64
A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Embed Size (px)

Citation preview

Page 1: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

A Dual Elevator Meteorological System at the

Cooper Nuclear Station

Jim Holian/Russ SoutherlandSAIC

June 2005 NUMUG Meeting

Page 2: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

• 1982 design • Single sensors on 100-meter tower - WS,

WD, T, Delta-T (10-, 60-, and 100-meter)• Single elevator system• 10-meter backup tower• Precipitation on shelter roof• PDP 11/34 computer system (in Plant)

Existing Meteorological System (9/04)

Page 3: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 4: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

• Difficulty achieving 90% data recovery• I&C delay repairing system• Increased sensor/wiring failures• Single point of failure – PDP 11/23• No viable independent backup system• Lost data during power failures• System becoming labor intensive ($$$$)

Problems

Page 5: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Old Single Carriage

Page 6: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

• A viable, independent backup system with independent elevator system, allowing one system to be taken out of service without impacting the other.

• Averaging performed in the MET shelter

• Primary and secondary storage of digital data in the MET shelter as well as on PMIS.             

CNS Met Upgrade Requirements

Page 7: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

• Off-the-shelf commercial-grade equipment with the averaging software included within the unit, eliminating the need to develop and maintain software and associated quality control on the PMIS.

• Real-time meteorological data validation based on meteorological principles, CNS site conditions, and climatology

• Eliminate strip chart recorders            

CNS Met Upgrade Requirements

Page 8: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

• Automatic and immediate substitution of data whether a single sensor fails, is impacted by meteorological conditions, or the entire System A or B is out of service.

• Real-time meteorological data validation based on meteorological principles, CNS site conditions, and climatology

• UPS system in place to maintain power to the MET instruments during short-term station blackout             

CNS Met Upgrade Requirements

Page 9: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Systems A and B 10, 60, and 100 meter wind speed and direction 3 Delta-ts (60m-10m, 100m-10m, 100m-60m) 10, 60, and 100 meter temperatures

System A only 10 meter dew point Station Pressure Precipitation 

Meteorological Parameters

Page 10: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

System A Climatronics F460 Wind speed and Direction Sensors Climatronics Temperature Sensors Tower Systems Elevator Climatronics Dew Point Sensor Climatronics Tipping Bucket Rain gauge with Wind Shield Campbell Scientific 23X Micro DataloggersClimatronics Pressure Sensor

Meteorological Equipment

Page 11: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

System B Met One 50.5 Sonic Wind speed and Direction Sensors Climatronics Temperature Sensors Tower Systems Elevator Campbell Scientific 23X Micro Dataloggers

Meteorological Equipment

Page 12: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

• Two Elevator Systems on same face (biggest design challenge)

• Validation without elimination

• Reduce false 9 out of data

• Include onsite conditions/climatology

Dual System Design Basis

Page 13: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

•Produce a valid data set that is the “best of”

•Reduce manual labor

•Decrease maintenance costs (i.e. Sonic)

•Independently shut down individual sensors

Dual System Design Basis (cont’d)

Page 14: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 15: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 16: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

• Detects the presence of wind direction shear between tower levels

• Identifies differences in the data attributable to tower interference

• Recognizes light and variable winds

• Identifies wind speed cup/threshold problems before they become obvious

Site-Specific Software

Page 17: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Site-Specific Software (cont’d)

•Recognizes delta-t differences attributed to sunrise/sunset/precipitation onset

• Identifies aspirator trips/fluctuations

• Identifies problems associated with temperature/dew point/precipitation interactions

•Ability to turn off any sensor remotely

Page 18: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Tower Interference

Page 19: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 20: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 21: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 22: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 23: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 24: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

0-3 Good data, best of both Systems A and B

4-6 Requires closer review because system validation was limited or non-existent

 7-8 Requires intense scrutiny because data failed

system validation

9 Bad or missing data

Validity Flags Summary

Page 25: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Construction/InstallationBrownville, Nebraska

(Sept-Oct 04)

Wind, wind, and more wind!!!

Page 26: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 27: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 28: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Old Winch Box

Page 29: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 30: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 31: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 32: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Old Elevator Box

Page 33: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 34: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 35: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 36: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 37: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 38: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 39: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 40: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 41: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 42: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 43: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 44: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 45: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Old Rack

Page 46: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 47: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 48: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 49: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

Dual Monitoring System

Met Shelter Onsite

Page 50: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 51: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 52: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 53: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 54: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 55: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 56: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 57: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 58: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 59: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 60: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 61: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 62: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 63: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting
Page 64: A Dual Elevator Meteorological System at the Cooper Nuclear Station Jim Holian/Russ Southerland SAIC June 2005 NUMUG Meeting

• Dual elevator installed on same tower face• Totally independent dual meteorological monitoring system • System operational since 10/26/04• No problems to date – system performing as designed.• Automatic data validation – (interesting comparisons between standard/sonic sensors – future NUMUG paper!)

CNS Dual System Summary