Accelerating success.
AVAILABLE > KEYSTONE INDUSTRIAL PARK
95,360 SF Modern Warehouse AvailableDivisible to 40,000 SF220 Rittenhouse Circle, Bristol, PA
The foregoing information was furnished to us by sources which we deem to be reliable, but no warranty or representation is made as to the accuracy The foregoing information was furnished to us by sources which we deem to be reliable, but no warranty or representation is made as to the accuracy thereof. Subject to correction of errors, omissions, change of price, prior sale or withdrawal from market without notice. The aerial image is intended to provide a general outline of the subject property. It is not a survey nor should it be relied upon for purposes of determining property lines or boundaries.
FLOOR PLAN
REV
IDDESCRIPTION DATE
EX
ISTI
NG
BU
ILD
ING
REN
OV
ATI
ON
S
CUSHMAN WAKEFIELD
ISSUED FOR BID
CODE SUMMARY
A-002
PROJ. MGR.: JAMES A. SARRO, AIA
PROJECT #:
4452PROFESSIONAL SEAL
9 5 5 B E R K S H I R E B L V D ., S U I T E 1 0 1
W Y O M I S S I N G , P A 1 9 6 1 0
6 1 0 .3 7 6 .4 9 2 7
w w w .M G - A r c h i t e c t s .c o m
BAR IS ONE (1) INCH LONG ON ORIGINAL DRAWING
10
SHEET TITLE:
DRAWN BY: JS/BH
CLIENT PROJ #: -
DATE: 04/30/2020
SCOTT O. GRAHAM AIA, LEED AP+
COPYRIGHT © 2020 ALL RIGHTS RESERVED NEITHER ALL NOR ANY
PART OF THIS DOCUMENT MAY BE AMENDED, REPRODUCED,
COPIED OR USED IN ANY FORM OR MANNER EXCEPT PURSUANT
TO CONTRACT OR WITH THE SPECIFIC WRITTEN PERMISSION OF
MUHLENBERG GREENE ARCHITECTS,LTD. THESE PLANS, DESIGNS
AND SUBJECT MATTER ARE NOT TO BE REPRODUCED, CHANGED
OR COPIED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE
ASSIGNED TO ANY THIRD PARTY WITHOUT FIRST OBTAINING THE
EXPRESS WRITTEN PERMISSION AND CONSENT OF MUHLENBERG
GREENE ARCHITECTS, LTD. THIS DOCUMENT IS AN ARTICLE OF
SERVICE AND THE COPYRIGHT AND OTHER PROPERTY RIGHTS ARE
EXPRESSLY RESERVED BY MUHLENBERG GREENE ARCHITECTS, LTD.
CU
SH
MA
N W
AK
EFIE
LD
220 R
ITTE
NH
OU
SE C
IRC
LE
BR
ISTO
L, P
A
contact: JIM ADAMS
1650 MARKET ST.
PHILADELPHIA, PA 19103
215.963.4026
VERIFY SCALE
P.M. e-MAIL: [email protected]
2020-04-29_4452_220 Rittenhouse.pln | P:\4452 C&W Rittenhouse Tenant Improvements\2020-04-29_4452_220 Rittenhouse.pln | 5/1/2020 | 10:44 AM
A R C H I T E C T U R A L D E S I G N
I N T E R I O R D E S I G N
C O D E A N A L Y S I S
P L A N N I N G S E R V I C E S
R E P O R T S A N D S T U D I E S
E N G I N E E R I N G S E R V I C E S
H I S T O R I C P R E S E R V A T I O N
25
180
36
41'
5
LIFE SAFETY LEGEND
SMOKE PARTITION
30 MIN. FIRE-RATED
60 MIN. FIRE-RATED
120 MIN. FIRE-RATEDSCHEDULED EGRESS LOAD
MAX. DOOR/STAIR EGRESS CAPACITY
EGRESS WIDTH (INCHES)
EGRESS TRAVEL DISTANCE TO EXIT
OCCUPANTS ON EGRESS PATH
EGRESS PATH
EXIT CAPACITY
ACCESSIBLE ROUTE
REQUIRED MINIMUM
MANEUVERING SPACE
25
160
32
25
160
32
25
160
32
25
160
32
25
320
64
25
160
32
A B C D E F G H I
1
2
3
4
5
6
7
8
9
322'-0" +/-EXISTING BUILDING
32
2'-0
" +
/-EX
ISTI
NG
BU
ILD
ING
.
90 MIN. RATED
(EXISTING)
90 MIN. RATED
(EXISTING)
STAIR EGRESS
CAPACITY:
60" WIDE/200 OCC.
DF
SS
CS-1
CS-2
CS-2
CS-2CS-2
CS-2
CS-2CS-2
CS-2
CS-3
CS-5
CS-3
CS-3 CS-3
90 MIN. RATED
(EXISTING)
180 MIN. RATED
(EXISTING)
180 MIN. RATED
(EXISTING)
SEPARATION NOT
REQUIRED BETWEEN USES
2.41.10
EXIT EXIT EXIT
EXIT
EXIT
EXIT
EXIT
USE GROUP B
USE GROUP S1
EXIT
25
160
32
.
