  • Alcatel-Lucent GSM

    9153 OMC-R Alarm Dictionary

    OMC Document

    Reference Guide

    Release B10

    3BK 21205 AAAA PCZZA Ed.05

  • Status RELEASED

    Short title 9153 OMC-R Alarm Dictionary

    All rights reserved. Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel-Lucent.

    BLANK PAGE BREAK

    2 / 182 3BK 21205 AAAA PCZZA Ed.05

  • Contents

    ContentsPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2 Alarm Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    1.2.1 Alarm Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121.2.2 Alarm Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.2.3 Impact on System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131.2.4 Corrective Action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    2 Communications Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152.1 Internal Link Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.2 OMC-BSC Link Failure: BSC Unreachable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.3 OMC-BSC Link Failure: First Link Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.4 OMC-BSC Link Failure: Second Link Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222.5 External Communication Link Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.6 OMC-MFS SSH Tunnel Establishment Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.7 OMC-TC Link Failure: TC Unreachable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.8 OMC-TC Communication Failure: Unexpected Error in TC Response . . . . . . . . . . . . . . . . . . . 29

    3 O&M Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.1 Hardware Audit Failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323.2 Alarm/State Audit Failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.3 DLS Backup Failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.4 BSC Autonomous DLS restoration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.5 Automatic Abis Programming Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383.6 Errors in checked DLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393.7 Errors in DLS checks scripts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

    4 SNMP Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414.1 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424.2 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.3 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464.4 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.5 Loss of Contact with SU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504.6 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.7 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.8 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534.9 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534.10 SNMP Manager Trapd Daemon Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544.11 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554.12 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564.13 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574.14 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 584.15 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 594.16 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604.17 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614.18 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624.19 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634.20 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644.21 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 654.22 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 664.23 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 674.24 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684.25 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694.26 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

    3BK 21205 AAAA PCZZA Ed.05 3 / 182

  • Contents

    4.27 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714.28 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724.29 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734.30 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 744.31 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 754.32 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 764.33 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 774.34 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.35 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 794.36 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804.37 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 814.38 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 824.39 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 834.40 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 844.41 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 854.42 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 864.43 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 874.44 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 884.45 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 894.46 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 904.47 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914.48 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 924.49 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 934.50 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 944.51 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 954.52 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 964.53 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 974.54 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 984.55 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 994.56 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1004.57 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1014.58 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1024.59 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1034.60 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1044.61 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1054.62 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1064.63 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1074.64 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1084.65 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1094.66 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1104.67 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1114.68 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1124.69 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1134.70 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1144.71 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1154.72 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1164.73 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1174.74 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1184.75 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1194.76 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1204.77 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1214.78 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1224.79 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1234.80 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1244.81 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1254.82 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1264.83 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127

    4 / 182 3BK 21205 AAAA PCZZA Ed.05

  • Contents

    4.84 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1284.85 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1294.86 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1304.87 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1314.88 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1324.89 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1334.90 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1344.91 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1354.92 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1364.93 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1374.94 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1384.95 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1394.96 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1404.97 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1414.98 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1424.99 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1434.100 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1444.101 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1454.102 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1464.103 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1474.104 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1484.105 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1494.106 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1504.107 External Alarm No 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1514.108 External Alarm No 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1524.109 External Alarm No 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1534.110 External Alarm No 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1544.111 External Alarm No 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1554.112 External Alarm No 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1564.113 External Alarm No 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1574.114 External Alarm No 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1584.115 External Alarm No 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1594.116 External Alarm No 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1604.117 External Alarm No 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1614.118 External Alarm No 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1624.119 External Alarm No 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1634.120 External Alarm No 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1644.121 External Alarm No 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1654.122 External Alarm No 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1664.123 External Alarm No 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1674.124 External Alarm No 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1684.125 External Alarm No 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1694.126 External Alarm No 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1704.127 External Alarm No 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1714.128 External Alarm No 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1724.129 External Alarm No 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1734.130 External Alarm No 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174

    5 OMC-R Alarms in AS Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1755.1 CPU Usage Over Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765.2 Memory Usage Over Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765.3 CPU Temperature Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1765.4 FAN Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775.5 Partition / Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775.6 Partition /usr Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1775.7 Partition /var Usage Ubove Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1785.8 Partition /alcatel Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1785.9 Partition /alcatel/base Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178

    3BK 21205 AAAA PCZZA Ed.05 5 / 182

  • Contents

    5.10 Partition /backu Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1795.11 Partition /alcatel/oracle Usage Above Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1795.12 StorEdge Has a Bad Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1795.13 Hard Disk Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805.14 Kernel Messages (EMERG) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805.15 Kernel Messages (ALERT) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1805.16 Kernel Messages (CRIT) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1815.17 System Daemons Messages (EMERG) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1815.18 System Daemons Messages (ALERT) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1815.19 System Daemons Messages (CRIT) (/var/log/alarms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182

