Alcatel-Lucent GSM
9153 OMC-R Alarm Dictionary
OMC Document
Reference Guide
Release B10
3BK 21205 AAAA PCZZA Ed.05
Status RELEASED
Short title 9153 OMC-R Alarm Dictionary
All rights reserved. Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel-Lucent.
BLANK PAGE BREAK
2 / 182 3BK 21205 AAAA PCZZA Ed.05
Contents
ContentsPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2 Alarm Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.2.1 Alarm Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2.2 Alarm Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.2.3 Impact on System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.2.4 Corrective Action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 Communications Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.1 Internal Link Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.2 OMC-BSC Link Failure: BSC Unreachable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.3 OMC-BSC Link Failure: First Link Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.4 OMC-BSC Link Failure: Second Link Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.5 External Communication Link Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.6 OMC-MFS SSH Tunnel Establishment Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.7 OMC-TC Link Failure: TC Unreachable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.8 OMC-TC Communication Failure: Unexpected Error in TC Response . . . . . . . . . . . . . . . . . . . 29
3 O&M Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.1 Hardware Audit Failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323.2 Alarm/State Audit Failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.3 DLS Backup Failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.4 BSC Autonomous DLS restoration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.5 Automatic Abis Programming Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383.6 Errors in checked DLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393.7 Errors in DLS checks scripts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4 SNMP Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414.1 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424.2 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.3 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464.4 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.5 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504.6 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.7 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.8 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534.9 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534.10 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544.11 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554.12 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564.13 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574.14 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 584.15 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 594.16 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604.17 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614.18 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624.19 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634.20 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644.21 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 654.22 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 664.23 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 674.24 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684.25 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694.26 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
3BK 21205 AAAA PCZZA Ed.05 3 / 182
Contents
4.27 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714.28 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724.29 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734.30 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 744.31 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 754.32 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 764.33 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 774.34 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.35 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 794.36 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804.37 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 814.38 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 824.39 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 834.40 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 844.41 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 854.42 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 864.43 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 874.44 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 884.45 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 894.46 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904.47 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914.48 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 924.49 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 934.50 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 944.51 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 954.52 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 964.53 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 974.54 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 984.55 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 994.56 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1004.57 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1014.58 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1024.59 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1034.60 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1044.61 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1054.62 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1064.63 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1074.64 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1084.65 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1094.66 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1104.67 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1114.68 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1124.69 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1134.70 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1144.71 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1154.72 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1164.73 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1174.74 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1184.75 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1194.76 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1204.77 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1214.78 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1224.79 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1234.80 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1244.81 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1254.82 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1264.83 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
4 / 182 3BK 21205 AAAA PCZZA Ed.05
Contents
4.84 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1284.85 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1294.86 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1304.87 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1314.88 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1324.89 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1334.90 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1344.91 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1354.92 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1364.93 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1374.94 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1384.95 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1394.96 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1404.97 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1414.98 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1424.99 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1434.100 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1444.101 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1454.102 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1464.103 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1474.104 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1484.105 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1494.106 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1504.107 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1514.108 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1524.109 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1534.110 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1544.111 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1554.112 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1564.113 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1574.114 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1584.115 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1594.116 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1604.117 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1614.118 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1624.119 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1634.120 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1644.121 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1654.122 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1664.123 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1674.124 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1684.125 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1694.126 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1704.127 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1714.128 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1724.129 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1734.130 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
5 OMC-R Alarms in AS Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1755.1 CPU Usage Over Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765.2 Memory Usage Over Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765.3 CPU Temperature Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765.4 FAN Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775.5 Partition / Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775.6 Partition /usr Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775.7 Partition /var Usage Ubove Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1785.8 Partition /alcatel Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1785.9 Partition /alcatel/base Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
3BK 21205 AAAA PCZZA Ed.05 5 / 182
Contents
5.10 Partition /backu Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1795.11 Partition /alcatel/oracle Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1795.12 StorEdge Has a Bad Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1795.13 Hard Disk Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805.14 Kernel Messages (EMERG) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805.15 Kernel Messages (ALERT) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805.16 Kernel Messages (CRIT) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1815.17 System Daemons Messages (EMERG) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1815.18 System Daemons Messages (ALERT) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1815.19 System Daemons Messages (CRIT) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
6 / 182 3BK 21205 AAAA PCZZA Ed.05
Figures
FiguresFigure 1: Internal Link Failure: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 2: OMC-BSC Link Failure: BSC Unreachable Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Figure 3: OMC-BSC Link Failure: First Link Down Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Figure 4: OMC-BSC Link Failure: Second Link Down Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Figure 5: External Communication Link Failure: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Figure 6: Hardware Audit Failed: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Figure 7: Alarm/State Audit Failed: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Figure 8: DLS Backup Failed: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Figure 9: BSC Autonomous DLS restoration: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Figure 10: Errors in checked DLS: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Figure 11: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Figure 12: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Figure 13: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Figure 14: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Figure 15: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3BK 21205 AAAA PCZZA Ed.05 7 / 182
Figures
8 / 182 3BK 21205 AAAA PCZZA Ed.05
Preface
PrefacePurpose The purpose of this document is to provide the operator with a structured
method for handling 9153 OMC-R alarm messages.This document contains a list of all 9153 OMC-R alarms, and the actionsrequired to remove them.It is not intended to describe all alarms generated by other subsystem such asBTS, MFS, BSC etc. components.
