40
Honeywell Primary Control Cross Reference 95-6855-15 Page 1 R177, R180, R187, R190B, RA190B, R190C, R887, R890B RA890B, R890C, RA890C, RA890XB,XC, RA890D Pages 2–4 RA890E Pages 5–7 RA890F Pages 8–9 RA890G Page 10 RA890H,J,K Page 11 R485 Pages 12–13 R4075 Pages 14–15 R4138 Pages 16–17 R4795 Pages 18–19 R7023 Page 20 R7795 Pages 21–24 7800 SERIES Primary Controls Pages 25–26 FIREYE TM TFM1,2,3 and UVM1,2,3,5 Pages 27–28 MII Pages 29–35 MicroM

95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

Honeywell Primary ControlCross Reference

95-6855-15

Page 1 R177, R180, R187, R190B, RA190B, R190C, R887, R890B RA890B, R890C, RA890C, RA890XB,XC, RA890D

Pages 2–4 RA890E

Pages 5–7 RA890F

Pages 8–9 RA890G

Page 10 RA890H,J,K

Page 11 R485

Pages 12–13 R4075

Pages 14–15 R4138

Pages 16–17 R4795

Pages 18–19 R7023

Page 20 R7795

Pages 21–24 7800 SERIES Primary Controls

Pages 25–26 FIREYETM TFM1,2,3 and UVM1,2,3,5

Pages 27–28 MII

Pages 29–35 MicroM

Page 2: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60
Page 3: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

1 95-6855—15

Honeywell Primary Control Cross Reference

TABLE 1—CROSS REFERENCEDevice To Be

ReplacedCurrent

Replacement7800 Series

Replacementb c

WiringDesignation andTerminal Number

Comments

R177A a RA890F RM7890A1015 power—1,2limit—1-5motor—3

ignition—4controller—R,W,B

detector—F,G

Remove Series 10 Controller and rewire.Same as RA890F except does not have “proof of

flame” terminal (terminal 5 on RA890E,F).Requires Q270A Subbase with RA890F.

Requires Q7800F1004 Subbase with RM7890A1015.

R180A a RA890F RM7890A1015 power—1,2jumper—1-3

limit, main valve—4controller—R,W,B

detector—F,G

Continuous pilot applications only.Remove Series 10 Controller and rewire.Requires Q270A Subbase with RA 890F.

Requires Q7800F1004 Subbase with RM7890A1015.

R180B a RA890F RM7890A1015 power —1,2limit, main valve—5motor, pilot valve—3

ignition—4controller—R,W,B

detector—F,G

Functionality same as RA890F.Remove Series 10 Controller and rewire.Requires Q270A Subbase with RA890F.

Requires Q7800F1004 Subbase with RM7890A1015.

R187A a RA890F RM7890A10105 power—1,2limit—1-5motor—3

ignition—4controller—R,W,B

detector—F,G

Remove Series 10 Controller and rewire.Requires Q270A Subbase with RA890F.

Requires Q7800F1004 Subbase with RM7890A1015

R190B,RA190B

a RA890F RM7890A1015 See R180B Remove Series 10 Controller and rewire.Requires Q270A Subbase with RA890F.

Requires Q7800F1004 Subbase with RM7890A1015.R190C None RM7838A,B

RM7890B1014See Modernization Wiring Information

section

Used in W124 and ID051 panels.See Modernization Wiring Information section.

R887A a RA890F RM7890A1015 power—1,2limit—1-5motor—3

ignition—4controller—T,Tdetector—F,G

Rewire.Requires Q270A Subbase with RA89OF.

Requires Q7800F1004 Subbase with RM7890A1015.

R890B,RA890B

a RA890F RM7890A1015 power—1,2limit—1

motor, pilot valve—3ignition—4

main valve—5controller—6jumper—T,T

detector—F,G

Requires Q7800F1004 Subbase with RM7890A1015.

R890C,RA890C

RA890F RM7890A1015 Same as R890B,RA890B

Requires Q7800Fl004 Subbase with RM7890A1015.

RA890XB RA890F RM7890A1015 Same as R890B Requires Q7800F1004 Subbase with RM7890A1015.RA890XC RA890B

RA890D None RM7840M1017 Same as R890B,RA890B exceptcontroller alwayson terminal 6 andLF switch to T,T

Requires Q520A Subbase and R7247A AmplifierRequires rewire with Q7800A1005 Subbase and

R7847A1009 or R7847B1007 Amplifier withRM7840M1017.

FOOTNOTES:a Refer to Primary Cross-Reference section to select proper voltage, frequency, and timings.b Select R7847A1025, 1033 or R7847B1023, 1031 Amplifier. JR2 must be clipped when using 3 second amplifier.c See Modernization Wiring Information section.

Page 4: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 2

Honeywell Primary Control Cross ReferenceTA

BLE

2—

RA

890E

CR

OSS

REF

EREN

CE

Dev

ice

to b

e R

epla

ced

R

A89

0E

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Cur

rent

RA

890F

7800

Ser

ies

b c

hA

mpl

ifier

f

Volta

ge (

Vac)

Freq

uenc

y (H

z)Sa

fety

Sw

itch

Tim

ing

(Sec

s)FF

RT

(sec

)A

larm

Con

tact

s

g

1009

RA

890F

1338

RM

7890

A10

31R

7847

A10

2512

060

300.

810

17N

one

a e

EC

7890

A10

11R

7847

A10

2520

860

300.

810

25N

one

e

EC

7890

A10

11R

7847

A10

2524

060

300.

810

33R

A89

0F13

38R

M78

90A

1031

R78

47A

1025

120

5030

0.8

1041

Non

ee

E

C78

90A

1011

R78

47A

1025

220

5030

0.8

1058

Non

ee

E

C78

90A

1011

R78

47A

1025

240

5030

0.8

1066

RA

890F

1346

RM

7890

A10

31R

7847

A10

3312

060

302-

410

74N

one

a e

EC

7890

A10

11R

7847

A10

3320

860

302-

410

82N

one

e

EC

7890

A10

11R

7847

A10

3324

060

302-

410

90R

A89

0F13

46R

M78

90A

1031

R78

47A

1033

120

5030

2-4

1108

Non

ee

E

C78

90A

1011

R78

47A

1033

220

5030

2-4

1116

Non

ee

E

C78

90A

1011

R78

47A

1033

240

5030

2-4

1124

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

060

150.

811

32N

one

a e

EC

7890

A10

11R

7847

A10

2520

860

150.

811

40N

one

e

EC

7890

A10

11R

7847

A10

2524

060

150.

811

57R

A89

0F12

70d

R

M78

90A

1015

R78

47A

1025

120

5015

0.8

1165

RA

890F

1304

e

EC

7890

A10

11R

7847

A10

2522

050

150.

811

73N

one

e

EC

7890

A10

11R

7847

A10

2524

050

150.

811

81R

A89

0F12

88d

R

M78

90A

1015

R78

47A

1033

120

50/6

015

2-4

1199

Non

ea

e E

C78

90A

1011

R78

47A

1033

208

50/6

015

2-4

1207

Non

ee

E

C78

90A

1011

R78

47A

1033

240

50/6

015

2-4

1215

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

152-

412

23N

one

e

EC

7890

A10

11R

7847

A10

3322

050

152-

412

31R

A89

0F13

87e

E

C78

90A

1011

R78

47A

1033

240

5015

2-4

1249

RA

890F

1338

RM

7890

A10

31R

7847

A10

2512

050

/60

300.

8N

.O.

1256

Non

ea

e E

C78

90A

1011

R78

47A

1025

208

50/6

030

0.8

N.O

.12

64N

one

e

EC

7890

A10

11R

7847

A10

2524

050

/60

300.

8N

.O.

1272

Non

ee

E

C78

90A

1011

R78

47A

1025

220

5030

0.8

N.O

.12

80R

A89

0F13

46R

M78

90A

1031

R78

47A

1033

120

50/6

030

2-4

N.O

.12

98N

one

a e

EC

7890

A10

11R

7847

A10

3320

860

302-

4N

.O.

1306

Non

ee

E

C78

90A

1011

R78

47A

1033

240

6030

2-4

N.O

.13

14R

A89

0F13

46R

M78

90A

1031

R78

47A

1033

120

5030

2-4

N.O

.13

22N

one

e

EC

7890

A10

11R

7847

A10

3322

050

302-

4N

.O.

1330

Non

ee

E

C78

90A

1011

R78

47A

1033

240

5030

2-4

N.O

.

1348

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8N

.O.

1355

Non

ea

e E

C78

90A

1011

R78

47A

1025

208

50/6

015

0.8

N.O

.

1363

Non

ee

E

C78

90A

1011

R78

47A

1025

240

50/6

015

0.8

N.O

.

Page 5: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

3 95-6855—15

Honeywell Primary Control Cross Reference

TAB

LE 2

—R

A89

0E C

RO

SS R

EFER

ENC

ED

evic

e to

be

Rep

lace

d

RA

890E

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Cur

rent

RA

890F

7800

Ser

ies

b c

hA

mpl

ifier

f

Volta

ge (

Vac)

Freq

uenc

y (H

z)Sa

fety

Sw

itch

Tim

ing

(Sec

s)FF

RT

(sec

)A

larm

Con

tact

s

g

1371

Non

ee

E

C78

90A

1011

R78

47A

1025

240

5015

0.8

N.O

.

1389

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

/60

152-

4N

.O.

1397

RA

890F

1296

a e

EC

7890

A10

11R

7847

A10

3320

850

/60

152-

4N

.O.

1405

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

/60

152-

4N

.O.

1413

RA

890F

1338

RM

7890

A10

31R

7847

A10

2512

060

300.

8N

.C.

1421

Non

ea

e E

C78

90A

1011

R78

47A

1025

208

6030

0.8

N.C

.

1439

Non

ee

E

C78

90A

1011

R78

47A

1025

240

6030

0.8

N.C

.

1447

RA

890F

1346

RM

7890

A10

31R

7847

A10

3312

060

302-

4N

.C.

1454

Non

ee

E

C78

90A

1011

R78

47A

1033

240

6030

2-4

N.C

.

1462

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8N

.C.

1470

Non

ea

e E

C78

90A

1011

R78

47A

1025

208

50/6

015

0.8

N.C

.

1488

Non

ee

E

C78

90A

1011

R78

47A

1025

240

50/6

015

0.8

N.C

.

1496

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

/60

152-

4N

.C.

1504

RA

890F

1296

a e

EC

7890

A10

11R

7847

A10

3320

850

/60

152-

4N

.C.

1512

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

/60

152-

4N

.C.

1520

Non

ed

R

M78

90A

1015

R78

47A

1033

120

6045

2-4

N.O

.

1538

Non

ee

E

C78

90A

1011

R78

47A

1033

240

6045

2-4

N.O

.

1546

Non

ee

E

C78

90A

1011

R78

47A

1025

240

5030

0.8

N.O

.

1553

Non

ea

e E

C78

90A

1011

R78

47A

1025

208

5030

0.8

1561

RA

890F

1304

e

EC

7890

A10

11R

7847

A10

2522

050

150.

8N

.O.

1579

Non

ee

E

C78

90A

1011

R78

47A

1025

220

5015

0.8

N.C

.

1587

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

152-

4N

.C.

1595

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

152-

4N

.C.

1603

RA

890F

1338

RM

7890

A10

31R

7847

A10

2512

050

/60

300.

8S

pdt

1611

Non

ee

E

C78

90A

1011

R78

47A

1025

220

5030

0.8

Spd

t

1629

RA

890F

1346

RM

7890

A10

31R

7847

A10

3312

050

/60

302-

4S

pdt

1637

Non

ee

E

C78

90A

1011

R78

47A

1033

240

50/6

030

2-4

Spd

t

1645

RA

890F

1346

RM

7890

A10

31R

7847

A10

3312

050

302-

4S

pdt

1652

Non

ee

E

C78

90A

1011

R78

47A

1033

220

5030

2-4

Spd

t

1660

Non

ee

E

C78

90A

1011

R78

47A

1033

240

5030

2-4

Spd

t

1678

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8S

pdt

1686

Non

ea

e E

C78

90A

1011

R78

47A

1025

208

50/6

015

0.8

Spd

t

1694

Non

ee

E

C78

90A

1011

R78

47A

1025

240

50/6

015

0.8

Spd

t

1702

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

/60

152-

4S

pdt

1710

RA

890F

1296

a e

EC

7890

A10

11R

7847

A10

3320

850

/60

152-

4S

pdt

(con

tinue

d)

Page 6: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 4

Honeywell Primary Control Cross Reference

FOO

TNO

TES

:a

E

C78

90 o

pera

ting

volta

ge is

187

Vac

to 2

64 V

ac 5

0/60

Hz

b

Sug

gest

ed R

epla

cem

ent D

evic

e ha

s a

10 S

econ

d S

afet

y S

witc

h Ti

me

c

Sel

ect W

iring

Sub

base

Q

7800

A10

05 fo

r Pan

el M

ount

ing

- Wiri

ng c

onve

rsio

n re

quire

dQ

7800

B10

03 fo

r Bur

ner/W

all M

ount

ing

- Wiri

ng c

onve

rsio

n re

quire

dQ

7800

F100

4 - M

ount

s to

exi

stin

g w

iring

sub

base

d

Alte

rnat

e R

epla

cem

ent R

M78

90B

1014

. R

M78

90B

has

a s

hutte

r out

put t

erm

inal

.

e

Alte

rnat

e R

epla

cem

ent E

C78

90B

1010

. E

C78

90B

has

a s

hutte

r out

put t

erm

inal

. A 2

40 to

120

10

va m

inim

um tr

ansf

orm

er w

ill b

e ne

eded

if d

etec

tor s

yste

m c

hang

ed to

shu

tter t

ype

dete

ctor

.f

Fo

r Sen

sor L

eadw

ire ru

ns g

reat

er th

an 5

0fee

t sel

ect a

ppro

pria

te a

mpl

ifier

.R

7847

A10

75 fo

r 0.8

Fla

me

Failu

re R

espo

nse

R78

47A

1082

for 3

.0 F

lam

e Fa

ilure

Res

pons

eg

78

00 S

erie

s ha

s on

ly a

line

vol

tage

out

put a

larm

. h

R

M78

90A

1056

or R

M78

90B

1048

can

als

o re

plac

e th

e R

M78

90A

1015

. A ju

mpe

r bet

wee

n te

rmin

als

3 an

d 20

will

nee

d to

be

adde

d.

TAB

LE 2

—R

A89

0E C

RO

SS R

EFER

ENC

ED

evic

e to

be

Rep

lace

d

RA

890E

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Cur

rent

RA

890F

7800

Ser

ies

b c

hA

mpl

ifier

f

Volta

ge (

Vac)

Freq

uenc

y (H

z)Sa

fety

Sw

itch

Tim

ing

(Sec

s)FF

RT

(sec

)A

larm

Con

tact

s

g

1728

RA

809F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

/60

152-

4S

pdt

1736

Non

ea

e E

C78

90A

1011

R78

47A

1025

208

50/6

030

0.8

Spd

t

1744

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

152-

4S

pdt

1751

Non

ee

E

C78

90A

1011

R78

47A

1025

240

50/6

030

0.8

Spd

t

1769

Non

ee

E

C78

90A

1011

R78

47A

1033

220

5015

2-4

Spd

t

1777

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

152-

4S

pdt

1785

Non

ee

E

C78

90A

1011

R78

47A

1033

220

5015

2-4

N.O

.

1793

RA

890F

1304

e

EC

7890

A10

11R

7847

A10

2522

050

150.

8N

.O.

1801

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

152-

4

1819

Non

ee

E

C78

90A

1011

R78

47A

1033

220

5015

2-4

1827

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

152-

4

1835

Non

ee

E

C78

90A

1011

R78

47A

1033

220

5030

2-4

1843

Non

ee

E

C78

90A

1011

R78

47A

1033

240

5030

2-4

1850

Non

ee

E

C78

90A

1011

R78

47A

1025

240

50/6

030

0.8

Fung

us-P

roof

1868

Non

ea

e E

C78

90A

1011

R78

47A

1025

208

50/6

030

0.8

Fung

us-P

roof

1876

RA

890F

1304

e

EC

7890

A10

11R

7847

A10

2522

050

150.

8S

pdt

1884

Non

ee

E

C78

90A

1011

R78

47A

1025

240

50/6

030

0.8

Spd

t

1892

Non

e10

050

/60

150.

8S

peci

al fo

r Ya

mat

ake

(Jap

an)

1900

Non

ea

e E

C78

90A

1011

R78

47A

1025

200

50/6

015

0.8

Spe

cial

for

Yam

atak

e (J

apan

)19

18R

A89

0F12

70d

R

M78

90A

1015

R78

47A

1025

120

50/6

015

0.8

1926

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

/60

152-

4

1934

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8S

pdt

1942

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

/60

152-

4S

pdt

1959

Non

e10

050

/60

152-

4S

pdt

Spe

cial

for

Yam

atak

e (J

apan

)19

67N

one

e

EC

7890

A10

11R

7847

A10

3322

050

302-

4

1975

Non

ea

e E

C78

90A

1011

R78

47A

1033

208

6015

2-4

Spd

t

(con

tinue

d)

Page 7: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

5 95-6855—15

Honeywell Primary Control Cross Reference

TAB

LE 3

—R

A89

0F C

RO

SS R

EFER

ENC

E

Dev

ice

to b

e R

epla

ced

R

A89

0F

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Cur

rent

R

A89

0F78

00 S

erie

s

b c

h

Am

plifi

er

fVo

ltage

(V

ac)

Freq

uenc

y

(Hz)

Safe

ty S

witc

h Ti

min

g (S

ecs)

FFR

T (s

ec)

Ala

rm

Con

tact

s

g

1007

RA

890F

1338

RM

7890

A10

31R

7847

A10

2512

050

/60

300.

810

15R

A89

0F13

46R

M78

90A

1031

R78

47A

1033

120

50/6

030

310

23R

A89

0F12

70d

R

M78

90A

1015

R78

47A

1025

120

50/6

015

0.8

1031

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

/60

153

1049

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8S

pdt

1056

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

/60

153

Spd

t10

64R

A89

0F12

70d

R

M78

90A

1015

R78

47A

1025

120

50/6

015

0.8

Spd

t10

72R

A89

0F12

88d

R

M78

90A

1015

R78

47A

1033

120

50/6

015

3S

pdt

1080

RA

890F

1296

a e

EC

7890

A10

11R

7847

A10

3320

850

/60

153

Spd

t10

98R

A89

0F13

04e

E

C78

90A

1011

R78

47A

1025

220

50/6

015

0.8

Spd

t11

06N

ON

Ee

E

C78

90A

1011

R78

47A

1025

240

50/6

015

0.8

1114

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

/60

153

1122

RA

890F

1338

RM

7890

A10

31R

7847

A10

2512

050

/60

300.

