8
www.aecinternet.com Pump Tanks Central chillers and pump tanks for processors in the plastics, food, chemical, pharmaceutical, printing, and machine tool industries Central Chillers PROVIDING SOLUTIONS, NOT JUST EQUIPMENT

AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

www.ae c i n t e rne t . c om

Pump Tanks

Central chillers and pump tanks for processors in the plastics, food,chemical, pharmaceutical, printing, and machine tool industries

Central Chillers

PROVIDING SOLUTIONS, NOT JUST EQUIPMENT

Page 2: AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

2Central Chillers

30RAP Series CentralChillers 32.6 to 169.1 kW

30RAP Series air�cooled centralchillers from AEC are designed forexterior installation, freeing upvaluable indoor equipment space.With hermetic scroll compressors,the 30RAP Series chillers provide32.6 to 169.1 kW coolingcapacities.

•Hermetic scroll compressors•Direct expansion type brazedplate evaporator(s)

•Aluminum microchannelcondenser with direct drivereinforced polymer fans

•Standard ambient operationfrom ��29ºC to 52ºC. Windbaffles required for �29ºCoperation

•R410a refrigerant•Safeties include: high and lowrefrigerant, freezestat, phaseloss, motor overload, and reverserotation of the compressor

AWX Winter�KoolerSupplemental ChillingSystem

AWX Series Winter�Kooler centralchillers are used where heatrecovery chilling systems are notrequired. They allow processcooling water to bypass yourchiller whenever ambient airtemperatures are low enough toprovide sufficient cooling withoutmechanical refrigeration.

•Fan cycling for varying loadand ambient conditions

•Weather resistant constructionincluding heavy gauge aluminumcabinet, weather protected fan

•Axial fans are the onlymoving parts

•Energy efficient fan motors:direct�drive fans rotate at950 rpm

•PVC�coated steel fan guards foroptimum corrosion protection

30RB Series CentralChillers 185.2 to 916.3 kW

30RB Series air�cooled centralchillers from AEC are designedfor exterior installation, freeing upvaluable indoor equipment space.With hermetic multiple scrollcompressors, the 30RB Serieschillers provide 185.2 to 916.3 kWcooling capacities.

•Direct expansion shell and tubecooler with cooler heaters

•Puron® R�410A refrigerant•Standard ambient operation from�29°C to 52°C

•Standard leaving watertemperature setpoints are from4°C to 29°C

•Optional non�fused disconnectswitch

•Optional remote display panel

Page 3: AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

3

AWX Series Supplemental Chilling System

30RB Series 185.2�916.3 kW Central Chiller

30RAP Series 32.6�169.1 kW Central Chiller

Central Chillers

ModelCooling capacity,

KW1Capacitystages

Chilled water flow,lpm

Height, mm Width, mm Depth, mm Ship. weight, kgs

30RAP010 32.6 13 84 1689 1029 1689 32030RAP015 43.8 13 114 1689 1029 1689 32530RAP020 55.3 22 144 1689 1029 2248 51430RAP025 67.2 22 175 1994 1029 2248 56430RAP030 84.7 22 220 1994 1029 2248 58230RAP035 100.8 44 262 1689 2350 2248 98230RAP040 115.5 44 300 1689 2350 2248 99230RAP045 128.1 44 334 1994 2350 2248 101630RAP050 141.0 44 369 1994 2350 2248 102730RAP055 156.8 44 407 1994 2350 2248 107630RAP060 169.1 44 441 1994 2350 2248 1078

1 Cooling capacity based upon 40% ethylene glycol at 10ºC LWT with 15.5ºC RWT at 35ºC ambient temperature

ModelCooling capacity,

kW1Capacitystages

Chilled water flow,lpm

Height, m Width, m Depth, m Ship. weight, kgs

30RB 060 185.2 4 585 2.28 2.24 2.39 175830RB 070 214.2 4 672 2.28 2.24 2.39 184930RB 080 247.8 5 779 2.28 2.24 2.39 196630RB 090 279.3 5 877 2.28 2.24 3.58 257130RB 100 308.4 5 969 2.28 2.24 3.58 267230RB 110 339.9 6 1068 2.28 2.24 2.24 278730RB 120 381.2 6 1197 2.28 2.24 4.77 331830RB 130 411.9 7 1296 2.28 2.24 4.77 345430RB 150 469.7 7 1478 2.28 2.24 4.77 388430RB 160 496.3 8 1566 2.28 2.24 5.96 438030RB 170 540.3 8 1699 2.28 2.24 5.96 453130RB 190 610.8 9 1923 2.28 2.24 7.16 517230RB 210 656.3 10 2067 2.28 2.24 7.16 590530RB 225 696.2 10 2193 2.28 2.24 7.16 605530RB 250 771.4 11 2428 2.28 2.24 8.4 669030RB 275 843.5 12 2660 2.28 2.24 9.5 734830RB 300 916.3 12 2884 2.27 2.24 10.7 7879