Whats New In Edition 05The following alarms have been added:
OMC-TC Link Failure: TC Unreachable (Section 2.7)OMC-TC Communication Failure: Unexpected Error in TC Response(Section 2.8).
Description improvement for alarms:
Errors in checked DLS (Section 3.6)Errors in DLS checks scripts (Section 3.7).
Severity was updated for alarm Internal Link Failure (Section 2.1).
In Edition 04Corrective action was updated for alarm OMC-BSC Link Failure: BSCUnreachable (Section 2.2).
In Edition 03Update with the new equipment naming.Alarm Errors in DLS checks scripts (Section 3.7) was added.
In Edition 02Update of reference for alarm Errors in checked DLS (Section 3.6).
In Edition 01Creation of OMC-MFS SSH Tunnel Establishment Failure (Section 2.6) andOMC-R Alarms in AS Class (Section 5).Creation of the Errors in checked DLS (Section 3.6) related to the DLScheck in BSC.
3BK 21205 AAAA PCZZA Ed.05 9 / 182
Preface
Audience This document is aimed at telecommunications operators responsible forperforming O&M fault handling and troubleshooting tasks.
Assumed Knowledge The operator must be familiar with the following:
Alcatel-Lucent O&M concept
Use of OMC-R terminals.
10 / 182 3BK 21205 AAAA PCZZA Ed.05
1 Introduction
1 Introduction
This section describes the structure of alarm messages.
3BK 21205 AAAA PCZZA Ed.05 11 / 182
1 Introduction
1.1 OverviewThis alarm dictionary provides additional information that is not displayed in thealarm messages sent to the terminals.The dictionary contains alarm definitions for each alarm type produced by the9153 OMC-R:
Communication alarms
O&M alarms.
1.2 Alarm DefinitionEach alarm definition describes the:
Alarm type
Alarm description
Impact on System
Corrective actions.
1.2.1 Alarm TypeThe Alarm Type identifies the type of problem the alarm refers to.This information is sub-divided into:
eventTypeidentifies the basic type of the alarm. Table 1 gives the possible valuesfor eventType.
probableCause
perceivedSeveritygives the severity level of the alarm. Table 2 gives the possible values forperceivedSeverity.
evenType Indicates....
Communications A problem with a procedure or process used to convey information from onepoint to another in the network.
Processing Error A software or processing fault.
Table 1: Event Types
12 / 182 3BK 21205 AAAA PCZZA Ed.05
1 Introduction
Severity Level Indicates...
Critical A serious fault condition which requires immediate corrections. Example: amanaged object goes out of service.
Major A fault condition which requires urgent correction action. Example: severedegradation in the operation of a managed object.
Minor A fault condition which does not affect service but corrective action should betaken to avoid a more serious fault.
Warning Detection of a potential fault condition. Action should be taken to diagnose andcorrect the problem to avoid a more serious fault condition.
Indeterminate The severity level cannot be defined by the resource which raised the alarm.
Table 2: Alarm Severity Levels
All alarms always give the date and time of the alarm. An alarm may alsocontain optional information, such as the notification id.
1.2.2 Alarm DescriptionIt gives a short description of the problem indicated by this alarm.
1.2.3 Impact on SystemIt gives a short description of the impact on the system due to the problemindicated by this alarm.
1.2.4 Corrective ActionTo solve the current alarm a graphical workflow chart is used. It shows therequired procedures by checks, tests and actions to determine the fault andfinally to solve the alarm.By clicking on a dedicated action field, a link to the detailed description of thetask will be opened when available.
3BK 21205 AAAA PCZZA Ed.05 13 / 182
1 Introduction
14 / 182 3BK 21205 AAAA PCZZA Ed.05
2 Communications Alarms
2 Communications Alarms
This section describes the meaning and corrective actions for each alarmraised on the communication with the supervised equipment (BTS, BSC, MFS).
3BK 21205 AAAA PCZZA Ed.05 15 / 182
2 Communications Alarms
2.1 Internal Link Failure
eventType Communications
probableCause CommunicationSubsystemFailure
Alarm Number 500000
perceivedSeverity Critical
Alarm Description Due to a failure in OMC-R internal processes, the OMC-R is not able tocommunicate with a BSC equipment.
