Page 1: Adixen by Alcatel Vacuum Technology

RO

UG

HI

NG

P

UM

PS

Rotary Vane PumpsPASCAL series

63

Adixen by Alcatel Vacuum Technology

ROU

GH

ING

PU

MPS

Page 2: Adixen by Alcatel Vacuum Technology

PASCAL series

A wide range of dedicated solutions

64

I series 2 stages 2002 I 2005 I 2010 I 2015 I 2021 I - - -

SD series 2 stages - 2005 SD 2010 SD 2015 SD 2021 SD 2033 SD 2063 SD 2100 SD

SD series 1 stage - 1005 SD - 1015 SD - - - -

C1 series 2 stages - 2005 C1 2010 C1 2015 C1 2021 C1 2033 C1 2063 C1 2100 C1

C2 series 2 stages - - 2010 C2 2015 C2 2021 C2 2033 C2 2063 C2 -

H1 series 2 stages - 2005 H1 - 2015 H1 - 2033 H1 2063 H1 -

2

1.4

5

3.8

10

6.8

15

10.6

21

14.6

30

24

60

43

100

85

Pumping m3/h

Speed cfm

H1 seriesHermetic series features a very high

C2 seriesSuitable for the most corrosiveapplications found

C1 seriesDesigned for high resistance

SD seriesStandard pumps for general purpose,

I seriesAddressing specific requirements

I SDC1

H1

Rotary Vane Pumps

Page 3: Adixen by Alcatel Vacuum Technology

PASCAL series

65

Selection guide according to applicationsPASCAL series rotary vane pumps can meet the requirements of your specificapplication by offering a wide range of dedicated series. This pump selection table will help you to choose the most suitable product for awide variety of vacuum processes in Industry, R&D, and Instrumentation equipment.

H1 SeriesC2 SeriesC1 SeriesISeriesSD Series

SeriesApplications

Gas analyzersLeak detectionMass spectrometersOther spectrometersElectron microscopesSurface analyzersCentrifugesSterilizationElectron tubesLampsTV tubes (CRT)RefrigerationAir conditioningDryingDistillationMetallurgyFreeze dryingCVD.LPCVDIon implantation Dry etchingLoad-lockCryogenicsGas recoveryOxygen pumping

● : recommanded ❍ : possible

NotesThe above chart indicates therecommended pump for generalgroups of applications. The choice may be different accor-ding to several parameters such as:working cycles, temperatures,corrosive gas concentrations...In addition, use of inlet or exhaustaccessories can improve the pump’sbehaviour and lifetime. See chapterAccessories, pages: 95 to 113.

For specific applications, not listedabove, or specific runningconditions, our applications

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 4: Adixen by Alcatel Vacuum Technology

PASCAL series

66

I series 2 stages2005I - 2010I

2015I - 2021I

Specially designed for analyticalInstrument applications:• Mass spectrometers• GC/MS• LC/MS• Electron microscopes• Residual Gas Analyzers• Sterilizers...

Optimized tightnessEfficient and reliable anti-suckback system is activated by the oil pump.For all static components attached tooil-casing or central housing, sealingis secured by O-rings. External shaft sealing arrangement can be renewed easily, without dismantling the pump,using the specific shaft seal kit.

Easy to useIn order to facilitate maintenanceactions or routine inspections, allcontrols and service access arelocated on the front of the oil-casing.

I series rotary vane pumps incorporateall the ALCATEL expertise in productdesign; they address all majorrequirements of the most sensitiveapplications of analytical instruments.

High performanceThe forced lubrication system, whichincludes a built-in oil vane pump,enables high performance fromatmosphere to the 10 -4 mbar range.Low backstreaming rate, pumping stability even for light gases are theresults of the advanced engineeringdesign of the I series pumps.

Low noise levelSpecific work on both the pump andthe motor design has reduced noise levels and irritating frequencies.Noise level of 49 dBA is typicalvalue for I series rotary vane pumps.

Universal single-phase motorIn order to meet one of the majorrequirements of international OEMs, I series pumps feature a uniquesingle-phase motor covering all world-wide electrical supplies. In addition,this motor complies with all majorelectrical standards: UL/CSA/CE.See page 18.

Compact designReduced dimensions, retractablehandle, combined with the choice ofhorizontal or vertical positionning ofinlet and exhaust ports* allow easyintegration in space-limited areas.

Easily accessible controls on the front of theoil casing

Flexible assembly of accessories Sleeve and leaktight lip seal, accessible foreasy maintenance.

Rotary Vane Pumps

(*) : optional horizontal ports, see page 89

Page 5: Adixen by Alcatel Vacuum Technology

PASCAL series

67

Nominal pumping speed (*)50Hz m3/h 5.4 9.7 15 20.7

60Hz cfm 3.8 6.8 10.6 14.6

Pneurop pumping speed (*)50Hz m3/h 4.8 8.5 12.5 16.5

60Hz cfm 3.4 6 8.8 11.8

Ultimate partial pressure (*) mbar 10-4 10-4 10-4 10-4

Ultimate total pressure (*)mbar 2.10-3 2.10-3 2.10-3 2.10-3

closed gas ballast

Ultimate total pressure (*)mbar 10-2m 10-2 10-2 10-2

open gas ballast

Water vapor capacity 50/60Hz g/h 120/110 125/100 110/100 90/90

Water vapor pressure 50/60Hz mbar 35/25 20/15 12/10 7/7

Noise level (**)50Hz dBA 48 49 50 50

60Hz dBA 50 51 52 53

Weight kg (lbs) 25 (55) 26 (57.2) 27 (59.4) 28 (61.6)

Dimensions see page 25 25 25 25

Electrical motors see page 8 8 8 8

Max nominal power rating 50/60Hz kW 0.45/0.55 0.45/0.55 0.45/0.55 0.45/0.55

Min ambient temperature °C (°F) 12 (54) 12 (54) 12 (54) 12 (54)

Max ambient temperature °C (°F) 45 (113) 45 (113) 45 (113) 45 (113)

Oil capacity l 0.83 0.95 0.95 0.98

Inlet flange ISO-KF DN 25 DN 25 DN 25 DN 25

Exhaust flange ISO-KF DN 25 DN 25 DN 25 DN 25

Specifications I series 2 stages

AccessoriesALCATEL offers a comprehensiverange of accessories (misteliminators, filters, traps...) in orderto optimize pump operation invarious running conditions.These accessories are describedpages 95 to 113.

Maintenance kitsIn order to simplify maintenanceperformed in the field, ALCATELprovides maintenance kits withinterchangeable components.

• Minor kit includes all necessaryseals (shaft seals, valves,o-rings...)

• Major kit includes Minor kitcomponents plus vanes, springs,plugs...

• Shaft seal kit includes allcomponents (lip seal, shaftsleeve...) necessary for fastperiodic renewal of externalshaft sealing.

Pumping speedcharacteristicsSee pages 79 to 83 for pumping speed/pressure andpressure drop curves.

Ordering information: see pages 88 to 91.

OilsOils of different viscosities and specifications are available, toenable customers to obtain the bestperformance from rotary vane pumpsunder different application conditons.See pages 92 and 93.

2021I2015I2010I2005IUnits

(*): according to Pneurop specifications; with ALCATEL mineral oil.

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 6: Adixen by Alcatel Vacuum Technology

PASCAL series

68

Easy to use, functional interface

Three-phase universal motor

Universal single-phase motor• voltage ranges:

High voltage: 180V to 254V 50/60 Hz

Low voltage: 90V to 132V 50/60Hz

• voltage range is determined by the position of a simple rocker switch,enabling the pump to be configured easily, without need for hard wiring.

• indication of voltage range is visible through a window provided in the box cover.

• on/off switch controls pump operation (optional)

• IEC socket allows flexibility for a wide choice of power lead terminations.

• complies with major international electrical standards: UL/CSA/CE

• protection level: IP43 (TEFC type)

Universal three-phase motor• voltage ranges:

High voltage: 342V to 460V 50Hz342V to 520V 60Hz

Low voltage: 170V to 254V 50Hz170V to 300V 60Hz

• complies with major international standards: UL/CSA/CE

• protection level: IP43 (TEFC type)• thermally protected: dry contact

(Normally Closed) is available

Unique universal motors• international usage• covering all worldwide voltages• complying with all electrical

standards• easy to configure• wide choice of plugs and cables• quiet operation

Universal single-phase and three-phase motors for all series from 5 to 21 m3/h

NotesThey are supplied with powercable and plugs for single-phasetypes; and without for three-phasetypes (except for US market:

Rotary Vane Pumps

Page 7: Adixen by Alcatel Vacuum Technology

PASCAL series

69

21.41.61.1

3.10-3

3.10-2

36/3530/30

5054

12 (26.4)2531

190/23012 (54)35 (95)0.35

DN 16Ø 10

m3/hcfm

m3/hcfm

mbar

mbar

g/hmbardBAdBA

kg (lbs)see pagesee page

W°C (°F)°C (°F)

lISO-KF

mm

I series 2002I

2002IUnits

Nominal pumping speed (*)50Hz60Hz

Pneurop pumping speed (*)50Hz60Hz

Ultimate total pressure (*)closed gas ballastUltimate total pressure (*)open gas ballastWater vapor capacity 50/60HzWater vapor pressure 50/60Hz

Noise level (**)50Hz60Hz

Weight (max)DimensionsElectrical motorsMax nominal power rating 50/60HzMin ambient temperatureMax ambient temperatureOil capacityInlet flangeExhaust port

(*): according to Pneurop specifications; with ALCATEL mineral oil.(**): typical values, according to Pneurop specifications.

Maintenance kits• minor kit includes all necessary

O-rings and seals.• major kit includes minor kit plus

AccessoriesALCATEL offers a full range ofconventional accessories in order tooptimize pump operation in variousrunning conditions.

