16
600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com Bulletin 330-060 Page 1 2015 ENCLOSURE OPTIONS: 1) 0.125” #5052H32 Aluminum 2) 12-gauge #304L Stainless Steel Corrosion proof nameplate is located to provide easy access for the operator Door-holder rods are stainless steel and hold the doors open 100 degrees or 140 degrees Heavy duty 11-gauge steel enclosure is all-welded construction for long life Front or front and rear doors for easy access Nonferrous hardware for long life Stainless steel hinges are welded to the door and the enclosure – 0.375” pins are standard Cross-kinked roof prevents standing moisture Removable lift provisions with blind holes for tamper resistance Overlapping door and enclosure flanges - with other features - provide tamper resistance to meet national and regional standards Superlife finish includes phosphatizing, rust-inhibiting epoxy primer and Pad-Mount Green (Munsell 7GY 3.29/15) polyurethane top coat - over 5 mils dry Optional Color: Grey (Munsell 5BG 7.0/0.4) Ground lugs on each wall of the enclosure accept #6 - #2/0 ground cable Open bottom allows access for easy installation and maintenance Coordinated padlock and hex-head or optional penta-head bolt (top and bottom) provides bolted door security with visual confirmation by supervisory personnel. Security bolt is made captive with a stainless steel washer compressed to an oval shape to severely discourage removal.

600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 1 2015

ENCLOSURE OPTIONS:1) 0.125” #5052H32 Aluminum2) 12-gauge #304L Stainless Steel

Corrosion proof nameplateis located to provide easyaccess for the operator

Door-holder rods are stainlesssteel and hold the doors open100 degrees or 140 degrees

Heavy duty 11-gauge steel enclosure is all-welded construction for long life

Front or front and rear doors for easy access

Nonferroushardwarefor long life

Stainless steel hinges are welded to the door and the enclosure – 0.375” pins are standard

Cross-kinked roof prevents standing moisture

Removable lift provisions with blind holes fortamper resistance

Overlapping door andenclosure flanges - withother features - provide tamper resistance to meet national and regionalstandards

Superlife finish includes phosphatizing, rust-inhibiting epoxy primer and Pad-Mount Green (Munsell 7GY 3.29/15) polyurethane top coat - over 5 mils dryOptional Color: Grey(Munsell 5BG 7.0/0.4)

Ground lugs on each wall of the enclosure accept #6 - #2/0 ground cable

Open bottom allows access for easy installation and maintenance

Coordinated padlock and hex-head or optional penta-head bolt (top and bottom) provides bolted door security with visual confirmation by supervisory personnel. Security bolt is made captive with a stainless steel washer compressed to an oval shape to severely discourage removal.

Page 2: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 2 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

BottomOpen

Ø 0.75" Typical

5"

3" Min.

3" Min.

5"

13.375"

11"

14"

13.375"

14"11"

BA

A

B

"AA"

30" 24"

24"

30"

Anchor Bolt Locations

Ground lugson each wall

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

#2/0 Conductoraccept #6 to

Section BBand Typical Pad Dimensions

Section AAFront ViewDoor Removed

Front Access Only

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFA-ENCL-0.6-30W24D36H 36”

EPMFA-ENCL-0.6-30W24D42H 42”

EPMFA-ENCL-0.6-30W24D48H 48”

EPMFA-ENCL-0.6-30W24D54H 54”

Page 3: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 3 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

BottomOpen

Ø 0.75" Typical

5"

3" Min.

3" Min.

5"

16.375"

11"

17"

16.375"

17"11"

BA

A

B

"AA"

36" 24"

24"

36"

Ground lugson each wall

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

#2/0 Conductoraccept #6 to

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront ViewDoor Removed

Front Access Only

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFA-ENCL-0.6-36W24D36H 36”

EPMFA-ENCL-0.6-36W24D42H 42”

EPMFA-ENCL-0.6-36W24D48H 48”

EPMFA-ENCL-0.6-36W24D54H 54”

Page 4: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 4 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

11"

3" Min.