Impact on System The BSC and all BTS related equipment is no more supervised.
The following flowchart describes the associated corrective actions for thisalarm.
Internal Link Failure
Processesmarked
red?
Restartstopped
process(es)
OMCR
Yes
Recheckprocess(es).Wait 30 min
to start RNUSM if RNIM was
stopped
OMCR
Do restartedProcess(es)stop again?
Alarmsolved
ContactSystem Support
No
No
CheckOMC
process(es)
OMCR
ContactSystem Support
Yes
Figure 1: Internal Link Failure: Corrective Actions
16 / 182 3BK 21205 AAAA PCZZA Ed.05
2 Communications Alarms
2.2 OMC-BSC Link Failure: BSC Unreachable
eventType Communications
probableCause CommunicationSubsystemFailure
Alarm Number 500001
perceivedSeverity Critical
Alarm Description Due to a wrong configuration or OMC hardware failure or network erroror BSC response time-out, the OMC is not able to communicate withthe BSC equipment. The alarm is raised when the BSC cannot bereached: both links are not usable (in case of BSC redundancy) or linknot usable (if no BSC redundancy).
Impact on System The BSC and all BTS related equipment are no more supervised.
3BK 21205 AAAA PCZZA Ed.05 17 / 182
2 Communications Alarms
The following flowchart describes the associated corrective actions for thisalarm in case of 9120 BSC.
OMCBSC Link Failure: BSC Unreachable
X.25 configuration correct?
Check X.25 configuration with X.25 tool
OMCR
Yes
X.25 linkin service?
Alarmsolved
ContactSystem Support
No
Yes
RecheckX.25 link
OMCR
No
X.25 network ok?
No Fix X.25 network problems
Yes
OMCR X.25 boards ok?
No
Yes
Check OMCR X.25 boards
Correct X.25 configuration if
required
OMCR
Onsite
BSC equipment ok?
Fix BSC equipmentproblems
No
Yes
Figure 2: OMC-BSC Link Failure: BSC Unreachable Corrective Actions
18 / 182 3BK 21205 AAAA PCZZA Ed.05
2 Communications Alarms
The following flowchart describes the associated corrective actions for thisalarm in case of 9130 BSC Evolution.
OMCBSC Link Failure: BSC Unreachable
IP configuration correct?
Check IP configuration
OMCR
Yes
Linkin service?
Alarmsolved
ContactSystem Support
No
Yes
Recheck link
OMCR
No
IP network ok?
No Fix IP network problems
Yes
OMCR Ethernet boards ok?
No
Yes
Check OMCR Ethernet boards
Correct IP configuration if
required
OMCR
Onsite
BSC equipment ok?
Fix BSC equipmentproblems
No
Yes
IP or MLPPP?
BSC MLPPP configuration
correct?
IP MLPPP
Correct BSC MLPPP
configuration
Extraction router MLPPP configuration
correct?
Correct router MLPPP
configuration
OMCR IP configuration
correct?
Check OMCR Ethernet boards
Router IP configuration
correct?Correct router
IP configuration
No
No
No
No
Yes
Yes
Yes
ContactSystem Support
No
Yes
OMCR
OMCR
Onsite
Onsite
3BK 21205 AAAA PCZZA Ed.05 19 / 182
2 Communications Alarms
2.3 OMC-BSC Link Failure: First Link Down
eventType Communications
probableCause CommunicationSubsystemFailure
Alarm Number 500002
perceivedSeverity Minor
Alarm Description Due to a wrong configuration or OMC hardware failure or networkerror or BSC response time-out, the OMC is not able to communicatewith the BSC equipment through the first of the two X25 links in caseof BSC redundancy. The BSC and all related BTS equipments aresupervised. The alarm is raised in order to warn the operator that thefirst link is down and must be repaired.
Impact on System First link is down between OMC and BSC in case of BSC redundancy.If there is no X.25 redundancy, the BSC and all BTS related equipmentis no more supervised.With X.25 redundancy there is no impact.
20 / 182 3BK 21205 AAAA PCZZA Ed.05
2 Communications Alarms
The following flowchart describes the associated corrective actions for thisalarm.
OMCBSC Link Failure: First Link
Down
X.25 configuration correct?
Check X.25 configuration with X.25 tool
OMCR
Yes
X.25 linkin service?
Alarmsolved
ContactSystem Support
No
Yes
RecheckX.25 link
OMCR
No
X.25 network ok?
No Fix X.25 network problems
Yes
OMCR X.25 boards ok?
