12
Advanced Focusable Lighting

Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

Advanced Focusable Lighting

Page 2: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

1

Stellar provides advanced lighting performance with revolutionary highintensity, shadow-free and focusable optics, offering direct and precisesurgeon focus control for every procedure while retaining maximum intensityat any distance. After all, next to a surgeon’s eyes, what other surgical toolcould be more important?

Skytron Focusable Lighting Leadershipsince 1972

Design. Performance.

Page 3: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

Stellar’s high performanceand extremely durable polymer

Surgical Lightheads produce highintensity, soft white surgical lighting

when and where it is needed most, whileproviding effortless movement. Sealed lightheads

and smooth lines protect against dust accumulation,providing quick and easy cleanings betweensurgical cases.

2

BrighterSoft white, high intensity lighting @ 130,000 lux (ST23) or 160,000 lux (ST29) per lighthead.

Direct Focus ControlSurgeons can directly control focus and depth of field adjustment without having to move thelighthead, while retaining maximum intensity at any distance.

Non-Sterile Focus ControlA non-sterile focus control knob and four non-sterile positioning handles for the circulating nurseare standard.

Precise, Shadow Free OpticsAdvanced VSRD (Vertical Segmented Reflector Design) Optics provide precise, shadow-freeillumination and a uniform, adjustable 30” depth of field at any distance.

CoolRevolutionary coated reflectors reflect infrared heat to the rear of the lighthead, providing theoptimum balance between bright light and cool illumination.

Advanced lighting performance, surgeoncontrol, positioning & durability.

Page 4: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

3

STELLAR color correct optics

Multiple light sources, each equipped with theVSRD Optical System, provide an extendeddepth of field while retaining maximum intensityat any distance.

176 slices of light are produced from eachindividual light source, each combining to formcool, soft white and shadow-free illumination tothe surgical site.

HEATABSORBINGCOLORCORRECTIONFILTER

CHEMICALLYTREATEDREFLECTOR

DIFFUSERCOVER

OVERLAPPINGBEAMS OFLIGHT

CHEMICALLY TREATEDREFLECTOR

INFRARED HEATWAVES

HEATABSORBINGCOLORCORRECTIONFILTER

DIFFUSERCOVER

COOL COLORCORRECTEDLIGHT

Color Correct LightStellar VSRD optics provide the optimum color temperature of 4,000 K, ideally suited for providingbright, soft white light while reducing glare and eye fatigue. Stellar provides a color rendering index(CRI) of 93 for excellent tissue differentiation.

Page 5: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

STELLAR focusable optics

30”Depth

ofField

MaximumIntensityFocused

at 39”

Stellar Lightheadfocused at 30”.

Stellar Lightheadfocused at 60”.

Stellar Lighthead focused at 39” (1 meter)with a uniform 30” depth of field.

The Stellar Focusable Optics AdvantageMaximum Intensity at Any DistanceExtended working distances (beyond 1 meter)are not uncommon for many surgical procedures(Ob-Gyn, Orthopedics, Vascular and Urology).Stellar's advanced VSRD Optics optimally providesurgeons with sterile focus control. Just a ! turnof the sterile center focus handle capturesmaximum intensity at any distance without havingto physically reposition lightheads.

4

Deep Cavity IlluminationStellar Lighthead @ 60 in.(unfocused)

Deep Cavity IlluminationStellar Lighthead @ 60 in.(focused)

Page 6: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

STELLAR key features at a glance

Featherlight Maneuverability Features withIncreased Ranges of Movement

Surgeon SterileFocus Control

High Intensity,Shadow-Free Lighting

Cool, Color Correct Optics

5

20°

360°360°

360°

360°

90°

Page 7: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

Optional Camera ReadyLightheads with Removable

Handle Camera

Optional LED SkyLight Ambient Lightingfor Low Lighting Applications (MISSurgery)

Adaptable configurations provide the ability to upgrade forfuture clinical needs (flatscreen monitor arms and/or Skybooms).

6

Page 8: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

STELLAR reliability

Ongoing Reserve Bulb Protection! Bulb life is generally 5X competitive systems,

protected by Skytron’s Sof-Start System.

