Upload
juan-jose-vesga-rueda
View
20
Download
0
Embed Size (px)
Citation preview
D E S K - S E T - I N T E R C O M S
INSTALLATION AND SERVICE INSTRUCTIONS FOR
MODELS
AD-26T, AD-27T, AD-56T, and AD-57T
Address all communications and shipments to:
Electrical Products Division2645 Federal Signal DriveUniversity Park, IL 60466-3195
(888) 751-1500
INSTALLATION-AND-SERVICE-INSTRUCTIONS-FOR-ATKINSON-DYNAMICS-DESK-SET-INTERCOMS
SAFETY MESSAGE TO INSTALLERS,USERS, AND MAINTENANCE PERSONNEL
It is important to follow all instructions shipped with this product.This device is intended to be installed by a trained electrician who isthoroughly familiar with the National Electrical Code and will follow
NEC Guidelines as well as local codes.
The selection of the mounting location for the device, its controls, and therouting of the wiring are to be accomplished under the direction of thefacilities engineers and the safety engineer. In addition, listed below aresome other important safety instructions and precautions you shouldfollow:
• This is not a listed safety device and is not intended to be used assuch.
• Read and understand all instructions before installing or operating thisequipment.
• Disconnect power before connecting or doing any maintenance onthis intercom.
• All effective warning speakers produce loud sounds which may cause,in certain situations, permanent hearing loss. You should take appro-priate precautions, such as wearing hearing protection.
• After testing is complete, provide a copy of this instruction sheet to alloperating personnel.
• Establish a procedure to routinely check the intercom installation forintegrity and proper operation. Any maintenance must be performedby a trained electrician in accordance with NEC guidelines and localcodes.
Failure to follow all safety precautions and instructions may result inproperty damage, serious injury, or death to you or others.
A. GENERAL FEATURES.
The Atkinson Dynamics “T” model is a telephone style intercom withhandset that may be used as a desk set or as a wall mounted unit. Everymodel has an internal loud speaker with volume control which is alwaysmuted during the transmit function to prevent acoustical feedback. Thehandset on each desk set intercom is equipped with a microphone andsoft touch PTT (press-to-talk) button. A red LED on the front panel lights
-1-
up when the PTT button is pressed. An externally accessible volumecontrol for the handset earpiece is factory mounted on the back of thecase for easy operation. Nominal operating voltages for the desk setintercom include 12VDC, 24VDC, 120VAC, and 240VAC. The desk setintercoms are fully compatible with the Atkinson Dynamics wall mountmodels.
MODEL: AD-26T AD-56T AD-27T AD-57T
Supply Voltage 12 VDC 24VDC 120VAC, 240VAC,
50/60 Hz 50/60 Hz
Audio Power
Output (Max.) 1 Watt 1.4 Watts 1.4 Watts 1.3 Watts
Power
Consumption (Max.) 1.6 Watts 4.8 Watts 5 Watts 5 Watts
Operating Current
(Nominal) 130 mA 198 mA 42 mA 21 mA
Operating
Temperature -22° F to +167° F (-30° C to +75° C)
Shipping
Weight 4lb. 5oz. 4lb. 6.6oz. 4lb. 15oz. 4lb. 15oz.
Dimensions See Figure 1
Table 1
ADDITIONAL MODEL INFORMATION
Basic Options Function / Feature:
“C” Master unit
Enhanced Options
“-6” Separate talk and listen lines for selective switching
“-M22” Remote “monitor” on/off toggle switch
Table 2
MASTER UNITS:
“C” Models default to Master, or speaker mode. In Master mode, theunit broadcasts audio signals generated elsewhere in the intercomsystem. With the handset in the cradle, audio is broadcast through a
-2-
speaker mounted on the front panel of the desk set. Depressing thePTT (press-to-talk) button on the handset while speaking into thehandset microphone enables the user to broadcast to all other inter-coms in the system. Releasing the PTT button returns the unit toMaster mode. Figure 3 illustrates a Master/Slave intercom system.