3" Min.

11"

19.375"

17"

20"

19.375"

20"17"

BA

A

B

"AA"

42" 36"

36"

42"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront ViewDoor Removed

Front Access Only

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFA-ENCL-0.6-42W36D36H 36”

EPMFA-ENCL-0.6-42W36D42H 42”

EPMFA-ENCL-0.6-42W36D48H 48”

EPMFA-ENCL-0.6-42W36D54H 54”

Page 5: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 5 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

14"

3" Min.

3" Min.

14"

22.375"

20"

23"

22.375"

23"

20"

BA

A

B

"AA"

48" 42"

42"

48"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront ViewDoor Removed

Front Access Only

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFA-ENCL-0.6-48W42D36H 36”

EPMFA-ENCL-0.6-48W42D42H 42”

EPMFA-ENCL-0.6-48W42D48H 48”

EPMFA-ENCL-0.6-48W42D54H 54”

Page 6: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 6 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

14"

3" Min.

3" Min.

14"

25.375"

20"

26

25.375"

26"20"

BA

A

B

"AA"

54" 42"

42"

54"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront ViewDoors Removed

Front Access Only

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFA-ENCL-0.6-54W42D36H 36”

EPMFA-ENCL-0.6-54W42D42H 42”

EPMFA-ENCL-0.6-54W42D48H 48”

EPMFA-ENCL-0.6-54W42D54H 54”

Page 7: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 7 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

14"

3" Min.

3" Min.

14"

28.375"

20"

29"

28.375"

29"20"

BA

A

B

"AA"

60" 42"

42"

60"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront ViewDoors Removed

Front Access Only

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFA-ENCL-0.6-60W42D36H 36”

EPMFA-ENCL-0.6-60W42D42H 42”

EPMFA-ENCL-0.6-60W42D48H 48”

EPMFA-ENCL-0.6-60W42D54H 54”

Page 8: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 8 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Ø 0.75" Typical

11"

3" Min.

3" Min.

11"

16.375"

17"

17"

16.375"

17"17"

BA

A

B

"AA"

36" 36"

36"

36"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

BottomOpen

Section BBand Typical Pad Dimensions

Section AAFront & Rear ViewNearest Door Removed

Front & Rear Access

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFRA-ENCL-0.6-36W36D36H 36”

EPMFRA-ENCL-0.6-36W36D42H 42”

EPMFRA-ENCL-0.6-36W36D48H 48”

EPMFRA-ENCL-0.6-36W36D54H 54”

Page 9: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 9 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

14"

3" Min.

3" Min.

14"

19.375"

20"

20"

19.375"

20"

20"

BA

A

B

"AA"

42" 42"

42"

42"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront & Rear ViewNearest Door Removed

Front & Rear Access

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFRA-ENCL-0.6-42W42D36H 36”

EPMFRA-ENCL-0.6-42W42D42H 42”

EPMFRA-ENCL-0.6-42W42D48H 48”

EPMFRA-ENCL-0.6-42W42D54H 54”

Page 10: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 10 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

17"

3" Min.

3" Min.

17"

22.375"

23"

23"

22.375"

23"

23"

BA

A

B

"AA"

48" 48"

48"

48"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront & Rear ViewNearest Door Removed

Front & Rear Access

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFRA-ENCL-0.6-48W48D36H 36”

EPMFRA-ENCL-0.6-48W48D42H 42”

EPMFRA-ENCL-0.6-48W48D48H 48”

EPMFRA-ENCL-0.6-48W48D54H 54”

Page 11: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 11 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

20"

3" Min.

3" Min.

20"

25.375"

26"

26"

25.375"

26"

26"

BA

A

B

"AA"

54" 54"

54"

54"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront & Rear ViewNearest Doors Removed

Front & Rear Access

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFRA-ENCL-0.6-54W54D36H 36”

EPMFRA-ENCL-0.6-54W54D42H 42”

EPMFRA-ENCL-0.6-54W54D48H 48”

EPMFRA-ENCL-0.6-54W54D54H 54”

Page 12: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 12 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

20"

3" Min.