OilsA wide choice of oils is available toobtain the best performance frompumps under different applicationconditions.

See pages 92 and 93.

Ordering information: see page 91 for more detailsconcerning different motor versions.

Specifications I series 2002I

Among the smallest pumps availableon the market, their innovativedesign allows to offer highperformances for small dimensionsand light weight.

2002I is specially designed for integration into portable or compactsystems (spectrometers, analyzers,leak detectors, centrifuges...).

Offering all advantages of new generation rotary vane pumps withsmall dimensions and weight, they include all necessary features forhigh performance :• forced lubrication• built-in anti-suckback• gas ballast valve ...

ImportantA121 is the recommended oil for2002 pumps in case of intensive

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 8: Adixen by Alcatel Vacuum Technology

PASCAL series

70

SD series 2 stages2005SD - 2010SD - 2015SD - 2021SD - 2033SD - 2063SD - 2100SD

From 5 to 21 m3/h:• no oil mist pollution at the exhaust :the natural lubrication design offersthe lowest oil mist level, even withhigh throughputs or frequent cyclingbetween atmosphere and ultimatepressure.• compact design : reduceddimensions, choice of horizontal orvertical inlet and exhaust ports*, allcontrols and service access locatedon the front.• optimized tightness : integrated anti-suckback ; all static sealings secured by O-rings; external shaft seal can be renewed easily, withoutdismantling the pump.• universal single-phase and

From 33 to 100 m3/h:• forced lubrication for continuous

operation at all pressures.• built-in anti-suckback, activated by

the oil pump, for protection ofvacuum system against pressure rise.

• rugged design for improved efficiency and reliability.

• universal and specific three-phasemotors, in line with international requirements (see orderinginformation pages 90 and 91).

From 5 to 100 m3/h :• high pumping speed from

atmosphere to vacuum.• efficient gas ballast for vapor

pumping.• air cooleed for optimum

performance• field serviceable, using the

2010SD

2100SD

2033SD

Adapted to all current non-corrosiveapplications :• Lamps manufacturing• Neon signs manufacturing• Electron tubes evacuation• TV tubes manufacturing• Metallurgy• Centrifuges....

SD series rotary vane pumps addressthe requirements of all major vacuumapplications in diverse industries.

Rotary Vane Pumps

(*) : optional horizontal ports, see page 89

Page 9: Adixen by Alcatel Vacuum Technology

PASCAL series

71

m3/hcfm

m3/hcfm

mbar

mbar

mbar

g/hmbar

kg (lbs)see pagesee page

kW°C (°F)°C (°F)

lISO-KFISO-KF

5.43.84.83.410-4

2.10-3

10-2

120/11035/2525 (55)

258

0.45/0.5512 (54)

45 (113)0.83

DN 25DN 25

9.76.88.56

10-4

2.10-3

10-2

125/10020/15

26 (57.2)258

0.45/0.5512 (54)45 (113)

0.95DN 25DN 25

1510.6128.810-4

2.10-3

10-2

110/10012/10

27 (59.4)258

0.45/0.5512 (54)45 (113)

0.95DN 25DN 25

20.714.615.511.810-4

2.10-3

10-2

90/907/7

28 (61.6)258

0.45/0.5512 (54)45 (113)

0.98DN 25DN 25

3023.327

18.82.10-4

3.10-3

2.10-2

70030

61 (134)2731

1.1/1.312 (54)45 (113)

3.6DN 40DN 40

6042.45538

3.10-4

3.10-3

2.10-2

120025

93 (205)2731

2.2/2.612 (54)45 (113)

7DN 40DN 40

Nominal pumping speed (*)50Hz60Hz

Pneurop pumping speed (*)50Hz60Hz

Ultimate partial pressure (*)Ultimate total pressure (*)closed gas ballastUltimate total pressure (*)open gas ballastWater vapor capacity 50/60HzWater vapor pressure 50/60HzWeight (max)DimensionsElectrical motorsMax nominal power rating 50/60HzMin ambient temperatureMax ambient temperatureOil capacityInlet flangeExhaust flange

Specifications SD series 2 stages

AccessoriesALCATEL offers a comprehensiverange of accessories (mist eliminators,filters, traps...) in order to optimizepump operation in various runningconditions. These accessories are described page 95 to 113.

Maintenance kitsIn order to simplify maintenance performed in the field, ALCATEL provides maintenance kits including interchangeable components.• Minor kit includes all necessary

seals (shaft seals, valves, o-rings...)• Major kit includes Minor kit plus

vanes, springs, plugs...• Shaft seal kit (for 2005SD to

2021SD) includes all components (lip seal, shaft sleeve...) necessary for fast periodic renewal ofexternal shaft seal.

Pumping speedcharacteristicsSee pages 79 to 83 for pumping speed/pressure andpressure drop curves.

Ordering information: see pages 88 to 91.

OilsOils of different viscosities and specifications are available, toenable customers to obtain the best performance from rotary vane pumps,under different application conditions.See pages 92 and 93.

2005SD 2010SD 2015SD 2021SD 2033SD 2063SD

1208510070.62.10-4

3.10-3

3.10-2

300040

231 (508)2931

3/3.612 (54)45 (113)

7.5DN 50DN 50

2100SDUnits

(*) : according to Pneurop specifications; with ALCATEL mineral oil.

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 10: Adixen by Alcatel Vacuum Technology

PASCAL series

72

Stainless steel, greycast iron, aluminium...

Viton seals

Chromium oxidecoating on bearing surfaces

High strenght oil sight glass

Integrated oil filter

Oil casing gas purge

external shafts

all shafts

C1 series 2 stages2005C1 - 2010C1 - 2015C1 - 2021C1 - 2033C1 - 2063C1 - 2100C1

Integrated anti-suckback activated bythe oil pump, providing vacuum integrity.

High performance : efficient pumping and low ultimatepressure, ensured by forcedlubrication from oil pump.

Efficient gas ballast, preventing vaporcondensation in the pump.

Easy to operate and to maintainField serviceable, using theappropriate maintenance kits.

Universal and specific motors :2005C1 to 2021C1 : single-phaseand three-phase, (see page 68).2033C1, 2063C1 : three-phase,(see ordering information pages 90and 91).

Design features for improved corrosion protection

2021C1

2063C1

2005C1 to2021C1

2033C1and 2063C1

2100C1Feature materials

Specially designed for pumping corrosive or aggressive gases in thechemical industry and R&D,meeting strict requirements withregards to material compatibility andcorrosion resistance.

C1 series rotary vane pumps areadapted to different applications involving corrosive media ; free ofsensitive materials, they offer reliableoperation even in aggressive conditions.

Rotary Vane Pumps

Page 11: Adixen by Alcatel Vacuum Technology

PASCAL series

73

Nominal pumping 50Hz speed (*)60HzPneurop pumping 50Hzspeed (*) 60HzUltimate partial pressure (*)Ultimate total pressure (*)closed gas ballastUltimate total pressure (*)open gas ballastWater vaporcapacity 50/60HzWater vaporpressure 50/60HzWeight (max)DimensionsElectrical motorsMax nominal powerrating 50/60HzMin ambient temperatureMax ambient temperatureOil capacityInlet flangeExhaust flange

Specifications C1 series 2 stages

AccessoriesA comprehensive range of accessoriesis available, in order to optimizepump operation in various runningconditions. These accessories aredescribed pages 95 to 113.

Maintenance kitsIn order to simplify maintenanceperformed in the field, ALCATELprovides maintenance kits includinginterchangeable components.• Minor kit includes all necessary

seals (shaft seals, valves, o-rings...)• Major kit includes Minor kit plus

vanes, springs, plugs...• Shaft seal kit (for 2005C1 to

2021C1) includes all components (lip seal, shaft sleeve...) necessaryfor fast periodic maintenance.

Pumping speedcharacteristicsSee pages 79 to 83 for pumpingspeed/pressure and pressure drop

OilsOils of different viscosities andchemical compatibility are available,to enable customers to obtain the bestperformance from rotary vanepumps. See pages 92 and 93.

2005C1 2010C1 2015C1 2021C1 2033C1 2063C1 2100C1Units

m3/hcfm

m3/hcfm

mbar

mbar

mbar

g/h

mbar

kg (lbs)see pagesee page

kW

°C (°F)°C (°F)

lISO-KFISO-KF

5.43.84.83.410-4

2.10-3

10-2

120/110

35/25

25 (55)258

0.45/0.55

12 (54)45 (113)

0.83DN 25DN 25

9.76.88.56

10-4

2.10-3

10-2

125/100

20/15

26 (57.2)258

0.45/0.55

12 (54)45 (113)

0.95DN 25DN 25

1510.612.58.810-4

2.10-3

10-2

110/100

12/10

27 (59.4)258

0.45/0.55

12 (54)45 (113)

0.95DN 25DN 25

20.714.616.511.810-4

2.10-3

10-2

90/90

7/7

28 (61.6)258

0.45/0.55

12 (54)45 (113)

0.98DN 25DN 25

3023.327

18.83.10-4

3.10-3

2.10-2

700

30

74 (163)2731

1.1/1.3

12 (54)45 (113)

3.6DN 40DN 40

6042.45538

3.10-4

3.10-3

2.10-2

1200

25

98 (216)2731

2.2/2.6

12 (54)45 (113)

7DN 40DN 40

1208510070.63.10-4

3.10-3

2.10-1

3000

40

231 (508)2931

3/3.6

12 (54)45 (113)

7.5DN 50DN 50

(*) : according to Pneurop specifications ; with ALCATEL mineral oil.

ImportantIndustries and R&D are using awide range of different chemicals;C1series rotary vane pumps can beused with many of these products. As far as material compatibility isconcerned, we advise our custo-mers to contact our applicationsspecialists, in order to define themost appropriate solution.