SELECTIVE SWITCHING:
“-6” Models are equipped with separate talk and listen lines for selec-tive switching in a Master/Remote intercom system. A Master intercomcan select to talk to any one or more remotes through the use of acustomer supplied switch box. Figure 4 illustrates a Master/Remoteintercom system using a customer supplied switch box and toggleswitch.
REMOTE MONITOR SWITCH:
“-M22” Models are Master units equipped with a monitor on/off toggleswitch. Figure 5 illustrates an intercom system utilizing this model.When the monitor switch is “on,” it allows the remote intercom to serveas a “hands-free” microphone with transmission to the Master. Whenthe monitor switch is “off,” the remote intercom must press its talkswitch to broadcast to the Master. The remote unit will act as aspeaker and broadcast audio only when the PTT button on the Masteris depressed.
SURGE PROTECTION:
Metal Oxide Varistor (MOV) devices are used to protect the audio lines.The intercom must have Earth or Chassis Ground terminated to it toensure surge protection.
B. UNPACKING.
After unpacking the Atkinson Dynamics desk set intercom, examine it fordamage that may have occurred in transit. If the equipment has beendamaged, do not attempt to install or operate it, and file a claim immedi-ately with the carrier stating the extent of the damage. Carefully check allenvelopes, shipping labels and tags before removing or destroying them.
Before attempting to install the intercom, be sure that all parts listed inthe KIT CONTENTS LIST have been supplied.
-3-
C. KIT CONTENTS LIST.
Qty. Description Part Number
1 Instruction Manual 2561571B
D. MOUNTING.
CAUTION
The selection of the mounting location for the device, its controls, and therouting of the wiring are to be accomplished under the direction of the
facilities and the safety engineer.
The desk set console may be placed anywhere on a flat surface withinsix (6) feet of a power source. It may also be reconfigured to hang on awall or vertical surface. For wall mounting, remove the four (4) screwsfrom the corners which fasten the front PVC panel holder to the back ofthe case. Carefully lift the front PVC panel holder and rotate it 180degrees, watching so that the cables inside fit correctly. Reattach thepanel with the same screws so that when the unit is secured to the wall,the faceplate will slope outward at the bottom and the handset will be tothe left side on the front of the enclosure. Hardware for mounting theintercom to a surface is left up to the installer. Wherever the desk setintercom is mounted, it must be protected from rain or other waterpenetration that could cause severe damage to the internal circuits.Refer to figures 1 and 6 for dimensions of the desk set intercom andmounting hole locations (wall mount applications), respectively.
E. ELECTRICAL CONNECTIONS.
Plug each desk set intercom into a nearby power source. Connect theaudio inputs in parallel. Audio wires should be sized properly by alicensed installation electrician for your specified application. Refer tofigures 2 through 5 for typical connections and additional wiring informa-tion.
-4-
F. SERVICE.
1. GENERAL.
Federal Signal will service your equipment or provide technical assis-tance with any problems that cannot be handled locally.
Any units returned to Atkinson Dynamics for service, inspection, or repairmust be accompanied by a Return Material Authorization. This R.M.A.can be obtained only from the factory by calling (888) 751-1500. At thistime a brief explanation of the service requested, or the nature of themalfunction, should be given.
Address all communications and shipments to:
