Upload
hoangngoc
View
216
Download
0
Embed Size (px)
Citation preview
American Standard Ductless Systems Product Catalog
A Comfortable, Convenient Solution
Built To A Higher Standard.
2
Contents
Table of ContentsAmerican Standard Ductless Systems.
Reliable Comfort, Precise Control.
Three levels of filtration keep air clean and healthy.
American Standard’s commitment to quality includes making sure the air you breathe is as free as possible of dust and other contaminants. That’s why each indoor unit provides triple filtration. First, a standard filter traps dusts and other particulates; second, an active carbon filter absorbs both physical debris and chemical pollutants. Finally, a catechin additive filter provides anti-oxidation and sterilization to inhibit the development of bacteria. So you not only stay comfortable, you breathe easy.
Polluted Air Clean Air
Catechin FilterActive Carbon Filter
Unique properties of the Catechin filter
The catechin additive is abstracted from natural green tea, providing a long-lasting sterilization of dust and removing up to 95% of potentially harmful bacteria.
Energy Efficiency
American Standard Heating & Air Conditioning ductless systems use variable-speed inverter technology. This allows the compressor to continually modulate and adjust to the most efficient speed to meet your demands.
The variable-speed inverter technology used in American Standard ductless systems is up to 35% more efficient than a conventional single-speed compressor.
Higher EER/COP levels allow you to reach the desired temperature quickly without sacrificing your electricity bills.
Inverter Type
Set
Tem
per
atur
e
Small TemperatureDifference
Cools RoomIn Less Time
Comfortable
Not Cool Enough
Too Cool
Non-Inverter Type
How variable-speed inverter technology works.
Designed and built with the commitment to high-quality craftsmanship you expect from American Standard, our ductless systems are easy to install, offer flexibility in design and provide efficiency and economy with two simple components, an outdoor compressor/condenser and one or more indoor units.
American Standard ductless systems are an ideal choice as a retrofit for houses without ducted heating systems, for room additions where installing ductwork is impractical or too expensive, or where the main system lacks capacity to expand, as well as for areas of the home that require additional heating or cooling.
American Standard ductless mini-splits avoid the energy loss associated with ductwork and save money because they are separate from the central system and operate only when needed.
American Standard ductless systems deliver the reliability you expect. And they also come with innovative features that ensure precision control for maximum efficiency, economy, and comfort.
Robust GrillNew strong hot dip galvanized steel grill prevents damage and has no negative impact on airflow.
Intelligent DefrostAuto defrosting improves the system’s heating efficiency and helps you save power.
Blue FinSpecial anti-corrosion coil treatment increases durability and ensures continued efficiency (standard on all heat pump models).
Twin Rotary DC CompressorThe brushless compressor provides better balance, lower power consumption and higher efficiency.
Compressor ProtectionCompressor stops or delays operation if conflicts arise.
Quick Reference ................................ 4Model Nomenclature ........................ 7Air Conditioner 16+ SEER ................ 8Heat Pump 16+ SEER ....................... 9Heat Pump 18-22+ SEER ................ 10
Mini-Sp
lits
Multi-Sp
lits Quick Reference ................................ 5
Sizing Combinations ......................... 6Model Nomenclature ........................ 7Heat Pump Outdoor ....................... 12Heat Pump Indoor .......................... 14
3
Multi-Split Systems
Ductless systems flex to meet your specific needs.
Customizing your system by combining the different types of indoor units to meet the needs of each room means your ductless system can provide exactly the comfort you require, based on the size of the space and the amount of insulation. Indoor units can be added later to unused ports as your system expands with your needs. And since each unit only operates when needed, your multi-split system can save energy and cut cost while keeping you comfortable.
• One outdoor multi-split unit from American Standard can support up to five indoor units with separate temperature zones.
• Indoor units can be wall or ceiling mounted. When paired with an outdoor multi-split system, these units provide the benefits of a zoning system without the costly addition of zoning hardware or ductwork. The system adjusts to your needs, providing consistent comfort with the convenience of flexibility.
• Floor/ceiling units provide flexible installation options to accommodate room requirements without requiring ductwork or zoning hardware. The specially designed air vent ensures quiet comfort during operation. The removable, washable filter ensures easy maintenance.
• The compact design and quiet operation of the indoor console unit make it suitable for any room in the home. A removable, washable filter ensures easy maintenance for a consistent flow of fresh, healthy air.
American Standard Ductless Controllers provide reliable comfort and convenience.
Most American Standard Ductless indoor units may be controlled by either a wired or wireless controller, so you can easily adjust your system, even when indoor units are ceiling or wall mounted.
• See a clear display of temperature, operational mode, and time settings.
• Set or adjust times of operation, temperature and more.
• Set directional louvers on the unit to distribute air in a fixed direction or to swing between any desired angles.
Wireless controller(sold separately)
Wired controller included with Floor/Ceiling, Cassette, and Concealed units.
Controllers
4
Mini-Split
Air ConditionerIndoor High
Wall Mounted16+ SEER
9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
4MYW6509A10N0BA4TYK6509A10N0BA
4MYW6512A10N0BA4TYK6512A10N0BA
4MYW6518A10N0BA4TYK6518A10N0BA
4MYW6524A10N0BA 4TYK6524A10N0BA
Heat PumpIndoor High
Wall Mounted16+ SEER
9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
4MXW6509A10N0BA4TXK6509A10N0BA
4MXW6512A10N0BA 4TXK6512A10N0BA
4MXW6518A10N0BA4TXK6518A10N0BA
4MXW6524A10N0BA4TXK6524A10N0BA
Heat PumpIndoor High
Wall Mounted 18-22 SEER
9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH 36,000 BTUH
4MXW8509A10N0BA4TXK8509A10N0BA
4MXW8512A10N0BA4TXK8512A10N0BA
4MXW8518A10N0BA4TXK8518A10N0BA
4MXW8524A10N0BA4TXK8524A10N0BA
4MXW8536A10N0BA4TXK8536A10N0BA
Quiet DesignSpecially designed air vent efficiently reduces operation noise, as low as 26 dB.
Turbo FunctionHigh speed operation quickly reaches desired temperature.
Sleep Mode FunctionTemperature rises/falls automatically to maintain room comfort and save energy while you sleep.
Anti-cold DesignTo prevent blowing cold air directly to the room, air is pre-heated during heating operation.
TimerOperate the unit automatically only when you want by setting the timer.
Energy EfficiencyQuickly reach the desired temperature without sacrificing your electricity bills with our higher EER/COP levels.
Robust GrillPrevent damage without impacting airflow with our strong, hot-dip galvanized steel grill.
Intelligent DefrostAuto defrosting is implemented if necessary. It improves the system’s heating efficiency and helps you save power. (Standard on all heat pump models.)
