ADAPTPT 2010/RC 2010 to ADAPTFloor Pro 2009/2010 Strip Export Tutorial1 ADAPTFloor Pro 2009/2010 Tutorial Export Design Strip to ADAPTPT or ADAPTRC Update: May 2010 Copyright © ADAPT Corporation all rights reserved

ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

  • Upload
    vandung

  • View
    225

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 1  

 

 

 

 

 

ADAPT‐Floor Pro 2009/2010 Tutorial 

Export Design Strip to ADAPT‐PT or ADAPT‐RC 

 

 

 

 

 

 

 

Update: 

May 2010 

Copyright © ADAPT Corporation all rights reserved  

Page 2: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 2  

1 TRANSFER OF INPUT INFORMATION FROM ADAPT-FLOOR PRO TO ADAPT-PT OR ADAPT-RC AND BACKWARD TRANSFER OF TENDON DESIGN FROM ADAPT-PT TO ADAPT-FLOOR PRO

1.1 Overview

This section explains how you can export input data from ADAPT-Floor Pro to ADAPT-PT or ADAPT-RC, perform an optimal design for your post-tensioning project using ADAPT-PT or reinforced concrete project using ADAPT-RC, and have the details of your optimized post-tensioning design automatically transferred to ADAPT-Floor Pro from ADAPT-PT. The backward transfer of design information from PT to Floor Pro eliminates the initial “guesswork” involved in the selecting tendon and force layout, that are prerequisite to the designs performed using finite element programs. While ADAPT-Floor Pro does include partial tendon optimization tools, ADAPT-PT will allow a complete tendon design be performed based on the strip method. The steps involved are:

Generate a three-dimensional model of your structure in ADAPT-Floor

Pro, including the material properties, design criteria and loads.

Define support lines and create design strips in ADAPT-Floor Pro.

Export the design strips to ADAPT-PT or ADAPT-RC.

Execute the imported design strips in ADAPT-PT or ADAPT-RC and obtain optimum designs for each.

Transfer the tendon profile and force obtained in ADAPT-PT to the associated design strip in ADAPT-Floor Pro. Designs obtained in ADAPT-RC cannot be transferred back to ADAPT-Floor Pro.

Validate the tendons imported from ADAPT-PT in ADAPT-Floor Pro and use the imported tendon designs as the basis of the Floor Pro analysis.

The procedure is detailed, using the simple example shown in Figure 1-1. The intended use of this tutorial is for users who have a basic understanding and familiarity of the ADAPT-Floor Pro and ADAPT-PT programs. The steps for the creation of the example model are not covered in this document. For a more detailed process of model creation see the ADAPT-Floor Pro “Getting Started Guide.”

Page 3: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 3  

FIGURE 1-1

When opening ADAPT-Builder 2009 Concrete Design Suite, check the options as shown in Figure 1-2 if you want to export the information to ADAPT-PT. If you want to export the information to ADAPT-RC, check the options as shown in Figure 1-3.

 

 

FIGURE 1-2

Page 4: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 4  

FIGURE 1-31.1.1 Design Criteria

Thickness of slab = 10 inch

(i) Material Properties o Concrete: Compressive strength, f’c = 4000 psi Weight = 150 pcf Modulus of Elasticity = 3605 psi

o Prestressing:

Low Relaxation, Unbonded System Strand Diameter = 0.5 inch Strand Area = 0.153 inch2 Modulus of Elasticity = 29000 ksi Ultimate strength of strand, fpu = 270 ksi Minimum strand cover

From top fiber = 1.5 inch From bottom fiber

Interior spans = 1.5 inch Exterior spans = 2 inch

o Nonprestressed Reinforcement: Yield stress, fy = 60 ksi Modulus of Elasticity = 29000 ksi

Minimum Rebar Cover = 1 inch Top and Bottom

Page 5: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 5  

(ii) Loading Superimposed Dead load = 30 psf

Live load = 50 psf

Add two Patch Load over the entire slab region: 30 psf Superimposed Dead load and 50 psf Live load. Create the X and Y-direction support lines in the model as shown in Fig. 1-1.1.

