Upload
sreekanth-raveendran
View
42
Download
3
Embed Size (px)
DESCRIPTION
Accessories for Tesys Breakers
Citation preview
�
GV2 AK00GV1 L3
GV AD
GV AM11
GV AM11
GV AN
GV AN
GV2 P
GV2 ME
GV AX
GV AU
GV AS
GV AE1
GV AE1
GV AE11, GV AE20
GV2 L
GV2 LE
�451�-EN.inddversion: 15.1
1
2
3
4
5
6
7
8
9
10
�
Contact blocksDescription Mounting Maximum
numberType of contacts
Sold in lots of
Unit reference
Weightkg
Instantaneous auxiliary contacts
Front (1) 1 N/O or N/C (2) 10 GV AE1 0.015N/O + N/C 10 GV AE11 0.0�0N/O + N/O 10 GV AE20 0.0�0
Side (LH)
� N/O + N/C 1 GV AN11 0.050N/O + N/O 1 GV AN20 0.050
Fault signalling contact + instantaneous auxiliary contact
Side (3) (LH)
1 N/O (fault) + N/O 1 GV AD1010 0.055+ N/C 1 GV AD1001 0.055
N/C (fault) + N/O 1 GV AD0110 0.055+ N/C 1 GV AD0101 0.055
Short-circuit signalling contact
Side (LH)
1 C/O common point 1 GV AM11 0.045
Electric tripsMounting Voltage Reference Weight
kgUndervoltage or shunt trips (4)
Side (1 block on RH side of circuit-breaker)
�4 V 50 Hz GV Ap025 0.10560 Hz GV Ap026 0.105
48 V 50 Hz GV Ap055 0.10560 Hz GV Ap056 0.105
100 V 50 Hz GV Ap107 0.105100…110 V 60 Hz GV Ap107 0.105110…115 V 50 Hz GV Ap115 0.105
60 Hz GV Ap116 0.1051�0…1�7 V 50 Hz GV Ap125 0.1051�7 V 60 Hz GV Ap115 0.105�00 V 50 Hz GV Ap207 0.105�00…��0 V 60 Hz GV Ap207 0.105��0…�40 V 50 Hz GV Ap225 0.105
60 Hz GV Ap226 0.105�80…400 V 50 Hz GV Ap385 0.105
60 Hz GV Ap386 0.105415…440 V 50 Hz GV Ap415 0.105415 V 60 Hz GV Ap416 0.105440 V 60 Hz GV Ap385 0.105480 V 60 Hz GV Ap415 0.105500 V 50 Hz GV Ap505 0.105600 V 60 Hz GV Ap505 0.105
Undervoltage trip, INRS (can only be mounted on GV2 ME) Safety device for dangerous machines conforming to INRS and VDE 0113
Side (1 block on RH side of circuit-breaker GV� ME)
110…115 V 50 Hz GV AX115 0.11060 Hz GV AX116 0.110
1�7 V 60 Hz GV AX115 0.110��0…�40 V 50 Hz GV AX225 0.110
60 Hz GV AX226 0.110�80…400 V 50 Hz GV AX385 0.110
60 Hz GV AX386 0.110415…440 V 50 Hz GV AX415 0.110440 V 60 Hz GV AX385 0.110
Add-on contact blocksDescription Mounting Maximum
numberReference Weight
kgVisible isolation block (5) Front (1) 1 GV2 AK00 0.150Limiters At top
(GV� ME and GV� P)1 GV1 L3 0.1�0
Independent 1 LA9 LB920 0.��0
(1) Mounting of a GV AE contact block or a GV2 AK00 visible isolation block on GV2 P and GV2 L.(2) Choice of N/C or N/O contact operation, depending on which way round the reversible block is mounted.(3) The GV AD is always mounted next to the circuit-breaker.(4) To order an undervoltage trip: replace the dot (p) in the reference with a U, example: GV AU025.
To order a shunt trip: replace the dot (p) in the reference with an S, example: GV AS025.(5) Visible isolation of the 3 poles upstream of circuit-breaker GV2 P and GV2 L.
Visible isolation block GV2 AK00 cannot be used with motor circuit-breakers GV2 P32 and GV2 L32 (Ith max = 25 A).