Blue FinIncrease durability and ensure continued efficiency with our special anti-corrosion coil treatment. (Standard on all heat pump models.)
Twin Rotary DC CompressorProvides better balance and higher efficiency.
Compressor ProtectionCompressor stops or delays operation if conflicts arise.
Take Comfort In Our WarrantiesThe American Standard Ductless System Registered Limited Warranty terms* include: 5 years on all functional parts.
* Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at AmericanStandard.com or by phone at 800-554-6413, otherwise American Standard Heating & Air Conditioning’s Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on AmericanStandard.com. Ask your dealer for full warranty information at time of purchase. Warranties are for residential and multi-family use only, some exclusions may apply.
Consumer brochures available on ASDealerNet™:
Consumer Brochure, 10-1185-04
Mini-Split Quick Reference
For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.
5
Mini-Split Quick Reference
Multi-Split Heat Pumps - Outdoor18,000 BTUH 24,000 BTUH 30,000 BTUH 36,000 BTUH 42,000 BTUH
4TXM6518A1020BA 4TXM6524A1030BA 4TXM6530A1040BA 4TXM6536A1040BA 4TXM6542A1050BA
Energy EfficiencyQuickly reach the desired temperature without sacrificing your electricity bills with our higher EER/COP levels.
Robust GrillPrevent damage without impacting airflow with our strong, hot-dip galvanized steel grill.
Intelligent DefrostAuto defrosting is implemented if necessary. It improves the system’s heating efficiency and helps you save power. (Standard on all heat pump models.)
Compressor ProtectionCompressor stops or delays operation if conflicts arise.
Twin Rotary DC CompressorProvides better balance and higher efficiency.
Blue FinIncrease durability and ensure continued efficiency with our special anti-corrosion coil treatment. (Standard on all heat pump models.)
Multi-Split Heat Pumps - Indoor Options
High Wall Mounted
9000 BTUH 12000 BTUH 18000 BTUH 21000 BTUH 24000 BTUH
4MXW8509A10N0BA 4MXW8512A10N0BA 4MXW8518A10N0BA
Not Available Not Available
Concealed
4MXD8509A10N0AA 4MXD8512A10N0AA 4MXD8518A10N0AA 4MXD8521A10N0AA 4MXD8524A10N0AA
Cassette Not Available
4MXC8512A10N0AA 4MXC8518A10N0AA
Not Available
4MXC8524A10N0AA
Console
4MXF8509A10N0AA 4MXF8512A10N0AA 4MXF8518A10N0AA
Not Available Not Available
Floor Ceiling
4MXX8509A10N0AA 4MXX8512A10N0AA 4MXX8518A10N0AA
Not Available
4MXX8524A10N0AA
All Indoor Units
Quiet DesignSpecially designed air vent efficiently reduces operation noise, as low as 26 dB.
Compact DesignThe compact construction and simple structure make the console and floor/ceiling models easy to install and maintain.
Turbo FunctionHigh speed operation quickly reaches desired temperature.
Sleep Mode FunctionTemperature rises/falls automatically to maintain room comfort and save energy while you sleep.
Auto Clean and Triple FiltrationFan runs when unit is stopped to reduce moisture and inhibit the development of bacteria, and the triple filtration system further cleans the air that you breathe.
Anti-cold DesignTo prevent blowing cold air directly to the room, air is pre-heated during heating operation.
TimerTimer allows the unit to run only during specific time intervals.
Take Comfort In Our WarrantiesThe American Standard Ductless System Registered Limited Warranty terms* include: 5 years on all functional parts.
Concealed and Cassette Indoor Units
Built-in Drain PumpEasily drain condensation from either unit with the built-in drain pump.
Washable FilterTo reduce moisture on filter and provide fresh, healthy air into the room, clean filter regularly with water.
Floor/Ceiling and Console Indoor Units
Anti-Cold Feature Air is pre-heated during heating operation to prevent blowing cold air directly to the room.
Washable FilterTo reduce moisture on filter and provide fresh, healthy air into the room, clean filter regularly with water.
Multi-Split Quick Reference
6
4 combinations (18,000 BTU)
4TXM6518A1020BA
One Unit Two Units
9
12
9+9
9+12
11 combinations (24,000 BTU)
4TXM6524A1030BA
Two Units Three Units
9+9
9+18
12+18
9+12
12+12
18+18
9+9+9
9+9+12
12+12+12
9+12+12
9+9+18
16 combinations (30,000 BTU)
4TXM6530A1040BA
Two Units Three Units Four Units
9+9
9+18
12+18
9+12
12+12
18+18
9+9+9
9+12+12
12+12+18
9+9+12
9+12+18
9+9+18
12+12+12
9+9+9+9 9+9+9+12 9+9+12+12
47 combinations (36,000 BTU)
4TXM6536A1040BA
Two Units Three Units Four Units
9+9
9+12
9+18
9+21
9+24
12+12
12+18
12+21
12+24
18+18
18+21
18+24
21+21
21+24
24+24
9+9+9
9+9+12
9+9+18
9+9+21
9+9+24
9+12+12
9+12+18
9+12+21
9+12+24
9+18+18
9+18+21
9+18+24
9+21+21
12+12+12
12+12+18
12+12+21
12+12+24
12+18+18
12+18+21
18+18+18
9+9+9+9
9+9+9+12
9+9+9+18
9+9+9+21
9+9+9+24
9+9+12+12
9+9+12+18
9+9+12+21
9+9+18+18
9+12+12+12
9+12+12+18
12+12+12+12
87 combinations (42,000 BTU)
4TXM6542A1050BA
Two Units Three Units Four Units Five Units
9+9
9+12
9+18
9+21
9+24
12+12
12+18
12+21
12+24
18+18
18+21
18+24
21+21
21+24
24+24
9+9+9
9+9+12
9+9+18
9+9+21