8S

pdt

1130

RA

890F

1346

RM

7890

A10

31R

7847

A10

3312

050

/60

303

Spd

t11

48N

ON

Ee

E

C78

90A

1011

R78

47A

1025

240

50/6

030

0.8

Spd

t11

55N

ON

Ee

E

C78

90A

1011

R78

47A

1033

240

50/6

030

3S

pdt

1163

NO

NE

e

EC

7890

A10

11R

7847

A10

2524

050

/60

150.

8S

pdt

1171

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

/60

153

Spd

t11

89N

ON

Ee

E

C78

90A

1011

R78

47A

1025

240

50/6

030

0.8

Spd

t11

97N

ON

Ee

E

C78

90A

1011

R78

47A

1033

240

50/6

030

312

05N

ON

EN

ON

E10

050

/60

153

Spd

tS

peci

al fo

r Yam

atak

e (J

apan

)12

13N

ON

Ee

E

C78

90A

1011

R78

47A

1033

220

50/6

015

3S

pdt

1221

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

/60

153

Spd

t12

39R

A89

0F13

38R

M78

90A

1031

R78

47A

1025

120

50/6

030

0.8

1247

RA

890F

1346

RM

7890

A10

31R

7847

A10

3312

050

/60

303

1254

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

812

62R

A89

0F12

88d

R

M78

90A

1015

R78

47A

1033

120

50/6

015

312

70R

A89

0F12

70d

R

M78

90A

1015

R78

47A

1025

120

50/6

015

0.8

Spd

t12

88R

A89

0F12

88d

R

M78

90A

1015

R78

47A

1033

120

50/6

015

3S

pdt

1296

RA

890F

1296

a e

EC

7890

A10

11R

7847

A10

3320

850

/60

153

Spd

t13

04R

A89

0F13

04e

E

C78

90A

1011

R78

47A

1025

220

50/6

015

0.8

Spd

t13

12N

ON

Ee

E

C78

90A

1011

R78

47A

1025

240

50/6

015

0.8

1320

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

/60

153

1338

RA

890F

1338

RM

7890

A10

31R

7847

A10

2512

050

/60

300.

8S

pdt

1346

RA

890F

1346

RM

7890

A10

31R

7847

A10

3312

050

/60

303

Spd

t13

53N

ON

Ee

E

C78

90A

1011

R78

47A

1025

240

50/6

030

0.8

Spd

t

Page 8: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 6

Honeywell Primary Control Cross ReferenceTA

BLE

3—

RA

890F

CR

OSS

REF

EREN

CE

Dev

ice

to b

e R

epla

ced

R

A89

0F

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Cur

rent

R

A89

0F78

00 S

erie

s

b c

h

Am

plifi

er

fVo

ltage

(V

ac)

Freq

uenc

y

(Hz)

Safe

ty S

witc

h Ti

min

g (S

ecs)

FFR

T (s

ec)

Ala

rm

Con

tact

s

g

1361

NO

NE

e

EC

7890

A10

11R

7847

A10

3324

050

/60

303

Spd

t13

79N

ON

Ee

E

C78

90A

1011

R78

47A

1025

240

50/6

015

0.8

Spd

t13

87R

A89

0F13

87e

E

C78

90A

1011

R78

47A

1033

240

50/6

015

3S

pdt

1395

NO

NE

e

EC

7890

A10

11R

7847

A10

2524

050

/60

300.

814

03N

ON

Ee

E

C78

90A

1011

R78

47A

1033

240

50/6

030

314

11N

ON

EN

ON

E10

050

/60

153

Spd

tS

peci

al fo

r Yam

atak

e (J

apan

)14

29N

ON

Ee

E

C78

90A

1011

R78

47A

1033

220

50/6

015

3S

pdt

1437

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8S

pdt

1445

RA

890F

1387

e

EC

7890

A10

11R

7847

A10

3324

050

/60

153

Spd

t14

52N

ON

Ea

e E

C78

90A

1011

R78

47A

1025

208

50/6

015

0.8

Spd

t14

60N

ON

EN

ON

E10

050

/60

150.

8S

pdt

1478

RA

890F

1478

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8S

pdt

Fast

Res

pons

e S

afe

Sta

rt C

heck

1486

RA

890F

1338

RM

7890

A10

31R

7847

A10

2512

050

/60

300.

814

94R

A89

0F13

46R

M78

90A

1031

R78

47A

1033

120

50/6

030

315

02R

A89

0F12

70d

R

M78

90A

1015

R78

47A

1025

120

50/6

015

0.8

1510

RA

890F

1288

d

RM

7890

A10

15R

7847

A10

3312

050

/60

153

1528

RA

890F

1270

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8S

pdt

1536

NO

NE

e

EC

7890

A10

11R

7847

A10

2524

050

/60

150.

815

44R

A89

0F13

87e

E

C78

90A

1011

R78

47A

1033

240

50/6

015

315

51R

A89

0F13

38R

M78

90A

1031

R78

47A

1025

120

50/6

030

0.8

Spd

t15

69R

A89

0F13

46R

M78

90A

1031

R78

47A

1033

120

50/6

030

3S

pdt

1577

NO

NE

e

EC

7890

A10

11R

7847

A10

2524

050

/60

300.

8S

pdt

1585

NO

NE

e

EC

7890

A10

11R

7847

A10

3324

050

/60

303

Spd

t15

93N

ON

Ee

E

C78

90A

1011

R78

47A

1025

240

50/6

015

0.8

Spd

t16

01N

ON

Ee

E

C78

90A

1011

R78

47A

1025

240

50/6

030

0.8

1619

NO

NE

e

EC

7890

A10

11R

7847

A10

3324

050

/60

303

1627

RA

890F

1478

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8Fa

st R

espo

nse

Saf

e S

tart

Che

ck16

35N

ON

Ed

R

M78

90A

1015

R78

47A

1025

120

50/6

015

0.8

Spd

tTa

mpe

r Rei

stan

t Rel

ay C

over

1643

NO

NE

d

RM

7890

A10

15R

7847

A10

3312

050

/60

153

Tam

per R

eist

ant R

elay

Cov

er16

50N

ON

Ee

E

C78

90A

1011

R78

47A

1025

220

50/6

015

0.8

Spd

t15

sec

ond

Del

ayed

Pul

l in

1668

NO

NE

e

EC

7890

A10

11R

7847

A10

2522

050

/60

100.

8S

pdt

1676

NO

NE

d

RM

7890

A10

15R

7847

A10

2512

050

/60

150.

8S

pdt

App

rove

d -4

0F (-

40C

)16

84N

ON

Ed

R

M78

90A

1015

R78

47A

1025

120

50/6

010

0.8

Spd

t16

92R

A89

0F16

92e

E

C78

90A

1011

R78

47A

1025

220

50/6

015

0.8

Spd

tH

oney

wel

l - M

exic

o O

nly

1700

RA

890F

1700

RM

7890

A10

31R

7847

A10

2512

050

/60

300.

8S

pdt

Hon

eyw

ell -

Mex

ico

Onl

y17

18R

A89

0F17

18R

M78

90A

1031

R78

47A

1033

120

50/6

030

3S

pdt

Hon

eyw

ell -

Mex

ico

Onl

y

(con

tinue

d)

Page 9: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

7 95-6855—15

Honeywell Primary Control Cross Reference

FOO

TNO

TES

:a

E

C78

90 o

pera

ting

volta

ge is

187

Vac

to 2

64 V

ac 5

0/60

Hz

b

Sug

gest

ed R

epla

cem

ent D

evic

e ha

s a

10 S

econ

d S

afet

y S

witc

h Ti

me

c

Sel

ect W

iring

Sub

base

Q78

00A

1005

for P

anel

Mou

ntin

g - W

iring

con

vers

ion

requ

ired

Q78

00B

1003

for B

urne

r/Wal

l Mou

ntin

g - W

iring

con

vers

ion

requ

ired

Q78

00F1

004

- Mou

nts

to e

xist

ing

wiri

ng s

ubba

sed

A

ltern

ate

Rep

lace

men

t RM

7890

B10

14.

RM

7890

B h

as a

shu

tter o

utpu

t ter

min

al.

e

Alte

rnat

e R

epla

cem

ent E

C78

90B

1010

. E

C78

90B

has

a s

hutte

r out

put t

erm

inal

. A 2

40 to

120

10v

a m

inim

um

trans

form

er w

ill b

e ne

eded

if d

etec

tor s

yste

m c

hang

ed to

shu

tter t

ype

dete

ctor

.f

Fo

r Sen

sor L

eadw

ire ru

ns g

reat

er th

an 5

0fee

t sel

ect a

ppro

pria

te a

mpl

ifier

.R

7847

A10

75 fo

r 0.8

Fla

me

Failu

re R

espo

nse

R78

47A

1082

for 3

.0 F

lam

e Fa

ilure

Res

pons

eg

78

00 S

erie

s ha

s on

ly a

line

vol

tage

out

put a

larm

.h

R

M78

90A

1056

or R

M78

90B

1048

can

repl

ace

the

RM

7890

A10

15. T

erm

inal

s 3

and

20 w

ill n

eed

to b

e ju

mpe

d.

TAB

LE 3

—R

A89

0F C

RO

SS R

EFER

ENC

E

Dev

ice

to b

e R

epla

ced

R

A89

0F

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Cur

rent

R

A89

0F78

00 S

erie

s

b c

h

Am

plifi

er

fVo

ltage

(V

ac)

Freq

uenc

y

(Hz)

Safe

ty S

witc

h Ti

min

g (S

ecs)

FFR

T (s

ec)

Ala

rm

Con

tact

s

g

1726

RA

890F

1726

e

EC

7890

A10

11R

7847

A10

3324

050

/60

303

Spd

tH

oney

wel

l - M

exic

o O

nly

1734

Con

sult

Orig

inal

E

quip

men

t M

anuf

actu

rer

120

50/6

015

3S

pdt

Spe

cial

for N

orth

Am

eric

an M

anuf

actu

ring

(con

tinue

d)

Page 10: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 8

Honeywell Primary Control Cross ReferenceTA

BLE

4—

RA

890G

CR

OSS

REF

EREN

CE

Dev

ice

to b

e R

epla

ced

RA

890G

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Cur

rent

RA

890G

7800

Ser

ies

b c

d e

g

Am

plifi

er

Vo

ltage

(V

ac)

Freq

uenc

y

(Hz)

Safe

ty S

witc

h Ti

min

g (S

ecs)

FFR

T (s

ec)

Ala

rm C

onta

cts

f

1005

RA

890G

1229

d

RM

7890

A10

15R

7849

A10

1512

050

/60

150.

810

13R

A89

0G12

29d

R

M78

90A

1015

R78

49A

1015

120

50/6

015

0.8

Spd

t10

21N

one

e

EC

7890

A10

11R

7849

A10

1524

050

/60

150.

810

39R

A89

0G12

45e

E

C78

90A

1011

R78

49A

1015

220

50/6

015

0.8

Spd

t10

47R

A89

0G12

60d

R

M78

90A

1015

R78

49A

1023

120

50/6

015

310

54R

A89

0G12

60d

R

M78

90A

1015

R78

49A

1023

120

50/6

015

3S

pdt

1062

Non

ea

e E

C78

90A

1011

R78

49A

1023

208

50/6

015

3S

pdt

1070

RA

890G

1229

d

RM

7890

A10

15R

7849

A10

1512

050

/60

150.

810

88R

A89

0G12

29d

R

M78

90A

1015

R78

49A

1015

120

50/6

015

0.8

Spd

t10

96N

one

e

EC

7890

A10

11R

7849

A10

1524

050

/60

150.

811

04R

A89

0G12

45e

E

C78

90A

1011

R78

49A

1015

220

50/6

015

0.8

Spd

t11

12R

A89

0G12

60d

R

M78

90A

1015

R78

49A

1023

120

50/6

015

311

20R

A89

0G12

60d

R

M78

90A

1015

R78

49A

1023

120

50/6

015

3S

pdt

1138

Non

ea

e E

C78

90A

1011

R78

49A

1023

208

50/6

015

3S

pdt

1146

RA

890G

1286

e

EC

7890

A10

11R

7849

A10

2324

050

/60

153

Spd

t11

53R

A89

0G12

29d

R

M78

90A

1015

R78

49A

1015

120

50/6

015

0.8

1161

RA

890G

1229

d

RM

7890

A10

15R

7849

A10

1512

050

/60

150.

8S

pdt

1179

RA

890G

1260

d

RM

7890

A10

15R

7849

A10

2312

050

/60

153

1187

RA

890G

1260

d

RM

7890

A10

15R

7849

A10

2312

050

/60

153

Spd

t11

95N

one

e

EC

7890

A10

11R

7849

A10

1524

050

/60

150.

8S

pdt

1203

RA

890G

1302

e

EC

7890

A10

11R

7849

A10

2322

050

/60

153

Spd

t12

11N

one

d

RM

7890

A10

15R

7849

A10

1512

050

/60

150.

812

29R

A89

0G12

29d

R

M78

90A

1015

R78

49A

1015

120

50/6

015

0.8

Spd

t12

37N

one

e

EC

7890

A10

11R

7849

A10

1524

050

/60

150.

812

45R

A89

0G12

45e

E

C78

90A

1011

R78

49A

1015

220

50/6

015

0.8

Spd

t12

52N

one

d

RM

7890

A10

15R

7849

A10

2312

050

/60

153

1260

RA

890G

1260

d

RM

7890

A10

15R

7849

A10

2312

050

/60

153

Spd

t12

78N

one

a e

EC

7890

A10

11R

7849

A10

2320

850

/60

153

Spd

t12

86R

A89

0G12

86e

E

C78

90A

1011

R78

49A

1023

240

50/6

015

3S

pdt

1294

Non

ee

E

C78

90A

1011

R78

49A

1015

240

50/6

015

0.8

Spd

t13

02R

A89

0G13

02e

E

C78

90A

1011

R78

49A

1023

220

50/6

015

3S

pdt

Page 11: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

9 95-6855—15

Honeywell Primary Control Cross Reference

FOO

TNO

TES

:a

E

C78

90 o

pera

ting

volta

ge is

187

Vac

to 2

64 V

ac 5

0/60

Hz

b

Sug

gest

ed R

epla

cem

ent D

evic

e ha

s a

10 S

econ

d S

afet

y S

witc

h Ti

me

c

Sel

ect W

iring

Sub

base

Q

7800

A10

05 fo

r Pan

el M

ount

ing

- Wiri

ng c

onve

rsio

n re

quire

dQ

7800

B10

03 fo

r Bur

ner/W

all M

ount

ing

- Wiri

ng c

onve

rsio

n re

quire

dQ

7800

F100

4 - M

ount

s to

exi

stin

g w

iring

sub

base

d

Alte

rnat

e R

epla

cem

ent R

M78

90B

1014

. R

M78

90B

has

a s

hutte

r out

put t

erm

inal

.e

A

ltern

ate

Rep

lace

men

t EC

7890

B10

10.

EC

7890

B h

as a

shu

tter o

utpu

t ter

min

al. A

240

to 1

20 1

0va

min

imum

tra

nsfo

rmer

will

be

need

ed if

det

ecto

r sys

tem

cha

nged

to s

hutte

r typ

e de

tect

or.

f

7800

Ser

ies

has

only

a li

ne v

olta

ge o

utpu

t ala

rm.

g

RM

7890

A10

56 o

r RM

7890

B10

48 c

an re

plac

e R

M78

9A10

15. A

jum

per b

etw

een

term

inal

s 3

and

20 w

ill n

eed

to b

e ad

ded.

TAB

LE 4

—R

A89

0G C

RO

SS R

EFER

ENC

E

Dev

ice

to b

e R

epla

ced

RA

890G

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Cur

rent

RA

890G

7800

Ser

ies

b c

d e

g

Am

plifi

er

Vo

ltage

(V

ac)

Freq

uenc

y

(Hz)

Safe

ty S

witc

h Ti

min

g (S

ecs)

FFR

T (s

ec)

Ala

rm C

onta

cts

f

1310

Non

ed

R

M78

90A

1015

R78

49A

1015

120

50/6

015

0.8

Spd

tA

ppro

ved

for -

40F

(-40

C)

1328

RA

890G

1328

d

RM

7890

A10

15R

7849

A10

1512

050

/60

150.

8S

pdt

Hon

eyw

ell -

Mex

ico

Onl

y13

36R

A89

0G13

36d

R

M78

90A

1015

R78

49A

1023

120

50/6

015

3S

pdt

Hon

eyw

ell -

Mex

ico

Onl

y13

44R

A89

0G13

44C

onsu

lt O

rigin

al

Equ

ipm

ent M

anu-

fact

urer

120

50/6

015

3S

pdt

Spe

cial

for N

orth

Am

eric

an M

anu-

fact

urin

g

(con

tinue

d)

Page 12: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 10

Honeywell Primary Control Cross ReferenceTA

BLE

5—

RA

890H

,J,K

DYN

AM

IC S

ELF-

CH

ECK

CR

OSS

REF

EREN

CE

Dev

ice

to b

e

Rep

lace

dR

epla

cem

ent

Func

tion

of D

evic

e to

be

repl

aced

Com

men

ts

Cur

rent

RA

890

7800

Ser

ies

b

c

Am

plifi

er

fVo

ltage

(V

ac)

Freq

uenc

y

(Hz)

Safe

ty

Switc

h Ti

min

g (S

ecs)

FFR

T

(sec

)A

larm

C

onta

cts

g

RA

890H

For I

nter

mitt

ent P

ilot A

pplic

atio

ns w

ith A

mpl

i-Che

ck

1003

Non

ed

R

M78

90A

1015

R78

47B

1031

120

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1011

Non

ea

e E

C78

90A

1011

R78

47B

1031

208

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1029

Non

ee

E

C78

90A

1011

R78

47B

1031

240

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1037

Non

eN

one

100

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1045

Non

ee

E

C78

90A

1011

R78

47B

1031

220

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1052

Non

ed

R

M78

90A

1015

R78

47B

1031

120

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

RA

890J

For S

tand

ing

Pilo

t App

licat

ions

with

Am

pli-C

heck

1008

Non

ed

R

M78

90C

1005

R78

47B

1031

120

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1016

Non

ed

R

M78

90C

1005

R78

47B

1031

120

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1024

Non

eN

one

208

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1032

Non

eN

one

240

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

RA

890K

Sam

e as

RA

890H

but

with

out S

afe

Sta

rt C

heck

1006

Non

eN

one

120

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1024

Non

eN

one

208

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

1032

Non

eN

one

240

50/6

015

2.5

Sps

tTa

mpe

r Rei

stan

t Rel

ay C

over

FOO

TNO

TES

:a

E

C78

90 o

pera

ting

volta

ge is

187

Vac

to 2

64 V

ac 5

0/60

Hz

b

Sug

gest

ed R

epla

cem

ent D

evic

e ha

s a

10 S

econ

d S

afet

y S

witc

h Ti

me

c

Sel

ect W

iring

Sub

base

Q

7800

A10

05 fo

r Pan

el M

ount

ing

- Wiri

ng c

onve

rsio

n re

quire

dQ

7800

B10

03 fo

r Bur

ner/W

all M

ount

ing

- Wiri

ng c

onve

rsio

n re

quire

dQ

7800

F100

4 - M

ount

s to

exi

stin

g w

iring

sub

base

d

Alte

rnat

e R

epla

cem

ent R

M78

90B

1014

. R

M78

90B

has

a s

hutte

r out

put t

erm

inal

.e

A

ltern

ate

Rep

lace

men

t EC

7890

B10

10.