LA9 LB920LA9 LB920
Characteristics:pages �451�/� to �451�/7
Dimensions, schemes:pages �45�8/� to �45�7/7
Characteristics:pages �451�/� to �451�/7
Dimensions, schemes:pages �45�8/� to �45�7/7
Characteristics:pages �451�/� to �451�/7
Dimensions, schemes:pages �45�8/� to �45�7/7
Characteristics:pages �451�/� to �451�/7
Dimensions, schemes:pages �45�8/� to �45�7/7
References TeSys protection componentsThermal-magnetic and magnetic motor circuit-breakers GV� with screw clamp connectionsAdd-on blocks and accessories
�451�-EN.indd version: 15.1
4 �451�-EN.inddversion: 15.1
1
2
3
4
5
6
7
8
9
10
5
AccessoriesDescription Application Sold in
lots of Unit reference
Weightkg
Adapter plates For mounting a GV� ME or GV� LE by screw fixing
10 GV2 AF02 0.0�1
For mounting a GV� ME or GV� P and contactor LC1 D09…D�8 with front faces aligned
1 LAD 311 0.040
Height compensation plate 7,5 mm 10 GV1 F03 0.00�Combination blocks Between GV� and contactor LC1 K or LP1 K 10 GV2 AF01 0.0�0
Between GV� and contactor LC1 D09…D�8 10 GV2 AF3 0.016Between GV� mounted on LAD �11 and contactor LC1 D09…D�8
10 GV2 AF4 0.016
Motor starter adapter plate With �-pole connection for mounting a GV� and a contactor LC1 D09…D�5
1 GK2 AF01 0.1�0
Description Application Pitch Reference Weightmm kg
Sets of 3-pole 63 A busbars
� tap-offs 45 GV2 G245 0.0�654 GV2 G254 0.0�87� GV2 G272 0.04�
� tap-offs 45 GV2 G345 0.05854 GV2 G354 0.060
4 tap-offs 45 GV2 G445 0.07754 GV2 G454 0.0857� GV2 G472 0.094
5 tap-offs 54 GV2 G554 0.100
Description Application Sold in lots of
Unit reference
Weightkg
Protective end cover For unused busbar outlets 5 GV1 G10 0.005
Terminal block for supply to one or more GV� G busbar sets
Connection from the top 1 GV1 G09 0.040Can be fitted with current limiter GV1 L� (GV� ME and GV� P)
1 GV2 G05 0.115
Cover for terminal block For mounting in modular panels 10 LA9 E07 0.005
Flexible 3-pole connection for connecting a GV� to a contactor LC1-D09…D�5
Centre distance between mounting rails: 100…1�0 mm
10 GV1 G02 0.01�
Set of connections upstream/downstream
For connecting GV� ME to a printed circuit board 10 GV2 GA01 0.045
“Large Spacing” adapter UL 508 type E
For GV� PppH7 (except �� A) 1 GV2 GH7 0.040
Clip-in marker holders (supplied with each circuit-breaker)
For GV� P, GV� L, GV� LE and GV� RT (8 x �� mm)
100 LA9 D92 0.001
References TeSys protection componentsThermal-magnetic and magnetic motor circuit-breakers GV� with screw clamp connectionsAccessories
�451�-EN.indd version: 15.1
6
1
5
3
2
4
6
7
Extended Rotary HandleAllows a circuit-breaker or a starter-controller installed in back of an enclosure to be operated from the front of the enclosure.A rotary handle can be black or red/yellow, IP54 or IP65. It includes a function for locking the circuit breaker or the starter in the O (Off) or I (On) position (depending of the type of rotary handle) by means of up to � padlocks with a shank diameter of 4 to 8 mm. The extended shaft must be adjusted to use in different size enclosures. The IP54 rotary handle is fixed with a nut (Ø ��) to make easier the assembling. The new Laser Square tool brings the accurency to align the circuit breaker and the rotary handle.