9+9+24
9+12+12
9+12+18
9+12+21
9+12+24
9+18+18
9+18+21
9+18+24
9+21+21
9+21+24
9+24+24
12+12+12
12+12+18
12+12+21
12+12+24
12+18+18
12+18+21
12+18+24
12+21+21
12+21+24
12+24+24
18+18+18
18+18+21
18+18+24
18+21+21
21+21+21
9+9+9+9
9+9+9+12
9+9+9+18
9+9+9+21
9+9+9+24
9+9+12+12
9+9+12+18
9+9+12+21
9+9+12+24
9+9+18+18
9+9+18+21
9+9+18+24
9+9+21+21
9+12+12+12
9+12+12+18
9+12+12+21
9+12+12+24
9+12+18+18
9+12+18+21
9+12+21+21
9+18+18+18
12+12+12+12
12+12+12+18
12+12+12+21
12+12+12+24
12+12+18+18
12+12+18+21
9+9+9+9+9
9+9+9+9+12
9+9+9+9+18
9+9+9+9+21
9+9+9+9+24
9+9+9+12+12
9+9+9+12+18
9+9+9+12+21
9+9+9+18+18
9+9+12+12+12
9+9+12+12+18
9+9+12+12+21
9+12+12+12+12
9+12+12+12+18
12+12+12+12+12
Multi-Split Sizing Combinations
7
Refrigerant Service Digit4 = R-410A A = First Sequence
Brand Minor Design SequenceT = Mini-Split Outdoor Unit A = First Design Sequence
B = Second Design SequenceFunctional Type
X = Heat Pump Inverter Reserved for Future UseY = Cooling Only Inverter 0 = Not Currently Used
Configuration Outdoor Unit Regional Markets Served (1:1 Systems)
K = Single Refrigerant Circuit N = North America MarketM = Multiple Refrigerant Circuits or Number of Refrigerant Ports
(Multi-Split Systems)Efficiency Tier 2 = Two Port System
6 = 16+ SEER 3 = Three Port System8 = 18+ SEER 4 = Four Port System
5 = Five Port SystemConnection Type
5 = Flare Reserved for Future Use 0 = Not Currently Used
Nominal Capacity (Btu/h x 1,000)09 = 9,000 btu/h Electric Power Supply Characteristics12 = 12,000 btu/h 1 = 208-230/60/1 18 = 18,000 btu/h24 = 24,000 btu/h Major Develompent Sequence 30 = 30,000 btu/h A = First Development Sequence36 = 36,000 btu/h B = Second Development Sequence 42 = 42,000 btu/h C = Third Development Sequence
12N
130
14B5
9A
10 111 0
OUTDOOR UNIT MODEL NOMENCLATURE
A157-8
1214
2T
3X
4K
56
6
12
Refrigerant Service Digit4 = R-410A A = First Sequence
Brand Minor Design SequenceM = Mini-Split Indoor Unit A = First Design Sequence
B = Second Design SequenceFunctional Type
X = Heat Pump Inverter Reserved for Future UseY = Cooling Only Inverter 0 = Not Currently Used
Configuration Indoor Unit Regional Markets Served (1:1 Systems)
W = High Wall Unit N = North America MarketD = Concealed (Duct) Unit C = Cassette Unit Reserved for Future UseF = Floor Console Unit 0 = Not Currently UsedX = Convertible (Floor/Ceiling) Mount
Electric Power Supply CharacteristicsEfficiency Tier 1 = 208-230/60/1
6 = 16+ SEER8 = 18+ SEER Major Develompent Sequence A = First Development Sequence
Connection Type B = Second Development Sequence 5 = Flare
Nominal Capacity (Btu/h x 1,000)09 = 9,000 Btu/h12 = 12,000 Btu/h18 = 18,000 Btu/h 24 = 24,000 btu/h30 = 30,000 btu/h36 = 36,000 btu/h
INDOOR UNIT MODEL NOMENCLATURE
6 B9 10 11 13 14A 1 0 N 0
14
2M
3 65 A
157-812X
4K
5
Model Nomenclatures
Outdoor Units
Refrigerant Service Digit4 = R-410A A = First Sequence
Brand Minor Design SequenceT = Mini-Split Outdoor Unit A = First Design Sequence
B = Second Design SequenceFunctional Type
X = Heat Pump Inverter Reserved for Future UseY = Cooling Only Inverter 0 = Not Currently Used
Configuration Outdoor Unit Regional Markets Served (1:1 Systems)
K = Single Refrigerant Circuit N = North America MarketM = Multiple Refrigerant Circuits or Number of Refrigerant Ports
(Multi-Split Systems)Efficiency Tier 2 = Two Port System
6 = 16+ SEER 3 = Three Port System8 = 18+ SEER 4 = Four Port System
5 = Five Port SystemConnection Type
5 = Flare Reserved for Future Use 0 = Not Currently Used
Nominal Capacity (Btu/h x 1,000)09 = 9,000 btu/h Electric Power Supply Characteristics12 = 12,000 btu/h 1 = 208-230/60/1 18 = 18,000 btu/h24 = 24,000 btu/h Major Develompent Sequence 30 = 30,000 btu/h A = First Development Sequence36 = 36,000 btu/h B = Second Development Sequence 42 = 42,000 btu/h C = Third Development Sequence
12N
130
14B5
9A
10 111 0
OUTDOOR UNIT MODEL NOMENCLATURE
A157-8
1214
2T
3X
4K
56
6
12
Refrigerant Service Digit4 = R-410A A = First Sequence
Brand Minor Design SequenceM = Mini-Split Indoor Unit A = First Design Sequence
B = Second Design SequenceFunctional Type
X = Heat Pump Inverter Reserved for Future UseY = Cooling Only Inverter 0 = Not Currently Used
Configuration Indoor Unit Regional Markets Served (1:1 Systems)
W = High Wall Unit N = North America MarketD = Concealed (Duct) Unit C = Cassette Unit Reserved for Future UseF = Floor Console Unit 0 = Not Currently UsedX = Convertible (Floor/Ceiling) Mount
Electric Power Supply CharacteristicsEfficiency Tier 1 = 208-230/60/1
6 = 16+ SEER8 = 18+ SEER Major Develompent Sequence A = First Development Sequence
Connection Type B = Second Development Sequence 5 = Flare
Nominal Capacity (Btu/h x 1,000)09 = 9,000 Btu/h12 = 12,000 Btu/h18 = 18,000 Btu/h 24 = 24,000 btu/h30 = 30,000 btu/h36 = 36,000 btu/h
INDOOR UNIT MODEL NOMENCLATURE
6 B9 10 11 13 14A 1 0 N 0
14
2M
3 65 A
157-812X
4K
5
Indoor Units
8
Rated Cooling Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
