Rotex Solenoid Valve

Embed Size (px)

Citation preview

  • 7/25/2019 Rotex Solenoid Valve

    1/16

  • 7/25/2019 Rotex Solenoid Valve

    2/16

    3/2 DIRECT ACTING NAMUR SOLENOID VALVE

    0-10 barNC

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    30106

    30107 0-10 bar

    * Actuator spring side vent port.

    FLUID CONTROL SYSTEM

    CONNECTIONS

    TYPE

    30106,30107

    EXHAUST

    21

    INLET OUTLET

    4

    VALVE CODE

    ORIFICE

    3.0

    3.5

    4.0

    4.0

    30107

    4.0

    5.0

    7.0

    7.0

    ORIFICE

    1.8

    2.2

    2.5

    3.0

    30106

    kvlpm@1bar

    1.8

    2.5

    3.5

    4.0

    PRESSURE

    0 - 10

    0 - 8

    0 - 6

    0 - 4

    NBR

    S2

    S1

    S3

    VITON

    NEOPRENE

    EPDM

    SEAL

    Push & Turn

    M0

    MANUALOVERRIDE

    Nil

    BODY CODE

    SS316 B5

    Brass

    SS304

    Aluminium

    B2

    B4

    BODY &INTERNAL

    SUFFIXTYPE a b c d e

    NPTBSPSIZE

    PORT CONNECTION

    2R2G1/4

    ORDERING CODE

    FEATURESNormally Closed.Manual override push to operate & turn to lock is standard.Suitable for air, gases, water, oil, etc;Ideally suited for Spring Return Actuator on ON / OFF &

    Control duty.

    High pressure model can be supplied.Special version may be developed on request.

    Accessories for mounting the Solenoid Valve on the Actuatorare provided.

    Solenoid of any voltage rating/construction can be replaced atcustomers end.

    SOLENOID CODE

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NILManual Reset

    Ammonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low PowerCorrosive Environment

    Nuclear

    MR

    AM

    IS

    PC

    T6

    LWCO

    NP

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    2522

    M20 x 1.5

    52

    57

    38

    39

    64

    Specifications are subject to change without notice.

    DIMENSIONS

    ORDERING EXAMPLE

    Standard Version 30106-1.8-2G+24V-DC-22Special Version 30106PC-1.8-2G+24V-DC-35

    Need not be specified while ordering.

    EXHAUSTOUTLET

    3 5

    4

    3 5

    2

    1

    *

    Refer page no.14 for suggested application.

    kvlpm@1bar

    2

  • 7/25/2019 Rotex Solenoid Valve

    3/16

    0-10 barNC

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    30120

    30121 0-10 bar

    FLUID CONTROL SYSTEM

    CONNECTIONS

    TYPE

    30120,30121 21

    INLET OUTLETPILOTVENT

    6

    3/2 DIRECT ACTING WITH BUILTIN QUICK EXHAUST 5mm NAMUR SOLENOID VALVE

    * Actuator spring side vent port.

    VALVE CODE

    ORIFICE

    3.0

    3.5

    4.0

    4.0

    30121

    4.0

    5.0

    7.0

    7.0

    ORIFICE

    1.8

    2.2

    2.5

    3.0

    30120

    1.8

    2.5

    3.5

    4.0

    PRESSURE

    0 - 10

    0 - 8

    0 - 6

    0 - 4

    NBR

    S2

    S1

    S3

    VITON

    NEOPRENE

    EPDM

    SEAL

    Push & Turn

    M0

    MANUALOVERRIDE

    Nil

    BODY CODE

    SS316 B5

    Brass

    SS304

    Aluminium

    B2

    B4

    BODY &INTERNAL

    SUFFIXTYPE a b c d e

    NPTBSPSIZE

    PORT CONNECTION

    2R2G1/4

    ORDERING CODE

    Specifications are subject to change without notice.

    DIMENSIONS

    ORDERING EXAMPLE

    Standard Version 30120-2.2-2G+24V-DC-16Special Version 30121-4-2G-S1+220V-50Hz-35-H

    Need not be specified while ordering.

    SOLENOID CODE

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NILManual Reset

    Ammonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low Power

    Corrosive Environment

    Nuclear

    MR

    AM

    IS

    PC

    T6

    LW

    CO

    NP

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67

    Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    25

    22

    M20 x 1.5

    52

    57

    38

    39

    64

    FEATURES

    Inbuilt Quick Exhausting Mechanism for quick shutdown ofActuator.Exhaust Orifice 5mm(kv =12 lpm@1bar).Normally Closed.