Ordering information: see pages 88 to 91.

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 12: Adixen by Alcatel Vacuum Technology

PASCAL series

74

all shafts

all shafts

Viton seals

Chromium oxide coatingon bearing surfaces

Synthetic oil sight material

Oil casing purge

Gas ballast connection forneutral gas purge

Oil degassing system : bubbler

Composite solid vane material(HP stage, oil pump)

Oil pump pressure sensor connection

Oil temperature sensor connection

C2 series 2 stages 2010C2 - 2015C2 - 2021C2 - 2033C2 - 2063C2

Built-in anti-suckback for vacuum integrity.

Forced lubrication for reliable Sensor connections for pump operation monitoring, availableon models 2033C2 and 2063C2.

Designed and prepared for PFPEfluids fluids must be orderedseparately ; see pages 92 and 93.

Bubbler purge: providing continuousnitrogen injection into the oil, resulting in a 10° C lower operatingtemperature and reduced corrosion

Specific design features

2010C2 to 2021C2 2033C2 and 2063C2Features

Sensors connections on 2033C2

Oil degassing system : bubbler on 2021C2

2021C2

Adapted to harsh processesin the semiconductor manufacturingindustry :• Plasma etching• Reactive sputtering• Ion implantation• PECVD• RIE....

C2 series rotary vane pumps are the best answer to the most aggressivepumping environments. They incorporate specific anti corrosion features forimproved reliable operation.

Rotary Vane Pumps

Page 13: Adixen by Alcatel Vacuum Technology

PASCAL series

75

Specifications C2 series 2 stages

AccessoriesA comprehensive range of accessoriesis available, in order to optimizepump operation in various runningconditions. These accessories aredescribed pages 95 to 113.

Maintenance kitsIn order to simplify maintenanceperformed in the field, ALCATELprovides maintenance kits includinginterchangeable components:• Minor kit includes all necessary

seals (shaft seals, valves, o-rings...)• Major kit includes Minor kit plus

vanes, springs, plugs...• Shaft seal kit (for 2010C2, 2015C2

and 2021C2 ) includes allcomponents (lip seal, shaft sleeve...)necessary for fast periodicmaintenance.

OilsSynthetic oils of different viscositiesand chemical compatibility areavailable, to enable customers toobtain the best performance fromrotary vane pumps. Recommendedoil is A113. See pages 92 and 93.

2010C2 2015C2 2021C2 2033C2 2063C2Units

(*) : according to Pneurop specifications; with ALCATEL 113 synthetic fluid.

6042.45538

5.10-4

3.10-3

98 (216)2831

2.2/2.612 (54)45 (113)

7DN 40DN 40

3023.327

18.85.10-4

3.10-3

76 (167)2831

1.1/1.312 (54)45 (113)

3.6DN 40DN 40

20.714.616.511.85.10-4

3.10-3

28 (61.6)268

0.45/0.5512 (54)45 (113)

0.98DN 25DN 25

1510.612.58.8

5.10-4

3.10-3

27 (59.4)268

0.45/0.5512 (54)45 (113)

0.95DN 25DN 25

9.76.88.56

5.10-4

3.10-3

26 (57.2)268

0.45/0.5512 (54)45 (113)

0.95DN 25DN 25

m3/hcfm

m3/hcfm

mbar

mbar

kg (lbs)see pagesee page

kW°C (°F)°C (°F)

lISO-KFISO-KF

Nominal pumping speed (*)50Hz60Hz

Pneurop pumping speed (*)50Hz60Hz

Ultimate partial pressure (*)Ultimate total pressure (*)closed gas ballastWeight (max)DimensionsElectrical motorsMax nominal power rating 50/60HzMin ambient temperatureMax ambient temperatureOil capacityInlet flangeExhaust flange

Pumping speedcharacteristicsSee pages 79 to 83 for pumpingspeed/pressure and pressure drop

Important

Semiconductor manufacturingindustry uses a wide range ofdifferent corrosive gases. As far as material and fluid compa-tibility are concerned, as well as forparticles or solids generation in thepumps, we advise our customers tocontact our applications specialists in order to define the mostappropriate solution.

Ordering information: see pages 88 to 91.

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 14: Adixen by Alcatel Vacuum Technology

PASCAL series

76

60

60

60

60

60

60

1000

200

20

1000

1000

100

50

1000

2000

H1 series 2 stages 2005H1 - 2015H1 - 2033H1 - 2063H1

Specific design features for improved tightness• static : oil casing is made of weldedstainless steel; all seals are securedwith O-rings. Central housing ismachined from a solid piece ofaluminum.• dynamic : shaft sealingarrangement design includes anadditional oil sealed compartmentbetween lip seals.

Forced lubrication for reliable operation at all pressures.

Built-in anti suckback for vacuum integrity.

Efficient cooling :2005/2015 H1 : air2033/2063 H1 : water

Operating pressuresH1 series rotary vane pumps canoperate with exhaust pressure from 50to 2000 mbar (absolute pressure).For 2033H1 and 2063H1, the direction of the external lip seal isdifferent, whether the exhaust pressureis above or below atmosphere ; part numbers are different: consultAlcatel before ordering.

Power limitation/operating pressures

H1 series rotary vane pumps arespecially designed for pumpinghelium 3 and other precious or exoticgases used in closed-loop cryogenic systems.These hermetic pumps feature specifictechnological design, allowing highlevel of tightness for pumped gasesand ambient atmosphere.Each pump is individually tested and delivered with a tightness control certificate.

Max inlet pressure ¥ continuous operation mbarExhaust pressure

2005H1mbar 2015H1 2033H1 2063H1

Tightness design of shaft sealing

4

532

1

6

1/ rotor - 2/ flange - 3/housing 4/ oil sealed compartment (oil) 5/ fill - 6/ drain

Specially designed for pumping andhandling precious gases, while preserving a high level of tightness.

Rotary Vane Pumps

Page 15: Adixen by Alcatel Vacuum Technology

PASCAL series

77

Specifications H1 series 2 stages

AccessoriesALCATEL offers a comprehensiverange of accessories (mist eliminators,filters, traps...) in order to optimizepump operation in various runningconditions. These accessories aredescribed page 95 to page 113.

Maintenance kitsIn order to simplify maintenance performed in the field, ALCATEL provides maintenance kits includinginterchangeable components:• Minor kit includes all necessary

seals (shaft seals, valves, o-rings...)• Major kit includes Minor kit plus

vanes, springs, plugs....

Pumping speedcharacteristicsSee pages 79 to 83 for pumpingspeed/pressure and pressure dropcurves.

Ordering information: see pages 88 to 91.

OilsOils of different viscosities and specifications are available, toenable customers to obtain the best performance from rotary vanepumps, under different applicationconditions. See pages 92 and 93.

2063H12033H12015H12005H1Units

(*): according to Pneurop specifications; with ALCATEL mineral oil.

6042.45538

3.10-4

3.10-3

5020002.10-7

32831

100 (220)2.2/2.612 (54)45 (113)

7.8DN 40DN 40

3023.327

18.82.10-4

3.10-3

5020002.10-7

22831

74 (163)1.1/1.312 (54)45 (113)

4.8DN 40DN 40

1510.612.58.810-4

2.10-3

5020002.10-7

-

268

29.5 (65)0.45/0.5512 (54)35 (95)0.78

DN 25DN 25

5.43.84.83.410-4

2.10-3

5020002.10-7

-268

27 (59.5)0.45/0.55

12 (54)35 (95)0.58

DN 25DN 25

m3/hcfm

m3/hcfm

mbarmbarmbarmbar

mbar.l/sl/mn

see pagesee pagekg (lbs)

kW°C (°F)°C (°F)

lISO-KFISO-KF

Nominal pumping speed (*)50Hz60Hz

Pneurop pumping speed (*)50Hz60Hz

Ultimate partial pressure (*)Ultimate total pressure (*)Min exhaust pressureMax exhaust pressureTightness : leak rateWater cooling flow (20°C)DimensionsElectrical motorsWeight (max)Max nominal power rating 50/60HzMin ambient temperatureMax ambient temperatureOil capacityInlet flangeExhaust flange

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 16: Adixen by Alcatel Vacuum Technology

PASCAL series

78

SD series 1 stage 1005SD - 1015SD

AccessoriesA comprehensive range of accessoriesis described pages 95 to 113.

Maintenance kitsALCATEL provides maintenance kitsincluding interchangeablecomponents:• Minor kit includes all necessary seals • Major kit includes Minor kit plus

vanes, springs, plugs...

Pumping speedcharacteristics

See pages 79 to 83 for pumpingspeed/pressure and pressure dropcurves.

Ordering information: see pages 88 to 91.

OilsOils of different viscosities and specifications are available; see pages 92 and 93.

Specifications1005SD 1015SDUnits

(*): according to Pneurop specifications; with ALCATEL mineral oil.

