Aeroflex 4000 NAVCOMM Test Set Operation Manual

Embed Size (px)

Citation preview

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    1/139

    EXPORT CONTROL WARNING: This document contains controlled technology or technical data

    under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot

    be transferred to any foreign third party without the specific prior approval of the U.S. Department

    of Commerce, Bureau of Industry and Security (BIS). Violations of these regulations are punishable

    by fine, imprisonment, or both.

    NAV/COMM Test Set

    IFR 4000Operation Manua

    Issue-

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    2/139

    Subject to Export Control , see Cover Page for detai ls .

    OPERATION MANUAL

    NAV/COMM TEST SET

    IFR 4000

    PUBLISHED BYAerof lex

    COPYRIGHT Aerof lex 2010

    Al l r ights reserved. No part of th is publ icat ion may be reproduced, stored in a ret r ieval system, ort ransmit ted in any form or by any means, e lect ronic, mechanical , photocopying, recording orotherwise wi thout the pr ior permission of the publ isher.

    Reissued Jan 2010

    Issue-2 Mar 2010

    10200 West York / Wichi ta, Kansas 67215 U.S.A. / (316) 522-4981 / FAX (316) 524-2623

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    3/139

    OPERATION MANUALIFR 4000

    Subject to Export Control , see Cover Page for detai ls .

    Electromagnetic Compatibi l i ty:

    For cont inued EMC compl iance, a l l external cables must be shie lded and three meters or less inlength.

    Nomenclature Statement:

    In th is manual IFR 4000, 4000, Test Set or Uni t refers to the IFR 4000 NAV/COMM Test Set .

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    4/139

    OPERATION MANUALIFR 4000

    Subject to Export Control , see Cover Page for detai ls .

    THIS PAGE INTENTIONALLY LEFT BLANK.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    5/139

    OPERATION MANUALIFR 4000

    Subject to Export Control , see Cover Page for detai ls .

    SAFETY FIRST: TO ALL OPERATIONS PERSONNEL

    REFER ALL SERVICING OF UNIT TO QUALIFIED TECHNICAL PERSONNEL. THIS UNIT CONTAINS NOOPERATOR SERVICEABLE PARTS.

    WARNING: USING THIS EQUIPMENT IN A MANNER NOT SPECIFIED BY THE ACCOMPANYINGDOCUMENTATION MAY IMPAIR THE SAFETY PROTECTION PROVIDED BY THE EQUIPMENT.

    CASE, COVER OR PANEL REMOVAL

    Opening the Case Assembly exposes the opera tor to e lec t r ica l hazards tha t can resu l t in e lec t r ica l shock orequ ipment damage. Do not opera te th is Tes t Set wi th the Case Assembly open.

    SAFETY IDENTIFICATION IN TECHNICAL MANUAL

    This manual uses the fo l low ing terms to draw a t ten t ion to poss ib le sa fe ty hazards , tha t may ex is t whenopera t ing or serv ic ing th is equ ipment .

    CAUTION: THIS TERM IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT INEQUIPMENT OR PROPERTY DAMAGE (E .G. , F IRE) .

    WARNING: THIS TERM IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT INPERSONAL INJURY OR DEATH.

    SAFETY SYMBOLS IN MANUALS AND ON UNITS

    CAUTION: Refer to accompany ing documents . (Th is symbol re fers tospec i f ic CAUTIONS represented on the un i t and c lar i f ied in the tex t . )

    AC OR DC TERMINAL: Termina l tha t may supp ly or be supp l ied w i t h AC orDC vo l tage.

    DC TERMINAL: Termina l tha t may supp ly or be supp l ied w i th DC vo l tage.

    AC TERMINAL: Termina l tha t may supp ly or be supp l ied w i t h AC ora l te rnat ing vo l tage.

    EQUIPMENT GROUNDING PRECAUTION

    Improper ground ing o f equ ipment can resu l t in e lec t r ica l shock .

    USE OF PROBES

    Check the spec i f ica t ions f o r the max imum vo l tage, cur rent and power ra t ings o f any connec tor on the Tes tSet before connec t ing i t w i th a probe f rom a term ina l dev ice . Be sure the te rm ina l dev ice per forms w i th inthese spec i f ica t ions before us ing i t fo r measurement , to prevent e lec t r ica l shock or damage to theequ ipment .

    POWER CORDS

    Power cords must not be f rayed, broken nor expose bare w i r ing when opera t ing t h is equ ipment .

    USE RECOMMENDED FUSES ONLY

    Use on ly fuses spec i f ica l ly recommended for the equ ipment a t the spec i f ied cur rent and vo l tage ra t ings .

    INTERNAL BATTERY

    This un i t conta ins a L i th ium Ion Bat tery , serv iceab le on ly by a qua l i f ied techn ic ian .

    CAUTION: SIGNAL GENERATORS CAN BE A SOURCE OF ELECTROMAGNETIC INTERFERENCE (EMI) TOCOMMUNICATION RECEIVERS. SOME TRANSMITTED SIGNALS CAN CAUSE DISRUPTIONAND INTERFERENCE TO COMMUNICATION SERVICES OUT TO A DISTANCE OF SEVERALMILES. USERS OF THIS EQUIPMENT SHOULD SCRUTINIZE ANY OPERATION THAT RESULTSIN RADIATION OF A S I GNAL (DIRECTLY OR INDIRECTLY) AND SHOULD TAKE NECESSARYPRECAUTIONS TO AVOID POTENTIAL COMMUNICATION INTERFERENCE PROBLEMS.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    6/139

    OPERATION MANUALIFR 4000

    Subject to Export Control , see Cover Page for detai ls .

    THIS PAGE INTENTIONALLY LEFT BLANK.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    7/139

    OPERATION MANUALIFR 4000

    Subject to Export Control , see Cover Page for detai ls .

    DECLARATION OF CONFORMITY

    The Declaration of Conformity Certif icate include d withthe unit should remain with the unit.

    Aeroflex recommends the operator reproduce a copy ofthe Declaration of Conformity Certif icate to be storedwith the Operation Manual for future reference.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    8/139

    OPERATION MANUALIFR 4000

    Subject to Export Control , see Cover Page for detai ls .

    THIS PAGE INTENTIONALLY LEFT BLANK.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    9/139

    OPERATION MANUALIFR 4000

    TABLE OF CONTENTSSubject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    TABLE OF CONTENTS

    Ti t le Chapter/Sect ion

    Ti t le / Copyr ight PageStatementsSafety PageDeclarat ion of Conformi tyTable of ContentsInt roduct ionService Upon Receipt of Mater ia l

    Chapter 1

    Sect ion 1 - Descr ipt ion 1-1Sect ion 2 - Operat ion 1-2Sect ion 3 - Speci f icat ions 1-3Sect ion 4 - Shipping 1-4Sect ion 5 - Storage 1-5

    Appendix A - Connector P in-Out TablesAppendix B - Metr ic/Br i t ish Imper ia l Conversion Table wi th Naut ical Distance ConversionsAppendix C - Factory PresetsAppendix D - Abbreviat ionsAppendix E - Ser ia l Inter face CableAppendix F - 406 Beacon Appl icat ions and Protocols

    Index

    Bat tery/Vol tage Inst ruct ions

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    10/139

    OPERATION MANUALIFR 4000

    TABLE OF CONTENTSSubject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    THIS PAGE INTENTIONALLY LEFT BLANK.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    11/139

    OPERATION MANUALIFR 4000

    INTRODUCTIONPage 1

    Mar 1/10

    INTRODUCTION

    This manual contains operat ing inst ruct ions for the IFR 4000. I t is st rongly recommended thatpersonnel be thoroughly fami l iar wi th the contents of th is manual before at tempt ing to operate th isequipment .

    Refer a l l servic ing of uni t to qual i f ied technical personnel .

    ORGANIZATION

    This manual is d iv ided into the fo l lowing Chapters and Sect ions:

    CHAPTER 1 - OPERATION

    Sect ion 1 - DESCRIPTION

    Sect ion 2 - OPERATION ( insta l lat ion; descr ipt ion of cont ro ls, connectors and indicators;performance evaluat ion; operat ing procedures)

    Sect ion 3 - SPECIFICATIONS

    Sect ion 4 - SHIPPING

    Sect ion 5 - STORAGE

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    12/139

    OPERATION MANUALIFR 4000

    INTRODUCTIONPage 2

    Mar 1/10

    THIS PAGE INTENTIONALLY LEFT BLANK.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    13/139

    OPERATION MANUALIFR 4000

    1-TABLE OF CONTENTSSubject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    CHAPTER ONE

    IFR 4000 NAV/COMM TEST SET

    OPERATION MANUAL

    TABLE OF CONTENTS

    Ti t le Chapter/Sect ion/Subject Page

    SECTION 1 - DESCRIPTION 1-1

    1. General Descr ipt ion and Capabi l i t ies 1-1-1 11.1 Descr ipt ion 1-1-1 11.2 Funct ional Capabi l i t ies 1-1-1 1

    SECTION 2 - OPERATION 1-2

    1. Insta l lat ion 1-2-1 11.1 General 1-2-1 11.2 Bat tery Operat ion 1-2-1 1

    1.3 Bat tery Charging 1-2-1 11.4 Safety Precaut ions 1-2-1 1

    1.4.1 Complying wi th Inst ruct ions 1-2-1 11.4.2 Grounding Power Cord 1-2-1 11.4.3 Operat ing Safety 1-2-1 1

    1.5 AC Power Requirements 1-2-1 21.6 Bat tery Recharging 1-2-1 21.7 External Cleaning 1-2-1 3

    2. Cont ro ls, Connectors and Indicators 1-2-2 13. Performance Evaluat ion 1-2-3 1

    3.1 General 1-2-3 13.2 Sel f Test 1-2-3 1

    4. Operat ing Procedures 1-2-4 14.1 General 1-2-4 14.2 Screen Descr ipt ions 1-2-4 2

    4.2.1 Startup Screen 1-2-4 24.2.2 Setup Menu 1-2-4 34.2.3 Guided Test Screens 1-2-4 44.2.4 Store/Recal l Screens 1-2-4 64.2.5 Hardware Tools Screen 1-2-4 74.2.6 RS-232 Set t ings Screen 1-2-4 84.2.7 Diagnost ics Screen 1-2-4 84.2.8 Sel f Test Screen 1-2-4 94.2.9 Cal ibrat ion Screen 1-2-4 104.2.10 Info Screen 1-2-4 104.2.11 VOR Mode Screen 1-2-4 114.2.12 Local izer Mode Screen 1-2-4 134.2.13 Gl ideslope Mode Screen 1-2-4 154.2.14 Marker Beacon Mode Screen 1-2-4 17

    4.2.15 ILS Mode Screen 1-2-4 184.2.16 COMM AM Mode Screen 1-2-4 214.2.17 COMM FM Mode Screen 1-2-4 234.2.18 COMM SSB Mode Screen 1-2-4 254.2.19 PWR MTR ZERO Screen 1-2-4 274.2.20 SWR Mode Screen 1-2-4 274.2.21 SELCAL Mode Screen 1-2-4 304.2.22 Frequency Counter Mode Screen 1-2-4 314.2.23 121.5/243 BEACON Mode Screen 1-2-4 324.2.24 406 BEACON Mode Screen 1-2-4 33

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    14/139

    OPERATION MANUALIFR 4000

    1-TABLE OF CONTENTSSubject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    Ti t le Chapter/Sect ion/Subject Page

