Details[Phenomenon]Fogged or ghost images may occur due to burning out of the pre-conditioning exposure lamp.
[Cause]The filament of the fuse lamp is weaker than the designed value, thus a broken wire is likely to occurdue to production variation.
[Factory measure]To improve the durability of the pre-conditioning exposure lamp, the material comprising the filament ofthe fuse lamp and its wire diameter have been changed.
How to distinguish between the old and new parts: The last two digits of the lot number marked on thepre-conditioning exposure lamp PCB (FM5-5005) are “02”. (The last two digits of the lot numbers of theold part are “01”.)
- 1/1 -
Service parts
P.C.
440-3
440-3
Old
New
Old1
2
3
Old
Old
New
New
New
No. Description Part number Q’ty
1 → 0
0 → 1
1 → 0
0 → 1
FM5-5005-000
FM5-5005-020
FM5-0021-020
FM5-0021-030
Pre-con. exposure lamp PCB ass’y
Pre-con. exposure lamp PCB ass’y
Inter-change-ability
No Yes❈1
No YesPre-cond. exposure lamp ass’y(NP-A2S)Pre-cond. exposure lamp ass’y (NP-A2S)
LOCATION: PRE-CONDITIONING EXPOSURE LAMP ASSEMBLY
SUBJECT: PRE-CONDITIONING EXPOSURE LAMP BURN-OUT
No. : A2S-022
(G5-12E-022)
DATE: 23.-06.95