Single stage rotary vane pumps arethe best choice whenever highcondensable vapor pumpingcapacity is needed or low ultimatepressure is not necessary.They are of the same design as thecorresponding 2 stages models(except 1015, using forcedlubrication).

m3/hcfm

m3/hcfm

mbar

mbar

g/hmbar

kg (lbs)see pagesee page

kW°C (°F)°C (°F)

lISO-KFISO-KF

5.43.84.83.4

5.10-2

4

120/13035/25

21 (46.2)258

0.45/0.5512 (54)45 (113)

1.1DN 25DN 25

1510.612.58.8

5.10-2

7

330/37035/30

24.5 (54)258

0.45/0.5512 (54)45 (113)

1DN 25DN 25

Nominal pumping speed (*)50Hz60Hz

Pneurop pumping speed (*)50Hz60Hz

Ultimate total pressure (*)closed gas ballastUltimate total pressure (*)open gas ballastWater vapor capacity 50/60HzWater vapor pressure 50/60HzWeight (max)DimensionsElectrical motorsMax nominal power rating 50/60HzMin ambient temperatureMax ambient temperatureOil capacityInlet flangeExhaust flange

Rotary Vane Pumps

Page 17: Adixen by Alcatel Vacuum Technology

PASCAL series

79

10

5

10

15

20

-3 10-2 10 -1 100 101 102 103

[m3/h] pumping speed

total inlet pressure [mbar]

2021

2015

2010

2005

10

5

10

15

20

-3 10-2 10 -1 100 101 102 103

[m3/h] pumping speed

total inlet pressure [mbar]

2015

2005

10

5

10

15

20

-3 10-2 10 -1 100 101 102 103

[m3/h] pumping speed

total inlet pressure [mbar]

1005

1015

2005I/C1 - 2010I/C1/C22015I/C1/C2 - 2021I/C1/C2

2005SD - 2010SD 2015SD - 2021SD

2005H1 - 2015H1

1005SD - 1015SD2033SD/C1/C2/H12063SD/C1/C2/H1

Pumping curves 50 Hz

10

5

10

15

20

-3 10 -2 10 -1 100 10 1 10 2 10 3

[m3/h] pumping speed

total inlet pressure [mbar]

2021

2015

2010

2005

10

0,5

1

1,5

2

-3 10-2 10 -1 100 101 102 103

[m3/h] pumping speed

total inlet pressure [mbar]

2002

2002I

10

20

10

40

30

60

50

80

70

-3 10-2 10 -1 10 0 10 1 10 2 10 3

[m3/h] pumping speed

total inlet pressure [mbar]

2033

2063

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 18: Adixen by Alcatel Vacuum Technology

PASCAL series

80

200 40 60 80 100 120 140 160 180 20010-3

10-2

10 -1

100

101

102

103 [mbar] inlet pressure drop

time [mn]

V = 1m3

2005

2010

2021

2015

10 20 30 40 5010-3

10-2

10 -1

100

101

102

103 [mbar] inlet pressure drop

time [mn]

V = 1m3

2033

2063

2100SD/C1

2005SD/I/C1/H1 - 2010SD/I/C1/C22015SD/I/C1/C2/H1

2021SD/I/C1/C2

2033SD/C1/C2/H12063SD/C1/C2/H1

Pumping curves 50 Hz

10

40

20

80

60

120

100

160

140

-3 10 -2 10 -1 100 10 1 10 2 10 3

[m3/h] pumping speed

total inlet pressure [mbar]

2100

Rotary Vane Pumps

Page 19: Adixen by Alcatel Vacuum Technology

PASCAL series

81

Pumping curves 50 Hz - 60 Hz

0 60 120 180 240 300 36010

-3

10-2

10 -1

100

101

102

103

[mbar] inlet pressure drop

time [mn]

V = 0.5 m3

60Hz

50Hz

5 10 15 20 2510

-3

10-2

10 -1

100

101

102

103 [mbar] inlet pressure drop

time [mn]

V = 1m3

50Hz

60Hz

2002I 2100SD/C1

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 20: Adixen by Alcatel Vacuum Technology

PASCAL series

82

10

0,5

1

1,5

-3 10-2 10 -1 100 101 102 103

[cfm] pumping speed

total inlet pressure [Torr]

2002

10

2

4

6

8

10

12

-3 10-2 10 -1 100 101 102 103

[cfm] pumping speed

total inlet pressure [Torr]

2015

2005

10

2

4

6

8

10

12

-3 10-2 10 -1 100 101 102 103

[cfm] pumping speed

total inlet pressure [Torr]

1005

1015

2002I2005I/C1 - 2010I/C1/C2

2015I/C1/C2 - 2021I/C1/C2

2005SD - 2010SD 2015SD - 2021SD 2005H1 - 2015H1

1005SD - 1015SD2033SD/C1/C2/H12063SD/C1/C2/H1

Pumping curves 60 Hz

10

2

4

6

8

10

12

-3 10-2 10 -1 100 101 102 103

[cfm] pumping speed

total inlet pressure [Torr]

2021

2015

2010

2005

10

2

4

6

8

10

12

-3 10-2 10 -1 100 101 102 103

[cfm] pumping speed

total inlet pressure [Torr]

2021

2015

2010

2005

10

10

20

30

40

50

60

-3 10-2 10 -1 100 101 102 103

[cfm] pumping speed

total inlet pressure [Torr]

2033

2063

Rotary Vane Pumps

Page 21: Adixen by Alcatel Vacuum Technology

PASCAL series

83

Pumping curves 60 Hz

10

2010

4030

6050

8070

10090

120130

110

-3 10-2 10 -1 100 101 102 103

[cfm] pumping speed

total inlet pressure [Torr]

2100

200 40 60 80 100 120 140 160 180 20010-3

10-2

10 -1

100

10 1

10 2

10 3 [Torr] inlet pressure drop

time [mn]

V = 1m3

2005

2010

2021

2015

2100SD/C1

2005SD/I/C1/H1 - 2010SD/I/C1/C22015SD/I/C1/C2/H1

2021SD/I/C1/C2

10 20 30 40 5010-3

10-2

10 -1

100

10 1

10 2

10 3 [Torr] inlet pressure drop

time [mn]

V = 1m3

2033

2063

2033SD/C1/C2/H12063SD/C1/C2/H1

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 22: Adixen by Alcatel Vacuum Technology

PASCAL series

84

200520102015202110051015

228245270291228245

Dimensional drawings

2005SD/I/C1 - 2010SD/I/C1 - 2015SD/I/C1 - 2021SD/I/C11005SD - 1015SD

226259

Drain 3/8 G

141164237

95.5

454.

516

5

19.5

240

221

216

100

98

37

Fill hole3/8 G

L63

19237

96.5

inletNW 25

91.5

NW25exhaust

Model

Specific dimensions

*same dimensions for single and three-phase motors

L mm

141

4.5

16522

1

216

100

98

122

InletNW 25

2126

358NW25exhaust

1/8 NPTBubbler inlet

37 37

2005H1 - 2015H1

Casing drain plug 3/8 GIntermediate compartment drain plug 3/8 G

B

226259

258

141

74.5 4.5

19.5

240

221

208.

5

100

98

A

139 84

19224

NW 25 inlet

Oil sight glass

Fill plug 3/8 G(casing & intermediatecompartment)

NW25 exhaust Oil sight glass

Model A mm

20052015

279310

B mm

195226

Specific dimensions

2010C22015C22021C2

Rotary Vane Pumps

Page 23: Adixen by Alcatel Vacuum Technology

PASCAL series

85

2033SD - 2063SD

375/459

206/229

288/342 103

exhaust

Inlet

118a b

140/190

Drain plug 3/8 G

Types 33/63

L455/529

31/29

437/521

D

336/

385

164/

186

12 12

H

53NW 40

Fill plugGas ballast56

4245

213/264

323/

371

1 G1/4

362

to 3

8541

0 to

422

Motortype

2033

VDECSAJIS

UL/CSACE

Lmm

224212246

240

Dmm

180184180

185

Hmm

135132135

142

amm

255.526

25.5

265

bmm

868786

87

Specific dimensions according to motors

Motortype

2063

VDECSAJIS

UL/CSACE

Lmm

290285290

285

Dmm

196195196

195

Hmm

140140140

149

amm

26.525

26.5

25

bmm

868786

87

Specific dimensions according to motors

2033C1 - 2063C1

375/459206/229

288/342 103

Oil filter

118a b

140/190

Drain plug 3/8 G

Types 33/63

L452/5269191

31/29

437/521

D

Ø 7

6

336/

385

164/

186

12 12

H

53NW 40

Fill plugGas ballast56

4245

213/264

323/

371

438

to 4

4738

9 to

398

Oil casing purge1/8 NPT

Inert gas inlet1/8 NPT

InletExhaust 1 G1/4

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 24: Adixen by Alcatel Vacuum Technology

PASCAL series

86

Dimensional drawings

2033C2 - 2063C2

375/459206/229

288/342 103118

a b

140/190

L

455/529

31/29

437/521

D

336/

385

164/

186

12 12

H

5356

4245

213/264

323/

371

353/

402

Drain plug 3/8 G

Types 33/63

Oil temperaturesensor connectionM10

NW 40

Fill plug Oil pressure sensorconnection1/8 NPT

Bubbler connection1/8 NPT

Oil casing purge1/8 NPT

Pump rotationsensor connection

Gas ballast 1/8 NPT

inlet

Exhaust 1 G1/4

2033H1 - 2063H135

8/37

436

4/38

5

170/

186

DH

12

140/190213/264

198/221

bL

a

518.5/586

Casingdrainplug3/8 G

Intermediatecompartementdrain plug3/8 G

Oil sightglass

295/349

Inlet NW 40

Intermediatecompartmentfill plug 3/8 G

Water coolinginlet & outlet 1/8 GTypes 33/63

121.5137

459/375437/521 269/293

233.

5/25

0.5

69.5/58.5

62/62

35/40

69.558.5

122931

Casing fillplug

ExhaustNW 40

1 G1/4

Specific dimensions according to motors:

Rotary Vane Pumps

Page 25: Adixen by Alcatel Vacuum Technology

PASCAL series

87

785830785829785800785801

Dimensional drawings

2100SD/C1

D

244,

545

1 528

443.5

Transmissioncompartmentdrain plug3/8 G

Casing drainplug 3/8 G

Exhaust NW 50Casing fillplug

Oil sight glass523.5

11340

H 545.

