M A K E I T S I M P L E
A Conical Connection Implant
P.16-17
P.18-19
P.20-21
P.23
P.14-15
P.12-13
P.11
P.10
P.9
P.8
P.6-7
P.4-5
P.22
P.24-25
MIS Warranty:
MIS exercises great care and effort in maintaining the superior quality of its products. All MIS products are guaranteed to be free from defects in material and workmanship. However, should a customer find fault with any MIS product after using it according to the directions, the defective product will be replaced.
Warning: Products should be used by licensed dentists only.
Introduction
Advantages
Implant range
Ø3.75mm Implants
Ø4.20mm Implants
Ø5mm Implants
Drilling procedures
Surgical kit
DSM
Restorative components
Success factors
Keys & Adapters
Insertion System
Packaging
Table of contents.
4.
© MIS Corporation. All rights reserved.
Always dedicated to the development of innovative
products and technologies, MIS' scientists and engineers
conduct continuous laboratory and field studies in
collaboration with prestigious universities and dental
research institutes. C1 is the innovative result of an
extensive research and development process, offering a
unique combination of surgical and restorative benefits.
6.
Advantages.
C1 conical connection implant
All C1 implants, superstructures and tools are color coded to simplify an immediate identification of their platform.
Advantages.
Yellow - indicates a narrow platform
Green - indicates a wide platform
Purple - indicates a standard platform
SurfaceThe surface roughness and micro-morphology combine sand blasting and acid etching. MIS' notable surface technology has provided millions of patients and clinicians with excellent osseointegration results and a long lasting clinical success.
The C1 implantC1 implant benefits from a conical connection with an anti-rotation, six position, cone index. The absolute implant-abutment fastening and the definite seal offered by the conical connection minimize micro-movements and preserve the bone.
Conical shapeWith its conical, root-shaped geometry and a unique thread design, C1 ensures a superior primary stability and offers the ultimate choice for a wide range of clinical cases and loading protocols ▪ Its root-shaped design makes C1 ideal for narrow spaces, restricted by adjacent teeth or implants.
Two spiral channels and domed apexThe two spiral channels at the apical end of the implant, coupled with its self tapping design enable mild direction refinement during the initial stages of insertion ▪ A domed apex allows a safer procedure.
Platform switchingThe C1 system incorporates platform switching by design, allowing the perfect environment for soft-tissue growth and minimizing bone resorption.
Micro ringsMicro rings (0.1x0.3) on the implant’s neck improve the BIC (Bone to Implant Contact) at the crestal zone.
Dual threadA dual thread design increases BIC, reinforcing osseointegration for long lasting clinical success ▪ The overall insertion rate of C1 is 1.5mm per revolution ▪ A self-tapping design and mild bone-compression properties enhance its primary stability.
CC1-00375
CS-HS375CS-HS475CS-HS575CS-HS675
3/4/5/6mm
Ø 4mm
CS-HA375CS-HA475CS-HA575CS-HA675
3/4/5/6mm
Ø 4.4mm
CC1-00500
16mm
16mm
11.50mm
11.50mm
13mm
13mm
8mm
8mm
10mm
10mm
Ø3.75mm
Ø5mm
Ø4.20mm
8.
C1-10375 C1-13375 C1-16375
C1-10420 C1-11420 C1-13420 C1-16420
C1-11375C1-08375
C1-08420
C1-08500 C1-10500 C1-11500 C1-13500 C1-16500
CW-HS350CW-HS450CW-HS550
3/4/5mm
Ø 5mm
3/4/5mm CW-HA350CW-HA450CW-HA550
Ø 5.8mm
Standard PlatformScrew type implant range
Implants cover screw and healing caps.Available in heights: 3,4,5,6mm
Length
Type
Length
Type Implants cover screw and healing caps.Available in heights: 3,4,5mm
Wide PlatformScrew type implant range
Ø 3.10
Ø 3.75
Ø3
Ø 3.60
Ø3.15
1200-1500
900-1200
Ø1.90 Ø3 Ø3.75Ø2.40 Ø2.40
500-700 15-25
Ø3 Ø3.60
200-400
Ø3
C1-08375
C1-16375
C1-10375
C1-11375
C1-13375
Ø3.75mm
Ø3.75mm
Single-use final drill A specially designed final drill for 8mm, 10mm, 11.50mm, 13mm and 16mm implants is supplied with every implant, allowing a short, sterile and safe drilling procedure. This final drill should not be used in type 4 bone.