1 Cooling capacity based upon 50% ethylene glycol at 10ºC LWT with 15.5ºC RWT at 35ºC ambient temperature

Model Capacity, kW1 Flow, lpm2Fans Dimensions, mm Weight, kgs

kW qty. L W H Shipping Operating

AWX010 29.1 87 0.24 2 177 109 103 213 222AWX015 43.8 133 1.11 2 306 115.5 127 698.5 723AWX020 58.5 178 0.24 3 329.5 109 103 283.5 660AWX025 73.9 224 1.11 2 306 115.5 127 725.5 299AWX030 99.1 300 1.11 3 175.5 115.5 127 1016 1158.5AWX040 116.6 353 1.11 4 445.5 115.5 127 1125 1185.5AWX050 150.6 459 1.11 4 585.5 115.5 127 1447 1525.5AWX060 177.1 539 1.11 6 445.5 223.5 127 1079.5 1173.5AWX075 228.9 695 1.11 8 585.5 223.5 127 1428.5 1549.5

1 Based on 1 ton of refrigeration equal to 3,024 Kcal/hr2 Flows are based on cooling 1.07 lpm per 1,000 Kcal/hr of 50% water/50% ethylene glycolNote: Additional models are available, see our website for details

Page 4: AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

4

R Series Remote AirCooled Central Chillers

The R Series uses hermeticallysealed scroll compressors from 98to 315 kW, and semi�hermeticallysealed screw compressors from 91to 287 kW. All scroll compressorsand screw compressors up to192.5 kW are matched up withstainless steel brazed plateevaporators, and screw compressorsfrom 224 to 504 kW with shelland tube evaporators.

•High�efficiency scrollcompressors (87.5�287 kW) orscrew compressors (154�504 kW)

•HFC�410a refrigerant (scroll);HFC�134a refrigerant (screw)

•2 remote single circuitcondensers with 1.1 kW variablespeed lead fans and fan cycling

•Electronic expansion valves(screw chillers)

Pinnacle Series CentralChillers with Pump Tanks

The Pinnacle™ Series CentralChilling Stations includeindependent refrigerant circuits,which allow routine maintenancewithout costly downtime.Compressor staging providesenergy saving capacity control.

•Hermetically sealed scrollcompressors use 50% fewermoving parts than reciprocatingcompressors resulting inunparalleled efficiency,reliability and noise reduction

•100% non�ferrous stainless steeltank eliminates the need forroutine tank maintenance

•Optional dedicated standbypumps allow longer life (withautomatic motor cycling) andreduced downtime due to pumpmaintenance and repair

R Series Water CooledCentral ChillersThe R Series uses hermeticallysealed scroll compressors from 98to 315 kW, and semi�hermeticallysealed screw compressors from91 to 287 kW. All scrollcompressors are matched up withstainless steel brazed plateevaporators, and screwcompressors with shell and tubeevaporators.

•High�efficiency scrollcompressors (98�315 kW) orscrew compressors (91�287 kW)

•Stainless steel brazed plateevaporator (shell & tube on 147�287 kW screw compressor models)

•Cleanable shell and tubecondensers

•Two�way water regulating valve(scroll chillers)

•Electronic expansion valves(screw chillers)

•HFC�410a refrigerant (scroll);HFC�134a refrigerant (screw)

Central Chillers

Page 5: AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

5

RC Series Water Cooled Scroll ChillerRS Series Water Cooled Screw Chiller

Central Chillers

ModelNo. of

compressors

Coolingcapacity, kW(50º LWT)

Height,mm

Width,mm

Depth,mm

Ship.weight,lkgs

RCW 30 2 98.0 2159 1675 1143 689RCW 40 2 129.5 2159 2388 1143 862RCW 50 2 164.5 2159 2388 1143 962RCW 60 4 196.0 2159 2388 1143 1225RCW 80 4 252.0 1905 2388 1143 1497RCW 100 4 315.0 1905 2921 1143 1760

ModelNo. of

compressors

Coolingcapacity, kW(50º LWT)

Height,mm

Width,mm

Depth,mm

Ship.weight,kgs.