FIGURE 1-1.1

1.2 Edit the Material Properties

1.2.1 Enter the Properties of Concrete (Figure 1.2-1)

Select the Normal weight and enter the strength at 28 days for slab/beam and column as 4000 psi. Consider 3605 ksi as the Modulus of Elasticity.

For this tutorial, keep the value of creep coefficient as 2. The creep coefficient will be used in the calculation of long-term deflection in ADAPT-PT. Consider Concrete strength at stressing as 2400 psi. Consider 150 pcf as unit weight of concrete.

Page 6: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6  

FIGURE 1.2-1

1.2.2 Enter the Properties of Reinforcement (Figure 1.2-2)

Enter Yield Stress of main bars and Modulus of Elasticity as 60 ksi and 29000 ksi respectively. These will be used when calculating the number of bars required. Yield stress of shear reinforcement should be entered as 60 ksi.

FIGURE 1.2-2

 

1.2.3 Enter the Post-Tensioning System Parameters

 

Select the Post-tensioning system as Unbonded and leave the default values of the other properties as they are as in Figure 1.2-3.

Page 7: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 7  

FIGURE 1.2-3

1.3 Criteria Input  

1.3.1 Criteria Input – General  

1.3.1.1 Specify the Design Code

In the Design Code screen, set the code as ACI 2008/IBC 2009 as in Figure 1.3-1.

FIGURE 1.3-1

Page 8: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 8  

1.3.1.2 Specify Tendon Height Defaults for Strip Method

The cover for the prestressing steel is specified to the center of gravity of the strand (cgs). In Tendon Height Defaults for Strip Method, edit CGS of the tendon as 1.5 inch for both the top fiber and the interior spans of bottom fiber and 2.0 inch for the exterior spans for the bottom fiber as in Figure 1.3-2.

FIGURE 1.3-2

 

1.3.1.3 Specify Rebar Minimum Cover

In Rebar Minimum Cover for non-prestressed reinforcement, edit 1.0 inch cover for both the top and the bottom as shown in Figure 1.3-3.

Page 9: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 9  

FIGURE 1.3-3

1.3.1.4 Specify Reinforcement Bar Lengths

In Reinforcement Bar Lengths, the values given as default for “minimum bar lengths” are according to ACI-318 (2008). Keep the default values (as shown in Figure 1.3-4). Note that the “Extension of strength reinforcement beyond point of zero moment” is user-defined and not necessarily equal to calculated development length per code.

The values entered for cut-off lengths are used to calculate top and bottom bar lengths when minimum reinforcement requirements govern.

FIGURE 1.3-4

Page 10: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 10  

1.3.1.5 Specify Allowable Stresses

This tab will be displayed only if the program is opened with prestressing option (PT). Typically, the allowable stresses for both the final condition (service) and initial condition (transfer of prestressing) are listed.

In Allowable Stresses option, tensile stresses are input as a multiple of the square root of f’c, and compressive stresses are input as multiple of f’c.

The default values given in Figure 1.3-5 are according to ACI 318 (2008). Leave the default values as they are.

FIGURE 1.3-5

 

 

Page 11: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 11  

1.3.1.6 Specify Shear Design Options

The shear design options are listed in a separate tab. For one-way shear (beams and one-way slabs), the program uses stirrups (links, ties), where needed. For punching shear reinforcement, you have the option to select between shear studs or stirrups.

In Shear Design Options, select Number of legs as 2 for stirrups normal to member for One-way shear reinforcement.

Select Stud and change Preferred Stud diameter and the Number of rails per side to 0.5 inch and 2 respectively for Two-way shear reinforcement as shown in Figure 1.3-6.

FIGURE 1.3-6

1.3.2 Enter the Criteria for Strip Method of Analysis and Design  

1.3.2.1 Effective Flange

In Effective Flange option, instruction to view and edit Effective Width is explained as shown in Figure 1.3-7. 

Page 12: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 12  

FIGURE 1.3-7

1.3.2.2 Specify Loading Treatments Options (Figure 1.3-8)

Answer Yes to Skip live load and enter the Skip factor as 1. Answer No to Reduce live load option. In order to calculate the self-weight automatically, you must answer Yes to Include self-weight option.