Padlockable external operators for GV2P and GV2LDescription
1 Kit handle + mounting system2 Universal handle3 Shaft4 Bracket5 Shaft support plate for deep enclosure6 Retrofit accessory7 Laser Square accessory
Kit handle + mounting systemDescription Item Reference Weight
kgFor GV2 P/L Black handle, front plate, with trip status, IP 54 1 GV2 APN01 0.�00
Red handle, front plate, with trip status, IP 54 1 GV2 APN02 0.�00Red handle, front plate, without trip status, IP 65 1 GV2 APN04 0.�00
For GV2 LE Padlocking in “On” and “Off” position Black handle, blue front plate, IP 54
- GV2 AP03 0.�80
Universal handleFor GV2 P/L Black handle, IP 54 2 GV APB54 0.140
Red handle, IP 54 2 GV APR54 0.140Red handle, IP 65 2 GV APR65 0.140
ShaftFor GV2 P/L L = �15 mm 3 GV APA1 0.110
BracketFor GV2 P/L 4 GV APH02 0.�00
Shaft support plate for deep enclosureFor GV2 P/L Depth u �50 mm 5 GV APK11 0.0�0
Retrofit accessoryFor GV2 P/L 6 GV APP1 0.100
Laser Square accessoryFor GV2 P/L 7 GV APL01 0.160
Sticker Sold in lots ofWarning label For French 10 - GV APSFR
For English 10 - GV APSENFor German 10 - GV APSDEFor Spanish 10 - GV APSESFor Chinese 10 - GV APSCNFor Portuguese 10 - GV APSPTFor Russian 10 - GV APSRUFor Italian 10 - GV APSIT
Padlocking deviceDescription Reference Weight
kgFor all GV2 device
For use with up to 4 padlocks, Ø 6 mm shank max. (padlocks not included)
GV2 V03 0.09�
Dimensions:pages �45�8/5, �45�7/� and �45�7/6
References TeSys protection componentsThermal-magnetic and magnetic motor circuit-breakers GV� with screw clamp connections
�451�-EN.inddversion: 15.1
1
2
3
4
5
6
7
8
9
10
7 �451�-EN.indd version: 15.1
8
GV AM11
GV AM11
GV AE1
GV AE1
GV AE11, GV AE20,
GV3 L
GV3 P
GV3 G364
GV AE113, GV AE203, GV AED 1013, GV AED 0113
GV AED 101, GV AED 011
GV2 V03
GV3 G264
GV3 APN02
�451�-EN.inddversion: 15.1
1
2
3
4
5
6
7
8
9
10
9
Contact blocksDescription Mounting Maximum
numberType of contacts
Sold in lots of
Unit reference
Weightkg
Instantaneous auxiliary contacts
Front 1 N/O or N/C (1) 10 GV AE1 0.015N/O + N/C 10 GV AE11 (2) 0.0�0N/O + N/O 10 GV AE20 (2) 0.0�0
Side (LH)
� N/O + N/C 1 GV AN11 (2) 0.050N/O + N/O 1 GV AN20 (2) 0.050
Fault signalling contact + instantaneous auxiliary contact
Front 1 N/O (fault) + N/O 1 GV AED101 (2) 0.0�0N/O (fault) + N/C 1 GV AED011 (2) 0.0�0
Side (3) (LH)
1 N/O (fault) + N/O 1 GV AD1010 0.055+ N/C 1 GV AD1001 0.055
N/C (fault) + N/O 1 GV AD0110 0.055+ N/C 1 GV AD0101 0.055
Short-circuit signalling contact Side (LH) 1 C/O common point 1 GV AM11 0.045
Electric trips - undervotlage or shunt (4)Mounting Voltage Reference Weight
kgSide (1 block on RH side of circuit-breaker)
�4 V 50 Hz GV Ap025 0.10560 Hz GV Ap026 0.105