EC

7890

B h

as a

shu

tter o

utpu

t ter

min

al. A

240

to 1

20

10va

min

imum

tran

sfor

mer

will

be

need

ed if

det

ecto

r sys

tem

cha

nged

to s

hutte

r typ

e de

tect

or.

f

For S

enso

r Lea

dwire

runs

gre

ater

than

50f

eet s

elec

t app

ropr

iate

am

plifi

er.

R78

47B

1072

for 3

.0 F

lam

e Fa

ilure

Res

pons

e g

78

00 S

erie

s ha

s on

ly a

line

vol

tage

out

put a

larm

.

Page 13: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

11 95-6855—15

Honeywell Primary Control Cross Reference

TAB

LE 6

—R

485

PRIM

ARY

REL

AY C

RO

SS R

EFER

ENC

ED

evic

e to

be

Rep

lace

dR

epla

cem

ent

Func

tion

of D

evic

e to

be

repl

aced

Com

men

ts78

00 S

erie

sd

Am

plifi

erW

iring

Sub

-ba

seVo

ltage

(Va

c)Fr

eque

ncy

(Hz)

Solid

St

ate

FFR

T (s

ec)

Flam

e D

etec

tor T

ype

R48

5A10

01R

M78

85A

1015

R78

47A

1033

b Q

7800

B10

0312

050

/60

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CM

ount

ed o

n Q

270A

Bas

e

R48

5A10

19E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0324

050

/60

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CM

ount

ed o

n Q

270A

Bas

e

R48

5A10

27a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0320

850

/60

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CM

ount

ed o

n Q

270A

Bas

e

R48

5A10

35R

M78

85A

1015

R78

47A

1033

b Q

7800

B10

0312

050

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CIn

tern

atio

nal M

odel

R48

5A10

43R

M78

85A

1015

R78

47A

1025

b Q

7800

B10

0312

050

/60

No

0.8

Flam

e R

od, R

ectif

ying

Pho

toce

ll c

Inte

rnat

iona

l Mod

elR

485A

1050

EC

7885

A10

11R

7847

A10

25b

Q78

00B

1003

240

50N

o0.

8Fl

ame

Rod

, Rec

tifyi

ng P

hoto

cell

cIn

tern

atio

nal M

odel

R48

5A10

68R

M78

85A

1015

R78

47A

1033

b Q

7800

B10

0312

060

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CFu

ngus

Pro

of

R48

5A10

76E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0324

050

/60

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CFu

ngus

Pro

of

R48

5B10

00R

M78

85A

1015

R78

47A

1033

b Q

7800

B10

0312

050

/60

Yes

3.0

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CM

ount

ed o

n Q

270A

Bas

e

R48

5B10

18E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0324

050

/60

Yes

3.0

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CM

ount

ed o

n Q

270A

Bas

e

R48

5B10

26a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0320

850

/60

Yes

3.0

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CM

ount

ed o

n Q

270A

Bas

e

R48

5B10

34E

C78

85A

1011

R78

47A

1025

b Q

7800

B10

0324

050

/60

Yes

0.8

Flam

e R

od, R

ectif

ying

Pho

toce

ll c

Mou

nted

on

Q27

0A B

ase

R48

5B10

42R

M78

85A

1015

R78

47A

1025

b Q

7800

B10

0312

050

/60

Yes

0.8

Flam

e R

od, R

ectif

ying

Pho

toce

ll c

Mou

nted

on

Q27

0A B

ase

R48

5X10

05E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0324

050

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CIn

tern

atio

nal M

odel

R48

5X10

13a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0320

850

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CIn

tern

atio

nal M

odel

R48

5X10

21E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0322

050

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CIn

tern

atio

nal M

odel

R48

5X10

39R

M78

85A

1015

R78

47A

1033

b Q

7800

B10

0312

050

No

2-4

Flam

e R

od, R

ectif

ying

Pho

toce

ll,

c

C70

12A

, CIn

tern

atio

nal M

odel

R48

5X10

47E

C78

85A

1011

R78

47A

1025

b Q

7800

B10

0322

050

No

0.8

Flam

e R

od, R

ectif

ying

Pho

toce

ll c

Inte

rnat

iona

l Mod

elR

485X

1054

EC

7885

A10

11R

7847

A10

33b

Q78

00B

1003

220

50/6

0Ye

s3.

0Fl

ame

Rod

, Rec

tifyi

ng P

hoto

cell,

c

C

7012

A, C

Mou

nted

on

Q27

0A B

ase

R48

5X10

62E

C78

85A

1011

R78

47A

1025

b Q

7800

B10

0322

050

/60

Yes

0.8

Flam

e R

od, R

ectif

ying

Pho

toce

ll c

Mou

nted

on

Q27

0A B

ase

FOO

TNO

TES

:a

R

epla

cem

ent E

C78

85 o

pera

ting

volta

ge is

187

Vac

to 2

64 V

ac, 5

0/60

Hz

b

Use

Q78

00A

1005

for P

anel

Mou

nt A

pplic

atio

nsc

If

Rec

tifyi

ng P

hoto

cell

need

s re

plac

emen

t - s

ee C

7962

with

app

ropr

iate

R78

51B

am

plifi

erd

S

ugge

sted

repl

acem

ent i

s a

sem

i-aut

omat

ic fu

nctio

ning

dev

ice.

If R

485

was

ope

rate

d au

tom

atic

ally

sel

ect a

sim

ilar f

unct

ioni

ng R

M/E

C li

ke a

RM

7890

for e

xam

ple.

Page 14: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 12

Honeywell Primary Control Cross ReferenceTA

BLE

7—

R40

75 C

RO

SS R

EFER

ENC

ED

evic

e to

be

Rep

lace

dR

epla

cem

ent d

Func

tion

of D

evic

e to

be

repl

aced

Com

men

ts12

0 Va

c

78

00 S

erie

s20

8/22

0/24

0

Va

c a

7800

Ser

ies

Am

plifi

erW

iring

Sub

-ba

seVo

ltage

(V

ac)

Freq

uen-

cy (

Hz)

Solid

St

ate

FFR

T (s

ec)

Term

inal

M

onito

r 2k

Rel

ay

Volta

ge

Con

tinuo

us

Pilo

t App

l. C

ircui

t Pr

ovid

ed

Flam

e D

etec

tor

Type

R40

75A

1009

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0312

0/20

8/24

050

/60

No

2-4

Yes

No

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

With

Q44

2A fl

ush

mou

nt c

abin

et, w

ith

Q29

4 su

rface

mou

nt

cabi

net w

ith Q

295

Mou

ntin

g P

late

R40

75A

1017

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0312

0/20

8/24

050

/60

No

2-4

Yes

No

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

With

Q44

2A fl

ush

mou

nt c

abin

et, w

ith

Q29

4 su

rface

mou

nt

cabi

net w

ith Q

295

Mou

ntin

g P

late

R40

75A

1025

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1025

b Q

7800

B10

0312

0/20

8/24

050

/60

No

2-4

Yes

No

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

With

Q44

2A fl

ush

mou

nt c

abin

et, w

ith

Q29

4 su

rface

mou

nt

cabi

net w

ith Q

295

Mou

ntin

g P

late

R40

75A

1033

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1025

b Q

7800

B10

0312

0/20

8/24

050

/60

No

2-4

Yes

No

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

With

Q44

2A fl

ush

mou

nt c

abin

et, w

ith

Q29

4 su

rface

mou

nt

cabi

net w

ith Q

295

Mou

ntin

g P

late

R40

75A

1041

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0312

0/20

8/24

050

No

2-4

Yes

No

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

With

Qrr

eA fl

ush

mou

nt c

abin

et

R40

75A

1058

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0312

0/20

8/24

050

No

2-4

Yes

No

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

With

Qrr

eA fl

ush

mou

nt c

abin

et

R40

75B

1007

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0312

0/20

8/24

050

/60

No

2-4

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

R40

75B

1015

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0312

0/20

8/24

050

/60

No

2-4

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

R40

75B

1023

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1033

b Q

7800

B10

0311

0/22

050

No

2-4

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

R40

75B

1031

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1025

b Q

7800

B10

0312

0/20

8/24

050

/60

No

2-4

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

R40

75B

1049

RM

7885

A10

15a

E

C78

85A

1011

R78

47A

1025

b Q

7800

B10

0311

0/22

050

No

2-4

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

A, C

Page 15: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

13 95-6855—15

Honeywell Primary Control Cross Reference

FOO

TNO

TES

:a

R

epla

cem

ent E

C78

85 o

pera

ting

volta

ge is

198

Vac

to 2

64 V

ac, 5

0/60

H

b

Use

Q78

00A

1005

for P

anel

Mou

nt A

pplic

atio

nsc

If

Rec

tifyi

ng P

hoto

cell

need

s re

plac

emen

t - s

ee C

7962

with

app

ropr

iate

am

plifi

er

d

Sug

gest

ed re

plac

emen

t is

a se

mi-a

utom

atic

func

tioni

ng d

evic

e. I

f the

R40

75 w

as o

pera

ted

auto

mat

ical

ly s

elec

t a s

imila

r fun

ctio

ning

RM

/EC

like

a R

M78

90 fo

r exa

mpl

e.

TAB

LE 7

—R

4075

CR

OSS

REF

EREN

CE

Dev

ice

to b

e R

epla

ced

Rep

lace

men

t dFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

120

Vac

7800

Ser

ies

208/

220/

240

Vac

a

78

00 S

erie

s

Am

plifi

erW

iring

Sub

-ba

seVo

ltage

(V

ac)

Freq

uen-

cy (

Hz)

Solid

St

ate

FFR

T (s

ec)

Term

inal

M

onito

r 2k

Rel

ay

Volta

ge

Con

tinuo

us

Pilo

t App

l. C

ircui

t Pr

ovid

ed

Flam

e D

etec

tor

Type

R40

75B

1056

RM

7885

A10

15R

7847

A10

33b

Q78

00B

1003

120

50/6

0N

o2-

4N

oYe

sFl

ame

Rod

, Rec

-tif

ying

Pho

toce

ll,

c

C70

12A

, CR

4075

C10

05R

M78

85A

1015

Sel

ect P

rope

r A

mpl

ifier

b Q

7800

B10

0312

050

/60

Yes

See

A

mp

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

R40

75C

1013

a

EC

7885

A10

11S

elec

t Pro

per

Am

plifi

erb

Q78

00B

1003

208

50/6

0Ye

sS

ee

Am

pN

oYe

sFl

ame

Rod

, Rec

-tif

ying

Pho

toce

ll,

c

C70

12R

4075

C10

21a

E

C78

85A

1011

Sel

ect P

rope

r A

mpl

ifier

b Q

7800

B10

0322

050

Yes

See

A

mp

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

R40

75C

1039

a

EC

7885

A10

11S

elec

t Pro

per

Am

plifi

erb

Q78

00B

1003

240

50/6

0Ye

sS

ee

Am

pN

oYe

sFl

ame

Rod

, Rec

-tif

ying

Pho

toce

ll,

c

C70

12R

4075

D10

03R

M78

85A

1015

Sel

ect P

rope

r A

mpl

ifier

b Q

7800

B10

0312

050

/60

Yes

See

A

mp

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

R40

75E

1000

RM

7885

A10

15S

elec

t Pro

per

Am

plifi

erb

Q78

00B

1003

120

50/6

0Ye

sS

ee

Am

pN

oYe

sFl

ame

Rod

, Rec

-tif

ying

Pho

toce

ll,

c

C70

12

Dua

l Sys

tem

dev

ice,

w

ill re

quire

d 2

RM

7885

sys

tem

s.R

4075

E10

18a

E

C78

85A

1011

Sel

ect P

rope

r A

mpl

ifier

b Q

7800

B10

0322

050

Yes

See

A

mp

No

Yes

Flam

e R

od, R

ec-

tifyi

ng P

hoto

cell,

c

C

7012

Dua

l Sys

tem

dev

ice,

w

ill re

quire

d 2

EC

7885

sys

tem

s.

(con

tinue

d)

Page 16: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 14

Honeywell Primary Control Cross ReferenceTA

BLE

8—

HO

NEY

WEL

L R

4138

CR

OSS

REF

EREN

CE

Dev

ice

to b

e R

epla

ced

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

Func

tiona

l 780

0 Se

ries

a c

d

Purg

e Ti

mer

e

Am

plifi

er

fVo

ltage

(Vac

)Fr

eque

ncy

(Hz)

Safe

ty S

witc

h Ti

min

g (S

ecs)

Purg

e Ti

min

gA

mpl

ifier

1 se

cond

Po

wer

Fa

ilure

O

verr

ide

R41

38A

1004

b

R

M78

38A

1014

Sel

ecta

ble

Sel

ecta

ble

120/

208/

240

50/6

015

Sel

ecta

ble

Flam

e R

od o

r C

7012

E, F

R41

38A

1001

2b

RM

7838

A10

14S

elec

tabl

eS

elec

tabl

e12

0/20

8/24

050

/60

15S

elec

tabl

eFl

ame

Rod

or

C70

12E

, FR

4138

A10

20R

M78

38A

1014

Sel

ecta

ble

Sel

ecta

ble

120

50/6

015

Sel

ecta

ble

Flam

e R

od o

r C

7012

E, F

R41

38A

1038

RM

7838

A10

14S

elec

tabl

eS

elec

tabl

e12

050

/60

15S

elec

tabl

eFl

ame

Rod

or

C70

12E

, F

R41

38B

1002

b g

R

M78

38A

1014

Sel

ecta

ble

Sel

ecta

ble

120/

208/

240

50/6

015

Sel

ecta

ble

Flam

e R

od o

r C

7012

E, F

Yes

R41

38B

1010

b g

R

M78

38A

1014

Sel

ecta

ble

Sel

ecta

ble

120/

208/

240

50/6

030

Sel

ecta

ble

Flam

e R

od o

r C

7012

E, F

Yes

R41

38B

1028

RM

7838

A10

14 g

Sel

ecta

ble

Sel

ecta

ble

120

50/6

015

Sel

ecta

ble

Flam

e R

od o

r C

7012

E, F

Yes

R41

38C

1000

Non

eS

elec

tabl

eS

elec

tabl

e10

050

/60

15S

elec

tabl

eS

elec

tabl

eN

eon

Ligh

ts; N

ever

P

rodu

ced

R41

38C

1018

RM

7838

A10

14 f

Sel

ecta

ble

Sel

ecta

ble

120

50/6

015

Sel

ecta

ble

Sel

ecta

ble

Inca

ndes

cent

Lig

hts

R41

38C

1026

f h

Sel

ecta

ble

Sel

ecta

ble

240

50/6

015

Sel

ecta

ble

Sel

ecta

ble

Inca

ndes

cent

Lig

hts

R41

38C

1034

f h

S

elec

tabl

eS

elec

tabl

e22

050

15S

elec

tabl

eS

elec

tabl

eIn

cand

esce

nt L

ight

s

R41

38D

1008

Non

eS

elec

tabl

eS

elec

tabl

e12

050

/60

15S

elec

tabl

eS

elec

tabl

eYe

sN

eon

Ligh

ts; N

ever

P

rodu

ced

R41

38D

1016

RM

7838

A10

14 f

gS

elec

tabl

eS

elec

tabl

e12

050

/60

15S

elec

tabl

eS

elec

tabl

eYe

sIn

cand

esce

nt L

ight

s

R41

38X

1001

b

R

M78

38A

1014

Sel

ecta

ble

Sel

ecta

ble

120/

200/

230

5015

Sel

ecta

ble

Flam

e R

od o

r C

7012

E, F

Page 17: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

15 95-6855—15

Honeywell Primary Control Cross Reference

Foot

note

s fo

r TA

BLE

8—

HO

NEY

WEL

L R

4138

CR

OSS

REF

EREN

CE

a

Sug

gest

ed R

epla

cem

ent i

s a

Sem

i-Aut

omat

ic fu

nctio

ning

dev

ice.

If R

4138

was

ope

rate

d au

tom

atic

ally

sel

ect a

sim

ilar f

unct

ioni

ng R

M li

ke a

RM

7895

for e

xam

ple.

b

Rep

lace

men

t Dev

ice

for 1

20 V

ac 5

0/60

Hz

App

licat

ions

Onl

y - R

econ

trol i

f vol

tage

opt

ion

NO

T 12

0 Va

cc

S

ugge

sted

Rep

lace

men

t Dev

ice

has

a 10

Sec

ond

Saf

ety

Sw

itch

Tim

ed

S

elec

t Wiri

ng S

ubba

se

Q78

00A

1005

for P

anel

Mou

ntin

g - W

iring

con

vers

ion

requ

ired

Q78

00B

1003

for B

urne

r/Wal

l Mou

ntin

g - W

iring

con

vers

ion

requ

ired

e

Pur

ge T

imer

Opt

ions

- C

heck

tim

ing

of in

stal

led

S42

7 an

d se

lect

app

ropr

iate

Pug

e Ti

mer

. N

OTE

: A

purg

e tim

er M

US

T be

inst

alle

d in

repl

acem

ent R

elay

Mod

ule

Tim

ing

ST78

00Ti

min

gST

7800

2 se

cond

sA

1005

2.5

Min

ute

A10

70

7 se

cond

sA

1013

4 M

inut

eA

1088

10 s

econ

dsA

1021

6 M

inut

eA

1096

30 s

econ

dsA

1039

9 M

inut

eA

1104

40 s

econ

dsA

1047

12 M

inut

eA

1112

60 s

econ

dsA

1054

15 M

inut

eA

1120

90 s

econ

dsA

1062

22 M

inut

eA

1138

30 M

inut

eA

1146

f

Am

plifi

er O

ptio

ns

Rec

tific

atio

nSt

anda

rd>5

0 fe

et le

ad-

wire

run

Am

pli-c

heck

>50

feet

lead

-w

ire ru

n0.

8 se

c. F

FRT

R78

47A

1025

R78

47A

1075

R78

47B

1023

R78

47B

1064

3 se

c. F

FRT

R78

47A

1033

R78

47A

1082

R78

47B

1031

R78

47B

1072

UV 0.8

sec.

FFR

TR

7849

A10

15R

7849

B10

13

3 se

c. F

FRT

R78

49A

1023

R78

49B

1021

Dyn

amic

Sel

f-Che

ck fo

r Det

ecto

r

C70

12E

, FR

7847

C10

05

C70

61A

, FR

7861

A10

263

sec.

FFR

T

R78

61A

1034

0.8

sec.

