7745 – Alarm TRXCHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD

Page 2: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 2/22

2 © Nokia Siemens Networks. All rights reserved.

7745 - CHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD

MeaningThe rate of calls terminating in failure on a channel is above the thresholdvalue set by the operator. The alarm is used to supervise the functioning oftraffic and signaling channels, and to detect the possible faulty channels.Alarm in TRXlevel, reported in BSC

CategoryQuality of Services Alarm, Severity Medium

KeyWordWhenever a channel is released with a release cause other than a normal one ,the counter of channel failures for the released channel is incremented.

NSN Default Threshold :TCHFR = TCH failure rate (20 % or 30%)SCHFR = SDCCH failure rate (80 %)PRDCFR = length of supervision period (60 min)CS = channel seizure threshold value (10)

Page 3: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 3/22

3 © Nokia Siemens Networks. All rights reserved.

7745 - CHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD

Channel Release procedure

Whenever a channel is released with a release cause other than a normal one,the counter of channel failures for the released channel is incremented.After a certain observation time and a certain threshold it will reported in the7745 alarm. It give an indication that there’s a failure that need to beaddressed, but overall KPI need to be used as a first priority.

Page 4: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 4/22

4 © Nokia Siemens Networks. All rights reserved.

7745 - CHANNEL FAILURE RATE ABOVE DEFINEDTHRESHOLD

TCH Failure0A Channel state conflict between RRMPRB and ABIPRB0B Channel type conflict between RRMPRB and ABIPRB0D TCH radio failure0E Source TCH radio failure in HO0F Target TCH radio failure in HO1D TCH transcoder failure1E Source TCH transcoder failure in HO1F Target TCH transcoder failure in HO2E TCH failure due to a LAPD failure2F TCH failure due to a BTS failure30 TCH failure due to user actions31 TCH failure due to a BCSU reset32 TCH failure due to radio network reconfiguration actions

51 TCH activation failure during call set-up53 Target TCH activation failure in HO54 TCH failure due to an Abis interface failure in call set-up55 Source TCH failure due to an Abis interface failure in HO56 Target TCH failure due to an Abis interface failure in HO57 TCH failure due to an A interface failure in call set-up58 Source TCH failure due to an A interface failure in HO59 Target TCH failure due to an A interface failure in HOFF Actually no release cause, but causes all channels with

an abnormal release cause to be listed

SDCCH Failure03 SDCCH radio failure04 Source SDCCH radio failure in HO05 Target SDCCH radio failure in HO0A Channel state conflict between RRMPRB and ABIPRB

0B Channel type conflict between RRMPRB and ABIPRB23 SDCCH failure due to a LAPD failure24 SDCCH failure due to a BTS failure25 SDCCH failure due to user actions26 SDCCH failure due to a BCSU reset27 SDCCH failure due to radio network reconfiguration actions48 SDCCH activation failure during call set-up4A Target SDCCH activation failure in HO4B SDCCH failure due to an Abis interface failure in call set-up

4C Source SDCCH failure due to an Abis interface failure in HO4D Target SDCCH failure due to an Abis interface failure in HO4E SDCCH failure due to an A interface failure in call set-up4F Source SDCCH failure due to an A interface failure in HO50 Target SDCCH failure due to an A interface failure in HO

7745 alarm occurance in Telkomsel Network

Around 90% is affected in TCH, around 10% is affected in SDCCHAbnormal relase cause defined below :

Page 5: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 5/22

5 © Nokia Siemens Networks. All rights reserved.

7745 - Alarm Information<HIST> AKSES_UI BCF-0065 BTS-0156 QUAL 2009-01-13 13:51:49.59** ALARM TRX -006 JNCSILIWANGIMD2

DISABLED(60756) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD

01 00 01 01 01 01 01 00 00 04 00 48d

<HIST> AKSES_UI BCF-0065 BTS-0156 QUAL 2009-01-13 13:51:49.59.. CANCEL TRX -007 JNCSILIWANGIMD2

ENABLED(60755) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD

01 00 00 00 00 00 00 00 00 00 00 0d

Supplementary information fields1 indicates if the alarm is on the TCH or on the SDCCH channel 01: TCH 02: SDCCH2..9 indicates if the channel failure rate is above the defined threshold in time slot 0 00:

belove threshold (no alarm) 01: above threshold (alarm)10 time slot with the highest failure rate11 subchannel identification TCH: 00: TCH/H -subchannel 0 01: TCH/H -subchannel 1 02:

TCH/F -subchannel subchannel identification SDCCH: 00 - 07: SDCCH -subchannel 0 – 712 proportion/percentage of TCH or SDCCH subchannel releases due to failure in all

channel releases on a given channel during the measurement period

Page 6: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 6/22

6 © Nokia Siemens Networks. All rights reserved.