    SECTION 2 - OPERATION (cont)

    4. Operat ing Procedures (cont )4.3 General Operat ing Informat ion 1-2-4 41

    4.2.1 Startup Screen 1-2-4 414.2.2 Setup Menu 1-2-4 414.2.3 VOR Mode 1-2-4 424.2.4 Local izer Mode 1-2-4 444.2.5 Gl ideslope Mode 1-2-4 464.2.6 Marker Beacon Mode 1-2-4 484.2.7 ILS Mode 1-2-4 494.2.8 COMM AM Mode 1-2-4 504.2.9 COMM FM Mode 1-2-4 524.2.10 COMM SSB Mode 1-2-4 544.2.11 SWR Mode 1-2-4 564.2.12 SELCAL Mode 1-2-4 574.2.13 Frequency Counter Mode 1-2-4 584.2.14 121.5/243 BEACON Mode Screen 1-2-4 594.2.15 406 BEACON Mode Screen 1-2-4 60

    4.4 Guided Test 1-2-4 60

    4.4.1 Creat ing a Sequence 1-2-4 604.4.2 Delet ing a Sequence 1-2-4 624.4.3 P laying a Sequence 1-2-4 634.4.4 Download Sequences through a Remote

    Connect ion 1-2-4 634.4.5 Upload Sequences through a Remote

    Connect ion 1-2-4 64

    SECTION 3 - SPECIFICATIONS 1-3

    SECTION 4 - SHIPPING 1-4

    1. Shipping Test Sets 1-4-1 1

    1.1 Informat ion 1-4-1 11.2 Repacking Procedure 1-4-1 1

    SECTION 5 - STORAGE 1-5

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    15/139

    OPERATION MANUALIFR 4000

    1-LIST OF ILLISTRATIONSSubject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    LIST OF ILLUSTRATIONS

    Ti t le Chapter/Sect ion/Subject Page

    Bat tery Recharging 1-2-1 2IFR 4000 Front Panel 1-2-2 1Analog CDI wi th 5 Dot ILS Deviat ion 1-2-4 45EFIS wi th 2 1/2 Dot ILS Deviat ion 1-2-4 45Repacking Procedure 1-4-1 1

    LIST OF TABLES

    Ti t le Chapter/Sect ion/Subject Page

    Sel f Test Fai lures 1-2-3 2406 BEACON Message Fie lds 1-2-4 38

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    16/139

    OPERATION MANUALIFR 4000

    1-LIST OF ILLISTRATIONSSubject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    THIS PAGE INTENTIONALLY LEFT BLANK.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    17/139

    OPERATION MANUALIFR 4000

    1-SERVICE UPON RECEIPTSubject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    SERVICE UPON RECEIPT OF MATERIAL

    Unpacking

    Special -design packing mater ia l inside th is sh ipping carton provides maximum protect ion for theIFR 4000. Avoid damaging the carton and packing mater ia l dur ing equipment unpacking. Use thefol lowing steps for unpacking the IFR 4000.

    Cut and remove the seal ing tape on the carton top and open the carton.

    Grasp the IFR 4000 t ransi t case f i rmly, whi le rest ra in ing the shipping carton, and l i f t theequipment and packing mater ia l vert ical ly.

    Place the IFR 4000 t ransi t case and end cap packing on a sui table f lat , c lean and dry s urface.

    Remove the protect ive plast ic bag f rom the IFR 4000 t ransi t case. P lace protect ive plast ic bagand end cap packing mater ia l inside shipping carton. Store the shipping carton for future useshould the IFR 4000 need to be returned.

    Checking Unpacked Equipment

    Inspect the equipment for damage incurred dur ing shipment . I f the equipment has beendamaged, report the damage to Aerof lex.

    Check the equipment against the packing sl ip to see i f the shipment is complete. Report a l ld iscrepancies to Aerof lex.

    DESCRIPTION PART NUMBER STANDARD/OPTIONAL QTY

    IFR 4000 STANDARD 1

    AC/DC POWER SUPPLY 67366 (7110-5600-200) STANDARD 1

    VHF/UHF MULTI-BAND ANTENNA 9140 (1201-5601-000) STANDARD 1

    ANTENNA 9137 (1201-0909-900) STANDARD 1

    TNC (MALE - MALE) COAXIAL CABLE 62398 (6041-5680-800) STANDARD 1

    TNC SHORT 24140 (2289-0001-009) STANDARD 1

    50 LOAD 24141 (2289-0001-010) STANDARD 1

    5 A FUSE 56080 (5106-0000-057) STANDARD 1

    TRANSIT CASE 10238 (1412-5653-000) STANDARD 1

    POWER CORD (110 USE) (US ONLY) 62302 (6041-0001-000) STANDARD 1ANTENNA INSTRUCTIONS (PAPER) 6085 (1002-5600-8P0) STANDARD 1

    PASSWORD CARD (PAPER) 6086 (1002-5600-9P0) STANDARD 1

    OPERATION MANUAL (CD-ROM) 6081 (1002-5600-2C0) STANDARD 1

    MAINTENANCE MANUAL (CD-ROM) 6083 (1002-5600-4C0) OPTIONAL

    RS-232 INTERFACE CABLE (15-P IN) 62399 (6041-5680-900) OPTIONAL

    RS-232 INTERFACE CABLE (25-P IN) 62400 (6041-5681-200) OPTIONAL

    BENCH STAND 63656 (6500-5681-000) OPTIONAL

    POWER CORDS (220 USE) 64020 (7001-9903-000) OPTIONAL

    STANDARD EQUIPMENT OPTIONAL EQUIPMENT

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    18/139

    OPERATION MANUALIFR 4000

    1-SERVICE UPON RECEIPTSubject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    THIS PAGE INTENTIONALLY LEFT BLANK.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    19/139

    OPERATION MANUALIFR 4000

    1-1-1Subject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    SECTION 1 - DESCRIPTION

    1. GENERAL DESCRIPTION AND CAPABILITIES

    1.1 DESCRIPTION

    MODE RF LVL

    FREQ TONE

    M MOD SETUP

    LOC G/S

    DDM / uA

    CTRS

    BKLT

    DISPLAY

    CHARGE

    POWER

    056P-07

    The IFR 4000 is a F l ight L ine or Ramp Test Setfor test ing ILS, VOR, Marker Beacon,HF/VHF/UHF Communicat ions (NAV/COMM)Systems, and wi th the ELT Opt ion,121.5/243 MHz Short Range EmergencyBeacons and 406 MHz COSPAS/SARSAT LongRange Emergency Beacons.

    The IFR 4000 is designed for ease of use,portabi l i ty , re l iabi l i ty and long service l i fe.The IFR 4000 may also be used for benchtest ing in the General Aviat ion envi ronment .

    Power is der ived f rom an internal bat tery. For

    DC input , the DC POWER Connector isprovided for bat tery charging, bench operat ionor servic ing use.

    The IFR 4000 and suppl ied accessor ies arestored in a Ruggedized Plast ic TransportCase.

    1.2 FUNCTIONAL CAPABILITIES

    The IFR 4000 has the fo l lowing features andcapabi l i t ies:

    Accurate measurements of VHF/UHFtransmit ter f requency, output power,modulat ion (AM and FM) and receiversensi t iv i ty.

    Accurate measurements of HF t ransmit terf requency, output power, modulat ion (AM)and SSB USB/LSB receiver sensi t iv i ty.

    Generat ion of ARINC 596 Select ive Cal l ingTones.

    Accurate measurement of VHF/UHFantenna and or feeder SWR (StandingWave Rat io) .

    Simulat ion of Local izer and Gl ideslope(CAT I , I I and I I I ) S ignals wi th var iableDDM set t ings.

    Swept Local izer DDM for coupled Auto P i lottest ing. (S imul taneous Local izer,Gl ideslope and Marker s ignals. )

    Simulat ion of VOR beacon wi th var iablebear ing.

    Simulat ion of Marker Beacon, Selectable

    Airways (Z), Outer and Middle MarkerTones.

    Guided Test capabi l i ty a l lows inst rumentsetup steps to be stored.

    Accurate measurement of 121.5/243 Hzemergency beacon t ransmit ter f requency,output power and modulat ion (AM). Audiooutput for headphones to moni tor swepttone. (p/o ELT Opt ion)

    Accurate measurement of 406 MHzCOSPAS/SARSAT beacon t ransmit terf requency and output power. Decodes and

    displays al l locat ion and user protocols.(p/o ELT Opt ion)

    Large LCD Display wi th user adjustableBackl ight and Contrast .

    Internal Bat tery a l lows eight hoursoperat ion before recharge.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    20/139

    OPERATION MANUALIFR 4000

    1-1-1Subject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    1.2 FUNCTIONAL CAPABILITIES (cont)

    Automat ic power shutdown af terapproximately 5 to 20 minutes (selectable)of non-use when AC power is notconnected.

    Compact and l ightweight enough to a l lowfor one person operat ion.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    21/139

    OPERATION MANUALIFR 4000

    1-2-1Subject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    SECTION 2 - OPERATION

    1. INSTALLATION

    1.1 GENERAL

    The IFR 4000 is powered by an internalL i th ium Ion bat tery pack. The Test Set issuppl ied wi th an external DC Power Supplythat enables the operator to recharge thebat tery when connected to AC power.

    NOTE: The IFR 4000 can operatecont inuously on AC power v ia the DCPower Supply, for servic ing and/orbench tests.

    Refer to 1-2-2, F igure 2 for locat ion ofcont ro ls, connectors or indicators.

    1.2 BATTERY OPERATION

    The internal bat tery is equipped to power theIFR 4000 for e ight hours of cont inuous use,af ter which t ime, the IFR 4000 bat tery nee dsrecharging. Bat tery Operat ion T ime Remaining( in Hours) is d isplayed on al l screens.

    The IFR 4000 contains an automat ic t ime-outto conserve power. I f a key is not pressedwi th in a 5 to 20 minute t ime per iod, the TestSet shuts Of f (only when using bat tery power) .The Power Down Time may be set in the SetupScreen.

    1.3 BATTERY CHARGING

    The bat tery charger operates whenever DCpower (11 to 32 Vdc) is appl ied to the Test Setwi th the suppl ied DC Power Supply or asui table DC power source. When charging, thebat tery reaches an 100% charge inapproximately four hours. The internal bat terycharger a l lows the bat tery to charge between a

    temperature range of 5 to 40C. TheIFR 4000 can operate, connected to anexternal DC source, outside the bat tery

    charging temperature range (5 to 40C).

    The bat tery should be charged every threemonths (minimum) or d isconnected for long

    term inact ive storage per iods of more thansix months. The Bat tery must be removedwhen condi t ions surrounding the Test Set are

    60C)

    1.4 SAFETY PRECAUTIONS

    The fo l lowing safety precaut ions must beobserved dur ing insta l lat ion and operat ion.Aerof lex assumes no l iabi l i ty for fa i lure tocomply wi th any safety precaut ion out l ined inth is manual .

    1.4.1 Complying with Instructions

    Insta l lat ion/operat ing personnel should notat tempt to insta l l or operate the IFR 4000wi thout reading and complying wi thinst ruct ions contained in th is manual . A l lprocedures contained in th is manual must beperformed in exact sequence and manner

    descr ibed.

