    MUNICIPAL, DRINKING WATER CLARIFICATION

    UlphaVeolia Water Solutions & Technologies

    UNITED KINGDOM

    ACTIFLO: sand ballasted clarification from municipal water treatment

    PROJECT OVERVIEW

    Veolia Water Solutions & Technologies provided the processdesign, construction, installation, testing and commissioningof 3 Actiflo High Rate Clarifiers and 2 Multiflo forbackwash water recovery. The project included sand storage,make up, transfer and recovery system, polymer make upand dosing system, MCC and software for the abovesystems.

    The purpose of the project is to prevent Cryptosporidium,

    reduce the levels of manganese in the final water andimprove the disinfection system by reducing TOC content.

    View of Ulpha WTW

    PILOT TRIALS

    In order to provide confidenceto the potential Client, VWSinstalled and operated for a 10months period in 1999 - 2000 a200 m

    3/hr pilot plant at

    Watchgate WTW. The pilotplant provided data for Actifloperformance and subsequentsand filtration. Based on these

    results UU specified Actiflo forclarification at Ulpha WTW.

    THE CLIENT

    United Utilities are the 2nd

    largest water company inEngland / Wales. They areresponsible for an area in thenorth west of the UK, whichincludes major Cities such asManchester and Liverpool.

    Area served: 15,378km2Population served: 6.6m

    THE WORKS

    Ulpha WTW is located nearMillom in Cumbria in the LakeDistrict National Park and itsupplies 30,000 people in thegreater Barrow-in-Furness area.

    THE ACTIFLO PROCESS

    Actiflo

    is a very compact process that utilises microsand asa seed for floc formation. The microsand provides surfacearea that enhances flocculation and also acts as a ballast orweight.

    The resulting microsand ballasted floc display unique settlingcharacteristics, which allow for clarifier designs with highoverflow rates and short retention times. These designs

    result in system footprints that are between 5 times smallerthan classic lamella clarifier or dissolved air flottation and upto 20 times smaller than conventional clarification systems ofsimilar capacity, with an ability to start up from a standbymode of operation to a steady state operating mode withinminutes.

  • 8/3/2019 Act if Lo

    2/2

    THE CONTRACTA design and constructioncontract for United UtilitiesFramework supplies, HMBAoperating under ECC Option Ccontract conditions.

    Value: 4.7mProgramme: 110 weeksCompletion: March 2005

    Actiflo Plant during construction

    FLOW DATA(Raw Water Abstraction)

    Minimum flow : 7012 m3/day

    Average flow : 14024 m3/day

    Maximum flow : 22037 m3/day

    ACTIFLO CLARIFIERCHARACTERISTICS

    Number stream 3

    Lamella surface areaper stream 46 m

    2

    Maximum rise rate 42 m/h

    MULTIFLO CLARIFIERCHARACTERISTICS

    Number stream 2

    Lamella surface areaper stream 6.2 m

    2

    Maximum rise rate 7.6 m/h

    CONSTRUCTION

    United Utilities awarded theconstruction contract to VWSwere sub-contractors to UnitedUtilities Framework suppliers,HMBA operating under ECCOption C contract conditions.

    DESCRIPTION OF ACTIFLO

    PROCESS PLANT

    Influent Criteria (from Impounding Reservoir) :

    Min Av MaxTurbidity 0.2 0.73 480 NTUT.Colour 2 6.6 20 mg/l Pt/CoMn 0 0.02 0.44 mg/l

    Treated Effluent Consents : (95%ile spot samples)

    Turbidity < 2 NTUT.Colour < 10 mg/l Pt/Co

    ULPHA WATER TREATMENT WORKSPROCESS FLOW DIAGRAM