48 V 50 Hz GV Ap055 0.10560 Hz GV Ap056 0.105
100 50 Hz GV Ap107 0.105100…110 V 60 Hz GV Ap107 0.105110…115 V 50 Hz GV Ap115 0.105
60 Hz GV Ap116 0.1051�0…1�7 V 50 Hz GV Ap125 0.1051�7 V 60 Hz GV Ap115 0.105�00 V 50 Hz GV Ap207 0.105�00…��0 V 60 Hz GV Ap207 0.105��0…�40 V 50 Hz GV Ap225 0.105
60 Hz GV Ap226 0.105�80…400 V 50 Hz GV Ap385 0.105
60 Hz GV Ap386 0.105415…440 V 50 Hz GV Ap415 0.105415 V 60 Hz GV Ap416 0.105440 V 60 Hz GV Ap385 0.105480 V 60 Hz GV Ap415 0.105500 V 50 Hz GV Ap505 0.105600 V 60 Hz GV Ap505 0.105
AccessoriesDescription Reference Weight
kgSets of 3-pole 115 A busbarsPitch: 64 mm
� tap-off GV� Ppp and GV� Lpp GV3 G264 0.150� tap-off GV� Ppp and GV� Lpp GV3 G364 0.�50
Cover “Large Spacing” UL 508 type E(Only one cover required on supply side)
GV� Ppp GV3 G66 0.0�0
IP 20 cover (Two covers required per breaker)
GV� Ppp6 and GV� Lpp6 LAD 96570 0.0�1
IP 20 cover for use when mounted with circuit-breakers
GV� Ppp6 and GV� Lpp6 LAD 96575 0.010
Size 4 Allen key, insulated, 1000 V GV� Ppp and GV� Lpp LAD ALLEN4 (5) 0.0�6Padlocking device for use with up to 4 padlocks (not supplied) Ø 6 mm shank max.
GV� Ppp and GV� LppGV� Ppp6 and GV� Lpp6
GV2 V03 0.09�
Retrofit plate for screw fixing
Replacement of GV� ME with GV� Ppp or GV� Ppp
LAD 7X3 0.150
(1) Choice of N/C or N/O contact operation, depending on which way round the reversible block is mounted.(2) Contact blocks available in version with spring terminal connections. Add a figure 3 at the end of the references selected above.
Example: GV AED101 becomes GV AED1013.(3) The GV ADpp is always mounted next to the circuit-breaker.(4) To order an undervoltage trip: replace the dot (p) in the reference with a U, example: GV AU025.
To order a shunt trip: replace the dot (p) in the reference with an S, example: GV AS025.(5) Sold in lots of 5.
References TeSys protection componentsThermal-magnetic motor circuit-breakers GV� P and GV� LAdd-on blocks and accessories
GV3 G66
LAD 96570
LAD 96575
LAD 7X3
�451�-EN.indd version: 15.1
10
1
5
3 2
4
6
7
Extended Rotary HandleAllows a circuit-breaker or a starter-controller installed in back of an enclosure to be operated from the front of the enclosure.A rotary handle can be black or red/yellow, IP54 or IP65. It includes a function for locking the circuit breaker or the starter in the O (Off) or I (On) position (depending of the type of rotary handle) by means of up to � padlocks with a shank diameter of 4 to 8 mm. The extended shaft must be adjusted to use in different size enclosures. The IP54 rotary handle is fixed with a nut (Ø ��) to make easier the assembling. The new Laser Square tool brings the accurency to align the circuit breaker and the rotary handle.