Cooling Capacity (@95F) (Btu/h) (Min/Max) 3,800 / 11,500 3,300 / 12,500 4,500 / 21,000 6400 / 24,000
Total Capacity (W) (High/Standard/Low): 3370 / 2637 / 1114 3663 / 3516 / 967 6155 / 5276 / 1319 7032 / 6446 / 1875
SEER 16.0 16.0 16.0 16.0
EER (@95F) 10.23 9.8 11.1 10.0
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Rated Power Input (W) 882 1224 1621 2200
Nominal Input Current (A) 4.01 5.56 7.37 10
Indoor Model Number 4MYW6509A10N0BA 4MYW6512A10N0BA 4MYW6518A10N0BA 4MYW6524A10N0BA
Dehumidifying Volume (pt./h) 3.1 5.4 7.0 8.2
Fan Motor Speed (r/min) (SH/H/M/L) 1300 / 1100 / 900 / 700 1350 / 1150 / 950 / 750 1400 / 1150 / 1000 / 850 1450 / 1180 / 1000 / 850
Sound PRESSURE Level dB (A)(SH/H/M/L) 43 / 38 / 32 / 26 44 / 39 / 33 / 28 48 / 43 / 38 / 34 49 / 43 / 39 / 34
Fuse (A) 3.15 3.15 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4 1/4
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2 1/2
Uncrated Dimension (W/D/H) (inch) 30.3 x 7.9 x 11.1 30.3 x 7.9 x 11.1 34.1 x 8.5 x 12.0 39.7 x 8.7 x 12.4
Net Weight /Gross Weight (lbs) 18.7 / 25.4 19.8 / 26.5 26.4 / 35.2 33.0 / 44.0
Outdoor Model Number - Cooling Only 4TYK6509A10N0B 4TYK6512A10N0BA 4MYW6518A10N0BA 4MYW6524A10N0BA
Sound PRESSURE Level dB (A) 49 52 56 56
MCA 10.0 10.0 15.0 16.0
MOP 15.0 15.0 25.0 25.0
Working Temp Range (°F) -0 ~ 110 -0 ~ 110 -0 ~ 110 -0 ~ 110
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4 1/4
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2 1/2
Condensate Drain Pipe Size 5/8 5/8 5/8 5/8
Max Height Distance (ft) 65 65 65 65
Max Length Distance (ft) 100 100 130 130
Uncrated Dimension (W/L/H) (inch) 28.0 x 12.5 x 21.7 28.0 x 12.5 x 21.7 37.6 x 15.6 x 27.8 37.6 x 15.6 x 27.8
Net Weight /Gross Weight (lbs) 63.9 / 72.7 68.3 / 77.1 105 / 117 114.5 / 125.5
Wireless Controller Required (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1
See the Service First Mini-Split Accessory Catalog for the complete accessory list
Wireless controller required. (sold separately)
Mini-Split System Air Conditioner (16 SEER)
Space to the ceiling
Space to the wall
Space to the wall
Air outlet side min
5.9 in. min 5.9 in. min
min 5.9 in.
118.1 in.
valve cover
Space to the wal l
11.8in. min
19.7 in. min
19.7
in. m
in
11.8 in. min
Air outlet side
Space to the wall
Air inlet side
78.7 in. min
• Cooling efficiency range: 16 SEER
• Heating efficiency range 8~9.5 HSPF
• Nominal capacity range: 9~24 MBH
• Power Supply: 208-230/60/1
• All systems are available as cooling or heat pump
• All combinations are AHRI approved
• Low sound level (as low as 26dB)
• Refrigerant: R-410A
Min
i-S
plit
s
9
Mini-Split Heat Pumps (16 SEER)
Rated Cooling Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 18,000 BTUH 22,000 BTUH
Rated Heating Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 19,200 BTUH 24,200 BTUHCooling Capacity (@95F) (Btu/h) (Min/Max)
3,800 / 11,500 3,300 / 12,500 4,500 / 21,000 6400 / 24,000
Heating Capacity (@47F) (Btu/h) (Min/Max)
3,300 / 11,500 3,400 / 12,500 4,000 / 23,000 4,100 / 26,600
Heating Capacity (@17F) (Btu/h) (Max) 5,300 6,800 12,000 18,600
Heating Capacity (@5F) (Btu/h) (Min) 6,500 7,800 12,900 14,100Total Cooling Capacity (W) (High/Standard/Low):
3370 / 2637 / 1114 3663 / 3516 / 967 6155 / 5276 / 1319 7032 / 6446 / 1875
Total Heating Capacity (W) (High/Standard/Low):
3370 / 2637 / 967 3663 / 3516 / 996 6741 / 5276 / 1172 7796 / 6446 / 1202
SEER 16.0 16.0 16.0 16.0
HSPF 8.5 8.5 8.0 8.5
Cooling EER (@95F) 10.24 9.8 11.1 10.0
Heating EER (@95F) 11.69 11.43 8.0 8.64
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Cooling Rated Power Input (W) 882 1224 1,621 2,200
Heating Rated Power Input (W) 770 1050 2,400 2,800
Cooling Nominal Input Current (A) 4.01 5.56 7.37 10.00
Heating Nominal Input Current (A) 4.20 4.66 10.91 14.17
Indoor Model Number 4MXW6509A10N0BA 4MXW6512A10N0BA 4MXW6518A10N0BA 4MXW6524A10N0BA
Dehumidifying Volume (pt./h) 3.0 5.4 7.0 8.2Cooling Fan Motor Speed (r/min) (SH/H/M/L)
1300 / 1100 / 900 / 700 1350 / 1150 / 950 / 750 1400 / 1150 / 1000 / 850 1350 / 1150 / 1000 / 850
Heating Fan Motor Speed (r/min) (SH/H/M/L)
1300 / 1150 / 980 / 820 1350 / 1190 / 1020 / 850 1450 / 1250 / 1100 /950 1350 / 1150 / 1000 / 900
Sound PRESSURE Level dB (A)(SH/H/M/L)
43 / 38 / 32 / 26 44 / 39 / 33 / 28 48 / 43 / 38 / 34 49 / 43 / 39 / 34
Fuse (A) 3.15 3.15 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4 1/4
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2 1/2
Uncrated Dimension (W/D/H) (inch) 30.3 x 7.9 x 11.1 30.3 x 7.9 x 11.1 34.1 x 8.5 x 12.0 39.7 x 8.7 x 12.4
Net Weight /Gross Weight (lbs) 18.7 / 25.4 19.8 / 26.5 26.4 / 35.2 33.0 / 44.0
Outdoor Model Number 4TXK6509A10N0BA 4TXK6512A10N0BA 4TXK6518A10N0BA 4TXK6524A10N0BA
Sound PRESSURE Level dB (A) 49 52 56 46
Cooling Working Temp Range (°F) -0 ~ 110 -0 ~ 110 -0 ~ 110 -0 ~ 110
Heating Working Temp Range (°F) 5 ~ 75 5 ~ 75 5 ~ 75 5 ~ 75
MCA 10.0 10.0 -0 ~ 110 16.0
MOP 15.0 15.0 5 ~ 75 25.0
Outer Diameter Liquid Pipe (inch) 1/4 1/4 -0 ~ 110 1/4
Outer Diameter Gas Pipe (inch 3/8 3/8 5 ~ 75 1/2