90 MIN. RATED
(EXIST.)
STAIR EGRESS
CAPACITY:
60" WIDE/200 OCC.
SS
CS-3
CS-3
USE GROUP B
25
160
32
60
" M
AX
48
" M
IN
9" MIN.
18
" M
IN.
18" MIN.
45.00°
CL
LETTERING
HERE
CLCLEARANCE CENTERED ON
RAISED CHARACTERS1FIRST FLOOR LIFE SAFETY PLANSCALE: 1/16" = 1'-0"
2SECOND FLOOR
LIFE SAFETY PLANSCALE: 1/16" = 1'-0"
SCALE: 3/8" = 1'-0"3CODE SIGNAGE LOCATION
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES: IPC TABLE 403.1
REQUIRED
WATER CLOSETS LAVATORIES
PROVIDED REQUIRED
DRINKING FOUNTAINS
(DF)OCCUPANCY
LOAD
(PER FLOOR)
41FIRST (B USE)
PLUMBING CODE SUMMARY - IPC 2015
FLOOR MEN WOMEN TOTAL
2
REQUIRED MEN WOMEN TOTAL
2
PROVIDED PROVIDED
REQUIRED
ID OR POSTED OCCUPANT LOAD
ID
CODE REQUIRED SIGNAGE - IBC 2015
SIGNAGE TEXT
DUPLICATE
BRAILLE TEXT TACTILE TEXT ISA
CS-1 BUILDING ADDRESS NUMBER NONOYES
CS-2 EXIT/EXIT ACCESS (IN ADDITION TO ILLUMINATED SIGN) YESYESYES
CS-3 TOILET ROOM (MENS/WOMENS/UNISEX) NOYESYES
CS-4 FIRE EXTINGUISHER NOYESYES
GENERAL SIGNAGE NOTES
1. ALL REQUIRED ACCESSIBILITY SIGNAGE SHALL FOLLOW THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IN SIZE, COLOR, PROPORTIONS, AND TEXT (TACTILE AND BRAILE
TEXT REQUIREMENTS).
2. ALL SIGNAGE SHALL FOLLOW IBC 2015, ICC A117.1- 2009, AND 2010 ADA STANDARDS/REQUIREMENTS.
3. GENERAL CONTRACTOR SHALL VERIFY SIGNAGE QUANTITIES.
4. REFER TO LIFE SAFETY PLANS FOR SIGNAGE LOCATIONS. GENERAL CONTRACTOR SHALL VERIFY/CONFIRM FINAL LOCATIONS OF ALL SIGNS WITH AUTHORITY HAVING
JURISDICTION.
5. SIGNAGE FOR RATED BARRIERS SHALL BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL OR PARTITION AND SPACED AT INTERVALS NOT EXCEEDING 30 FEET
ALONG THE WALL OR PARTITION. THE LETTERING SHALL NOT BE LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8" STROKE IN A CONTRASTING COLOR.
CS-5 RATED BARRIERS NONONO
IFC SECTION 505.1
IBC SECTION 1013
IBC SECTION 2902.4
IFC SECTION 906.6
IBC SECTION 703.7 (SEE NOTE #5)
SIZE
9"x6"
4"x6"
6"x9"
3"x6"
4"x6"
ZONING &
BUILDING CODE
SUMMARY
IBC 2015
CONSTRUCTION TYPE
AUTOMATIC SPRINKLER SYSTEM
SECTION 602 AND TABLE 601
SECTION 903
IIB (ASSUMED EXISTING)
MEANS OF EGRESS IBC 2015 REQUIRED PROVIDED
OCCUPANCY LOAD SECTION 1004 AND TABLE 1004.1.1
EGRESS WIDTH
WIDTH PER OCCUPANT
STAIRWAYS
OTHER EGRESS COMPONENTS
STAIRWAYS
STAIRWAY WIDTH
AREA OF REFUGE
AREA OF RESCUE ASSISTANCE
MAXIMUM PATH OF COMMON EGRESS TRAVEL
MAXIMUM EXIT ACCESS TRAVEL DISTANCE
MINIMUM CORRIDOR WIDTH
MAXIMUM DEAD END
MINIMUM NUMBER OF EXITS
SECTION 1005
SECTION 1005.1
SECTION 1005.1
SECTION 1009
SECTION 1007.3 AND 1009.1
SECTION 1007.3 AND 1007.6
SECTION 1007.2 AND 1007.7
SECTION 1014.3
SECTION 1016 & TABLE 1016.1
SECTION 1018.2
SECTION 1018.4
SECTION 1021 & TABLE 1021.1
SEE LIFE SAFETY PLANS
0.3 INCHES PER OCCUPANT
0.2 INCHES PER OCCUPANT
44"
NO
NO
100'
200'
44"
50'
2 (1 FIRST FLR./1 SECOND FLOOR)
SEE LIFE SAFETY PLANS
SEE LIFE SAFETY PLANS
60" (EXISTING)
NOT REQUIRED
NOT REQUIRED
SEE LIFE SAFETY PLANS
SEE LIFE SAFETY PLANS
N/A
N/A
SEE LIFE SAFETY PLANS
USE AND OCCUPANCY CHAPTER 3
LEVEL OF ALTERATION
IEBC 2015
CHAPTER 7
BUILDING AND PROJECT DATA
LEVEL 2
B/S1 (EXISTING OCCUPANCY -NON-SEPERATED MIXED USE)
-
BUILDING DESCRIPTION AND USE 2 STORY EXISTING BLDG. FLEX BUILDING
BUILDING HEIGHT
REQUIRED PROVIDED
YES
BUILDING STORIES
TABLE 503 40' MAX.