ATKINSON DYNAMICS
Service Department
2645 Federal Signal Drive
University Park, IL 60466-3195
2. REPLACEMENT PARTS.
DESCRIPTION PART NUMBER
Fuse, 1A (12/24VDC Models) K148A155A-01
Fuse, 1/2A (120/240VAC Models) K148A155A
Handset Assy., Black K8590283A
PCBA for Models:
AD-27T K2001910A
AD-26T K2001910A-02
AD-57T K2001910A-01
AD-56T K2001910A-03
AD-27T-6 K2001910A-6
AD-57T-6 K2001910A-01-6
AD-26T-6 K2001910A-02-6
AD-27CT K2001910A-CT
AD-26CT K2001910A-02-CT
AD-27CT-M22 K2001910A-CT-M22
-5-
7.63
"
8.63
"
4.45
"
8.00
"
4.31
"
290A
3972
-01
1
-6-
BLK
TO O
TH
ER
INT
ER
CO
MS
WH
T
AU
DIO
CO
MM
ON
290A
3972
-02
RE
MO
TE
C
4
6
5
SE
E P
OW
ER
CO
NN
EC
TIO
NS
*B
LKW
HT
GR
N*
BLK
WH
TRE
MO
TE
BR
EM
OT
E A
4
6
5
SE
E P
OW
ER
CO
NN
EC
TIO
NS
*B
LKW
HT
GR
N*BLK
WH
TG
RN
*2
31
PO
WE
R C
ON
NE
CT
ION
S:
BLK
+D
C-P
OW
ER
12/2
4V M
odel
sH
OT
120/
240V
Mod
els
WH
TC
omm
on12
/24V
Mod
els
Neu
tral
120/
240V
Mod
els
GR
NE
arth
Gro
und
120/
240V
Mod
els
only
PO
WE
RR
EM
OT
E-A
RE
MO
TE
S B
-&-C
12V
DC
AD
-26T
AD
-26
120V
50/
60H
zA
D-2
7TA
D-2
724
4VD
CA
D-5
6TA
D-5
624
0V 5
0/60
Hz
AD
-57T
AD
-57
NO
TE
S:
1.D
esk
Set
spe
aker
(m
icro
phon
e is
mou
nted
on
hand
set)
2.D
esk
Set
spe
aker
vol
ume
cont
rol
3.H
ands
et e
arpi
ece
volu
me
cont
rol
(mou
nted
on
back
of c
ase)
4.S
peak
er/M
icro
phon
e5.
Off/
On/
Spe
aker
vol
ume
cont
rol
6.Ta
lk/L
iste
n sw
itch
Op
erat
ing
Pri
nci
ple
:1.
Whe
n on
e in
terc
om t
alks
, al
l of
the
inte
rcom
s w
ill h
ear.
2.F
or R
emot
es B
or
C t
o ta
lk t
o ot
her
stat
ions
, pr
ess
the
talk
/lis
ten
switc
h an
d sp
eak
into
the
spe
aker
/mic
roph
one.
Rel
ease
talk
sw
itch
to li
sten
.3.
For
Rem
ote
A t
o ta
lk t
o ot
her
stat
ions
, pr
ess
PT
T-bu
tton
onha
ndse
t an
d ta
lk in
to h
ands
et m
icro
phon
e.
2
-7-
BLK
TO O
TH
ER
INT
ER
CO
MS
GR
N
CO
NT
RO
L
AU
DIO
290A
3972
-03
SLA
VE
4 5
SE
E P
OW
ER
CO
NN
EC
TIO
NS
*B
LKW
HT
GR
N*
BLK
GR
NMA
ST
ER
B
MA
ST
ER
DE
SK
SE
T
4
6
57
SE
E P
OW
ER
CO
NN
EC
TIO
NS
*B
LKW
HT
GR
N*
WH
TC
OM
MO
NW
HT
BLK
GR
NMA
ST
ER
A
4
65
SE
E P
OW
ER
CO
NN
EC
TIO
NS
*B
LKW
HT
GR
N*
WH
T
BLK
GR
N
WH
T
8
BLK
WH
TG
RN
*
3
2
1
NO
TE
S:
1.D
esk
Set
spe
aker
(m
icro
phon
e is
mou
nted
on
hand
set)
2.D
esk
Set
spe
aker
vol
ume
cont
rol
3.H
ands
et e
arpi
ece
volu
me
cont
rol (
mou
nted
on
back
of
case
)4.
Spe
aker
/Mic
roph
one
5.O
ff/O
n/S
peak
er v
olum
e co
ntro
l6.
Talk
Sw
itch
7.#1
3714
4 ha
nd-h
eld,
noi
se c
ance
lling
mic
roph
one
8.3-
cond
ucto
r/16
-22
gaug
e ca
ble.
