a380-Level III - Ata 38 Water_waste

Embed Size (px)

DESCRIPTION

Airbus A380 Technical Training Manual (TTM)Full DocumentNew VersionThe first A380 technical manual, the "Airplane Characteristics for Airport Planning," was released this month. It can be consulted and/or downloaded from the A380 Family page on Airbus' web site at www.airbus.com. This is the first time a technical manual of this nature has been made available so early, some three years before the first flight of the aircraft.The Airplane Characteristics manual provides specific A380 data needed by airport authorities and planners to support the operation of the A380 within their airports. Data such as airplane dimensions, take off and landing distances, terminal operations data, taxiing, parking and pavement loading requirements are provided for the A380-800 and A380-800F, the passenger and freighter versions of the A380.Airbus has been working with planning teams from 50 major airports in five continents to ensure smooth handling of the A380 when it enters service in 2006 and the Airplane Characteristics manual is a major support for this.Following release of this first manual and up to entry into service of the A380, Airbus will deliver a full range of technical data for the maintenance, engineering, material support and flight operations departments of A380 airline customers. Technical data for the A380 will be available in electronic format according to the most recent aviation industry standards, which are more efficient and user friendly. They will be accessible through Airbus On Line Services, the Airbus portal for Customer Support.

Citation preview

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    1/40

    A380TECHNICAL TRAINING MANUAL

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    2/40

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    3/40

    This document must be used for training purposes only

    Under no circumstances should this document be used as a reference

    It will not be updated.

    All rights reserved

    No part of this manual may be reproduced in any form,

    by photostat, microfilm, retrieval system, or any other means,

    without the prior written permission of AIRBUS S.A.S.

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    4/40

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    5/40

    LEVEL III - ATA 38 WATER/WASTEPotable Water System Description (3) . . . . . . . . . . . . . . . . . . . . . . . . . 2

    Toilet System Description (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    Waste Water Drain System Description (3) . . . . . . . . . . . . . . . . . . . . 28

    Water/Waste System Maintenance (3) . . . . . . . . . . . . . . . . . . . . . . . . 30Water/Waste System Component Location (3) . . . . . . . . . . . . . . . . . 34

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TABLE OF CONTENTS Mar 21, 2006

    Page 1

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    6/40

    POTABLE WATER SYSTEM DESCRIPTION (3)

    General Architecture

    The potable water tanks are installed in the FWD area of the AFT cargo

    compartment, above the body landing gear boxes (three on the LH side

    and three on the RH side). As option, two additional tanks can be installed

    (one on each side). Each tank has a capacity of 283 liters (75 US gallons)

    for a basic total volume of 1700 liters (449 US gallons).

    The potable water is distributed to the galley and lavatory faucets and to

    the toilets and Galley Waste Disposal Units (GWDUs) for flushing.

    Two compressors fulfill the tanks pressurization. For maintenance, it is

    possible to pressurize the tanks by using a ground pressure connection.

    Before distribution, a treatment module filters, heats and purifies the

    potable water.

    The filling of the water tanks is done from the potable water service panelinstalled in the AFT lower fuselage. The draining of the complete system

    is done from the potable water service panel and from the FWD drain

    panel installed in the FWD lower fuselage.

    A depress valve, installed near the service panel, is used for system

    depressurization on ground.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 2

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1POTABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    7/40

    GENERAL ARCHITECTURE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 3

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1POTABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    8/40

    POTABLE WATER SYSTEM DESCRIPTION (3)

    Potable Water Storage

    The potable water tanks numbering is organized as follows:

    - tanks number 1, 3, 5 (and 7 as option) on the LH side,

    - tanks number 2, 4, 6 (and 8 as option) on the RH side.

    Each tank has a recirculation port, an overflow port and a fill/drain port.

    The middle tanks number 3 and 4 have an ultrasonic level sensor installed

    in the bottom.

    Note that the level sensors transmit the water level data to the Potable

    Water Indication Panel (PWIP) for calculation. The average value of the

    water quantity in the tanks is shown on the FAPs and on the PWIP.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 4

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1POTABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    9/40

    POTABLE WATER STORAGE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 5

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1POTABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    10/40

    POTABLE WATER SYSTEM DESCRIPTION (3)

    Air Supply System

    The air supply system supplies pressurized air to the potable water system

    by means of two compressors installed on the LH side near the potable

    water tanks.