    6 / 182 3BK 21205 AAAA PCZZA Ed.05

  • Figures

    FiguresFigure 1: Internal Link Failure: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Figure 2: OMC-BSC Link Failure: BSC Unreachable Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Figure 3: OMC-BSC Link Failure: First Link Down Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Figure 4: OMC-BSC Link Failure: Second Link Down Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Figure 5: External Communication Link Failure: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Figure 6: Hardware Audit Failed: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Figure 7: Alarm/State Audit Failed: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Figure 8: DLS Backup Failed: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Figure 9: BSC Autonomous DLS restoration: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Figure 10: Errors in checked DLS: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Figure 11: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Figure 12: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Figure 13: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Figure 14: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Figure 15: Loss of Contact with SU: Corrective Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

    3BK 21205 AAAA PCZZA Ed.05 7 / 182

  • Figures

    8 / 182 3BK 21205 AAAA PCZZA Ed.05

  • Preface

    PrefacePurpose The purpose of this document is to provide the operator with a structured

    method for handling 9153 OMC-R alarm messages.This document contains a list of all 9153 OMC-R alarms, and the actionsrequired to remove them.It is not intended to describe all alarms generated by other subsystem such asBTS, MFS, BSC etc. components.

    Whats New In Edition 05The following alarms have been added:

    OMC-TC Link Failure: TC Unreachable (Section 2.7)OMC-TC Communication Failure: Unexpected Error in TC Response(Section 2.8).

    Description improvement for alarms:

    Errors in checked DLS (Section 3.6)Errors in DLS checks scripts (Section 3.7).

    Severity was updated for alarm Internal Link Failure (Section 2.1).

    In Edition 04Corrective action was updated for alarm OMC-BSC Link Failure: BSCUnreachable (Section 2.2).

    In Edition 03Update with the new equipment naming.Alarm Errors in DLS checks scripts (Section 3.7) was added.

    In Edition 02Update of reference for alarm Errors in checked DLS (Section 3.6).

    In Edition 01Creation of OMC-MFS SSH Tunnel Establishment Failure (Section 2.6) andOMC-R Alarms in AS Class (Section 5).Creation of the Errors in checked DLS (Section 3.6) related to the DLScheck in BSC.

    3BK 21205 AAAA PCZZA Ed.05 9 / 182

  • Preface

    Audience This document is aimed at telecommunications operators responsible forperforming O&M fault handling and troubleshooting tasks.

    Assumed Knowledge The operator must be familiar with the following:

    Alcatel-Lucent O&M concept

    Use of OMC-R terminals.

    10 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 1 Introduction

    1 Introduction

    This section describes the structure of alarm messages.

    3BK 21205 AAAA PCZZA Ed.05 11 / 182

  • 1 Introduction

    1.1 OverviewThis alarm dictionary provides additional information that is not displayed in thealarm messages sent to the terminals.The dictionary contains alarm definitions for each alarm type produced by the9153 OMC-R:

    Communication alarms

    O&M alarms.

    1.2 Alarm DefinitionEach alarm definition describes the:

    Alarm type

    Alarm description

    Impact on System

    Corrective actions.

    1.2.1 Alarm TypeThe Alarm Type identifies the type of problem the alarm refers to.This information is sub-divided into:

    eventTypeidentifies the basic type of the alarm. Table 1 gives the possible valuesfor eventType.

    probableCause

    perceivedSeveritygives the severity level of the alarm. Table 2 gives the possible values forperceivedSeverity.

    evenType Indicates....

    Communications A problem with a procedure or process used to convey information from onepoint to another in the network.

    Processing Error A software or processing fault.

    Table 1: Event Types

    12 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 1 Introduction

    Severity Level Indicates...

    Critical A serious fault condition which requires immediate corrections. Example: amanaged object goes out of service.

    Major A fault condition which requires urgent correction action. Example: severedegradation in the operation of a managed object.

    Minor A fault condition which does not affect service but corrective action should betaken to avoid a more serious fault.

    Warning Detection of a potential fault condition. Action should be taken to diagnose andcorrect the problem to avoid a more serious fault condition.

    Indeterminate The severity level cannot be defined by the resource which raised the alarm.

    Table 2: Alarm Severity Levels

    All alarms always give the date and time of the alarm. An alarm may alsocontain optional information, such as the notification id.

    1.2.2 Alarm DescriptionIt gives a short description of the problem indicated by this alarm.

    1.2.3 Impact on SystemIt gives a short description of the impact on the system due to the problemindicated by this alarm.

    1.2.4 Corrective ActionTo solve the current alarm a graphical workflow chart is used. It shows therequired procedures by checks, tests and actions to determine the fault andfinally to solve the alarm.By clicking on a dedicated action field, a link to the detailed description of thetask will be opened when available.

