4
OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Instructions subject to change without prior notification. Orgatech | 205 W. Blueridge Ave |Orange, CA 92865 | Phone: 626-969-6820 | www.orgatech.com 10/2018 1 AC LEDStrip Please read these instructions carefully before using product. Observe all safety warnings. Failure to comply with these instructions could result in serious injury and/or damage to product or property. DO NOT CUT OR SHORTEN THE LED STRIP. DOING SO CAN CAUSE RISK OF ELECTRICAL SHOCK. IMPORTANT SAFETY INSTRUCTIONS Do not cover the LEDStrip - This may may cause the flexible light to overheat and melt or ignite. Do not operate with the LEDStrip while it is coiled. Do not cut, puncture, splice or shorten the LED Strip. Do not route the LEDStrip cable or cord through walls, doors, windows or any similar part of the building structure. Do not use if there is any damage to the light or cord insulation. Do not submerge flexible light in liquids or use the product in the vicinity of standing water or other liquids. Secure this flexible light using only only hangers or clips provided. Using items such as staples, nails, or similar items may damage the insulation. Do not allow the LEDStrip to be flexed continuously. Do not exceed the maximum length allowed as written on the LEDStrip Follow all safety instructions. If you do not have adequate electrical wiring experience, have this installed by a qualified licensed electrician. Electrical connections must be in accordance with local codes, ordinances and the National Electric Code. This product operates on 120 VAC; always confirm the maximum wattage of the linear strip does not exceed the maximum wattage of the circuit it is connected to. Do not install the LEDstrip if any visible damage is seen on the LEDStrip or power cords or jumper cables. Before starting the installation, ensure power is disconnected at the circuit breaker. 1 2 3 4 5 USE FLEXIBLE CONDUIT ONLY All electrical connections must be in accordance with local codes, ordinances and the National Electric Code. This product operates on 120 VAC. You must confirm the maximum wattage of the linear strip does not exceed the maximum wattage of the circuit it is connected to. If you are not familiar with the installation of electrical wiring, hire a qualified licensed electrician. DO NOT POWER THE ACLED STRIP WHEN ATTACHED TO THE SPOOL OR TIGHTLY COILED. DO NOT CUT THE AC LEDStrip IP65 2” bend radius minimum 8 9 1 2 3 4 5 6 7

AC LEDStrip OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS › wp-content › uploads › 2018 › 10 › AC... · OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Instructions subject to change

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AC LEDStrip OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS › wp-content › uploads › 2018 › 10 › AC... · OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Instructions subject to change

OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS

Instructions subject to change without prior notification.

Orgatech | 205 W. Blueridge Ave |Orange, CA 92865 | Phone: 626-969-6820 | www.orgatech.com

10/2018 1

AC LEDStrip

Please read these instructions carefully before using product. Observe all safety warnings. Failure to comply with these instructions could result in serious injury and/or damage to product or property.

DO NOT CUT OR SHORTEN THE LED STRIP. DOING SO CAN CAUSE RISK OF ELECTRICAL SHOCK.

IMPORTANT SAFETY INSTRUCTIONS

Do not cover the LEDStrip - This may may cause the flexible light to overheat and melt or ignite. Do not operate with the LEDStrip while it is coiled. Do not cut, puncture, splice or shorten the LED Strip. Do not route the LEDStrip cable or cord through walls, doors, windows or any similar part of the building structure. Do not use if there is any damage to the light or cord insulation. Do not submerge flexible light in liquids or use the product in the vicinity of standing water or other liquids.

Secure this flexible light using only only hangers or clips provided. Using items such as staples, nails, or similar items may damage the insulation. Do not allow the LEDStrip to be flexed continuously. Do not exceed the maximum length allowed as written on the LEDStrip

Follow all safety instructions.

If you do not have adequate electrical wiring experience, have this installed by a qualified licensed electrician.

Electrical connections must be in accordance with local codes, ordinances and the National Electric Code. This product operates on 120 VAC; always confirm the maximum wattage of the linear strip does not exceed the maximum wattage of the circuit it is connected to.

Do not install the LEDstrip if any visible damage is seen on the LEDStrip or power cords or jumper cables.