    Manual Override push to operate & turn to lock is standard.Suitable for air, gases, water etc;

    Ideally suited for Spring Return Actuator on ON/OFF duty.Special version may be developed on request.

    Accessories for mounting the Solenoid Valve on the Actuatorare provided.

    Solenoid of any voltage rating/construction can be replaced atcustomers end.

    OUTLET EXHAUST

    3

    EXHAUST

    3 54 *

    Refer page no.14 for suggested application.

    kvlpm@1bar

    kvlpm@1bar

    3

    4

    5

    2

    1

    3

    6

  • 7/25/2019 Rotex Solenoid Valve

    4/16

    3/2 DIRECT ACTING HIGH ORIFICE, NAMUR, SOLENOID VALVE

    0-10 barNC

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    30318

    FLUID CONTROL SYSTEM

    ORDERING CODE

    Specifications are subject to change without notice.

    DIMENSIONS

    ORDERING EXAMPLE

    Standard Version 30318-5-2G+220V-50HZ-25-01Special Version 30319T6-7-2G-B4-S2+220V-50Hz-35-H

    Need not be specified while ordering.

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NILManual Reset

    Ammonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low Power

    Corrosive Environment

    Nuclear

    MR

    AM

    IS

    PC

    T6

    LW

    CO

    NP

    SPECIAL VERSIONFLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead, IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67

    Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    25

    22

    M20 x 1.5

    52

    57

    38

    39

    64

    0-10 bar30319

    FEATURES

    Normally ClosedManual Override push to operate & turn to lock is standardHigh Flow Valve, kv = 9lpm@1bar for fast opening & closing.Suitable for air, gases, water, etc;

    Ideally suited for Spring Return Actuator on ON / OFF & control duty.Exhaust purged to spring chamber.

    Special version may be developed on request.Accessories for mounting the Solenoid Valve on the Actuatorare provided.Solenoid of any voltage rating/construction can be replaced at

    customers end.

    CONNECTIONS

    * Actuator spring side vent port.

    TYPE

    30318, 30319 21

    INLET OUTLET EXHAUSTOUTLET

    3

    1

    4

    3

    2

    4 *

    Refer page no.14 for suggested application.

    4

    VALVE CODE

    SUFFIXTYPE a b c d e

    NPTBSPSIZE

    1/4" 2R2G

    PORT CONNECTIONPush & Turn

    NIL MO

    MANUAL OVERRIDENBR

    S2

    S1

    S3

    VITON

    NEOPRENE

    EPDM

    SEALBODY & INTERNAL

    BODY CODE

    Aluminium

    Brass B2

    SS304 B4

    SS316 B5

    ORIFICETYPE

    3031830319

    5.07.0

    kv(lpm@1bar)

    914

    SOLENOID CODE

  • 7/25/2019 Rotex Solenoid Valve

    5/16

    2-10 bar NC

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    31113

    3/2 INTERNAL / EXTERNAL PILOT OPERATED, POPPET TYPE,

    FLUID CONTROL SYSTEM

    5

    32105 0-10 bar

    NAMUR, SOLENOID VALVE

    ORDERING CODE

    Specifications are subject to change without notice.

    DIMENSIONS

    Standard Version 32105-6-2G+24V-DC-25Special Version 32105-6-2R-B5-S2+220V DC-50Hz-52-H

    ORDERING EXAMPLE

    Need not be specified while ordering.

    VALVE CODE

    SUFFIXTYPE a b c d e

    NPTBSPSIZE

    1/4" 2R2G

    PORT CONNECTIONPush & Turn

    NIL MO

    MANUAL OVERRIDE

    NBR

    S2S1

    S3

    VITON

    NEOPRENE

    EPDM

    SEALORIFICE

    6.0

    BODY & INTERNALBODY CODE

    Aluminium

    Brass B2

    SS304 B4

    SS316 B5SOLENOID CODE

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NILManual Reset

    Ammonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low Power

    Corrosive Environment

    Nuclear

    MR

    AM

    IS

    PC

    T6

    LW

    CO

    NP

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead, IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67

    Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    25

    22

    M20 x 1.5

    52

    57

    38

    39

    64

    FEATURES

    Air or Power failure to return.

