 1/32" below the site line of the window. Pleasefollowtheglazingtape/gasketinstallation instructionsfoundonTremco'swebsite: www.TREMCOSEALANTS.COM
3) Be sure to daub butted tape joints with sealant to ensure a continuous exterior seal.
4) Apply corner bead of compatible sealant at each corner.
5) Place setting blocks per glass manufacturers requirements.
6) Set glass. Press firmly into tape.
7) Install removable stop.
8) Install Poly-Wej Gasket provided by REBCO, Inc.
Good glazing practices prevail. Refer to Tremco's website for instruction for glazing windows with Polyshim II Tape.
POLY-WEJ GLAZING SYSTEM
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
25
00
0 S
ER
IES
2-1/2" WINDOW SECTIONS1
HOPPER2
5
16
20
21
CASEMENT W/FIXED LITE
CLASSROOM W/FIXED LITE
10 11
13
12
9
1
2
STACK HOPPER
7
14
CLASSROOM HOPPER
217
16
CASEMENT
4
VENT5
19
174
5
STACK VENTS
4
22
2
1
15
DOUBLE VENT
DOUBLE HOPPER
78
3
18
6
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2-1/2" WINDOW SECTIONS
25-011S
25-809
11-501
SECTION 1
SECTION 2
25-600
25-600
25-011S
25-801
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
25
00
0 S
ER
IES
25-801
25-809
11-501
SECTION 3
25-600
25-600
25-002S
2-1/2" WINDOW SECTIONS
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2-1/2" WINDOW SECTIONS
SECTION 4
25-600
25-211S
25-802
25-802
SECTION 5
25-600
25-211S
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
25
00
0 S
ER
IES
2-1/2" WINDOW SECTIONS
25-O09S
25-600
SECTION 6
25-600
25-008
25-802
25-802
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2-1/2" WINDOW SECTIONS
25-011S
SECTION 7
25-600
SECTION 8
25-600
25-002S
25-600
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
25
00
0 S
ER
IES
25-600
SECTION 10
25-600
25
-80
2
25-600
SECTION 9
25
-00
8
25-011S
25-009S
25-802
2-1/2" WINDOW SECTIONS
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
�0
2-1/2" WINDOW SECTIONS
25-600
25-802
SECTION 12
25-008
SECTION 11
25
-00
8 25-60025-600
25-011S
25-0
02S
25
-80
2
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
25
00
0 S
ER
IES
2-1/2" WINDOW SECTIONS
SECTION 13
25-600
25-600
25-801
SECTION 14
25-600
25-600
25-002S
25-002S
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2-1/2" WINDOW SECTIONS
SECTION 15
25-002S
25-600 25-600
25-600
SECTION 16
25-011S
25-802
25
-80
1
25
-80
1
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
25
00
0 S
ER
IES
2-1/2" WINDOW SECTIONS
25-600
SECTION 17
25-011S
SECTION 18
25-208
25-600
25-600
25-002S
25-802
25-802
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
2-1/2" WINDOW SECTIONS
25-600
SECTION 21
25-208
25-600
SECTION 19
25-208
25-600
SECTION 2025-011S
25-011S
25-011S
25-802
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
25
00
0 S
ER
IES
2-1/2" WINDOW SECTIONS
SECTION 22
25-600 25-600
25-80225-802
25-2
02S
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
HOPPER SCREEN INSTALLATION
Spring bolt
Stainless SteelRetainer clips(4 supplied)
Male hanger
42-252 Neoprene foroperating sash
42-252Neoprenefor operating sash
Glass setting block,
by others
1/8" x 1/2" polyshim
tape, by othersRoll in vinylsupplied by Rebco
Wood blocking,by others Erection screw
with anchor as required by field conditions,by others
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118
© 8/2007, Rebco, Inc.��
18 x 16 Mesh Alclad Aluminum
AluminumSpline
Swivel Clip
AluminumMachine Screw
7/16" x 3/4" x .024" Thick Aluminum Frame Rolled Section Aluminum
CASEMENT SCREEN INSTALLATION
1171 - 1225 Madison Avenue, P.O. Box 2248, Paterson, NJ 07509 - 2248Outside NY/NJ 800 - 777 - 0787 • NJ 973 - 684 - 0200 • NY 212 - 736 - 6435 • FAX 973 - 684 - 0118© 8/2007, Rebco, Inc.
��
10 X 24 Machined Screw(4 Supplied)
Aluminum Spline
#640 "C" clip(4 Supplied)
1-1/4"Aluminum
Frame
VENT SCREEN INSTALLATION