    The normal operating pressure of the system is between 35 psi and 41

    psi.

    An electric motor operates each compressor. An air compressor motor

    controller, installed near the compressors, controls each motor.

    The air is picked-up in the cargo compartment through an inlet filter

    mounted on each compressor, and sent under pressure to an air manifold

    assembly installed above the compressors.

    The air manifold assembly has:

    - two pressure switches (one low pressure and one high pressure) for afeedback to the controllers,

    - an over pressure relief valve, which opens when the pressure reaches

    130 psi,

    - a ground pressure connection,

    - filters, to make sure that unwanted material do not go into the potable

    water system,

    - air check valves, to prevent a backflow of air.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 6

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    11/40

    AIR SUPPLY SYSTEM

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 7

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    12/40

    POTABLE WATER SYSTEM DESCRIPTION (3)

    Potable Water Treatment Module

    The potable water treatment module, installed on the RH side near the

    potable water tanks, has:

    - a circulation pump, installed just near the treatment module on the inlet

    pipe. The pump, driven by an electric motor, helps the water circulation

    inside the module,

    - an inhibition of scaling module, which has a magnetic tube removing

    scale deposits and particles. There is no maintenance servicing on it,

    - a water heater, which warms-up the water entering in the loop.

    The heating and disinfection control unit manages all the electrical

    components of the potable water treatment module. It switches ON/OFF

    the circulation pump as well as the water heater, in order to keep a

    temperature range of 6-15C.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 8

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    13/40

    POTABLE WATER TREATMENT MODULE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 9

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    14/40

    POTABLE WATER SYSTEM DESCRIPTION (3)

    Lavatory Water Supply Assembly

    The lavatory water supply assembly has:

    - a manual shut-off valve, installed below the sink. It isolates the water

    going to the faucet and also to the toilet unit for flushing,

    - a water heater, which warms-up the water up to 50C,

    - a mixing unit, which mixes the hot and cold water to satisfy the water

    supply temperature demand.

    The lavatory water supply assembly control device receives the

    temperature demand from the infrared controlled faucet and manages the

    mixing process accordingly.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 10

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    15/40

    LAVATORY WATER SUPPLY ASSEMBLY

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 11

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    16/40

    POTABLE WATER SYSTEM DESCRIPTION (3)

    Control System Architecture

    The PWIP, the heating and disinfection control unit, the air compressor

    motor controllers and the lavatory water supply assembly control devicesmonitor and control the performance of their related system components.

    Note that the PWIP manages the potable water quantity (level sensors

    signal), the pre-selection and the valves operations (fill/drain, FWD drain

    and depress valves).

    The PWIP and the FAPs are the main controllers and indicators of the

    potable water system.

    The Cabin Intercommunication Data System (CIDS) directors, through

    the vacuum system control function, manage the data exchange between

    the potable water system components and some A/C systems like:

    - the FAPs,- the Onboard Maintenance System (OMS) for failure report and tests,

    - the Landing Gear Extraction Retraction System (LGERS).

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 12

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    17/40

    CONTROL SYSTEM ARCHITECTURE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 13

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    18/40

    POTABLE WATER SYSTEM DESCRIPTION (3)

    Water/Waste FAP Page

    The Water/Waste FAP page has the following functions:

    - indication of potable water quantity in the tanks,- indication of A/C configuration (location of lavatories and galleys),

    - indication of system status,

    - indication of failure messages,

    - system depressurization on ground ("Water Depr." button),

    - system depressurization in flight ("Shut Down" button),

    - isolation of water distribution areas ("Shut Off LH" and "Shut Off RH"

    buttons),

    - water pre-selection ("Pre-Select" button).

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 14

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    19/40

    WATER/WASTE FAP PAGE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    POTABLE WATER SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 15

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D1PO

    TABLE01

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    20/40

    TOILET SYSTEM DESCRIPTION (3)

    General Architecture

    The toilet system is divided into four independent subsystems, which

    are:- the LH main deck,

    - the RH main deck,

    - the LH upper deck and,

    - the RH upper deck.