    Normally Closed.High Flow Rate, kv=12 lpm@1bar, Fast Response Time.Suitable for air, gases, water, etc;Exhaust purged to spring chamber.

    Accessories for mounting the Solenoid Valve on the Actuatorare provided.

    Ideally suited for Spring Return Actuator on ON / OFF and control duty.

    (Recommended on regulation duty for system requiring air failure andpower failure safety).Special versions may be developed on request.Solenoid of any voltage rating/construction can be replaced atcustomers end.

    Photographed with Flameproof Solenoid

    CONNECTIONS

    * Actuator spring side vent port.

    TYPE OUTLETINLET

    31113 21 - 6

    PILOTINLET

    32105 21 6

    PILOT

    INTERNAL

    EXTERNAL

    PILOTVENT

    EXHAUST

    3

    3

    42

    31

    4 *

    4 *

    Refer page no.14 for suggested application.

    Pilot pressure minimum 3 baror > media pressure, whichever

    is higher.

    7

    OUTLET

  • 7/25/2019 Rotex Solenoid Valve

    6/16

    3/2 DIRECT ACTING REGULATING, NAMUR SOLENOID VALVE

    0-10 barNC

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    30136

    FLUID CONTROL SYSTEM

    VALVE CODE

    ORIFICE

    2.5

    3.0

    3.5

    4.0

    30136

    3.5

    4.0

    5.0

    7.0

    PRESSURE

    0 - 10

    0 - 8

    0 - 6

    0 - 4

    NBR

    S2

    S1

    S3

    VITON

    NEOPRENE

    EPDM

    SEAL

    Push & Turn

    NIL M0

    MANUALOVERRIDE

    BODY CODE

    SS316 B5

    Brass

    SS304

    Aluminium

    B2

    B4

    BODY &INTERNAL

    NPTBSPSIZE

    PORT CONNECTION

    2R2G1/4

    SUFFIXTYPE a b c d e

    CONNECTIONS

    TYPE OUTLET

    21

    INLET OUTLET

    30136

    EXHAUSTEXHAUST

    3 5

    * Actuator spring side vent port.

    ORDERING CODE

    Specifications are subject to change without notice.

    DIMENSIONS

    ORDERING EXAMPLE

    Standard Version 30136-3.0-2G+24V-DC-22Special Version 30136AM-3.0-2G-B5-S2+24V-DC-35-H

    Need not be specified while ordering.

    SOLENOID CODE

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NILAmmonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low Power

    Corrosive Environment

    Nuclear

    AM

    IS

    PC

    T6

    LW

    CO

    NP

    SPECIAL VERSIONFLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead, IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67

    Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    25

    22

    M20 x 1.5

    52

    57

    38

    39

    64

    FEATURES

    Air or Power failure to return.Unique 3 way design for locking.Single Acting spring return Actuator in multiple position

    required for modulating flow.Solenoid can be pulsed directly or through PID Controller.

    Suitable for air, Gases, water, oil, etc;Accessories for mounting the Solenoid Valve on the Actuatorare provided.

    Solenoid of any voltage rating/construction can be replaced atcustomers end.Special versions may be developed on request.

    1

    2 4

    53

    A B

    4 *

    Refer page no.14 for suggested application.

    kvlpm@1bar

    6

  • 7/25/2019 Rotex Solenoid Valve

    7/16

    3/3 DIRECT ACTING REGULATING, NAMUR SOLENOID VALVE

    0-10 barNC

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    30131

    FLUID CONTROL SYSTEM

    7

    VALVE CODE

    ORIFICE

    3.0

    3.5

    30131

    4.0

    4.5

    PRESSURE

    0 - 10

    0 - 8

    NBR

    S2

    S1

    S3

    VITON

    NEOPRENE

    EPDM

    SEAL

    Push & Turn

    NIL M0

    MANUALOVERRIDE

    BODY CODE

    SS316 B5

    BrassSS304

    Aluminium

    B2B4

    BODY &INTERNAL

    NPTBSPSIZE

    PORT CONNECTION

    2R2G1/4

    SUFFIXTYPE a b c d e

    CONNECTIONS

    TYPE OUTLET

    21

    INLET OUTLET

    30131

    EXHAUST

    34 *

    Specifications are subject to change without notice.