5

984

b a

642.5L 33

6194

18.5 10.4

344250

Transmissioncompartmentfill plug

Inlet NW 50

Casing fill plug

Gas ballast 1 G1/4

1 G1/4

1 G1/4

2002I

Fill hole 3/8 G

Drain 3/8 G 2 holes M 5 : 71 mm between centers

127

1836

73

9743

DH

163

110

Option : inlet NW 16

Inlet NW 16

185

143

97

L32.8

Hose nipple 10 mm diam.Exhaust 1/4 G

24

29

85

112

24

64

P/N Lmm

164164190186195

Dmm

136136136136138

Hmm

9396

10295

108

Specific dimensions according to

Motortype

2100

VDECSAJIS

Lmm

310305310

Dmm

196195196

Hmm

140140140

amm

44.544.544.5

bmm

868686

Specific dimensions according to motors

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 26: Adixen by Alcatel Vacuum Technology

PASCAL series

88

5 to 21 m3/h all series ordering information

(*): For single-phase motor only. Three-phase motors are delivered without cable andplug (except for US market), but in any case codes A, J, E, K, S must be indicated.(**): for C2 series, code N is the only choice.

Rotary vane pump part numbers canbe generated using the followingtable:

Type of motorSingle phase with on/off switch

M T

Single phase w/o switch Three-phase

SCode

05

Nominal pumping speed m3/h

05

10

10

15

15

21

21Code

AE

SeriesI

SD

SD

C1

C1

C2

C2

H1

H1Code

Number of stages

1

One

2

TwoCode

Voltage configurationLow voltage

L

High voltage

HCode

Oil (**)With mineral oil

M

Without oil

NCode

Line cord set 2 m long (*)U.S.A.

A

France /Germany

E

U.K.

K

Japan

J

Switzerland

SCode

For example You need

=

Number of stages 2Nominal PumpingSpeed m3/h 05Series AEType of motor MVoltageConfiguration LLine Cord Set AOil M

2 05 AE M L A M

Rotary Vane Pumps

Page 27: Adixen by Alcatel Vacuum Technology

PASCAL series

89

Available configurations

Lubricating fluid

Example: Part number 215SDMLAM is a 2015SD series with universal single-phase motor (with on/off switch) in lowvoltage configuration, equipped with cable and 115V plug for USA, supplied with mineral oil charge.

• I/SD/C1/H1 Series: delivered withone initial charge of mineral oil( A119 for the US market; A120 forother countries).

C2 Series: factory prepared foroperation with A113 synthetic fluid;fluid must be ordered separately:see page 92 and 93.

Electrical motors

Specific motors are described page 68.

Inlet and exhaust ports

The standard configuration is bothinlet and exhaust ports in thevertical position.Horizontal positions are availableon request as specials.

SD

SD

M - S

TH

L

H

L

A - J - E - K - S

M - N

A - J - E - K - S

A - J - E - K - S

A - J

05

151

AE - SD - C1 - H1

AE - SD - C1 - C2

AE - SD - C1 - C2 - H1

AE - SD - C1 - C2

05

10

15

21

2

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 28: Adixen by Alcatel Vacuum Technology

PASCAL series

90

786008

786012

785849

794287

785263

054113

786021

786022

785848

794290

785261

054402

CE/VDE530

∆/Y

220/380

240/415

220/380

280/480

∆/Y

230/400

230/460

255/440

2033 SD

2033 C1

2033 C2

2033 H1

Exhaust pressure < atm

Exhaust pressure > atm

Motor P/N

2063 SD

2063 C1

2063 C2

2063 H1

Exhaust pressure < atm

Exhaust pressure > atm

Motor P/N

Standards

Frequencies

Name plate

50 Hz

60 Hz

Other possible voltages

50 Hz

60 Hz

33 - 63 m3/h (27-50 cfm) all series ordering information

(*) : add L or H to the part number for desired Low or High voltage configuration.(**) : specific motor for US market, featuring a 12 pin terminal box.

UT2033SD (*)

UT2033C1 (*)

UT2033C2 (*)

UT2033H1.B (*)

UT2033H1.A (*)

054062(**)

UT2063SD (*)

UT2063C1 (*)

UT2063C2 (*)

UT2063H1.B (*)

UT2063H1.A (*)

054063(**)

UL/CSA/CE

∆∆/∆

190.220/380

200.230/460

∆∆/∆

/440

/380

Pump model PART NUMBER according to three-phrase motor type

785211

785212

794212

794293

794214

054112

785214

785215

794213

794292

794215

054461

CSA/CE

∆/Y

220/380

240/415

220/380

280/480

∆/Y

230/400

230/460

255/440

794226

794227

794228

794285

794229

065973

794217

794218

794219

794286

794220

065974

CE/JIS

200

200

220

Voltage

ImportantIn order to get expected perfor-mances from pump and motor ; it is important to make sure thatelectrical power is supplied with

Rotary Vane Pumps

Page 29: Adixen by Alcatel Vacuum Technology

PASCAL series

91

Lubricating fluidSD.I.C1.H1 series: one initial chargeof mineral oil (A119 for US market;A120 for other countries).C2 series: factory prepared for operation with A113 synthetic fluid;fluid must be ordered separately: see page 92 and 93.

Electrical motorsThey are supplied with power cableand plugs for single phase types; andwithout for three phase types.Single phase and three phase motorsare available in different versions complying with major international standards: VDE/UL/CSA/JIS.Specific motor for pumps from 5 to 21 m3/h are described page 68.Special motors are available on

100 m3/h (90 cfm) all series ordering information

786030

UT2100SD for USA*

786510

UT2100C1 for USA*

083449

CE/VDE530

∆/Y

220/380

240/415

220/380

280/480

∆/Y

230/400

230/460

255/440

2100SD

2100C1

Motor P/N

Standards

Frequencies

Name plate

50 Hz

60 Hz

Other possible voltages

50 Hz

60 Hz

Pump model PART NUMBER according to three-phrase motor type

794270

UT2100SD for USA*

794271

UT2100C1 for USA*

054502

CSA

∆/Y

220/380

240/415

220/380

280/480

∆/Y

230/400

230/460

255/440

794272

794273

065975

CE/JIS

200

200

220

Voltage

PASCAL series rotary vane pumpsare delivered with the following:

785830

A120

052090

CE/CSA

220/240

2002I

Oil type

Motor P/N

Standards

Frequencies

50 Hz

60 Hz

Pump model PART NUMBER according to single-phrase motor type

785829

A119

052093

CSA

100/110

100/115

785800

A120

052093

CSA

100/110

100/115

785801

A120

052094

CSA

200/220

200/230

795756

UM2002I for USA

A119

100157

UL/CSA/CE

115

208/230

Voltage

2 m3/h (1.4 cfm) ordering information

*

* : add L or H to the part number for desired high or low voltage configuration.

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 30: Adixen by Alcatel Vacuum Technology

PASCAL series

92

A119

A120

A121

A102

A111

A113

A200

A300

A155

Oils and fluids

Rotary vane pumps are mechanicalpumps in which lubricating fluidperformes three major functions:• lubrication between moving parts• heat exchange between pumping

module and oil casing cooling fins.• internal clearance reduction

between moving parts for high compression ratio.

In order to achieve the desiredultimate pressure, oils and fluidsmust have very low saturatedvapor pressure and specificviscosities within the internaltemperature range of the pumps.

Alcatel has selected high quality oilsand fluid, suitable for a wide rangeof applications.Selection of the appropriated fluidmust take into considerationoperating conditions as well as gascorrosion.

PASCAL series rotary vane pumpscan be operated with other oils thanthe ones listed below; using differentoils can affect all specified ultimate

PASCAL series rotary vane pumpsare delivered with the followingLubricating fluid:

¥ SD. I. C1. H1 series: one initialcharge of mineral oil (A119 for US market; A120 for other countries).¥ C2 series: factory prepared foroperation with A113 synthetic fluid;fluid must be ordered separately.

Type Vapor pressure Viscosity DensityFlashpoint

Applications

mineral oil

Paraffin basedmineral oilspecial hydrocarbon,based mineral oilmineral oil

hydrocarbon basedsynthetic oilPFPE synthetic fluidvacuum distilledmineral oildouble distilledhydrocarbon basedmineral oilsynthetic di-ester fluid

4.10-5 mbar at 25°C

1.3.10-6 mbar at 65°C

6.6.10-7 mbar at 25°C

10-2

mbar at 65°C

10-6 mbar at 65°C

6.10-5 mbar at 100°C

6.10-6 mbar at 25°C

2.10-6 mbar at 25°C

10-3 mbar at 100°C

54 cst at 40°C8.1 cst at 100°C118 cst at 40°C

12.5 cst at 100°C67 cst at 38°C

98 cst at 40°C11.1 cst at 100°C

100 cst at 40°C7.8 cst at 100°C100 cst at 40°C11 cst at 100°C58 cst at 40°C

8.5 cst at 100°C56 cst at 40°C

8.9 cst at 100°C

94 cst at 40°C9.1 cst at 100°C

0.860

0.886

0.830

0.880

0.870

1.9

0.860

0.860

0.957

213°C

260°C

296°C

230°C

212°C

none

223°C

243°C

252°C

general purposes, non corrosivegases, low temperature startinggeneral purposesnon corrosive gaseshigh pressure and high temperature, frequent cyclinganti-emulsionwater vapor and organicacids vapor pumpinghigh pressure and hightemperatureoxygen and highly corrosivegases pumpinglow backstreamingchemical resistancehighly resistant to chemicalattack, pumping of Lewis acid,halogens...pumping of NH3 andhydrocarbon vapors.R134a initial circuit evacuation.Resistant to oxidation, avoidformation of deposits

Rotary Vane Pumps

Page 31: Adixen by Alcatel Vacuum Technology

PASCAL series

93

Oils and fluids ordering information

Optional "inert" fluid pump preparationFactory preparation of new rotaryvane pump with ALCATEL 113 PFPEfluid is necessary for all series (except C2 series).