Use
shi
elde
d ca
ble
inel
ectr
ical
ly n
oisy
are
as. G
roun
d on
e en
d of
the
shie
ld.
Do
not
conn
ect
shie
ld t
o ch
assi
s of
AC
-pow
ered
inte
rcom
.
DE
SK
SE
TP
OW
ER
MA
ST
ER
MA
ST
ER
AM
AS
TE
R B
SL
AV
E12
VD
CA
D-2
6CT
AD
-26C
AD
-26C
-7A
D-2
6D12
0V 5
0/60
Hz
AD
-27C
TA
D-2
7CA
D-2
7C-7
AD
-27D
Op
erat
ing
Pri
nci
ple
:1.
Mas
ter
norm
ally
list
ens
to S
lave
(S
lave
in h
ands
-fre
e m
ode)
.2.
Whe
n an
y M
aste
r pr
esse
s ta
lk b
utto
n, S
lave
list
ens.
3.W
hen
ther
e is
mor
e th
an o
ne S
lave
, S
lave
s w
ill t
rans
mit
toM
aste
r(s)
at
the
sam
e tim
e.
PO
WE
R C
ON
NE
CT
ION
S:
BLK
+D
C-P
OW
ER
12/2
4V M
odel
sH
OT
120/
240V
Mod
els
WH
TC
omm
on12
/24V
Mod
els
Neu
tral
120/
240V
Mod
els
GR
NE
arth
Gro
und
120/
240V
Mod
els
only
Bef
ore
inst
allin
g r
emo
te in
terc
om
s, p
reca
uti
on
sho
uld
be
take
n t
o p
reve
nt
feed
bac
k b
etw
een
two
or
mo
re r
emo
tes
in c
lose
pro
xim
ity
and
aco
ust
ical
ly r
efle
ctiv
e ar
eas.
3
-8-
290A
3972
-04
RE
MO
TE
RB
MA
ST
ER
DE
SK
SE
T
MA
ST
ER
WA
LL M
OU
NT
INT
ER
CO
M
4 5
SE
E P
OW
ER
CO
NN
EC
TIO
NS
BLK
WH
TG
RN
*
*
*
****
RE
MO
TE
RA
4
7
6
3
5
BLK
WH
TG
RN
BLK
WH
TG
RN
RE
MO
TE
RC
DE
SK
SE
T
BLK
WH
TG
RN
TO O
TH
ER
RE
MO
TE
S
4
65
BLK
WH
TG
RN
*
*
*
WH
T
47 Ω
GR
N
RE
D
BLK
BLK
RE
D
GR
N
WH
T
TALK
CO
M.
TALK
LIS
TE
N
LIS
TE
N C
OM
.
TALK
CO
M.
TALK
LIS
TE
N
LIS
TE
N C
OM
.
TALK
CO
M.
TALK
LIS
TE
N
LIS
TE
N C
OM
.
TALK
CO
M.
TALK
LIS
TE
N
LIS
TE
N C
OM
.
BLK
RE
D
GR
N
WH
T
BLK
RE
D
RC
RB
RA
GR
N
WH
T
47 Ω 47 Ω
2
3
2
88
1
1
6
NO
TE
S:
1.D
esk
Set
spe
aker
(m
icro
phon
e is
mou
nted
on
hand
set)
2.D
esk
Set
spe
aker
vol
ume
cont
rol
3.H
ands
et e
arpi
ece
volu
me
cont
rol (
mou
nted
on
back
of
case
)4.
Spe
aker
/Mic
roph
one
5/O
ff/O
n/S
peak
er v
olum
e co
ntro
l6.
Talk
/Lis
ten
switc
h7.