Condensate Drain Pipe Size 5/8 5/8 5/8 5/8
Max Height Distance (ft) 65 65 65 65
Max Length Distance (ft) 100 100 130 130
Uncrated Dimension (W/L/H) (inch) 28.0 x 12.5 x 21.7 28.0 x 12.5 x 21.7 37.6 x 15.6 x 27.6 37.6 x 15.6 x 27.6
Net Weight /Gross Weight (lbs) 63.9 / 72.7 68.3 / 77.1 105 / 117 114.5 / 125.5Wireless Controller Required (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1
Wireless controller required. (sold separately)
See the Service First Mini-Split Accessory Catalog for the complete accessory list
• Cooling efficiency range: 16 SEER
• Heating efficiency range 8~9.5 HSPF
• Nominal capacity range: 9~24 MBH
• Power Supply: 208-230/60/1
• All systems are available as cooling or heat pump
• All combinations are AHRI approved
• Low sound level (as low as 26dB)
• Refrigerant: R-410A
Min
i-Sp
lits
10
Rated Cooling Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 18,000 BTUH
Rated Heating Capacity (Btu/h) 9,800 BTUH 13,000 BTUH 19,800 BTUH
Cooling Capacity (@95F) (Btu/h) (Min/Max) 3,500 / 9,600 3,100 / 13,000 5,970 / 22,350
Heating Capacity (@47F) (Btu/h) (Min/Max) 2,200 / 11,000 2,400 / 14,000 5,970 / 22,350
Heating Capacity (@17F) (Btu/h) (Max) 5,500 7,600 12,700
Heating Capacity (@5F) (Btu/h) (Min) 7,400 8,500 13,600
Total Cooling Capacity (W) (High/Standard/Low): 2813 / 2637 / 1025 3810 / 3517 / 909 6550 / 5275 / 1750
Total Heating Capacity (W) (High/Standard/Low): 3224 / 2637 / 645 4103 / 3810 / 703 6550 / 5275 / 1750
SEER 22.0 20.0 18.0
HSPF 9.2 9.2 10.0
Cooling EER (@95F) 14.5 12.0 12
Heating EER (@95F) 13.07 10.83 9.28
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Cooling Rated Power Input (W) 620 1000 1500
Heating Rated Power Input (W) 750 1200 2133
Cooling Nominal Input Current (A) 2.80 4.55 6.82
Heating Nominal Input Current (A) 3.04 5.20 9.7
Indoor Model Number 4MXW8509A10N0BA 4MXW8512A10N0BA 4MXW8518A10N0BA
Dehumidifying Volume (pt./h) 4.6 5.4 7.0
Cooling Fan Motor Speed (r/min) (SH/H/M/L) 1260 / 1100 / 950 / 750 1330 / 1100 / 950 / 750 1500 / 1200 / 1050 / 900
Heating Fan Motor Speed (r/min) (SH/H/M/L) 1320 / 1180 / 1050 / 950 1350 / 1200 / 1080 / 950 1500 / 1250 / 1150 / 1050
Sound PRESSURE Level dB (A)(SH/H/M/L) 42 / 38 / 35 / 32 44 / 39 / 36 / 33 49 / 44 / 40 / 35
Fuse (A) 3.15 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2
Uncrated Dimension (W/D/H) (inch) 33.3 x 7.1 x 10.8 33.3 x 7.1 x 10.8 37.0 x 7.9 x 11.7
Net Weight /Gross Weight (lbs) 22.0 / 28.6 22.0 / 28.6 28.6 x 37.4
Outdoor Model Number 4TXK8509A10N0BA 4TXK8512A10N0BA 4TXK8518A10N0BA
Sound PRESSURE Level dB (A) 50 52 55
Cooling Working Temp Range (°F) -0 ~ 110 -0 ~ 110 -0 ~ 110
Heating Working Temp Range (°F) 5 ~ 75 5 ~ 75 5 ~ 75
MCA 10.0 10.0 16.0
MOP 15.0 15.0 20.0
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2
Condensate Drain Pipe Size 5/8 5/8 5/8
Max Height Distance (ft) 65 65 65
Max Length Distance (ft) 100 100 130
Uncrated Dimension (W/L/H) (inch) 33.4 x 12.6 x 21.3 33.4 x 12.6 x 21.3 37.6 x 15.6 x 27.6
Net Weight /Gross Weight (lbs) 79.3 / 90.3 88.1 / 96.9 99.1 / 110.1
Wireless Controller Required (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1
Mini-Split Heat Pumps (18-22 SEER)
See the Service First Mini-Split Accessory Catalog for the complete accessory list
Wireless controller required. (sold separately)
• Cooling efficiency range: 18~22 SEER
• Nominal capacity range: 9~36 MBH
• Heating efficiency range 8.2~10 HSPF
• Power Supply: 208-230/60/1
• Available as heat pump systems only
• All models will qualify as Energy Star (except 3 ton)
• All combinations are AHRI approved
• Low Sound Level (as low as 26dB)
• Refrigerant: R-410A
Min
i-S
plit
s
11
Rated Cooling Capacity (Btu/h) 21,400 BTUH 33,600 BTUH
Rated Heating Capacity (Btu/h) 23,000 BTUH 34,600 BTUH
Cooling Capacity (@95F) (Btu/h) (Min/Max) 9,600 / 25,000 7,400 / 36,000
Heating Capacity (@47F) (Btu/h) (Min/Max) 9,600 / 25,000 15,000 / 36,000
Heating Capacity (@17F) (Btu/h) (Max) 15,000 20,600
Heating Capacity (@5F) (Btu/h) (Min) 14,400 17,600
Total Cooling Capacity (W) (High/Standard/Low): 7325 / 6270 / 2812 10550 / 9850 / 2170
Total Heating Capacity (W) (High/Standard/Low): 7325 / 6270 / 2812 10550 / 10140 / 4390
SEER 18.0 16.0
HSPF 10.0 8.2
Cooling EER (@95F) 12.0 9.2
Heating EER (@95F) 9.38 9.7
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1
Cooling Rated Power Input (W) 1783 3650
Heating Rated Power Input (W) 2451 3567
Cooling Nominal Input Current (A) 8.1 16.59
Heating Nominal Input Current (A) 11.14 16.21
Indoor Model Number 4MXW8524A10N0BA 4MXW8536A10N0BA
Dehumidifying Volume (pt./h) 9.6 13.1
Cooling Fan Motor Speed (r/min) (SH/H/M/L) 1500 / 1200 / 1050 / 900 1550 / 1400 / 1300
Heating Fan Motor Speed (r/min) (SH/H/M/L) 1500 / 1350 / 1220 / 1050 1550 / 1400 / 1300
Sound PRESSURE Level dB (A)(SH/H/M/L) 53 / 45 / 41 / 37 59 / 56 / 53
Fuse (A) 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4
Outer Diameter Gas Pipe (inch) 5/8 5/8
Uncrated Dimension (W/D/H) (inch) 39.6 x 8.6 x 12.4 53.1 x 10.0 x 12.8