    1.4.2 Grounding Power Cord

    WARNING: DO NOT USE A THREE-PRONGTO TWO-PRONG ADAPTERPLUG. DOING SO CREATES ASHOCK HAZARD BETWEEN THECHASSIS AND ELECTRICALGROUND.

    For AC operat ion, the AC Line Cable,connected to the DC Power Supply, isequipped wi th standard three-prong plug andmust be connected to a proper ly groundedthree-prong receptacle that is easi lyaccessib le. I t is the customer 's responsib i l i tyto :

    Have a qual i f ied elect r ic ian checkreceptacle(s) for proper grounding.

    Replace any standard two-prongreceptacle(s) wi th proper ly grounded three-prong receptacle(s) .

    1.4.3 Operating Safety

    Due to potent ia l for e lect r ical shock wi th in theTest Set , the Case Assembly must be clos edwhen the Test Set is connected to an external

    power source.

    Bat tery replacement , fuse replacement andinternal adjustments must only be performedby qual i f ied service technic ians.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    22/139

    OPERATION MANUALIFR 4000

    1-2-1Subject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    1.5 AC POWER REQUIREMENTS

    The DC Power Supply, suppl ied wi th theIFR 4000, operates over a vol tage range of100 to 250 VAC at 47 to 63 Hz.

    The bat tery charger operates whenever DC

    power (11 to 32 Vdc) is appl ied to the Test Setwi th the suppl ied DC Power Supply or asui table DC power source. When charging, thebat tery reaches an 100% charge inapproximately four hours. The Bat tery

    Charging temperature range is 5 to 40C,cont ro l led by an internal bat tery charger.

    1.6 BATTERY RECHARGING

    Refer to 1-2-1, F igure 1.

    STEP PROCEDURE

    1. Connect AC Line Cable to e i ther:

    AC PWR Connector on the DC PowerSupply and an appropr iate AC powersource

    Sui table DC power source

    2. Connect the DC Power Supply to the DCPOWER Connector on the IFR 4000.

    3. Ver i fy the CHARGE Indicator i l luminatesyel low.

    4. A l low four hours for bat tery charge orunt i l the CHARGE Indicator i l luminatesgreen.

    NOTE: I f the CHARGE Indicator f lashesyel low and/or the bat tery fa i ls toaccept a charge and theIFR 4000 does not operate onbat tery power, the bat tery,serviceable only by a qual i f iedtechnician, requi resreplacement . Refer toBat tery/Vol tage Inst ruct ions.

    DC POWER

    SUPPLY

    YELLOW

    (CHARGING)

    YELLOW - FLASHING

    (FAULTY BATTERY)

    056P-01

    (CHARGED)

    GREEN

    Bat tery RechargingFigure 1

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    23/139

    OPERATION MANUALIFR 4000

    1-2-1Subject to Export Control , see Cover Page for detai ls . Page 3

    Mar 1/10

    1.7 EXTERNAL CLEANING

    The fo l lowing procedure contains rout ineinst ruct ions for c leaning the outside of theTest Set .

    CAUTION: DISCONNECT POWER FROM

    TEST SET TO AVOID POSSIBLEDAMAGE TO ELECTRONICCIRCUITS.

    STEP PROCEDURE

    1. Clean front panel but tons and displayface wi th sof t l in t - f ree cloth. I f d i r t isdi f f icul t to remove, dampen cloth wi thwater and a mi ld l iquid detergent .

    2. Remove grease, fungus and ground- indi r t f rom surfaces wi th sof t l in t - f ree clothdampened (not soaked) wi th isopropyla lcohol .

    3. Remove dust and di r t f rom connectorswi th sof t -br ist led brush.

    4. Cover connectors, not in use, wi thsui table dust cover to prevent tarnishingof connector contacts.

    5. Clean cables wi th sof t l in t - f ree cloth.

    6. Paint exposed metal surface to avoidcorrosion.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    24/139

    OPERATION MANUALIFR 4000

    1-2-1Subject to Export Control , see Cover Page for detai ls . Page 4

    Mar 1/10

    THIS PAGE INTENTIONALLY LEFT BLANK.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    25/139

    OPERATION MANUALIFR 4000

    1-2-2Subject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    2. CONTROLS, CONNECTORS AND INDICATORS

    MODE RF LVL

    FREQ TONE

    M MOD SETUP

    LOC G/S

    DDM / uA

    CTRS

    BKLT

    DISPLAY

    CHARGE

    POWER

    ANTRF I/OAUX I/OSWR

    TE

    REMOTE

    RE

    1 2 3 4 5

    7

    11

    19

    20

    21

    22

    26

    27

    25

    24

    23

    18

    16

    17

    15

    14

    13

    12

    10

    9

    8

    056P-06

    6

    IFR 4000 Front PanelF igure 2

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    26/139

    OPERATION MANUALIFR 4000

    1-2-2Subject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    NUMERICAL LOCATION LIST ALPHABETICAL LOCATION LIST

    1. SWR Connector

    2. AUX I /O Connector

    3. DC POWER Connector

    4. RF I /O Connector

    5. ANT Connector

    6. REMOTE Connector

    7. Display

    8. Mul t i -Funct ion Sof t Keys

    9. MODE Select Key

    10. RF LVL Fie ld Select Key

    11. FREQ Field Select Key

    12. TONE Field Select Key

    13. M MOD Field Select Key

    14. SETUP Key

    15. G/S DDM UP Key

    16. LOC DDM LEFT Key

    17. G/S DDM DOWN Key

    18. LOC DDM RIGHT Key

    19. BACKLIGHT Key

    20. POWER Key

    21. POWER Indicator

    22. CHARGE Indicator

    23. CONTRAST Key

    24. DECREMENT/SELECT Data Key

    25. SELECT DATA UNIT MSB Key

    26. SELECT DATA UNIT LSB Key

    27. INCREMENT/SELECT Data Key

    ANT Connector 5

    AUX I /O Connector 2

    BACKLIGHT Key 19

    CHARGE Indicator 22

    CONTRAST Key 23

    DC POWER Connector 3

    DECREMENT/SELECT Data Key 24

    Display 7

    FREQ Field Select Key 11

    G/S DDM DOWN Key 17

    G/S DDM UP Key 15

    INCREMENT/SELECT Data Key 27

    LOC DDM LEFT Key 16

    LOC DDM RIGHT Key 18

    M MOD Field Select Key 13

    MODE Select Key 9

    Mul t i -Funct ion Sof t Keys 8

    POWER Indicator 21

    POWER Key 20

    RF I /O Connector 4

    REMOTE Connector 6

    RF LVL Fie ld Select Key 10

    SELECT DATA UNIT LSB Key 26

    SELECT DATA UNIT MSB Key 25

    SETUP Key 14

    SWR Connector 1

    TONE Field Select Key 11

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    27/139

    OPERATION MANUALIFR 4000

    1-2-2Subject to Export Control , see Cover Page for detai ls . Page 3

    Mar 1/10

    ITEM DESCRIPTION

    1. SWR Connector

    TNC Type Connector used for VSWRmeasurements on Antenna and FeederSystems.

    2. AUX I /O Connector

    BNC Type Connector for output ofbaseband modulat ion and 10 MHzreference and for counter input .

    3. DC POWER Connector

    Circular Type Connector (2.5 mm center,5.5 mm outer d iameter, center posi t ive)used for bat tery charging or operat ion ofTest Set .

    4. RF I /O Connector

    TNC Type Connector used for d i rect

    conect to the UUT for power andf requency measurements for COMMtest ing, and for provid ing RF st imulas forVOR/ILS/GS/MB receivers.

    5. ANT Connector

    BNC Type Connector used for over- the-ai r st imulas for VOR/ILS/GS/MBreceivers and for COMM test ing.

    6. REMOTE Connector

    DB15 Type Connector or DB25 TypeConnector used for remote operat ion andsof tware upgrades. Contains RS-232,USB Host and USB Per ipheralconnect ions.

    7. Display (LCD)

    38 characters by 16 l ines for main screendisplay wi th Sof t Key boxes at the bot tomof the screen.

    8. Mul t i -Funct ion Sof t Keys

    Five Sof t Keys are provided. Thelegends are displayed in boxes at thebot tom of the Display.

    9. MODE Select Key

    This Key enters the MODE Field andselects the operat ional mode ( i .e. , VOR,Local izer, etc. ) .

    ITEM DESCRIPTION

    10. RF LVL Fie ld Select Key

    This Key moves the edi t cursor to the RFLVL (RF Level ) F ie ld.

    The INCREMENT/SELECT Data Key or

    the DECREMENT/SELECT Data Key maybe used to s lew the RF Level .

    The SELECT DATA UNITS MSB Key orthe SELECT DATA UNITS LSB Key maybe used to select the RF LVL uni ts to beslewed ( i .e. , 0.1 dB, 1 dB, etc. ) .

    11. FREQ Field Select Key

    This Key moves the edi t cursor to theFREQ (Frequency) F ie ld.

    The INCREMENT/SELECT Data Key orthe DECREMENT/SELECT Data Key maybe used to s lew the data.

    The SELECT DATA UNITS MSB Key orthe SELECT DATA UNITS LSB Key maybe used to select the FREQ uni ts to beslewed ( i .e. , 25 kHz, 100 kHz, etc. ) .

    12. TONE Field Select Key

    This Key moves the edi t cursor to theMOD TONE Field.

    The INCREMENT/SELECT Data Key orthe DECREMENT/SELECT Data Key maybe used to s lew the data.

    13. M MOD Field Select Key

    This Key moves the edi t cursor to the MMOD (Master Modulat ion) F ie ld and turnsthe modulat ion OFF (0%) or ON (CAL).

    The INCREMENT/SELECT Data Key orthe DECREMENT/SELECT Data Key maybe used to s lew the modulat ion depth.

    14. SETUP Key

    This Key displays the SETUP Menu.

    15. G/S DDM UP Key

    This Key slews the displayed Gl ideslopeDDM Up.

    Increments are ei ther FIXED or VAR(Var iable) depending on the DDM DEVSTEP Field set t ing.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    28/139

    OPERATION MANUALIFR 4000

    1-2-2Subject to Export Control , see Cover Page for detai ls . Page 4

    Mar 1/10

    ITEM DESCRIPTION

    16. LOC DDM LEFT Key

    This Key slews the displayed Local izerDDM to the Lef t .

    Increments are ei ther FIXED or VAR

    (Var iable) depending on the DDM DEVSTEP Field set t ing.

    17. G/S DDM DOWN Key

    This Key slews the displayed Gl ideslopeDDM Down.

    Increments are ei ther FIXED or VAR(Var iable) depending on the DDM DEVSTEP Field set t ing.

    18. LOC DDM RIGHT Key

    This Key slews the displayed Local izerDDM to the Right .

    Increments are ei ther FIXED or VAR(Var iable) depending on the DDM DEVSTEP Field set t ing.

    19. BACKLIGHT Key

    This Key displays/exi ts the Backl ightAdjust F ie ld.

    The INCREMENT/SELECT Data Key orthe DECREMENT/SELECT Data Key maybe used to adjust the Backl ight Intensi ty.

    The IFR 4000 powers up wi th theBackl ight set to the set t ing of theprevious session.

    20. POWER Key

    This Key powers the IFR 4000 up anddown.

    21. POWER Indicator

    This Indicator is i l luminated when theIFR 4000 is powered.

    22. CHARGE Indicator

    This Indicator is i l luminated whenexternal DC power is appl ied for BenchOperat ion or Bat tery charging.