FFR

T

C70

76A

, DR

7886

A10

01

g

Rep

lace

men

t RM

7838

DO

ES

NO

T ha

ve p

rovi

sion

s fo

r 1 s

econ

d P

ower

Fai

lure

Ove

rdrid

eh

R

econ

trol s

yste

m to

120

Vac.

Page 18: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 16

Honeywell Primary Control Cross ReferenceTA

BLE

9—

HO

NEY

WEL

L R

4795

CR

OSS

REF

EREN

CE

Dev

ice

to b

e R

epla

ced

Cur

rent

e f

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

7800

Ser

ies

Volta

ge

(Vac

)Fr

e-qu

ency

(H

z)

Safe

ty

Switc

h Ti

min

g (S

ecs)

Purg

e Ti

m-

ing

Am

plifi

erA

larm

C

on-

tact

s78

00 S

erie

s

b c

g h

iPu

rge

Tim

er

eA

mpl

ifier

f

R47

95A

1008

R47

95A

1016

RM

7895

A10

14S

elec

tabl

eS

elec

tabl

e12

050

/60

15S

elec

tabl

eS

elec

tabl

eR

4795

A10

16R

4795

A10

16R

M78

95A

1014

Sel

ecta

ble

Sel

ecta

ble

120

50/6

015

Sel

ecta

ble

Sel

ecta

ble

Spd

tR

4795

A10

24R

4795

A10

16R

M78

95A

1014

ST7

800A

1039

R78

47A

1033

120

50/6

015

ST7

1A10

18R

7289

A10

04R

4795

A10

32R

4795

A10

16R

M78

95A

1014

ST7

800A

1039

R78

47A

1033

120

50/6

015

ST7

1A10

18R

7289

A10

04S

pdt

R47

95A

1040

Non

eE

C78

95A

1010

Sel

ecta

ble

Sel

ecta

ble

220

50/6

015

Sel

ecta

ble

Sel

ecta

ble

Spd

tR

4795

A10

57N

one

EC

7895

A10

10S

elec

tabl

eS

elec

tabl

e24

050

/60

15S

elec

tabl

eS

elec

tabl

eS

pdt

R47

95A

1065

R47

95A

1016

RM

7895

A10

14S

T780

0A10

54R

7847

A10

3312

050

/60

15S

T71A

1026

R72

89A

1004

R47

95A

1073

R47

95A

1016

RM

7895

A10

14S

T780

0A10

54R

7847

A10

3312

050

/60

15S

elec

tabl

eR

7289

A10

04S

pdt

R47

95A

1081

R47

95A

1016

RM

7895

A10

14S

elec

tabl

eS

elec

tabl

e12

060

15S

elec

tabl

eS

elec

tabl

eS

pdt

-40F

(-40

C) r

ated

use

with

R72

89A

1020

(Rec

tifi-

catio

n or

R72

90A

1027

(UV

) Am

plifi

ers

R47

95A

1099

Non

eN

one

100

50/6

015

Sel

ecta

ble

Sel

ecta

ble

Spd

tR

4795

A11

07N

one

a

EC

7895

A10

10S

elec

tabl

eS

elec

tabl

e20

050

/60

15S

elec

tabl

eS

elec

tabl

eS

pdt

R47

95C

1004

RM

7895

A10

14S

elec

tabl

eS

elec

tabl

e12

050

/60

15S

T71A

1018

Sel

ecta

ble

Con

tinuo

us P

ilot A

pplic

atio

ns.

Use

Q26

7A s

ub-

base

R47

95D

1002

Non

eR

M78

95A

1014

Sel

ecta

ble

Sel

ecta

ble

120

50/6

015

Sel

ecta

ble

Sel

ecta

ble

Spd

tR

4795

D10

10N

one

RM

7895

A10

14S

elec

tabl

eS

elec

tabl

e12

050

/60

15S

elec

tabl

eS

elec

tabl

eR

4795

D10

28N

one

EC

7895

A10

10S

elec

tabl

eS

elec

tabl

e22

050

/60

15S

elec

tabl

eS

elec

tabl

eS

pdt

R47

95D

1036

Non

eE

C78

95A

1010

Sel

ecta

ble

Sel

ecta

ble

240

50/6

015

Sel

ecta

ble

Sel

ecta

ble

Spd

tR

4795

D10

44N

one

Non

e10

050

/60

15S

elec

tabl

eS

elec

tabl

eS

pdt

R47

95D

1051

Non

eR

M78

95A

1014

Sel

ecta

ble

Sel

ecta

ble

120

6015

Sel

ecta

ble

Sel

ecta

ble

Spd

t-4

0F (-

40C

) rat

ed u

se w

ith R

7289

A10

20 (R

ectifi

-ca

tion

or R

7290

A10

27 (U

V) A

mpl

ifier

sR

4795

D10

69N

one

a

EC

7895

A10

10S

elec

tabl

eS

elec

tabl

e20

050

/60

15S

elec

tabl

eS

elec

tabl

eS

pdt

Page 19: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

17 95-6855—15

Honeywell Primary Control Cross Reference

Foot

note

s fo

r TA

BLE

9—

HO

NEY

WEL

L R

4795

CR

OSS

REF

EREN

CE

a

EC

7895

ope

ratin

g vo

ltage

is 1

87 V

ac to

264

Vac

50/

60 H

zb

S

ugge

sted

Rep

lace

men

t Dev

ice

has

a 10

Sec

ond

Saf

ety

Sw

itch

Tim

ec

S

elec

t Wiri

ng S

ubba

seQ

7800

A10

05 fo

r Pan

el M

ount

ing

- Wiri

ng c

onve

rsio

n re

quire

dQ

7800

B10

03 fo

r Bur

ner/W

all M

ount

ing

- Wiri

ng c

onve

rsio

n re

quire

dQ

7800

F101

2 - M

ount

s to

exi

stin

g w

iring

sub

base

e

Pur

ge T

imer

Opt

ions

R47

95 w

/ ST7

178

00 S

erie

s w

/ ST7

800

7A

1000

A10

13

10A

1042

A10

21

30A

1018

A10

39

60A

1026

A10

54

90A

1034

A10

62

f

Am

plifi

er O

ptio

ns

R47

95 w

/78

00 S

erie

s w

/R

ectifi

catio

n

0.8

R72

89A

1012

g R

7847

A10

25

3R

7289

A10

04g

R78

47A

1033

3 ra

ted

for -

40R

7289

A10

20g

R78

47A

1033

UV

0.8

R72

90A

1019

R78

49A

1015

3R

7290

A10

01R

7849

A10

23

3 ra

ted

for -

40R

7290

A10

27R

7849

A10

23

g

For S

enso

r Lea

dwire

runs

gre

ater

than

50f

eet s

elec

t app

ropr

iate

am

plifi

er.

R78

47A

1075

for 0

.8 F

lam

e Fa

ilure

Res

pons

eR

7847

A10

82 fo

r 3.0

Fla

me

Failu

re R

espo

nse

h

Rep

lace

men

t Dev

ices

hav

e on

ly a

line

vol

tage

out

put a

larm

.i

R

M78

97A

1002

can

be

used

in p

lace

of R

M78

95A

1014

. A ju

mpe

r bet

wee

n te

rmin

als

5 an

d 20

will

nee

d to

be

adde

d.

Page 20: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 18

Honeywell Primary Control Cross ReferenceTA

BLE

10—

HO

NEY

WEL

L R

7023

CR

OSS

REF

EREN

CE

Dev

ice

to b

e R

epla

ced

Rep

lace

men

tFu

nctio

n of

Dev

ice

to b

e re

plac

edC

omm

ents

7800

Ser

ies

Am

plifi

erW

iring

Sub

base

Volta

ge

(Vac

)Fr

eque

ncy

(H

z)R

elay

Sw

itchi

ngSo

lid

Stat

eFF

RT

(s

ec)

Flam

e D

etec

tor T

ype

c

d

R70

23A

1005

RM

7823

A10

16R

7847

A10

33b

Q78

00B

1003

120

50/6

0(2

)spd

tno

2-4

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

Inte

rnat

iona

l Mod

el

R70

23A

1013

a

EC

7823

A10

04R

7847

A10

33b

Q78

00B

1003

208

50/6

0(2

)spd

tno

2-4

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

R70

23A

1021

EC

7823

A10

04R

7847

A10

33b

Q78

00B

1003

220

50(2

)spd

tno

2-4

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

R70

23A

1039

EC

7823

A10

04R

7847

A10

33b

Q78

00B

1003

240

50/6

0(2

)spd

tno

2-4

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

R70

23A

1047

RM

7823

A10

16R

7847

A10

25b

Q78

00B

1003

120

50/6

0(2

)spd

tno

0.8

Flam

e ro

d, re

ctify

ing

phot

ocel

lR

7023

A10

54a

E

C78

23A

1004

R78

47A

1025

b Q

7800

B10

0320

850

/60

(2)s

pdt

no0.

8Fl

ame

rod,

rect

ifyin

g ph

otoc

ell

R70

23A

1062

EC

7823

A10

04R

7847

A10

25b

Q78

00B

1003

220

50(2

)spd

tno

0.8

Flam

e ro

d, re

ctify

ing

phot

ocel

lR

7023

A10

70E

C78

23A

1004

R78

47A

1025

b Q

7800

B10

0324

050

/60

(2)s

pdt

no0.

8Fl

ame

rod,

rect

ifyin

g ph

otoc

ell

Inte

rnat

iona

l Mod

el

R70

23B

1003

RM

7823

A10

16R

7847

A10

33b

Q78

00B

1003

120

50/6

0(2

)spd

tye

s3

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

R70

23B

1011

EC

7823

A10

04R

7847

A10

33b

Q78

00B

1003

240

50/6

0(2

)spd

tye

s3

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

R70

23B

1029

a

EC

7823

A10

04R

7847

A10

33b

Q78

00B

1003

208

50/6

0(2

)spd

tye

s3

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

R70

23B

1037

EC

7823

A10

04R

7847

A10

25b

Q78

00B

1003

240

50/6

0(2

)spd

tye

s0.

8Fl

ame

rod,

rect

ifyin

g ph

otoc

ell

R70

23B

1045

RM

7823

A10

16R

7847

A10

25b

Q78

00B

1003

120

50/6

0(2

)spd

tye

s0.

8Fl

ame

rod,

rect

ifyin

g ph

otoc

ell

R70

23B

1052

EC

7823

A10

04R

7847

A10

33b

Q78

00B

1003

220

50/6

0(2

)spd

tye

s3

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

Inte

rnat

iona

l Mod

el

R70

23B

1060

EC

7823

A10

04R

7847

A10

25b

Q78

00B

1003

220

50/6

0(2

)spd

tye

s0.

8Fl

ame

rod,

rect

ifyin

g ph

otoc

ell

Inte

rnat

iona

l Mod

el

R70

23C

1001

RM

7823

A10

16R

7849

A10

23b

Q78

00B

1003

120

50/6

0(1

)spd

tye

s3

UV

- C

7027

, C70

35,

C70

44R

7023

C10

19R

M78

23A

1016

R78

49A

1015

b Q

7800

B10

0312

050

/60

(1)s

pdt

yes

0.8

UV

- C

7027

, C70

35,

C70

44R

7023

C10

27E

C78

23A

1004

R78

49A

1015

b Q

7800

B10

0322

050

/60

(1)s

pdt

yes

0.8

UV

- C

7027

, C70

35,

C70

44In

tern

atio

nal M

odel

R70

23C

1035

EC

7823

A10

04R

7849

A10

23b

Q78

00B

1003

220

50/6

0(1

)spd

tye

s3

UV

- C

7027

, C70

35,

C70

44In

tern

atio

nal M

odel

R70

23C

1043

EC

7823

A10

04R

7849

A10

23b

Q78

00B

1003

240

50/6

0(1

)spd

tye

s3

UV

- C

7027

, C70

35,

C70

44R

7023

C10

50E

C78

23A

1004

R78

49A

1015

b Q

7800

B10

0324

050

/60

(1)s

pdt

yes

0.8

UV

- C

7027

, C70

35,

C70

44R

7023

C10

68R

M78

23A

1016

R78

49A

1023

b Q

7800

B10

0312

060

(1)s

pdt

yes

3U

V -

C70

27, C

7035

, C

7044

-40F

(-40

C) R

ated

Page 21: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

19 95-6855—15

Honeywell Primary Control Cross Reference

FOO

TNO

TES

:a

E

C78

23 o

pera

ting

volta

ge is

187

Vac

to 2

64 V

ac 5

0/60

Hz

b

Use

Q78

00A

1005

for P

anel

Mou

nt a

pplic

atio

ns.

c

Rep

lace

rect

ifyin

g P

hoto

cell

with

C79

62B

det

ecto

r and

app

ropr

iate

R78

51B

Am

plifi

erd

S

hutte

r typ

e de

tect

ors

can

be u

sed

with

the

EC

/RM

7823

Fla

me

Sw

itche

s - S

elec

t app

ropr

iate

am

plifi

er.

TAB

LE 1

0—H

ON

EYW

ELL

R70

23 C

RO

SS R

EFER

ENC

ED

evic

e to

be

Rep

lace

dR

epla

cem

ent

Func

tion

of D

evic

e to

be

repl

aced

Com

men

ts78

00 S

erie

sA

mpl

ifier

Wiri

ng S

ubba

seVo

ltage

(V

ac)

Freq

uenc

y

(Hz)

Rel

ay

Switc

hing

Solid

St

ate

FFR

T

(sec

)Fl

ame

Det

ecto

r Typ

e c

d

R70

23X

1002

Non

e12

025

(2)s

pdt

no2-

4Fl

ame

rod,

rect

ifyin

g ph

otoc

ell

-40F

(-40

C) R

ated

R70

23X

1010

Non

e24

025

(2)s

pdt

no2-

4Fl

ame

rod,

rect

ifyin

g ph

otoc

ell,

C70

12A

, C-4

0F (-

40C

) Rat

ed

R70

23X

1028

EC

7823

A10

04R

7847

A10

33b

Q78

00B

1003

220

50(2

)spd

tno

2-4

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

Inte

rnat

iona

l Mod

el

R70

23X

1036

EC

7823

A10

04R

7847

A10

25b

Q78

00B

1003

220

50(2

)spd

tno

0.8

Flam

e ro

d, re

ctify

ing

phot

ocel

lIn

tern

atio

nal M

odel

R70

23X

1044

EC

7823

A10

04R

7847

A10

33b

Q78

00B

1003

220

50/6

0(2

)spd

tye

s3

Flam

e ro

d, re

ctify

ing

phot

ocel

l, C

7012

A, C

Inte

rnat

iona

l Mod

el

R70

23X

1051

EC

7823

A10

04R

7847

A10

25b

Q78

00B

1003

220

50/6

0(2

)spd

tye

s0.

8Fl

ame

rod,

rect

ifyin

g ph

otoc

ell

Inte

rnat

iona

l Mod

el

R70

23X

1069

EC

7823

A10

04R

7847

A10

25b

Q78

00B

1003

220

50/6

0(2

)spd

tno

0.8

Flam

e ro

d, re

ctify

ing

phot

ocel

lIn

tern

atio

nal M

odel

- Fu

ngus

P

roof

R70

23X

1077

R78

47A

1025

b Q

7800

B10

0310

050

/60

(2)s

pdt

yes

0.8

Flam

e ro

d, re

ctify

ing

phot

ocel

lIn

tern

atio

nal M

odel

R70

23X

1085

EC

7823

A10

04R

7847

A10

25b

Q78

00B

1003

220

50/6

0(2

)spd

tye

s0.

8Fl

ame

rod,

rect

ifyin

g ph

otoc

ell

Inte

rnat

iona

l Mod

el -

Fung

us

Pro

ofR

7023

X10

93E

C78

23A

1004

R78

49A

1015

b Q

7800

B10

0322

050

/60

(1)s

pdt

yes

0.8

UV

- C

7027

, C70

35,

C70

44In

tern

atio

nal M

odel

(con

tinue

d)

Page 22: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 20

Honeywell Primary Control Cross ReferenceTA

BLE

11—

HO

NEY

WEL

L R

7795

CR

OSS

-REF

EREN

CE

Dev

ice

to b

e R

epla

ced

Cur

rent

R

epla

cem

ent

c

7800

Ser

ies

Rep

lace

men

t a

b d

h i

FUN

CTI

ON

S O

F D

EVIC

E TO

BE

REP

LAC

EDC

omm

ents

Pre

purg

e Ti

min

g

Flam

e D

etec

tor

Type

b

FFR

TA

ir-Fl

ow

SW

Che

ck

Run

/Te

st

Switc

h

Safe

ty

Switc

h Ti

min

g (S

ec)

g

PFEP

INTM

Pi

lot

INTR

Pi

lot

MFE

PD

e-la

yed

M

V

Volt-

age

(V

ac)

Freq

uen-

cy (

Hz)

R77

95A

1001

R77

95A

1001

RM

7895

A10

14se

lect

able

UV

310

4, 1

0X

120

50/6

0

R77

95A

1019

Not

Pro

duce

d12

050

/60

R77

95A

1027

Con

sult

Orig

inal

E

quip

men

t M

anuf

actu

rer

UV

310

4, 1

0X

120

50/6

0P

ropr

ieta

ry

to F

ulto

n B

oile

r

R77

95B

1009

R77

95B

1009

RM

7895

A10

14se

lect

able

Rec

t3

104,

10

X12

050

/60

R77

95B

1017

e

R77

95B

1009

f

RM

7895

A10

14se

lect

able

Rec

t3

104,

10

X12

050

/60

With

Rem

ote

Res

et C

over

R77

95B

1025

Con

sult

Orig

inal

E

quip

men

t M

anuf

actu

rer

Rec

t3

104,

10

X12

050

/60

Pro

prie

tary

to

Ful

ton

Boi

ler

R77

95C

1007

R77

95C

1007

RM

7895

C10

12se

lect

able

UV

3X

104,

10

X10

X12

050

/60

R77

95C

1015

Con

sult

Orig

inal

E

quip

men

t M

anuf

actu

rer

UV

3X

104,

10

X10

X12

050

/60

Pro

prie

tary

to

Cle

aver

B

rook

s.