Before starting the installation, ensure power is disconnected at the circuit breaker.

1

2

3

4

5

USE FLEXIBLE CONDUIT ONLY

All electrical connections must be in accordance with local codes, ordinances and the National Electric Code. This product operates on 120 VAC. You must confirm the maximum wattage of the linear strip does not exceed the maximum wattage of the circuit it is connected to. If you are not familiar with the installation of electrical wiring, hire a qualified licensed electrician.

DO NOT POWER THE ACLED STRIP WHEN ATTACHED TO THE SPOOL OR TIGHTLY COILED.

DO NOT CUT THE AC LEDStrip

IP65

2” bend radius

minimum

89

1234567

Page 2: AC LEDStrip OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS › wp-content › uploads › 2018 › 10 › AC... · OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Instructions subject to change

Instructions subject to change without prior notice. 10/2018 2

AC LEDStripMOUNTING OPTIONS

Mounting Channel

Mounting Clips Mounting Clips

Drawing is a representation of three sections of AC LEDStrip in one run using methods 1, 2 & 3

Mounting Clips

Secure the mounting clips on the AC LEDStrip with self-tapping screws. Install the hardware clips 6" apart to prevent sagging on face-down application, NOTE: used to secure the beginning and the end of each section of the AC LEDStrip.

Secure mounting channel to the mounting surface with self-tapping screws every 6 inches. NOTE: 2 hardware clips must be used to secure the beginning and the end of each section of the AC LEDStrip.

Secure the mounting U channel clips on wall or other surfaces with self-tapping screws every 6 inches. NOTE: 2 hardware clips must be used to secure the beginning and the end of each section of AC LEDStrip.

FOR DOWN FACING OR VERTICAL APPLICATIONS Use m 1 a mounting

FOR UP FACING OR HORIZONTAL APPLICATIONS Use m 1,2 3

Jumper Cable

Jumper Cable

6 in

6 in

UL requires that two mounting clips must be used in mounting at the beginning and end of each section of the AC LEDStrip in a run.

1

1

2

3

2 3+ + + Mounting Clips & Mounting Clips

2 Mounting Clips are required per section

Mounting Clips & Mounting Channel

6 in

Mounting Clips &Mounting U Channel Clips |

AC LEDStrip

6 in Mounting Clips

6in

Mounting Clips Allow 1/8” clearance

Orgatech | 205 W. Blueridge Ave |Orange, CA 92865 | Phone: 626-969-6820 | www.orgatech.com

IP65

Page 3: AC LEDStrip OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS › wp-content › uploads › 2018 › 10 › AC... · OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Instructions subject to change

Instructions subject to change without prior notice. 10/2018 3

INSTALLING WITH A NEMA 4x ENCLOSURE

FLEXIBLE CONDUIT ONLY FOR INPUT AND OUTPUT NEVER POWER THE STRIP LIGHT WHILE

ATTACHED TO A SPOOL OR WHEN TIGHTLY COILED.

TURN OFF THE ELECTRICITY at the circuit breaker box before beginning installation by switching circuit breaker off or removing fuse. MIN 90º C SUPPLY CONDUCTORS.

LIQUID-TIGHT NONMETALLIC FLEXIBLE CODUIT (Not Included)

WIRE NUTS (Not Included)

NEMA 4X ENCLOSURE (Not Included)

COUPLER(Not Included)

REQUIRED PARTS FOR INSTALLATION

CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT

ON OFF1

TURN OFF ELECTRICITY AT MAIN FUSE BOX

NOTE: ALL CONNECTIONS MUST BE PROPERLY SECURED AND SEALED FOR OUTDOOR INSTALLATIONS.