    DIMENSIONS

    Standard Version 30131-3.0-2G+24V-DC-22Special Version 30131CO-3.0-2G-B5-S2+24V-DC-38-H

    SOLENOID CODE

    ORDERING EXAMPLE

    Need not be specified while ordering.

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NILAmmonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low PowerCorrosive Environment

    Nuclear

    AM

    IS

    PC

    T6

    LWCO

    NP

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead, IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67Plug in, Pg9, IP 67

    Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    1425

    22

    M20 x 1.5

    52

    57

    38

    39

    64

    ORDERING CODE

    FEATURES

    Air or Power failure to retain position.Unique 3 way design for locking.Ideally suited for Single Acting spring return Actuator in

    multiple position required for modulating flow.Exhaust purged to spring chamber.Special versions may be developed on request.

    Solenoid can be pulsed directly or through PID Controller.Suitable for air, Gases, water, etc;

    Accessories for mounting the Solenoid Valve on the Actuator

    are provided.Solenoid of any voltage rating/construction can be replaced atcustomers end.

    4 2

    AB

    31

    Actuator spring side vent port.*

    Refer page no.14 for suggested application.

    kvlpm@1bar

  • 7/25/2019 Rotex Solenoid Valve

    8/16

    3/2 DIRECT ACTING ON / OFF / REGULATING, NAMUR SOLENOID VALVE

    0-10 barNC

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    30138

    FLUID CONTROL SYSTEM

    8

    CONNECTIONS

    TYPE

    21

    INLET OUTLET EXHAUSTOUTLET

    330138

    ORDERING CODE

    VALVE CODE

    ORIFICE

    2.5

    3.0

    30138

    3.5

    4.0

    PRESSURE

    0 - 10

    0 - 8

    NBR

    S2

    S1

    S3

    VITON

    NEOPRENE

    EPDM

    SEAL

    Push & Turn

    Nil M0

    MANUALOVERRIDE

    BODY CODE

    SS316 B5

    Brass

    SS304

    Aluminium

    B2

    B4

    BODY &INTERNAL

    SUFFIXTYPE a b c d e

    NPTBSPSIZE

    PORT CONNECTION

    2R2G1/4

    Specifications are subject to change without notice.

    DIMENSIONS

    ORDERING EXAMPLE

    Standard Version 30138-2.5+220V-50Hz-16Special Version 30138PC-2.5-B2-S2+110V-50Hz-35-H

    Need not be specified while ordering.

    SOLENOID CODE

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NIL

    Ammonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low Power

    Corrosive Environment

    Nuclear

    AM

    IS

    PC

    T6

    LW

    CO

    NP

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead, IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67

    Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    25

    22

    M20 x 1.5

    52

    57

    38

    39

    64

    FEATURES

    Most suited for stopping spring return actuator to mid positionset through limit switch.

    Air or Power failure to return.

    Direct Acting low cost.Solenoid of any voltage rating/construction can be replaced atcustomers end.Special versions may be developed on request.

    Solenoid can be operated directly or through PID Controller.Manual Override push to operate & turn to lock is standard.Suitable for air, gases, water, etc;

    Accessories for mounting the Solenoid Valve on the Actuatorare provided.Exhaust purged to spring chamber.

    2

    1

    3

    4

    A

    B

    Actuator spring side vent port.*

    4 *

    Refer page no.14 for suggested application.

    kvlpm@1bar

  • 7/25/2019 Rotex Solenoid Valve

    9/16

    5/3 DIRECT ACTING ON / OFF / REGULATING, NAMUR SOLENOID VALVE

    0-10 barNC

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    50401

    0-10 bar

    FLUID CONTROL SYSTEM

    9

    CONNECTIONS

    TYPE

    21

    INLET OUTLET

    4

    EXHAUSTOUTLET EXHAUST

    3 550401, 50402

    ORDERING CODE

    50402

    VALVE CODE

    ORIFICE

    3.0

    3.5

    4.0

    4.0

    50402

    4.0

    5.0

    7.0

    7.0

    ORIFICE

    1.8

    2.2

    2.5

    3.0

    50401

    kvlpm@1bar

    1.8

    2.5

    3.5

    4.0

    PRESSURE

    0 - 10

    0 - 8

    0 - 6

    0 - 4

    NBR

    S2

    S1

    S3

    VITON

    NEOPRENE

    EPDM

    SEAL

    Push & Turn

    Nil M0

    MANUALOVERRIDE

    BODY CODE

    SS316 B5

    Brass

    SS304

    Aluminium

    B2

    B4

    BODY &INTERNAL

    SUFFIXTYPE a b c d e

    NPTBSPSIZE

    PORT CONNECTION

    2R2G1/4

    Specifications are subject to change without notice.