R77

95D

1005

R77

95D

1005

RM

7895

C10

12se

lect

able

Rec

t3

X10

4, 1

0X

10X

120

50/6

0

R77

95E

1002

Non

eR

M78

95B

1013

sele

ctab

leU

V3

X10

4, 1

012

050

/60

R77

95F1

000

Non

eR

M78

95B

1013

sele

ctab

leR

ect

3X

104,

10

120

50/6

0

R77

95G

1008

Non

eR

M78

95D

1011

sele

ctab

leU

V3

XX

104,

10

X10

X12

050

/60

R77

95H

1006

Non

eR

M78

95D

1011

sele

ctab

leR

ect

3X

X10

4, 1

0X

10X

120

50/6

0

FOO

TNO

TES

:a

C

hoos

e W

iring

Sub

base

Q78

00A

1005

for P

anel

Mou

ntin

g or

Q78

00B

1003

for B

urne

r or W

all M

ount

ing

b

Cho

ose

Flam

e A

mpl

ifier

, R78

47A

1033

for R

ectif

icat

ion

or R

7849

A10

23 fo

r UV

c

Sel

ect p

rope

r ST7

95 fo

r R77

95 R

epla

cem

ent

d

Sel

ect p

rope

r ST7

800

for 7

800

Ser

ies

Rep

lace

men

te

O

rder

Res

et C

over

(par

t num

ber 1

9836

5B) s

eper

atel

y. (C

over

obs

olet

e)f

O

rder

S78

20A

1007

Res

et M

odul

e se

pera

tely.

g

Mec

hani

cal L

ocko

ut in

15

seco

nds

h

RM

7897

A10

02 c

an b

e us

ed in

pla

ce o

f RM

7895

A10

14. A

jum

per b

etw

een

term

inal

s 5

and

20 w

ill n

eed

to b

e ad

ded.

i

RM

7897

C10

00 c

an b

e us

ed in

pla

ce o

f RM

7895

C10

12. A

jum

per b

etw

een

term

inal

s 5

and

20 w

ill n

eed

to b

e ad

ded.

Page 23: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

21 95-6855—15

Honeywell Primary Control Cross Reference

TAB

LE 1

2—78

00 S

ERIE

S C

RO

SS R

EFER

ENC

ED

evic

e to

be

Rep

lace

dC

urre

nt

Rep

lace

men

tA

ltern

ate

Rep

lace

men

tFl

ame

Am

plifi

er

a

Prep

urge

Volta

ge

(Vac

)Fr

e-qu

ency

(H

z)

Prei

gni-

tion

Run

/Te

st

Switc

h

PFEP

INTM

Pi

lot

INTR

Pi

lot

MFE

PD

elay

ed

MV

Shut

ter

Driv

e O

utpu

t

Post

purg

eC

omm

ents

Pre

purg

e Ti

min

gA

ir-flo

wA

ir-Fl

ow

Switc

h C

heck

CR

7890

B10

19C

R78

90B

1019

120

50/6

010

XIn

tegr

ated

shu

tter S

SU

V

dete

ctor

with

RM

7890

B10

14

Fuct

ion

usin

g a

Bra

d H

arris

on

type

3R

9006

A20

A12

0 9

pin

conn

ecto

r.

EC

7823

A10

04E

C78

23A

1004

Sel

ecta

ble

230

50/6

0X

Flam

e sw

itch

EC

7885

A10

03

EC

7885

A10

11S

elec

tabl

e 20

050

/60

4, 1

0X

XS

emi-A

utom

atic

com

bust

ion

cont

rol -

Spe

cial

for Y

amat

ake

EC

7885

A10

11E

C78

85A

1011

Sel

ecta

ble

230

50/6

04,

10

XX

Sem

i-Aut

omat

ic c

ombu

stio

n co

ntro

l

EC

7885

A10

29E

C78

85A

1011

Sel

ecta

ble

230

50/6

04,

10

XX

Sem

i-Aut

omat

ic c

ombu

stio

n co

ntro

l

EC

7890

A10

03

Non

eS

elec

tabl

e 20

050

/60

4, 1

0X

Spe

cial

for Y

amat

ake

EC

7890

A10

11

EC

7890

A10

11

EC

7890

B10

10S

elec

tabl

e 23

050

/60

4, 1

0X

0.8

or 3

.0 F

FRT

EC

7890

A10

29

EC

7890

A10

29

EC

7890

B10

28S

elec

tabl

e 23

050

/60

4, 1

0X

1.0

or 2

.0 F

FRT

EC

7890

A10

37

EC

7890

A10

37

Sel

ecta

ble

230

50/6

04,

10

XX

1.0

or 2

.0 F

FRT

and

Ear

ly

Spa

rk T

erm

inat

ion

EC

7890

B10

02

Non

eS

elec

tabl

e 20

050

/60

4, 1

0X

XS

peci

al fo

r Yam

atak

e

EC

7890

B10

10

EC

7890

B10

10

Sel

ecta

ble

230

50/6

04,

10

XX

0.8

or 3

.0 F

FRT

EC

7890

B10

28

EC

7890

B10

28

Sel

ecta

ble

230

50/6

04,

10

XX

1.0

or 2

.0 F

FRT

EC

7895

A10

02

Non

eS

elec

tabl

e b

Sel

ecta

ble

Pro

ven

200

50/6

04,

10

XX

Spe

cial

for Y

amat

ake

EC

7895

A10

10

EC

7895

A10

10

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n23

050

/60

4, 1

0X

X0.

8 or

3.0

FFR

T

EC

7895

A10

28

Non

eS

elec

tabl

e b

Sel

ecta

ble

Pro

ven

230

50/6

04,

10

XX

1.0

or 2

.0 F

FRT

EC

7895

C10

00

EC

7895

C10

00

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n23

050

/60

4, 1

0X

X0.

8 or

3.0

FFR

T

EC

7895

C10

18N

ot P

rodu

ced

EC

7895

C10

26N

one

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n23

050

/60

4, 1

0X

X1.

0 or

2.0

FFR

T

RM

7823

A10

08

RM

7823

A10

16

Sel

ecta

ble

120

50X

Flam

e sw

itch

RM

7823

A10

16

RM

7823

A10

16

Sel

ecta

ble

120

50/6

0X

Flam

e sw

itch

RM

7838

A10

06

RM

7838

A10

14

Sel

ecta

ble

b

S

elec

tabl

e 12

050

4, 1

0X

XS

emi-a

utom

atic

con

trol,

com

es

with

S78

00 D

ispl

ay

RM

7838

A10

14

RM

7838

A10

14

Sel

ecta

ble

b

S

elec

tabl

e 12

050

/60

4, 1

0X

XS

emi-a

utom

atic

con

trol,

com

es

with

S78

00 D

ispl

ay

RM

7838

B10

05R

M78

38B

1013

RM

7838

B10

21S

elec

tabl

e b

Sel

ecta

ble

Pro

ven

120

50X

X4,

10

XX

10X

Sem

i-Aut

omat

ic P

rogr

amm

er

cont

rol w

ith S

7800

Dis

play

M

odul

e, 4

wire

mod

ulat

ion,

LF

/HF

prov

ing

RM

7838

B10

13R

M78

38B

1013

RM

7838

B10

21S

elec

tabl

e b

Sel

ecta

ble

Pro

ven

120

50/6

0X

X4,

10

XX

10X

Sem

i-Aut

omat

ic P

rogr

amm

er

cont

rol w

ith S

7800

Dis

play

M

odul

e, 4

wire

mod

ulat

ion,

LF

/HF

prov

ing

RM

7838

B10

21R

M78

38B

1021

RM

7838

B10

21S

elec

tabl

e b

Sel

ecta

ble

Pro

ven

120

50/6

0X

X4,

10

XX

10X

Sem

i-Aut

omat

ic P

rogr

amm

er

cont

rol w

ith V

alve

Pro

ving

Fe

atur

e an

d P

rogr

am-

mab

le P

ost P

urge

, com

es w

ith

S78

00A

1142

Dis

play

Mod

ule,

4

wire

mod

ulat

ion,

LF/

HF

prov

ing.

With

blin

k co

de fa

ult

mes

sagi

ng.

RM

7838

C10

04R

M78

38C

1004

RM

7838

C10

12S

elec

tabl

e c

Sel

ecta

ble

Pro

ven

120

50/6

0X

X4,

10

XX

15X

Sem

i-Aut

omat

ic P

rogr

amm

er

cont

rol w

ith S

7800

Dis

play

M

odul

e, 4

wire

mod

ulat

ion,

LF/

HF

prov

ing.

Ala

rm S

ound

s on

ly

on s

afet

y sh

utdo

wn.

Req

uire

s S

T780

0C P

urge

Tim

er.

Page 24: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 22

Honeywell Primary Control Cross ReferenceTA

BLE

12—

7800

SER

IES

CR

OSS

REF

EREN

CE

Dev

ice

to b

e R

epla

ced

Cur

rent

R

epla

cem

ent

Alte

rnat

e R

epla

cem

ent

Flam

e A

mpl

ifier

a

Prep

urge

Volta

ge

(Vac

)Fr

e-qu

ency

(H

z)

Prei

gni-

tion

Run

/Te

st

Switc

h

PFEP

INTM

Pi

lot

INTR

Pi

lot

MFE

PD

elay

ed

MV

Shut

ter

Driv

e O

utpu

t

Post

purg

eC

omm

ents

Pre

purg

e Ti

min

gA

ir-flo

wA

ir-Fl

ow

Switc

h C

heck

RM

7838

C10

12R

M78

38C

1012

Sel

ecta

ble

c

S

elec

tabl

e P

rove

n12

050

/60

XX

4, 1

0X

X15

XS

emi-A

utom

atic

Pro

gram

mer

co

ntro

l with

Val

ve P

rovi

ng

Feat

ure

and

Pro

gram

-m

able

Pos

t Pur

ge, c

omes

with

S

7800

A11

42 D

ispl

ay M

odul

e,

4 w

ire m

odul

atio

n, L

F/H

F pr

ovin

g. A

larm

Sou

nds

only

on

saf

ety

shut

dow

n. R

equi

res

ST7

800C

Pur

ge T

imer

. With

bl

ink

code

faul

t mes

sagi

ng

RM

7838

C10

20R

M78

38C

1020

Sel

ecta

ble

c

S

elec

tabl

e P

rove

n12

050

/60

XX

4, 1

0X

X5

XS

emi-A

utom

atic

Pro

gram

-m

er c

ontro

l, co

mes

with

S

7800

A10

01 D

ispl

ay M

odul

e,

4 w

ire m

odul

atio

n, L

F/H

F pr

ovin

g. A

larm

Sou

nds

only

on

saf

ety

shut

dow

n. R

equi

res

ST7

800C

Pur

ge T

imer

. With

bl

ink

code

faul

t mes

sagi

ng.

Glo

bal A

ppro

val

RM

7885

A10

07

RM

7885

A10

15

Sel

ecta

ble

120

504,

10

XX

Sem

i-Aut

omat

ic c

ombu

stio

n co

ntro

l

RM

7885

A10

15

RM

7885

A10

15

Sel

ecta

ble

120

50/6

04,

10

XX

Sem

i-Aut

omat

ic c

ombu

stio

n co

ntro

l

RM

7885

A10

23

Non

eS

elec

tabl

e 10

050

/60

4, 1

0X

XS

emi-A

utom

atic

com

bust

ion

cont

rol -

Spe

cial

for Y

amat

ake

RM

7888

A10

01R

M78

88A

1019

Sel

ecta

ble

120

504

XP

LC S

eque

ncin

g pe

r Nor

th

Am

eric

an M

anuf

actu

ring

spec

ifica

tions

RM

7888

A10

19R

M78

88A

1019

Sel

ecta

ble

120

50/6

04

XP

LC S

eque

ncin

g pe

r Nor

th

Am

eric

an M

anuf

actu

ring

spec

ifica

tions

RM

7888

A10

27R

M78

88A

1027

Sel

ecta

ble

120

50/6

010

XP

LC S

eque

ncin

g pe

r Nor

th

Am

eric

an M

anuf

actu

ring

spec

ifica

tions

RM

7890

A10

07

RM

7890

A10

15

RM

7890

A10

56

Sel

ecta

ble

120

504,

10

X

RM

7890

A10

15

RM

7890

A10

15

RM

7890

A10

56

Sel

ecta

ble

120

50/6

04,

10

X

RM

7890

A10

31

RM

7890

A10

31

Sel

ecta

ble

120

50/6

0Fi

xed

30X

RM

7890

A10

49R

M78

90A

1049

Sel

ecta

ble

100

50/6

04,

10

XS

peci

al fo

r Yam

atak

e

RM

7890

A10

56

RM

7890

A10

56

RM

7890

B10

48

Sel

ecta

ble

120

50/6

0X

X4,

10

XX

XW

ith V

alve

Pro

ving

Fea

ture

an

d P

re Ig

nitio

n In

terlo

ck

Inpu

t. W

ith b

link

code

faul

t m

essa

ging

RM

7890

A10

64

RM

7890

A10

64

Sel

ecta

ble

120

50/6

0X

X4,

10

XX

XFu

ll P

FEP

with

Ear

ly S

park

Te

rmin

atio

n

RM

7890

B10

06

RM

7890

B10

14

RM

7890

B10

48

Sel

ecta

ble

120

504,

10

XX

RM

7890

B10

14

RM

7890

B10

14

RM

7890

B10

48

Sel

ecta

ble

120

50/6

04,

10

XX

RM

7890

B10

22

RM

7890

B10

22

Sel

ecta

ble

100

50/6

04,

10

XX

Spe

cial

for Y

amat

ake

RM

7890

B10

30

RM

7890

B10

30

Sel

ecta

ble

120

50/6

0fix

ed 1

0X

XA

larm

out

puts

mom

ent r

eset

pu

shed

per

Nor

th A

mer

ican

M

anuf

actu

ring

spec

ifica

tions

RM

7890

B10

48

RM

7890

B10

48

Sel

ecta

ble

120

50/6

0X

X4,

10

XX

XX

With

Val

ve P

rovi

ng F

eatu

re

and

Pre

Igni

tion

Inte

rlock

In

put.

With

blin

k co

de fa

ult

mes

sagi

ng

RM

7890

B10

55

RM

7890

B10

55

Sel

ecta

ble

120

50/6

04,

10

XX

Glo

bal A

ppro

val

RM

7890

C10

05

RM

7890

C10

05

Sel

ecta

ble

120

50/6

0X

for S

tand

ing

Pilo

t App

licat

ions

(con

tinue

d)

Page 25: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

23 95-6855—15

Honeywell Primary Control Cross Reference

TAB

LE 1

2—78

00 S

ERIE

S C

RO

SS R

EFER

ENC

ED

evic

e to

be

Rep

lace

dC

urre

nt

Rep

lace

men

tA

ltern

ate

Rep

lace

men

tFl

ame

Am

plifi

er

a

Prep

urge

Volta

ge

(Vac

)Fr

e-qu

ency

(H

z)

Prei

gni-

tion

Run

/Te

st

Switc

h

PFEP

INTM

Pi

lot

INTR

Pi

lot

MFE

PD

elay

ed

MV

Shut

ter

Driv

e O

utpu

t

Post

purg

eC

omm

ents

Pre

purg

e Ti

min

gA

ir-flo

wA

ir-Fl

ow

Switc

h C

heck

RM

7890

D10

04

RM

7890

D10

04

Sel

ecta

ble

120

50/6

015

/30

Xfo

r Inf

rare

d H

eate

r App

licat

ions

RM

7895

A10

06

RM

7895

A10

14R

M78

97A

1002

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n12

050

4, 1

0X

X

RM

7895

A10

14

RM

7895

A10

14

RM

7897

A10

02S

elec

tabl

e b

Sel

ecta

ble

Pro

ven

120

50/6

04,

10

XX

RM

7895

A10

22

Not

Pro

duce

d

RM

7895

A10

30

RM

7895

A10

30

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n12

050

/60

Lim

ited

XX

Req

uire

d Q

7800

A10

13 s

ub-

base

. Spe

cial

for F

ulto

n.

RM

7895

A10

48R

M78

95A

1048

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n12

050

/60

4, 1

0X

XS

park

shu

ts o

ff du

ring

PFE

P if

flam

e se

nsed

RM

7895

A10

55

RM

7895

A10

55

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n10

050

/60

4, 1

0X

X S

peci

al fo

r Yam

atak

e

RM

7895

A10

63

RM

7895

A10

63S

elec

tabl

e b

Sel

ecta

ble

Pro

ven

120

50/6

090

XX

RM

7895

B10

05

RM

7895

B10

13

Sel

ecta

ble

b

S

elec

tabl

e P

rove

nX

120

504,

10

XX

RM

7895

B10

13

RM

7895

B10

13

Sel

ecta

ble

b

S

elec

tabl

e P

rove

nX

120

50/6

04,

10

XX

RM

7895

C10

04

RM

7895

C10

12

RM

7897

C10

00S

elec

tabl

e b

Sel

ecta

ble

Pro

ven

120

50X

4, 1

0X

10X

X

RM

7895

C10

12

RM

7895

C10

12

RM

7897

C10

00S

elec

tabl

e b

Sel

ecta

ble

Pro

ven

120

50/6

0X

4, 1

0X

10X

X

RM

7895

C10

20R

M78

95C

1020

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n12

050

/60

X10

X10

XX

Spe

cial

Ear

ly S

park

Ter

min

a-tio

n

RM

7895

C10

38N

ot P

rodu

ced

RM

7895

C10

46N

ot P

rodu

ced

RM

7895

C10

53R

M78

95C

1053

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50/6

0X

3.0

fixed

X10

X

RM

7895

D10

03

RM

7895

D10

11

Sel

ecta

ble

b

S

elec

tabl

e P

rove

nX

120

50X

4, 1

0X

10X

X

RM

7895

D10

11

RM

7895

D10

11

Sel

ecta

ble

b

S

elec

tabl

e P

rove

nX

120

50/6

0X

4, 1

0X

10X

X

RM

7895

E10

02R

M78

95E

1002

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n12

050

/60

15, 3

0X

for I

nfra

red

Hea

ter A

pplic

atio

ns

RM

7895

E10

10R

M78

95E

1010

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n12

050

/60

15, 3

0X

AE

RC

O S

peci

al

RM

7895

F100

1R

M78

95F1

001

Sel

ecta

ble

b

S

elec

tabl

e P

rove

nX

120

50/6

015

, 30

Xfo

r Inf

rare

d H

eate

r App

licat

ions

RM

7896

A10

04

RM

7896

A10

12R

M78

97A

1002

Sel

ecta

ble

b

S

elec

tabl

e P

rove

n12

050

4, 1

0X

10X

15

RM

7896

A10

12R

M78

96A

1012

RM

7897

A10

02S

elec

tabl

e b

Sel

ecta

ble

Pro

ven

120

50/6

04,

10

X10

X15

RM

7896

B10

03

RM

7896

B10

11

Sel

ecta

ble

b

S

elec

tabl

e P

rove

nX

120

504,

10

X10

X15

RM

7896

B10

11

RM

7896

B10

11

Sel

ecta

ble

b

S

elec

tabl

e P

rove

nX

120

50/6

04,

10

X10

X15

RM

7896

C10

02R

M78

96C

1010

R

M78

97C

1000

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50X

4, 1

0X

10X

X15

RM

7896

C10

10

RM

7896

C10

10

RM

7897

C10

00S

elec

tabl

e b

S

elec

tabl

e P

rove

n12

050

/60

X4,

10

X10

XX

15

RM

7896

C10

28N

ot P

rodu

ced

RM

7896

C10

36R

M78

96C

1036

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50/6

0X

10X

10X

X15

Spe

cial

Ear

ly S

park

Ter

min

a-tio

n

RM

7896

D10

01

RM

7896

D10

19

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

X12

050

X4,

10

X10

XX

15

RM

7896

D10

19

RM

7896

D10

19

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

X12

050

/60

X4,

10

X10

XX

15

RM

7896

D10

27

RM

7896

D10

27

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

X12

050

/60

X4,

10

X10

XX

60W

ith b

link

code

Fau

lt M

essa

g-in

g, S

peci

al fo

r Bur

nham

RM

7897

A10

02R

M78

97A

1002

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50/6

0X

X

4, 1

0X

X10

XP

ro-

gram

med

With

Pre

Igni

tion

Inte

rlock

In

put a

nd b

link

code

Fau

lt M

essa

ging

. In

term

itten

t or I

n-te

rrup

ted

Pilo

t val

ve o

pera

tion

(con

tinue

d)

Page 26: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 24

Honeywell Primary Control Cross Reference

FOO

TNO

TES

:a

A

mpl

ifier

Opt

ions

Rec

tifica

tion

Stan

dard

>50

feet

lead

wire

run

Am

pli-c

heck

>50

feet

lead

wire

run

0.8

sec.