Standard PlatformCatalog No. Dimensions
Ø 3.75mmlength 8mm
Ø 3.75mmlength 10mm
Ø 3.75mmlength 13mm
Ø 3.75mmlength 16mm
Ø 3.75mmlength 11.50mm
Implant Procedure
Drilling Speed (RPM)
Diameter
For bonetype 1,2&3
Final drill
* The implant package includes: a cover screw, temporary cylinder and a final drill
The drilling sequence is demonstrated by a 13mm implant.
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
Do not use the final drill for bone type 4
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
Ø4.20mm
10.
Ø3.50
Ø4
Ø 3.60
Ø 4.20
Ø3.15
C1-08420
C1-16420
C1-10420
C1-11420
C1-13420
Ø4.20mm
1200-1500
900-1200
Ø2.40 Ø3Ø1.90 Ø2.40
500-700
Ø3.50 Ø3.50
400-700
Ø3.50Ø4
200-400
Ø4.20
15-25Drilling Speed (RPM)
Diameter
Ø 4.20mmlength 8mm
Ø 4.20mmlength 10mm
Ø 4.20mmlength 13mm
Ø 4.20mmlength 16mm
Ø 4.20mmlength 11.50mm
For bonetype 1,2&3
Final drill
Implant Procedure
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
Standard PlatformCatalog No.
Single-use final drill A specially designed final drill for 8mm, 10mm, 11.50mm, 13mm and 16mm implants is supplied with every implant, allowing a short, sterile and safe drilling procedure. This final drill should not be used in type 4 bone.
Dimensions
The drilling sequence is demonstrated by a 13mm implant.
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
Do not use the final drill for bone type 4
* The implant package includes: a cover screw, temporary cylinder and a final drill
Ø4.10 Ø 4.90
200-400
Ø5
15-25
Ø4
400-600
1200-1500
900-1200
Ø2.40 Ø3 Ø3.50Ø2.40Ø1.90
500-700
400-700
Ø5mm
C1-08500
C1-16500
C1-10500
C1-11500
C1-13500
Ø 5
Ø 4.50Ø 4.10
Ø 4.90
Ø4
Ø5mm
Ø4
Drilling Speed (RPM)
Diameter
For bonetype 1,2&3
Final drill
Implant Procedure
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
Wide Platform
Ø 5mmlength 8mm
Ø 5mmlength 10mm
Ø 5mmlength 13mm
Ø5mmlength 16mm
Ø 5mmlength 11.50mm
Catalog No. Dimensions
Single-use final drill A specially designed final drill for 8mm, 10mm, 11.50mm, 13mm and 16mm implants is supplied with every implant, allowing a short, sterile and safe drilling procedure. This final drill should not be used in type 4 bone.
The drilling sequence is demonstrated by a 13mm implant.
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
Do not use the final drill for bone type 4
Titanium Alloy Ti 6Al 4V ELISand Blasted and Acid-Etched
* The implant package includes: a cover screw, temporary cylinder and a final drill
Ø3.7
5Ø
4.20
Ø5
C1 IMPLANT
P
ILOT
DRILL
Ø2.4
0mm
PILOT DRILL Ø2.40mm
B
ODY
TRY
IN Ø
2.40m
m BODY TRY IN Ø2.40mm
TW
IST
DRILL
3m
m
TWIST DRILL 3mm
B
ODY
TRY
IN Ø
3mm
TWIST DRILL 3.50mm
TWIST DRILL 3.50mm
FIN
AL D
RILL
BODY TRY IN Ø
3.5mm
BODY TRY IN Ø4mm
FINAL DRILL
SPAD
E / M
ARKI
NG D
RILL
Ø1.9
0mm
SPADE / MARKING DRILL Ø1.90m
m
FINAL DRILL
TWIST DRILL 4mm
TWIST DRILL 3mm
BODY TRY IN Ø2.40mm
PILOT DRILL Ø2.40mm
SPADE / MARKING DRILL Ø1.90mm
12.
Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.
Initial surgical steps are common for all implant diameters. Additional steps are required as the implant's diameter grows.
DrillingProcedures.
Ø3.7
5
Ø4.20
Ø5
C1 IMPLANT
P
ILOT
DRILL
Ø2.4
0mm
PILOT DRILL Ø2.40mm
B
ODY
TRY
IN Ø
2.40m
m BODY TRY IN Ø2.40mm
TW
IST
DRILL
3m
m
TWIST DRILL 3mm
B
ODY
TRY
IN Ø
3mm
TWIST DRILL 3.50mm
TWIST DRILL 3.50mm
FIN
AL D
RILL
BODY TRY IN Ø
3.5mm
BODY TRY IN Ø4mm
FINAL DRILL
SPAD
E / M
ARKI
NG D
RILL
Ø1.9
0mm
SPADE / MARKING DRILL Ø1.90m
m
FINAL DRILL
TWIST DRILL 4mm
TWIST DRILL 3mm
BODY TRY IN Ø2.40mm
PILOT DRILL Ø2.40mm
SPADE / MARKING DRILL Ø1.90mm
STANDARD
WIDE
Ø1.90 Ø2.40 Ø3Ø2.40 Ø3 Ø3.50 Ø4Ø4Ø3.50
Procedure Tools Description.
Spade / marking drill Ø1.90mm
Body try in Ø2.40mm for tapered implant procedure
Body try in Ø3mm for tapered implant procedure
Twist drill 3mm, external irrigation
Twist drill 3.50mm, external irrigation
Twist drill 4mm, external irrigation
Final drill
Body try in Ø3.50mm for tapered implant procedure
Body try in Ø4mm for tapered implant procedurePilot drill Ø2.40mm
14.
MK-0044
MT-GDN33
MT-GDN50
MT-BTT24
MT-BTT30
MT-BTT35
MT-RI030
MT-SMD10
MT-TDN30
MT-TDN35
CT-SSI10 CT-SLI10 CT-SDI01
MT-P2408
MT-P2410
With external irrigation drills
Advanced Surgical Instrument Kit.
MT-TDN19
CT-WSI10 CT-WLI10CT-WDI01MT-BTT40 MT-BTT45MT-BTT45 MT-BTT50
MT-SM005
MT-DE001
MT-SHA10
MT-PP240
MT-P2411
MT-P2413
MT-P2416
MT-LM005
MT-SRA10
MT-TDN40
MT-TDT45
MT-TDN50
13.
.
MECHANICAL STABILITY BIOLOGICAL STABILITY
Thanks to a unique drilling methodology,
the implant's geometric design enables a moderate compression of the bone at the top 2/3 of its body. This congestion, enabled by a distinctive conical shaped final drill, provides an immediate and
prolonged mechanical primary stability.
A n e n h a n c e d secondary biological stability
is achieved by integration of the implant's geometry, morphology and
a differential drilling approach. The compartments formed between the implant's threads at the bottom 1/3 of the cavity, generate an ideal habitat
for sustainable bone growth leading to an accelerated
osseointegration.
The Dual Stability Mechanism
(DSM) provided by C1 is based on an integrative development involving the implant’s macro and micro structure as well as a unique differential drilling methodology. C1’s conical design enables
moderate compression of the bone at the coronal 2/3 of the implant's body, providing an immediate mechanical primary stability, while the apical 1/3 of the implant is designed to enable rapid bone growth aimed to minimize stability loss during the first weeks after surgery.
The compartments formed between the threads are a result of the differential drilling approach, which prevents bone compression at the apical section of the implant. The result is an ideal habitat for accelerated and sustainable bone growth and osseointegration, establishing the
Thanks to a unique drilling methodology, the implant's geometric
design enables a moderate compression of the bone at the top 2/3 of its body. This compression, enabled by a distinctive conical shaped final drill, provides
an immediate and prolonged mechanical primary stability.