    This Indicator is yel low when the bat teryis charging, f lashing yel low when thebat tery needs replacing and Green whenthe bat tery is fu l ly charged.

    ITEM DESCRIPTION

    23. CONTRAST Key

    This Key displays/exi ts the Cont rastAdjust F ie ld.

    The INCREMENT/SELECT Data Key or

    the DECREMENT/SELECT Data Key maybe used to adjust the Cont rast .

    24. DECREMENT/SELECT Data Key

    This Key decrements data in s lewablef ie lds, such as FREQ. This Key alsoselects data in f ie lds that have f ixedfunct ions, such as MOD TONE andMODE.

    25. SELECT DATA UNIT MSB Key

    This Key moves the slew cursor towardthe MSB (Most S igni f icant B i t ) of thedata f ie ld.

    Example: When a var iable f requency isselected, the slew cursorcan be moved f rom the1 kHz uni t to the 10 kHzuni t .

    26. SELECT DATA UNIT LSB Key

    This Key moves the slew cursor towardthe LSB (Least S igni f icant B i t ) of thedata f ie ld.

    Example: When a var iable f requency isselected, the slew cursorcan be moved f rom the

    10 kHz uni t to the 1 kHzuni t .

    27. INCREMENT/SELECT Data Key

    This Key increments data in s lewablef ie lds, such as FREQ. This Key alsoselects data in f ie lds that have f ixedfunct ions, such as MOD TONE andMODE.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    29/139

    OPERATION MANUALIFR 4000

    1-2-3Subject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    3. PERFORMANCE EVALUATION

    3.1 GENERAL

    The IFR 4000 is equipped wi th a Sel f Test forquick performance evaluat ion. An abbreviated

    Sel f Test is run at Power-Up. The fu l l Sel fTest is in i t ia ted manual ly.

    Refer to 1-2-2, F igure 2 for locat ion ofcont ro ls, connectors and indicators.

    3.2 SELF TEST

    STEP PROCEDURE

    1. Press the SETUP Key to d isplay theSetup Menu.

    B AT 1 .2 H r

    PORT: FREQ:PRESET

    AP SWP RATE :20 sec VOR BRG :F IXED

    E X T A T T N : 0 .0 d B P WR D WN :1 0 min s

    ILS UNITS :DD M RF LVL UNITS:dBm

    K E Y C L IC K :O F F M O RS E C O D E : IF R

    AUDIO:OFF

    N E X T

    P A R A M

    G U I D E D

    T E S T

    S T O R E /

    R E C A L L

    S E T U P

    H / W

    T O O L S

    RF I /O

    I N F O

    2. Press the H/W TOOLS Sof t Key todisplay the Hardware Tools Screen.

    B A T 1.2 Hr

    RS232 CAL

    H A R D WA R E T O OL S

    R ETUR N

    DIAGS

    S/N 999999999

    M IC R O V E R 1 .2M IC R O O P T 1

    STEP PROCEDURE

    3. Press the DIAGS Sof t Key to d isplay theDiagnost ics Screen.

    BAT 1 .2 Hr

    S E L F

    T E S T

    DIAGNOSTICS

    R E T U R N

    AMBIENT TEMPERATURE = 84 F 29 C

    RF BLO CK TEMPERATURE = 82 F 28 C

    4. Press the SELFTEST Sof t Key to d isplaythe Sel f Test Screen.

    R U N

    S E L F T E S T

    R E T U R N

    - - - -- - - -- - - -- - - -

    - - - -- - - -- - - -

    - - - -

    Lock DetLv l DetS WRF r e q C t r

    L o c a l i z e rM a r k e rPwr Det

    A n t P r o t

    - - - -- - - -- - - -- - - -

    - - - -- - - -- - - -

    - - - -

    R A MFlashCPLDN V R A M

    F P G AU SBKeypad

    B a t te r y

    BAT 1.2 Hr

    D is c o n n e c t c a b le s f r o m p o r tsb e fo r e r u n n in g s e l f t e s t

    The Sel f Test cannot be performed unt i lthe IFR 4000 has f in ished the warm-upcycle. I f the user at tempts to in i t ia te theSel f Test before the IFR 4000 is ready,the fo l lowing message is d isplayed:

    Instrument warming upPlease wai t xx secs

    The message counts down to zero (0)then the Sel f Test can be in i t ia ted.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    30/139

    OPERATION MANUALIFR 4000

    1-2-3Subject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    3.2 SELF TEST (cont)

    STEP PROCEDURE

    5. Press the RUN Sof t Key to in i t ia te theSel f Test .

    S E L F T E S T

    A B OR T

    P A S SP A S SP A S ST E S T- - - -- - - -- - - -- - - -

    - - - -

    Lock DetLv l DetS WRF r e q C t rL o c a l i z e rM a r k e rPwr Det

    A n t P r o t

    - - - -- - - -- - - -- - - -- - - -- - - -- - - -

    - - - -

    R A MFlashCPLDN V R A MF P G AU SBKeypadB a t te r y

    M ic r o

    BAT 1.2 Hr

    S e l f t e s t r u n n in g

    6. Ver i fy a l l the modules/assembl ies passthe Sel f Test .

    I f the Sel f Test indicates a fa i lure,refer to 1-2-3, Table 1 for probablesources of fa i lure.

    I f the bat tery fa i ls, refer topara 1-2-1.6 to charge the bat tery.

    I f any other fa i lure occurs, refer theTest Set to a qual i f ied service

    technician for maintenance.

    TEST PROBABLE SOURCEOF FAILURE

    1 RAM Processor PCB Assy

    2 Flash

    3 CPLD

    4 NVRAM

    5 FPGA Mult i -Funct ion PCB Assy

    6 USB

    7 Keypad

    8 Battery Battery Pack

    9 Micro RF Assy

    10 Lock Detect

    11 Level Detect

    12 SWR

    13 Frequency Counter

    14 Local izer

    15 Marker

    16 Power Detector

    17 Antenna Protect ion

    Sel f Test Fai luresTable 1

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    31/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 1

    Mar 1/10

    4. OPERATING PROCEDURES

    4.1 GENERAL

    The IFR 4000 ver i f ies the operat ion andinstal lat ion of ILS, VOR and Marker Beacon

    receivers, VHF AM/FM, UHF AM and HFAM/SSB Transceivers and wi th the ELT Opt ion,121.5/243 and 406 MHz Emergency Beacons.

    This sect ion contains operat ing inst ruct ions forthe IFR 4000. Included is a descr ipt ion of theOperat ional Mode screens wi th F ie lddef in i t ions fo l lowed by general operat inginst ruct ions. For speci f ic Uni t Under Test(UUT) Procedures, refer to the UUT Manual .

    Refer to 1-2-2, F igure 2 for the locat ion of thecont ro ls, connectors and indicators.

    The IFR 4000 uses nine Main Operat ionalModes and one Opt ional Mode:

    SETUP Mode al lows the operator to setvar ious parameters used in test ing,conf igurat ion and memory storage. TheSetup Menu can be entered f rom any modeby pressing the SETUP Key.

    VOR Mode provides signal generat ion overthe VOR band (108.00 to 117.95 MHz) wi th30 Hz reference phase and 9960 Hz (subcarr ier f requency modulated wi th 30 Hzvar iable phase) ampl i tude modulated at30% per tone. VOR bear ing select ion is

    provided in preset steps of 30 or var iable

    steps of 0.1 .

    LOC (Local izer) Mode provides signalgenerat ion over the Local izer band of108.10 to 111.95 MHz, 90 and 150 Hz,ampl i tude modulated at 20% per tone.Var iable and f ixed DDM cont ro l is provided.

    G/S (Gl ideslope) Mode provides signalgenerat ion over the Gl ideslope band of329.15 to 335.00 MHz, 90 Hz and 150 Hz,ampl i tude modulated at 40% per tone.Var iable and f ixed DDM cont ro l is provided.

    MARKER BEACON Mode provides 75 MHzsignal generat ion, ampl i tude modulated at

    95% wi th selectable 400, 1300 and 3000Hz tones.

    ILS Mode provides simul taneous Local izer(wi th swept DDM), Gl ideslope and MarkerBeacon signals.

    COMM AM Mode provides signalgenerat ion over the Range of 10.00 to

    400.00 MHz in 1 kHz increments andmoni tor ing of t ransmit ter power andmodulat ion depth over the same range. Acal ibrated 1020 Hz tone, ampl i tudemodulated at 30%, is a lso provided.Frequency cont ro l is provided in 8.33 kHz / 25 kHz channel steps or in 1 kHz var iablesteps. Audio output is avai lable.

    COMM FM Mode provides signal generat ionover the Range of 10.00 to 400.00 MHz in1 kHz increments and moni tor ing oft ransmit ter power and modulat ion deviat ionover the same range. A 1000 Hz tone,f requency modulated at 5 kHz, is a lso

    provided. Frequency cont ro l is provided in12.5 kHz / 25 kHz channel steps or in1 kHz var iable steps. Audio output isavai lable.

    COMM SSB Mode provides signalgenerat ion and moni tor ing of t ransmit terpower and modulat ion depth over the rangeof 10.00 to 30.00 MHz. A 1000 Hz tone isalso provided. Audio output is avai lable.

    SWR Mode provides selected CWfrequency SWR measurement or sweptSWR measurement over a 10.00 to400.00 MHz range.

    SELCAL Mode provides selectableconsecut ive ampl i tude modulated tonepulse pai rs, which may be sentcont inuously or as a burst .

    FREQUENCY COUNTER Mode providesexternal f requency measurement over theRF I /O Connector and ANT Connector f rom10 to 400 MHz and over the AUX I /OConnector f rom 1 to 10 MHz.

    121.5/243 BCN Mode (p/o ELT Option)provides moni tor ing for 121.5/243 MHzswept tone short range Beacons anddisplays t ransmit ter f requency, power and

    start /stop tone f requencies. Audio outputis avai lable.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    32/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 2

    Mar 1/10

    4.1 GENERAL (cont)

    406 BEACON Mode (p/o ELT Option)provides moni tor ing for 406 MHzCOPAS/SARSAT Emergency LocatorTransmit ter (ELT), Emergency Posi t ionIndicat ing Radio Beacons (EPIRB and(Personal Locator) PLB Beacons. TheBeacon ut i l izes BPSK data to t ransmitposi t ion informat ion der ived f rom a longrange navigat ion system or GPS receiver.The Protocol management and data f ie lddecode is automat ical ly handled by theIFR 4000.

    4.2 SCREEN DESCRIPTIONS

    4.2.1 Startup Screen

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    33/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 3

    Mar 1/10

    4.2.2 Setup Menu

    BAT 1 .2 Hr

    PORT: FREQ: PRESET

    AP SWP RATE :20 sec VOR BRG:F IXED

    E X T A T T N : 0 .0 d B P WR D WN :1 0 min s

    IL S U N IT S :D D M RF L V L U N IT S :d B m

    K E Y C L IC K :O F F M O RS E C O D E : IF R

    A U D IO :O F F

    N E X TP A R A M

    G U I D E D

    T E S T

    S T O R E /R E C A L L

    S E T U P

    H / WT O O L S

    RF I /O

    I N F O

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    PORT

    This parameter selects which connector theTest Set generates and receives signals over:

    RF I /O selects the RF I /O Connector.

    ANT selects the ANT Connector.