    3BK 21205 AAAA PCZZA Ed.05 13 / 182

  • 1 Introduction

    14 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 2 Communications Alarms

    2 Communications Alarms

    This section describes the meaning and corrective actions for each alarmraised on the communication with the supervised equipment (BTS, BSC, MFS).

    3BK 21205 AAAA PCZZA Ed.05 15 / 182

  • 2 Communications Alarms

    2.1 Internal Link Failure

    eventType Communications

    probableCause CommunicationSubsystemFailure

    Alarm Number 500000

    perceivedSeverity Critical

    Alarm Description Due to a failure in OMC-R internal processes, the OMC-R is not able tocommunicate with a BSC equipment.

    Impact on System The BSC and all BTS related equipment is no more supervised.

    The following flowchart describes the associated corrective actions for thisalarm.

    Internal Link Failure

    Processesmarked

    red?

    Restartstopped

    process(es)

    OMCR

    Yes

    Recheckprocess(es).Wait 30 min

    to start RNUSM if RNIM was

    stopped

    OMCR

    Do restartedProcess(es)stop again?

    Alarmsolved

    ContactSystem Support

    No

    No

    CheckOMC

    process(es)

    OMCR

    ContactSystem Support

    Yes

    Figure 1: Internal Link Failure: Corrective Actions

    16 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 2 Communications Alarms

    2.2 OMC-BSC Link Failure: BSC Unreachable

    eventType Communications

    probableCause CommunicationSubsystemFailure

    Alarm Number 500001

    perceivedSeverity Critical

    Alarm Description Due to a wrong configuration or OMC hardware failure or network erroror BSC response time-out, the OMC is not able to communicate withthe BSC equipment. The alarm is raised when the BSC cannot bereached: both links are not usable (in case of BSC redundancy) or linknot usable (if no BSC redundancy).

    Impact on System The BSC and all BTS related equipment are no more supervised.

    3BK 21205 AAAA PCZZA Ed.05 17 / 182

  • 2 Communications Alarms

    The following flowchart describes the associated corrective actions for thisalarm in case of 9120 BSC.

    OMCBSC Link Failure: BSC Unreachable

    X.25 configuration correct?

    Check X.25 configuration with X.25 tool

    OMCR

    Yes

    X.25 linkin service?

    Alarmsolved

    ContactSystem Support

    No

    Yes

    RecheckX.25 link

    OMCR

    No

    X.25 network ok?

    No Fix X.25 network problems

    Yes

    OMCR X.25 boards ok?

    No

    Yes

    Check OMCR X.25 boards

    Correct X.25 configuration if

    required

    OMCR

    Onsite

    BSC equipment ok?

    Fix BSC equipmentproblems

    No

    Yes

    Figure 2: OMC-BSC Link Failure: BSC Unreachable Corrective Actions

    18 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 2 Communications Alarms

    The following flowchart describes the associated corrective actions for thisalarm in case of 9130 BSC Evolution.

    OMCBSC Link Failure: BSC Unreachable

    IP configuration correct?

    Check IP configuration

    OMCR

    Yes

    Linkin service?

    Alarmsolved

    ContactSystem Support

    No

    Yes

    Recheck link

    OMCR

    No

    IP network ok?

    No Fix IP network problems

    Yes

    OMCR Ethernet boards ok?

    No

    Yes

    Check OMCR Ethernet boards

    Correct IP configuration if

    required

    OMCR

    Onsite

    BSC equipment ok?

    Fix BSC equipmentproblems

    No

    Yes

    IP or MLPPP?

    BSC MLPPP configuration

    correct?

    IP MLPPP

    Correct BSC MLPPP

    configuration

    Extraction router MLPPP configuration

    correct?

    Correct router MLPPP

    configuration

    OMCR IP configuration

    correct?

    Check OMCR Ethernet boards

    Router IP configuration

    correct?Correct router

    IP configuration

    No

    No

    No

    No

    Yes

    Yes

    Yes

    ContactSystem Support

    No

    Yes

    OMCR

    OMCR

    Onsite

    Onsite

    3BK 21205 AAAA PCZZA Ed.05 19 / 182

  • 2 Communications Alarms

    2.3 OMC-BSC Link Failure: First Link Down

    eventType Communications

    probableCause CommunicationSubsystemFailure

    Alarm Number 500002

    perceivedSeverity Minor

    Alarm Description Due to a wrong configuration or OMC hardware failure or networkerror or BSC response time-out, the OMC is not able to communicatewith the BSC equipment through the first of the two X25 links in caseof BSC redundancy. The BSC and all related BTS equipments aresupervised. The alarm is raised in order to warn the operator that thefirst link is down and must be repaired.