3" Min.

20"

28.375"

26"

29"

28.375"

29"

26"

BA

A

B

"AA"

60" 54"

54"

60"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront & Rear ViewNearest Doors Removed

Front & Rear Access

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFRA-ENCL-0.6-60W54D36H 36”

EPMFRA-ENCL-0.6-60W54D42H 42”

EPMFRA-ENCL-0.6-60W54D48H 48”

EPMFRA-ENCL-0.6-60W54D54H 54”

Page 13: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 13 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

23"

3" Min.

3" Min.

23"

34.375"

29"

35"

34.375"

35"

29"

BA

A

B

"AA"

72" 60"

60"

72"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront & Rear ViewNearest Doors Removed

Front & Rear Access

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFRA-ENCL-0.6-72W60D36H 36”

EPMFRA-ENCL-0.6-72W60D42H 42”

EPMFRA-ENCL-0.6-72W60D48H 48”

EPMFRA-ENCL-0.6-72W60D54H 54”

Page 14: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 14 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

29"

3" Min.

3" Min.

29"

37.375"

35"

38"

37.375"

38"

35"

BA

A

B

"AA"

78" 72"

72"

78"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Provision for Padlock andSecurity Bolt, Top and Bottom

CL

CL

Anchor Bolt Locations

Section BBand Typical Pad Dimensions

Section AAFront & Rear ViewNearest Doors Removed

Front & Rear Access

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFRA-ENCL-0.6-78W72D36H 36”

EPMFRA-ENCL-0.6-78W72D42H 42”

EPMFRA-ENCL-0.6-78W72D48H 48”

EPMFRA-ENCL-0.6-78W72D54H 54”

Page 15: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 15 2015

Galv. Square

1.5"

BoltsAnchorØ.5"Enclosure Washer

2.25" X 2.25"

Bracket

1.5"

#6102-A81-7

Elliott Anchor

BoltsAnchorØ.5"Enclosure

Concrete Pad

Concrete Pad

Alternate #2

Alternate #1

Bottom Open

Ø 0.75" Typical

CL

CL

29"

3" Min.

3" Min.

29"

40.375"

35"

41"

40.375"

41"

35"

BA

A

B

"AA"

84"

72"

84"

Provision for Padlock andSecurity Bolt, Top and Bottom

Anchor Bolt Locations

72"

Ground lugs oneach wall accept

#6 to #2/0 Conductor

Section BBand Typical Pad Dimensions

Section AAFront & Rear ViewNearest Doors Removed

Front & Rear Access

When additional enclosure height is required, a 60” or 66” high enclosure can be supplied. To order a 60” high enclosure, change the “-54H” portion of the catalog number to “-60H”. To order a 66” high enclosure, change the “-54H” portion of the catalog number to “-66H”.

Catalog Number Dim. “AA”

EPMFRA-ENCL-0.6-84W72D36H 36”

EPMFRA-ENCL-0.6-84W72D42H 42”

EPMFRA-ENCL-0.6-84W72D48H 48”

EPMFRA-ENCL-0.6-84W72D54H 54”

Page 16: 600-Volt Secondary Enclosure Pad-Mounted - Elliott Industrieselliott-industries.com/eipdf/b330-060.pdf · 600-Volt Secondary Enclosure Pad-Mounted – Outdoor Elliott Industries,

600-Volt Secondary Enclosure Pad-Mounted – Outdoor

Elliott Industries, Inc. 1509 Hamilton Road Bossier City, LoUiSiAna 71111 [email protected] © Copyright 2015 Phone 318-746-3296 Fax 318-741-1127 www.elliott-industries.com

Bulletin

330-060Page 16 2015

600-Volt Pad-Mounted ─ Outdoor Secondary Enclosures are available in other sizes.If you do not find the size that fits your need, please contact our representative or the factory.