No
Yes
Check OMCR X.25 boards
Correct X.25 configuration if
required
OMCR
Onsite
BSC equipment ok?
Fix BSC equipmentproblems
No
Yes
Figure 3: OMC-BSC Link Failure: First Link Down Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 21 / 182
2 Communications Alarms
2.4 OMC-BSC Link Failure: Second Link Down
eventType Communications
probableCause CommunicationSubsystemFailure
Alarm Number 500003
perceivedSeverity Minor
Alarm Description Due to a wrong configuration or OMC hardware failure or network erroror BSC response time-out, the OMC is not able to communicate withthe BSC equipment through the second of the two X25 links in caseof BSC redundancy. The BSC and all related BTS equipments aresupervised. The alarm is raised in order to warn the operator that thesecond link is down and must be repaired.
Impact on System Second link is down between OMC and BSC in case of BSCredundancy.If there is no X.25 redundancy, the BSC and all BTS related equipmentis no more supervised.With X.25 redundancy there is no impact.
22 / 182 3BK 21205 AAAA PCZZA Ed.05
2 Communications Alarms
The following flowchart describes the associated corrective actions for thisalarm.
OMCBSC Link Failure: Second Link
Down
X.25 configuration correct?
Check X.25 configuration with X.25 tool
OMCR
Yes
X.25 linkin service?
Alarmsolved
ContactSystem Support
No
Yes
RecheckX.25 link
OMCR
No
X.25 network ok?
No Fix X.25 network problems
Yes
OMCR X.25 boards ok?
No
Yes
Check OMCR X.25 boards
Correct X.25 configuration if
required
OMCR
Onsite
BSC equipment ok?
Fix BSC equipmentproblems
No
Yes
Figure 4: OMC-BSC Link Failure: Second Link Down Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 23 / 182
2 Communications Alarms
2.5 External Communication Link Failure
eventType Communications
probableCause CommunicationSubsystemFailure
Alarm Number 5000001
perceivedSeverity Critical
Alarm Description Due to:
a wrong configuration or
an OMC-R hardware failure or
a network error or
an MFS response timeout.The OMC-R is not able to communicate with the MFS equipment.
Impact on System The MFS related equipment is no more supervised.
24 / 182 3BK 21205 AAAA PCZZA Ed.05
2 Communications Alarms
The following flowchart describes the associated corrective actions for thisalarm.
Ext. Comm. Link Failure
X.25 OMC link
address at MFS correct?
CorrectX.25 OMC
link address
OMCR
Trigger HSI boards
replacement by OMCR service
OMCR
X.25 linkin service?
Alarmsolved
ContactSystem Support
HSI boardsin service?
no
IP networkof MFS router
in service?
no
yes
Trigger network/ router
repair action
OMCR
yes
X.25 network between
OMC and MFSin service?
no
OMCR
no
Alarms onMFS
equipment?
no
Solve MFS alarm(s)
OMCR
yes
RecheckX.25link
yes
yes
Trigger repairaction from
network provider
no
ContactSystem Supportno
Figure 5: External Communication Link Failure: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 25 / 182
2 Communications Alarms
2.6 OMC-MFS SSH Tunnel Establishment Failure
eventType Communications
probableCause CommunicationSubsystemFailure
Alarm Number 5000002
perceivedSeverity Critical
Alarm Description Due to a wrong configuration or network error, the OMC-MFS SSHtunnel cannot be established.
Impact on System The communication with MFS equipment is degraded. MFS equipmentcannot be configured.
The following flowchart describes the associated corrective actions for thisalarm.
OMCMFS SSH Tunnel Establishment Failure
Alarm cleared Alarmsolved
ContactSystem Support
Yes
Check if OMCs public keys are
correctly uploaded on MFS
No
26 / 182 3BK 21205 AAAA PCZZA Ed.05
2 Communications Alarms
2.7 OMC-TC Link Failure: TC Unreachable
eventType Communications
probableCause CommunicationSubsystemFailure
Alarm Number 500004
perceivedSeverity Critical
Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or TC response time-out, the OMC-R is not able to communicatewith the TC equipment. The alarm is raised when the TC cannot bereached: link not usable.
Impact on System The TC is no more supervised.
3BK 21205 AAAA PCZZA Ed.05 27 / 182
2 Communications Alarms
The following flowchart describes the associated corrective actions for thisalarm.
OMCTC Link Failure: TC Unreachable
IP configuration correct?
Check IP configuration
OMCR
Yes
Linkin service?
Alarmsolved
ContactSystem Support
No
Yes
Recheck link
OMCR
No
IP network ok?
No Fix IP network problems
Yes
OMCR Ethernet boards ok?
No
Yes
Check OMCR Ethernet boards
Correct IP configuration if
required
OMCR
Onsite
TC equipment ok?
