Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577 Request for Price Quote & Statement of Work Date 05-06-2013 SOW # 286 TSR # T.B.D. Order # T.B.D. Project name: Shapero Hall Rewire Project Building number/name 050 - Shapero Hall Building Building address: 5501 Gullen Mall Number of floors/involved : 3 New IDF on 1 floor. Not Assigned On Prints Prints Supplied yes Form submitted by: Pete Garabedian Work to be Completed By: Walk through date/time: Date Quote Response due back to WSU: Note: Please return all floor plans with your Bid Response/Proposal: Bidder information Company name: Address: City: State: MI Zip: Person submitting Quote: Position: Tel # Fax # e-mail Walk-thru Attendees: Description of Work Requested by WSU All work shall conform to Wayne State University Standards for Communications Infrastructure and Specifications dated October 31, 2012 which can be reviewed & downloaded at: http://www.computing.wayne.edu/docs/wsu-communications-standards.pdf Details & clairifications will be discussed at the mandatory prebid meeting Bid requirements: 1) Pricing detail must be filled out completely, or this price quote will not be accepted. 2) RCDD person on full time payroll to manage the on onsite installation of this project 3) All pre bid, bid & bid award processes will include at least 1 person from WSU’s /C&IT’s IT Customer Services Group, College of Liberal Arts & Sciences IT & WSU project manager. Description WSU needs to replace the old CAT 3 & CAT 5 voice/data cabling at Shapero Hall building # 050. This amounts to installing 51 dual voice/data jacks at locations shown on the spread sheet & prints circled in red. In addition to this, the installation contractor will move and cross connect the voice lines from the old jack to the new jack in the MDF and IDFs to the new horizontal cable. This will require a coordinated cutover with WSU project manager. This will include at a minimum of one IT person from College of Liberal Arts & Sciences, C&IT network engineering & telecommunications departments. WSU Electronic Technicians will connect the data patch panel ports to the network switches. All of the old voice and data cabling must be removed from the jack back to the communication room after the voice & data cutover is completed. Horizontal Cabling In the basement install 1 dual voice/data jacks per office or lab room at locations listed in the ShaperoHall_Location_Spreadsheet.xlsx provided. Jack locations shown on the print. This amounts to a total of 4 dual voice/data jacks. Voice & data terminates on seperate patch panels in the communication rack. All basement connections terminate in communication room 016.1. On the 2nd Floor install 1 dual voice/data jacks per office or lab room at locations listed in the 2nd_ShaperoHall_Location_Spreadsheet.xlsx provided. Jack locations shown on the print. This amounts to a total of 11 dual voice/data jacks. Voice & data terminates on seperate patch panels in the communication rack. All 2nd floor connections terminate in basement communication room 016.1. On the 3rd Floor install 1 dual voice/data jacks per office or lab room at locations listed in the 3rd_ShaperoHall_Location_Spreadsheet.xlsx provided. Jack locations shown on the print. This amounts to a total of 23 dual voice/data jacks. Voice & data terminates on seperate patch panels in the communication rack. All 3rd floor connections terminate in 3rd floor communication room 315 or a new IDF built to service floors 3 & 4 TBD. On the 4th Floor install 1 dual voice/data jacks per office or lab room at locations listed in the 4th_ShaperoHall_Location_Spreadsheet.xlsx provided. Jack locations shown on the print. This amounts to a total of 13 dual voice/data jacks. Voice & data terminates on seperate patch panels in the Data terminates on a patch panel in the communication rack. 3rd floor connections terminate in communication rack. All 4th floor connections terminate in 3rd floor communication room 315 or a new IDF built to service floors 3 & 4 TBD. Page 1

5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577

Computing & Network Services 5925 Woodward – Detroit, MI 48202Tel. 313- 577-1955 Fax 313-577-5577

Request for Price Quote & Statement of Work Date 05-06-2013SOW # 286

TSR # T.B.D.Order # T.B.D.

Project name: Shapero Hall Rewire Project Building number/name 050 - Shapero Hall BuildingBuilding address: 5501 Gullen MallNumber of floors/involved : 3 New IDF on 1 floor. Not Assigned On Prints Prints Supplied yesForm submitted by: Pete Garabedian Work to be Completed By: Walk through date/time: Date Quote Response due back to WSU: Note: Please return all floor plans with your Bid Response/Proposal:

Bidder informationCompany name: Address: City: State: MI Zip: Person submitting Quote: Position: Tel # Fax # e-mailWalk-thru Attendees:

Description of Work Requested by WSU

All work shall conform to Wayne State University Standards for Communications Infrastructure and Specifications dated October 31, 2012 which can be reviewed & downloaded at:

http://www.computing.wayne.edu/docs/wsu-communications-standards.pdf Details & clairifications will be discussed at the mandatory prebid meeting Bid requirements:1) Pricing detail must be filled out completely, or this price quote will not be accepted. 2) RCDD person on full time payroll to manage the on onsite installation of this project 3) All pre bid, bid & bid award processes will include at least 1 person from WSU’s /C&IT’s IT Customer Services Group, College of Liberal Arts & Sciences IT & WSU project manager.