Typical Specification

General The pad-mounted secondary equipment enclosure shall be 600 volt class, designed to house electrical equipment that is energized at no more than 600 volts to ground (nor 1000 volts phase to phase). Tamper resistance shall meet the Enclosure Security requirements of IEEE Standard C57.12.28 (Pad-Mounted Equipment—Enclosure Integrity) to resist unauthorized entry, protect authorized and unauthorized persons, and provide positive safety features when installed in areas accessible to the general public. The enclosure shall be constructed for outdoor installation in areas subject to heavy precipitation and in areas of windblown contamination. The enclosure shall be completely assembled prior to shipment.

Enclosure ConstructionThe enclosure shall be tamper-resistant, all-welded

construction utilizing 11-gauge minimum sheet steel. Corner plates and braces shall be used as necessary to assure rigidity. The enclosure top shall be cross-kinked to provide watershed and rigidity. The enclosure shall be open bottom with a 1-inch flange inside, all around. The door(s) shall be furnished with a stainless steel door holder that will latch the door open 100 degrees and 140 degrees and resist accidental closing. Door(s) shall be provided with provisions for padlocking and a recessed hex-head (or penta-head) security bolt to prevent unauthorized entry (coordinated to prevent installation of the padlock until the security bolt is tightened when closing the door(s) and to prevent a wrench from operating the security bolt until the padlock is removed when opening the door(s)). The security bolt shall be made captive with a stainless steel washer compressed to an oval shape to severely discourage removal. Hinges shall be stainless steel (with stainless steel pins not less than 0.3125-inch diameter) and shall be welded to both the enclosure and the door(s) to maintain door alignment for the life of the equipment. The enclosure shall be nonventilated to minimize the entrance of airborne contamination, insects, rodents or reptiles. The protective finish shall include necessary grinding, cleaning and phosphatizing, two-component rust-inhibiting epoxy primer and a Pad-Mount Green two-component polyurethane top coat finish (Munsell color 7GY 3.29/1.5). The primer and top coat shall be electronically monitored during application to insure proper ratio and mixing of each component. Total average thickness of paint (after curing) shall be not less

than 5 mils. The protective coating shall meet the Enclosure Coating System requirements of IEEE Standard C57.12.28 (Pad-Mounted Equipment—Enclosure Integrity). Removable lift provisions, adequate to withstand handling with normal utility equipment, shall be provided on the outside of the enclosure. Threaded openings for lift provision bolts shall be blind holes to prevent the entrance of wire or other foreign objects into the enclosure when lift provisions are removed.

Grounding Provisions Two high-conductivity bronze eyebolt-type ground lugs, which accept #6 through #2/0 copper conductor, shall be installed on the inside walls of the enclosure (located on each side of each door opening in an accessible position as shown on the drawings).

Accessory Equipment A corrosion proof nameplate with permanent thermal transfer printing shall be installed inside one enclosure door. It shall be located at the top corner farthest from the enclosure when the door is open. The nameplate will provide Type of Equipment, Model Number, Amps Continuous, kV Maximum, BIL, Serial Number, Job Number, Date Manufactured and Weight of Equipment. When specified, one “Warning - Keep Out! - Hazardous Voltage” sign, Elliott #7201-W2003-316, shall be provided on the outside of each door. When specified, four anchor-bolt brackets, Elliott #6102-A81-7 or approved equal, shall be supplied with each secondary enclosure to provide a means of clamping the equipment to the concrete pad.

Packaging Each enclosure shall be bolted to a solid-top wood pallet (to prevent the forks of a forklift truck from entering the open bottom of the equipment) to prevent hidden damage. The equipment shall be wrapped with 0.125-inch thick polyethylene foam or other suitable material to minimize damage to the finish during shipment.

DrawingsWhen specified, drawings shall be furnished for each

enclosure that include:1) enclosure dimensions and location of components.2) proposed pad dimensions and location of anchor

bolts.