TC 3000 The technique behind the TC 3000 thermocoagulator? The principle of thermo coagulation is the heating of the vein which makes it coagulate. This rise in temperature is achieved by sending a high frequency pulse from the tip of a thin needle. Because the needle is insolated, the effect is very local and effects on the surrounding tissue is limited. Although the TC 3000 is also using a needle, thermo coagulation is profoundly different from electro coagulation. Electro coagulation provokes a chemical burn, is more painful and knows more side effects such as scarring. Precise control (generator) The duration of the pulse can be set from 0,1 to 1 seconds in 0,1 second steps. The pulse power can be selected in 5 % steps. The combination of both settings allow for very precise control over the amount of energy administered. THERMOCOAGULATOR 7451_F CARE_MED_TC 3000_071217.indd 1 7451_F CARE_MED_TC 3000_071217.indd 1 31-10-2008 11:10:47 31-10-2008 11:10:47

7451 F CARE MED TC 3000 071217€¦ · 77451_F CARE_MED_TC 3000_071217.indd 4451_F CARE_MED_TC 3000_071217.indd 4 331-10-2008 11:11:071-10-2008 11:11:07. Title: 7451_F CARE_MED_TC

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 7451 F CARE MED TC 3000 071217€¦ · 77451_F CARE_MED_TC 3000_071217.indd 4451_F CARE_MED_TC 3000_071217.indd 4 331-10-2008 11:11:071-10-2008 11:11:07. Title: 7451_F CARE_MED_TC

TC 3000

The technique behind the TC 3000 thermocoagulator?

The principle of thermo coagulation is the heating of the vein which makes it coagulate. This rise in temperature is achieved by sending a high frequency pulse from the tip of a thin needle. Because the needle is insolated, the eff ect is very local and eff ects on the surrounding tissue is limited. Although the TC 3000 is also using a needle, thermo coagulation is profoundly diff erent from electro coagulation. Electro coagulation provokes a chemical burn, is more painful and knows more side eff ects such as scarring.

Precise control (generator)The duration of the pulse can be set from 0,1 to 1 seconds in 0,1 second steps. The pulse power can be selected in 5 % steps. The combination of both settings allow for very precise control over the amount of energy administered.

THERMOCOAGULATOR

7451_F CARE_MED_TC 3000_071217.indd 17451_F CARE_MED_TC 3000_071217.indd 1 31-10-2008 11:10:4731-10-2008 11:10:47

Page 2: 7451 F CARE MED TC 3000 071217€¦ · 77451_F CARE_MED_TC 3000_071217.indd 4451_F CARE_MED_TC 3000_071217.indd 4 331-10-2008 11:11:071-10-2008 11:11:07. Title: 7451_F CARE_MED_TC

Safety (needle)Due to he use of insolated needles, only the tip of the needle is heated, so the skin will not be damaged. Therefore there are no depigmentation or burnstains. For every new treatment the settings of time and power of the impulse can be changed by the specialist. The two needles which have been developed especially for Thermocoagulation are the R3i and R6i. Each needle has it’s own specifi c properties. The R3i needle is suitable for the treatment of couperose on the face and the R6i needle is suitable for the veins situated on the legs.

Indications• Varicose veins (up to 0,9 mm diameter)• Couperose• Red dots

No side eff ects:Because of the constant and accurate controlable power and limited skin contact there are no burns, necrosis, scarring or pigmentation.

A TC 3000 session in 3 easy steps1. Desinfect skin2. Insert needle perpendicular in the vein3. Give energy puls every 2 to 3 mm

There are 2 preset programs: varicose veins and couperose.Result: treatment of 40 to 80 cm veins in 10 to 15 minutes.

Clinical Studies

Dr. Jean-Luc RichardFlebologist, Hopital Europeen GeorgesPompidou, Paris.

Dr. Jean-Marc ChardonneauFlebologist, Nantes.

7451_F CARE_MED_TC 3000_071217.indd 27451_F CARE_MED_TC 3000_071217.indd 2 31-10-2008 11:10:5031-10-2008 11:10:50

Page 3: 7451 F CARE MED TC 3000 071217€¦ · 77451_F CARE_MED_TC 3000_071217.indd 4451_F CARE_MED_TC 3000_071217.indd 4 331-10-2008 11:11:071-10-2008 11:11:07. Title: 7451_F CARE_MED_TC

Dr. Jean-Luc Richard has published the results of a clinical trial of the TC 3000 and thermo coagulation. The study showed that the new techniques for treating teleangiectasies is reliable and without lasting side eff ects. Several studies, done by Dr. Jean-Marc Chardonneau between march 1999 and january 2005, based on over 7000 sessions, confi rm:• eff ective for all vein problems, especially those with a diameter less then 0.9 mm which cannot

be treated with sclero compression therapy.• When following the correct protocol over 80 % of the veins are permanently removed.• Suitable for all skin types.• No side eff ects have been found, only temporarily micro scabs.• No pigmentation alterations, necrosis or burns

The Advantages

For patients• Very moderate pain; the treatment can be easily endured• No elastic stockings or bandages• Immediate result• No seasonal limitation due to sun exposure• Can be used on any skin photo type

For physicians• No complications• Easy to use• Direct result. Every vein typically needs only one treatment. Also on the legs• No allergic reaction• No pigmentation / discoloration• Can be used for all kinds of vein problems• All body parts, also the sensitive areas such as face, ankles and knees• On its own or as an addition to sclerotherapy (the fi nishing touch)• Eff ective and aff ordable. Very low maintenance cost

TC 3000 technical specifi cations• Generator HF: frequency 4 MHz• Adjustable voltage from 0 to 500 V in 5 % steps• Adjustable pulse duration from 0,1 to 1 second

7451_F CARE_MED_TC 3000_071217.indd 37451_F CARE_MED_TC 3000_071217.indd 3 31-10-2008 11:11:0231-10-2008 11:11:02

Page 4: 7451 F CARE MED TC 3000 071217€¦ · 77451_F CARE_MED_TC 3000_071217.indd 4451_F CARE_MED_TC 3000_071217.indd 4 331-10-2008 11:11:071-10-2008 11:11:07. Title: 7451_F CARE_MED_TC

Sizes and weightHeight: 16 cmDepth: 38 cmWidth: 53 cmWeigth: 5,5 kg

Power supplyVoltage: 115 to 230 voltFrequency: 50 to 60 HzPower: 55 VA

NeedlesR3i for the face (0.08 mm)R6i for the body (0.15 mm)

TC3000 needle

normal needle

DermaKare: Vitamine K oxydant creme for after veintreatment.

Kontichsesteenweg 54 • 2630 Aartselaar - Belgium • tel +32 3 451 51 45 • fax +32 3 451 51 [email protected] • www.fcaresystems.comD-COM-TC3E-03