Americans with Disabilities Act Transition Plans
Allan Henderson, AICP Ryan Phelps
Data Collection and Analysis of Public Facilities
16 E. 9th Street Anderson, IN 46016
LEGISLATION • Americans with Disabilities Act (ADA) of 1990
– Self-evaluation and Transition Plans
• ADA Title II – State and Local Government Programs and Services
• ADA Title III – Public Accommodations and Commercial Facilities
• Title II and III Relationship for collection – Possible for facilities to be indirectly affected by both titles
• i.e. Private within Public; Publically owned Mixed-use building; Joint Venture
STANDARDS COLLECTION ANALYSIS LEGISLATION
RESEARCHING THE STANDARDS • Americans with Disabilities Act Accessibility
Guidelines for Buildings and Facilities (ADAAG) • Proposed Accessibility Guidelines for Pedestrian
Facilities in the Public Right-of-Way (PROWAG) • Checklists
– Adaptive Environments Center, Inc. Barrier Free Environments, Inc. Checklist for Readily Achievable Barrier Removal
– Form 5.2 ADA Checklist
STANDARDS COLLECTION ANALYSIS LEGISLATION
RESEARCHING THE STANDARDS
5. ACCESS TO ALL DEPUTY REGISTRAR SERVICES. A. Does the accessible entrance provide direct access to the main
floor, lobby, or elevator? B. Are all public spaces on an accessible path of travel? C. Is the accessible route to all public spaces and services at least
36 inches wide (except for interior doors)? D. Do interior doors into public spaces have at least a 32-inch
clear opening? E. Is there at least 18 inches of clear wall space so that a person
using a wheelchair can get close enough to open the door? F. Can doors be opened without too much force? G. Are door handles 48 inches high or less and operable with a
closed fist? H. Are all interior thresholds, if any, level (less than ¼ inch high),
or beveled, up to ½ inch high?
Form 5.2 ADA Checklist
Form 5.2, Page 4 of 7 (2011)
No ___ Yes ___ No ___ Yes ___ No ___ Yes ___ No ___ Yes ___ No ___ Yes ___ No ___ Yes ___ No ___ Yes ___ No ___ Yes ___
STANDARDS COLLECTION ANALYSIS LEGISLATION
DATA COLLECTION METHODOLOGY • Categories
1. Accessible Entrance 2. Access to Services 3. Doors 4. Entrance 5. Floors 6. Lavatories 7. Clearance & Ramps
8. On-Street Parking 9. Parking 10. Ramp rails 11. Restrooms 12. Seats, Tables, Counters 13. Stalls 14. Visual Characteristics
COLLECTION ANALYSIS LEGISLATION STANDARDS
DATA COLLECTION METHODOLOGY
COLLECTION ANALYSIS LEGISLATION STANDARDS
Accessible Entrance vs. Access to Services
DATA COLLECTION METHODOLOGY
COLLECTION ANALYSIS LEGISLATION STANDARDS
Doors Lavatories Visual Characteristics
CATEGORY FIELD NAME FIELD ALIAS RESPONSE TYPE ANSWER ACCESSIBLE ENTRANCE
Facility FacilityName PathAcc Path from accessible parking w/o stairs Y/N FirmPath Path of travel stable, firm, and slip-resistant Y/N Path _48" Exclusive of curb cuts, path min 48" wide Note Width in inches Median_60" Medians or refuge islands min 60" wide Note Width in inches Cut_32" Curb cuts min 32" wide Note Width in inches Notes Note
ACCESS TO SERVICES
Facility FacilityName DirectAcc Accessible entrance direct access to main
floor, lobby, or elevator Y/N
PubSpace All public spaces on accessible path of travel Y/N AccRte_36" Accessible route min 36" wide Note Width in inches Notes Note
DATA COLLECTION METHODOLOGY
COLLECTION ANALYSIS LEGISLATION STANDARDS
MADISON COUNTY GOVERNMENT CENTER
COLLECTION ANALYSIS LEGISLATION STANDARDS
Base Map Exterior Doors Access Floors Seating Restrooms Visual Char.