    FREQ

    This parameter selects the type of generatorf requency select ion:

    PRESET provides f ixed selectablechannels for each Mode.

    CHANNEL al lows the select ion of any on-channel f requency wi th the Mode band.

    VAR al lows the select ion of f requency in1 kHz steps (100 Hz steps in SSB Mode),wi th in the Mode band.

    AP SWP RATE

    This parameter a l lows the Local izer DDM

    sweep rate to be set f rom 5 to 40 sec in 5 secincrements.

    VOR BRG

    This parameter selects the VOR Bear ing uni ts:

    FIXED al lows the select ion of bear ing in

    30 increments ( f rom 0) .VAR al lows the select ion of bear ing in

    0 .1 steps.

    EXT ATTN

    This parameter a l lows for compensat ion (0.0 to22.0 dB) of an External At tenuator on the RFI /O Connector. This faci l i ty is used forextending the power moni tor rat ing and range.

    I f the External At tenuator is selected, thevalue is d isplayed on al l Mode Screens in theEXT ATTN Field under the RF LVL Fie ld.

    PWR DWN

    This parameter sets the t ime (5 to 20 minutesor OFF) that the Test Set operates on thebat tery before powering the Test Set down.The t ime is ef fect ive f rom the last Key p ress.

    The PWR DWN t ime set is not appl icable whenthe Test Set is connected to an external powersource.

    ILS UNITS

    This parameter determines the Local izer andGl ideslope deviat ion uni ts: DDM (Di f ference in

    Depth of Modulat ion) or A (Microamps).

    RF LVL UNITS

    This parameter sets the RF Level uni ts to dBm

    or V (Vol ts into 50 ) .

    KEY CLICK

    This parameter turns the audible Key cl ick OFFor ON.

    MORSE CODE

    This parameter selects the Morse Code let ters(1 to 4) t ransmit ted in the VOR and ILSLocal izer Mode.

    AUDIO

    This parameter selects i f Audio Output isavai lable at the AUX I /O Connector in theCOMM AM, COMM FM, COMM SSB and121.5/243 BEACON Modes.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    34/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 4

    Mar 1/10

    4.2.2 Setup Menu (cont)

    SOFT KEYS

    The NEXT PARAM Sof t Key moves thecursor to the next F ie ld ( to the r ight ) on theSetup Menu.

    The GUIDED TEST Sof t Key displays theGuided Test Screen (para 1-2-4.2.3) .

    The STORE/RECALL Sof t Key displays theStore/Recal l Screen (para 1-2-4.2.4) .

    The H/W TOOLS Sof t Key displays theHardware Tools Screen (para 1-2-4.2.5) .

    The INFO Sof t Key displays the Info Screen(para 1-2-4.2.10).

    4.2.3 GUIDED TEST Screens

    The IFR 4000 provides a Guided Test funct ionwhich al lows inst rument setups to be stored inthe Test Set non-volat i le memory as asequence, under a user speci f ied name. Thesequence may be recal led and played

    backwards or forwards. This feature al lows aspeci f ic test schedule to be fo l lowed wi th theminimum of user intervent ion. 12 sequencesmay be stored, wi th a maximum of 50 steps persequence.

    4.2.3.1 GUIDED TEST Screen

    D E L E T E C R E A T E R U N R E T U R N

    1 B -7 4 7 -4 0 0

    5

    1 01 11 2

    G U ID E D T E S T BAT 1.2 Hr

    SOFT KEYS

    The DELETE Sof t Key displays thePassword Screen and, i f the Password is

    current ly entered, the Delete Store Screen.

    The CREATE Sof t Key displays thePassword Screen (para 1-2-4.2.3.2) and, i fPassword is correct ly entered, the StoreName Screen (para 1-2-4.2.3.3) .

    The RUN Sof t Key in i t ia tes the selectedtest .

    The RETURN Sof t Key displays the SetupMenu (para 1-2-4.2.2) .

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    35/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 5

    Mar 1/10

    4.2.3 GUIDED TEST Screens (cont)

    4.2.3.2 Password Screen

    1 2 3 4 5

    E n te r P a s s w o r d

    G U ID E D T E S T

    - - - -

    BA T 1.2 Hr

    SOFT KEYSThe 1 Sof t Key places a 1 on the Passwordl ine.

    The 2 Sof t Key places a 2 on the Passwordl ine.

    The 3 Sof t Key places a 3 on the Passwordl ine.

    The 4 Sof t Key places a 4 on the Passwordl ine.

    The 5 Sof t Key places a 5 on the Passwordl ine.

    4.2.3.3 Delete Store Screen

    Y E S N O

    Dele te ex is t ing s tore?

    DELETE STORE BAT 1.2 Hr

    SOFT KEYSThe YES Sof t Key deletes the storedsequence.

    The NO Sof t Key ignores the sequencedelet ion and displays the Guided TestScreen.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    36/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 6

    Mar 1/10

    4.2.3 GUIDED TEST Screens (cont)

    4.2.3.4 STORE NAME Screen

    S E L

    L I N E S E L E C T C A N CE L

    A B C D E F G H I J K L M N O P Q R S T U V W X Y Za b c d e f g h i j k l m n o p q r s t u v w x y z0 1 2 3 4 5 6 7 8 9 ! ( ) * , - . / : ; ? @ _

    P le a se e n te r s to r e n a me

    S T OR E N A M E

    BAT 1.2 Hr

    D E L E T E D ON E

    SOFT KEYSThe SEL LINE Sof t Key moves the cursordown one l ine. When the cursor is one thebot tom l ine, pressing the SEL LINE Sof tKey moves the cursor to the top l ine.

    The SELECT Sof t Key places the characterhighl ighted by the cursor on the name l ine.

    The DELETE Sof t Key deletes the r ight -most character on the name l ine.

    The CANCEL Sof t Key cancels the StoreName appl icat ion.

    The DONE Sof t Key stores the name on the

    l ine selected on the Store/Recal l Screen.

    4.2.4 STORE/RECALL Screens

    The Store/Recal l Screens al low the factorypreset conf igurat ion to be restored plus 11user-def inable conf igurat ions to be stored andrecal led. Appendix C contains the FactoryPresets for the 1. Preset Set t ings" select ion

    on the Store/Recal l Screen. A l l menu/screenf ie lds shown in Appendix C can be ut i l ized inthe creat ion of a user conf igurat ion select ion.

    4.2.4.1 STORE/RECALL Screen

    P R E V N E X T S T O R E R E C A L L R E T U R N

    1 P R E S ET SE T T IN G SIL S T R I -M O D E

    5

    1 01 11 2

    STORE/RE CALL BAT 1.2 Hr

    SOFT KEYS

    The PREV Sof t Key moves the cursor upone l ine.

    The NEXT Sof t Key moves the cursor downone l ine.

    The STORE Sof t Key displays the StoreName Screen (para 1-2-4.2.4.2) .

    The RECALL Sof t Key recal ls the set t ingsfor the l ine highl ighted by the cursor.

    The RETURN Sof t Key displays the SetupMenu (para 1-2-4.2.2) .

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    37/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 7

    Mar 1/10

    4.2.4 STORE/RECALL Screens (cont)

    4.2.4.2 STORE NAME Screen

    S E L

    L I N E S E L E C T C A N C E L

    A B C D E F G H I J K L M N O P Q R S T U V W X Y

    a b c d e f g h i j k l m n o p q r s t u v w x y z0 1 2 3 4 5 6 7 8 9 ! ( ) * , - . / : ; ? @ _

    P le a s e e n te r s to r e n a me

    S T OR E N A M E

    BA T 1.2 Hr

    D E L E T E D ON E

    SOFT KEYSThe SEL LINE Sof t Key moves the cursordown one l ine. When the cursor is one thebot tom l ine, pressing the SEL LINE Sof tKey moves the cursor to the top l ine.

    The SELECT Sof t Key places the characterhighl ighted by the cursor on the name l ine.

    The DELETE Sof t Key deletes the r ight -most character on the name l ine.

    The CANCEL Sof t Key cancels the StoreName appl icat ion.

    The DONE Sof t Key stores the name on the

    l ine selected on the Store/Recal l Screen.

    4.2.5 Hardware Tools Screen

    The Uni t Ser ia l Number and theMicroprocessor Version Number (only i f theELT Opt ion is insta l led) are displayed on theHardware Tools Screen.

    B A T 1 .2 H r

    RS232

    CA L

    H A R D WA R E T O OL S

    RETURNDIAGS

    S /N 9 9 9 9 9 9 9 9 9

    M IC R O V E R 1 .2M IC R O O P T 1

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    SOFT KEYS

    The RS-232 Sof t Key displays the RS-232Set t ings Screen (para 1-2-4.2.6) .

    The DIAGS Sof t Key displays theDiagnost ics Screen (para 1-2-4.2.7) .

    The CAL Sof t Key displays the Cal ibrat ionScreen (para 1-2-4.2.9) .

    The RETURN Sof t Key displays the SetupMenu (para 1-2-4.2.2) .

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    38/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 8

    Mar 1/10

    4.2.6 RS-232 Sett ings Screen

    BAT 1.2 Hr

    BAUD RATE: DATA BITS=8

    PARITY=NONE S T O P B IT S =1

    N E X T

    P A R A M

    R S -2 3 2 S E T T IN G S

    R E T U R N

    FLOW CONTROL:XON/XOFF

    1 1 5 2 0 0

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    BAUD RATE

    Using the INCREMENT/SELECT Data Key orthe DECREMENT/SELECT Data Key, set theBaud Rate to 9600, 19200, 38400, 57600 or115200.

    DATA BITS

    This f ie ld d isplayed a f ixed value (8) for the

    Data B i ts.

    PARITY

    This f ie ld d isplayed a f ixed value (NONE) forthe Par i ty.

    STOP BITS

    This f ie ld d isplayed a f ixed value (1) for theStop Bi ts.

    FLOW CONTROL

    Using the INCREMENT/SELECT Data Key orthe DECREMENT/SELECT Data Key, set theFlow Control to XON/XOFF, HARDWARE

    (RTS/CTS) or NONE.

    SOFT KEYS

    The NEXT PARAM Sof t Key moves thecursor to the next F ie ld ( to the r ight ) on theRS-232 Set t ings Screen.

    The RETURN Sof t Key displays theHardware Tools Screen (para 1-2-4.2.5) .

    4.2.7 Diagnostics Screen

    S E L FT E S T

    DIAGNOSTICS

    R E T U R N

    AMBIENT TEMPERATURE = 84 F 29 C

    RF BLO CK TEMPERATURE = 82 F 28 CBAT 1.2 Hr

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    AMBIENT TEMPERATURE

    This F ie ld d isplays the internal temperature ofthe Test Set .

    RF BLOCK TEMPERATURE

    This F ie ld d isplays the temperature of theinternal RF I /O At tenuator. An Overheat

    Screen appears i f the temperature of the RFI /O At tenuator reaches 71C.

    AU D I O

    O F F

    OVERHEAT

    ** * RF HARDWAR E TO O HOT * * *

    R e mo v e p o w e r f r o m in p ut to

    pr event damage to ins trument

    BAT 1.2 Hr

    The Overheat Screen is d isplayed unt i l the

    temperature of the RF I /O At tenuator is

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    39/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 9

    Mar 1/10

    4.2.7 Diagnostics Screen (cont)

    SOFT KEYS

    The SELF TEST Sof t Key displays the Sel fTest Screen (para 1-2-4.2.8) .