    Impact on System First link is down between OMC and BSC in case of BSC redundancy.If there is no X.25 redundancy, the BSC and all BTS related equipmentis no more supervised.With X.25 redundancy there is no impact.

    20 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 2 Communications Alarms

    The following flowchart describes the associated corrective actions for thisalarm.

    OMCBSC Link Failure: First Link

    Down

    X.25 configuration correct?

    Check X.25 configuration with X.25 tool

    OMCR

    Yes

    X.25 linkin service?

    Alarmsolved

    ContactSystem Support

    No

    Yes

    RecheckX.25 link

    OMCR

    No

    X.25 network ok?

    No Fix X.25 network problems

    Yes

    OMCR X.25 boards ok?

    No

    Yes

    Check OMCR X.25 boards

    Correct X.25 configuration if

    required

    OMCR

    Onsite

    BSC equipment ok?

    Fix BSC equipmentproblems

    No

    Yes

    Figure 3: OMC-BSC Link Failure: First Link Down Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 21 / 182

  • 2 Communications Alarms

    2.4 OMC-BSC Link Failure: Second Link Down

    eventType Communications

    probableCause CommunicationSubsystemFailure

    Alarm Number 500003

    perceivedSeverity Minor

    Alarm Description Due to a wrong configuration or OMC hardware failure or network erroror BSC response time-out, the OMC is not able to communicate withthe BSC equipment through the second of the two X25 links in caseof BSC redundancy. The BSC and all related BTS equipments aresupervised. The alarm is raised in order to warn the operator that thesecond link is down and must be repaired.

    Impact on System Second link is down between OMC and BSC in case of BSCredundancy.If there is no X.25 redundancy, the BSC and all BTS related equipmentis no more supervised.With X.25 redundancy there is no impact.

    22 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 2 Communications Alarms

    The following flowchart describes the associated corrective actions for thisalarm.

    OMCBSC Link Failure: Second Link

    Down

    X.25 configuration correct?

    Check X.25 configuration with X.25 tool

    OMCR

    Yes

    X.25 linkin service?

    Alarmsolved

    ContactSystem Support

    No

    Yes

    RecheckX.25 link

    OMCR

    No

    X.25 network ok?

    No Fix X.25 network problems

    Yes

    OMCR X.25 boards ok?

    No

    Yes

    Check OMCR X.25 boards

    Correct X.25 configuration if

    required

    OMCR

    Onsite

    BSC equipment ok?

    Fix BSC equipmentproblems

    No

    Yes

    Figure 4: OMC-BSC Link Failure: Second Link Down Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 23 / 182

  • 2 Communications Alarms

    2.5 External Communication Link Failure

    eventType Communications

    probableCause CommunicationSubsystemFailure

    Alarm Number 5000001

    perceivedSeverity Critical

    Alarm Description Due to:

    a wrong configuration or

    an OMC-R hardware failure or

    a network error or

    an MFS response timeout.The OMC-R is not able to communicate with the MFS equipment.

    Impact on System The MFS related equipment is no more supervised.

    24 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 2 Communications Alarms

    The following flowchart describes the associated corrective actions for thisalarm.

    Ext. Comm. Link Failure

    X.25 OMC link

    address at MFS correct?

    CorrectX.25 OMC

    link address

    OMCR

    Trigger HSI boards

    replacement by OMCR service

    OMCR

    X.25 linkin service?

    Alarmsolved

    ContactSystem Support

    HSI boardsin service?

    no

    IP networkof MFS router

    in service?

    no

    yes

    Trigger network/ router

    repair action

    OMCR

    yes

    X.25 network between

    OMC and MFSin service?

    no

    OMCR

    no

    Alarms onMFS

    equipment?

    no

    Solve MFS alarm(s)

    OMCR

    yes

    RecheckX.25link

    yes

    yes

    Trigger repairaction from

    network provider

    no

    ContactSystem Supportno

    Figure 5: External Communication Link Failure: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 25 / 182

  • 2 Communications Alarms

    2.6 OMC-MFS SSH Tunnel Establishment Failure

    eventType Communications

    probableCause CommunicationSubsystemFailure

    Alarm Number 5000002

    perceivedSeverity Critical

    Alarm Description Due to a wrong configuration or network error, the OMC-MFS SSHtunnel cannot be established.

    Impact on System The communication with MFS equipment is degraded. MFS equipmentcannot be configured.

    The following flowchart describes the associated corrective actions for thisalarm.