Tools or verification that have been performed so far byNSN before/during site visit• Basic SW for Monitoring NE

MML, BTS Manager

• KPI BrowserCell Doctor (report 211 Network Doctor) OSSCell KPI (report 204 Network Doctor) OSS

• Basic verification of site condition – for new sitesVSWR test verification (VSWR, RL, DTF verification)Verification of Main and Diversity receive levelTRX Test function from BTS manager

Page 7: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 7/227 © Nokia Siemens Networks. All rights reserved.

Step By Step SummaryFlowchart for investigation methodology

Root Cause&

Suplementaryinformation

SD& TCH

RR : TCH : 590F0D

SD : 4B4D

Check InstallationQuality

TroubleshootReport

ND 196 > uplink & downlink QualityND 195 > TRX by downlink /uplink level balanceND 232 > Time advance

Audit Neighbour & Paramater ADCE

Check Parameter / ARFCN

or Audit Antennatilting

Action

Unbalancefounded

Uplink & downlinkper TRX

Troubleshooting if before VSWR OK > check cable connection& arester / grounding

VSWRCheck

Coverage

Check crosssector founded

CR & Execute Monitoring Alarm& KPI

KPI OK Alarm

Justification for alarm :1. Countur 2. Remote3. Blocking & Fading4. Etc

CR & Execute Monitoring Alarm& KPI

End

Start 7745

TroubleshootingBCCH per feeder

NOK

OK

Alarm Clear & KPI OK

NOK

OK

TCH

SD

Page 8: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 8/228 © Nokia Siemens Networks. All rights reserved.

BTS installation standard

TX1,2 and RX main

TX 3,4 and RX div

Page 9: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 9/229 © Nokia Siemens Networks. All rights reserved.

If we have 7745, 7743 alarms in our network, what isreally happening?

Before Site Visit :Make sure Audit neighbor, TSC checking and TRXtest

Action on site :1. 7745, 7743 at one TRX only

- Check SMA cable at Tx connector to WCXA of the TRX, make sure properly connected- Replace TRX, BB2F and SMA cables if needed

2. 7745, 7743 at two TRX- Try to switch BCCH, if still appear potential have a partial cross feeder- Replace TRX, BB2F WCXA, or DVXA if needed- Check alarms of other sector to ensure analysis

3. 7745, 7743 at all TRXs under same cell- Possibilities error : full partial cross feeder, bad feeder quality and its connection,interference, broken DVXA

Page 10: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 10/2210 © Nokia Siemens Networks. All rights reserved.

If we have 7745, 7604 alarms in our network, what isreally happening?

If: VSWR have been checked,

Then: We can find out from hardware by checking its transmit path from TRxunit, Tx port, SMA-cables from Tx port to WCxA, WCxA itself, and so on, untilits feeder connection and antenna.

Thus:7604 alarm is usually related to degraded receive quality of one sector or oneTRx.

From hardware point of view:Check its receive path from TRx unit, Rx main and RxDiv port, SMA cablesfrom Rx port to M2xA, M2xA itself, and so on, until its feeder connection andantenna.

Page 11: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 11/2211 © Nokia Siemens Networks. All rights reserved.

Sample ND 196

Performance Analysis:IF: band q5 value is under 95%

THEN:we suspect that the TRX have badquality uplink or Downlink ( in this casedownlink issue)

Page 12: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 12/2212 © Nokia Siemens Networks. All rights reserved.