    Each subsystem has:

    - toilet assemblies,

    - Galley Waste Disposal Units (GWDUs),

    - a waste tank,

    - a waste separator with filter,

    - a high level sensor,- two absolute pressure sensors,

    - an overboard check valve,

    - a vacuum generator,

    - a waste drain valve connected to an individual control handle on the

    waste service panel.

    The waste tanks are installed in the under floor area behind the bulk cargo

    compartment. The tanks for the main deck toilets and GWDUs have a

    capacity of 675 liters each (178 US gallons). The tanks for the upper deck

    toilets and GWDUs have a capacity of 373 liters each (98 US gallons).

    The toilet system uses potable water to flush the toilets and the GWDUs.

    The waste materials are transported into the waste tanks through flushvalves by cabin differential pressure.

    When this differential pressure is insufficient, at altitudes below 16000

    ft., the vacuum generators generate the necessary vacuum in the waste

    tanks to fulfill the waste flow.

    During servicing, the waste tanks are drained then rinsed from the waste

    service panel installed in the AFT lower fuselage.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 16

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TO

    ILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    21/40

    GENERAL ARCHITECTURE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 17

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TO

    ILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    22/40

    TOILET SYSTEM DESCRIPTION (3)

    Toilet Assembly and GWDU

    The toilet assembly and the GWDU have:

    - a flush switch, which initiates the actuation of a flush sequence,- a rinse valve, which opens to spray potable water into the bowl for

    rinsing,

    - a flush valve, which opens to evacuate the waste materials to the waste

    tanks,

    - a Multi Purpose Interface (MPI) installed on the toilet or the GWDU

    frame, which controls and sequences the rinse and flush functions.

    Using the data from the weight sensing device, the toilet assembly MPI

    can discriminate between a "seated" and a "standing" user and vary the

    rinse water quantity accordingly. The MPI starts a short flush cycle for

    a "standing" user and a long flush cycle for a "seated" user.The GWDU has two flushing modes:

    - mode 1: wet flush, used for waste materials discard. The GWDU MPI

    carries out a flush sequence with rinsing by using potable water.

    - mode 2: dry flush, used for liquids discard only. The GWDU MPI carries

    out a flush sequence without rinsing, in order to reduce the consumption

    of potable water when not required. Pressing twice in a second the flush

    switch activates this special mode.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 18

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TO

    ILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    23/40

    TOILET ASSEMBLY AND GWDU

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 19

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TO

    ILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    24/40

    TOILET SYSTEM DESCRIPTION (3)

    Waste Tank Assembly and Associated Equipment

    The waste tank assembly has:

    - a waste tank,- a waste inlet with a flow diverter, which directs the waste materials to

    the bottom of the tank,

    - a waste separator with a filter, which separates the waste materials from

    the air to make sure that only clean air will flow overboard,

    - an ambient absolute pressure sensor installed on the air outlet of the

    waste separator, which measures the air pressure above the waste surface

    in the waste tank,

    - a hydrostatic absolute pressure sensor installed at the bottom of the

    waste tank, which measures the hydrostatic pressure. It calculates the

    waste level in the tank with the received ambient and hydrostatic data,- a high level sensor installed in the upper section of the waste tank, which

    provides the "full tank" signal in order to stop the related subsystem,

    - three rinse nozzles installed on the top of the tank to rinse the tank and

    introduce disinfection fluids.

    A differential pressure is necessary to move the waste materials from the

    toilets assemblies and the GWDUs to the waste tank. To obtain the

    necessary vacuum in the tank when the altitude is below 16000 ft., a

    vacuum generator operates, creating a differential pressure between 4 psi

    (0,28 bar) and 9 psi (0,62 bar) below the cabin pressure.

    A Motor Controller Interface (MCI) installed adjacent to the vacuum

    generator controls the operation of the vacuum generator.When a flush sequence is initiated at a toilet assembly or a GWDU, the

    MCI receives a signal from the related MPI.

    Before the MCI supplies electrical power to the related vacuum generator,

    it controls the flight phase data (ground signal, altitude) received from

    the Landing Gear Extraction Retraction System (LGERS) and the Air

    Data/Inertial Reference Units (ADIRUs) through the Cabin

    Intercommunication Data System (CIDS).