    The RETURN Sof t Key displays theHardware Tools Screen (para 1-2-4.2.5) .

    The AUDIO OFF Sof t Key (on the OverheatScreen) swi tches the Audio Warning OFF.

    4.2.8 Self Test Screen

    R U N

    S E L F T E S T

    R E T U R N

    - - - -- - - -

    - - - -- - - -- - - -- - - -- - - -- - - -

    - - - -

    Lock DetLv l Det

    S WRF r e q C t rL o c a l i z e rM a r k e rPwr Det

    A n t P r o t

    - - - -- - - -

    - - - -- - - -- - - -- - - -- - - -

    - - - -

    RA MFlash

    CPLDNVRAMF P G AUSBKeypadB a t te r y

    M ic r o

    BAT 1.2 Hr

    Dis c o n n e c t c a b le s f r o m p o r ts

    b efo r e r u nn in g s e l f t e s t

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    SOFT KEYS

    The RUN Sof t Key star ts the Sel f Test .

    The ABORT Sof t Key stops the Sel f Test .

    The RETURN Sof t Key displays theDiagnost ics Screen (para 1-2-4.2.7) .

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    40/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 10

    Mar 1/10

    4.2.9 Cal ibration Screen

    The Cal ibrat ion Screen is password protected.

    The Cal ibrat ion Screen is for Qual i f ied ServicePersonnel only.

    Enter Password

    1 3 4

    CALIBRATION

    52

    - - - -

    BAT 1.2 Hr

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    SOFT KEYS

    The 1 Sof t Key places a 1 on the Passwordl ine.

    The 2 Sof t Key places a 2 on the Passwordl ine.

    The 3 Sof t Key places a 3 on the Passwordl ine.

    The 4 Sof t Key places a 4 on the Passwordl ine.

    The 5 Sof t Key places a 5 on the Passwordl ine.

    4.2.10 Info Screen

    The Sof tware/F i rmware Version numbers andOpt ions avai lable are displayed on the InfoScreen.

    This s c re e n is a s a m ple o f the s c re e n tha t a ppe a rs .

    INFO

    R ETURN

    B A T 1.2 H r

    V E R S IO N 2.1 3

    B O OT S W V E R 1 .0 2F PG A F W V E R 1 .2CPLD FW VER 1 .0

    O P T IO N S

    E LT

    SOFT KEYS

    The RETURN Sof t Key displays the SetupMenu (para 1-2-4-2-2).

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    41/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 11

    Mar 1/10

    4.2.11 VOR Mode Screen

    FREQ:108 .000 MHz R F L VL : - 5 0 .0 d B m

    M M O D : C A L (6 0 %) M O D T O N E:O F FB R G : 0 .0 d e g T O /F R O M: T O30 Hz MOD: 30% 9960 Hz MOD:30%

    3 0

    M O D

    T O N E

    D E L B R G

    VO R

    TONE DEL:-

    T O /

    F R O M9 9 6 0M O D

    F I /O BAT 1 .2 Hr

    PORT

    This F ie ld, at the top of the screen, d isplaysthe Port (RF I /O or ANT) selected in the SetupMenu.

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging,--- is d isplayed in the BAT Field.

    FREQ

    This F ie ld cont ro ls the signal generatorf requency. Operat ion of th is F ie ld depends

    upon the set t ings of the FREQ Field in theSetup Menu.

    PRESET provides three f ixed selectablechannels for each Mode: 108.00 MHz,108.05 MHz and 117.95 MHz. Preset isused for quick conf idence test ing.

    CHANNEL al lows the select ion of any on-channel f requency wi th the Mode band.Channel is used for test ing of any 50 kHzspaced channel f rom 108.00 to117.95 MHz.

    VAR al lows the select ion of the f requencyf rom 107.00 to 118.00 MHz in 1 kHzincrements to perform receiver bandwidth

    and adjacent channel tests.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may beused to s lew the data. The SELECT DATAUNITS MSB Key or the SELECT DATAUNITS LSB Key may be used to select theFREQ uni ts to be slewed ( i .e. , 50 k Hz,100 kHz, etc. ) .

    RF LVL

    This F ie ld cont ro ls the signal generator RFoutput level . Operat ion of th is F ie ld dependsupon the set t ings of the RF LVL UNITS Field inthe Setup Menu.

    RF Level uni ts are displayed in dBm or V/mV.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may b e usedto slew the data. The SELECT DATA UNITSMSB Key or the SELECT DATA UNITS LSB Keymay be used to select the RF LVL uni ts to beslewed. The RF LVL is s lewed in 0.1, 1.0 or10 dB increments when the RF LVL Fie ld is set

    to e i ther dBm or V/mV.

    M MOD

    This F ie ld cont ro ls the signal generator MasterModulat ion Depth. The Master Modulat ion

    cont ro l funct ions as a mul t ip l ier of theindiv idual modulat ion components. The MasterModulat ion Depth is the sum of the Depths ofModulat ion (SDM) of the indiv idual tonecomponents. Using the INCREMENT/ SELECTData Key or the DECREMENT/ SELECT DataKey, modulat ion is set f rom 0% to 165% inincrement steps equal to the s um of theindiv idual tone components ( i .e. , i f two tonesof equal modulat ion depth are enabled, theM MOD Field increments in 2% steps). Thealgebraic sum of the indiv idual componentscan be >100%. For set t ings >100%, th isproduces a distor ted waveform. The accuracy

    in th is s i tuat ion is unspeci f ied. Press the MMOD Key to toggle the modulat ion set t ingbetween 0% and CAL (60%).

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    42/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 12

    Mar 1/10

    4.2.11 VOR Mode Screen (cont)

    MOD TONE

    This F ie ld cont ro ls the select ion of a 1020 HzStat ion Ident Tone or the Morse Code. Pressthe TONE Key to toggle the F ie ld between

    OFF, 1020 Hz or MORSE. The Morse Code isset in the Setup Menu.

    BRG

    This F ie ld cont ro ls the VOR Bear ing. Theoperat ion of th is F ie ld depends upon theset t ings of the VOR BRG Field in the SetupMenu.

    FIXED al lows the select ion of bear ing in

    30 steps ( f rom 0 ) .

    VAR al lows the select ion of bear ing in 0.1 steps.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may beused to s lew the data. The SELECT DATAUNITS MSB Key or the SELECT DATAUNITS LSB Key may be used to select the

    FREQ uni ts to be slewed ( i .e. , 0.1 , 1 ,etc. )

    TO/FROM

    This F ie ld cont ro ls the select ion of theTO/FROM funct ion:

    TO sets the Bear ing towards the VORBeacon.

    FROM sets the Bear ing away f rom the VORBeacon.

    Press the TO/FROM Sof t Key to togglebetween TO and FROM.

    30 Hz MOD

    This F ie ld cont ro ls the select ion of the 30 HzVar iable Phase modulat ion depth.

    Using the INCREMENT/SELECT Data Key orthe DECREMENT/SELECT Data Key,modulat ion is set f rom 0% to 30% in 1%increments.

    9960 Hz MOD

    This F ie ld cont ro ls the select ion of the 9960Hz sub-carr ier modulat ion depth.

    Using the INCREMENT/SELECT Data Key orthe DECREMENT/SELECT Data Key,modulat ion is set f rom 0% to 30% in 1%increments wi th MMOD in CAL Mode or f rom0% to 55% in 1% inc rements when MMOD isout of CAL.

    TONE DEL

    This F ie ld a l lows ei ther the 30 Hz Var iable,30 Hz Reference or both tones to be deleted.

    Press the TONE DEL Sof t Key to togglebetween OFF, REF, REF&VAR or VAR.

    SOFT KEYS

    The 30 MOD Sof t Key moves the cursor tothe 30 Hz MOD Field.

    The 9960 MOD Sof t Key moves the cursorto the 9960 Hz MOD Field.

    The TONE DEL Sof t Key moves the cursorto the TONE DEL Fie ld. Addi t ional keypresses are used to select between- (OFF), REF, REF&VAR and VAR.

    The BRG Sof t Key moves the cursor to the

    BRG Field. Each addi t ional key press adds30 to the F ie ld value.

    The TO/FROM Sof t Key moves the cursorto the TO/FROM Field. Each addi t ional keypress toggles the F ie ld between TO andFROM.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    43/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 13

    Mar 1/10

    4.2.12 LOCALIZER Mode Screen

    F R E Q:1 0 8 .1 0 0 MH z R F L V L : - 5 0 .0 d B m

    M M O D :C A L (4 0 %) M O D T O N E: O F F

    DEV STEP:F I XED 90 / 150Hz: 0 deg L O C D D M :

    0 .000 CENTER

    T O N E D E L : -

    D E V

    S T E P

    T O N E

    D E L

    L O C A L IZ E R

    9 0 /

    1 5 0 H z

    RF I /O BAT 1 .2 Hr

    PORT

    This F ie ld, at the top of the screen, d isplaysthe Port (RF I /O or ANT) selected in the SetupMenu.

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    FREQ

    This F ie ld cont ro ls the signal generatorf requency. Operat ion of th is F ie ld depends

    upon the set t ings of the FREQ Field in theSetup Menu.

    PRESET provides three f ixed selectablechannels for each Mode: 108.10 MHz,108.15 MHz and 110.15 MHz. Preset isused for quick conf idence test ing.

    CHANNEL al lows the select ion of any on-channel f requency wi th the Mode band.Channel is used for test ing of any 50 kHzspaced channel f rom 108.10 to111.95 MHz.

    VAR al lows the select ion of the f requencyf rom 107.00 to 113.00 MHz in 1 k Hzincrements to perform receiver bandwidthand adjacent channel tests.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may beused to s lew the data. The SELECT DATAUNITS MSB Key or the SELECT DATAUNITS LSB Key may be used to select theFREQ uni ts to be slewed ( i .e. , 50 kHz ,100 kHz, etc. ) .

    RF LVL

    This F ie ld cont ro ls the signal generator RFoutput level . Operat ion of th is F ie ld dependsupon the set t ings of the RF LVL UNITS Field in

    the Setup Menu.

    RF Level uni ts are displayed in dBm or V/mV.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may b e usedto slew the data. The SELECT DATA UNITSMSB Key or the SELECT DATA UNITS LSB Keymay be used to select the RF LVL uni ts to beslewed. The RF LVL is s lewed in 0.1, 1.0 or10 dB increments when the RF LVL Fie ld is set

    to e i ther dBm or V/mV.

    M MOD

    This F ie ld cont ro ls the signal generator Master

    Modulat ion Depth. The Master Modulat ioncont ro l funct ions as a mul t ip l ier of theindiv idual modulat ion components. The MasterModulat ion Depth is the sum of the Depths ofModulat ion (SDM) of the indiv idual tonecomponents. Using the INCREMENT/ SELECTData Key or the DECREMENT/ SELECT DataKey, modulat ion is set f rom 0% to 98% inincrement steps equal to the s um of theindiv idual tone components ( i .e. , i f two tonesof equal modulat ion depth are enabled, theM MOD Field increments in 2% steps). Pressthe M MOD Key to toggle the modulat ionset t ing between 0% and CAL (40%).