    DIMENSIONS

    ORDERING EXAMPLE

    Standard Version 50401-2.2+220V-50Hz-15Special Version 50401-2.2-B2-S2+110V-50Hz-35-H

    SOLENOID CODE

    Need not be specified while ordering.

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NIL

    Ammonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low Power

    Corrosive Environment

    Nuclear

    AM

    IS

    PC

    T6

    LW

    CO

    NP

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead, IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67

    Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    25

    22

    M20 x 1.5

    52

    57

    38

    39

    64

    FEATURES

    Air or Power failure to retain position.Direct Acting, low cost alternative to 5 port valve.Most economical, best suited for Double Acting Rotary

    Actuator connected to either Ball Valve or Plug Valve onON / OFF & control duty.Solenoid can be operated directly or through PID Controller.

    Manual Override push to operate & turn to lock is standard.Suitable for air, gases, water, oil, etc;

    Accessories for mounting the Solenoid Valve on the Actuator

    are provided.Solenoid of any voltage rating/construction can be replaced atcustomers end.Special version may be developed on request.

    42

    1

    A B

    3 5

    Refer page no.15 for suggested application.

    kvlpm@1bar

  • 7/25/2019 Rotex Solenoid Valve

    10/16

    2-10 bar

    BIFUNCTIONAL

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    51424

    5/2 INTERNAL PILOT OPERATED, POPPET TYPE, NAMUR, SOLENOID VALVE

    FLUID CONTROL SYSTEM

    10

    ORDERING CODE

    DIMENSIONS

    Specifications are subject to change without notice.

    ORDERING EXAMPLE

    Standard Version 51424-6-2G+110V-50Hz-01Special Version 51424T6-6-2G-B5-S2+24V-DC-37-H

    Need not be specified while ordering.

    VALVE CODE

    SUFFIXTYPE a b c d e

    NPTBSPSIZE

    1/4" 2R2G

    PORT CONNECTIONPush & Turn

    NIL MO

    MANUAL OVERRIDENBR

    S2

    S1

    S3VITONNEOPRENE

    EPDM

    SEALORIFICE

    6.0

    BODY & INTERNALBODY CODE

    Aluminium

    Brass B2

    SS304 B4

    SS316 B5SOLENOID CODE

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NILManual Reset

    Ammonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low Power

    Corrosive Environment

    Nuclear

    MR

    AM

    IS

    PC

    T6

    LW

    CO

    NP

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead, IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67

    Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    25

    22

    M20 x 1.5

    52

    57

    38

    39

    64

    FEATURES

    Bifunctional Version.High Flow Rate, kv = 12 (lpm@1bar), Fast Response Time.Minimum operating pressure required.Suitable for air, gases, water etc.Ideally suited for Double Acting Actuator on ON / OFF &control Duty.Special versions may be developed on request.

    Poppet Design.Accessories for mounting the Solenoid Valve on the Actuatorare provided.Solenoid of any voltage rating/construction can be replaced atcustomers end.External pilot air operated available.

    Photograph with flameproof Solenoid

    INLET

    1

    EXHAUST

    2 34

    OUTLET

    5 6

    PILOTVENT

    TYPE

    51424

    PILOTINLET

    PILOT

    INTERNAL

    EXTERNAL1 2 34 5 652408

    CONNECTIONS

    0-10 bar52408

    4

    5

    2

    13

    Refer page no.15 for suggested application.

    Pilot pressure minimum 3 baror > media pressure, whicheveris higher.

    7

  • 7/25/2019 Rotex Solenoid Valve

    11/16

    5/2 INTERNAL PILOT OPERATED,POPPET TYPE, NAMUR,

    2-10 barBIFUNCTIONAL

    PRESSURETYPEPRESSURETYPETYPE PRESSURETYPE PRESSURE

    57412

    DOUBLE SOLENOID VALVE

    FLUID CONTROL SYSTEM

    ORDERING CODE

    11

    Specifications are subject to change without notice.

    DIMENSIONS

    Standard Version 57412-6-2G+110V-50Hz-01Special Version 57412-6-2G-B5+110V-50Hz-37-H

    SOLENOID CODE

    ORDERING EXAMPLE

    Need not be specified while ordering.