Fix BSC equipmentproblems
No
Yes
28 / 182 3BK 21205 AAAA PCZZA Ed.05
2 Communications Alarms
2.8 OMC-TC Communication Failure: Unexpected Error in TCResponse
eventType Communications
probableCause CommunicationSubsystemFailure
Alarm Number 300001
perceivedSeverity Indeterminate
Alarm Description Due to an application failure, the OMC-R communication with TC willnot work properly. The alarm event is raised when the TC responseinclude an unexpected error related to an application failure on TC side.
Impact on System The OMC-R communication with TC is degraded.
Operator Action Check the software applications on TC side.
The following flowchart describes the associated corrective actions for thisalarm.
OMCTC Communication Failure: Unexpected Error in
TC Response
Alarm cleared Alarmsolved
ContactSystem Support
Yes
Check the software applications on TC
side
No
3BK 21205 AAAA PCZZA Ed.05 29 / 182
2 Communications Alarms
30 / 182 3BK 21205 AAAA PCZZA Ed.05
3 O&M Alarms
3 O&M Alarms
This section describes the meaning and corrective actions for each alarmraised on the O&M with the supervised equipment (BTS, BSC, MFS).
3BK 21205 AAAA PCZZA Ed.05 31 / 182
3 O&M Alarms
3.1 Hardware Audit Failed
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 500010
perceivedSeverity Major
Alarm Description Due to a failure during hardware audit, the hardware configurationis not correctly uploaded.
Impact on System The hardware audit of equipment fails. The configuration of the OMC-Rand the faulty equipment are not aligned.
32 / 182 3BK 21205 AAAA PCZZA Ed.05
3 O&M Alarms
The following flowchart describes the associated corrective actions for thisalarm.
Hardware Audit Failed
BTS:SBL OMLenabled/
unlocked?
Analyze/solveOML problem
OMCR
Alarmsolved
ContactSystem Support
no
Trigger newHardware
audit
yes
OMCR
AuditOK?
Triggerrepairaction
OMCR
RelatingBSC/BTSalarms?
Trigger newHardware
audit
OMCR
AuditOK?
StartOCPRtakeover
OMCR
no
AuditOK?
Trigger newHardware
audit
OMCR
yes
no
no
no
yes
yes
Alarmsolved
yes
Alarmsolved
Figure 6: Hardware Audit Failed: Corrective Actions
To isolate the fault: Check the transmission settings in BTS. Check thesector/TRE configuration versus equipped hardware (e.g. 2+2+2 TREsconfigured, but 4+4+4 TREs equipped in cabinet).
3BK 21205 AAAA PCZZA Ed.05 33 / 182
3 O&M Alarms
3.2 Alarm/State Audit Failed
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 500011
perceivedSeverity Major
Alarm Description Due to a failure during alarm/state audit, the equipment states andalarms are not correctly uploaded.
Impact on System The alarm and state audit of equipment fails. The OMC-R and thefaulty equipment are not aligned.
34 / 182 3BK 21205 AAAA PCZZA Ed.05
3 O&M Alarms
The following flowchart describes the associated corrective actions for thisalarm.
Alarm/State Audit Failed
BTS:SBL OMLenabled/
unlocked?
Analyze/solveOML problem
OMCR
Alarmsolved
ContactSystem Support
no
Trigger newalarm/state
audit
yes
OMCR
AuditOK?
Triggerrepairaction
OMCR
RelatingBSC/BTSalarms?
Trigger newalarm/state
audit
OMCR
AuditOK?
StartOCPRtakeover
OMCR
no
AuditOK?
Trigger newalarm/state
audit
OMCR
yes
yes
no
no
no
yes
yes Alarmsolved
Alarmsolved
Figure 7: Alarm/State Audit Failed: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 35 / 182
3 O&M Alarms
3.3 DLS Backup Failed
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 500012
perceivedSeverity Major
Alarm Description The running DLS backup can not be performed.
Impact on System The DLS backup fails. The running DLS is not stored in the OMC-Rdatabase.
The following flowchart describes the associated corrective actions for thisalarm.
DLS Backup Failed
Manual backup is ok?
OMCR
Alarmsolved
yes
Perform a manual backup
OMCR
Restart SCPR
OMCR
no
Perform a manual backup
Manual backup is ok?
Alarmsolved
yes
ContactSystem Support
no
Figure 8: DLS Backup Failed: Corrective Actions
36 / 182 3BK 21205 AAAA PCZZA Ed.05
3 O&M Alarms
3.4 BSC Autonomous DLS restoration
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 500013
perceivedSeverity Critical
Alarm Description Following repetitive BSC process crash, the BSC has autonomouslyrestored a backup DLS considering DLS corruption may be the causeof the crashes.