    Note that the MCI also receives a discrete landing gear status signal in

    case of CIDS lost.

    The MCI is connected to the service panel limit switch. Thus, when the

    waste service panel door is opened and the A/C is on ground, the operationof the toilet system is inhibited.

    Finally, the MCI is connected to the related high level sensor. Thus, when

    a "full tank" signal is detected, the related subsystem is inhibited in order

    to prevent an overflow of the waste materials storage.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 20

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TO

    ILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    25/40

    WASTE TANK ASSEMBLY AND ASSOCIATED EQUIPMENT

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 21

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TO

    ILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    26/40

    TOILET SYSTEM DESCRIPTION (3)

    Flush Sequence

    The activation of the flush switch on a toilet assembly or on a GWDU

    initiates the actuation of a flush sequence.The related MPI starts a timed sequence that includes the analysis of the

    flush requirements (control of the flight phase data, "standing" or "seated

    user", dry or wet flush...) before the flush cycle starts.

    For a toilet assembly:

    - 2.1 seconds after the beginning of the flush cycle, the rinse valve opens

    during 0.9 second for a long flush ("seated" user), and during 0.3 second

    for a short flush ("standing" user).

    - 2.5 seconds after the beginning of the flush cycle, the flush valve opens

    during 4 seconds.

    The duration of the complete flush cycle is 9 seconds.For a GWDU:

    - 8 seconds maximum (according to the required vacuum pressure) after

    the beginning of the flush cycle, the rinse valve opens during 0.95 second

    for a normal wet flush. For a dry flush the rinse valve is not activated.

    - 1 second after the actuation of the rinse valve, the flush valve opens

    during 4 seconds.

    - 9 seconds after the actuation of the flush valve, the flush cycle is

    complete.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 22

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TO

    ILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    27/40

    FLUSH SEQUENCE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 23

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TOILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    28/40

    TOILET SYSTEM DESCRIPTION (3)

    Control System Architecture

    The following components have a microprocessor and are interconnected

    via CAN bus:- toilet assembly MPIs,

    - GWDU MPIs

    - vacuum generator MCIs,

    - hydrostatic and ambient absolute pressure sensors,

    - high level sensors.

    The CIDS directors, through the vacuum system control function, manage

    the data exchange between the toilet system components and some A/C

    systems like the FAPs, the Onboard Maintenance System (OMS), the

    LGERS and the ADIRUs.

    The FAPs are the main controllers and indicators of the toilet system.The interface with the OMS is used for failure report and test of the toilet

    system.

    The LGERS and ADIRUs give flight phase data (ground signal and

    altitude) for the control of the vacuum system.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 24

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TOILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    29/40

    CONTROL SYSTEM ARCHITECTURE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 25

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TOILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    30/40

    TOILET SYSTEM DESCRIPTION (3)

    Water/Waste FAP Page

    The Water/Waste FAP page has the following functions:

    - indication of waste quantity in the tanks,- indication of A/C configuration (location of lavatories and galleys),

    - indication of system status,

    - indication of failure messages,

    - auto flush ("Auto Flush" button),

    - rinse valve warning reset ("Reset Warn." button).

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 26

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TOILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    31/40

    WATER/WASTE FAP PAGE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    TOILET SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 27

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D2TOILET001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    32/40

    WASTE WATER DRAIN SYSTEM DESCRIPTION (3)

    General Architecture

    The waste water drain-system discards overboard the waste water from

    the galley sinks and the lavatory washbasins.The waste water flows through the drain valves to the FWD and the AFT

    heated drain masts installed on the lower fuselage.

    The waste water is achieved by gravity on ground and by differential

    pressure in flight.

    The diaphragm type drain valves are usually closed. They open only if

    a sufficient amount of waste water is collected. This prevents a continuous

    leakage of the cabin air through the drain lines.

    To prevent icing, the drain masts are electrically heated.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    WASTE WATER DRAIN SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 28

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D3W

    ASTE0001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    33/40

    GENERAL ARCHITECTURE

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    WASTE WATER DRAIN SYSTEM DESCRIPTION (3) Mar 17, 2006

    Page 29

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38D3W

    ASTE0001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    34/40

    WATER/WASTE SYSTEM MAINTENANCE (3)

    Potable Water System Tests

    Potable Water System (PWS) tests are done to check several functions

    of the system.