DescriptionWSU needs to replace the old CAT 3 & CAT 5 voice/data cabling at Shapero Hall building # 050. This amounts to installing 51 dual voice/data jacks at locations shown on the spread sheet & printscircled in red. In addition to this, the installation contractor will move and cross connect the voice linesfrom the old jack to the new jack in the MDF and IDFs to the new horizontal cable. This will require acoordinated cutover with WSU project manager. This will include at a minimum of one IT person from

College of Liberal Arts & Sciences, C&IT network engineering & telecommunications departments.WSU Electronic Technicians will connect the data patch panel ports to the network switches. All of theold voice and data cabling must be removed from the jack back to the communication room after the voice & data cutover is completed. Horizontal Cabling In the basement install 1 dual voice/data jacks per office or lab room at locations listed in the ShaperoHall_Location_Spreadsheet.xlsx provided. Jack locations shown on the print. This amountsto a total of 4 dual voice/data jacks. Voice & data terminates on seperate patch panels in thecommunication rack. All basement connections terminate in communication room 016.1.

On the 2nd Floor install 1 dual voice/data jacks per office or lab room at locations listed in the 2nd_ShaperoHall_Location_Spreadsheet.xlsx provided. Jack locations shown on the print. This amountsto a total of 11 dual voice/data jacks. Voice & data terminates on seperate patch panels in thecommunication rack. All 2nd floor connections terminate in basement communication room 016.1.

On the 3rd Floor install 1 dual voice/data jacks per office or lab room at locations listed in the 3rd_ShaperoHall_Location_Spreadsheet.xlsx provided. Jack locations shown on the print. This amountsto a total of 23 dual voice/data jacks. Voice & data terminates on seperate patch panels in thecommunication rack. All 3rd floor connections terminate in 3rd floor communication room 315 or a new IDF built to service floors 3 & 4 TBD.

On the 4th Floor install 1 dual voice/data jacks per office or lab room at locations listed in the 4th_ShaperoHall_Location_Spreadsheet.xlsx provided. Jack locations shown on the print. This amountsto a total of 13 dual voice/data jacks. Voice & data terminates on seperate patch panels in theData terminates on a patch panel in the communication rack. 3rd floor connections terminate incommunication rack. All 4th floor connections terminate in 3rd floor communication room 315 or a newIDF built to service floors 3 & 4 TBD.

Page 1

Page 2: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577
Page 3: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577
Page 4: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577
Page 5: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577
Page 6: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577
Page 7: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577

                                                                                   Wayne State University Substandard Communication Cabling Building Audit Spreadsheet

Building Name Building Number FloorRoom Number Jack Number

Jack & Cable 

Category

Number Of Working Phones Notes/Comments

Shapero Hall 050 BSM 011 065 cat3 1 V/DBSM 018 N/A cat5 1 V/D room locked  maintence supv.BSM 100 100.2 cat5 1BSM 100 049 cat32nd 206 no label cat32nd 206 no label cat32nd 206 no label cat32nd 200 200 cat52nd 200.4 no label cat32nd 204 no label cat5 12nd 204 no label cat32nd 205 no label cat3 12nd 200.1 no label cat3 12nd 200.5 no label cat32nd 202 no label cat33rd 316 316 cat53rd 314 no label cat33rd 314 314 cat53rd 306 060 cat33rd 306.2 062 cat3 13rd 319 no label cat33rd 317 voice 6 cat53rd 317 data 6 cat53rd 317 can't see cat5 V/D3rd 317 can't see cat5 V/D3rd 317 can't see cat5 V/D3rd 317 can't see cat5 V/D3rd 317 can't see cat5 1 V/D

Page 8: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577

Totals 27

Page 9: 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313 … · 2013-07-17 · Computing & Network Services 5925 Woodward – Detroit, MI 48202 Tel. 313- 577-1955 Fax 313-577-5577

                                                                                   Wayne State University Substandard Communication Cabling Building Audit Spreadsheet

Building Name Building Number FloorRoom Number Jack Number

Jack & Cable 

Category

Number Of Working Phones Notes/Comments

Shapero Hall 050 3rd 317 can't see cat5 1 V/D fax3rd 317 can't see cat5 V/D3rd 317 can't see cat5 V/D3rd 317 can't see cat5 V/D3rd 317 1 cat5 V/D3rd 317 2 cat5 V/D3rd 317 3 cat5 V/D3rd 307 cat3 V/D3rd 302 cat5 36PC's, teacher station, printer‐ see print‐ patched to 3rd 302 047 cat3 switch4th 403 034 cat3 V/D4th 404.1 030 cat3 1 V/D4th 404 404 cat54th 404 no label cat3 V/D4th 404.2 no label cat3 V/D4th 405 no label cat3 V/D4th 405 405 cat5 V/D4th 411 no label cat3 V/D4th 409 no label cat3 V/D4th 415 415 cat54th 415.1 no label cat3 V/D4th 410.4 038 cat3 V/D4th 410.1 040 cat3

Totals 22