PFPE fluidThe PFPE fluid must be orderedseparately (see above).Class B preparation includes:complete pump disassembly, degreasing and reassembly with newviton seals and re-certification ofpump to specifications with PFPE fluid.

PART NUMBERContainer size

Other countriesUSAOil Type

103855

068099068844010991102724010996068853010987

064655068854

064657064659068694

068695068696068890

068891068892109233

1 liter1 gallon55 gallons2 liters5X2 liters56 liters1 liter2 liters5X2 liters56 liters1 liter2 liters5X2 liters1 kg2 kg8 kg0.5 liter2.5 liters1 liter1 gallon55 gallons3.8 liters19 liters1 liter1 gallon55 gallons3.8 liters19 liters1 liter

A119

A120

A121A102

A111

A113

A200

A300

A155

981019810298103

14128010996

064656

987039870498705

982019820298203

983019830298303

109233

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 32: Adixen by Alcatel Vacuum Technology

PASCAL series

94

In order to simplify maintenance performed in the field, ALCATEL offers maintenance kits including interchangeable components:• Minor kit includes all necessary seals (shaft seals, o-rings, valves...).• Major kit includes Minor kit plus vanes, springs, plugs...• Shaft seal kit includes all

components (lip seals, shaft sleeve...) necessary for fast periodic renewal ofexternal shaft sealing. (only for 5 to 21 m3/h SD,I,C1,C2 series).

Maintenance kits ordering information

Shaft seal kitMinor kitMajor kitModel

--

065612065612065612065612065875065875065875065875065612065612065612065612065612065612065612

--

065875065875065875065875065612065612065612065612

052133104420103912103912103912103912103911103911103911103911104975104975104975104975104975104975104975104611104611103911103911105515105515104975104975104975104975

052132104421103906103907103908103909103902103903103904103905104976104977104978104979104614104615104616104612104613104622104623104643104644104617104618104619104620

Minor kitMajor kitModel

054285054485083282054286054488054663065123065552054282054483054285054485054286054488

054288054487054595054289054489054664065124065553054283054484104416104417104418104419

2033 SD2063 SD2100 SD2033 C12063 C12100 C12033 C22063 C22033 H12063 H11033 SD1063 SD1033 C11063 C1

2002 I2002 C12005 I2010 I2015 I2021 I2005 SD2010 SD2015 SD2021 SD2005 C12010 C12015 C12021 C12010 C22015 C22021 C22005 H12015 H11005 SD1010 SD1015 SD1021 SD1005 C11010 C11015 C11021 C1

Rotary Vane Pumps

Page 33: Adixen by Alcatel Vacuum Technology

PASCAL series

95

Configuring and optimizing rotaryvane pumps operation for someapplications requires the use ofdifferent accessories.ALCATEL has developed a full line ofaccessories to be used with thePASCAL series.These accessories have been designed in order to facilitate operation, assembly anddisassembly; inlet and exhaust

flanges comply with ISO-KF standard.For some applications, the use ofaccessories may be the best way toenhance performance and reliabilityof vacuum systems.Our specialists can assist you inmaking the proper selection.

Accessories

A full and comprehensive line of accessories.

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 34: Adixen by Alcatel Vacuum Technology

96

PASCAL seriesRotary Vane Pumps

ST 25 COME 25 S OME 25 HP

DE 2

OME 50 C

LNT 25 P1

LNT 25 C

OME 40 C1

Page 35: Adixen by Alcatel Vacuum Technology

97

PASCAL seriesRotary Vane Pumps

ROU

GH

ING

PU

MPS

2100

C1

2100

SD

2033

- 20

63 H

1

2033

- 20

63 C

2

2033

- 20

63 C

1

2033

- 20

63 S

D

2005

- 20

15 H

1

2010

- 20

21 C

2

2005

- 20

21 C

1

2005

- 20

21 S

D

2005

- 20

21 I

2002

C1

2002

IOil mist eliminatorsOME 2002 IOME 2002 COME 25 SOME 25 HPOME 25 C/HOME 40 SOME 40 C1OME 40 C2OME 40 HOME 50 SOME 50 C

● ● ●

● ●

Oil drain kitsODK 1ODK 2

Liquid nitrogen trapsLNT 25 SLNT 25 CLNT 25 P1LNT 25 P2LNT 40LNT 50

❍ ● ●

Sorption trapsST 25 SST 25 CST 40ST 50

Dust filterDFT 25DFT 40

● ●

Condensate trap● ● ❍ ❍

Remote gas ballastAGB 4AGB 36

● ● ❍

● ❍

External oil filtersDE 1DE 2

● ● ●

Oil level switchesOLS 4OLS 36

● ●

● : Possible without restrictions ❍ : Possible with restrictions

Page 36: Adixen by Alcatel Vacuum Technology

PASCAL series

98

Rotary Vane Pumps

Oil mist eliminators

������

OME 2002

Rc 1/4

73

Ø 16Ø 44

5110

OME 2002 I❏ material:............ body: aluminum

........................ cartridge: epoxy/glass micro-fiber❏ weight:.............. 0.1 kg 0.22 lbs❏ inlet port: .......... thread RC 1/4"❏ exhaust port:...... Ø 16 mm❏ P/N: ................................................ 062886

❏ replacement cartridge (single): P/N 062824

200.

8

7G1/4 NFE 03-005

Ø 19

33.9

168

10.5

60

604.

58.

5

6 27

31.5

DN 25

Ø 54

O-Ring

OME 2002 C❏ material:............ body : stainless steel

........................ cartridge : PTFE/glass micro-fiber❏ weight:.............. 0.9 g 2 Ibs❏ inlet port: .......... thread RC 1/4"❏ exhaust port:...... DN25 ISO-KF❏ P/N: ................................................ 104378

❏ replacement cartridge (set of 5): P/N 066806

50

50DN 25

DN 25

Square 62 x 62

148

118

DN 25

50

DN 25

118

Dimensions in mm

Exhaust pump

OME 25 S❏ material: ............ body : polyamide

........................ cartridge : epoxy/glass micro-fiber❏ weight: ................ 0.217kg 0.477 Ibs❏ inlet port/exhaust port: DN25 ISO-KF❏ P/N: ................................................ 104200

❏ replacement cartridge, set of 5: P/N 068838single: P/N 068304

❏ supplied with: 1 centering ring, 1 clamp, 1 additional angle port

During rotary vane pump operation, oil mist escapes fromthe exhaust port; mainly when pumping betweenatmospheric pressure and 1 mbar.

Oil mist eliminators retain oil mist contained in theexhausted gases with a high level of separation; an internal over pressure valve prevents exceeding the maximum permissible exhaust pressure.

Page 37: Adixen by Alcatel Vacuum Technology

PASCAL series

99

Rotary Vane Pumps

Dimensions in mmSquare 86 x 86

DN 25

Sight glass

DN 25

Ø 86

57

200

3211

Square 95 x 959 Exhaust pump

Drain(G 1/8)

OME 25 HP/HP+Specially designed for applications involving frequentcycling or high pressure operation; OME 25 HP is mainlydedicated to 15 m3/h and 21 m3/h rotary vane pumps.

❏ material:............ body : aluminum........................ cartridge : epoxy/glass micro-fiber

❏ weight:.............. 1.2 kg 2.64 lbs❏ inlet port/exhaust port: DN25 ISO-KF❏ P/N: ................................................ 104199

❏ replacement cartridge (single): P/N 100522❏ supplied with: 1 centering ring and 1 clamp

Same design as OME HP, incorporating a more efficientcartridge : OME25HP+ is the next step toward completelyoil free exhausted gases.

❏ P/N:..................................................108341

❏ replacement cartridge (single): P/N 107494(materials: PU/PET/glass micro-fiber/PA)

Ø 54Exhaust DN 25

157

DN 25Square 60 x 60

OME 25 C/H

PU

MP

OME 25 C/HFor applications involving corrosive gases or high level of tightness.

❏ material:............ body : stainless steel........................ cartridge : PTFE/glass micro-fiber

❏ weight:.............. 0.530 kg 1.77 Ibs❏ leak rate: .......... ≤ 2.10 -7 mbar l/s❏ inlet port/exhaust port: DN25 ISO-KF❏ P/N: ................................................ 066849

❏ replacement cartridge set of 5: P/N 066806❏ supplied with: 1 centering ring and 1 clamp

338

DN 40

DN 40 Exhaust pump

Ø 140

OME 40 S❏ material: ............ body: aluminum

........................ cartridge: epoxy/glass micro-fiber❏ weight: ................ 0.9kg 1.9 Ibs❏ inlet port/exhaust port: DN40 ISO-KF❏ P/N: ................................................ 104887

❏ replacement cartridge (single): P/N 068443

ROU

GH

ING

PU

MPS

Page 38: Adixen by Alcatel Vacuum Technology

PASCAL series

100

Rotary Vane Pumps

Ø 104Drain 3/8 G

ExhaustOillevel

85

37

120

1421

7

125

372

102

170

DN 40

DN 4

0

Ø 138

Ø 4

2.4

OME 40 C1

For applications involving corrosive gases, except fluorinated gases.

❏ material:............ body: stainless steel........................ cartridge: PTFE/glass micro-fiber

❏ weight:.............. 4.1 kg 9 lbs❏ inlet/exhaust port: DN40 ISO-KF❏ P/N: ................................................ 068785

❏ replacement cartridge (single): P/N 068778

Ø 104Drain 3/8 G

Exhaust pumpOil level

85

83

120

85

Ø 4

2.4

223

308

100

170

DN 40

DN 4

0

Ø 138

~ 0.

8 lit

re

OME 40 C2

Suitable for corrosive applications involving fluorinated gases.

