TECHNICAL INFORMATION
ACTUATOR WIRING
DIAGRAMS
800-288-1112 www.kzvalve.com 1
WIRING DIAGRAM DIRECTORY
EH3 Description P/N Examples Wire Code Page
On/Off, 12VDC, 3-Wire/3-Pin, SPST On/Off, 12VDC, 3-Wire/4-Pin On/Off, 12VDC, 4-Wire/4-Pin, Switched (+) or (-) On/Off, 12VDC, 4-Wire/4-Pin with Feedback On/Off, 12/24VDC, 3-Wire/3-Pin, SPST On/Off, 24VAC 12/24VDC, 3-Wire/4-Pin Regulating, 12VDC, 2-Wire/2-Pin, DPDT Regulating, 12VDC, 4-Wire/4-Pin, SPDT Analog 0-5V / 0-10V Positioning Control 4 ~ 20mA Positioning Control F Option–2 Wet Limit Switches (FB @ open/close) E Option–2 Dry Limit Switches (FB @ open/close)
Diagram 1. Diagram 2. Diagram 3. Diagram 4. Diagram 5. Diagram 6. Diagram 7. Diagram 8. Diagram 9. Diagram 10. Diagram 11. Diagram 12. Diagram 13.
2 2 2 3 3 3 4 4 4 5 5 6 6
60A 60B 55 60
60AD 66
50K 62
421/425 41
42mA F E
EH2 Description P/N Examples Wire Code Page Diagram 1. Diagram 2. Diagram 3. Diagram 4. Diagram 5. Diagram 6. Diagram 7. Diagram 8. Diagram 9. Diagram 10. Diagram 11. Diagram 11a. Diagram 12. Diagram 13.
On/Off, 12VDC, 3-Wire/3-Pin, SPST On/Off, 12VDC, 3-Wire/4-Pin On/Off, 12VDC, 4-Wire/4-Pin, Switched (+) or (-) On/Off, 12VDC, 4-Wire/4-Pin with Feedback On/Off, 12/24VDC, 3-Wire/3-Pin, SPST On/Off, 24VAC 12/24VDC, 3-Wire/4-Pin Regulating, 12VDC, 2-Wire/2-Pin, DPDT Regulating, 12VDC, 4-Wire/4-Pin, SPDT Analog 0-5V / 0-10V Positioning Control 4 ~ 20mA Positioning Control SERVICE PART ONLY (4 ~ 20mA) F Option–2 Wet Limit Switches (FB @ open/close) E Option–2 Dry Limit Switches (FB @ open/close)
60A 60B 55 60
60AD 66
50K 62
421/425 41
42mA 42 F E
7 7 7 8 8 8 9 9 9
10 10 10 11 11
EH5 Description P/N Examples Wire Code Page Diagram 1. Diagram 4. Diagram 5. Diagram 6. Diagram 8. Diagram 9. Diagram 11. Diagram 12. Diagram 13.
On/Off, 12VDC, 3-Wire/3-Pin, SPST On/Off, 12VDC, 4-Wire/4-Pin, with Feedback On/Off, 12/24VDC, 3-Wire/3-Pin, SPST On/Off, 24VAC, 12/24VDC 3-Wire/4-Pin Regulating, 12VDC, 4-Wire/4-Pin, SPDT Analog 0-5V / 0-10V 4 ~ 20mA Positioning Control F Option–2 Wet Limit Switches (FB @ open/close) E Option–2 Dry Limit Switches (FB @ open/close)
60A 60
60AD 66 62
421/425 42mA
F E
12 12 12 13 13 13 14 14 15
10D20-P01 10D20-B01 000-55-M 1ADM0-P01 10E2S-P01 or 60F20-P01 10ANS-B01 000-50K-M 20D20-P01 B0EPS-D01 or C0ENS-D01 000-41-P or K4DP0-P02 A0DN0-D01 12D20-D01 or 22DN0-D01 13D20-D01 or 13E2S-D01
10DW0-P01 10DW0-B01 000-55-Z 1ADY0-P01 10EWS-P01 or 60FW0-P01 10AWS-B01 000-50K-W or K0HU0-P01 20DY0-P01 B0EWS-D01 or C0EWS-D01 000-41-Y or K4HV0-P01 A0DW0-D01 or A0EWS-D01 000-42-W 12AW0-D01 or 22EWS-D01 13AW0-D01 or 13EWS-D01
10D50-PB1 1AD50-DB1 10E5S-PB1 10A53-DB1 or 10A5S-DB1 20D50-PB1 B0E5S-D01 or C0A5S-DB1 A0D5S-D01 12D50-DB1 or 22D50-DB1 13D50-DB1 or 23E5S-DB1
WARNING: Wiring direct to battery not recommended.
Install actuator after ignition switch, or master power switch
800-288-1112 www.kzvalve.com 2
COMPACT ACTUATOR MODEL “EH3”
WARNING: Wiring direct to battery not recommended.
Install actuator after ignition switch, or master power switch
800-288-1112 www.kzvalve.com 3
800-288-1112 www.kzvalve.com 4
800-288-1112 www.kzvalve.com 5
800-288-1112 www.kzvalve.com 6
800-288-1112 www.kzvalve.com 7
MID-SIZE ACTUATOR MODEL “EH2”
WARNING: Wiring direct to battery not recommended.
Install actuator after ignition switch, or master power switch
800-288-1112 www.kzvalve.com 8
800-288-1112 www.kzvalve.com 9
800-288-1112 www.kzvalve.com 10
800-288-1112 www.kzvalve.com 11
800-288-1112 www.kzvalve.com 12
HEAVY DUTY ACTUATOR MODEL “EH5”
WARNING: Wiring direct to battery not recommended.
Install actuator after ignition switch, or master power switch
800-288-1112 www.kzvalve.com 13
800-288-1112 www.kzvalve.com 14
800-288-1112 www.kzvalve.com 15