    MOD TONE

    This F ie ld cont ro ls the select ion of a 1020 HzStat ion Ident Tone or the Morse Code. Pressthe TONE Key to toggle the F ie ld betweenOFF, 1020 Hz or MORSE. The Morse Code isset in the Setup Menu.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    44/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 14

    Mar 1/10

    4.2.12 LOCALIZER Mode Screen (cont)

    DEV STEP

    This F ie ld cont ro ls the Deviat ion Step size.The operat ion of th is F ie ld depends upon theset t ings of the ILS UNITS Field in the Setup

    Menu. ILS UNITS may be set to DDM (DoubleDepth Modulat ion) or A (Microamps).

    DDM

    FIXED provides CENTER, LEFT and RIGHTdeviat ion select ions at 0.00, 0.093, 0.155and 0.200 DDM.

    VAR provides CENTER, LEFT and RIGHTdeviat ion select ions f rom 0 to 0.4 DDM in0.001 DDM steps. UNCAL is d isplayedwhen set to VAR and the LOC DDM Field isin a Non-Zero posi t ion o r when the M MODField is not set to CAL an d the LOC DDMField is in a Non-Zero posi t ion.

    A

    FIXED provides CENTER, LEFT and RIGHTdeviat ion select ions at 0, 90, 150 and

    194 A.

    VAR provides CENTER, LEFT and RIGHT

    deviat ion select ions f rom 0 to 388 A in

    1 A steps. UNCAL is d isplayed when setto VAR and the LOC DDM Field is in a Non-Zero posi t ion or when the M MOD Field isnot set to CAL and the LOC DDM Field is ina Non-Zero posi t ion.

    90/150 Hz

    This F ie ld cont ro ls the phase shi f t between the90 and 150 Hz tones.

    Use the 90/150Hz Sof t Key, INCREMENT/ SELECT DATA Key and DECREMENT/SELECT

    DATA Key to set the phase shi f t f rom 0 to

    120 in 5 steps.

    Press the 90/150Hz Sof t Key to toggle betweenno phase shi f t and the selected phase shi f t .

    This feature is used to s imulate the phase shi f tbetween the 90 and 150 Hz tones that occurs,when an ai rcraf t is turning to capture theLocal izer beam.

    TONE DEL

    This F ie ld a l lows ei ther the 90 Hz, 150 Hz orboth tones to be deleted. Press the TONE DELSof t Key to toggle between OFF, 90, 150 or90 & 150.

    This feature is used to ver i fy CDI (CourseDeviat ion Indicator) NAV f lag operat ion underinval id s ignal condi t ions.

    SOFT KEYS

    The DEV STEP Sof t Key moves the cursorto the DEV STEP Field. Each addi t ionalkey press toggles the F ie ld between FIXED

    and VAR.

    The TONE DEL Sof t Key moves the cursorto the TONE DEL Fie ld. Addi t ional keypresses are used to select between- (OFF), 90, 90 & 150 and 150.

    The 90/150 Hz Sof t Key moves the cursorto the 90/150 Hz Fie ld. Each addi t ionalkey press toggles the F ie ld between- (OFF) and 0 deg.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    45/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 15

    Mar 1/10

    4.2.13 GLIDESLOPE Mode Screen

    F R E Q:3 3 4 .7 0 0 MH z R F L V L : - 5 0 .0 d B mL O C F R E Q :1 0 8 .1 0 0 M H z M M O D :C A L (8 0 %)

    D E V S T E P : F IX E D 9 0 / 1 5 0 H z : -G/S DDM:

    0 .0 9 1 D O WN TONE DEL:-

    D E V

    S T E P

    T O N E

    D E L

    G L ID E S L O P E

    9 0 /

    1 5 0 H z

    RF I / O BAT 1.2 Hr

    PORT

    This F ie ld, at the top of the screen, d isplaysthe Port (RF I /O or ANT) selected in the SetupMenu.

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    FREQ

    This F ie ld cont ro ls the signal generatorf requency. Operat ion of th is F ie ld depends

    upon the set t ings of the FREQ Field in theSetup Menu.

    PRESET provides three f ixed selectablechannels for each Mode: 334.25 MHz,334.55 MHz and 334.70 MHz. Preset isused for quick conf idence test ing.

    CHANNEL al lows the select ion of any on-channel f requency wi th the Mode band.Channel is used for test ing of any 50 kHzspaced channel f rom 329.15 to335.00 MHz.

    VAR al lows the select ion of the f requencyf rom 327.00 to 337.00 MHz in 1 k Hzincrements to perform receiver bandwidthand adjacent channel tests.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may beused to s lew the data. The SELECT DATAUNITS MSB Key or the SELECT DATAUNITS LSB Key may be used to select theFREQ uni ts to be slewed ( i .e. , 50 kHz ,100 kHz, etc. ) .

    RF LVL

    This F ie ld cont ro ls the signal generator RFoutput level . Operat ion of th is F ie ld dependsupon the set t ings of the RF LVL UNITS Field in

    the Setup Menu.

    RF Level uni ts are displayed in dBm or V/mV.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may b e usedto slew the data. The SELECT DATA UNITSMSB Key or the SELECT DATA UNITS LSB Keymay be used to select the RF LVL uni ts to beslewed. The RF LVL is s lewed in 0.1, 1.0 or10 dB increments when the RF LVL Fie ld is set

    to e i ther dBm or V/mV.

    M MOD

    This F ie ld cont ro ls the signal generator Master

    Modulat ion Depth. The Master Modulat ioncont ro l funct ions as a mul t ip l ier of theindiv idual modulat ion components. The MasterModulat ion Depth is the sum of the Depths ofModulat ion (SDM) of the indiv idual tonecomponents. Using the INCREMENT/ SELECTData Key or the DECREMENT/ SELECT DataKey, modulat ion is set f rom 0% to 100% inincrement steps equal to the s um of theindiv idual tone components ( i .e. , i f two tonesof equal modulat ion depth are enabled, theM MOD Field increments in 2% steps). Pressthe M MOD Key to toggle the modulat ionset t ing between 0% and CAL (80%).

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    46/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 16

    Mar 1/10

    4.2.13 GLIDESLOPE Mode Screen (cont)

    DEV STEP

    This F ie ld cont ro ls the Deviat ion Step size.The operat ion of th is F ie ld depends upon theset t ings of the ILS UNITS Field in the Setup

    Menu. ILS UNITS may be set to DDM (DoubleDepth Modulat ion) or A (Microamps).

    DDM

    FIXED provides CENTER, LEFT and RIGHTdeviat ion select ions at 0.00, 0.091, 0.175and 0.400 DDM.

    VAR provides CENTER, LEFT and RIGHTdeviat ion select ions f rom 0 to 0.8 DDM in0.001 DDM steps. UNCAL is d isplayedwhen set to VAR and the LOC DDM Field isin a Non-Zero posi t ion o r when the M MODField is not set to CAL an d the LOC DDMField is in a Non-Zero posi t ion.

    A

    FIXED provides CENTER, LEFT and RIGHTdeviat ion select ions at 0, 78, 150 and

    343 A.

    VAR provides CENTER, LEFT and RIGHT

    deviat ion select ions f rom 0 to 686 A in

    1 A steps. UNCAL is d isplayed when setto VAR and the LOC DDM Field is in a Non-Zero posi t ion or when the M MOD Field isnot set to CAL and the LOC DDM Field is ina Non-Zero posi t ion.

    90/150 Hz

    This F ie ld cont ro ls the phase shi f t between the90 and 150 Hz tones.

    Use the 90/150Hz Sof t Key, INCREMENT/ SELECT DATA Key and DECREMENT/SELECT

    DATA Key to set the phase shi f t f rom 0 to

    120 in 5 steps.

    Press the 90/150Hz Sof t Key to toggle betweenno phase shi f t and the selected phase shi f t .

    TONE DEL

    This F ie ld a l lows ei ther the 90 Hz, 150 Hz orboth tones to be deleted. Press the TONE DEL

    Sof t Key to toggle between OFF, 90, 150 or90 & 150.

    This feature is used to ver i fy CDI (CourseDeviat ion Indicator) NAV f lag operat ion underinval id s ignal condi t ions.

    SOFT KEYS

    The DEV STEP Sof t Key moves the cursorto the DEV STEP Field. Each addi t ionalkey press toggles the F ie ld between FIXED

    and VAR.

    The TONE DEL Sof t Key moves the cursorto the TONE DEL Fie ld. Addi t ional keypresses are used to select between- (OFF), 90, 90 & 150 and 150.

    The 90/150 Hz Sof t Key moves the cursorto the 90/150 Hz Fie ld. Each addi t ionalkey press toggles the F ie ld between- (OFF) and 0 deg.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    47/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 17

    Mar 1/10

    4.2.14 MARKER BEACON Mode Screen

    FREQ: 75 .000 MHz RF LVL: - 50 .0 dBm

    M MOD: CAL ( 0%) MOD TONE: OFF

    MARKER BEACON RF I /O BAT 1 .2 Hr

    PORT

    This F ie ld, at the top of the screen, d isplaysthe Port (RF I /O or ANT) selected in the SetupMenu.

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    FREQ

    This F ie ld cont ro ls the signal generatorf requency. Operat ion of th is F ie ld depends

    upon the set t ings of the FREQ Field in theSetup Menu.

    PRESET provides three f ixed selectablechannels for each Mode: 74.50 MHz,75.00 MHz and 75.50 MHz. Preset is usedfor quick conf idence test ing.

    CHANNEL al lows the select ion of any on-channel f requency wi th the Mode band.Channel is used for test ing of any 25 kHzspaced channel f rom 72.00 to 78.00 MHz.

    VAR al lows the select ion of the f requencyf rom 72.00 MHz to 78.00 MHz in 1 kHzincrements to perform receiver bandwidthtests.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may beused to s lew the data. The SELECT DATAUNITS MSB Key or the SELECT DATAUNITS LSB Key may be used to select theFREQ uni ts to be slewed ( i .e. , 1 kHz,10 kHz, etc. ) .

    RF LVL

    This F ie ld cont ro ls the signal generator RFoutput level . Operat ion of th is F ie ld dependsupon the set t ings of the RF LVL UNITS Field in

    the Setup Menu.

    RF Level uni ts are displayed in dBm or V/mV.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may b e usedto slew the data. The SELECT DATA UNITSMSB Key or the SELECT DATA UNITS LSB Keymay be used to select the RF LVL uni ts to beslewed. The RF LVL is s lewed in 0.1, 1.0 or10 dB increments when the RF LVL Fie ld is set

    to e i ther dBm or V/mV.

    M MOD

    This F ie ld cont ro ls the signal generator Master

    Modulat ion Depth. Using the INCREMENT/ SELECT Data Key or the DECREMENT/ SELECT Data Key, modulat ion is set f rom 0%to 95% in 1% increments. Press the M MODKey to toggle the modulat ion set t ing between0% to CAL(95%) when MOD TONE is ON orbetween 0% to CAL(0%) when MOD TONE isOFF.

    MOD TONE

    This F ie ld cont ro ls the select ion of the Inner,Middle and Outer Marker Beacon Tones. Pressthe TONE Key to toggle between OFF, 400 Hz,1300 Hz and 3000 Hz.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    48/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 18

    Mar 1/10

    4.2.15 ILS Mode Screen

    FREQ: 108 .100 MHz RF LVL: - 50 .0 d BmG /S F R E Q : 3 3 4 .7 0 0 M H z

    M M O D :C A L (8 0 %) M O D T O N E: O F FAP SWP: OFF

    DEV STEP: F IXED 90 /150 Hz : 0 deg

    L O C D D M : G /S DD M :0 .0 0 0 C E N T E R 0 .0 0 0 C E N T E R

    T O N E D E L : -

    D E V

    S T E P

    A P

    S W P

    T O N E

    D E L

    I LS

    9 0 /

    1 5 0 H z

    RF I /O BAT 1 .2 Hr

    PORT

    This F ie ld, at the top of the screen, d isplaysthe Port (RF I /O or ANT) selected in the SetupMenu.