    OMS Interactive Tests Overview

    The PWS has the following interactive tests:

    - system test,

    - valve test.

    These tests are launched from the OMS HMI (using the OMT, OIT

    or PMAT).

    System Test

    The system test does a check of all monitored components of the PWS:

    - the Potable Water Indication Panel (PWIP),- the level sensors,

    - the air compressor motor controllers,

    - the heating and disinfection control unit,

    - the fill/drain valve,

    - the FWD drain valve,

    - the depress valve,

    - the optional valves.

    Valve Test

    The valve test does a check of all installed valves of the PWS:

    - the fill/drain valve,

    - the FWD drain valve,

    - the depress valve,

    - the optional valves.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    WATER/WASTE SYSTEM MAINTENANCE (3) Mar 17, 2006

    Page 30

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38Y1M

    AINT0001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    35/40

    POTABLE WATER SYSTEM TESTS - OMS INTERACTIVE TESTS OVERVIEW ... VALVE TEST

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    WATER/WASTE SYSTEM MAINTENANCE (3) Mar 17, 2006

    Page 31

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38Y1M

    AINT0001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    36/40

    WATER/WASTE SYSTEM MAINTENANCE (3)

    Vacuum Toilet System Tests

    Vacuum Toilet System (VTS) tests are done to check several functions

    of the system.

    OMS Interactive Tests Overview

    The VTS has the following interactive tests:

    - system test,

    - subsystem test MD/LH,

    - subsystem test MD/RH,

    - subsystem test UD/LH,

    - subsystem test UD/RH.

    These tests are launched from the OMS HMI (using the OMT, OIT

    or PMAT).

    System Test

    The system test does a check of all monitored components of the VTS:

    - the vacuum generator Motor Controller Interfaces (MCIs) of all four

    subsystems,

    - the liquid level sensors of all four subsystems,

    - the absolute pressure sensors of all four subsystems,

    - the Multi Purpose Interfaces (MPIs) of all toilet assemblies and

    Galley Waste Disposal Units (GWDUs) (refer to cabin layout).

    Subsystem Test

    The test of each vacuum toilet subsystem does a check of its relatedmonitored components:

    - the vacuum generator MCI,

    - the liquid level sensor,

    - the two absolute pressure sensors,

    - the MPIs of the related toilet assemblies and GWDUs.

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    WATER/WASTE SYSTEM MAINTENANCE (3) Mar 17, 2006

    Page 32

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38Y1M

    AINT0001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    37/40

    VACUUM TOILET SYSTEM TESTS - OMS INTERACTIVE TESTS OVERVIEW ... SUBSYSTEM TEST

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    WATER/WASTE SYSTEM MAINTENANCE (3) Mar 17, 2006

    Page 33

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38Y1M

    AINT0001

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    38/40

    WATER/WASTE SYSTEM COMPONENT LOCATION (3)

    FWD Fuselage

    Rear Cargo Compartment

    Potable Water

    Waste Equipments

    Cabin

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    WATER/WASTE SYSTEM COMPONENT LOCATION (3) Mar 17, 2006

    Page 34

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38C1LEVEL0301

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    39/40

    This Page Intentionally Left Blank

    MAINTENANCE COURSE - T1 & T2 (RR / Metric)LEVEL III - ATA 38 Water/Waste

    WATER/WASTE SYSTEM COMPONENT LOCATION (3) Mar 17, 2006

    Page 35

    A380 TECHNICAL TRAINING MANUAL

    L0Y06082-L0DT0T0-LM38C1LEVEL0301

  • 5/25/2018 a380-Level III - Ata 38 Water_waste

    40/40

    AIRBUS S.A.S.

    31707 BLAGNAC cedex, FRANCE

    STM

    REFERENCE L0Y06082

    MARCH 2006

    PRINTED IN FRANCE

    AIRBUS S.A.S. 2006

    ALL RIGHTS RESERVED

    AN EADS JOINT COMPANY

    WITH BAE SYSTEMS