Sample ND 195

Base on BTS installation standard that :

“Uplink and Downlink between TRX in one sectoris maks 3db”

This report shows for each TRX:

Ave MS pwr attn /lb_11 Average MS power attenuation (dB)Ave BS pwr attn /lb_12 Average BS power attenuation (dB)Ave UL str /lb_9 Average UL signal strengthAve DL str /lb_10 Average DL signal strength. The signal (UL, DL) strength is given as value 0..63 (GSM 5.08)

. 0 =less than -110dBm, 1= -110 to -109 dBm, 3= -109 to -108dBm

. ... 62 = -49 to -48, 63=greater than -48

SAMPLE ABOVE :For Down link TX 1 and TX 2 have big differences , also for TX5

and TX6 for sec 2For Uplink RX main having 3db diff in sec 1, for sec 2 have 9 db

diff

Page 13: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 13/22

13 © Nokia Siemens Networks. All rights reserved.

Sample ND 232 ( Time advance)this site having overshoot issue

Page 14: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 14/22

14 © Nokia Siemens Networks. All rights reserved.

Sample ND 232this site having overshoot issue

Page 15: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 15/22

15 © Nokia Siemens Networks. All rights reserved.

AUDIT ANTENNA and Neighbors

Page 16: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 16/22

16 © Nokia Siemens Networks. All rights reserved.

Sample ND 153 ( handover)

• MancagarMD3 to CiropohMG2 and cisarunimg having 100% fail• MancagarMD3 to mancagar MG3 having 85 of 2144 sample call Fail• This report showing incoming and outgoing handover

Page 17: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 17/22

17 © Nokia Siemens Networks. All rights reserved.

Exception for 7745

• 7745 will keep occur for this condition :1. No have neighbors cell ( island or remote standalone)2. Landscape contour ( hill and valley)3. Obstacle

This exception need to be justify as long as the KPI value achieve

Page 18: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 18/22

18 © Nokia Siemens Networks. All rights reserved.

Summary

1. Alarm 7745 occur due to Abnormal release Channel

- Mostly in TCH 53,56,59 because of Handover, Call Setup Issue- SDCCH 4B because of antenna and feeder installation2. Module M6HA should be part of BTS High Capacity3. Correction related alarm 7745 software CX5 CD4 (replace CX4.1 CD4)4. Many things that can lead to alarm 7745, it can be categorized as below :

Transmission issue, Power Related issueEnvironment Related, Air Conditioning, TemperatureBTS HW problem related, Cooling Fan, Module faultyBTS Antenna LineCoverage Issue

Configuration Mismatch between BSC and BTS/MMISome existing problem in the old SWOther maintenance activity in the BSC level

Page 19: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 19/22

19 © Nokia Siemens Networks. All rights reserved.

RFI Site Procedure

Objective:1. To have better site integration verification procedure2. To make sure that all functionality of the integration site already

in place and being verified3. To avoid unnecessary mistake on integration such as cross feeder

(partial and full), Loose feeder and others functionalities.

Additional :

Page 20: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 20/22

20 © Nokia Siemens Networks. All rights reserved.

RFI Site Procedure Methodology:

There are 3 group of site check of this test call procedure:a. Connected Mode

- Mobile originated calls of voice services

b. Cross feeder Check1.Using Network Monitoring on TEMS/NEMO (for best result for recognizing cross feedersymptom, Move along main lobe of each cell ± 500 m, and make sure that we have theserving CI along the main lobe).

2.Make Test Call and notate the used TRX in case of Hopping TRX eg. (Synthesizer Hopping)Specific MAIO will represent specific transceiver according to system Configuration or Siteparameter. In case of Baseband Hopping TRXs then Baseband hopping parameter shall bedisable then individual test shall be carried out individually per TRX according to DatabaseSite parameter.

3.Lock the Transceiver carrying BCCH Frequency and perform test number 2 until all TRXs inthe same cell have been successfully verified

4.Locate the same treatment in the different sectors5.Failed TRXs can trigger further analysis with the site inspection on possible wrong

connection or swapped feeder/antennac. Hardware Inspection

- Antenna Type- Antenna azimuth- Antenna downtilt (Mechanical/Electrical)- Have feeder label and match with antenna

d. Remarks for further finding on the field

Page 21: 7745 Investigation Presentation(1)

8/11/2019 7745 Investigation Presentation(1)

http://slidepdf.com/reader/full/7745-investigation-presentation1 21/22

THINGS TO REMEMBER:

ND 195 : • Average /sector range is 3-5• Number of sample preferably >1000

ND 196 : • Focus result at q5, q6 and q7• UL and DL percentage should be ≥ 95

ND 232 : • Range (km)• Area (rural or urban)• Number of report (samples)

ND 153: • To fail = 0