COLLECTION ANALYSIS LEGISLATION STANDARDS
Exterior Doors Access Floors Seating Restrooms Visual Char. Base Map
MADISON COUNTY GOVERNMENT CENTER
1
2 3 4
COLLECTION ANALYSIS LEGISLATION STANDARDS
Exterior Doors Access Floors Seating Restrooms Visual Char. Base Map
MADISON COUNTY GOVERNMENT CENTER
1
2 3 4
COLLECTION ANALYSIS LEGISLATION STANDARDS
Exterior Doors Access Floors Seating Restrooms Visual Char. Base Map
MADISON COUNTY GOVERNMENT CENTER
1
2 3 4
COLLECTION ANALYSIS LEGISLATION STANDARDS
Exterior Doors Access Floors Seating Restrooms Visual Char. Base Map
MADISON COUNTY GOVERNMENT CENTER
1
2 3 4
COLLECTION ANALYSIS LEGISLATION STANDARDS
Exterior Doors Access Floors Seating Restrooms Visual Char. Base Map
MADISON COUNTY GOVERNMENT CENTER
1
2 3 4
COLLECTION ANALYSIS LEGISLATION STANDARDS
Base Map Exterior Doors Access Floors Seating Restrooms Visual Char.
MADISON COUNTY GOVERNMENT CENTER
1
2 3 4
COLLECTION ANALYSIS LEGISLATION STANDARDS
Base Map Exterior Doors Access Floors Seating Restrooms Visual Char.
MADISON COUNTY GOVERNMENT CENTER
ITEM/LOCATION STANDARD EXISTING CONDITION MODIFICATION ACCESS TO SERVICES (OFFICE 104)
Access to all public spaces from accessible path of travel, directly accessible, and min path width of 36”.
Directly accessible, with access to all public spaces, 53” wide path.
No modifications necessary at this time.
DATA ANALYSIS
ACCESS TO SERVICES: GOVERNMENT CENTER
Facility Government Center
Direct Accessibility? Yes
All public spaces acc from path of travel? Yes
Width of acc route? Min 36 53
Notes Office 104
ANALYSIS LEGISLATION STANDARDS COLLECTION
DATA ANALYSIS
ANALYSIS LEGISLATION STANDARDS COLLECTION
RESTROOMS: CONVENTION CENTER
Facility Convention Center
Customer restroom available? Yes
ADA Restroom available? Yes
ADA signage? Yes
Width of ADA doorway? Min 32 32
Height of door handle? Max 48 38
Operable with a closed fist? Yes
Door force < 5 lbs? Yes
Wheelchair maneuvering space in entry?
Yes
Path width to fixtures? Min 36 51
Notes
DATA ANALYSIS
ANALYSIS LEGISLATION STANDARDS COLLECTION
LAVATORIES: CONVENTION CENTER
Facility Convention Center
Clear Space 30x48? Yes
Depth of Sink? Max 19 17
Height of Sink Rim? Max 34 34
Height to bottom of Apron? Min 29 27
Operable with a closed fist? Yes
Soap/Dryer reach and usable? Yes
Height to bottom edge of Mirror? Max 40 42
Knee Depth? Mins 8 and 17 10
Notes
DATA ANALYSIS
ANALYSIS LEGISLATION STANDARDS COLLECTION
STALLS: CONVENTION CENTER
Facility Convention Center
Operable with a closed fist? Yes
Stall clearance 5x5? Yes
Installed grab bars? Yes
Height of toilet seat? 17-19 19
Notes
DATA ANALYSIS
ANALYSIS LEGISLATION STANDARDS COLLECTION
ITEM/LOCATION STANDARD EXISTING CONDITION MODIFICATION Restroom (Men’s) Accessible bathroom
available and marked with International Symbol of Accessibility, min 32” door opening, 48” max door handle, min 36” path to fixtures, max 5 lbs. door force, 5x5’ stall, grab bars, 17-19” toilet seat height. Sinks have clear space 30x48”, max depth 19”, max height 34”, min 29” apron, min 19” knee depth, max 48” high soap/dryer, max 40” high mirror.
Accessible restroom available and marked with International Symbol of Accessibility; 32” door width; door requires 5 lbs. force to open; door handle 38” high and operable with closed fist; 51” wide path to fixtures; 5x5’ clearance; grab bars installed; toilet seat 19” high. Sink clearance greater than 30x48”; 17” sink depth; 10” knee depth; 34” sink height; 27” sink apron; soap/dryer reachable; mirror 42” high
Increase sink apron clearance at least 2”; lower mirror at least 2”.
CONTACT INFORMATION
16 E. 9th Street Anderson, Indiana 46016 P 765.641.9482 F 765.641.9486 E [email protected]