FIGURE 1.3-8

1.3.2.3 Post Tensioning Criteria

1.3.2.3.1 Specify Design Criteria for Strip Method (Figure 1.3-9)  

Page 13: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 13  

In Design Criteria for Strip Method, you can select various calculation settings. First, select the Design options as Interactive.

Next, select Yes for Reduce Moments to face-of-support option.

Select No for the option to Redistribute moments.

Select Yes for the Equivalent Frame Modeling.

FIGURE 1.3-9

1.3.2.3.2 Specify Recommended Post-Tensioning Values for Strip Method

This screen is used to specify minimum and maximum values for average precompression (P/A: total prestressing divided by gross cross-sectional area) and percentage of dead load to balance (Wbal). These values are used by the program to determine the post-tensioning requirements and the status of the Pmin/Pmax and WBAL Min/ Max indicators on the Recycle window in ADAPT-PT.

The values shown in Figure 1.3-10 are according to the selected code and the experience of economical design.

FIGURE 1.3-10

Page 14: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 14  

1.3.2.3.3 Specify Stress Loss Calculation for Strip Method  

The two design options are Force Selection and Force or tendon selection/Friction calculation. Force Selection is the default option. Keep the default option, as in Figure 1.3-11.

FIGURE 1.3-11

In this option, a tendon will be assigned a final and constant effective force, equal to the jacking force minus all stress losses, expressed as a single value.

1.3.2.3.4 Specify Tendon Profile from Tendon Library  

The program allows you to specify the profile for the tendon.

For this example, leave the default values as shown in Figure 1.3-12.

FIGURE 1.3-12

Page 15: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 15  

1.4 Generate Design Strips for Strip Method

Create design strips using the Generate Design Strips for Strip Method from the Strips pull-down menu as shown in Figure 1.4-1.

FIGURE 1.4-1

1.5 Insert Strip Method Load Transfer Insert Strip Method load transfer using the Insert Strip Method Load Transfer from the Strips pull-down menu as shown in Figure 1.5-1.

Page 16: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 16  

FIGURE 1.5-1

You need to select a support line and attach the Strip Method Load Transfer to it at the location of your choice. A window (as shown in Figure 1.5-2) gets opened after clicking on Insert Strip Method Load Transfer in which the use of inserting Strip Method Load Transfer is explained in detail. This tool is to be used where a location along a support line (or design strip) is supporting some other intersecting beam or slab strip. An example of this would be transfer girders support other beams. The tool is not intended to be used for other physical supports such as walls or columns.

FIGURE 1.5-2

Page 17: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 17  

1.6 Export to ADAPT-PT or ADAPT-RC  

1.6.1 Export to ADAPT-PT or ADAPT-RC through Strips Pull-down Menu  

Once the design strips are successfully created, you can generate input data for ADAPT-PT for all support lines or individually. You need to select a support line(s) and click on Generate Input Data for ADAPT-PT in Strips pull-down menu as shown in Figure 1.6-1.

FIGURE 1.6-1

Similarly you can generate input data for ADAPT-RC for all support lines or individually once the design strips are successfully created. You need to select a support line(s) and click on Generate Input Data for ADAPT-RC in Strips pull-down menu as shown in Figure 1.6-2.

Page 18: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 18  

FIGURE 1.6-2

You also have the option of automatically initiating the execution of individual support lines in ADAPT-PT or RC. For ADAPT-PT you need to select a support line and click on Execute in ADAPT-PT (or RC) in Strips pull-down menu as shown in Figures 1.6-3 and 1.6-4. Once selected, the program will automatically open ADAPT-PT (or RC) to begin the execution of analysis for the selected support line as shown in Figure 1.6-5.

Page 19: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 19  

FIGURE 1.6-3

FIGURE 1.6-4

Page 20: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 20  

FIGURE 1.6-5

The input data generated or exported in ADAPT-PT or ADAPT-RC is saved in its own folder under the name “Support Line #_pt” or “Support Line #_rc” in the “STRIP_MODEL/Current_plane/Support Line #” folder. ADAPT-PT and ADAPT-RC recognizes that the loaded data is from ADAPT-Floor Pro and that the outcome of the design is likely to be sent back to ADAPT-Floor Pro.