16.
MECHANICAL STABILITY BIOLOGICAL STABILITY
Thanks to a unique drilling methodology,
the implant's geometric design enables a moderate compression of the bone at the top 2/3 of its body. This congestion, enabled by a distinctive conical shaped final drill, provides an immediate and
prolonged mechanical primary stability.
A n e n h a n c e d secondary biological stability
is achieved by integration of the implant's geometry, morphology and
a differential drilling approach. The compartments formed between the implant's threads at the bottom 1/3 of the cavity, generate an ideal habitat
for sustainable bone growth leading to an accelerated
osseointegration.
implant’s long term biological stability. The DSM mechanism combines benefits of both high primary stability and an accelerated osseointegration process, abridging the way to complete long term stability.
An enhanced secondary biological stability is achieved by
integration of the implant's geometry, morphology and a differential drilling
approach. The compartments formed between the implant's threads at the bottom 1/3 of the cavity generate an ideal habitat for sustainable bone
growth leading to an accelerated osseointegration.
18.
Stoppers
Four sleeves for each diameter in 8, 10, 11.5 and 13mm lengths, color coded according to drills
Box
The tray can be taken out of the box for better convenience
Scale
Teflon OUT Insert
Teflon IN Insert
Simple.
Quick, easy assembly
Kit Contents Ø2.80 stoppers(for Ø3.75mm implants)
Ø3.20 stoppers(for Ø4.20mm implants)
Easy.Color coding for a quick identification of sleeve diameter
Safe. Safe drilling to desired depth
Clear. Clearly arranged depth sleeves for 8 to13mm for two diameters, Ø2.8 and Ø3.2mm
Following the use of MIS' length based pilot drills, the C1 Standard Platform Stoppers Kit ensures drilling to the exact desired depth. The kit includes the most commonly used lengths: 8, 10, 11.5 and 13mm.
Drill Stoppers Kit Standard Platform.
MK-BC101
8mm10mm
11.5mm13mm
MK-CDS08 MK-CDS10
MK-CDS11 MK-CDS13
Simple.
Quick, easy assembly
For 8mm implants For 10mm implants
For 11.5mm implants For 13mm implants
Kit Contents
Scale
Box
Stoppers
The tray can be taken out of the box for better convenience
Five sleeves 3.0, 3.5, 4, 4.5 and 5mm diameters, color coded according to drills
Desireddrilling depth
Teflon OUT Insert
Teflon IN Insert
Easy.Color coding for a quick identification of sleeve diameter
Safe. Safe drilling to desired depth
Clear. Clearly arranged depth sleeves for Ø2.8mm to Ø5mm diameter drills
Following the use of MIS' length based pilot drills, the C1 Drill Stoppers Length Kits enable a safe and easy drilling to the exact desired depth. MIS offers 4 different kits in lengths of: 8, 10, 11.5 and 13mm.
Drill Stoppers Kits Depth Based.
Advantages.
20.
Micro Structure - Surface Morphology
The surface roughness and microgeometry is achieved by sand blasting and acid-etching. A larger surface area increases bone-to-implant contact (BIC), resulting in a long term clinical success.
A high success rate is achieved through a combination of advanced geometric design and our well established surface morphology.
Success.
20
15
10
5
0
Microgram
Implant
Jerusalem, Israel, IADRAugust 03, 2004
Hebrew University
Adsorption of Serum Protein to Modified Titanium SurfacesM.N. Sela, L.Badihi, G.Rosen, D.Kohavi and D. Steinberg
The use of Titanium (Ti) implants is a novel clinical procedure in dentistry. The adsorption of biological molecules to the implant’s surface triggers a sequence of events that may determine the outcome of this procedure. Clinical data suggests that modified Ti surfaces play an important role in the success or failure of the implant. Objective: the purpose of this study was to investigate the interaction between Ti implants with different surface properties and serum proteins, in order to find the optimal implant surfaces which may improve the Osseointegration process and implant intake.
Materials & Methods: Six mm in diameter Ti disks with two types of surface modifications were compared: Machined and Sandblast plus Acid-Etched. The disks were coated with mixtures of Human Serum Albumin conjugated with fluorescein (HAS-FITC).