❏ material:............ body : stainless steel........................ cartridge : polypropylene

❏ weight:.............. 4.1 kg 9 Ibs❏ inlet/exhaust port: DN40 ISO-KF❏ P/N: ................................................ 068942

❏ replacement cartridge (single): P/N 100802

Ø 104Drain 3/8 G

ExhaustOillevel

85

37

120

1421

7

125

372

102

170

DN 40

DN 4

0

Ø 138

Ø 4

2.4

OME 40 H

Specially designed for applications involving high level of tightness.

❏ material: ............ body: stainless steel........................ cartridge: epoxy/glass micro-fiber

❏ weight: ................ 4.1 kg 9 Ibs❏ leak rate ..............≤ 2.10 -7 mbar.I/s❏ inlet/exhaust port: DN40 ISO-KF❏ P/N: ................................................ 068744

❏ replacement cartridge (single): P/N 068443

Page 39: Adixen by Alcatel Vacuum Technology

PASCAL series

101

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Ø 33.7

Ø 138

331

DN 50 Exhaust pump

103

OME 50 S

❏ material: ............ body: steel........................ cartridge: cellulose

❏ weight: .............. 3.5 kg 7.7 lbs❏ inlet port: .......... DN50 ISO-KF❏ exhaust port: .... Ø 33.7 mm 11/3 inch❏ P/N: ................................................ 104888

❏ replacement filter (1 set): P/N 082672

132

355

102

288

35

DN 50

DN 50

Exhaust�

����

Oil level

Drain

Drain

Ø 200

OME 50 C

❏ material: ............ body: stainless steel........................ cartridge: PTFE/glass micro-fiber

❏ weight: .............. 9 kg 19.8 Ibs❏ inlet/exhaust port: DN50 ISO-KF❏ P/N: ................................................ 068996

❏ replacement cartridge (single): P/N 068778(3 are necessary)

Page 40: Adixen by Alcatel Vacuum Technology

PASCAL series

102

Rotary Vane Pumps

ODK 1 for 5 to 21 m3/h pumps I/SD series

Oil Drain Kit 1 must be used with oil mist eliminator OME 25 HP. It consists of a drain pipe which isconnected on one end to the bottom of the OME 25 HP,and on the other end to the inlet of the gas ballast. When operating the pump at high pressure, the oil accumulatedin the OME HP is re-injected through the gas ballast.*When using ODK 1, the pump is not tight when stopped

❏ weight: ................ 0.3 kg 0.66 Ibs❏ part numbers

230 V 115 V 100 V 200 V 24 V DC

50/60 HZ 60 HZ 50/60 HZ 50/60 HZ

P/N 104361 104362 104363 104364 104365

Oil drain kits

58

26 18.5

Drain plug G 1/8" NFE 03-005

Oil misteliminator

OME25 HP

RVPPascal

Pipe Ø 6/4

Tank crossingof gas ballast

G 1/8"NFE 03-005

58

74.5 23.5

Drain plug G 1/8" NFE 03-005

Oil misteliminator

OME25 HP

RVPPascal

Pipe Ø 6/4Tank crossingof gas ballast

G 1/8"NFE 03-005

ODK 2 for 5 to 21 m3/h pumps I/SD series

Oil Drain Kit 2 is similar to ODK 1 with a NC solenoidvalve located at the inlet of the gas ballast.The valve must be energized by the same electrical supply as the pump; in case of power failure, the valvewill close and the pump will stay tight when stopped.

❏ weight: ................ 0.1 kg 0.22 Ibs❏ P/N: ................................................ 104360

P/N

Page 41: Adixen by Alcatel Vacuum Technology

PASCAL series

103

Rotary Vane Pumps

Liquid nitrogen trapsLiquid nitrogen traps condense at the pump inlet all gaseswhose critical condensation temperature is above-196° C (77K). They can be used either to protect the pumpagainst condensable vapor introduction or to prevent

backstreaming of oil vapors at the pump inlet when anabsolutely clean vacuum is desired (exhaust of moleculardrag or turbomolecular pumps)

64 64

Ø 19,5

Square 95x95

242,

5

Square 86x86

DN 25

DN 25

Dimensions in mmLNT 25 S

❏ material: ............ body: aluminum........................ thimble: stainless steel

❏ weight: .............. 1.690 kg 3.72 lbs❏ liquid nitrogen capacity: 0.5 l❏ inlet/exhaust ports: DN25 ISO-KF❏ conductance ❏ fill interval

❏ supplied with: 1 centering ring and 1 clamp❏ P/N:.................................................. 104197

68 68

Aperture Ø19,5

Square 94 x 94

DN 25

DN 25

146

Ø 84

5

DN 25

Dimensions in mm

�y�y����yyyy�y

292

80

Ø 52Ø 28

DN 25

Sphere Ø 130

DN 25

120 120

conductance inlet pressure

44 l/s 10 -1 mbar

10 l/s 10 -2 mbar

fill interval inlet pressure

5h 10 -2 mbar

11h ultimate

LNT 25 C❏ material: ............ body: stainless steel

........................ thimble: stainless steel❏ weight: .............. 1.885 kg 4.15 lbs❏ liquid nitrogen capacity: 0.5 l❏ inlet/exhaust ports: DN25 ISO-KF❏ conductance ❏ fill interval

❏ supplied with: 1 centering ring and 1 clamp❏ P/N: ................................................ 066889

LNT 25 P1❏ material: ............ body: glass

........................ flanges: aluminum❏ weight: .............. 1kg 2.2 lbs❏ liquid nitrogen capacity: 0.5 l❏ inlet/exhaust ports: DN25 ISO-KF❏ conductance ❏ fill interval

❏ P/N: ................................................ 786346

conductance inlet pressure

33 l/s 10-1 mbar

6 l/s 10-2 mbar

fill interval inlet pressure

5h30 10-2 mbar

14h ultimate

conductance inlet pressure

6 l/s 10-2 mbar

fill interval inlet pressure

5h ultimate

ROU

GH

ING

PU

MPS

Page 42: Adixen by Alcatel Vacuum Technology

PASCAL series

104

Rotary Vane Pumps

340

80

Ø 152Ø 28

DN 25

Sphere Ø 170

DN 25

120 120

LNT 25 P2❏ material : .......... body : glass

........................ flanges : aluminum❏ weight : ............ 1.5 kg 3.3 lbs❏ liquid nitrogen capacity : 1 l❏ inlet/exhaust ports : DN25 ISO-KF❏ conductance ❏ fill interval

❏ P/N : .............................................. 786347

133

366

4682

Ø 14(I.D.)

DN 40

Ø 114.3100 100

DN 40

Drain port M8

340

66851

2

Fill hole Ø 29

DN 50

93

Ø 229

158 158

120

DN 50

Drain4 holes Ø 9

conductance inlet pressure

6 l/s 10-2 mbar

fill interval inlet pressure

6h ultimate

❏ material : .......... body : stainless steel........................ thimble : stainless steel

❏ weight : ............ 3 kg 7.2 lbs❏ liquid nitrogen capacity : 1 l❏ inlet/exhaust ports : DN40 ISO-KF❏ conductance ❏ fill interval

❏ P/N : .............................................. 786537

conductance inlet pressure

43 l/s 10-2 mbar

fill interval inlet pressure

15h ultimate

❏ material : .......... body : stainless steel........................ thimble : stainless steel

❏ weight : ............ 20 kg 48 lbs❏ liquid nitrogen capacity : 6 l❏ inlet/exhaust ports : DN50 ISO-KF❏ conductance ❏ fill interval

❏ P/N : .............................................. 786530

conductance inlet pressure

110 l/s 10-2 mbar

fill interval inlet pressure

15h ultimate

LNT 40

LNT 50

Page 43: Adixen by Alcatel Vacuum Technology

PASCAL series

105

Rotary Vane Pumps

Sorption traps

Sorption traps consist of a sealed body filled with adsorbentmedia whose extremely porous surfaces adsorb water orhydrocarbon molecules contained in the pumped gases.Sorption traps provide simple and effective protection against

oil backstreaming whenever clean vacuum is desired. The saturated adsorbent elements can be regenerated byheating (baked out in oven, or using integrated heater,according to models).

Square 86 x 86

DN25

RP

Dimensions in mmSquare 95 x 95

Ø 86DN 25

50

64

150

192

ST 25 S

❏ material: ............ body: aluminum........................ cartridge: stainless steel

❏ weight: .............. trap: 1.15 kg 2.53 lbs........................ adsorbent: 0.36 kg 0.79 Ibs

❏ inlet/exhaust ports: DN25 ISO-KF❏ conductance

❏ P/N: ............................ 104107 - without adsorbent charge❏ adsorbent charge: activated alumina: P/N 068779

........................ zeolite: P/N 068182❏ supplied with: 1 centering ring and 1 clamp

DN16

DN 25 DN 25

80 80Ø 114,3

90

135

164,

4

2,5

Dimensions in mm

conductance inlet pressure45 l/s 10-1 mbar11 l/s 10-2 mbar

❏ material: ............ body: stainless steel........................ cartridge: stainless steel

❏ weight: .............. trap: 1.4 kg 3.08 lbs........................ adsorbent: 0.26 kg 0.57 Ibs

❏ inlet/exhaust ports: DN25 ISO-KF❏ conductance

❏ P/N: 066845 for 115V - without charge

❏ P/N: 066841 for 220V - without charge

❏ adsorbent charge: activated alumina: P/N 068779........................ zeolite: P/N 068182

❏ heating element: 115V P/N 066876........................220V P/N 068319

❏ supplied with: 1 centering ring and 1 clamp

ST 25 CWith electrical heating element

conductance inlet pressure45 l/s 10-1 mbar20 l/s 10-2 mbar

ROU

GH

ING

PU

MPS

Page 44: Adixen by Alcatel Vacuum Technology

PASCAL series

106

Rotary Vane Pumps

❏ material: ............ body: stainless steel........................ cartridge : stainless steel