    OMCMFS SSH Tunnel Establishment Failure

    Alarm cleared Alarmsolved

    ContactSystem Support

    Yes

    Check if OMCs public keys are

    correctly uploaded on MFS

    No

    26 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 2 Communications Alarms

    2.7 OMC-TC Link Failure: TC Unreachable

    eventType Communications

    probableCause CommunicationSubsystemFailure

    Alarm Number 500004

    perceivedSeverity Critical

    Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or TC response time-out, the OMC-R is not able to communicatewith the TC equipment. The alarm is raised when the TC cannot bereached: link not usable.

    Impact on System The TC is no more supervised.

    3BK 21205 AAAA PCZZA Ed.05 27 / 182

  • 2 Communications Alarms

    The following flowchart describes the associated corrective actions for thisalarm.

    OMCTC Link Failure: TC Unreachable

    IP configuration correct?

    Check IP configuration

    OMCR

    Yes

    Linkin service?

    Alarmsolved

    ContactSystem Support

    No

    Yes

    Recheck link

    OMCR

    No

    IP network ok?

    No Fix IP network problems

    Yes

    OMCR Ethernet boards ok?

    No

    Yes

    Check OMCR Ethernet boards

    Correct IP configuration if

    required

    OMCR

    Onsite

    TC equipment ok?

    Fix BSC equipmentproblems

    No

    Yes

    28 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 2 Communications Alarms

    2.8 OMC-TC Communication Failure: Unexpected Error in TCResponse

    eventType Communications

    probableCause CommunicationSubsystemFailure

    Alarm Number 300001

    perceivedSeverity Indeterminate

    Alarm Description Due to an application failure, the OMC-R communication with TC willnot work properly. The alarm event is raised when the TC responseinclude an unexpected error related to an application failure on TC side.

    Impact on System The OMC-R communication with TC is degraded.

    Operator Action Check the software applications on TC side.

    The following flowchart describes the associated corrective actions for thisalarm.

    OMCTC Communication Failure: Unexpected Error in

    TC Response

    Alarm cleared Alarmsolved

    ContactSystem Support

    Yes

    Check the software applications on TC

    side

    No

    3BK 21205 AAAA PCZZA Ed.05 29 / 182

  • 2 Communications Alarms

    30 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 3 O&M Alarms

    3 O&M Alarms

    This section describes the meaning and corrective actions for each alarmraised on the O&M with the supervised equipment (BTS, BSC, MFS).

    3BK 21205 AAAA PCZZA Ed.05 31 / 182

  • 3 O&M Alarms

    3.1 Hardware Audit Failed

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 500010

    perceivedSeverity Major

    Alarm Description Due to a failure during hardware audit, the hardware configurationis not correctly uploaded.

    Impact on System The hardware audit of equipment fails. The configuration of the OMC-Rand the faulty equipment are not aligned.

    32 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 3 O&M Alarms

    The following flowchart describes the associated corrective actions for thisalarm.

    Hardware Audit Failed

    BTS:SBL OMLenabled/

    unlocked?

    Analyze/solveOML problem

    OMCR

    Alarmsolved

    ContactSystem Support

    no

    Trigger newHardware

    audit

    yes

    OMCR

    AuditOK?

    Triggerrepairaction

    OMCR

    RelatingBSC/BTSalarms?

    Trigger newHardware

    audit

    OMCR

    AuditOK?

    StartOCPRtakeover

    OMCR

    no

    AuditOK?

    Trigger newHardware

    audit

    OMCR

    yes

    no

    no

    no

    yes

    yes

    Alarmsolved

    yes

    Alarmsolved

    Figure 6: Hardware Audit Failed: Corrective Actions

    To isolate the fault: Check the transmission settings in BTS. Check thesector/TRE configuration versus equipped hardware (e.g. 2+2+2 TREsconfigured, but 4+4+4 TREs equipped in cabinet).

    3BK 21205 AAAA PCZZA Ed.05 33 / 182

  • 3 O&M Alarms

    3.2 Alarm/State Audit Failed

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 500011

    perceivedSeverity Major

    Alarm Description Due to a failure during alarm/state audit, the equipment states andalarms are not correctly uploaded.

    Impact on System The alarm and state audit of equipment fails. The OMC-R and thefaulty equipment are not aligned.

    34 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 3 O&M Alarms

    The following flowchart describes the associated corrective actions for thisalarm.

    Alarm/State Audit Failed

    BTS:SBL OMLenabled/

    unlocked?

    Analyze/solveOML problem

    OMCR

    Alarmsolved

    ContactSystem Support

    no

    Trigger newalarm/state

    audit

    yes

    OMCR

    AuditOK?

    Triggerrepairaction

    OMCR

    RelatingBSC/BTSalarms?

    Trigger newalarm/state

    audit

    OMCR

    AuditOK?

    StartOCPRtakeover

    OMCR

    no

    AuditOK?