Impact on System The BSC autonomously restarts on the new DLS. Telecom & O&Moutage linked to the stop/create of the BSC Application processes.
The following flowchart describes the associated corrective actions for thisalarm.
DLS Backup Failed
OMCR
Perform a BSSHardware
Audit
Alarm cleared? Alarmsolved
yes
ContactSystem Support
no
Analize the possible
regressions terms of configuration
Perform a Radio Force
Configuration for the BSS
Figure 9: BSC Autonomous DLS restoration: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 37 / 182
3 O&M Alarms
3.5 Automatic Abis Programming Disabled
eventType Equipment
probableCause OperatorConfigurationOrCustomization
Alarm Number 500014
perceivedSeverity Major
Alarm Description The Programming Mode on Abis is set to "Manual". This parameter iscontrolled from Abis View.
Impact on System In case of "Manual" Programming Mode on Abis, all Abis modificationcommands passed by the operator are transferred to BSC, checked byBSC but stored only in BSC as future, not programmed configuration.Only when the operator triggers the Abis Programming, themodifications will be brought in force.Note that, during the "Manual" mode of Abis Programming any creationor change performed on Abis elements is immediately consideredas effective on the OMC-R although not yet taken into account in theoperational configuration and thus different from the effective Abistransmission.Differences are visible in TCU - RSL mapping shown in BSSUSMMain View and in TRX - RSL mapping shown in USOD. OMC-R data(corresponding to the future configuration) can be overwritten byeffective Abis transmission data through requesting HSDS Synthesis,TCU Load Report or BSC/BSS audits.On resuming the "Automatic" mode of Abis Programming anyinconsistency is cleared due to the included BSC Hardware Audit andBSC Alarm/State Audit that follow the transmission programming.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Full advantage of manual Abis Programming is taken by groupingcommands relative to the same TSU.Avoid modifications that lead to changing the TCU mode between FRand DR. It will lead to the TCU reset and to traffic outage. If suchmodification is necessary, please trigger the Abis Programming eitherby resuming the "Automatic" mode or by forcing the Abis Programming.Always resume the "Automatic" mode of Abis Programming after thelast Abis operation. Only then, the current alarm is cleared.
38 / 182 3BK 21205 AAAA PCZZA Ed.05
3 O&M Alarms
3.6 Errors in checked DLS
eventType ProcessingError
probableCause corruptData
Alarm Number 500015
perceivedSeverity Warning
Alarm Description The checked DLS contains error(s).
Impact on System After the running DLS is backuped, several checks are performed andsome of them fail.
The following flowchart describes the associated corrective actions for thisalarm.
Errors in checked DLS
Alarm cleared? Alarmsolved
yes
ContactSystem Support
no
Analyse the DLS check report via Log
Viewer
Fix the errors found in DLS
Figure 10: Errors in checked DLS: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 39 / 182
3 O&M Alarms
3.7 Errors in DLS checks scripts
eventType ProcessingError
probableCause corruptData
Alarm Number 500016
perceivedSeverity Warning
Alarm Description The DPCK unitary check scripts contain error(s).
Impact on System After the running DLS is backuped, several checks are performed andsome of them fail.
Operator Action Contact your local TAC.
40 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4 SNMP Class
This section describes the meaning and corrective actions for each SNMPalarm.
3BK 21205 AAAA PCZZA Ed.05 41 / 182
4 SNMP Class
4.1 Loss of Contact with SU
eventType Communications
probableCause CommunicationsSubsystemFailure
Alarm Number 6000099
perceivedSeverity Critical
Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.
42 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
The following flowchart describes the associated corrective actions for thisalarm.
Loss of Contact with SU
SU configuration correct?
Correct SU configuration
OMCR
Yes
Alarmsolved
ContactSystem Support
No Yes
No
IP network ok?
No Fix IP network problems
Yes
OMCR boards ok? No
Yes
Check OMCR boards
OMCR
Onsite
External router ok?
Fix external router
problems
No
Yes
SU device ok? Fix SU device problems
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
No
No
No
No
Yes
Yes
Yes
Yes
Figure 11: Loss of Contact with SU: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 43 / 182
4 SNMP Class
4.2 Loss of Contact with SU
eventType Communications
probableCause CommunicationsSubsystemFailure
Alarm Number 6000149
perceivedSeverity Critical
Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.
44 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
The following flowchart describes the associated corrective actions for thisalarm.
Loss of Contact with SU
SU configuration correct?
Correct SU configuration
OMCR
Yes
Alarmsolved
ContactSystem Support
No Yes
No
IP network ok?
No Fix IP network problems
Yes
OMCR boards ok? No
Yes
Check OMCR boards
OMCR
Onsite
External router ok?