❏ weight: .............. trap: 1.7 kg 3.74 lbs........................ adsorbent: 0.36 kg 0.79 Ibs

❏ inlet/exhaust ports: DN40 ISO-KF❏ conductance

❏ P/N: 104371 115V- 053380 220V-with zeolite charge

❏ adsorbent charge: activated alumina: P/N 068779........................ zeolite: P/N 068182

❏ heating element: 115V P/N 066876 ........................220V P/N 068319

��

91

DN

40

DN

40

Ø 114

115

2,5

165

195

ST 40 not available in USAWith electrical heating element

❏ material: ............ body: stainless steel........................ cartridge: stainless steel

❏ weight: .............. trap: 2 kg 4.4 lbs........................ adsorbent: 0.36 kg 0.79 Ibs

❏ inlet/exhaust ports: DN50 ISO-KF❏ conductance

❏ P/N: 104372 115V - 053381 220V-with zeolite charge❏ adsorbent charge: activated alumina: P/N 068779

........................ zeolite: P/N 068182❏ heating element: 115V P/N 066876

........................220V P/N 068319

ST 50 not available in USAWith electrical heating element

��

97

DN

50

DN

50

Ø 114

145

2,5

200

230

conductance inlet pressure

25 l/s 10 -2 mbar

conductance inlet pressure

30 l/s 10 -2 mbar

Page 45: Adixen by Alcatel Vacuum Technology

PASCAL series

107

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

❏ material: ............ body and cartridge: stainless steel❏ weight: lbs

❏ dimensions: inch

❏ ordering information

FTML25 FTML40 FTML50trap 3.1 3.74 4.4charge 0.57 0.73 0.86

H1 H2 H3 L AFTML 25 5.12 3.54 2.36 3.35 4.53FTML 40 8.46 6.89 4.72 3.54 4.53FTML 50 8.46 6.89 4.72 4.33 5.91

P/N trap alumina charge heater 115V

FTML 25 55014 55020 55021

FTML 40 55016 55020 55022

Specific sorption traps for USA customers - FTML 25/40/50 With 115V heating element

��

L

A

H3 H2 H1P/N

Page 46: Adixen by Alcatel Vacuum Technology

PASCAL series

108

Rotary Vane Pumps

Inlet dust filterUsing inlet dust filters will prevent solid particles fromentering into the rotary vane pump and avoid concentrationof solid media which can act as abrasive and shorten the

pump lifetime. Periodic maintenance is required in order tokeep highest pumping efficiency.

50

55 DN 25

DN 25

Square 62 x 62

148

118

DN 25

50

DN 25

118

Dimensions in mmDFT 25

❏ material: ............ body: polyamide........................ cartridge: epoxy/glass micro-fiber

❏ weight: .............. 0.217 kg 0.45 lbs❏ filtration threshold: 6 µm❏ conductance

❏ inlet/exhaust ports: DN25 ISO-KF❏ P/N: .................................................. 104202

❏ replacement cartridge (set of 5) P/N 068837❏ supplied with: 1 centering ring and 1 clamp

1 additonal angle port

335

DN 40

71

163

DN 40

Ø 292

1280

350

200

Ø 288

170

280

170

DN 50

DN 50

Ø 250

conductance inlet pressure

2 l/s 10-1 mbar

0.6 l/s 10 -2 mbar

DFT 40

❏ material: ............ body: steel........................ cartridge: PVC foam

❏ weight: .............. 3.9 kg 8.58 lbs❏ filtration threshold: 5 µm❏ conductance

❏ inlet/exhaust ports: DN40 ISO-KF❏ P/N: .................................................. 104889

❏ replacement cartridge (set of 26) P/N: 068485

DFT 50❏ material: ............ body: steel

........................ cartridge: PVC foam❏ weight: .............. 50kg 10 lbs❏ filtration threshold: 5 µm❏ inlet/exhaust ports: DN50 ISO-KF❏ P/N: .................................................. 104890

❏ replacement cartridge (set of 19) P/N: 068486

conductance inlet pressure

44 l/s 10 -1 mbar

12 l/s 10 -2 mbar

Page 47: Adixen by Alcatel Vacuum Technology

PASCAL series

109

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

❏ material: ............ body: aluminum........................ filter: stainless steel

❏ trap capacity: .... 0.6 l❏ weight : ............ 1.2 kg 2.64 lbs❏ conductance

❏ inlet/exhaust ports: DN25 ISO-KF❏ P/N: ...................... 104201

❏ replacement filter P/N: 066825❏ supplied with: 1 centering ring and 1 clamp

Condensate traps

Using condensate traps at the pump inlet will preventintroduction of some solid or liquid products (foam,deposits...) which could mix with the oil and reduce pumplifetime. Pumped gases pass through metalic filter andstainless steel wool which retain particles, solid deposits and

ensure liquid coalescence. Used at the exhaust, condensatetrap can trap oil mist when operating the pump at highpressure; it can be used along with conventional oil misteliminator.

202

DN 25

50

Square 86 x 86

PPM

5740

5

Square 95x95Ø 86

Drain

9

Dimensions in mm

CT 25

conductance inlet pressure

15 l/s 10-1 mbar

6 l/s 10-2 mbar

Page 48: Adixen by Alcatel Vacuum Technology

110

PASCAL seriesRotary Vane Pumps

Remote controlled gas ballast

Electrically operated gas ballast is the remote controlledversion of the manual gas ballast of the rotary vane pump. It consists of a Normally Closed solenoid valve which enablesair injection into the high pressure stage of the pump.

The Automatic Gas Ballast can be connected to a source ofdry and neutral gas; it is a convenient solution in all casesof frequent use or difficult access to the manual gas ballast.

75

58

50

118

Electrical cablelength = 600 mm

Dimensions in mm

AGB 4 for 5 to 21 m3/h pumps I/SD/C1 series

❏ delivered with: 600 mm cable (without plug)all necessary connection parts

❏ weight: .............. 0.3 kg 0.66 lbs❏ ordering information

62.5

95.5

92.5

G1/4 NFE03-005

11.5 7.5

Filter inElectrical connection

AGB 36 for 33/63 m3/h pumps SD/C1 series

P/N 230V 115V 100V 200V 24 V50/60 HZ 60 HZ 50/60 HZ 50/60 HZ DC

AGB 4 104086 104087 104088 104366 104089

❏ delivered: without cable and plugwith all necessary connection parts

❏ weight: .............. 0.7 kg 1.54 lbs❏ ordering information

P/N 230/240V 115V 100V 200V 24V50/60 HZ 60 HZ 50/60 HZ 50/60 HZ DC

AGB 36 068391 104367 104368 104369 104370

P/N

P/N

Page 49: Adixen by Alcatel Vacuum Technology

111

PASCAL series

Oil level switches50

.79 12

05

69.91

OLS 4 for 5 to 21 m3/h pumps I.SD seriesOLS 36 for 33/63 m3/h pumps SD seriesOil Level Switch provide information about oil level inside the oil casing of the rotary vane pump. Whenever the pumpis located in an unaccessible area or whenever a largenumber of pumps is to be supervised, the OLS is a convenientsolution for remote oil level check.

❏ material:............ stainless steel/aluminum❏ weight:.............. OLS 4: 0.85 kg 1.87 Ibs

........................ OLS 36: 1.1 kg 2.42 Ibs❏ specification:

• number of contact: 2 relays• status: ..........Open when below oil level........................Closed when above oil level• switching capacity: 10 VA 250V AC/DC 0.5A• cable: ..........1m length (without plug)

❏ P/N: ........................................OLS 4 : 104376

..............................................OLS 36 : 104377

❏ supplied with all necessary components for installation on the oil casing

158

17

56,8

42

147

702448

OLS 4

OLS 36

Rotary Vane Pumps

ROU

GH

ING

PU

MPS

Page 50: Adixen by Alcatel Vacuum Technology

PASCAL series

112

External oil filters

DE 1 - DE 2

DE filters can be used with different types of filtration medias :¥ Fullers earth: external envelope/charge of activated

earth Applications: general use.

¥ Cellulose filter: filtration of solid particles only¥ Activated alumina: envelope/charge of activated alumina

Applications: mineral acids, Lewis acids, Polar compounds.¥ Activated charcoal: envelope/charge of activated

charcoal Applications: Chlorinated products, water and chlorine,Nitrous vapors, Ammonia.

DE filtration system is a stand-alone unit consisting of amagnetically driven gear pump which circulates oil throughfiltration cartridges (DE 1: 1 cartridge - DE 2: 2 cartridges).According to filtration media and number of cartridge,

DE filter retains solid particles and/or neutralizes corrosiveproducts contained in the oil of the pump. DE filters can beconnected to any rotary vane pump from 5 m3/h to 100m3/h; all necessary components for connexion are included.

390180

408

Rotary Vane Pumps

Page 51: Adixen by Alcatel Vacuum Technology

113

❏ specification/ordering information

❏ replacement cartridges

(*) 12633 for USA

❏ standard (factory installed) cartridges are :DE 1 : activated aluminaDE 2 : cellulose and activated alumina

❏ oil volume : DE 1: 1.2 l - DE 2: 1.8 l

DE1 DE2weight kg/Ibs 12/24.6 17/37.4electrical supply 110/220V 50HZ 115/230V 60 HZoil flow hydrocarbon 1000 - 1500 cm3/mn

synthetic 1000 cm3/mn at 65° C

P/N 110/115V 068991 104375

type activated activated fullers cellulosealumina charcoal earth (*)

P/N 068880 068881 068533 078212

P/N 110/115V220/230V

P/N

ROU

GH

ING

PU

MPS

PASCAL seriesRotary Vane Pumps