Net Weight /Gross Weight (lbs) 35.2 x 46.2 44.1 / 59.5
Outdoor Model Number 4TXK8524A10N0BA 4TXK8536A10N0BA
Sound PRESSURE Level dB (A) 58 65
Cooling Working Temp Range (°F) -0 ~ 110 -0 ~ 110
Heating Working Temp Range (°F) 5 ~ 75 5 ~ 75
MCA 16.0 23.0
MOP 20.0 35.0
Outer Diameter Liquid Pipe (inch) 1/4 1/4
Outer Diameter Gas Pipe (inch) 5/8 5/8
Condensate Drain Pipe Size 5/8 5/8
Max Height Distance (ft) 65 65
Max Length Distance (ft) 130 130
Uncrated Dimension (W/L/H) (inch) 38.6 x 16.8 x 31.1 38.6 x 16.8 x 31.1
Net Weight /Gross Weight (lbs) 132.1 / 145.3 161 / 170
Wireless Controller Required (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1
Wireless controller required. (sold separately)
See the Service First Mini-Split Accessory Catalog for the complete accessory list
Mini-Split Heat Pumps (18-22 SEER)
• Cooling efficiency range: 18~22 SEER
• Nominal capacity range: 9~36 MBH
• Heating efficiency range 8.2~10 HSPF
• Power Supply: 208-230/60/1
• Available as heat pump systems only
• All models will qualify as Energy Star (except 3 ton)
• All combinations are AHRI approved
• Low Sound Level (as low as 26dB)
• Refrigerant: R-410A
Min
i-Sp
lits
12
Rated Capacity (Btu/h) 18,000 BTUH 24,000 BTUH
Outdoor Model Number 4TXM6518A1020BA 4TXM6524A1030BA
Cooling Capacity Range (Btu/h) 7,000 - 21,000 7,500 - 33,000
Rated Heating Capacity 19,000 29,000
Heating Capacity Range (@47F) (Btu/h) 8,530 - 22,600 7,500 - 35,000
Heating Capacity (@17F) (Btu/h) (Max) 9,600 15,000
Heating Capacity (@5F) (Btu/h) (Max) 8,600 12,100
SEER / HSPF 16.0 / 8.2 16.0 / 8.2
EER 10.2 8.2
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1
Compressor Power Input (W) 1,245 2,200
Compressor RLA (A) 9.56 14.69
Fan Motor Speed (r/min) 830 / 670 / 500 690 / 600 / 500
Sound PRESSURE Level dB (A)(SH/H/M/L) 56 59
Fuse (A) 20 30
Outer Diameter Liquid Pipe (inch) 1/4, 1/4 1/4, 1/4, 1/4
Outer Diameter Gas Pipe (inch) 3/8, 3/8 3/8, 3/8, 3/8
Max Height Distance (ft) 16 33
Max Length Distance (ft) - Single Unit Each 33 66
Max Length Distance (ft) - Multiple Units Total 66 230
Uncrated Dimension (W/L/H) (inch) 35.4 x 14.9 x 23.5 37.6 x 15.6 x 27.6
Net Weight /Gross Weight (lbs) 94.8 / 105.8 134.5 / 145.5
Working Temp Range (°F) -0 ~ 110 / 5 ~ 75 -0 ~ 110 / 5 ~ 75
MCA 15.0 20.0
MOP 20.0 30.0
Condensate Drain Pipe Size 5/8 5/8
Multi-Split Heat Pumps: Outdoor (16 SEER)
See the Service First Mini-Split Accessory Catalog for the complete accessory list
• Flexibility to accommodate to different applications
• Connect up to 5 indoor units to a single condensing unit
• Capacity range: 18 ~ 42 MBH
• Efficiency level: 16 SEER
• Refrigerant: R-410A
• Heat pump systems
Mu
lti-
Sp
lits
13
Rated Capacity (Btu/h) 30,000 BTUH 36,000 BTUH 42,000 BTUH
Outdoor Model Number 4TXM6530A1040BA 4TXM6536A1040BA 4TXM6542A1050BA
Cooling Capacity Range (Btu/h) 7,500 - 34,000 8,530 - 34,120 8,530 - 46,403
Rated Heating Capacity 30,400 37,200 44,500
Heating Capacity Range (@47F) (Btu/h) 7,500 - 36,000 10,660 - 40,900 10,660 - 47,760
Heating Capacity (@17F) (Btu/h) (Max) 16,500 22,000 24,800
Heating Capacity (@5F) (Btu/h) (Max) 13,300 14,400 17,600
SEER / HSPF 16.0 / 8.2 16.0 / 8.2 16.0 / 8.0
EER 7.3 7.95 9
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Compressor Power Input (W) 2,200 2,200 3,010
Compressor RLA (A) 19.62 19.62 19.07
Outdoor Model Number 4TXM6530A1040BA 4TXM6536A1040BA 4TXM6542A1050BA
Fan Motor Speed (r/min) 690 / 600 / 500 820 / 640 / 560 860 / 650 / 550
Sound PRESSURE Level dB (A)(SH/H/M/L) 59 59 58
Fuse (A) 45 45 40
Outer Diameter Liquid Pipe (inch) 1/4, 1/4, 1/4, 1/4 1/4, 1/4, 1/4, 3/8 1/4, 1/4, 1/4, 3/8
Outer Diameter Gas Pipe (inch) 3/8, 3/8, 3/8, 3/8 3/8, 3/8, 1/2, 5/8 3/8, 3/8, 1/2, 1/2, 5/8
Max Height Distance (ft) 33 33 33
Max Length Distance (ft) - Single Unit Each 66 66 82
Max Length Distance (ft) - Multiple Units Total 230 230 230
Uncrated Dimension (W/L/H) (inch) 37.6 x 15.6 x 27.6 36.2 x 16.8 x 31.1 40.0 x 17.3 x 43.4
Net Weight /Gross Weight (lbs) 136.7 / 147.7 152.6 / 164.9 224.4 / 246.4
Working Temp Range (°F) -0 ~ 110 / 5 ~ 75 -0 ~ 110 / 5 ~ 75 -0 ~ 110 / 5 ~ 75
MCA 26.0 28.0 26.0
MOP 45.0 45.0 40.0
Condensate Drain Pipe Size 5/8 5/8 5/8
Multi-Split Heat Pumps: Outdoor (16 SEER)
See the Service First Mini-Split Accessory Catalog for the complete accessory list
• Flexibility to accommodate to different applications
• Connect up to 5 indoor units to a single condensing unit
• Capacity range: 18 ~ 42 MBH
• Efficiency level: 16 SEER
• Refrigerant: R-410A
• Heat pump systems
Mu
lti-Sp
lits
14
Rated Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 18,000 BTUH
Indoor Model Number 4MXW8509A10N0BA 4MXW8512A10N0BA 4MXW8518A10N0BA
Rated Cooling Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 18,000 BTUH
Rated Heating Capacity (Btu/h) 9,800 BTUH 13,000 BTUH 19,800 BTUH
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Cooling Rated Power Input (W) 620 1000 1500
Heating Rated Power Input (W) 750 1200 2133