1.6.2 Export to ADAPT-PT or ADAPT-RC through Support Line Property Box

Open the support line property box of (Figure 1.6-6) by double clicking on a support line.

FIGURE 1.6-6

Click on ‘Write PT Data’ button, to write the support line input data to a subdirectory, ready to be analyzed with ADAPT-PT or ADAPT-RC.

It saves two files with *.ADB extension to be opened in ADAPT-PT or ADAPT-RC and are saved in its own folder under the name “Support Line #_pt” and “Support Line #_rc” in the “STRIP_MODEL/Current_plane/Support Line #” folder. ADAPT-PT and

Page 21: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 21  

ADAPT-RC recognize that the loaded data is from ADAPT-Floor Pro and that the outcome of the design is likely to be sent back to ADAPT-Floor Pro.

Click on ‘Rendering’ button, to obtain the idealized design tributary view in ‘ADAPT Solid Modeling’ window (Figure 1.6-7).

FIGURE 1.6-7

You can click on ‘Generate Bitmap’ button, to generate the image of the idealized design tributary in bitmap format. You can modify the model using the view and editing tools on the right side of the screen, if needed. The tools and their functionalities are listed below:

• Restore -

This button helps the user to restore all modifications done in ‘ADAPT Solid Modeling’ window.

• Edit Idealized Tributary - This button helps the user to edit the lengths, thicknesses of the spans as shown in Figure 1.6-8.

Page 22: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 22  

FIGURE 1.6-8

• Edit Support Above -

This button helps the user to edit the supports above the slab as shown in Figure 1.6-9.

FIGURE 1.6-9

• Edit Support Below -

This button helps the user to edit the supports below the slab as shown in Figure 1.6-10.

Page 23: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 23  

FIGURE 1.6-10

• Edit Beam Cross-Section -

This button helps the user to edit the supports below the slab as shown in Figure 1.6-11.

FIGURE 1.6-11

• Edit Collinear Walls -

This button helps the user to edit the supports below the slab as shown in Figure 1.6-12.

FIGURE 1.6-12

• Edit Drop Cap -

This button helps the user to edit the supports below the slab as shown in Figure 1.6-13.

Page 24: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 24  

FIGURE 1.6-13

• Edit Load -

This button helps the user to edit the loads in the spans as shown in Figure 1.6-14. Please note that at the time of export to ADAPT-PT or ADAPT-RC, the patch loads in ADAPT-Floor Pro gets converted to line loads and point loads.

FIGURE 1.6-14

• Generates a Report of the Idealized Tributary -

This button generates a MS-Word report of the idealized tributary.

• Go to PT - Once you are satisfied with the idealization of the design strip, click on the ‘Go to

PT’ button, to open ADAPT-PT with the information from the displayed design strip. This opens ADAPT-PT with the information associated with the selected support line.

• Go to RC -

Page 25: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 25  

Once you are satisfied with the idealization of the design strip, click on the ‘Go to

RC’ button, to open ADAPT-RC with the information from the displayed design strip. This opens ADAPT-RC with the information associated with the selected support line.

This opens ADAPT-PT or ADAPT-RC with the information associated with the selected support line as shown in Figure 1.6-5. The data exported in ADAPT-PT is saved in its own folder under the name “Support Line name” in the “STRIP_MODEL/Current_plane/Support Line #” folder. ADAPT-PT and ADAPT-RC recognize that the loaded data is from ADAPT-Floor Pro and that the outcome of the design is likely to be sent back to ADAPT-Floor Pro.

 

1.7 Execution of Data in ADAPT-PT or ADAPT-RC  

Once in ADAPT-PT or ADAPT-RC, the imported data fields will be grayed out, and will not be accessible for editing. The intent of locking certain data fields is to retain the compatibility of the imported data with its source in ADAPT-Floor Pro. Other information, necessary for the execution of ADAPT-PT or ADAPT-RC will be filled in with the program’s default and is available for editing. If necessary, you can unlock the data fields imported from ADAPT-Floor Pro, using the “Unlock” tool shown in Figure 1.6-5. Once you unlock the data, it is deemed to have lost its compatibility with ADAPT-Floor Pro and cannot be transferred back to ADAPT-Floor Pro (Figure 1.7-1).

