2
A-Sol Solenoid Valve A-Sol Series Standard Features Namur Mount Nema 4 / 4X / IP65 100% Duty Cycle Model A-SOL-N4-NMR 25 mm Orifice Area CV Factor 1.40 Specification 2 Rate Voltage Power Consumption Coil Insulation Eletrical Connection Duty Cycle Temperature (°F) AC 110V 50/60 HZ AC 220V DC 24V 4.8 W / 200 mA JISC3202-B Class DIN 46350 / Strain Relief Electrical Connector 100% (Continuous) 41 °F ~ 122 °F Options 24VAC, 110V, 220V, or 12 & 24 VDC Nema 7 Dual Coil Manual Override - CL I: Div. 1; GR. A, B, C, D - CL II: GR. E, F, G - NEMA: 4, 4X, 7C, 7D 5-way / 3-way, Two Position Spring Return Solenoid Valve 50/60 HZ 50/60 HZ (PG9 Cable) Working Pressure 22 - 116 PSI Maximum Temp./Pressure 202 °F / 174 PSI

A-Sol Solenoid Valve V3.pdfA-Sol Solenoid Valve A-Sol Series Standard Features Namur Mount Nema 4 / 4X / IP65 100% Duty Cycle Model A-SOL-N4-NMR 25 mm Orifice Area CV Factor 1.40 Specification

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: A-Sol Solenoid Valve V3.pdfA-Sol Solenoid Valve A-Sol Series Standard Features Namur Mount Nema 4 / 4X / IP65 100% Duty Cycle Model A-SOL-N4-NMR 25 mm Orifice Area CV Factor 1.40 Specification

A-Sol Solenoid ValveA-Sol Series

Standard FeaturesNamur Mount

Nema 4 / 4X / IP65100% Duty Cycle

Model

A-SOL-N4-NMR 25 mm

Orifice Area CV Factor

1.40

Specification

2

RateVoltage

PowerConsumption

CoilInsulation

EletricalConnection

Duty Cycle

Temperature(°F)

AC 110V50/60 HZ

AC 220V DC 24V

4.8 W / 200 mA

JISC3202-B Class

DIN 46350 / Strain Relief Electrical Connector

100% (Continuous)

41 °F ~ 122 °F

Options24VAC, 110V, 220V, or 12 & 24 VDC

Nema 7

Dual Coil

Manual Override

- CL I: Div. 1; GR. A, B, C, D- CL II: GR. E, F, G- NEMA: 4, 4X, 7C, 7D

5-way / 3-way, Two PositionSpring Return Solenoid Valve

50/60 HZ 50/60 HZ

(PG9 Cable)

WorkingPressure 22 - 116 PSI

MaximumTemp./Pressure 202 °F / 174 PSI

Page 2: A-Sol Solenoid Valve V3.pdfA-Sol Solenoid Valve A-Sol Series Standard Features Namur Mount Nema 4 / 4X / IP65 100% Duty Cycle Model A-SOL-N4-NMR 25 mm Orifice Area CV Factor 1.40 Specification

Nema 4 / 4X

INLINE INDUSTRIES, INC.9056 Garvey AvenueRosemead, CA 91770Tel: (626) 813-6188Fax: (626) 813-6186

Distributed by:

© 2010 Inline Industries. All rights [email protected] 1006.1

INLINEBALLVALVE . COM

PG9 CableStrain Relief Connector

0.94

Cylinder Port 2- O 5 Mounting Hole

0.63 1.

260.

16

1.57

1.10

2.91 1.77

2-FNPT 1/4" Exhaust

1-FNPT 1/4" Inlet

3.82

2.72

0.94

1.57

0.63 1.

260.

16

1.38

3.461.771.02

1.89

2.72

2- O 5 Mounting HoleCylinder PortCylinder Port

2-FNPT 1/4" Exhaust

1-FNPT 1/4" Inlet

A-SOL N4 NMR

Series Model Namur Type Operator Voltage

A-SOL - N4 / 4X NMR Namur TypeSolenoid

1 110V

Nema 4 Standard Coil -

N7Nema 7 Explosion

-

Proof Coil

5 Way Valve - 1 - Single Operator

2 - Double OperatorA24V - AC 24V 50/60 Hz110V - AC 110V 50/60 Hz220V - AC 220V 50/60 Hz12V - DC 12V24V - DC 24V

Nema 7

Manual Override

1.58

5.38