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    CLASS H

    CLASS C

    H

    C

    INSULATION

    NILAmmonia

    Intrinsically Safe

    Refinery

    Temp. Class T6

    Low Power

    Corrosive EnvironmentNuclear

    AM

    IS

    PC

    T6

    LW

    CONP

    SPECIAL VERSIONFLAMEPROOF (IP 67)

    TYPE

    3/4 ET NPT

    IIA, IIB

    IIC

    IIA, IIB (Side entry)

    IIC (Side entry)

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia (Side entry)

    JUNCTION BOX WITH LED, IP 67

    Cable entry

    FLYING CABLE, IP 67

    50

    55

    34

    36

    62

    51

    56

    35

    37

    63

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Flying Lead, IP 67

    Terminal Box 3/4 ET, IP 67

    Terminal Box 1/2NPT, IP 67

    Terminal Box M20 x 1.5, IP 67

    Plug in, Pg9, IP 67Plug in, Pg9, IP 67 with LED

    CODE

    01

    15

    16

    14

    2522

    M20 x 1.5

    52

    57

    38

    39

    64

    FEATURES

    Special versions may be developed on request.Poppet Design.

    Accessories for mounting the Solenoid Valve on the Actuatorare provided.Solenoid of any voltage rating/construction can be replacedat customers end.External pilot air operated available.

    Bifunctional Version.High Flow Rate, kv = 12(lpm@1bar), Fast Response Time.

    Minimum operating pressure required.Suitable for air, gases, water etc;Ideally suited for Double Acting Actuators on ON-OFF& control duty.

    CONNECTIONS

    INLET

    1

    EXHAUST

    2 34

    OUTLET

    5 6

    PILOTVENT

    TYPE

    57412

    4

    5

    2

    3

    1

    Refer page no.15 for suggested application.

    VALVE CODE

    SUFFIXTYPE a b c d e

    NPTBSPSIZE

    1/4" 2R2G

    PORT CONNECTIONPush & Turn

    NIL MO

    MANUAL OVERRIDE

    NBR

    S2

    S1

    S3VITONNEOPRENE

    EPDM

    SEALORIFICE

    6.0

    BODY & INTERNAL

    BODY CODE

    Aluminium

    Brass B2SS304 B4

    SS316 B5

  • 7/25/2019 Rotex Solenoid Valve

    12/16

    5/2 - 3/2 CONVERTIBLE, NAMUR SOLENOID VALVE

    FLUID CONTROL SYSTEM

    CONNECTIONS

    1 2

    OUTLETINLET OUTLET PILOT VENTEXHAUST EXHAUST

    3 5 7

    ORDERING CODE

    12

    * Actuator spring side vent port.

    Specifications are subject to change without notice.

    DIMENSIONS

    VALVE CODE

    FEATURES

    High flow NW 5.3, [email protected] lasting PTFE Seals.Temperature - 20 c to70 c.

    Lubrication is not necessary.Media :- Dry or lubricated air filtered to 50 .mSpool Design.Easily converted to 3/2.Special version s may be developed on request.

    Manual Override with lock facility.Double Solenoid version available.IP 67 Solenoid, Explosion proof version Solenoid on request.

    Corrosion resistance Anodized Aluminium.All voltage ratings available.Accessories for mounting the Solenoid Valve on the Actuatorare provided.Exhaust purged to spring chamber can be provided on request.

    12525

    10

    5 4 2

    5

    7

    1

    244

    3

    323

    404

    O5.55 5

    3/2 VERSION

    Turn Disk slot to 5

    5/2 VERSION

    Turn Disk slot to 4

    3-10 barBIFUNCTIONAL

    TYPE PRESSURE

    VAD213-NC

    TYPE PRESSURE TYPE PRESSURE

    Standard Version VAD213-NC-5.3-2G+24V-DCSpecial Version VAD213-NC-5.3-2G-B2-S2+24V-DC

    ORDERING EXAMPLE

    Need not be specified while ordering.

    42

    3 51

    4 *

    Refer page no.15 for suggested application.