Cooling Nominal Input Current (A) 2.80 4.55 6.82
Heating Nominal Input Current (A) 3.04 5.20 9.7
Dehumidifying Volume (pt./h) 4.6 5.4 7.0
Cooling Fan Motor Speed (r/min) (SH/H/M/L) 1260 / 1100 / 950 / 750 1330 / 1100 / 950 / 750 1500 / 1200 / 1050 / 900
Heating Fan Motor Speed (r/min) (SH/H/M/L) 1320 / 1180 / 1050 / 950 1350 / 1200 / 1080 / 950 1500 / 1250 / 1150 / 1050
Sound PRESSURE Level dB (A)(SH/H/M/L) 42 / 38 / 35 / 32 44 / 39 / 36 / 33 49 / 44 / 40 / 35
Fuse (A) 3.15 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2
Max Height Distance (ft) 65 65 65
Max Length Distance (ft) 100 100 130
Uncrated Dimension (W/D/H) (inch) 33.3 x 7.1 x 10.8 33.3 x 7.1 x 10.8 37.0 x 7.9 x 11.7
Net Weight /Gross Weight (lbs) 22.0 / 28.6 22.0 / 28.6 28.6 x 37.4
Wireless Controller Optional (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1
See the Service First Mini-Split Accessory Catalog for the complete accessory list
Wireless controller (sold separately)
• High wall mounted
• Fan Speed: 4
• Condensate pump: Sold Separately
• Remote control capable (sold separately)
• Louver: adjustable and oscillating
• Capacity: 9k, 12k, 18k
Multi-Split Heat Pumps: Indoor High Wall Mounted
Mu
lti-
Sp
lits
15
Rated Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 18,000 BTUH
Indoor Model Number 4MXD8509A10N0AA 4MXD8512A10N0AA 4MXD8518A10N0AA
Cooling Capacity (Btu/h) 8,500 11,900 15,300
Heating Capacity (Btu/h) 9,500 13,100 18,700
Air Flow Volume (CFM) (H/M/L) 265 / 177 / 147 324 / 236 / 177 412 / 354 / 294
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Dehumidifying Volume (pt./h) 3.6 6.3 8.1
Fan Motor Speed (r/min) (H/M/L) 970 / 760 / 640 960 / 830 / 700 920 / 780 / 720
Sound PRESSURE Level dB (A)(H/M/L) 27 / 24 / 19 39 / 35 / 30 41 / 36 / 30
PBC Fuse Current (A) 3.15 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2
Uncrated Dimension (W/D/H) (inch) 27.65 x 24.21 x 7.87 27.56 x 24.21 x 7.87 35.43 x 24.21 x 7.87
Net Weight /Gross Weight (lbs) 48.5 / 59.5 50.7 / 63.9 59.5 / 79.4
Wireless Controller Optional (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1
See the Service First Mini-Split Accessory Catalog for the complete accessory list
Rated Capacity (Btu/h) 21,000 BTUH 24,000 BTUH
Indoor Model Number 4MXD8521A10N0AA 4MXD8242A10N0AA
Cooling Capacity (Btu/h) 20,400 23,800
Heating Capacity (Btu/h) 22,600 27,400
Air Flow Volume (CFM) (H/M/L) 589 / 442 / 324 589 / 442 / 324
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1
Dehumidifying Volume (pt./h) 4.23 5.28
Fan Motor Speed (r/min) (H/M/L) 985 / 800 / 680 985 / 800 / 680
Sound PRESSURE Level dB (A)(H/M/L) 1 42 / 37 / 32 42 / 37 / 32
PBC Fuse Current (A) 3.15 3.15
Outer Diameter Liquid Pipe (inch) 3/8 3/8
Outer Diameter Gas Pipe (inch) 5/8 5/8
Uncrated Dimension (W/D/H) (inch) 43.31 x 24.21 x 7.87 43.31 x 24.21 x 7.87
Net Weight /Gross Weight (lbs) 68.3 / 90.4 68.3 / 90.4
Wireless Controller Optional (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1
Nut withwasher
500 mm 250 mm
Springpad
>19.7 inch >9.8 inch
Wireless controller (sold separately)
Multi-Split Heat Pumps: Indoor Concealed
• Ceiling installation
• Fan speed: 3
• Condensate pump: included
• Wire controller: included
• Remote control capable (sold separately)
• Capacity: 9k, 12k, 18k, 21k, 24kWired controller included with Floor/Ceiling, Cassette, and Concealed units.
Mu
lti-Sp
lits
16
Rated Capacity (Btu/h) 12,000 BTUH 18,000 BTUH 24,000 BTUH
Indoor Model Number 4MXC8512A10N0AA* 4MXC8518A10N0AA* 4MXC8524A10N0AA**
Cooling Capacity (Btu/h) 12,000 14,400 22,800
Heating Capacity (Btu/h) 13,000 16,000 27,400
Air Flow Volume (CFM) (H/M/L) 353 / 294 / 265 353 / 294 / 265 694 / 560 / 500
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Dehumidifying Volume (pt./h) 6.3 8.1 11.2
Fan Motor Speed (r/min) (H/M/L) 845 / 700 / 600 845 / 700 / 600 620 / 570 / 520
Sound PRESSURE Level dB (A)(H/M/L) 46 / 42 / 37 46 / 42 / 37 39 / 37 / 35
PBC Fuse Current (A) 3.15 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4 3/8
Outer Diameter Gas Pipe (inch) 3/8 1/2 5/8
Uncrated Dimension (W/D/H) (inch) 22.44 x 22.44 x 9.06 22.44 x 22.44 x 9.06 33.07 x 33.07 x 9.45
Net Weight /Gross Weight (lbs) 39.7 / 50.7 39.7 / 50.7 66.1 / 83.8
Wireless Controller Optional (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1
* Order cassette cover 4MXL8518A10N0AA (Sold Separately) ** Order cassette cover 4MXL8524A10N0AA (Sold Separately) See the Service First Mini-Split Accessory Catalog for the complete accessory list
>20
mm
Wall surface
Wall surface
Wallsurface
Ground surface
H
mm 0081>
>59 inch
>1500 mm>59 inch
hcni 17>
>1500 mm
0.8
inch
>
Wireless controller (sold separately)
Multi-Split Heat Pumps: Indoor Cassette
• Ceiling installation
• Fan speed: 3
• Condensate pump: included
• Wire controller: included
• Remote control capable (sold separately)
• Louver: adjustable and oscillating
• Capacity: 12k, 18k, 24k
Wired controller included with Floor/Ceiling, Cassette, and Concealed units.