FFR

TR

7847

A10

25R

7847

A10

75R

7847

B10

23R

7847

B10

64

3 se

c. F

FRT

R78

47A

1033

R78

47A

1082

R78

47B

1031

R78

47B

1072

UV 0.8

sec.

FFR

TR

7849

A10

15R

7849

B10

13

3 se

c. F

FRT

R78

49A

1023

R78

49B

1021

Dyn

amic

Sel

f-Che

ck fo

r Det

ecto

r

C70

12E

, FR

7847

C10

05

C70

61A

, FR

7861

A10

263

sec.

FFR

T

R78

61A

1034

0.8

sec.

FFR

T

C70

76A

, DR

7886

A10

01

C79

61E

, FR

7851

C10

08

Opt

ical

C79

27, C

7962

0.8

sec.

FFR

TR

7851

B10

18

3 se

c. F

FRT

R78

51B

1000

c

Pur

ge T

imer

Opt

ions

Tim

ing

ST78

00Ti

min

gST

7800

2 se

cond

sC

1003

14 M

inut

eC

1078

20 s

econ

dsC

1011

16 M

inut

eC

1086

4 M

inut

eC

1029

18 M

inut

eC

1094

6 M

inut

eC

1037

20 M

inut

eC

1102

8 M

inut

eC

1045

22 M

inut

eC

1110

10 M

inut

eC

1052

24 M

inut

eC

1128

12 M

inut

eC

1060

30 M

inut

eC

1135

45 M

inut

eC

1143

Not

e: S

T780

0C p

urge

tim

ers

for u

se

with

RM

7838

C o

nly.

b

Pur

ge T

imer

Opt

ions

Tim

ing

ST78

00Ti

min

gST

7800

2 se

cond

sA

1005

2.5

Min

ute

A10

70

7 se

cond

sA

1013

4 M

inut

eA

1088

10 s

econ

dsA

1021

6 M

inut

eA

1096

30 s

econ

dsA

1039

9 M

inut

eA

1104

40 s

econ

dsA

1047

12 M

inut

eA

1112

60 s

econ

dsA

1054

15 M

inut

eA

1120

90 s

econ

dsA

1062

22 M

inut

eA

1138

30 M

inut

eA

1146

TAB

LE 1

2—78

00 S

ERIE

S C

RO

SS R

EFER

ENC

ED

evic

e to

be

Rep

lace

dC

urre

nt

Rep

lace

men

tA

ltern

ate

Rep

lace

men

tFl

ame

Am

plifi

er

a

Prep

urge

Volta

ge

(Vac

)Fr

e-qu

ency

(H

z)

Prei

gni-

tion

Run

/Te

st

Switc

h

PFEP

INTM

Pi

lot

INTR

Pi

lot

MFE

PD

elay

ed

MV

Shut

ter

Driv

e O

utpu

t

Post

purg

eC

omm

ents

Pre

purg

e Ti

min

gA

ir-flo

wA

ir-Fl

ow

Switc

h C

heck

RM

7897

C10

00R

M78

97C

1000

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50/6

0X

X

4, 1

0X

10X

XP

ro-

gram

med

With

Pre

Igni

tion

Inte

rlock

In

put a

nd b

link

code

faul

t mes

-sa

ging

. Int

erm

itten

t or I

nter

-ru

pted

Pilo

t val

ve o

pera

tion

RM

7897

C10

18R

M78

97C

1018

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50/6

0X

4,

10

XX

4X

Pro

-gr

amm

edW

ith p

re Ig

nitio

n In

terlo

ck In

put

and

blin

k co

de fa

ult m

essa

g-in

g. In

term

itten

t or I

nter

rupt

ed

pilo

t val

ve o

pera

tion

RM

7897

C10

27R

M78

97C

1027

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50/6

0X

4,

10

XX

10X

Pro

-gr

amm

edW

ith p

re Ig

nitio

n In

terlo

ck In

put

and

blin

k co

de fa

ult m

essa

g-in

g. In

term

itten

t or I

nter

rupt

ed

pilo

t val

ve o

pera

tion

- Spe

cial

JR

2 re

cycl

e fu

nctio

n on

loss

of

Mai

n Fl

ame.

-Spe

cial

per

Ti

tan

Aire

RM

7898

A10

02R

M78

98A

1002

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50/6

0X

X

4, 1

0X

10X

XP

ro-

gram

med

With

Val

ve P

rovi

ng F

eatu

re,

Pre

Igni

tion

Inte

rlock

Inpu

t and

bl

ink

code

faul

t mes

sagi

ng.

Inte

rmitt

ent o

r Int

erru

pted

Pilo

t va

lve

oper

atio

n

RM

7898

A10

18R

M78

98A

1018

Sel

ecta

ble

b

Sel

ecta

ble

Pro

ven

120

50/6

0X

X

4, 1

0X

10X

XP

ro-

gram

med

With

Val

ve P

rovi

ng F

eatu

re,

Pre

Igni

tion

Inte

rlock

Inpu

t and

bl

ink

code

faul

t mes

sagi

ng.

Inte

rmitt

ent o

r Int

erru

pted

Pilo

t va

lve

oper

atio

n an

d S

peci

al

Spa

rk S

huto

ff fe

atur

e.

(con

tinue

d)

Page 27: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

25 95-6855—15

Honeywell Primary Control Cross Reference

TFM

or U

VM re

plac

emen

tTF

M a

nd U

VM

ser

ies

devi

ces

cont

aine

d th

e Fl

ame

ampl

ifier

circ

uitry

on

the

devi

ce.

The

M2,

M3

and

M5

mod

els

incl

uded

plu

g in

(MTX

X) p

urge

func

tion.

N

ote

mod

el fo

r cor

rect

repl

acem

ent.

TAB

LE 1

3—H

ON

EYW

ELL

CR

OSS

-REF

EREN

CE

FOR

FIR

EYETM

TFM

AN

D U

VM R

EPLA

CEM

ENT

Dev

ice

to b

e R

epla

ced

RM

789X

/R71

20 R

epla

cem

ent

Volta

ge

(Vac

)Fr

e-qu

ency

(H

z)

Flam

e De

tete

ctor

Ty

pe

FFR

T (s

ec)

PFEP

(s

ec)

Pilo

t Ty

pe

(Int/I

tr)

a

Pre-

purg

e Ti

min

g

(Sec

)

Com

-m

ents

RM

7895

R

epla

cem

ent

b c

Enha

nced

R

M78

9X

Rep

lace

men

t b

c

R71

20

Rep

lace

-m

ent

c d

Purg

e Ti

mer

Am

plifi

erR

M78

9X/R

7120

Com

men

ts

TFM

1D

disc

ontin

ued

in 1

999

120

50/6

0R

ectifi

ca-

tion

0.8

10In

tR

elig

htR

M78

95A

1014

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

05R

7847

A10

25

TFM

1F

disc

ontin

ued

in 1

999

120

50/6

0R

ectifi

ca-

tion

410

Int

Rel

ight

RM

7895

A10

14R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

ST7

800A

1005

R78

47A

1033

TFM

-2A

712

050

/60

Rec

tifica

-tio

n2-

412

Int

7R

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

13R

7847

A10

33S

ee F

ootn

ote

e.

TFM

-2A

3012

050

/60

Rec

tifica

-tio

n2-

412

Int

30R

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

39R

7847

A10

33S

ee F

ootn

ote

e.

TFM

-2A

9012

050

/60

Rec

tifica

-tio

n2-

412

Int

90R

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

62R

7847

A10

33S

ee F

ootn

ote

e.

TFM

3-7

120

50/6

0R

ectifi

ca-

tion

2-4

12In

t7

Non

-re

cycl

eR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

13R

7847

A10

33S

ee F

ootn

ote

e.

TFM

3-3H

120

50/6

0R

ectifi

ca-

tion

2-4

12In

t7

Non

-re

cycl

eR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

13R

7847

A10

33S

ee F

ootn

ote

e.

TFM

3-90

120

50/6

0R

ectifi

ca-

tion

2-4

12In

t90

Non

-re

cycl

eR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

62R

7847

A10

33S

ee F

ootn

ote

e.

TFM

212

050

/60

Rec

tifica

-tio

n2-

44,

10

Int

Dep

ends

on

MTX

XR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

ee B

elow

: Fo

otno

te e

R78

47A

1033

See

Foo

tnot

e e

.

TFM

3X3H

120

50/6

0R

ectifi

ca-

tion

2-4

4, 1

0In

tD

epen

ds

on M

TXX

Non

-re

cycl

eR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

ee B

elow

: Fo

otno

te e

R78

47A

1033

See

Foo

tnot

e e

.

UV

M1D

di

scon

tinue

d in

199

9

120

50/6

0U

ltarv

iole

t0.

810

Int

Rel

ight

RM

7895

A10

14R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

ST7

800A

1005

R78

49A

1015

Sel

ect a

ppro

pria

te H

oney

wel

l Ultr

avio

let fl

ame

dete

ctor

UV

M1F

di

scon

tinue

d in

199

9

120

50/6

0U

ltarv

iole

t4

10In

tR

elig

htR

M78

95A

1014

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

05R

7849

A10

23S

elec

t app

ropr

iate

Hon

eyw

ell U

ltrav

iole

t flam

e de

tect

or

UV

M-2

A12

050

/60

Ulta

rvio

let

2-4

12In

t30

RM

7895

A10

14

RM

7895

B10

13R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

ST7

800A

1039

R78

49A

1023

See

Foo

tnot

e e

. P

lus

sele

ct a

ppro

pria

te H

oney

wel

l Ultr

avio

let fl

ame

dete

ctor

UV

M-2

A7

120

50/6

0U

ltarv

iole

t2-

412

Int

7R

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00”

R71

20M

1001

ST7

800A

1013

R78

49A

1023

See

Foo

tnot

e e

.

UV

M-2

A30

120

50/6

0U

ltarv

iole

t2-

412

Int

30R

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

39R

7849

A10

23S

ee F

ootn

ote

e.

Plu

s se

lect

app

ropr

iate

Hon

eyw

ell U

ltrav

iole

t flam

e de

tect

or

UV

M-2

A90

120

50/6

0U

ltarv

iole

t2-

412

Int

90R

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

62R

7849

A10

23S

ee F

ootn

ote

e.

Plu

s se

lect

app

ropr

iate

Hon

eyw

ell U

ltrav

iole

t flam

e de

tect

or

UV

M3-

712

050

/60

Ulta

rvio

let

2-4

12In

t7

Non

-re

cycl

eR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

13R

7849

A10

23S

ee F

ootn

ote

e.

Plu

s se

lect

app

ropr

iate

Hon

eyw

ell U

ltrav

iole

t flam

e de

tect

or

UV

M3-

9012

050

/60

Ulta

rvio

let

2-4

12In

t90

Non

-re

cycl

eR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

62R

7849

A10

23S

ee F

ootn

ote

e.

Plu

s se

lect

app

ropr

iate

Hon

eyw

ell U

ltrav

iole

t flam

e de

tect

or

UV

M2

120

50/6

0U

ltarv

iole

t2-

44,

10

Int

Dep

ends

on

MTX

XR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

ee B

elow

: Fo

otno

te e

R78

49A

1023

See

Foo

tnot

e e

. P

lus

sele

ct a

ppro

pria

te H

oney

wel

l Ultr

avio

let fl

ame

dete

ctor

Con

tinue

d on

nex

t pag

e >>

Page 28: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 26

Honeywell Primary Control Cross ReferenceTA

BLE

13—

HO

NEY

WEL

L C

RO

SS-R

EFER

ENC

E FO

R F

IREY

ETM T

FM A

ND

UVM

REP

LAC

EMEN

T

Dev

ice

to b

e R

epla

ced

RM

789X

/R71

20 R

epla

cem

ent

Volta

ge

(Vac

)Fr

e-qu

ency

(H

z)

Flam

e De

tete

ctor

Ty

pe

FFR

T (s

ec)

PFEP

(s

ec)

Pilo

t Ty

pe

(Int/I

tr)

a

Pre-

purg

e Ti

min

g

(Sec

)

Com

-m

ents

RM

7895

R

epla

cem

ent

b c

Enha

nced

R

M78

9X

Rep

lace

men

t b

c

R71

20

Rep

lace

-m

ent

c d

Purg

e Ti

mer

Am

plifi

erR

M78

9X/R

7120

Com

men

ts

UV

M3-

3H12

050

/60

Ulta

rvio

let

2-4

4, 1

0In

tD

epen

ds

on M

TXX

Non

-re

cycl

eR

M78

95A

1014

R

M78

95B

1013

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

ee B

elow

: Fo

otno

te e

R78

49A

1023

See

Foo

tnot

e e

. P

lus

sele

ct a

ppro

pria

te H

oney

wel

l Ultr

avio

let fl

ame

dete

ctor

UV

M5

120

50/6

0U

ltarv

iole

t2-

44,

10

ItrD

epen

ds

on M

TXX

Non

-re

cycl

eR

M78

95C

1012

R

M78

95D

1011

RM

7897

C10

00R

7120

M10

19S

ee B

elow

: Fo

otno

te e

R78

49A

1023

See

Foo

tnot

e e

. P

lus

sele

ct a

ppro

pria

te H

oney

wel

l Ultr

avio

let fl

ame

dete

ctor

(con

tinue

d)

FOO

TNO

TES

:a

In

t: In

term

itten

t, I

tr: In

terr

upte

db

Th

e R

M78

9X c

ontro

l is

not a

dire

ct p

lug

in re

plac

emen

t. S

ee M

oder

niza

tion

wiri

ng in

form

atio

n fo

r wiri

ng d

iagr

ams.

c

Rep

lace

men

t sug

gest

ions

hav

e fix

ed P

FEP

(4 o

r 10)

whe

re th

e Fi

reye

con

trol w

ent t

o R

un w

hen

(or s

hortl

y af

ter)

flam

e w

as s

ense

d.d

R

7120

sug

gest

ion

is a

dire

ct p

lug

in re

plac

emen

t.e

SUG

GES

TED

PU

RG

E TI

MER

FO

R M

2, 3

, 5 R

EPLA

CEM

ENT

Dev

ice

to b

e R

epla

ced

RM

789X

/R71

20 R

epla

cem

ent

Purg

e Ti

min

gPT

FI

Tim

ing

Purg

e Ti

mer

Com

men

ts

MT5

55

5S

T780

0A10

13C

lip J

R1

Rep

lace

men

t has

7 s

ec p

urge

, 4 s

ec F

FRT

MT7

47

4S

T780

0A10

13C

lip J

R1

MT3

0430

4S

T780

0A10

39C

lip J

R1

MT7

107

10S

T780

0A10

13

MT9

0490

4S

T780

0A10

62C

lip J

R1

MT3

010

3010

ST7

800A

1039

MT6

010

6010

ST7

800A

1054

MT9

010

9010

ST7

800A

1062

Page 29: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

27 95-6855—15

Honeywell Primary Control Cross Reference

MII

REP

LAC

EMEN

T: T

he M

II is

of s

olid

sta

te d

esig

n M

odul

ar M

ser

ies.

The

follo

win

g co

mpo

nent

s ne

ed to

be

know

n fo

r sel

ectin

g th

e H

oney

wel

l rep

lace

men

t dev

ices

. •

Con

trol C

hass

is •

Pro

gram

Mod

ule

alon

g w

ith d

ip s

witc

h se

tting

s •

Flam

e A

mpl

ifier

Mod

ule

Tabl

e 14

—Pr

ogra

m M

odul

e fo

r MII

Dev

ice

to b

e R

epla

ced

Rep

lace

men

t

a

Pilo

t Ty

pe

(Int/I

tr)

Tria

l for

Ig

nitio

n (s

ec)

Com

men

tsb

c

RM

789X

R

epla

cem

ent

b c

En

hanc

ed

RM

789X

Re

plac

emen

t

c d

R

7120

Re

plac

emen

t

RM

789X

/R

7120

Pu

rge

Tim

er

Com

men

ts

MP

100

Int

10en

ergi

zes

mai

n va

lve

whe

n fla

me

sens

edR

M78

95A

1014

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

13H

oney

wel

l rep

lace

men

t has

full

PFE

P be

fore

Mai

n en

ergi

zed

MP

101

Int

10A

llow

s fla

me

in

stan

dby

RM

7895

A10

14S

T780

0A10

13H

oney

wel

l rep

lace

men

t has

full

PFE

P be

fore

Mai

n en

ergi

zed

Hon

eyw

ell d

oes

not a

llow

flam

e in

sta

ndby

MP

102

Int

5en

ergi

zes

mai

n va

lve

whe

n fla

me

sens

edR

M78

95A

1014

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

13C

lip J

R1

or (o

rang

e ju

mpe

r on

R77

95) f

or 4

sec

PFE

P;

Hon

eyw

ell r

epla

cem

ent h

as fu

ll P

FEP

befo

re M

ain

ener

gize

d

MP

230

Int

10en

ergi

zes

mai

n va

lve

whe

n fla

me

sens

edR

M78

95A

1014

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

ee D

ip

Sw

itch

1-5

Che

ck d

ip s

witc

hes

for p

urge

, PTF

I, re

cycl

e/no

n re

cycl

e fo

r rep

lace

-m

ent f

eatu

res

MP2

30H

Int

103

seco

nd ig

nitio

n cu

tout

bef

ore

mai

n va

lve

ener

gize

d (P

ilot

Sta

biliz

atio

n pe

riod)

.