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    FREQ (Local izer)

    This F ie ld cont ro ls the signal generatorf requency. Operat ion of th is F ie ld depends

    upon the set t ings of the FREQ Field in theSetup Menu.

    The Local izer and Gl ideslope f requencyselect ions are pai red; a change to the FREQ(Local izer) select ion selects the pai red G/SFREQ.

    PRESET provides three f ixed selectablechannels for each Mode: 108.10 MHz,108.15 MHz and 110.95 MHz. Preset isused for quick conf idence test ing.

    CHANNEL al lows the select ion of any on-channel f requency wi th the Mode band.Channel is used for test ing of any 50 kHzspaced channel f rom 108.10 to117.95 MHz.

    VAR operates the same as CHANNEL dueto the pai r ing of Local izer and Gl ideslopef requencies.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may beused to s lew the data. The SELECT DATAUNITS MSB Key or the SELECT DATAUNITS LSB Key may be used to select the

    FREQ uni ts to be slewed ( i .e. , 50 k Hz,100 kHz, etc. ) .

    G/S FREQ

    This F ie ld cont ro ls the Gl ideslope signalgenerator f requency. Operat ion of th is F ie lddepends upon the set t ings of the FREQ Fieldin the Setup Menu.

    The Local izer and Gl ideslope f requencyselect ions are pai red; a change to the G/SFREQ select ion selects the pai red FREQ(Local izer) .

    PRESET provides three f ixed selectable

    channels for each Mode: 334.25 MHz,334.55 MHz and 334.70 MHz. Preset isused for quick conf idence test ing.

    CHANNEL al lows the select ion of any on-channel f requency wi th the Mode band.Channel is used for test ing of any 50 kHzspaced channel f rom 329.15 to335.00 MHz.

    VAR operates the same as CHANNEL dueto the pai r ing of Local izer and Gl ideslopef requencies.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may beused to s lew the data. The SELECT DATAUNITS MSB Key or the SELECT DATAUNITS LSB Key may be used to select theFREQ uni ts to be slewed ( i .e. , 50 k Hz,100 kHz, etc. ) .

    RF LVL

    This F ie ld cont ro ls the signal generator RFoutput level for the Gl ideslope signal .Operat ion of th is F ie ld depends upon theset t ings of the RF LVL UNITS Field in theSetup Menu.

    RF Level uni ts are displayed in dBm or V/mV.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may be usedto slew the data. The SELECT DATA UNITSMSB Key or the SELECT DATA UNITS LSB Keymay be used to select the RF LVL uni ts to beslewed ( i .e. , 0.1 dBm, 1 dBm, etc. ) .

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    49/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 19

    Mar 1/10

    4.2.15 ILS Mode Screen (cont)

    M MOD

    This F ie ld cont ro ls the signal generator MasterModulat ion Depth for the G/S Signal . TheMaster Modulat ion cont ro l funct ions as a

    mul t ip l ier of the indiv idual modulat ioncomponents. The Master Modulat ion Depth isthe sum of the Depths of Modulat ion (SDM) ofthe indiv idual tone components. Using theINCREMENT/ SELECT Data Key or theDECREMENT/ SELECT Data Key, modulat ionis set f rom 0% to 80% in increment steps equalto the sum of the indiv idual tone components( i .e. , i f two tones of equal modulat ion depthare enabled, the M MOD Field increments in2% steps). The sum of the depths ofmodulat ion for the Local izer S ignal is f ixed at40 plus any selected tones. Press the M MODKey to toggle the modulat ion set t ing between0% and CAL(80%).

    MOD TONE

    This F ie ld cont ro ls the select ion of a 1020 HzStat ion Ident Tone or the Inner, Middle andOuter Marker Beacon Tones.

    Press the TONE Key to toggle the F ie ldbetween OFF, 1020 Hz, MORSE, 400 Hz,1300 Hz and 3000 Hz.

    The 1020 Hz Stat ion Ident Tone is avai lableonly on the Local izer s ignal .

    A l l Tones are avai lable for the ANT Connector.Only 1020 Hz, MORSE and OFF are avai lable

    for the RF I /O Connector.The MORSE Code let ters are set in the SetupMenu.

    When any of the Marker Beacon tones (400 Hz,1300 Hz and 3000 Hz) are selected, MarkerOn is d isplayed under the MOD TONE Field.

    DEV STEP

    This F ie ld cont ro ls the Deviat ion Step size.The operat ion of th is F ie ld depends upon theset t ings of the ILS UNITS Field in the Setup

    Menu. ILS UNITS may be set to DDM (DoubleDepth Modulat ion) or A (Microamps).

    Local izer DDM

    FIXED provides CENTER, LEFT and RIGHTdeviat ion select ions at 0.00, 0.093, 0.155and 0.200 DDM.

    VAR provides CENTER, LEFT and RIGHTdeviat ion select ions f rom 0 to 0.4 DDM in0.001 DDM steps.

    Local izer A

    FIXED provides CENTER, LEFT and RIGHT

    deviat ion select ions at 0, 90, 150 and194 A.

    VAR provides CENTER, LEFT and RIGHT

    deviat ion select ions f rom 0 to 388 A in

    1 A steps. UNCAL is d isplayed when setto VAR and the LOC DDM Field is in a Non-Zero posi t ion or when the M MOD Field isnot set to CAL and the LOC DDM Field is ina Non-Zero posi t ion.

    Gl ideslope DDM

    FIXED provides CENTER, UP & DOWNdeviat ion select ions at 0.00, 0.091, 0.175and 0.400 DDM.

    VAR provides CENTER, UP & DOWNdeviat ion select ions f rom 0 to 0.8 DDM in0.001 DDM steps.

    NOTE: Local izer Deviat ion is

    automat ical ly set to A whenAutopi lot sweep is selected.

    Gl ideslope A

    FIXED provides CENTER, UP & DOWNdeviat ion select ions at 0, 78, 150 and

    343 A.

    VAR provides CENTER, UP & DOWN

    deviat ion select ions f rom 0 to 686 A in1 A steps. UNCAL is d isplayed when setto VAR and the LOC DDM Field is in a Non-Zero posi t ion or when the M MOD Field isnot set to CAL and the LOC DDM Field is ina Non-Zero posi t ion.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    50/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 20

    Mar 1/10

    4.2.15 ILS Mode Screen (cont)

    AP SWP

    This F ie ld cont ro ls the Local izer DDM sweep.

    Press the AP SWP Sof t Key to select OFF,START RIGHT or START LEFT.

    The Local izer deviat ion may be set f rom 0 to

    30 A using the LOC DDM LEFT Key and theLOC DDM RIGHT Key.

    90/150 Hz

    This F ie ld cont ro ls the phase shi f t between the90 and 150 Hz tones.

    Use the 90/150Hz Sof t Key, INCREMENT/ SELECT DATA Key and DECREMENT/SELECT

    DATA Key to set the phase shi f t f rom 0 to

    120 in 5 steps.

    Press the 90/150Hz Sof t Key to toggle between

    no phase shi f t and the selected phase shi f t .

    This feature is used to s imulate the phase shi f tbetween the 90 and 150 Hz tones that occurs,when an ai rcraf t is turning to capture theLocal izer beam.

    The phase shi f t is a lso appl ied to theGl ideslope 90 and 150 Hz tones.

    TONE DEL

    This F ie ld a l lows ei ther the 90 Hz, 150 Hz orboth tones to be deleted. Press the TONE DELSof t Key to toggle between OFF, 90, 150 or90 & 150.

    This feature is used to ver i fy CDI (CourseDeviat ion Indicator) NAV f lag operat ion underinval id s ignal condi t ions.

    SOFT KEYS

    The DEV STEP Sof t Key moves the cursorto the DEV STEP Field. Each addi t ionalkey press toggles the F ie ld between FIXEDand VAR.

    The AP SWP Sof t Key moves the cursor tothe AP SWP Field. Addi t ional key pressesare used to select between OFF, STARTRIGHT and START LEFT.

    The TONE DEL Sof t Key moves the cursorto the TONE DEL Fie ld. Addi t ional keypresses are used to select between- (OFF), 90, 90 & 150 and 150.

    The 90/150 Hz Sof t Key moves the cursorto the 90/150 Hz Fie ld. Each addi t ionalkey press toggles the F ie ld between- (OFF) and 0 deg.

  • 7/27/2019 Aeroflex 4000 NAVCOMM Test Set Operation Manual

    51/139

    OPERATION MANUALIFR 4000

    1-2-4Subject to Export Control , see Cover Page for detai ls . Page 21

    Mar 1/10

    4.2.16 COMM AM Mode Screen

    FREQ: 118 .0000 MHz RF LVL: - 50 .0 dBm

    M M O D : C A L (3 0 %) M O D T O N E : 1 0 2 0 H z

    RECEIVING

    -----------------------------------------------------------------------------------------T X F R E Q=- T X P WR =-

    T X M O D = -

    S W I T C HG E N / R X

    C O M M A M

    P O W E R M E T E R

    R F I /O

    P WR M T R : P E A K

    BAT 1 .2 Hr

    C H NL SP : 2 5 k H z

    C H N LS P Z E R O

    H O L DC L E A R

    H O LD T X

    PORT

    This F ie ld, at the top of the screen, d isplaysthe Port (RF I /O or ANT) selected in the SetupMenu.

    BAT

    This F ie ld d isplays the amount of run t imeavai lable before the bat tery requi res charging.

    When the Test Set is connected to an externalpower source and the bat tery is charging, --- is d isplayed in the BAT Field.

    FREQ

    This F ie ld cont ro ls the signal generatorf requency. Operat ion of th is F ie ld depends

    upon the set t ings of the FREQ Field in theSetup Menu.

    PRESET provides three f ixed selectablechannels for each band of operat ion:

    VHF

    118.00 MHz, 137.00 MHz and 156.00 MHz

    UHF

    225.00 MHz, 312.00 MHz and 400.00 MHz

    Preset is used for quick conf idence test ing.

    CHANNEL al lows the select ion of any on-

    channel f requency wi th the Mode band.Channel is used for test ing of any 8.33 kHzspaced channel f rom 118.00 to 156.00 MHzor any 25 kHz spaced channel f rom 10.00to 400.00 MHz.

    VAR al lows the select ion of the f requencyf rom 117.00 to 401.00 MHz in 1 k Hzincrements to perform receiver bandwidthtests.

    I f MOD STRIKE 2 on Mod St r ike Label ischecked and the uni t is loaded wi thVersion 2.06 Sof tware, VAR al lows theselect ion of the f requency f rom 10.00 to410.00 MHz in 1 kHz increments.

    The INCREMENT/SELECT Data Key or theDECREMENT/SELECT Data Key may beused to s lew the data. The SELECT DATAUNITS MSB Key or the SELECT DATAUNITS LSB Key may be used to select theFREQ uni ts to be slewed ( i .e. , 1 k Hz,10 kHz, etc. ) .

    RF LVL