NEC Pasolink IP & Setup Configuration Manual

Page 2: 75254175-NEC-Pasolink-IP-Setup-Configuration.pdf

2

Disclaimer

This Manual is for Wateen RAN P&D internal use only. No part of it can be copied or reproduced electronically or manually by any means without prior information from the department.

Page 3: 75254175-NEC-Pasolink-IP-Setup-Configuration.pdf

3

First we have to login to PNMT

User name: Admin Connection: Check Dialup Dialup Entry Name: PNMT (USB) And then click Login, following window will appear.

Page 4: 75254175-NEC-Pasolink-IP-Setup-Configuration.pdf

4

For any configuration on NEC we have to ON the option of Maintenance for it, for that we will go to MAINT option then turn ON the option for Maintenance, it will then turn in to yellow.

Note: Remember for Link panning we have to turn ON the Antenna Alignment mode as well along with Maintenance mode in similar manner.

Page 5: 75254175-NEC-Pasolink-IP-Setup-Configuration.pdf

5

IP Configuration: For IP configurations go to CRTL option as shown below,

It will then open a window shown below; we have to then click on option Equipment Network Setting.

Now we can have two scenarios here,

• NE • Root NE

Page 6: 75254175-NEC-Pasolink-IP-Setup-Configuration.pdf

6

• For NE select the CTRL Type Normal NE and then implement the IP Plan accordingly,

For Root NE select the CTRL Type Root NE and then implement the IP Plan.

Note: Don’t forget to click on Execute once you have implemented the IP Plan. After executing the IP Plan Link will automatically restart.

Page 7: 75254175-NEC-Pasolink-IP-Setup-Configuration.pdf

7

Setup Configuration: First go to Configuration option in main window Then Equipment Setup Then press Setup there Then press Configure there.(See below figure for the reference, All windows are opened. The options which we have to click are marked with Red small box)

We have to give here b/m settings,

• Redundancy Setting: If the link is 1+0 then we have to select option of 1+0(TERM) else we have to select 1+1(Hot standby)

• Main(Work) – INTFC: We have to select 4Port LAN with E1(VLAN) • LAN Port Usage: This option should be Port Shared • Radio Mapping: P1-P2-P3-P4=(Depends upon Link 40/100/150Mbps) • TX RF Freq: Insert the freq as per Link Budget. • Frame ID: It should be same on both ends • TX Power Control: MTPC

Note: See figures below for the reference how to insert the above things in software. All values below are imaginary; we have to insert them as per our LB and IP Plan. Don’t forget to execute after inserting all values.

Page 8: 75254175-NEC-Pasolink-IP-Setup-Configuration.pdf

8

Page 9: 75254175-NEC-Pasolink-IP-Setup-Configuration.pdf

9

By: Owais Faiz RAN P&D (South)