RM

7895

A10

14R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

See

Dip

S

witc

h 1-

5C

heck

dip

sw

itche

s fo

r pur

ge, P

TFI,

recy

cle/

non

recy

cle

for r

epla

ce-

men

t fea

ture

s;

Hon

eyw

ell r

epla

cem

ent h

as fu

ll P

FEP

befo

re M

ain

ener

gize

d

MP

560

Itr10

3 s

econ

d ig

nitio

n cu

tout

, 10

sec

MTF

I w

ith ru

n/te

st S

witc

h

RM

7895

C10

12R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

See

Dip

S

witc

h 1-

5C

heck

dip

sw

itche

s fo

r pur

ge, P

TFI,

recy

cle/

non

recy

cle

for r

epla

ce-

men

t fea

ture

s;

Hon

eyw

ell r

epla

cem

ent h

as fu

ll P

FEP

befo

re M

ain

ener

gize

d

MP

561

Itr10

lock

out o

n Fl

ame

Failu

re a

nd ru

nnin

g in

terlo

cks

with

run/

test

Sw

itch

RM

7895

C10

12R

M78

97A

1002

R

M78

98A

1000

R71

20M

1019

See

Dip

S

witc

h 1-

5C

lip J

R2

& 3

for R

M78

9X/R

7120

dev

ice.

MP

562

Itr10

8 se

cond

pilo

t sta

bili-

zatio

n tim

e an

d lo

ck-

out o

n lo

ss o

f run

ning

in

terlo

cks

with

run/

test

Sw

itch

RM

7895

C10

12R

M78

97A

1002

R

M78

98A

1000

See

Dip

S

witc

h 1-

5C

lip J

R3

for R

M78

9X/R

7120

dev

ice

FOO

TNO

TES

:a

In

t: In

term

itten

t, I

tr: In

terr

upte

db

Th

e R

M78

9X c

ontro

l is

not a

dire

ct p

lug

in re

plac

emen

t . S

ee M

oder

niza

tion

wiri

ng in

form

atio

n fo

r wiri

ng d

iagr

ams.

c

Rep

lace

men

t sug

gest

ions

hav

e fix

ed P

FEP

(4 o

r 10)

whe

re th

e Fi

reye

con

trol w

ent t

o R

un w

hen

(or s

hortl

y af

ter)

flam

e w

as s

ense

d.d

R

7120

sug

gest

ion

is a

dire

ct p

lug

in re

plac

emen

t.

Page 30: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 28

Honeywell Primary Control Cross ReferenceC

ontr

ol C

hass

is fo

r MII

Dev

ice

to b

e

Rep

lace

dVo

ltage

(V

ac)

Freq

ency

(H

z)C

omm

ents

for

7800

Rep

lace

men

tM

C12

012

050

/60

MC

120R

120

50/6

0A

dd S

7820

A10

07 R

emot

e R

eset

Mod

ule

MC

120P

120

50/6

0S

elec

t RM

7896

mod

el o

r pro

gram

enh

ance

d re

plac

e-m

ent (

post

pur

ge)

MC

230

230

50/6

0S

elec

t EC

7895

A or

EC

7895

C

MC

230R

230

50/6

0S

elec

t EC

7895

A or

EC

7895

C a

nd a

dd S

7820

A10

07

Rem

ote

Res

et M

odul

e

Dip

Sw

itch

setti

ngs

Switc

hO

ffO

n(M

P561

)R

epla

cem

ent C

omm

ents

15

5A

dd ti

min

gs o

f ‘O

n’ s

witc

hes

1-5

and

sele

ct c

lose

st

ST7

800

purg

e tim

er, p

ick

equa

l or n

ext h

ighe

st

timin

g.2

77

330

15

460

30

524

060

65

(PTF

I)

710

(PTF

I)

8R

ecyc

leN

on R

e-cy

cle

Flam

e A

mpl

ifier

Mod

ule

for M

II R

epla

cem

ent

Dev

ice

to b

e R

epla

ced

Rep

lace

men

t Sug

gest

ion

FFR

T (s

ec)

Flam

e D

etec

tion

Type

For R

M78

9X

R71

20

Rep

lace

men

t

Com

men

tsR

7120

com

men

ts

MA

UV

12-

4U

ltrav

iole

tR

7849

A10

23S

elec

t app

ropr

iate

C70

27

Ultr

avio

let r

epla

cem

ent.

Con

nect

C70

27 B

lue

wire

to S

2 an

d W

hite

wire

to S

1

MA

UV

1T0.

8U

ltrav

iole

tR

7849

A10

15S

elec

t app

ropr

iate

C70

27

Ultr

avio

let r

epla

cem

ent.

Con

nect

C70

27 B

lue

wire

to S

2 an

d W

hite

wire

to S

1

MA

RT1

2-4

Rec

tifica

tion

R78

47A

1033

Use

exi

stin

g fla

me

rod.

MA

RT1

T0.

8R

ectifi

catio

nR

7847

A10

25U

se e

xist

ing

flam

e ro

d.

Page 31: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

29 95-6855—15

Honeywell Primary Control Cross Reference

Mic

roM

REP

LAC

EMEN

T: T

he M

icro

M is

of m

icro

proc

esso

r bas

ed d

esig

n M

odul

ar M

ser

ies.

The

follo

win

g co

mpo

nent

s ne

ed to

be

know

n fo

r sel

ectin

g th

e H

oney

wel

l re

plac

emen

t dev

ices

. •

Con

trol C

hass

is •

Pro

gram

Mod

ule

alon

g w

ith d

ip s

witc

h se

tting

s •

Flam

e A

mpl

ifier

Mod

ule

• O

ptio

nal P

lug

In B

oard

Tabl

e 15

—C

ontr

ol C

hass

is fo

r the

Mic

ro M

(for

use

with

MEP

1XX,

MEP

2XX,

and

MEP

5XX)

Dev

ice

to b

e R

epla

ced

Volta

ge

(Vac

)Fr

eque

ncy

(Hz)

Feat

ure

Com

men

ts fo

r RM

789X

/R71

20 R

epla

cem

ent

ME

C12

012

050

/60

ME

C12

0C12

050

/60

Com

mun

icat

ions

Add

S78

10M

1003

or u

se S

7800

A10

01 K

eybo

ard

Dis

play

(S78

00A

1142

for E

nhan

ced

Rep

lace

men

t) an

d pr

ogra

m

for M

odB

usM

EC

120D

120

50/6

0D

ispl

ay F

eatu

reA

dd S

7800

A10

01 K

eybo

ard

Dis

play

(S78

00A

1142

for E

nhan

ced

Rep

lace

men

t)M

EC

120R

120

50/6

0R

emot

e R

eset

Add

S78

20A

1007

Rem

ote

Res

et M

odul

eM

EC

120R

C12

050

/60

Res

et a

nd

Com

mun

icat

ions

Add

S78

10M

1003

or u

se S

7800

A10

01 K

eybo

ard

Dis

play

(S78

00A

1142

for E

nhan

ced

Rep

lace

men

t) an

d pr

ogra

m

for M

odB

us a

nd c

onne

ct u

npow

ered

rese

t but

ton

to d

ispl

ay’s

term

inal

s 3

and

5.M

EC

120R

D12

050

/60

Res

et a

nd D

ispl

ayA

dd S

7800

A10

01 K

eybo

ard

Dis

play

(S78

00A

1142

for E

nhan

ced

Rep

lace

men

t) C

onne

ct u

npow

ered

rese

t but

ton

to d

ispl

ay’s

term

inal

s 3

and

5.M

EC

230

230

50/6

0R

eset

, Dis

play

and

C

omm

unic

atio

nsS

elec

t EC

7895

A or

EC

7895

C; u

se S

7800

Key

boar

d di

spla

y an

d pr

ogra

m fo

r Mod

Bus

and

con

nect

unp

ower

ed

rese

t but

ton

to d

ispl

ay’s

term

inal

s 3

and

5

Tabl

e 16

—C

ontr

ol C

hass

is fo

r the

Mic

ro M

(for

use

with

MEP

3XX,

MEP

4XX,

and

MEP

6XX)

Dev

ice

to b

e R

epla

ced

Volta

ge

(Vac

)Fr

eque

ncy

(Hz)

Feat

ure

Com

men

ts fo

r RM

789X

/R71

20 R

epla

cem

ent

ME

C32

012

050

/60

Sta

ndar

d pl

ug in

boa

rdM

EC

320R

120

50/6

0R

emot

e R

eset

Add

S78

20A

1007

Rem

ote

Res

et M

odul

eM

EC

320D

120

50/6

0D

ispl

ay F

eatu

reA

dd S

7800

A10

01 K

eybo

ard

Dis

play

(S78

00A

1142

for E

nhan

ced

Rep

lace

men

tM

EC

320R

D12

050

/60

Rem

ote

Res

et a

nd D

ispl

ay

Add

S78

00A

1001

Key

boar

d D

ispl

ay (S

7800

A11

42 fo

r Enh

ance

d R

epla

cem

ent w

ire

rem

ote

rese

t to

term

inal

s 3

and

5.M

EC

320C

120

50/6

0C

omm

unic

atio

nsA

dd S

7810

M10

03 o

r use

S78

00 K

eybo

ard

disp

lay

and

prog

ram

for M

odB

usM

EC

320R

C12

050

/60

Res

et a

nd C

omm

unic

atio

nsA

dd S

7810

M10

03 o

r use

S78

00 K

eybo

ard

disp

lay

and

prog

ram

for M

odB

us w

ire re

mot

e re

set t

o te

rmin

als

3 an

d 5.

ME

C32

0TS

120

50/6

0D

ispl

ay in

terfa

ce to

ED

510,

Mod

bus

inte

r-fa

ce, A

ux. r

elay

for c

ontro

ller M

ED

8A

dd S

7800

Key

boar

d di

spla

y an

d pr

ogra

m fo

r Mod

bus

ME

C48

023

050

/60

Cha

ssis

for M

EP

3XX

, ME

P4X

X o

r ME

P6X

XS

elec

t EC

7895

A or

EC

7895

C;

ME

C48

0RC

230

50/6

0R

eset

and

Com

mun

icat

ions

Sel

ect E

C78

95A

or E

C78

95C

; use

S78

00 K

eybo

ard

disp

lay

and

prog

ram

for M

odB

us

and

add

rese

t but

ton

to a

ppro

pria

te te

rmin

als

Page 32: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 30

Honeywell Primary Control Cross ReferenceTa

ble

17—

Opt

iona

l Plu

g-In

Boa

rd M

odul

es fo

r the

Mic

ro M

Dev

ice

to b

e R

epla

ced

Rep

lace

men

t Sug

gest

ion

Mod

elFe

atur

e

ME

D1

Sta

ndar

d lo

cal r

eset

sw

itch

Sta

ndar

d H

oney

wel

l dev

ice

ME

D2

Sta

ndar

d lo

cal r

eset

sw

itch

with

dis

play

out

put

Add

S78

00 d

ispl

ay to

RM

789X

/R71

20M

ED

3S

tand

ard

loca

l res

et s

witc

h w

ith re

mot

e re

set

Add

S78

20A

1007

to R

M78

9X/R

7120

ME

D4

Sta

ndar

d lo

cal r

eset

sw

itch

Sta

ndar

d H

oney

wel

l dev

ice

ME

D5

Sta

ndar

d lo

cal r

eset

sw

itch

with

dis

play

out

put a

nd R

S48

5 co

mm

unic

atio

nsA

dd S

7800

dis

play

to R

M78

9X/R

7120

and

con

figur

e fo

r Mod

Bus

ME

D6

Sta

ndar

d lo

cal r

eset

sw

itch

with

dis

play

out

put,

rem

ote

rese

t and

RS

485

com

mun

ica-

tions

Add

S78

00 d

ispl

ay to

RM

789X

/R71

20 a

nd c

onfig

ure

for M

odB

us, a

nd c

on-

nect

unp

ower

ed re

set t

o di

spla

y’s

term

inal

s 3

and

5.M

ED

7S

tand

ard

loca

l res

et s

witc

h w

ith R

S48

5 co

mm

unic

atio

nsA

dd S

7810

M10

03 fo

r Mod

bus

to R

M78

9X/R

7120

and

con

nect

unp

ower

ed

rese

t to

disp

lay’

s te

rmin

als

3 an

d 5.

Or a

dd S

7800

dis

play

and

con

figur

e fo

r m

odbu

s.M

ED

8S

tand

ard

loca

l res

et s

witc

h w

ith d

ispl

ay o

utpu

t and

RS

485

Mod

bus

inte

rface

and

aux

il-ia

ry re

lay

outp

ut w

ith n

orm

ally

clo

sed

dry

cont

act f

or c

ontro

ller i

nter

face

No

Mat

ch fo

r dry

con

tact

out

put f

eatu

re.

ME

D9

Sta

ndar

d lo

cal r

eset

sw

itch

with

dis

play

out

put a

nd R

S48

5 M

odbu

s in

terfa

ce a

nd a

uxil-

iary

rela

y ou

tput

with

nor

mal

ly o

pen

dry

cont

act f

or c

ontro

ller i

nter

face

No

Mat

ch fo

r dry

con

tact

out

put f

eatu

re.

Page 33: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

31 95-6855—15

Honeywell Primary Control Cross Reference

Tabl

e 18

—M

icro

M P

rogr

am M

odul

e (fo

r use

with

MEC

120

and

MEC

230

cha

ssis

)D

evic

e to

be

Rep

lace

dR

epla

cem

ent S

ugge

stio

nM

odel

Feat

ure

RM

7895

or

RM

7896

R

epla

cem

ent

Enha

nced

78

00

Rep

lace

men

t

R71

20

Rep

lace

men

tPr

epur

ge T

imer

(r

equi

red

for

RM

789X

or

R71

20)

Com

men

ts

ME

P10

0In

term

itten

t Pilo

t, R

elig

ht, 1

0 P

TFI

RM

7895

A10

14R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

ST7

800A

1005

Rep

lace

men

t sug

gest

ions

has

a c

ompl

ete

PFE

P, F

ireye

cut

s of

f whe

n fla

me

sens

ed.

ME

P10

0PM

EP

100

with

15

sec.

pos

t pur

geR

M78

96A

1012

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

05R

epla

cem

ent s

ugge

stio

ns h

as a

com

plet

e P

FEP,

Fire

ye c

uts

off w

hen

flam

e se

nsed

. Pro

gram

RM

7897

or R

M78

98 fo

r 15

seco

nd p

ost p

urge

ME

P10

1sa

me

as M

EP

100

but a

llow

s fla

me

durin

g ‘o

ff’ c

ycle

RM

7895

A10

14R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

ST7

800A

1005

Rep

lace

men

t sug

gest

ions

has

a c

ompl

ete

PFE

P, F

ireye

cut

s of

f whe

n fla

me

sens

ed. R

epla

cem

ent R

M d

oes

not a

llow

flam

e du

ring

‘off’

cyc

le

ME

P10

2sa

me

as M

EP

100

with

10

sec.

PTF

I, Lo

ckou

t on

flam

e fa

ilure

.R

M78

95A

1014

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

05R

epla

cem

ent s

ugge

stio

ns h

as a

com

plet

e P

FEP,

Fire

ye c

uts

off w

hen

flam

e se

nsed

. Clip

JR

1 an

d JR

2

ME

P10

3Fi

xed

10 s

ec. S

park

Igni

tor S

ensi

ng

Per

iod

follo

wed

by

a 10

sec

. MTF

I, w

ith 3

0 se

cond

pos

t pur

ge. W

ill re

try

once

on

igni

tor f

ailu

re

Non

eN

one

Non

eN

o H

oney

wel

l sug

gest

ion

for t

his

spar

k fe

atur

e.

ME

P10

4M

EP

100

with

10

sec.

PTF

I, Lo

ckou

t on

flam

e fa

ilure

.R

M78

95A

1014

RM

7897

A10

02

RM

7898

A10

00R

7120

M10

01S

T780

0A10

05R

epla

cem

ent s

ugge

stio

ns h

as a

com

plet

e P

FEP,

Fire

ye c

uts

off w

hen

flam

e se

nsed

. Clip

JR

2

ME

P10

5N

on re

cycl

e on

flam

e fa

il, lo

ckou

t on

limit

failu

re, 1

0 se

c. P

TFI

RM

7895

A10

14R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

ST7

800A

1005

Rep

lace

men

t sug

gest

ions

has

a c

ompl

ete

PFE

P, F

ireye

cut

s of

f whe

n fla

me

sens

ed. C

lip J

R2

and

JR3

ME

P23

0E

quip

ed w

ith d

ip s

witc

hes

to s

elec

t: P

repu

rge

timin

g, P

TFI,

post

pur

ge,

recy

cle/

non

recy

cle

on m

ain

flam

e lo

ss, a

nd p

rove

n op

en to

sta

rt ai

r flow

sw

itch.

Igni

tion

turn

s of

f 3 s

econ

ds

befo

re m

ain

valv

e en

ergi

zed.

See

Tab

le 2

1.S

ee T

able

21.

Clip

JR

3

ME

P23

0Hsa

me

as M

EP

230

with

8 s

ec. p

ilot

stab

iliza

tion

perio

d.S

ee T

able

21.

See

Tab

le 2

1.R

M78

9X o

r R71

20 h

as 1

0 se

cond

PFE

P, b

ut N

OT

pilo

t sta

biliz

atio

n fe

atur

e, R

M78

98A

1018

has

a e

arly

spa

rk te

rmin

atio

n w

hen

flam

e is

se

nsed

.

ME

P23

4S

elec

tabl

e: P

TFI,

prep

urge

tim

ing,

pr

ove

limits

ope

n on

sta

rt, 1

0 se

c.

Pilo

t pro

ving

, MTF

I, po

st p

urge

, non

re

cycl

e on

flam

e fa

il.

RM

7896

B10

11N

one

Non

eS

ee T

able

21.

Clip

JR

2 an

d JR

3

ME

P23

5M

EP

230

with

lock

out o

n lim

its o

pen

10 s

ec. a

fter s

tart,

sel

ecta

ble

recy

cle/

non

recy

cle

on o

pen

afte

r flam

e is

pr

oven

, ded

icat

ed lo

ckou

t on

loss

of

flam

e

See

Tab

le 2

1.S

ee T

able

21.

Clip

JR

2 an

d JR

3

ME

P23

6sa

me

as M

EP

230

with

6 s

ec. a

d-di

tiona

l ign

ition

on

with

mai

n fu

el (f

or

use

with

inte

rmitt

ent p

ilot o

nly)

.

RM

7895

A10

14R

M78

97A

1002

R

M78

98A

1000

R71

20M

1001

See

Tab

le 2

1.R

M78

9X o

r R71

20 d

oes

not k

eep

the

igni

tion

on in

to th

e m

ain

flam

e es

tabi

shin

g tim

e

ME

P23

7S

ame

as M

EP

230,

fixe

d P

TFI,

Inte

r-ru

pted

pilo

t, us

e M

ED

C2

amp

for 8

5 &

95

ser

ies

scan

ners

Non

eN

one

Non

eN

one

No

Hon

eyw

ell d

evic

e fo

r thi

s sc

anne

r ser

ies

Page 34: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 32

Honeywell Primary Control Cross ReferenceTa

ble

18—

Mic

roM

Pro

gram

Mod

ule

(for u

se w

ith M

EC12

0 an

d M

EC 2

30 c

hass

is)

Dev

ice

to b

e R

epla

ced

Rep

lace

men

t Sug

gest

ion

Mod

elFe

atur

eR

M78

95 o

r R

M78

96

Rep

lace

men

t

Enha

nced

78

00

Rep

lace

men

t

R71

20

Rep

lace

men

tPr

epur

ge T

imer

(r

equi

red

for

RM

789X

or

R71

20)

Com

men

ts

ME

P23

8S

ame

as M

EP

230,

igni

tion

shut

off

3 se

c af

ter fl

ame

sens

e, 8

sec

pilo

t st

abili

zatio

n pe

riod

RM

7895

A10

48R

M78

98A

1018

Non

eS

ee T

able

21.