    Trigger newalarm/state

    audit

    OMCR

    yes

    yes

    no

    no

    no

    yes

    yes Alarmsolved

    Alarmsolved

    Figure 7: Alarm/State Audit Failed: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 35 / 182

  • 3 O&M Alarms

    3.3 DLS Backup Failed

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 500012

    perceivedSeverity Major

    Alarm Description The running DLS backup can not be performed.

    Impact on System The DLS backup fails. The running DLS is not stored in the OMC-Rdatabase.

    The following flowchart describes the associated corrective actions for thisalarm.

    DLS Backup Failed

    Manual backup is ok?

    OMCR

    Alarmsolved

    yes

    Perform a manual backup

    OMCR

    Restart SCPR

    OMCR

    no

    Perform a manual backup

    Manual backup is ok?

    Alarmsolved

    yes

    ContactSystem Support

    no

    Figure 8: DLS Backup Failed: Corrective Actions

    36 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 3 O&M Alarms

    3.4 BSC Autonomous DLS restoration

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 500013

    perceivedSeverity Critical

    Alarm Description Following repetitive BSC process crash, the BSC has autonomouslyrestored a backup DLS considering DLS corruption may be the causeof the crashes.

    Impact on System The BSC autonomously restarts on the new DLS. Telecom & O&Moutage linked to the stop/create of the BSC Application processes.

    The following flowchart describes the associated corrective actions for thisalarm.

    DLS Backup Failed

    OMCR

    Perform a BSSHardware

    Audit

    Alarm cleared? Alarmsolved

    yes

    ContactSystem Support

    no

    Analize the possible

    regressions terms of configuration

    Perform a Radio Force

    Configuration for the BSS

    Figure 9: BSC Autonomous DLS restoration: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 37 / 182

  • 3 O&M Alarms

    3.5 Automatic Abis Programming Disabled

    eventType Equipment

    probableCause OperatorConfigurationOrCustomization

    Alarm Number 500014

    perceivedSeverity Major

    Alarm Description The Programming Mode on Abis is set to "Manual". This parameter iscontrolled from Abis View.

    Impact on System In case of "Manual" Programming Mode on Abis, all Abis modificationcommands passed by the operator are transferred to BSC, checked byBSC but stored only in BSC as future, not programmed configuration.Only when the operator triggers the Abis Programming, themodifications will be brought in force.Note that, during the "Manual" mode of Abis Programming any creationor change performed on Abis elements is immediately consideredas effective on the OMC-R although not yet taken into account in theoperational configuration and thus different from the effective Abistransmission.Differences are visible in TCU - RSL mapping shown in BSSUSMMain View and in TRX - RSL mapping shown in USOD. OMC-R data(corresponding to the future configuration) can be overwritten byeffective Abis transmission data through requesting HSDS Synthesis,TCU Load Report or BSC/BSS audits.On resuming the "Automatic" mode of Abis Programming anyinconsistency is cleared due to the included BSC Hardware Audit andBSC Alarm/State Audit that follow the transmission programming.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Full advantage of manual Abis Programming is taken by groupingcommands relative to the same TSU.Avoid modifications that lead to changing the TCU mode between FRand DR. It will lead to the TCU reset and to traffic outage. If suchmodification is necessary, please trigger the Abis Programming eitherby resuming the "Automatic" mode or by forcing the Abis Programming.Always resume the "Automatic" mode of Abis Programming after thelast Abis operation. Only then, the current alarm is cleared.

    38 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 3 O&M Alarms

    3.6 Errors in checked DLS

    eventType ProcessingError

    probableCause corruptData

    Alarm Number 500015

    perceivedSeverity Warning

    Alarm Description The checked DLS contains error(s).

    Impact on System After the running DLS is backuped, several checks are performed andsome of them fail.

    The following flowchart describes the associated corrective actions for thisalarm.

    Errors in checked DLS

    Alarm cleared? Alarmsolved

    yes

    ContactSystem Support

    no

    Analyse the DLS check report via Log

    Viewer

    Fix the errors found in DLS

    Figure 10: Errors in checked DLS: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 39 / 182

  • 3 O&M Alarms

    3.7 Errors in DLS checks scripts

    eventType ProcessingError

    probableCause corruptData

    Alarm Number 500016

    perceivedSeverity Warning

    Alarm Description The DPCK unitary check scripts contain error(s).

    Impact on System After the running DLS is backuped, several checks are performed andsome of them fail.

    Operator Action Contact your local TAC.

    40 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4 SNMP Class

    This section describes the meaning and corrective actions for each SNMPalarm.

    3BK 21205 AAAA PCZZA Ed.05 41 / 182

  • 4 SNMP Class

    4.1 Loss of Contact with SU

    eventType Communications

    probableCause CommunicationsSubsystemFailure

    Alarm Number 6000099

    perceivedSeverity Critical

    Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.