NEMA 4X RATED ENCLOSURE WITH SURGE PROTECTOR AND CONNECTIONS TO 1/2ӯ NON-METALLIC FLEXIBLE CONDUIT

TYPICAL INSTALLATION

COUPLER 1/2” LIQUID-TIGHT FLEXIBLE CONDUIT CONNECTOR TO 1/2” LIQUID-TIGHT CORD GRIP CONNECTOR

1/2” LIQUID-TIGHT NONMETALLIC FLEXIBLE CONDUIT (Not Included)

NEMA 4X ENCLOSURE

1/2” LIQUID-TIGHT NONMETALLIC FLEXIBLE CONDUIT(Not Included)

1/2” NON-METALLIC LIQUID-TIGHT FLEXIBLE CONDUITMUST BE UL, ETL OR CSA APPROVED

REQUIRED FOR INPUT AND OUTPUT CONNECTION

COUPLER

AC LEDStrip

Orgatech | 205 W. Blueridge Ave |Orange, CA 92865 | Phone: 626-969-6820 | www.orgatech.com

AC LEDStrip

IP65

Page 4: AC LEDStrip OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS › wp-content › uploads › 2018 › 10 › AC... · OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Instructions subject to change

Instructions subject to change without prior notice. 10/2018 4

INSTALLING NEMA 4x ENCLOSURE

TURN OFF ELECTRICITY at main fuse box (or circuit breaker box) before beginning installation by switching circuit breaker off or removing fuse. MIN 90º C SUPPLY CONDUCTORS.

CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT

*DO NOT REMOVE SURGE PROTECTION MODULEThis is a violation of UL requirements and will voidthe product warranty.

LIQUID-TIGHT NONMETALLIC FLEXIBLE CONDUIT COUPLER AC LEDStrip

LIQUID-TIGHT NONMETALLIC FLEXIBLE CONDUIT

COUPLER

1/2” LIQUID-TIGHT FLEXIBLE CONDUIT CONNECTOR

1/2” LIQUID-TIGHT CORD GRIP CONNECTORHARDWIRE CABLE

MOUNTING SCREWS (X4)

NEMA 4x ENCLOSURE

LIQUID-TIGHT NONMETALLIC FLEXIBLE CONDUIT

SUPPLY WIRES

SURGE PROTECTION MODULE*

BLACK (HOT)WHITE (NEUTRAL)GREEN OR COPPER (GROUND)

BROWN TO WHITEBLUE TO BLACK

SUPPLY WIRES

A-A

5-1 5-2B-B

SURGE PROTECTION MODULE INPUT WIRES

SURGE PROTECTION MODULE OUTPUT WIRES

AC LEDStrip INPUT WIRES

INPUT1/2” LIQUID-TIGHT FLEXIBLE CONDUIT CONNECTOR

INPUT1/2” LIQUID-TIGHT FLEXIBLE CONDUIT CONNECTOR

OUTPUT1/2” LIQUID-TIGHT FLEXIBLE CONDUIT CONNECTOR

1 2

3

4

5

1 Unscrew and remove the mounting screws and remove the lid from NEMA 4x ENCLOSURE.

2 Feed the supply wires and liquid-tight non metalic flexible conduit to INPUT 1/2” liquid-tight flexible conduit connector (pre-measure and cut flexible conduit to the desired length).

3 Feed the hardwire cable through the flexible conduit followed by a 1/2” liquid-tight nonmetallic flexible conduit. Secure HARDWIRE cable onto the AC LEDStrip by tightening the 1/2” liquid-tight cord grip connector.

4 Insert liquid-tight nonmetallic flexible conduit into the cord grip connector. Tighten 1/2” liquid-tight flexble conduit connector to secure.

5 -1

1. Connect hot supply wire (black) to surgeprotection module’s hot input wire (black).2. Connect neutral supply wire to (white) surgeprotection module’s neutral input wire (white).3. Connect supply ground wire (green or barecopper) to surge protection module’s ground inputwire (green).Secure all connections with wire nuts (notincluded).

5 - 21. Connect surge protection module’s hot outputwire (white) to AC LEDStrip’s hot input wire (brown).2. Connect surge protection module’s neutraloutput wire (black) to AC LEDStrip’s neutral input wire (blue).

5 Carefully tuck all connected wires inside the NEMA 4x ENCLOSURE. Secure lid to the NEMA 4x ENCLOSURE with 4 mounting screws. making sure to not pinch any wires or wire nuts.

NOTE: ALL CONNECTIONS MUST BE PROPERLY SEURED AND SEALED FOR OUTDOOR INSTALLATIONS.

Orgatech | 205 W. Blueridge Ave |Orange, CA 92865 | Phone: 626-969-6820 | www.orgatech.com

AC LEDStrip