! Multi-light source design protects against surgicalinterruption during bulb failure.

Wall Controls! Compact and aesthetically

pleasing.

! Convenient to operate.

! Meets UL and CSA testingstandards.

Stellar Standard WallControl

Stellar Standard WallControl (with SkyLight PushButton Activation)

Bulb Change is quick and easilymade at users’ convenience

7

Stellar’s multi-light source design notonly protects against but preventssurgical light interruption duringbulb failure.

Page 9: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

8

STELLAR TVIIVideo Handle Camera (optional)

TVII Camera Controller

Stellar Lighting can be optionally equipped with a high quality,removable and transportable single chip handle camera, providingup to 10X Zoom. The TVII portable camera is compatible with anycamera ready ST29 (large) or ST23 (small) lightheads.

Page 10: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

9

STELLAR specifications

Technical DataStellar ST23 or ST29

Optical Characteristics ST23 ST29Diameter of Lighthead 23 in. (60cm) 29 in. (74cm)Intensity 130,000 lux (12,000 fc) 160,000 lux (15,000 fc)Diameter of Small Field 6 in. (152mm) 8 in. (203mm) 6 in. (152mm)Diameter of Large Field 8 in. (203mm) 10 in. (254mm) 8 in. (203mm)Depth of Volume of Light 30-60 in. (762-1524mm) 30-60 in.(762-1524mm)Color Rendering Index (Ra) 93 93Color Temperature 4000K 4000KInfrared Filtration Dichroic DichroicRadiant Energy less than 25,000 microwatts per cm2 less than 25,000 microwatts per cm2

Electrical CharacteristicsVoltage at Bulb 18.5-20VAC 18.5-20VACBulb Life up to 5,000 hrs. up to 5,000 hrs.Number of 24 V/ 50W Halogen Bulbs 5 per lighthead 7 per lightheadPower Consumption 250 watts (850 BTU/hr) 350 watts (1,190 BTU/hr)Amperage 2.5A, fuse protected 3.5A, fuse protectedCurrent Leakage less than 30 microamps less than 30 microampsVideo Camera Prewiring Optional Optional

Electrical ConnectionsInput Voltage to Power Supply 120VAC, 1 phase 120VAC, 1 phaseFrequency 60 Hz 60 HzOutput Voltage from Power Supply 0-20VAC adjustable 0-20VAC adjustable

Physical CharacteristicsVertical Travel 58 in. (1475mm) 71 in. (1805mm)

20° upward, 90° downward 20° upward, 90° downwardLighthead Rotation 360° 360°Pitch, Roll, Rotational Axis 360° 360°Weight of Fixture 119 lbs. (54kg) 139 lbs. (63kg)Moment Load 406 ft. lbs. 645 ft. lbs.

Arm LengthsSingle Arm 38 in. (965mm) 45.5 in. (1155mm)

LED SkyLight Optional Optional(Ambient Light for Low LightApplications)

Video Handle Camera Optional Optional

ST23 ST29

Page 11: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

10

STELLAR specifications

Technical DataStellar ST2323 or ST2923

Optical Characteristics ST2323 ST2923Diameter of Lighthead (2) 23 in. (60cm) 29 in. (74cm), 23 in. (60cm)Intensity 260,000 lux (24,000 fc) 290,000 lux (27,000 fc)Diameter of Small Field 6 in. (152mm) 8 in. (203mm) 6 in. (152mm)Diameter of Large Field 8 in. (203mm) 10 in. (254mm) 8 in. (203mm)Depth of Volume of Light 30-60 in. (762-1524mm) 30-60 in.(762-1524mm)Color Rendering Index (Ra) 93 93Color Temperature 4000K 4000KInfrared Filtration Dichroic DichroicRadiant Energy less than 25,000 microwatts per cm2 less than 25,000 microewatts per cm2

Electrical CharacteristicsVoltage at Bulb 18.5-20VAC 18.5-20VACBulb Life Up to 5,000 hrs. Up to 5,000 hrs.Number of 24 V/ 50W Halogen Bulbs 5 per lighthead 7 per lighthead, 5 per lightheadPower Consumption 500 watts (1,700 BTU/hr) 600 watts (2,040 BTU/hr)Amperage 5.0A, fuse protected 6.0A, fuse protectedCurrent Leakage less than 30 microamps less than 30 microampsVideo Camera Prewiring Optional Optional