    42 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    The following flowchart describes the associated corrective actions for thisalarm.

    Loss of Contact with SU

    SU configuration correct?

    Correct SU configuration

    OMCR

    Yes

    Alarmsolved

    ContactSystem Support

    No Yes

    No

    IP network ok?

    No Fix IP network problems

    Yes

    OMCR boards ok? No

    Yes

    Check OMCR boards

    OMCR

    Onsite

    External router ok?

    Fix external router

    problems

    No

    Yes

    SU device ok? Fix SU device problems

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    No

    No

    No

    No

    Yes

    Yes

    Yes

    Yes

    Figure 11: Loss of Contact with SU: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 43 / 182

  • 4 SNMP Class

    4.2 Loss of Contact with SU

    eventType Communications

    probableCause CommunicationsSubsystemFailure

    Alarm Number 6000149

    perceivedSeverity Critical

    Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.

    44 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    The following flowchart describes the associated corrective actions for thisalarm.

    Loss of Contact with SU

    SU configuration correct?

    Correct SU configuration

    OMCR

    Yes

    Alarmsolved

    ContactSystem Support

    No Yes

    No

    IP network ok?

    No Fix IP network problems

    Yes

    OMCR boards ok? No

    Yes

    Check OMCR boards

    OMCR

    Onsite

    External router ok?

    Fix external router

    problems

    No

    Yes

    SU device ok? Fix SU device problems

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    No

    No

    No

    No

    Yes

    Yes

    Yes

    Yes

    Figure 12: Loss of Contact with SU: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 45 / 182

  • 4 SNMP Class

    4.3 Loss of Contact with SU

    eventType Communications

    probableCause CommunicationsSubsystemFailure

    Alarm Number 6000199

    perceivedSeverity Critical

    Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.

    46 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    The following flowchart describes the associated corrective actions for thisalarm.

    Loss of Contact with SU

    SU configuration correct?

    Correct SU configuration

    OMCR

    Yes

    Alarmsolved

    ContactSystem Support

    No Yes

    No

    IP network ok?

    No Fix IP network problems

    Yes

    OMCR boards ok? No

    Yes

    Check OMCR boards

    OMCR

    Onsite

    External router ok?

    Fix external router

    problems

    No

    Yes

    SU device ok? Fix SU device problems

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    No

    No

    No

    No

    Yes

    Yes

    Yes

    Yes

    Figure 13: Loss of Contact with SU: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 47 / 182

  • 4 SNMP Class

    4.4 Loss of Contact with SU

    eventType Communications

    probableCause CommunicationsSubsystemFailure

    Alarm Number 6000249

    perceivedSeverity Critical

    Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.

    48 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    The following flowchart describes the associated corrective actions for thisalarm.

    Loss of Contact with SU

    SU configuration correct?

    Correct SU configuration

    OMCR

    Yes

    Alarmsolved

    ContactSystem Support

    No Yes

    No

    IP network ok?

    No Fix IP network problems

    Yes

    OMCR boards ok? No

    Yes

    Check OMCR boards

    OMCR

    Onsite

    External router ok?

    Fix external router

    problems

    No

    Yes

    SU device ok? Fix SU device problems

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    No

    No

    No

    No

    Yes

    Yes

    Yes

    Yes

    Figure 14: Loss of Contact with SU: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 49 / 182

  • 4 SNMP Class

    4.5 Loss of Contact with SU

    eventType Communications

    probableCause CommunicationsSubsystemFailure

    Alarm Number 6000299

    perceivedSeverity Critical

    Alarm Description Due to a wrong configuration or OMC-R hardware failure or networkerror or SU response time-out, the OMC is not able to communicatewith the SU device.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.

    50 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    The following flowchart describes the associated corrective actions for thisalarm.

    Loss of Contact with SU

    SU configuration correct?

    Correct SU configuration

    OMCR

    Yes

    Alarmsolved

    ContactSystem Support

    No Yes

    No

    IP network ok?

    No Fix IP network problems

    Yes

    OMCR boards ok? No

    Yes

    Check OMCR boards

    OMCR

    Onsite

    External router ok?

    Fix external router

    problems

    No

    Yes

    SU device ok? Fix SU device problems

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    Alarm cleared?

    No

    No

    No

    No

    Yes

    Yes

    Yes

    Yes

    Figure 15: Loss of Contact with SU: Corrective Actions

    3BK 21205 AAAA PCZZA Ed.05 51 / 182

  • 4 SNMP Class

    4.6 SNMP Manager Trapd Daemon Down

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 6000100

    perceivedSeverity Critical

    Alarm Description SNMP Manager Trapd daemon failed.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.The following table describes the associated corrective actions for this alarm.

    Corrective Actions Re-launch the SNMP Manager Trapd daemon.