FIGURE 1.7-1

Execution of the program in ADAPT-PT or ADAPT-RC is described in detail in User Manual of ADAPT-PT or ADAPT-RC.

Page 26: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 26  

Once the design is completed in ADAPT-PT and you exit the program from ‘PT Recycling’ window, the message box shown in Figure 1.7-2 will advise you that your design is available to be imported in ADAPT-Floor Pro. The data for import of design values to ADAPT-Floor Pro is saved under the file name “Support Line #.tdn” in the folder “STRIP_MODEL/Current_plane/Support Line #”. You need not open ADAPT-Floor Pro for processing the data from ADAPT-PT immediately. You can continue with the optimization of the post-tensioning of other design strips, and recall the saved data in ADAPT-Floor Pro when it is convenient.

FIGURE 1.7-2

Please make a note that design optimized in ADAPT-RC imported from ADAPT-Floor Pro cannot be recalled in ADAPT-Floor Pro.

1.8 Recall of PT Data from ADAPT-Floor Pro

To recall the optimized tendon design in ADAPT-Floor Pro, open the file of the floor system and display the support lines. Select the support line for which you intend to import the data. You may select more than one support line, if you wish to import data for multiple design strips. From the Strips pull-down menu (Figure 1.8-1) select Import Tendons From ADAPT-PT.

Page 27: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 27  

FIGURE 1.8-1

The program reads the data prepared by ADAPT-PT and displays the tendons overlapped on the support line. The design obtained in ADAPT-PT may consist of a continuous tendon over the entire length of the support line and/or a tendon that covered the part of some span and/or left/right cantilever. The short tendons terminating in middle of the spans are identified with a handle (short sloping line). The handle is a visual display intended to (a) indicate the location of terminated tendons, and (b) provide a graphic that you can select for editing the associated tendons. As an example, the data imported for design strip 1 is shown in Figure 1.8-2.

FIGURE 1.8-2

Page 28: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 28  

While being imported from ADAPT-PT, the program displays the message box of Figure 1.8-3 and it overwrites any previously imported tendons from ADAPT-PT for the same design strip that you did not validate to be retained.

FIGURE 1.8-3

The imported tendons are initialized with the “Disregard” status. They remain disregarded until you validate them.

 

1.9 Validation of PT Data in ADAPT-Floor Pro  

The imported tendons will be initially given a “Disregard” status by the program. That is, they will be displayed in the model; you can edit them, but they will not be considered in the analysis and design, unless you change their status to “Consider.” You change the status of a tendon in the FEM tab of the tendon property box (Figure 1.9-1)

FIGURE 1.9-1

Page 29: ADAPT Floor Pro 2009/2010 Tutorial - ADAPT …€PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 6 FIGURE 1.2-1 1.2.2 Enter the Properties of Reinforcement

ADAPT‐PT 2010/RC 2010 to ADAPT‐Floor Pro 2009/2010 Strip Export Tutorial‐ 29  

If (a) there are any imported tendons from a previous ADAPT-PT execution for the same design strip, and (b) their status is not yet changed to “Consider” by you, the latest import of design data will overwrite the existing information. In other words, at any given stage, the tendons displayed in ADAPT-Floor Pro are either from the latest ADAPT-PT import, or are those you have viewed and determined to be retained and considered in your design. To validate a tendon, you can open its property window and view its particulars. A

powerful tool to view the tendon in elevation is the elevation viewer tool ( ) from the tendons property window.

References to be consulted with this manual:

1. ADAPT-Floor Pro 2009 – User Manual 2. ADAPT-Floor Pro 2009 – Getting Started Guide 3. ADAPT-PT 2010 – Getting Started Guide 4. ADAPT-PT 2010 – User Manual 5. ADAPT-PT 2010 – Examples & Verification Manual 6. ADAPT-RC 2010 – Getting Started Guide 7. ADAPT-RC 2010 – User Manual 8. ADAPT-RC 2010 – Theory, Examples & Verification Manual