Mas
ter
switc
h bo
x —
cus
tom
er s
uppl
ied
PO
WE
R C
ON
NE
CT
ION
S:
BLK
+D
C-P
OW
ER
12/2
4V M
odel
sH
OT
120/
240V
Mod
els
WH
TC
omm
on12
/24V
Mod
els
Neu
tral
120/
240V
Mod
els
PO
WE
RR
EM
OT
ES
-RA
-&-R
B*
RE
MO
TE
-RC
*12
VD
CA
D-2
6-6
AD
-26T
-612
0V 5
0/60
Hz
AD
-27-
6A
D-2
7T-6
240V
50/
60H
zA
D-5
7-6
AD
-57T
-6
** R
efer
to
rem
ote
mod
el n
umbe
r as
an
exam
ple
for
Mas
ter.
Op
erat
ing
Pri
nci
ple
:1.
Mas
ter
can
sele
ct (
via
mas
ter
switc
h bo
x) t
o ta
lk t
o an
y on
e or
mor
ere
mot
es.
2.A
ny r
emot
e ca
n in
itiat
e a
call
to M
aste
r re
gard
less
of
sele
ctor
sw
itch
bein
gon
or
off.
Rem
ote
mus
t sp
ecify
its
loca
tion.
Rem
otes
can
not
talk
to
othe
rre
mot
es.
3.To
tal
k in
to in
terc
om,
pres
s ta
lk s
witc
h an
d sp
eak
into
spe
aker
/m
icro
phon
e.-R
elea
se t
alk
switc
h to
list
en.
4.Fo
r M
aste
r to
talk
to r
emot
e, s
elec
t des
ired
rem
ote
via
sele
ctor
sw
itch
, pre
ssta
lk s
witc
h on
han
dset
mic
roph
one
and
talk
into
han
dset
mic
roph
one.
4
-9-
GR
N
WH
T
BLK
GR
N
WH
T
BLK
AU
DIO
CO
MM
ON
CO
NT
RO
L
290A
3972
-05
SLA
VE
MA
ST
ER
DE
SK
SE
T4
3
6
5
SE
E P
OW
ER
CO
NN
EC
TIO
NS
*B
LKW
HT
GR
N
BLK
WH
TG
RN
*
*
8
27
1
Po
wer
Co
nn
ecti
on
s:B
LKH
OT
120/
240V
Mod
els
WH
TN
eutr
al12
0/24
0V M
odel
sG
RN
Ear
th G
roun
d12
0/24
0V M
odel
s on
ly*H
avin
g m
ore
than
one
Mas
ter
is n
ot r
ecom
men
ded
for
this
sys
tem
.
OP
ER
AT
ING
-PR
INC
IPL
E:
1.W
hen
mon
itor
switc
h is
“O
N”,
Mas
ter
norm
ally
list
ens
to S
lave
.(S
lave
is h
ands
-fre
e.)
2.M
aste
r m
ust
pres
s Ta
lk s
witc
h to
tal
k to
Sla
ve.
3.W
hen
Mon
itor
switc
h is
“O
FF
”, S
lave
mus
t pr
ess
Talk
sw
itch
tota
lk t
o M
aste
r.
NO
TE
S:
1.D
esk
Set
spe
aker
(m
icro
phon
e is
mou
nted
on
hand
set)
2.D
esk
Set
spe
aker
vol
ume
cont
rol
3.H
ands
et e
arpi
ece
volu
me
cont
rol (
mou
nted
on
back
of
case
)4.
Spe
aker
/Mic
roph
one
5.O
ff/O
n/S
peak
er v
olum
e co
ntro
l6.
Talk
sw
itch
7.M
onito
r on
/off
switc
h8.
Use
shi
elde
d ca
ble
in e
lect
rical
ly n
oisy
are
a. G
roun
don
e en
d of
shi
eld.
Do
not c
onne
ct s
hiel
d to
cha
ssis
of
AC
-pow
ered
inte
rcom
.
Pow
erM
aste
rS
lave
120V
50/
60H
zA
D-2
7CT-
M22
AD
-27-
2W3
5
-10-
290A3972-06
1
WALL-MOUNTING-CONFIGURATION
NOTES:
1. Two mounting slots provided for surface mount installations:slot will accept a #10 screw (supplied by installer)
6
2561571BREV. B 202Printed in U.S.A.