Electrical ConnectionsInput Voltage to Power Supply 120VAC, 1 phase 120VAC, 1 phaseFrequency 60 Hz 60 HzOutput Voltage from Power Supply 0-20VAC adjustable 0-20VAC adjustable

Physical CharacteristicsVertical Travel 58 in. (1475mm) 71 in. (1805mm), 58 in. (1475mm)

20° upward, 90° downward 20° upward, 90° downwardLighthead Rotation 360° 360°Pitch, Roll, Rotational Axis 360° 360°Weight of Fixture) 210 lbs. (95kg) 230 lbs. (104kg)Moment Load 830 ft. lbs. 999 ft. lbs.

Arm LengthsUpper Arm 45.5 in. (1155mm) 45.5 in. (1155mm)Lower Arm 38 in. (965mm) 38 in. (965mm)

LED SkyLight Optional Optional(Ambient Light for Low LightApplications)

Video Handle Camera Optional Optional

ST2323 ST2923

Page 12: Advanced Focusable Lighting - Auxo Medicalauxomedical.com/.../2016/12/...Stellar-Brochure.pdf · The Stellar Focusable Optics Advantage Maximum Intensity at Any Distance Extended

5085 Corporate Exchange Blvd. SE • Grand Rapids, MI 495121-800-SKYTRON (759-8766) e-mail: [email protected]

Local Representative

2/2008

STELLAR specifications

ST232323 ST292323

Technical DataStellar ST232323 or ST292323

Optical Characteristics ST232323 ST292323Diameter of Lighthead (3) 23 in. (60cm) 29 in. (74cm), (2) 23 in. (60cm)Intensity 390,000 lux (36,000 fc) 420,000 lux (39,000 fc)Diameter of Small Field 6 in. (152mm) 8 in. (203mm) 6 in. (152mm)Diameter of Large Field 8 in. (203mm) 10 in. (254mm) 8 in. (203mm)Depth of Field 30 in. (762mm) 30 in. (762mm)Depth of Volume of Light 30-60 in. (762-1524mm) 30-60 in.(762-1524mm)Color Rendering Index (Ra) 93 93Color Temperature 4000K 4000KInfrared Filtration Dichroic DichroicRadiant Energy less than 25,000 microwatts per cm2 less than 25,000 microwatts per cm2

Electrical CharacteristicsVoltage at Bulb 18.5-20VAC 18.5-20VACBulb Life up to 5,000 hrs. up to 5,000 hrs.Number of 24 V/ 50W Halogen Bulbs 5 per lighthead 7 per lighthead, 5 per lightheadPower Consumption 750 Watts (3,550 BTU/hr) 850 Watts (2,890 BTU/hr)Amperage 7.5A, fuse protected 8.5A, fuse protectedCurrent Leakage less than 30 microamps less than 30 microampsVideo Camera Prewiring Optional Optional

Electrical ConnectionsInput Voltage to Power Supply 120VAC, 1 phase 120VAC, 1 phaseFrequency 60 Hz 60 HzOutput Voltage from Power Supply 0-20VAC adjustable 0-20VAC adjustable

Physical CharacteristicsVertical Travel 58 in. (1475mm) 71 in. (1805mm), 58 in. (1475mm)

20° upward, 90° downward 20° upward, 90° downwardLighthead Rotation 360° 360°Pitch, Roll, Rotational Axis 360° 360°Weight of Fixture 304 lbs. (138kg) 324 lbs. (147kg)Moment Load 1323 ft. lbs. 1491 ft. lbs.

Arm LengthsUpper Arm 53 in. (1350mm) 53 (1350mm)Middle Arm 45.5 in. (1155mm) 45.5 in. (1155mm)Lower Arm 38 in. (965mm) 38 in. (965mm)

LED SkyLight Optional Optional(Ambient Light for Low LightApplications)

Video Handle Camera Optional Optional