Padlockable external operators for GV3 and GV3LDescription
1 Kit handle + mounting system2 Universal handle3 Shaft4 Bracket5 Shaft support plate for deep enclosure6 Retrofit accessory7 Laser Square accessory
Kit handle + mounting systemDescription Item Reference Weight
kgFor GV3 P/L Black handle, front plate, with trip status, IP 54 1 GV3 APN01 0.�00
Red handle, front plate, with trip status, IP 54 1 GV3 APN02 0.�00Red handle, front plate, without trip status, IP 65 1 GV3 APN04 0.�00
Universal handleFor GV3 P/L Black handle, IP 54 2 GV APB54 0.140
Red handle, IP 54 2 GV APR54 0.140Red handle, IP 65 2 GV APR65 0.140
ShaftFor GV3 P/L L = �15 mm 3 GV APA1 0.110
BracketFor GV3 P/L 4 GV APH03 0.�00
Shaft support plate for deep enclosureFor GV3 P/L Depth u �00 mm 5 GV APK12 0.0�0Retrofit accessory
For GV3 P/L 6 GV APP1 0.100
Laser Square accessoryFor GV3 P/L 7 GV APL01 0.160
Sticker Sold in lots ofWarning label For French 10 - GV APSFR
For English 10 - GV APSENFor German 10 - GV APSDEFor Spanish 10 - GV APSESFor Chinese 10 - GV APSCNFor Portuguese 10 - GV APSPTFor Russian 10 - GV APSRUFor Italian 10 - GV APSIT
References TeSys protection componentsThermal-magnetic motor circuit-breakers GV� P and GV� LAdd-on blocks and accessories
�451�-EN.inddversion: 15.1
1
2
3
4
5
6
7
8
9
10
11 �451�-EN.indd version: 15.1
1�
GV3 A08GV3 A09
GV3 A01...A07
�451�-EN.inddversion: 15.1
1
2
3
4
5
6
7
8
9
10
1�
For thermal-magnetic motor circuit-breakers GV3 ME80Contact blocksDescription Type of standard
early break contactsReference Weight
kgInstantaneous auxiliary contact blocks (1 per circuit-breaker)
N/C + N/O GV3 A01 0,060N/O + N/O GV3 A02 0.060N/C + N/O + N/O GV3 A03 0.070N/O + N/O + N/O GV3 A05 0.070N/O + N/O + � volt-free terminals GV3 A06 0.070N/C + N/O + � volt-free terminals GV3 A07 0.070
Fault signalling contacts (1) N/C GV3 A08 0.0�0N/O GV3 A09 0.0�0
Electric tripsDescription Voltages Reference Weight
50 Hz 60 Hz kgUdervoltage trips (1) 110, 1�0, 1�7 V 1�0, 1�7 V GV3 B11 0.070
��0, �40 V �77 V GV3 B22 0.070�80, 415 V 440 V, 480 V GV3 B38 0.070
Shunt trips (1) 110, 1�0, 1�7 V 1�0, 1�7 V GV3 D11 0.070 ��0, �40 V �77 V GV3 D22 0.070�80, 415 V 440 V, 480 V GV3 D38 0.070
AccessoryDescription Sold in
lots ofUnit reference
Weightkg
Padlocking device, for locking the Start button (on open-mounted product)
5 GV1 V02 0.010
For magnetic circuit-breaker GK3 EF80Contact blocksDescription Number of poles Reference Weight
kgAuxiliary contact blocks for On-Off signalling and “control circuit test” function (1 or � blocks per device) mounted on RH side of GK� EF80
N/O GK2 AX10 0.0�5N/O + N/O GK2 AX20 0.0�1N/C + N/O GK2 AX50 0.0�1
Instantaneous fault signalling contact blocks (1 or � blocks per device) mounted on LH side of GK� EF80
N/O GK2 AX12 0.0�5N/O + N/O GK2 AX22 0.0�1N/C + N/O GK2 AX52 0.0�1
AccessoriesDescription Reference Weight
kgPadlocking device for padlocking the operator, using up to 3 padlocks (padlocks to be ordered separately)
GK3 AV01 0.0�0
External operator for mounting on enclosure door. Red Ø 40 knob on yellow plate, padlockable in position O (with up to 3 padlocks). Door locked when knob in position I, and when knob padlocked in position O.
GK3 AP03 0.�00
(1) 1 voltage trip OR 1 fault signalling contact to be fitted inside the motor circuit-breaker.
Other versions
�4 to 690 V, 50 or 60 Hz voltage trips for circuit-breakers GV3 ME80.Please consult your Regional Sales Office.