    SOLENOID CODE

    CURRENTVOLTAGE

    12

    24

    48

    110

    125220

    240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    INSULATION

    NILIntrinsically Safe

    Refinery

    Corrosive Environment

    IS

    PC

    CO

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    Pg9

    IIA, IIB

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia

    Cable entry

    FLYING CABLE, IP 6750

    62

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Plug in, Pg9, IP 67

    CODE

    SUFFIXTYPE a b c d e

    NPTBSPSIZE1/4" 2R2G

    PORT CONNECTION

    LockableNIL MO

    MANUAL OVERRIDE

    NBR+P.T.F.E.

    S2

    S1

    S3

    VITON+P.T.F.E.

    NEOPRENE+P.T.F.E.

    EPDM+P.T.F.E.

    SEALORIFICE

    5.3

    BODY & INTERNAL

    BODY CODEAluminium

    Brass B2

    SS304 B4

    SS316 B5

  • 7/25/2019 Rotex Solenoid Valve

    13/16

    5/2 - 3/2 CONVERTIBLE, WITH INTEGRAL FLOW CONTROL

    FLUID CONTROL SYSTEM

    CONNECTIONS

    1 2

    OUTLETINLET OUTLET PILOT VENTEXHAUST EXHAUST

    3 5 7

    13

    ORDERING CODE

    * Actuator spring side vent port.

    Specifications are subject to change without notice.

    DIMENSIONS

    FEATURES

    High flow NW 5.3, Kv=10lpm@1bar.

    Long lasting PTFE Seals.

    Temperature - 20 c to70 c.Lubrication is not necessary.

    Media :- Dry or lubricated air filtered to 50 m

    Spool Design.

    Easily converted to 3/2.

    All voltage ratings available.

    Manual Override with lock facility.

    Double Solenoid version available.

    IP 67 Solenoid, Explosion proof version Solenoid on request.Corrosion resistance Anodized Aluminium.

    Exhaust purged to spring chamber can be provided on request.

    Accessories for mounting the Solenoid Valve on the Actuator are provided.

    Highly sensitive flow regulation, for achieving very slow to full speed operation

    of the Actuator.

    NAMUR SOLENOID VALVE

    VALVE CODE

    SUFFIXTYPE a b c d e

    NPTBSPSIZE1/4" 2R2G

    PORT CONNECTION

    LockableNIL MO

    MANUAL OVERRIDE

    NBR+P.T.F.E.

    S2

    S1

    S3

    VITON+P.T.F.E.

    NEOPRENE+P.T.F.E.

    EPDM+P.T.F.E.

    SEALORIFICE

    5.3

    BODY & INTERNAL

    BODY CODEAluminium

    Brass B2

    SS304 B4

    SS316 B5

    3/2 VERSION

    Turn Disk slot to 5

    5/2 VERSION

    Turn Disk slot to 4

    3-10 bar

    BIFUNCTIONAL

    PRESSURETYPEPRESSURETYPETYPE PRESSURE

    VAD213-NC-FC

    12525

    10

    5 4 2

    5

    7

    1

    244

    3

    323

    404

    O5.55 5

    SOLENOID CODE

    CURRENTVOLTAGE

    12

    24

    48

    110

    125

    220240

    50Hz

    60HZ

    DC

    a cb

    CLASS F

    INSULATION

    NILIntrinsically Safe

    Refinery

    Corrosive Environment

    IS

    PC

    CO

    SPECIAL VERSION

    FLAMEPROOF (IP 67)

    TYPE

    Pg9

    IIA, IIB

    INTRINSICALLY SAFE IP 67

    NOTE : voltage 24V DC only

    E Ex ia

    Cable entry

    FLYING CABLE, IP 67

    50

    62

    CONSTRUCTION

    GENERAL PURPOSE / WEATHERPROOF

    TYPE

    Plug in, Pg9, IP 67

    CODE

    Standard Version VAD213-NC-FC-5.3-2G+220V-50HzSpecial Version VAD213-NC-FC-5.3-2G-B4+24V-DC

    ORDERING EXAMPLE

    Need not be specified while ordering.

    42

    3 5

    1

    4 *

    Refer page no.15 for suggested application.

  • 7/25/2019 Rotex Solenoid Valve

    14/16

    APPLICATION

    FLUID CONTROL SYSTEM

    14

    ON - OFF & control duty for Spring Return ActuatorAir & Power failure to close.

    Type : 30106, 30107

    Type : 30120, 30121

    ON - OFF service for Spring Return Actuator.Air & Power failure to close.

    Type : 30318, 30319

    ON - OFF & control duty for Spring Return ActuatorAir & Power failure to close.