Mu
lti-
Sp
lits
17
Rated Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 18,000 BTUH
Indoor Model Number 4MXF8509A10N0AA 4MXF8512A10N0AA 4MXF8518A10N0AA
Cooling Capacity (Btu/h) 9,000 12,000 18,000
Heating Capacity (Btu/h) 9,500 13,000 19,800
Air Flow Volume (CFM) (H/M/L) 241 / 194 / 147 282 / 235 / 164 323 / 264 / 188
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Dehumidifying Volume (pt./h) 3.6 6.3 8.1
Fan Motor Speed (r/min) (H/M/L) 530 / 430 / 320 600 / 500 / 350 720 / 580 / 410
Sound PRESSURE Level dB (A)(H/M/L) 36 / 30 / 25 38 / 35 / 27 44 / 37 / 43
PBC Fuse Current (A) 3.15 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2
Uncrated Dimension (W/D/H) (inch) 27.56 x 23.62 x 8.46 27.56 x 23.62 x 8.46 27.56 x 23.62 x 8.46
Net Weight /Gross Weight (lbs) 33.1 / 39.7 33.1 / 39.7 33.1 / 39.7
Wireless Controller Optional (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1
See the Service First Mini-Split Accessory Catalog for the complete accessory list
Wireless controller (sold separately)
50 mm
or more300 mm
70 mm
or more
50 mm
or more
or more
2 inch
2.8 inch
1 feet
2 inch
Multi-Split Heat Pumps: Indoor Console
• Floor Installation
• Fan speed: 4
• Condensate pump: Sold Separately
• Wire controller: Not compatible
• Remote control capable (sold separately)
• Louver: adjustable and oscillating
• Capacity: 9k, 12k, 18k
Mu
lti-Sp
lits
18
Wireless controller (sold separately)
Rated Capacity (Btu/h) 9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
Cooling Capacity (Btu/h) 8,500 11,900 17,000 22,800
Heating Capacity (Btu/h) 9,500 13,100 18,700 27,400
Air Flow Volume (CFM) (H/M/L) 383 / 324 / 265 383 / 324 / 265 559 / 412 / 294 736 / 530 / 412
RATED Volts/PH 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1 208 / 230 / 1
Indoor Model Number 4MXX8509A10N0AA 4MXX8512A10N0AA 4MXX8518A10N0AA 4MXX8524A10N0AA
Dehumidifying Volume (pt./h) 3.6 3.6 8.1 11.2
Fan Motor Speed (r/min) (H/M/L) 690 / 610 / 480 690 / 610 / 480 985 / 800 / 680 985 / 800 / 680
Sound PRESSURE Level dB (A)(H/M/L) 40 / 37 / 33 40 / 37 / 33 45 / 41 / 38 48 / 43 / 29
PBC Fuse Current (A) 3.15 3.15 3.15 3.15
Outer Diameter Liquid Pipe (inch) 1/4 1/4 1/4 3/8
Outer Diameter Gas Pipe (inch) 3/8 3/8 1/2 5/8
Uncrated Dimension (W/D/H) (inch) 48.03 x 27.56 x 8.86 48.03 x 27.56 x 8.86 48.03 x 27.56 x 8.86 48.03 x 27.56 x 8.86
Net Weight /Gross Weight (lbs) 88.2 / 110.2 88.2 / 110.2 88.2 / 110.2 99.2 / 119.0
Wireless Controller Optional (sold separately) AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1 AREMOTE1AHAND1
See the Service First Mini-Split Accessory Catalog for the complete accessory list
>600 mm>1000 mm
>300 mm
>600 mm
>150
0 m
m
>300
mm
>600 mm>600 mm>1500 mm
>200 mm
POWER
RUN
TIMER
>24 inch >24 inch
>24 inch>24 inch >59 inch
>39 inch
>8 inch
>12 inch
>59
inch
>12
inch
Multi-Split Heat Pumps: Indoor Floor Ceiling
• Floor or Ceiling Installation
• Fan speed: 3
• Condensate pump: sold separately
• Wire controller: included
• Remote control capable (sold separately)
• Louver: adjustable and oscillating
• Capacity: 9k, 12k, 18k, 24kWired controller included with Floor/Ceiling, Cassette, and Concealed units.
Mu
lti-
Sp
lits
Many of our ductless units are ENERGY STAR® Qualified. Ask your dealer for details.
The ENERGY STAR program is a joint effort
between the U.S. Environmental Protection
Agency and the U.S. Department of Energy
designed to help consumers identify energy-
efficient products. When you see the ENERGY
STAR symbol, you know your ductless unit will
help reduce your energy consumption and
help the whole planet stay comfortable.
Designed for comfort. Built to last.
For more than a century, families have trusted
American Standard Heating & Air Conditioning to
keep their homes comfortable. Today, our home
comfort systems continue to push the boundaries of
efficiency and performance, while still delivering
on our proud history of quality, durability and
substantial value. Welcome your family home
to a higher standard of comfort. From American
Standard Heating & Air Conditioning.
American Standard Heating & Air Conditioning6200 Troup Highway • Tyler, Texas 75707
Since American Standard Heating & Air Conditioning has a policy of continuous product improvement, it reserves the right to change specifications and design without notice. Read important energy cost and efficiency information available from your dealer.
© 2013 American Standard Heating & Air Conditioning All rights reserved
Pub. No. 12-5059-01
Our dealers will put you in your comfort zone.Your independent American Standard Heating & Air Conditioning dealer is a highly trained professional with years of experience who’ll work with you every step of the way in choosing the system that’s right for you – from walking you through the entire purchasing process to conducting an in-depth analysis of your home and your comfort needs. Based on that information, your dealer will recommend a system that works best for your home. After all, the more efficient the system, the more comfortable you’ll be.
Take comfort in our peace-of-mind warranty.Your American Standard Heating & Air Conditioning Ductless System is about comfort and satisfaction. So is the Registered Limited Warranty supporting it.* Every Ductless System includes a 5 year Registered Limited Warranty on compressor and functional parts. See your independent American Standard Heating & Air Conditioning dealer for details.
* Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone at 800-554-8005, otherwise American Standard Heating & Air Conditioning’s Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on americanstandardair.com. For more information visit americanstandardair.com