Characteristics:pages �451�/� and �451�/6
Dimensions:pages �45�8/11 and �45�7/6
Characteristics:pages �451�/� and �451�/6
Dimensions:pages �45�8/11 and �45�7/6
Characteristics:pages �451�/� and �451�/6
Dimensions:pages �45�8/11 and �45�7/6
Characteristics:pages �451�/� and �451�/6
Dimensions:pages �45�8/11 and �45�7/6
References TeSys protection componentsMotor circuit-breakers GV� ME80 and GK� EF80Add-on blocks and accessories
�451�-EN.indd version: 15.1
14
GV7 RE, RS
GV7 AE11, AB11
GV7 AU, AS
12
34
�451�-EN.inddversion: 15.1
1
2
3
4
5
6
7
8
9
10
15
Add-on auxiliary contactsThese allow remote indication of the circuit-breaker contact states. They can be used for signalling, electrical locking, relaying, etc. They are available in two versions: standard and low level. They include a terminal block and the auxiliary circuits leave the circuit-breaker through a hole provided for this purpose.They perform the following functions, depending on where they are located in the circuit-breaker:
Location Function Application1 and/or 4 C/O contact Indicates the position of the circuit-breaker poles2 Trip indication Indicates that the circuit-breaker has tripped due to an
overload, a short-circuit, a differential fault or the operation of a voltage trip (undervoltage or shunt trip), or of the “push to trip” test button. It resets when the circuit-breaker is reset.
3 Electrical fault indication Indicates that the circuit-breaker has tripped due to an overload, a short-circuit or a differential fault. It resets when the circuit-breaker is reset.
Type Reference Weightkg
Standard GV7 AE11 0.015
Low level GV7 AB11 0.015
Fault discrimination devicesThese make it possible to:
either differentiate a thermal fault from a magnetic fault,or open the contactor only in the event of a thermal fault.
bb
Voltage Reference Weightkg
a 24...48 and c 24…72 V GV7 AD111 (1) 0.100
z 110…240 V GV7 AD112 (1) 0.100
Electric tripsThese allow the circuit-breaker to be tripped via an electrical control signal.
Undervoltage trip GV7 AUTrips the circuit-breaker when the control voltage drops below the tripping threshold, which is between 0.�5 and
0.7 times the rated voltage.Circuit-breaker closing is only possible if the voltage exceeds 0.85 times the rated voltage.
Circuit-breaker tripping by a GV7 AU trip meets the requirements of IEC 60947-�.
Shunt trip GV7 ASTrips the circuit-breaker when the control voltage rises above 0.7 times the rated voltage.
Operation (GV7 AU or GV7 AS)When the circuit-breaker has been tripped by a GV7 AU or AS, it must be reset either locally or by remote control.
(For remote control, please consult your Regional Sales Office).Tripping has priority over manual closing: if a tripping instruction is present, manual action does not result in
closing, even temporarily, of the contacts.Durability: 50 % of the mechanical durability of the circuit-breaker.
bv
v
b
bv
v
v
Type Voltage Reference Weightkg
Undervoltage trip 48 V, 50/60 Hz GV7 AU055 (1) 0.105110…1�0 V, 50/60 Hz GV7 AU107 (1) 0.110�00…�40 V, 50/60 Hz GV7 AU207 (1) 0.110�80…440 V, 50/60 Hz GV7 AU387 (1) 0.1055�5 V, 50 Hz GV7 AU525 (1) 0.100
Shunt trip 48 V, 50/60 Hz GV7 AS055 (1) 0.105110…1�0 V, 50/60 Hz GV7 AS107 (1) 0.110�00…�40 V, 50/60 Hz GV7 AS207 (1) 0.110�80…440 V, 50/60 Hz GV7 AS387 (1) 0.1055�5 V, 50 Hz GV7 AS525 (1) 0.100
(1) For mounting of a GV7 AD or a GV7 AU or AS.