Following incubation, the coat was removed from the disks by SDS. A Confocal Scanning Laser Microscope was used to visualize and measure the HAS-FITC coat and the degree of protein removal from the Ti surfaces.
Results: The Confocal Microscope images revealed a significantly higher amount of HAS-FITC coat on the rough disks, as compared with the machined disks. Furthermore, under similar experimental conditions, less HAS-FITC could be removed from the rough disks than from the machined disks.
Conclusions: Absorption of albumin to the rough treated Ti surface is both qualitatively and quantitatively far more intense, as compared with the machined surfaces. Further studies of the chemical and physical characterization of the modified Ti surfaces are underway. Moreover, additional serum proteins, as well as oral microorganisms, are being examined for their interactions with the modified Ti surfaces.
Albumin
IGG
Fibronectin
Fibrinogen
Machine
Machine
MIS surface
22.20.22.
MT-SRA10
CT-SLI10
CT-SSI10
MT-SHA10
MT-LM005
MT-SM005
Squ
are
conn
ectio
n to
rat
chet
ada
pter
Han
d w
renc
h sq
uare
con
nect
ion
Long
mot
or a
dapt
er fo
r 0.
05"
hex.
Sho
rt m
otor
ada
pter
for
0.05
" he
x.
Long
inse
rtio
n to
ol, S
P
Sho
rt in
sert
ion
tool
, SP
The C1 mountless implants have their own placement tools. These tools are designed to facilitate quick and reliable implant procedures.
Keys & Adapters.
Standard platform tools shown
13
2
1.
2.
3.
20.
Insertion tool in hand key adapter
Insertion tool for motor
Insertion tool in ratchet adapter
The unique "3 in One" key system minimizes the number of tools in the surgical kit and maximizes flexibility for the user.
"3 in One" Insertion System.
Insertion Options.
24.
Each C1 implant comes with sterilized components for multiple clinical scenarios.
Package Contents.
Cov
er S
crew
Fina
l Dril
l
Insi
de T
ube
Out
side
Tub
e
Impl
ant
13.
Tem
pora
ry C
ylin
der
Following the "Make It Simple" philosophy, MIS is proud to be the first to include a comprehensive tool set which includes: a single use final drill, a cover screw and a temporary cylinder with every C1 implant, meeting all your clinical needs.
12.
Packaging.
Easy pull tab
Implant identification markings
Logical storage
The easily identified pull tab facilitates quick and easy opening during surgery.
The implant's package allows a convenient logical arrangement in its drawer and an immediate identification of the contents.
Quick identification of implant's size and length. A sticker on top of the box, specifies implant's diameter, length and platform size.
Providing a simple indication identification of implant type, length and diameter, the C1 package is well designed for ease of use during surgery.
A double packing system ensures sterilization and safety. Packages are designed for ease of use during surgery and for use with surgical gloves.
Implant diameter & platform indicationThe outer tube is color-coded indicating the implant's platform. The numeric indication specifies the implant's diameter and length.
Platform code Prosthetic platform indicationProsthetic components are marked by specific colors, representing their platforms.
® All rights reserved. No part of this publication may be reproduced, transcribed, stored in an electronic retrieval system, translated into any language or computer language, or be transmitted in any form whatsoever, without the prior written consent of the publisher.
Authorized European Representative:MIS Germany, Paulinenstraße 12a, 32427 Minden, GERMANY
0483
© MIS Corporation. All Rights Reserved.
MIS Implants Technologies Ltdwww.mis-implants.com
MC
-UN
O08 R
ev.1M
C-U
NO
08 Rev.1
© MIS Corporation. All rights reserved.
MIS’ Quality System complies with international
quality standards: ISO 13485:2003 - Quality
Management System for Medical Devices, ISO
9001: 2008 - Quality Management System and
CE Directive for Medical Devices 93/42/EEC. MIS’
products are cleared for marketing in the USA
and CE approved.MIS Implants Technologies Ltd.www.mis-implants.com
®
MC
-CO
NE
N R
ev.8