Fix external router
problems
No
Yes
SU device ok? Fix SU device problems
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
No
No
No
No
Yes
Yes
Yes
Yes
Figure 12: Loss of Contact with SU: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 45 / 182
4 SNMP Class
4.3 Loss of Contact with SU
eventType Communications
probableCause CommunicationsSubsystemFailure
Alarm Number 6000199
perceivedSeverity Critical
Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.
46 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
The following flowchart describes the associated corrective actions for thisalarm.
Loss of Contact with SU
SU configuration correct?
Correct SU configuration
OMCR
Yes
Alarmsolved
ContactSystem Support
No Yes
No
IP network ok?
No Fix IP network problems
Yes
OMCR boards ok? No
Yes
Check OMCR boards
OMCR
Onsite
External router ok?
Fix external router
problems
No
Yes
SU device ok? Fix SU device problems
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
No
No
No
No
Yes
Yes
Yes
Yes
Figure 13: Loss of Contact with SU: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 47 / 182
4 SNMP Class
4.4 Loss of Contact with SU
eventType Communications
probableCause CommunicationsSubsystemFailure
Alarm Number 6000249
perceivedSeverity Critical
Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.
48 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
The following flowchart describes the associated corrective actions for thisalarm.
Loss of Contact with SU
SU configuration correct?
Correct SU configuration
OMCR
Yes
Alarmsolved
ContactSystem Support
No Yes
No
IP network ok?
No Fix IP network problems
Yes
OMCR boards ok? No
Yes
Check OMCR boards
OMCR
Onsite
External router ok?
Fix external router
problems
No
Yes
SU device ok? Fix SU device problems
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
No
No
No
No
Yes
Yes
Yes
Yes
Figure 14: Loss of Contact with SU: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 49 / 182
4 SNMP Class
4.5 Loss of Contact with SU
eventType Communications
probableCause CommunicationsSubsystemFailure
Alarm Number 6000299
perceivedSeverity Critical
Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.
50 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
The following flowchart describes the associated corrective actions for thisalarm.
Loss of Contact with SU
SU configuration correct?
Correct SU configuration
OMCR
Yes
Alarmsolved
ContactSystem Support
No Yes
No
IP network ok?
No Fix IP network problems
Yes
OMCR boards ok? No
Yes
Check OMCR boards
OMCR
Onsite
External router ok?
Fix external router
problems
No
Yes
SU device ok? Fix SU device problems
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
Alarm cleared?
No
No
No
No
Yes
Yes
Yes
Yes
Figure 15: Loss of Contact with SU: Corrective Actions
3BK 21205 AAAA PCZZA Ed.05 51 / 182
4 SNMP Class
4.6 SNMP Manager Trapd Daemon Down
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 6000100
perceivedSeverity Critical
Alarm Description SNMP Manager Trapd daemon failed.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.The following table describes the associated corrective actions for this alarm.
Corrective Actions Re-launch the SNMP Manager Trapd daemon.
4.7 SNMP Manager Trapd Daemon Down
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 6000150
perceivedSeverity Critical
Alarm Description SNMP Manager Trapd daemon failed.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.
Corrective Actions Re-launch the SNMP Manager Trapd daemon.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Re-launch the SNMP Manager Trapd daemon.
52 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.8 SNMP Manager Trapd Daemon Down
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 6000200
perceivedSeverity Critical
Alarm Description SNMP Manager Trapd daemon failed.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.
Corrective Actions Re-launch the SNMP Manager Trapd daemon.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Re-launch the SNMP Manager Trapd daemon.
4.9 SNMP Manager Trapd Daemon Down
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 6000250
perceivedSeverity Critical
Alarm Description SNMP Manager Trapd daemon failed.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.The following table describes the associated corrective actions for this alarm.
Corrective Actions Re-launch the SNMP Manager Trapd daemon.
3BK 21205 AAAA PCZZA Ed.05 53 / 182
4 SNMP Class
4.10 SNMP Manager Trapd Daemon Down
eventType ProcessingError
probableCause SoftwareProgramAbnormallyTerminate
Alarm Number 6000300
perceivedSeverity Critical
Alarm Description SNMP Manager Trapd daemon failed.
Impact on System The SU device is no more supervised.
Note: The PerceivedSeverity and additional text are customizable.The following table describes the associated corrective actions for this alarm.
Corrective Actions Re-launch the SNMP Manager Trapd daemon.