RSW 60 2 91.0 2159 2540 1143 1480RSW 75 2 122.5 2159 2540 1143 1593RSW 90 2 147.0 1880 2921 1829 1967RSW 100 4 189.0 1880 2921 1829 2260RSW 115 4 213.5 1955 3150 1829 2403RSW 145 4 234.5 2057 3480 1905 4011RSW 165 4 262.5 2057 3480 1905 4253RSW 195 4 287.0 2057 3480 1905 4345

RC Series Remote Air Cooled Scroll Chiller

ModelNo. of

compressors

Coolingcapacity, kW(50º LWT)

Capacitystages, qty.

Height, mm Width, mm Depth, mm Ship. weight, kgs

Chiller Cond. Chiller Cond. Chiller Cond. Chiller Cond.

RCR 30 2 87.5 2 2159 1270 1524 1155 1143 3226 608 331RCR 40 2 115.5 2 2159 1270 2108 1155 1143 3226 694 331RCR 50 2 147.0 2 2159 1270 2108 1155 1143 3226 785 331RCR 60 4 175.0 4 2159 1270 2108 1155 1143 3226 962 399RCR 80 4 231.0 4 71905 1270 2184 1155 1143 4572 1180 549RCR 100 4 287.0 4 1905 1270 2184 1155 1143 5918 1438 717

RS Series Remote Air Cooled Screw Chiller

ModelNo. of

compressors

Coolingcapacity, kW(50º LWT)

Capacitystages, qty.

Height, mm Width, mm Depth, mm Ship. weight, kgs.

Chiller Cond. Chiller Cond. Chiller Cond. Chiller Cond.

RSR 60 2 154.0

Infiniteunloading

1905 1270 2540 1155 1829 4725 1168 540RSR 75 2 192.5 1905 1270 2540 1155 1829 4572 1214 549RSR 90 2 224.0 1880 1270 2921 1155 1829 4572 1568 717RSR 100 2 269.5 1180 1270 2921 1155 1829 5918 1602 735RSR 115 2 301.0 1955 1270 3150 1155 1829 5918 1885 798RSR 145 2 381.5 2057 1270 3480 1155 1905 7265 3415 1080RSR 165 2 430.5 2057 1270 3480 1155 1905 7265 3426 1125RSR 195 2 504.0 2057 1270 3480 2235 1905 5918 3492 1465

Pinnacle Series Chiller

ModelNo. of

compressors

Coolingcapacity, kW(50º LWT)

Height,mm

Width,mm

Depth,mm

Ship.weight,kgs

RC 30 2 98.0 2159 1675 1143 689RC 40 2 129.5 2159 2388 1143 862RC 50 2 166.3 2159 2388 1143 962RC 60 4 196.0 2159 2388 1143 1225RC 80 4 252.0 1905 2388 1143 1497RC 100 4 315.0 1905 2921 1143 1760

Page 6: AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

6Pump Tanks

Cooling TowerPump Tank System

Pump tank assemblies featurestainless steel reservoirs and fullsized valving. Custom engineeredsystems are available with singleor double compartments andsingle or multiple pumpassemblies.

•Centrifugal pump(s) with castiron housings, bronze impellersand mechanical seals

•Standard pump trim to include afull sized suction valve, dischargecheck valve, throttling valve,pressure gauge and gauge trim

•Automatic make�up valve withsplash guard for trouble�freelevel control

•Overflow and valved drainconnections

•High efficiency pump motors

Polymer Pump Tanks

•Galvanized pump skid•Pumps mounted underneath tank•For C models, tanks comestandard with insulation

•Lug�mount butterfly valves•Automatic level controlmakeup valve

•White polyethylenetank construction

•Galvanized tank stand•Standard hardware includesthermometer(s), pump pressuregauge(s), drain valve

•Full�size pump trim for maximumefficiency; includes valvehandles, isolation, throttling,and check valves

•Standard sizes from 1893 to7949 liters in single and twintank designs are available

Chilled WaterPump Tank SystemSingle or double compartmentmodels may include up to sevenpumps per deck, or can even bedouble decked for the mostsophisticated applications. Ourfully engineered systems ofteninclude standby pumps, plusprovisions for future expansion.