TABLE 503 22
EXISTING BUILDING AREA
FIRST FLOOR AREA 93,227 SQ. FT.
SECOND FLOOR AREA 2,784 SQ. FT.
OCCUPANCY CALCS OCCUPANT LOAD
APPX. 24'-0"
YES (EXISTING)
WAREHOUSE
AREA REQUIRED
89,208 SQ. FT. (GROSS) 178.4 (179)500 SQ. FT. / PERSON (GROSS)
ALL OCCUPANCIES 96,011 SQ. FT. (GROSS) 248
APPLICABLE CODES AND ORDINANCES
2015 IBC: FAMILY OF CODES
ANSI 117.1, 2009 EDITION: ALL APPLICABLE CHAPTERS
2,784 SQ. FT. (GROSS) 27.8 (28)100 SQ. FT. / PERSON (GROSS)
FIRST FLOOR OFFICE (BUSINESS AREA) 4,019 SQ. FT. (GROSS) 40.2 (41)100 SQ. FT. / PERSON (GROSS)
PROJECT SCOPE:INTERIOR MODIFICATIONS AND SITE IMPROVEMENTS TO ACCOMODATE NEW LOADING DOCKS. SCOPE INCLUDES REMOVAL OF A PORTION OF EXISTING
OFFICES AND NEW LOADING DOCKS.
SECOND FLOOR OFFICE (BUSINESS AREA)
FIRST (S1 USE)
SECOND (B USE)
179
28 2 1 2 3 2 1 2 3
2
1 1 2 1 1 2
1 1
1 11 12 2 4 2 2 2 4
GENERAL SHEET NOTES1. THIS PLAN IS FOR THE BUILDING CORE AND SHELL MODIFICATIONS ONLY.
2. THE BUILDING IS CURRENTLY UNOCCUPIED. OCCUPANCY PLANS WILL BE PROVIDED TO THE
LOCAL AHJ FOR REVIEW BY THE INDIVIDUAL TENANTS AS THEY BECOME AVAILABLE,
PROVIDED
SERVICE SINK
(SS)
AUTHORITY HAVING JURISDICTION
BRISTOL TOWNSHIP
2501 BATH ROAD, BRISTOL, PA 19007
P: (215) 785-0500
FIRST FLOOR
AVAILABLE95,360 SF
40,000 SF 52,800 SF
SECOND FLOOR2,500 SF
COLLIERS INTERNATIONALTen Penn Center
1801 Market Street, Suite 500Philadelphia, PA 19103
www.colliers.com/philadelphia
> Modern 95,360 SF single-story warehouse situated on 6.79 acres
> Divisible to 40,000 SF
> 23' sloping to 21' ceiling height
> 40' x 40' column spacing
> Heavy power infrastructure for manufacturing uses
> Zoning: PI (planned industrial)
> Economic incentives available – located in the Enterprise Zone
> 100 + car parking
> 10 + trailer stalls available
> Permitted for (11) EDU sewer discharge
> Excellent infrastructure to support water intensive industries, including but not limited to: Pharmaceutical, Food Service, Beverage, Manufacturing, Textile, Etc.
BUILDING FEATURES
JIM SCOTT CCIMSenior Managing DirectorMobile: +1 215 932 [email protected]
FIRST FLOOR
$1,000,000 OF CAPITAL IMPROVEMENTS UNDERWAY!
Expansion of loading (to 11 tailgates)
New dock door packages LED lighting Sprinkler upgrade
Office renovations Exterior renovations & landscaping
New asphalt/truck court
COLLIERS INTERNATIONALTen Penn Center1801 Market Street, Suite 500Main: +1 215 925 4600www.colliers.com/philadelphia
For more information contact us: 413 offices in 69 countries on 6 continents• $2.7 billion in annual revenue
• 2 billion square feet under management
• Over 15,000 professionals
UNITED STATES:
Colliers International | Philadelphia
Philadelphia, PA (headquarters)TEL +1 215 925 4600
Allentown, PATEL +1 610 770 3600
West Conshohocken, PATEL +1 610 684 1850
Harrisburg, PATEL +1 717 730 3752
Wilmington, DETEL +1 302 425 4000
Mount Laurel, NJTEL +1 856 234 9300
www.colliers.com/philadelphia
The foregoing information was furnished to us by sources which we deem to be reliable, but no warranty or representation is made as to the accuracy thereof. Subject to correction of errors, omissions, change of price, prior sale or withdrawal from market without notice. The aerial image is intended to provide a general outline of the subject property. It is not a survey nor should it be relied upon for purposes of determining property lines or boundaries.