    Exhaust purged to spring chamber.

    4

    3

    2

    1

    Type : 31113

    ON - OFF & control duty for Spring Return ActuatorAir & Power failure to close.

    Exhaust Purged to spring chamber.

    42

    31

    ON - OFF & control duty for Spring Return ActuatorExhaust Purged to spring chamber.

    Air & Power failure to close.

    Type : 32105

    Type : 30136

    Inching application.Air & Power failure to close.

    Type : 30131

    Inching application.

    Air & Power failure to stayout.Exhaust Purged to spring chamber.

    Scheme for 3 position Actuator in sequence full open - part open - closeAir & Power failure to close.

    Exhaust Purged to spring chamber.

    Type : 30138

    A

    B

    ACTION

    OFFOFFReturntosprin

    gposition.

    ON

    ON

    Open

    OFFON

    Canstoptoint

    ermediate

    A

    B

    ACTION

    ON

    OFFOpen

    OFFOFFCanstoptointermediate

    position

    A

    B

    ACTION

    OFFOF

    FReturntospring

    position.

    ON

    AN

    YOpen

    OFFON

    Canstoptointermediate

    4

    3 5

    2

    1

    1

    2 4

    53

    A B

    4

    3

    2

    71

    2

    1

    3

    4

    A

    B

    Specifications are subject to change without notice.

    PARTIAL OPEN

    FULL OPEN

    COMMON

    4 2

    AB

    31

    The Solenoid Valve can be used for other applications also.To ensure correct orientation of the Solenoid Valve, fix M5 grub screw on the Actuator, projecting 2~3 mm,at one of the M5 hole, other than the one used for mounting the Solenoid Valve.

    i

    i

    4

    5

    2

    1

    3

    6

  • 7/25/2019 Rotex Solenoid Valve

    15/16

    APPLICATION

    FLUID CONTROL SYSTEM

    15

    Type : VAD213 - NC

    Type : VAD213-NC-FC

    42

    3 5

    1

    5/2 Mode (Turn Disk slot to 4) 3/2 Mode (Turn Disk slot to 5)

    42

    3 51

    Type : 50401

    Inching application for Double Acting Actuator. (Typically for Terminal Automation)Suitable for Ball valve & plug valve only. (Unsuitable for Butterfly Valve & Dampers)

    Air & Power failure to stayput.

    ON - OFF duty for Double Acting ActuatorPower failure to close. Air failure to stayput.

    Type : 51424 Type : 52408

    ON - OFF & control duty for Double Acting ActuatorAir & Power failure to close.

    Type : 57412

    ON - OFF duty for Double Acting ActuatorPower failure to stayout.

    4

    5

    2

    3

    1A

    B

    ACTION

    OFFOFFCanstoptoin

    termediate

    position.

    ON

    OFFOpen

    42

    1

    A B

    3 5

    4

    5

    2

    13

    4

    5

    2

    1

    73

    NRV

    Volume Tank

    5/2 Mode (Turn Disk slot to 4) 3/2 Mode (Turn Disk slot to 5)

    42

    3 5

    1

    42

    13 5

    Specifications are subject to change without notice.

    The Solenoid Valve can be used for other applications also.To ensure correct orientation of the Solenoid Valve, fix M5 grub screw on the Actuator, projecting 2~3 mm,at one of the M5 hole, other than the one used for mounting the Solenoid Valve.

    i

    i

  • 7/25/2019 Rotex Solenoid Valve

    16/16

    ROTEXMANUFACTURERS & ENGINEERS PVT. LTD

    Manpada Road, Dombivli (E)-421204

    Maharashtra, INDIA

    Ph. : +91 251 2871033 / 2871390 / 2871196 /

    2871989 / 2870890 / 2870663

    Fax : +91 251 871191 / 870864

    E-mail : [email protected]

    ROTEX AUTOMATION LIMITED

    UNIT 1

    987/11, G.I.D.C. Makarpura,

    Vadodara-390010, Gujarat

    Ph. : +91 265 2638136 / 2638795 / 46

    Fax : +91 265 2638130

    E-mail : [email protected]

    UNIT 2

    C-1 B/1501, 4 & 5, G.I.D.C.

    Vithal Udyongnagar, Gujarat-388121

    Ph. : +91 2692 236224 / 236292 /

    236399

    Fax : +91 2692 236442

    E-mail : [email protected]