Characteristics:pages �451�/�, �451�/6 and �451�/7
Dimensions:pages �45�8/7 to �45�8/9
Schemes:page �45�8/11
Characteristics:pages �451�/�, �451�/6 and �451�/7
Dimensions:pages �45�8/7 to �45�8/9
Schemes:page �45�8/11
Characteristics:pages �451�/�, �451�/6 and �451�/7
Dimensions:pages �45�8/7 to �45�8/9
Schemes:page �45�8/11
Characteristics:pages �451�/�, �451�/6 and �451�/7
Dimensions:pages �45�8/7 to �45�8/9
Schemes:page �45�8/11
References TeSys protection componentsThermal-magnetic motor circuit-breakers GV7 R with screw clamp connectionsAdd-on blocks and accessories
�451�-EN.indd version: 15.1
16
ON
OFFO
ON
OFFO
ON
OFFO
OFFO
ON
ON
OFFO
GV7 RE, RS
GV7 AP03
OFFO
ON
GV7 AP04
GV7 AP01, AP02
GV7 V01
GV7 AP05
GV7 RE, RS
GV7 AC01
GV7 AC03 GV7 AC01
GV7 AC04
GV7 AC04
�451�-EN.inddversion: 15.1
1
2
3
4
5
6
7
8
9
10
17
Cabling accessoriesDescription Application For use on
contactorsSold in lots of
Unit reference
Weight
kgClip-on connectors for GV7 R
Up to 150 A, 1.5…95 mm� – � GV7 AC021 0.�00
Up to ��0 A, 1.5…185 mm� – � GV7 AC022 0.�50
Spreader �-pole (1)
To increase the pitch to 45 mm – 1 GV7 AC03 0.180
Terminal shields IP 405 (1)
Supplied with sealing accessory
– 1 GV7 AC01 0.1�5
Phase barriers Safety accessories used when fitting of shields is impossible
– � GV7 AC04 0.075
Insulating screens Ensure insulation between the connections and the backplate
– � GV7 AC05 0.075
Kits for combination with contactor(2)
Allowing link between the circuit-breaker and the contactor. The cover provides protection against direct finger contact
LC1 F115…F185 1 GV7 AC06 0.550
LC1 F��5 and F�65 1 GV7 AC07 0.550
LC1 D115 and D150 1 GV7 AC08 0.550
Direct rotary handleReplaces the circuit-breaker front cover; secured by screws. It includes a device for locking the circuit-breaker in the O (Off) position by means of up to � padlocks with a shank diameter of 5 to 8 mm (padlocks not included). A conversion accessory allows the direct rotary handle to be mounted on the enclosure door. In this case, the door cannot be opened if the circuit-breaker is in the “ON” position. Circuit-breaker closing is inhibited if the enclosure door is open.
Description Type Degree of protection
Reference Weightkg
Direct rotary handle Black handle, black legend plate IP 40 GV7 AP03 0.�05
Red handle, yellow legend plate IP 40 GV7 AP04 0.�05
Adapter plate (3) Four mounting direct rotary handle on enclosure door
IP 4� GV7 AP05 0.100
Extended rotary handleAllows a circuit-breaker installed in the back of an enclosure to be operated from the front of the enclosure. It comprises:
a unit which screws onto the front cover of the circuit-breaker,an assembly (handle and front plate) to be fitted on the enclosure door,an extension shaft which must be adjusted (distance between the mounting surface and the door: 185 mm
minimum, 600 mm maximum). It includes a device for locking the circuit-breaker in the O (Off) position by means of up to � padlocks with a shank diameter of 5 to 8 mm (padlocks not included). This prevents the enclosure door from being opened.
bbb
Description Type Degree of protection
Reference Weightkg
Extended rotary handle Black handle, black legend plate IP 55 GV7 AP01 0.775
Red handle, yellow legend plate IP 55 GV7 AP02 0.775
Locking deviceAllows circuit-breakers not fitted with a rotary handle to be locked in the O (Off) position by means of up to � padlocks with a shank diameter of 5 to 8 mm (padlocks not included).
Description Application Reference Weightkg
Locking device For circuit-breaker not fitted with a rotary handle GV7 V01 0.100
(1) Terminal shields cannot be used together with spreaders.(2) The kit comprises links, a protective shield and a depth adjustable metal bracket for the breaker.(3) This conversion accessory makes it impossible to open the door if the device is closed and prevents the device from being
closed if the door is open.
+
+
GV7 AC07
+
+
GV7 AC07
+
GV7 AC08
+
GV7 AC08
Dimensions:pages �45�8/7 to �45�8/9
Schemes:page �45�8/11
Dimensions:pages �45�8/7 to �45�8/9
Schemes:page �45�8/11
Dimensions:pages �45�8/7 to �45�8/9
Schemes:page �45�8/11
Dimensions:pages �45�8/7 to �45�8/9
Schemes:page �45�8/11
References TeSys protection componentsThermal-magnetic motor circuit-breakers GV7 R with screw clamp connectionsAccessories
�451�-EN.indd version: 15.1