54 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.11 External Alarm No 1
eventType Environmental
probableCause Indeterminate
Alarm Number 6000051
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 55 / 182
4 SNMP Class
4.12 External Alarm No 2
eventType Environmental
probableCause Indeterminate
Alarm Number 6000052
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
56 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.13 External Alarm No 3
eventType Environmental
probableCause Indeterminate
Alarm Number 6000053
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 57 / 182
4 SNMP Class
4.14 External Alarm No 4
eventType Environmental
probableCause Indeterminate
Alarm Number 6000054
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
58 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.15 External Alarm No 5
eventType Environmental
probableCause Indeterminate
Alarm Number 6000055
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 59 / 182
4 SNMP Class
4.16 External Alarm No 6
eventType Environmental
probableCause Indeterminate
Alarm Number 6000056
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
60 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.17 External Alarm No 7
eventType Environmental
probableCause Indeterminate
Alarm Number 6000057
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 61 / 182
4 SNMP Class
4.18 External Alarm No 8
eventType Environmental
probableCause Indeterminate
Alarm Number 6000058
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
62 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.19 External Alarm No 9
eventType Environmental
probableCause Indeterminate
Alarm Number 6000059
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 63 / 182
4 SNMP Class
4.20 External Alarm No 10
eventType Environmental
probableCause Indeterminate
Alarm Number 6000060
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
64 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.21 External Alarm No 11
eventType Environmental
probableCause Indeterminate
Alarm Number 6000061
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 65 / 182
4 SNMP Class
4.22 External Alarm No 12
eventType Environmental
probableCause Indeterminate
Alarm Number 6000062
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
66 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.23 External Alarm No 13
eventType Environmental
probableCause Indeterminate
Alarm Number 6000063
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 67 / 182
4 SNMP Class
4.24 External Alarm No 14
eventType Environmental
probableCause Indeterminate
Alarm Number 6000064
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
68 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.25 External Alarm No 15
eventType Environmental
probableCause Indeterminate
Alarm Number 6000065
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 69 / 182
4 SNMP Class
4.26 External Alarm No 16
eventType Environmental
probableCause Indeterminate
Alarm Number 6000066
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
70 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.27 External Alarm No 17
eventType Environmental
probableCause Indeterminate
Alarm Number 6000067
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 71 / 182
4 SNMP Class
4.28 External Alarm No 18
eventType Environmental
probableCause Indeterminate
Alarm Number 6000068
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
72 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.29 External Alarm No 19
eventType Environmental
probableCause Indeterminate
Alarm Number 6000069
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 73 / 182
4 SNMP Class
4.30 External Alarm No 20
eventType Environmental
probableCause Indeterminate
Alarm Number 6000070
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
74 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.31 External Alarm No 21
eventType Environmental
probableCause Indeterminate
Alarm Number 6000071
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 75 / 182
4 SNMP Class
4.32 External Alarm No 22
eventType Environmental
probableCause Indeterminate
Alarm Number 6000072
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
76 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.33 External Alarm No 23
eventType Environmental
probableCause Indeterminate
Alarm Number 6000073
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 77 / 182
4 SNMP Class
4.34 External Alarm No 24
eventType Environmental
probableCause Indeterminate
Alarm Number 6000074
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
78 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.35 External Alarm No 1
eventType Environmental
probableCause Indeterminate
Alarm Number 6000101
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 79 / 182
4 SNMP Class
4.36 External Alarm No 2
eventType Environmental
probableCause Indeterminate
Alarm Number 6000102
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
80 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.37 External Alarm No 3
eventType Environmental
probableCause Indeterminate
Alarm Number 6000103
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 81 / 182
4 SNMP Class
4.38 External Alarm No 4
eventType Environmental
probableCause Indeterminate
Alarm Number 6000104
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
82 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.39 External Alarm No 5
eventType Environmental
probableCause Indeterminate
Alarm Number 6000105
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 83 / 182
4 SNMP Class
4.40 External Alarm No 6
eventType Environmental
probableCause Indeterminate
Alarm Number 6000106
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
84 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.41 External Alarm No 7
eventType Environmental
probableCause Indeterminate
Alarm Number 6000107
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 85 / 182
4 SNMP Class
4.42 External Alarm No 8
eventType Environmental
probableCause Indeterminate
Alarm Number 6000108
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
86 / 182 3BK 21205 AAAA PCZZA Ed.05
4 SNMP Class
4.43 External Alarm No 9
eventType Environmental
probableCause Indeterminate
Alarm Number 6000109
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm profile.
3BK 21205 AAAA PCZZA Ed.05 87 / 182
4 SNMP Class
4.44 External Alarm No 10
eventType Environmental
probableCause Indeterminate
Alarm Number 6000110
perceivedSeverity Warning
Alarm Description Depends on alarm profile.Customizable by customer.
Impact on System Depends on alarm profile.
Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:
Alarm Name
Additional Text
Alarm Severity
Probable Cause.
The following table describes the associated corrective actions for this alarm.
Corrective Actions Depends on alarm prof