    4.7 SNMP Manager Trapd Daemon Down

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 6000150

    perceivedSeverity Critical

    Alarm Description SNMP Manager Trapd daemon failed.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.

    Corrective Actions Re-launch the SNMP Manager Trapd daemon.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Re-launch the SNMP Manager Trapd daemon.

    52 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.8 SNMP Manager Trapd Daemon Down

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 6000200

    perceivedSeverity Critical

    Alarm Description SNMP Manager Trapd daemon failed.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.

    Corrective Actions Re-launch the SNMP Manager Trapd daemon.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Re-launch the SNMP Manager Trapd daemon.

    4.9 SNMP Manager Trapd Daemon Down

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 6000250

    perceivedSeverity Critical

    Alarm Description SNMP Manager Trapd daemon failed.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.The following table describes the associated corrective actions for this alarm.

    Corrective Actions Re-launch the SNMP Manager Trapd daemon.

    3BK 21205 AAAA PCZZA Ed.05 53 / 182

  • 4 SNMP Class

    4.10 SNMP Manager Trapd Daemon Down

    eventType ProcessingError

    probableCause SoftwareProgramAbnormallyTerminate

    Alarm Number 6000300

    perceivedSeverity Critical

    Alarm Description SNMP Manager Trapd daemon failed.

    Impact on System The SU device is no more supervised.

    Note: The PerceivedSeverity and additional text are customizable.The following table describes the associated corrective actions for this alarm.

    Corrective Actions Re-launch the SNMP Manager Trapd daemon.

    54 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.11 External Alarm No 1

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000051

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 55 / 182

  • 4 SNMP Class

    4.12 External Alarm No 2

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000052

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    56 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.13 External Alarm No 3

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000053

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 57 / 182

  • 4 SNMP Class

    4.14 External Alarm No 4

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000054

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    58 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.15 External Alarm No 5

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000055

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 59 / 182

  • 4 SNMP Class

    4.16 External Alarm No 6

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000056

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    60 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.17 External Alarm No 7

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000057

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 61 / 182

  • 4 SNMP Class

    4.18 External Alarm No 8

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000058

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    62 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.19 External Alarm No 9

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000059

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 63 / 182

  • 4 SNMP Class

    4.20 External Alarm No 10

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000060

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    64 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.21 External Alarm No 11

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000061

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 65 / 182

  • 4 SNMP Class

    4.22 External Alarm No 12

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000062

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    66 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.23 External Alarm No 13

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000063

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 67 / 182

  • 4 SNMP Class

    4.24 External Alarm No 14

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000064

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    68 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.25 External Alarm No 15

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000065

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 69 / 182

  • 4 SNMP Class

    4.26 External Alarm No 16

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000066

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    70 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.27 External Alarm No 17

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000067

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 71 / 182

  • 4 SNMP Class

    4.28 External Alarm No 18

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000068

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    72 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.29 External Alarm No 19

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000069

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 73 / 182

  • 4 SNMP Class

    4.30 External Alarm No 20

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000070

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    74 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.31 External Alarm No 21

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000071

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 75 / 182

  • 4 SNMP Class

    4.32 External Alarm No 22

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000072

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    76 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.33 External Alarm No 23

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000073

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 77 / 182

  • 4 SNMP Class

    4.34 External Alarm No 24

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000074

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    78 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.35 External Alarm No 1

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000101

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 79 / 182

  • 4 SNMP Class

    4.36 External Alarm No 2

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000102

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    80 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.37 External Alarm No 3

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000103

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 81 / 182

  • 4 SNMP Class

    4.38 External Alarm No 4

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000104

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    82 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.39 External Alarm No 5

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000105

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 83 / 182

  • 4 SNMP Class

    4.40 External Alarm No 6

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000106

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    84 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.41 External Alarm No 7

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000107

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 85 / 182

  • 4 SNMP Class

    4.42 External Alarm No 8

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000108

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    86 / 182 3BK 21205 AAAA PCZZA Ed.05

  • 4 SNMP Class

    4.43 External Alarm No 9

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000109

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm profile.

    3BK 21205 AAAA PCZZA Ed.05 87 / 182

  • 4 SNMP Class

    4.44 External Alarm No 10

    eventType Environmental

    probableCause Indeterminate

    Alarm Number 6000110

    perceivedSeverity Warning

    Alarm Description Depends on alarm profile.Customizable by customer.

    Impact on System Depends on alarm profile.

    Note: The PerceivedSeverity and additional text are customizable.The customer modifies the alarm according to the needs.For each alarm, the following fields are modifiable from UFM:

    Alarm Name

    Additional Text

    Alarm Severity

    Probable Cause.

    The following table describes the associated corrective actions for this alarm.

    Corrective Actions Depends on alarm prof