•ODP motors and cast ironimpellers on standard pumps

•Stainless steel tank•Full�size pump trim for maximumefficiency; includes isolation,throttling, and check valves

•High efficiency motor from1.1 to 44.7 kW

•Corrosion�free, rotationalmolded polyethylene reservoir

Page 7: AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

7

Single Well Polymer Pump Tanks

Cooling Tower Pump Tanks

Chilled Water Pump Tanks

Pump Tanks

ModelCapacity, liters

Length, mm Width, mm Height, mm Ship. weight2, kgsOperating weight2,

kgsOverflow Operating

T150 (D) 511 378 1829 914 1016 273 817

PT400 (D) 1476 1325 2413 1422 1626 227 1588

T500 (D) 1817 1362 2591 1219 1321 908 2722

T700 (D) 2725 2044 2896 1829 1321 1180 3901

T1100 (D) 4069 3122 2896 1829 1956 1543 5625

T1600 (D) 6113 4693 3505 1829 1956 1815 7938

T2000 (D) 7721 5923 3810 2337 1981 2268 10025

T2700 (D) 10,219 7816 3810 3048 1981 2722 12928

T3700 (D) 13,872 10711 4115 3048 2286 3176 17056

T5100 (D) 19,417 14988 4115 4267 2337 3539 22998

2 Weights are for tank only; pump weight is not included

ModelCapacity, liters

Length, mm Width, mm Height, mm Ship. weight, kgsOperating weight,

kgsOverflow Operating

CT150 (D) 511 378 1829 914 1016 273 817

PC400 (D) 1476 1325 2413 1422 1626 227 1588

C500 (D) 1817 1362 2591 1219 1321 908 2722

C700 (D) 2725 2044 2896 1829 1321 1180 3901

C1100 (D) 4069 3122 2896 1829 1956 1543 5625

C1600 (D) 6113 4693 3505 1829 1956 1815 7938

C2000 (D) 7721 5923 3810 2337 1981 2268 10025

C2700 (D) 10,219 7816 3810 3048 1981 2722 12928

C3700 (D) 13,872 10711 4115 3048 2286 3176 17056

C5100 (D) 19,417 14988 4115 4267 2337 3539 22998

ModelCapacity, liters (max) Dimensions, mm Weight, kgs

Overflow Operate-T Operate-C Height Width Depth Shipping Operating

500 1893 1363 1590 3429 1270 1270 204 2093

1100 4164 3407 3748 2921 2286 2286 401 4559

1500 5867 5091 5602 3302 2286 2286 417 6305

2100 7949 6378 7003 3810 2286 2286 456 8392

Single Well Polymer Pump Tanks

ModelCapacity, liters (max) Dimensions, mm Weight, kgs

Overflow Operate-T Operate-C Height Width Depth Shipping Operating

500D 1893 1363 1590 3810 2794 1270 386 2272

1100D 4164 3407 3748 3429 5080 2286 408 4196

1500D 5678 5091 5602 3429 5080 2286 454 6124

2100D 8328 6378 7003 3429 5080 2286 531 9117

Page 8: AEC Family piecediflex.ru/assets/files/Catalogs/AEC Central Chill.pdf · 30rap025 67.2 22 175 1994 1029 2248 564 30rap030 84.7 22 220 1994 1029 2248 582 30rap035 100.8 44 262 1689

Multiple components provide maximum energy efficiencywith partial load capability.

Large central chiller and towersystems are designed for maximumefficiency for specific applications.

AEC systems are designed for efficient use ofspace but do not sacrifice accessibility formaintenance.

Rugged design is the core of AECdesign. Stainless Steel reservoirsservice with little maintenance.

Process Cooling Installations

AEC is committed to a continuing program of product improvement.Specifications, appearances and dimensions are subject to change without notice.

© 2011 AEC Bulletin AEC2-105EU Printed in USA

www.aec i n t e rne t . comaecw eb@corpema i l . c o m

BBFFDD!OOffxx! CCffss mm jj oo3:11!T/!271ui!TusffuOfx!Cfsmjo-!XJ!64262!!!Ufm;!!,2!373!752!9721!!Gby;!,2!373!752!9762

GGlloobbaallHHeeaaddqquuaarr ttee rr ss ::

BBFFDD!TTddiibbvvnnccvvss hh2211!F/!Xppegjfme!Se!$699Tdibvncvsh-!JM!71284!Ufm;!!,2!958!384!8911!!Gby;!,2!958!384!8915

BBFFDD!XXbbss ttbbxxvm/E{jblpxb!22613.345!Xbst{bxbUfm;!!,!59!33!4:1!:831Gby;!,!59!33!4:1!:835

BBFFDD! TTvv {{iippvv21:!Yjohqv!Spbe!TJQTv{ipv-!Dijob!326237Ufm;!!,97!623!9828!2:2:Gby;!,97!623!9828!2:27

BBFFDD! JJooeejjbbSfhvt-!Mfwfm!3-!Dpoobvhiu!QmbdfCvoe!Hbsefo!Spbe-!!Qvof!52211-!!Joejb!!!Ufm;!!,:2!31!5125!8686051258726Gby;!,:2!:4!8226!5156