RM

7895

/8 h

as a

fixe

d P

FEP

so p

ilot s

tabi

lizat

ion

time

depe

ndan

t on

how

soo

n fla

me

is s

ense

d.

ME

P29

0sa

me

as M

EP

230H

with

0 o

r 90

sec-

ond

post

pur

ge.

See

Tab

le 2

1.S

ee T

able

21.

Pro

gram

RM

7897

, RM

7898

R71

20 fo

r 90

seco

nd p

ost p

urge

. RM

789X

or

R71

20 h

as 1

0 se

cond

PFE

P, b

ut N

OT

pilo

t sta

biliz

atio

n fe

atur

e,

RM

7898

A10

18 h

as a

ear

ly s

park

term

inat

ion

whe

n fla

me

is s

ense

d.

ME

P30

0R

elig

ht o

pera

tion,

10

sec

fixed

PTF

I, 5

seco

nd p

ilot p

rovi

ng p

erio

d, 5

sec

ond

MTF

I, lo

ckou

t on

flam

e fa

il du

ring

PTF

I, pi

lot p

rovi

ng a

nd M

TFI.

Rec

ycle

on

air

flow

ope

n, n

o po

st p

urge

, res

et

on li

ne v

olta

ge.

Non

eR

M78

97C

1018

Non

eS

ee T

able

21.

Sug

gest

ed c

ontro

l DO

ES

NO

T sh

ut o

ff ig

nitio

n fo

r 5 s

econ

d pi

lot p

rov-

ing

perio

d. R

M78

9X o

r R71

20M

requ

ires

cont

act c

losu

re re

set w

hen

usin

g S

7820

A10

07 m

odul

e

ME

P30

4no

n re

cylc

e on

flam

e fa

ilure

, 5 s

ec

purg

e, 1

0 se

c fix

ed P

TFI,

5 se

c pi

lot

prov

ing,

10

sec

MTF

I, in

turr

upte

d pi

lot,

early

spa

rk te

rmin

atio

n.

RM

7895

C10

20R

M78

97C

1000

R

M78

98A

1018

R71

20M

1019

ST7

800A

1005

Sug

gest

ed R

M78

97C

or R

7120

M c

ontro

l DO

ES

NO

T sh

ut o

ff ig

nitio

n fo

r 5 s

econ

d pi

lot p

rovi

ng p

erio

d. R

M78

9X o

r R71

20M

requ

ires

cont

act

clos

ure

rese

t whe

n us

ing

S78

20A

1007

mod

ule

Clip

JR

2

ME

P33

5N

on re

cycl

e on

flam

e fa

il, 3

0 se

c pu

rge,

35

sec

hot s

urfa

ce ig

nitio

n on

te

rmin

al 4

, 3 s

ec P

TFI o

n te

rmin

al 3

, 5

seco

nd p

ilot p

rovi

ng p

erio

d, in

term

it-te

nt p

ilot,

15 s

econ

d po

st p

urge

, M

anua

l res

et o

nly.

Non

eN

one

Non

eH

oney

wel

l doe

s no

t offe

r 35

seco

nd h

ot s

urfa

ce d

evic

e

ME

P39

7R

ecyc

le o

n m

ain

flam

e fa

il, 1

5 se

cond

pu

rge,

7 s

econ

d fix

ed P

TFI,

5 se

cond

pi

lot p

rovi

ng 5

sec

MTF

I, ea

rly s

park

te

rmin

atio

n an

d in

turr

upte

d pi

lot.

Rec

ycle

on

air fl

ow fa

ilure

, no

post

pu

rge,

run

chec

k sw

itch,

rese

t on

line

volta

ge.

Non

eR

M78

97C

1018

Non

eS

T780

0A10

21

or

ST7

800A

1039

(n

o 15

pur

ge

avai

labl

e)

Sug

gest

ed c

ontro

l DO

ES

NO

T sh

ut o

ff ig

nitio

n fo

r 5 s

econ

d pi

lot p

rov-

ing

perio

d. R

M78

9X o

r R71

20M

requ

ires

cont

act c

losu

re re

set w

hen

usin

g S

7820

A10

07 m

odul

e

ME

P43

7R

ecyc

le o

nce

on m

ain

flam

e fa

ilure

, se

lect

able

5 o

r 10

sec

fixed

PTF

I, se

lect

able

inte

rrup

ted

or in

term

itten

t pi

lot,

5 se

c M

TFI,

sele

ctab

le p

urge

tim

e to

240

sec

onds

, mai

n va

lve

proo

f of

clo

sure

, 15

seco

nd p

ost p

urge

, re

set o

n lin

e vo

ltage

.

Non

eR

M78

97A

1002

fo

r Int

erm

itten

t, R

M78

97C

1000

fo

r Int

erru

pted

or

RM

7898

A10

00

Non

eS

ee T

able

21.

Sug

gest

ed c

ontro

l DO

ES

NO

T of

fer 5

sec

MFE

P (M

TFI)

requ

ires

cont

act c

losu

re re

set w

hen

usin

g S

7820

A10

07 m

odul

e or

S78

00A

1142

di

spla

y, u

se d

ispl

ay to

pro

gram

15

seco

nd p

ost p

urge

, PO

C is

sep

arat

e in

put t

o R

M.

ME

P53

6sa

me

as M

EP

560

with

out p

ilot s

tabi

-liz

atio

n pe

riod.

Will

not

lock

out o

n ai

r flo

w o

pen

durin

g pu

rge

perio

d.

If sw

itch

3 cl

osed

R

M78

95D

1011

or

If

switc

h 3

open

R

M78

96D

1019

RM

7897

C10

00

or

RM

7898

A10

18

R71

20M

1019

See

Tab

le 2

1.R

M78

9X/R

7120

sug

gest

ion,

doe

s N

OT

offe

r spe

cial

Airfl

ow s

witc

h fe

atur

e.

(con

tinue

d)

Page 35: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

33 95-6855—15

Honeywell Primary Control Cross Reference

Tabl

e 18

—M

icro

M P

rogr

am M

odul

e (fo

r use

with

MEC

120

and

MEC

230

cha

ssis

)D

evic

e to

be

Rep

lace

dR

epla

cem

ent S

ugge

stio

nM

odel

Feat

ure

RM

7895

or

RM

7896

R

epla

cem

ent

Enha

nced

78

00

Rep

lace

men

t

R71

20

Rep

lace

men

tPr

epur

ge T

imer

(r

equi

red

for

RM

789X

or

R71

20)

Com

men

ts

ME

P53

7sa

me

as M

EP

536

exce

pt p

rovi

des

one

recy

cle

on m

ain

flam

e fa

ilure

.If

switc

h 3

clos

ed

RM

7895

D10

11

or

If sw

itch

3 op

en

RM

7896

D10

19

RM

7897

C10

00

or

RM

7898

A10

00

R71

20M

1019

See

Tab

le 2

1.R

M78

97, R

M78

98, R

7120

do

NO

T of

fer d

ynam

ic A

FS F

eatu

re.

RM

789X

or R

7120

M d

o N

OT

offe

r one

recy

cle,

C

lip J

R3

to lo

ckou

t on

mai

n fla

me

failu

re.

ME

P56

0sa

me

as M

EP

230H

with

10

sec.

MTF

I, R

un-C

heck

sw

itch.

8 s

econ

d pi

lot s

ta-

biliz

atio

n be

fore

mai

n va

lve

ener

gize

d.

If sw

itch

3 cl

osed

R

M78

95D

1011

or

If

switc

h 3

open

R

M78

96D

1019

RM

7897

C10

00

or

RM

7898

A10

18

R71

20M

1019

See

Tab

le 2

1.R

M78

9X 1

0 se

cond

PFE

P, b

ut N

OT

pilo

t sta

biliz

atio

n fe

atur

e,

RM

7898

A10

18 h

as a

ear

ly s

park

term

inat

ion

whe

n fla

me

is s

ense

d so

so

me

pilo

t sta

biliz

atio

n tim

e.

RM

7897

, RM

7898

, R71

20 d

o N

OT

offe

r dyn

amic

AFS

Fea

ture

.

ME

P56

1sa

me

as M

EP

560

with

3 s

econ

d pi

lot

stab

iliza

tion

perio

d be

fore

mai

n va

lve

ener

gize

d, s

elec

tabl

e pu

rge

timin

gs o

f 7,

10,

15,

or 3

0 se

cond

s.

If sw

itch

3 cl

osed

R

M78

95D

1011

or

If

switc

h 3

open

R

M78

96D

1019

RM

7897

C10

00

or

RM

7898

A10

18

R71

20M

1019

See

Tab

le 2

1.R

M78

9X 1

0 se

cond

PFE

P, b

ut N

OT

pilo

t sta

biliz

atio

n fe

atur

e,

RM

7898

A10

18 h

as a

ear

ly s

park

term

inat

ion

whe

n fla

me

is s

ense

d so

so

me

pilo

t sta

biliz

atio

n tim

e.

RM

7897

, RM

7898

, R71

20 d

o N

OT

offe

r dyn

amic

AFS

Fea

ture

.

ME

P56

2sa

me

as M

EP

560

with

lock

out o

n lo

ss

of fl

ame

and

limit

circ

uit o

pen.

If sw

itch

3 cl

osed

R

M78

95D

1011

or

If

switc

h 3

open

R

M78

96D

1019

RM

7897

C10

00

or

RM

7898

A10

18

R71

20M

1019

See

Tab

le 2

1.R

M78

9X 1

0 se

cond

PFE

P, b

ut N

OT

pilo

t sta

biliz

atio

n fe

atur

e,

RM

7898

A10

18 h

as a

ear

ly s

park

term

inat

ion

whe

n fla

me

is s

ense

d so

so

me

pilo

t sta

biliz

atio

n tim

e.

RM

7897

, RM

7898

, R71

20 d

o N

OT

offe

r dyn

amic

AFS

Fea

ture

. Clip

JR

2 an

d JR

3,

ME

P56

4sa

me

as M

EP

560

with

3 s

econ

d pi

lot

stab

iliza

tion

perio

d be

fore

mai

n va

lve

ener

gize

d, s

elec

tabl

e pu

rge

timin

gs o

f 7,

30,

60,

or 2

40 s

econ

ds.

If sw

itch

3 cl

osed

R

M78

95D

1011

or

If

switc

h 3

open

R

M78

96D

1019

RM

7897

C10

00

or

RM

7898

A10

18

R71

20M

1019

See

Tab

le 2

1.R

M78

9X 1

0 se

cond

PFE

P, b

ut N

OT

pilo

t sta

biliz

atio

n fe

atur

e,

RM

7898

A10

18 h

as a

ear

ly s

park

term

inat

ion

whe

n fla

me

is s

ense

d so

so

me

pilo

t sta

biliz

atio

n tim

e.

RM

7897

, RM

7898

, R71

20 d

o N

OT

offe

r dyn

amic

AFS

Fea

ture

.

ME

P69

6P

rovi

des

30 s

econ

ds o

f pre

purg

e,

lock

out o

n ai

rflow

afte

r 10

seco

nds,

10

sec

PTF

I, 5

sec

pilo

t pro

ving

, ea

rly s

park

term

inat

ion,

5 s

ec M

TFI,

inte

rrup

ted

pilo

t, se

lect

able

recy

cle/

non

recy

cle

on fl

ame

failu

re, 6

0 se

c.

post

pur

ge, s

elec

tabl

e ba

ud ra

te fo

r co

mm

unic

atio

n, o

utpu

t for

ext

erna

l co

ntro

ller o

pera

tion.

RM

7897

C10

18S

T780

0A10

39S

ugge

sted

con

trol D

OE

S N

OT

shut

off

igni

tion

for 5

sec

ond

pilo

t pro

v-in

g pe

riod.

Use

S78

00A

1142

to p

rogr

am 6

0 se

cond

pos

t pur

ge a

nd s

et

up fo

r Mod

bus

Com

mun

icat

ions

. R

M78

97 d

oes

NO

T ha

ve o

utpu

t for

ext

erna

l con

trolle

r.

(con

tinue

d)

Page 36: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 34

Honeywell Primary Control Cross ReferenceTa

ble

19—

Avai

labl

e di

psw

itche

s fo

r MEP

200

and

500

serie

s.SW

ITC

HFU

NC

TIO

NC

OM

MEN

TS1

23

45

6

CC

a c 7

a c

PU

RG

E T

IME

S

EC

ON

DS

Sel

ect S

T780

0A10

13

OC

a c 30

Sel

ect S

T780

0A10

39

CO

a c 60

Sel

ect S

T780

0A10

54

OO

a c 90

Sel

ect S

T780

0A10

62

CD

ISA

BLE

Db

P

OS

T P

UR

GE

Sel

ect R

M78

95 o

r RM

7897

Ob

15

SE

CO

ND

Sb S

elec

t RM

7896

or R

M78

97 a

nd p

rogr

am p

ost p

urge

C5

PTF

I TI

ME

Clip

JR

1 fro

m y

our s

elec

tion

O10

Leav

e JR

1 in

tact

CD

ISA

BLE

PR

OV

E A

IR F

LOW

O

PE

N A

T S

TAR

TS

elec

t RM

7895

A/C

, 789

6A/C

or 7

897

OE

NA

BLE

Sel

ect R

M78

95B

/D, 7

896B

/D, n

o 78

97C

RE

CY

CLE

FLA

ME

FA

IL A

CTI

ON

FR

OM

RU

NLe

ave

JR2

inta

ct

ON

ON

-RE

CY

CLE

Clip

JR

2 fro

m y

our s

elec

tion

FOO

TNO

TES

:a

M

EP

561

mod

ule

has

sele

ctab

le p

urge

tim

ing

of 7

, 10,

15

and

30 s

econ

dsb

M

EP

290

mod

ule

has

sele

ctab

le p

ost p

urge

of 9

0 se

cond

s-on

ly R

M78

97 is

ava

ilabl

ec

M

EP

564

mod

ules

has

sel

ecta

ble

purg

e tim

ing

of 7

, 30,

60,

and

240

sec

onds

Page 37: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

35 95-6855—15

Honeywell Primary Control Cross Reference

Tabl

e 20

—Av

aila

ble

dips

witc

hes

for M

EP43

7SW

ITC

HFU

NC

TIO

NC

OM

MEN

TS1

23

45

6

CC

C0

PU

RG

E T

IME

S

ELE

CTI

ON

(s

econ

ds)

Sel

ect S

T780

0A10

05 (2

sec

min

imum

)O

CC

5S

elec

t ST7

800A

1013

(7 s

econ

ds)

CO

C15

Sel

ect S

T780

0A10

39 (3

0 se

cond

s, n

o 15

)O

OC

30S

elec

t ST7

800A

1039

(30

seco

nds,

no

15)

CC

O60

Sel

ect S

T780

0A10

54O

CO

90S

elec

t ST7

800A

1062

CO

O12

0S

elec

t ST7

800A

1070

(2.5

min

ute)

OO

O24

0S

elec

t ST7

800A

1088

C5

PTF

I TIM

E

(sec

onds

)C

lip J

R1

O10

Leav

e JR

1 In

tact

CIN

TER

RU

PTE

DP

ILO

T O

PE

RAT

ION

Leav

e JR

2 in

tact

O

INTE

RM

ITTE

NT

Clip

JR

2 fro

m y

our s

elec

tion

CR

EC

YC

LEFL

AM

E F

AIL

Leav

e JR

2 in

tact

O

NO

N-R

EC

YC

LEC

lip J

R2

from

you

r sel

ectio

n

TAB

LE 2

1—Fl

ame

Am

plifi

er fo

r the

Mic

ro M

Dev

ice

to b

e R

epla

ced

Rep

lace

men

tFF

RT

(sec

)Fl

ame

Am

p Ty

peFl

ame

Det

ecto

r Typ

eC

omm

ents

R71

20 c

omm

ents

ME

UV

10.

8N

on s

elf c

heck

Ultr

avio

let

R78

49A

1015

S

elec

t C70

27 fl

ame

dete

ctor

Con

nect

C70

27 B

lue

wire

to S

2 an

d W

hite

wire

to S

1M

EU

V4

3N

on s

elf c

heck

Ultr

avio

let

R78

49A

1023

S

elec

t C70

27 fl

ame

dete

ctor

Con

nect

C70

27 B

lue

wire

to S

2 an

d W

hite

wire

to S

1M

EU

VS

10.

8S

elf C

heck

Ultr

avio

let

R78

49B

1013

Sel

ect C

7027

flam

e de

tect

orC

onne

ct C

7027

Blu

e w

ire to

S2

and

Whi

te w

ire to

S1

ME

UV

S4

3S

elf C

heck

Ultr

avio

let

R78

49B

1021

S

elec

t C70

27 fl

ame

dete

ctor

Con

nect

C70

27 B

lue

wire

to S

2 an

d W

hite

wire

to S

1M

ER

T10.

8N

on s

elf c

heck

Flam

e R

odR

7847

A10

25U

se e

xist

ing

Flam

e R

odM

ER

T43

Non

sel

f che

ckFl

ame

Rod

R78

47A

1033

Use

exi

stin

g Fl

ame

Rod

ME

IR1

0.8

Non

sel

f che

ckIn

frare

dN

o 0.

8 se

cond

mod

elM

EIR

43

Non

sel

f che

ckIn

frare

dR

7852

A10

01

Sel

ect C

7915

flam

e de

tect

orM

EC

D1

0.8

Non

sel

f che

ckC

adm

ium

Sul

fide

R78

51B

1018

S

elec

t C79

62 fl

ame

dete

ctor

ME

CD

43

Non

sel

f che

ckC

adm

ium

Sul

fide

R78

51B

1000

S

elec

t C79

62 fl

ame

dete

ctor

ME

DC

2C

onta

ct In

put

With

ME

P23

7, o

pera

tion

with

85

and

95 s

erie

s sc

anne

rs.

Page 38: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

95-6855—15 36

Honeywell Primary Control Cross Reference

Page 39: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60

37 95-6855—15

Honeywell Primary Control Cross Reference

Page 40: 95-6855-15 - Honeywell Primary Control Cross Reference · 95-6855—15 4 Honeywell Primary Control Cross Reference FOOTNOTES: a EC7890 operating voltage is 187 Vac to 264 Vac 50/60